Loading...
HomeMy WebLinkAboutSDP201900056 Other 2020-01-02 (4)ELECTRICAL LEGEND: 0 V X 4' SURFACE MOUNTED LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE 1 TYPE. 82 WALL MOUNTED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE. GFI DUPLEX RECEPTACLE, 20A, 120V. INSTALL +18" A.F.F., U.O.N. TO TOP OF RECEPTACLE, U.O.N. IS CENTER SHADED, INSTALL +6" ABOVE SINK, COUNTERTOP OR BACKSPLASH. "GFI" WHEN USED INDICATES GROUND FAULT CIRCUIT INTERRUPTER. ELECTRICAL CONNECTION TO EQUIPMENT. EF ELECTRICAL CONNECTION TO EXHAUST FAN. Q JUNCTION BOX - SIZE AS REQUIRED. ® PANELBOARD, 208Y/120 VOLT. PANELBOARD, 480Y/277 VOLT. BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICK MARKS INDICATES 2 #12 CONDUCTORS AND 1 #12 GND., IN 1/2" CONDUIT, U.O.N. TICK MARKS, WHEN SHOWN, INDICATE NUMBER OF CONDUCTORS IF OTHER THAN THREE: (7) INDICATES GROUNDING CONDUCTOR. FH-20 P. HOMERUNS TO PANEL. PANEL AND CIRCUIT DESIGNATIONS AS INDICATED. GENERAL NOTES: 1. WHERE INDIVIDUAL 120V HOMERUN CIRCUITS ARE SHOWN ON THE DRAWINGS THEY MAY BE COMBINED AS FOLLOWS; - NO MORE THAN THREE (3) PHASE CONDUCTORS PLUS THREE (3) NEUTRAL AND ONE (1) GROUND PER CONDUIT, EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. - NO TWO OF THE SAME PHASE CONDUCTOR PER CONDUIT. - PROVIDE 120V CIRCUITS WITH INDIVIDUAL NEUTRALS PER CIRCUIT. NEUTRALS MAY NOT BE SHARED BETWEEN PHASES. 2. PAINT ALL EXPOSED CONDUIT TO MATCH THE SURFACE TO WHICH ATTACHED IF THE SURFACE IS PAINTED. 3. COORDINATE WITH MECHANICAL DRAWINGS FOR EXACT LOCATION OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS INCLUDING EXACT POINT OF ELECTRICAL CONNECTION. MAKE ADJUSTMENTS TO CONDUIT ROUTING, PLACEMENT OF DISCONNECTS AND STARTERS AS REQUIRED. 4. PROVIDE NEW TYPED PANEL INDEX CARDS IN EXISTING PANELBOARDS WHERE CIRCUITS HAVE BEEN MODIFIED BY THIS PROJECT. PROVIDE COPIES OF MODIFIED PANEL INDEX CARDS ON AS -BUILT DRAWINGS AND INCLUDE IN OPERATION AND MAINTENANCE MANUALS. 5. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE CONSTRUED TO MEAN CONDUIT AND CONDUCTORS. 6. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE THE POWER OUTAGE REQUIRED TO PERFORM ALL WORK, COORDINATE WITH THE OWNER'S REPRESENTATIVE AND VIRGINIA ENERGY IF REQUIRED PRIOR TO BEGINNING ANY WORK. Q CONSTRUCTION NOTE INDICATOR. S2M 20A, 2 POLE, MOTOR RATED SWITCH IN WEATHERPROOF ENCLOSURE. SM30 SINGLE POLE, 30A MOTOR RATED SNAP SWITCH. ABBREVIATIONS: SOS WALL SWITCH WITH OCCUPANCY SENSOR, SENSOR SWITCH CATALOG NUMBER WSD-PDT, OR A AMPERE EQUAL. A.F.F. ABOVE FINISHED FLOOR WH ELECTRICAL CONNECTION WATER HEATER. EF EXHAUST FAN ❑j 3P 40 3R DISCONNECT SWITCH, 240V, U.O.N.: 3P=NUMBER OF POLES, 60=SWITCH RATING, 40=FUSE RATING. PROVIDE IN NEMA 3R ENCLOSURE. EWH ELECTRIC WALL HEATER Of FOOTCANDLE INDICATOR. KVA KILOVOLT -AMPERE MCB MAIN CIRCUIT BREAKER MTD MOUNTED NO. NUMBER 0 PHASE U.O.N. UNLESS OTHERWISE NOTED W WIRE WH WATER HEATER WP WEATHERPROOF FLOOR PLAN - ELECTRICAL - LIGHTING SCALE: 1 /4" = V-0" FLOOR PLAN - ELECTRICAL - POWER SCALE: 1 /4" = V-0" LIGHT