HomeMy WebLinkAboutARB202000006 Plan - Submittal (First) 2020-01-28BROWNSVILLE ES, 810 CROZET m ROCKFISH GAP TURNPIKE BROWNSVILLE ES HENLEY MS 63 5 HENLEY MS & JOUETT MS ALBEMARLE COUNTY PUBLIC SCHOOLS OWENSVILLE JOUETT MIDDLE SCHOOL 6'76 MA 29 LAMBS LN HYDRAULIC RD 5 ALBEMARLE COUNTY, VIRGINIA PLAN 16 NORTH [it] W CHARLOTTESVILLE 20 5 JANUARY XX, 2020 IF B# XXXX-XXXXX-XX MJT# 19105 Publi* 0 ounty c Schools DRAWING INDEX (BROWNSVILLE ES) SHEET NO. DRAWING TITLES T0.1 TITLE SHEET A1.1 DEMOLITION AND NEW WORK PLANS AND DETAILS -ARCHITECTURAL A1.2 ROOF PLAN AND DETAILS M0.1 GENERAL NOTES, LEGEND, ABBREVIATIONS AND SCHEDULES M0.2 MECHANICAL SCHEDULES M0.3 MECHANICAL SCHEDULES M1.1 BROWNSVILLE ES PARTIAL DEMOLITION AND NEW WORK PLAN -MECHANICAL M2.1 MECHANICAL DETAILS DRAWING INDEX (HENLEY MS) SHEET NO. DRAWING TITLES T0.1 TITLE SHEET A1.3 DEMOLITION AND NEW WORK PLANS AND DETAILS -ARCHITECTURAL M0.1 GENERAL NOTES, LEGEND, ABBREVIATIONS AND SCHEDULES M0.4 WALK-IN FREEZER AND COOLER DETAILS M1.2 HENLEY MS DEMOLITION AND NEW WORK PLAN -MECHANICAL M2.1 MECHANICAL DETAILS DRAWING INDEX (JOUETT MS) SHEET NO. DRAWING TITLES T0.1 TITLE SHEET A1.4 DEMOLITION AND NEW WORK PLANS AND DETAILS -ARCHITECTURAL M0.1 GENERAL NOTES, LEGEND, ABBREVIATIONS AND SCHEDULES M0.4 WALK-IN FREEZER AND COOLER DETAILS M1.3 JOUETT MS DEMOLITION AND NEW WORK PLAN -MECHANICAL M2.1 MECHANICAL DETAILS VICINITY MAP HENLEY MIDDLE SCHOOL O� PLAN 16 NORTH BROWNSVILLE ELEMENTARY SCHOOL D ROCKFISH GAP TURNPIKE VICINITY MAP HENLEY MIDDLE SCHOOL 5880 ROCKFISH GAP TURNPIKE CROZET, VA 22932 BROWNSVILLE ELEMENTARY SCHOOL 5870 ROCKFISH GAP TURNPIKE CROZET, VA 22932 PLAN NORTH B LS N JACK JOUETT MIDDLE SCHOOL 210 LAMBS LN, CHARLOTTESVILLE, VA 22901 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 w QU) � w O Z °6 W U) In w - J � Z C) W w = L1J � w Uw _j LJ� W U) C/)jz DO O 000LL Z D O U w Q Lu m J Q 1 REVISIONS 1 1 MARK I DESCRIPTION I DATE 1 COMM. NO: 19105 DESIGNED BY: JLR DRAWN BY: TGO CHECKED BY: - © COPYRIGHT THOMPSON CONSULTING ENGINEERS TOml DATE: 01 /15/2020 GENERAL NOTES ABBREVIATIONS 1. CONTRACTOR SHALL VISIT JOB SITE TO DETERMINE EXTENT OF WORK 0 DIAMETER L LENGTH INVOLVED PRIOR TO BIDDING THE PROJECT. AC-x AIR CURTAIN DESIGNATION LAT LEAVING AIR TEMPERATURE 2. THE MECHANICAL SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH APD AIR PRESSURE DROP LBS POUNDS THE INTERNATIONAL ENERGY CONSERVATION CODE 2012 AS ADOPTED BY THE VIRGINIA CODE COMMISSION SECTION 101.2 AND SUBSEQUENT BHP BRAKE HORSEPOWER LF LINEAR FEET AMENDMENTS. CFM CUBIC FEET PER MINUTE KMAU-x KITCHEN MAKE-UP AIR UNIT DESIGNATION 3. COORDINATE LOCATION OF ALL DUCTWORK, SUPPLY AND RETURN DEVICES, THERMOSTATS AND OTHER WALL OR CEILING MOUNTED COP COEFFICIENT OF PERFORMANCE MBH 1000 BRITISH THERMAL UNITS PER HOUR EQUIPMENT WITH LIGHT FIXTURES, SPRINKLER SYSTEMS AND COMP COMPRESSOR MCA MINIMUM CIRCUIT AMPS ACCESSORIES INSTALLED BY OTHER TRADES SO AS TO PRESENT A NEAT AND ATTRACTIVE INSTALLATION THROUGHOUT THE BUILDING. CU CONDENSING UNIT (EXISTING) MOCP MAXIMUM OVER CURRENT PROTECTION 4. COORDINATE ALL AIR SUPPLY DEVICES AND EQUIPMENT WITH CU-x CONDENSING UNIT DESIGNATION MIN MINIMUM ARCHITECTURAL REFLECTED CEILING PLANS. D CONDENSATE DRAIN NC NOISE CRITERIA 5. COORDINATE ALL AIR INTAKES AND RELIEF OUTLETS, SIZE AND LOCATION, WITH ARCHITECTURAL DRAWINGS. DB DRY BULB NO NUMBER DN DOWN NTS NOT TO SCALE 6. ALL DIFFUSERS, GRILLES AND REGISTERS SHALL BE SIZED TO HAVE A MINIMUM FREE AREA OF 70% AND MEET PERFORMANCE CRITERIA DX DIRECT EXPANSION OA OUTSIDE AIR SCHEDULED. EA EACH AP PRESSURE DIFFERENTIAL 7. ARRANGE DUCTWORK PARTICULARLY ABOVE CEILING AS REQUIRED TO CLEAR STRUCTURE, CONDUIT, LIGHTS, ETC., ALLOWING SPACE FOR EAT ENTERING AIR TEMPERATURE PH PHASE HANGERS, INSULATION, ETC. EER ENERGY EFFICIENCY RATIO POS POSITION 8. CONTRACTOR SHALL INSTALL ALL WALL MOUNTED SENSORS AT 5-0" FROM FINISHED FLOOR TO CENTERLINE OF SENSOR. ESP EXTERNAL STATIC PRESSURE QTY QUANTITY EF EXHAUST FAN (EXISTING) RD ROOF DRAIN 9. ALL ROUND BRANCH DUCTS TO DIFFUSERS SHALL MATCH NECK SIZES SHOWN ON SCHEDULE, UNLESS OTHERWISE NOTED. EF-x EXHAUST FAN DESIGNATION RH ROOF HOOD (EXISTING) 10. DUCT SIZES SHOWN ARE INSIDE FREE AREA DIMENSIONS. OF DEGREES FAHRENHEIT RPM REVOLUTIONS PER MINUTE 11. PIPING ARRANGEMENTS ARE DIAGRAMMATIC. FD FLOOR DRAIN SEER SEASONAL ENERGY EFFICIENCY RATIO 12. DUCT DIMENSIONS MAY BE MODIFIED AS APPROVED BY ENGINEER. FLA FULL LOAD AMPS SENS SENSIBLE FT FEET SF SQUARE FEET GENERAL DEMOLITION NOTES H HEIGHT SP STATIC PRESSURE 1. WHERE EQUIPMENT IS INDICATED TO BE REMOVED, IT SHALL MEAN HP HORSEPOWER TYP TYPICAL COMPLETE REMOVAL OF EQUIPMENT, INCLUDING