Loading...
HomeMy WebLinkAboutARB201900058 Plan - Submittal (First) 2019-12-31 (2)�T 0. PARAPET (TOWER) 38'-4" HIGH EVE __-_-- 34'-7 1/4" LOW EVE ® 31'-4»---- 3RD LEVEL ABOVE GRA 21'-4»------ 2ND LEVEL ABOVE GRA 10'-8" 1ST LEVEL ABOVE GRAL 00'-0" GRADE PLANE UPPER BASEMENT LEVE ® L 0 WER BASEMENT LEVE -2l'_8" J � I vL/1\ 1 1 1 LLL V /-1 l IL/1 v SCALE: 1/8"= 1" 0" TO. PARAPET (TOWER) 48'-4„ HIGH EVE ----- - - - - -- 34'- 7 1/4" LOW EVE --------- 31'-4" 3RD LEVEL ABOVE GRADE 2ND LEVEL ABOVE GRADE - 10'-8" - METAL PANEL VENEER COLUMNS AND CAN( COLOR ASH GRAY 1ST LEVEL ABOVE GRADE - oo'-o" --- - - - - - - GRADE PLANE - -5'-9 1/2" UPPER_ BASEMENT LEVELok -11'-0" II II II II II II II II II LOWER_ BASEMENT LEVEL -21 '-8» --------------------------------------------------------------------------------------------------- - �-�-- MATERIAL LEGEND INSULATED METAL PANEL VENEER (KINGSPAN OPTIMO SMOOTH PANEL OR EQUAL, COLOR, LIGHT STONE ON 6" METAL STUD FRAMING. INSULATION BETWEEN STUDS TO BE 6" R-19 BATT INSULATION WITH VINYL FACE INSTALLED FACING INTERIOR 478716" GROUND FACED CONCRETE BLOCK VENEER ( MARTINSVILLE #9316 OR EQUAL ) WITH 2" AIR SPACE AND WALL TIES AS REQUIRED ON BULDING WRAP (COMMERCIAL GRADE TYVEK OR EQUAL) MECHANICALL Y FASTENED WITH CAP HEADED FASTENERS TO EXTERIOR GRADE GYPSUM SHEATHING ON 6" METAL STUD FRAME INSULATION BETWEEN STUDS TO BE 6" R-19 BATT INSULATION WITH VINYL FACE INSTALLED FACING INTERIOR BRICK VENEER (RIVERSIDE BRICK, BAYSTONE) WITH 2" AIR SPACE AND WALL TIES AS REQUIRED ON BULDING WRAP (COMMERCIAL GRADE TYVEK OR EQUAL) MECHANICALL Y FASTENED WITH CAP HEADED FASTENERS TO EXTERIOR GRADE GYPSUM SHEATHING ON 6" METAL STUD FRAME INSULATION BETWEEN STUDS TO BE 6" R-19 BATT INSULATION WITH VINYL FACE INSTALLED FACING INTERIOR BRICK VENEER (RIVERSIDE BRICK, RED VELOUR) WITH 2" AIR SPACE AND WALL TIES AS REQUIRED ON BULDING WRAP (COMMERCIAL GRADE TYVEK OR EQUAL) MECHANICALLY FASTENED WITH CAP HEADED FASTENERS TO EXTERIOR GRADE GYPSUM SHEATHING ON 6"' METAL STUD FRAME INSULATION BETWEEN STUDS TO BE 6'" R-19 BATT INSULATION WITH VINYL FACE INSTALLED FACING INTERIOR EXTERIOR STOREFRONT NOTES 1. DOORS TO BE NARROW STYLE,MS LOCK HARDWARE, TUBULAR PUSH/PULL HARDWARE, NORTON CLOSER W/ BACK CHECK & DOOR SWEEPS 2. FRAMES TO BE BRUSHED ALUMINUM FINISH J. ALL HARDWARE TO HAVE FINISHES TO MATCH FRAMES J. GLAZING TO BE LOW—E, 1" INSULATED. 4. GLAZING TO BE TINTED. VLT SHALL NOT BE BELOW 407 VLR SHALL NOT EXCEED 309' 5. GLAZING TO HAVE MAXIMUM TESTED SHGC OF OF .35 AND MAXIMUM TESTED U—FACTOR OF .35 SCALE: 1/8"= l' 0" GM F+A'a9OCIATE 4356 BONNEY ROAD BUILDING 3, SUITE 102 VIRGINIA BEACH, VA 23452 (757) 498-9800 WENTE; www.gmfplus.com EIP"RELM NARY= NOT FUR CONSTRUCTM DA TE REVISIONS ELEVATION SHEET A —2, / DATE : DECEMBER, 2019 SCALE : AS NOTED DRAWN : BMA, CLE CHECKED BY: CLE.