FIXTURE SCHEDULE TYPE MANUFACTURER'S CATALOG No. VOLT L LUMENS MOUNTING REMARKS 1 PHILIPS DAY-BRITE 1SML-32L840-4-FA-12F-UNV-DIM UNV LED - 3200 LUMENS 39 WATTS SURFACE SEE NOTE 1 2 STONCO LPW16-30-NW-G3-4-120-PCB-BK 120 LED - 3364 LUMENS 34.3 WATTS SURFACE/WALL SEE NOTE 2 LIGHT FIXTURE SCHEDULE NOTES: GENERAL: 1. MATCH MOUNTING HARDWARE AND FRAME WITH THE CEILING TYPE OR CONSTRUCTION IN WHICH FIXTURE IS TO BE INSTALLED, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS AND FINISH SCHEDULES. 2. FIXTURE SHALL HAVE A LLF (LIGHT LOSS FACTOR) OF 1.0 AND BE A FULL CUTOFF TYPE. CKT NO LOCATION: MOUNTING: Surface NEMA: Type 1 LOAD SERVED P C/B TRIP WIRE SIZE PANEL: FH VOLTS: 120/208 Wye PHASES: 3 WIRES: 4 PHASE A PHASE B PHASE C (AMPS) (AMPS) (AMPS) WIRE SIZE C/B TRIP KAIC RATING: MAINS TYPE: MAINS RATING: P 10 MCB 100 A LOAD SERVED CKT NO 1 Lighting 1 20 12 1.6 3.0 12 20 1 Receptacle 2 3 Exterior Lighting 1 20 12 3.0 3.0 12 20 1 Receptacle 4 5 Receptacle 1 20 12 3.0 10.0 12 20 1 Refrigerator 6 7 Receptacle Receptacle EWH EF-1 1 20 12 4.0 4.0 12 20 1 Receptacle EWH EWH UH-A 8 9 1 20 12 4.0 12.5 12 20 1 10 11 1 20 12 12.5 12.5 12 20 1 12 13 1 20 12 3.4 15.9 12 20 2 14 15 Water Heater 1 30 10 25.0 15.9 16 17 Spare HAND DRYER GRINDER PUMP Spare Spare 1 20 -- 0.0 2.0 12 20 1 TIME CLOCK 18 19 1 20 12 16.0 16.0 12 20 1 HAND DRYER Space Space 20 21 2 20 12 13.2 0.0 -- -- -- 22 23 13.2 0.0 -- -- -- 24 25 1 20 -- 0.0 0.0 -- -- -- Space 26 27 1 20 -- 0.0 0.0 -- -- -- Space 28 29 Spare 1 20 -- 0.0 0.0 -- -- -- Space 30 CONNECTED LOAD (AMPS): CONNECTED LOAD (KVA): 63 A 74 A 51 A 7 kVA 9 kVA 6 kVA TOTAL CONNECTED LOAD (KVA): 22 kVA TOTAL ESTIMATED DEMAND LOAD (KVA): 22 kVA NOTES: - 11 ELECTRICAL POWER RISER DIAGRAM NOT TO SCALE CONSTRUCTION NOTES: (THIS DRAWING ONLY) 1❑ EXISTING PANEL "A" IS A G.E. TYPE 'A' SERIES, 225 AMP MAIN CIRCUIT BREAKER, 480Y/277V, 3 PHASE, 4 WIRE. PROVIDE A 45A-3P CIRCUIT BREAKER IN BLANK SPACES TO SERVE NEW TRANSFORMER "FH". 2❑ PROVIDE TIME CLOCK "T/C", INTERMATIC TYPE "ET1105C" OR APPROVED EQUAL. PROVIDE WITH FORM R6 RELAYS. 3❑ PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT FROM TIME CLOCK TO EXHAUST FAN. COORDINATE ALL WORK WITH MECHANICAL SUB -CONTRACTOR. ® PROVIDE A 30KVA NEMA 3R TRANSFORMER, 480-208Y/120V. INSTALL ON BACK OF DUGOUT. 5❑ PROVIDE 3 #8 AND 1 #10 GROUND IN 3/4" CONDUIT. TERMINATE IN NEW 45A-3P CIRCUIT BREAKER INDICATED BY NEW WORK NOTE 1. © PROVIDE 4 #3 AND 1 #8 GROUND IN 1-1/4" CONDUIT. �7 PROVIDE 4 #3 AND 1 #8 GROUND IN 1-1/4" CONDUIT. BURY CONDUIT 24" BELOW GRADE. ® SEE ARCHITECTURAL DRAWINGS FOR EXACT MOUNTING HEIGHT. 9❑ PROVIDE STEM ACCESSORY LENGTH AS REQUIRED TO PENDANT MOUNT LIGHT FIXTURE 7'-6" A. F.F. 10 PROVIDE 100A-3P, 208V, NEMA-3R, "FDS". 