CURBS, SUPPORTS, GUYS, ANCHORS, BRACKETS, CONTROLS AND INCIDENTAL ITEMS HZ HERTZ V VOLTS CONNECTED OR FASTENED TO EQUIPMENT. OWNER MAINTAINS THE OWNERSHIP OF ALL ITEMS TAGGED OR IDENTIFIED. IN INCH/INCHES VFD VARIABLE FREQUENCY DRIVE 2. WHERE PIPING IS INDICATED TO BE REMOVED, IT SHALL MEAN COMPLETE IU-x INDOOR UNIT DESIGNATION (EVAPORATOR) WB WET BULB REMOVAL OF PIPING, INCLUDING VALVES, FITTINGS INSULATION, KEF-x KITCHEN HOOD EXHAUST FAN DESIGNATION WC WATER COLUMN SUPPORTS, HANGERS, BRACKETS, CONTROLS AND INCIDENTAL ITEMS CONNECTED OR FASTENED TO THE PIPING. PIPING IS DIAGRAMMATIC AND KH-x KITCHEN HOOD DESIGNATION WG WATER GAUGE INDICATES THE GENERAL EXTENT OF WORK. NO ATTEMPT IS MADE TO SHOW EVERY ELL, TEE, OFFSET, FITTING AND VALVE. REMOVE PIPING AS KW KILOWATT UH UNIT HEATER (EXISTING) INDICATED AND SPECIFIED. 3. WHERE DUCTWORK IS INDICATED TO BE REMOVED, IT SHALL MEAN COMPLETE REMOVAL OF DUCTWORK, INCLUDING FITTINGS, INSULATION, SUPPORTS, BRACKETS, CONTROLS AND INCIDENTAL ITEMS CONNECTED OR FASTENED TO THE DUCTWORK. DUCTWORK IS DIAGRAMMATIC AND INDICATES THE GENERAL EXTENT OF WORK. NO ATTEMPT IS MADE TO SHOW EVERY ELL, TEE, OFFSET AND FITTING. REMOVE DUCTWORK AS INDICATED AND SPECIFIED. 4. REFER TO REFLECTED CEILING PLANS FOR DEMOLITION AND NEW WORK RELATED TO CEILINGS. AIR CURTAIN SCHEDULE (BROWNVILLE ES) UNIT CFM HP V PH MCA MOCP UNIT T SELECTION BASED REMARKS NO. WEIG ON "BERNER" AC-1 1,188 1 /5 120 1 3.4 15 45 CLC08-1042A 1O O2 REMARKS: 0 PROVIDE WITH WHITE POWDER COATED EXTERIOR. O2 PROVIDE WITH DOOR SWITCH AND 24 VOLT LINE VOLTAGE CONTROL. O PROVIDE WITH TOGGLE DISCONNECT SWITCH. WALK-IN COOLER SPLIT SYSTEM REFRIGERATION UNIT SCHEDULE (JOUETT & HENLEY MS) INDOOR UNIT OUTDOOR UNIT REFRIGERANT TYPE UNIT WEIGHT REMARKS UNIT SELECTION BASED ELECTRICAL DATA COOLING CAPACITY UNIT SELECTION BASED ELECTRICAL DATA MCA MOCP V PH TOTAL (MBH) MCA MOCP V PH NO. ON "KEEPRITE" NO. ON "KEEPRITE" (LBS.) IU-1 KLP209MA-S1 B-T 2.3 15 120 1 8.1 CU-1 KEZA007H8-HS2C 8.0 15 208 1 R-404A 201 1002 O REMARKS: O UNITS SHALL SERVE 40OF COOLER WALK-IN BOX AND SHALL BE PROVIDED O WALK-IN BOX WALL PANEL SELECTION BASED ON BY WALK-IN BOX MANUFACTURER. THERMALRITE. REFER TO DRAWING M0.4 FOR DIMENSION INFORMATION. O2 UNIT COOLING COIL CAPACITY IS GROSS CAPACITY. BASED ON 950F DB/780F WB AMBIENT CONDITIONS. WALK-IN FREEZER SPLIT