11 PROVIDE #8 GROUNDING ELECTRODE CONDUCTORS TO A 3-3/4" X 10', COPPERWELD GROUND ROD. 12 PROVIDE 2 #12 AND 1 #12 GND. IN 1/2" CONDUIT TO GRINDER PUMP. SEE DRAWING E2.1 FOR ADDITIONAL INFORMATION. - 11 ALL REPORTS, PLANS SPECIFICATIONS AND COMPUTER FILES RELATING TO THIS PROJECT ARE THE PROPERTY OF CRABTREE, ROHRBAUGH & ASSOCIATES. CRABTREE ROHRBAUGH & ASSOCIATES RETAINS ALL COMMON LAW, STATUTE AND OTHER RESERVED RIGHTS INCLUDING THE COPYRIGHT THERETO. REPRODUCTION OF THE MATERIAL HEREIN OR SUBSTANTIAL USE WITHOUT WRITTEN PERMISSION OF CRABTREE, ROHRBAUGH & ASSOCIATES VIOLATES THE COPYRIGHT LAWS OF THE UNITED STATES AND WILL BE SUBJECT TO LEGAL PROSECUTION. ©CRABTREE, ROHRBAUGH & ASSOCIATES, INC 2018 U) E O V W i V � L r6 V Q 3 z ■ DC W LU a o kD z � z Q > CL O oC LU � Q J G > � G W W � a0 oo� G J LU J Q = m U W a m cc = a Ln O LA Occ DC O J � J = a W a WZ0 Z op N V N O m N Z 00 a LLJ cc r-11 W LEGEND, NOTES, SCHEDULES, RISER, FLOOR PLAN - ELECTRICAL - LIGHTING & POWER PLOT SCALE: As indicated FILENAME: J L,6J O c/) OD = O U 0 J J OD W Q J W � J Z Q N � m 0 � � U w 0 J NO mQ J Q THOMPSON Consulting Engineers 22 ENTERPRISE PARKWAY HAMPTON, VA 23666 TELEPHONE: (757) 599-4415 PAX: (757) 599-4113 PROJECT NUMBER:19052 PROJECT E141 DATE: 11/12/19 0 1 s12-1 KENZIE CAMBAR - Lic. No.049752 11 /12/2019 1m I II I' CONC. WALL TOP ELEV=68726' — — --z— pp 1 \ \ \ Q i II lNIN = 6 .86' \ \ 10" HDPE \ I \ n IN I� OUT�572. I I 10' HDPE 1 l lNV. OU 6K0.30'/ N CMR /15 C1 MP -N 6 SIGNS / WOOD PANEL W/MOUNTED ELECTRIC BOXES I / / T,RA,NSF RMER I I I II / / SD RATE INLET I \ \ \ INV OUT = 661.91' 18" \ \ \ \ EXl I I \ \ \ FRAMEED I \ 1 \ \ \ W /OFTLL I I I I 00� F1 OUSE BALLFIELD G a COGS AREA OF DETAIL -2 OVERALL SITE PLAN - ELECTRICAL SCALE: 1" = 30'-0" IN 1❑ NEW 30KVA TE3AAICClIE3hA 1❑ EXISTING PANEL "A" EXISTING DUGOUT EXISTING �\ FRAME SHED NEW 100A-3P, NEMA 3R 1❑ DISCONNECT SWITCH APPROXIMATE LOCATION OF NEW ELECTRICAL PANEL "FH" \ 1 I GRINDER PUMPIQ[3] I I I I NEW SOFTBALL FIELDHOUSE + \ ENLARGED SITE PLAN - SOFTBALL FIELDHOUSE - ELECTRICAL SCALE: 1 /8" = 1'-0" CONSTRUCTION NOTES: (THIS DRAWING ONLY) SEE ELECTRICAL POWER RISER DIAGRAM ON DRAWING E-1 FOR INFORMATION PERTAINING TO THIS EQUIPMENT. PROVIDE 4 #3 AND 1 #8 GROUND IN 1-1/4" CONDUIT BETWEEN NEW 100A-3P DISCONNECT SWITCH AND NEW PANEL "FH". INSTALL CONDUIT 24" BELOW GRADE. 3❑ SEE PLUMBING DRAWING P2.1 FOR EXACT LOCATION AND ADDITIONAL INFORMATION. \f U ALL REPORTS, PLANS SPECIFICATIONS AND COMPUTER FILES RELATING TO THIS PROJECT ARE THE PROPERTY OF CRABTREE, ROHRBAUGH & ASSOCIATES. CRABTREE ROHRBAUGH & ASSOCIATES RETAINS ALL COMMON LAW, STATUTE AND OTHER RESERVED RIGHTS INCLUDING THE COPYRIGHT THERETO. REPRODUCTION OF THE MATERIAL HEREIN OR SUBSTANTIAL USE WITHOUT WRITTEN PERMISSION OF CRABTREE, ROHRBAUGH & ASSOCIATES VIOLATES THE COPYRIGHT LAWS OF THE UNITED STATES AND WILL BE SUBJECT TO LEGAL PROSECUTION. © CRABTREE, ROHRBAUGH & ASSOCIATES, INC 2018 REVISIONS 01 MM-DD-YR NAME DESCRIPTION OF CHANGES Site Plans - Electrical PLOT SCALE: As indicated FILENAME: DATE: 11/12/19 J W OV) OD =O U � J J pp W Q � J J W Z Q N O � � oc U w 0 J Of m J a THOMPSON Consulting Engineers 2 ENTERPRISE PARKWAY HAMPTON, VA 23666 LELEPHONE: (757) 599-4415 FAX: (757) 599-4113 PROJECT NUMBER:19052 PROJECT E2* I