SYSTEM REFRIGERATION UNIT SCHEDULE (JOUETT & HENLEY MS) INDOOR UNIT OUTDOOR UNIT REFRIGERANT TYPE UNIT WEIGHT REMARKS UNIT SELECTION BASED ON ELECTRICAL DATA COOLING CAPACITY UNIT SELECTION BASED ON ELECTRICAL DATA MCA V PH TOTAL (MBH) MCA MOCP V PH NO. "INTERNATIONAL COLD STORAGE" NO. "INTERNATIONAL COLD STORAGE" (LBS.) IU-2 LCE6160BEQRC6B 1.6 120 1 12.4 CU-2 MOZ035L621CSFLT 27 45 208 1 R-404A 315 OOO 4005 ©0® REMARKS: O UNITS SHALL SERVE 0° FREEZER WALK-IN BOX AND SHALL BE OUNIT SHALL BE MOUNTED ON TOP OF FREEZER WALK-IN BOX. PROVIDED BY WALK-IN BOX MANUFACTURER. O PROVIDE WITH ELECTRIC DEFROST OPTION. O UNIT COOLING COIL CAPACITY IS GROSS CAPACITY. BASED ON 950F DB/780F WB AMBIENT CONDITIONS. O COOLING SYSTEM CAPACITY SIZED TO MAINTAIN -10OF AT AMBIENT CONDITIONS OF 100°F. O PROVIDE WITH PRE -MANUFACTURED THERMALLY INSULATED CONDENSATE DRAIN LINE. ® WALK-IN BOX WALL PANEL SELECTION BASED ON INTERNATIONAL COLD O PROVIDE WITH FACTORY PAINTED COLONIAL RED PAINT OPTION STORAGE REFER TO DRAWING M0.4 FOR DIMENSION INFORMATION. FOR WALK-IN BOX AND ACCESSORIES. LEGEND ---I VOLUME DAMPER G EMERGENCY PULL STATION Q xx THERMOSTAT OR TEMPERATURE SENSOR, CONTROLLING UNIT AS INDICATED SUPPLY AIR DEVICE WITH FLEXIBLE DUCT DUCTWORK DUCT ELBOW WITH TURNING VANE DUCT TRANSITION DUCT SECTION - RETURN/EXHAUST DUCT SECTION - SUPPLY DUCTWORK TURNING DOWN 90° DUCT ELBOW - TURNED UP FLEXIBLE DUCT (0; ROOF MOUNTED EXHAUST FAN SUPPLY AIR DEVICE e SUPPLY DUCT UP THROUGH ROOF 0 EXHAUST DUCT UP THROUGH ROOF DIRECTION OF AIRFLOW GCFM DIFFUSER, REGISTER, AND GRILLE, CFM AS INDICATED POINT OF CONNECTION FOR NEW WORK REMOVE EXISTING TO THIS POINT 10 DEMOLITION NOTE it NEW WORK NOTE 65% OWNER (9"/9") EXISTING SIZES AS INDICATED REVIEW EXISTING TO REMAIN NOT FOR NEW WORK CONSTRUCTION r EXISTING TO BE REMOVED 01-15-20 L. _ _ _ J DIRECTION OF FLOW IN PIPE C� PIPE DOWN EXISTING PIPING TO REMAIN N D DRAIN PIPING z �_ O X DIRECTION OF PITCH FOR PIPING OR DUCTWORK �^ w �J x �--HWR----q HOT WATER RETURN PIPING �---HWS----i HOT WATER SUPPLY PIPING EXISTING GATE VALVE y EXISTING CHECK VALVELn .� A PHOTOGRAPH: LETTER "A" w SEE SHEET MXXX Mxx W 0 �� zW U Wa N E- HEAT TRACE SCHEDULE (JOUETT & HENLEY MS) EQUIPMENT SERVED NO. OF STRIPS WATTS/LF V PH APPROXIMATE LENGTH OF PIPING SERVED APPROXIMATE WATTAGE METHOD OF CONTROL REMARKS IU-1 FREEZER CONDENSATE PIPING 1 20 120 1 12 FT 240 FIELD CONTROLLER IU-1 FREEZER CONDENSATE PIPING 1 20 120 1 12 FT 240 FIELD CONTROLLER 0 0 REMARKS: O REFER TO SPECIFICATION 230500 FOR ADDITIONAL O JOUETT MIDDLE SCHOOL ONLY. REQUIREMENTS. O2 FIELD VERIFY TOTAL LENGTH OF INSTALLED HEAT 4O HENLEY MIDDLE SCHOOL ONLY. TRACE FOLLOWING INSTALLATION. GRILLE, REGISTER & DIFFUSER SCHEDULE (BROWNSVILLE ES) MARK NECK DESCRIPTION MATERIAL FINISH VOLUME SHAPE MAXIMUM MAXIMUM SELECTION BASED ON REMARKS SIZE DAMPER oP NC "PRICE" O 6"o LOUVERED FACE ADJUSTABLE CEILING DIFFUSER STEEL WHITE NO SQUARE 0.1" 25 SCDA OO O 8"o LOUVERED FACE ADJUSTABLE DIFFUSER STEEL WHITE NO SQUARE 0.1" 25 SCDA (DO O 22„ x 2211 CEILING RETURN OR EXHAUST GRILLE 450 DEFLECTION, 3/4" SPACING STEEL WHITE NO SQUARE 0.1" 25 530 O REMARKS: O REFER TO ARCHITECT'S REFLECTED CEILING PLAN FOR CEILING TYPES. FOR ACOUSTIC CEILING, PROVIDE WITH 24" x 24" PANEL SUITABLE FOR MOUNTING IN LAY -IN GRID. FOR DRYWALL CEILING, PROVIDE WITH SMALL FACE AND SURFACE MOUNT FRAME. O PROVIDE 4-CONE, 24" x 24" FACE MOUNTED IN 2' x 2' METAL PANEL. Q z 0 z D O U w Q W m Q Cn Lu 0 W U U) Q z O Q w ry m m Q 0 z Lu Lu W O J z LLJ (D REVISIONS MARK DESCRIPTION DATE COMM. NO: 19105 DESIGNED BY: JLR DRAWN BY: TGO CHECKED BY: - © COPYRIGHT THOMPSON CONSULTING ENGINEERS DATE: 01 /15/2020 KITCHEN HOOD SCHEDULE (BROWNSVILLE ES) HOOD DIMENSIONS HOOD EXHAUST TOTAL LIGHTING DETAILS GREASE FILTRATION UTILITY CABINET SELECTION HOOD UNIT NO. OD MATERIAL O TEMP WEIGHT BASED ON "CAPTIVEAIRE" REMARKS LENGTH WIDTH HEIGHT TOTAL COLLAR(S) FIXTURE TYPE QTY TYPE / MODEL QTY SIZE (IN.) LOCATION SIZE FIRE SYSTEM ELECTRICAL WIDTH LENGTH CFM S.P. L H TYPE SIZE RATING CFM (LBS) MATERIAL MODEL 1 KH-1 10'-511 4'-611 2'-011 304 SS WHERE 600 o2,500 (F) 10" 12" 1,250 0.8 793 L55 SERIES E26 3 CAPTRATE SOLO STAINLESS STEEL 7 16 16 LEFT 12"x54"x24" ANSUL R102 3.0 DCV-2111 5424ND-2-PSP C)Qo@oQ(D EXPOSED 10" 1211 1,250 0.8 KH-2 10'-511 4'-611 2'-011 304 SS WHERE 600 (OF)2,500 10" 12" 1,250 0.8 725 L55 SERIES E26 3STAINLESS CAPTRATE SOLO STEEL 7 16 16 RIGHT - ANSUL R102 3.0 - 5424ND-2-PSP &D(D(D(D&D2 EXPOSED 1011 1211 1,250 0.8 REMARKS: O BACK INTEGRAL AIR SPACE 3" WIDE. OPROVID FACTORY MOUNTED EXHAUST COLLARS. 0 PROVIDE WITH HEAT SENSORS AND INTERLOCK WITH EXHAUST FAN VFD. 2O PROVIDE WITH 18" HIGH CEILING ENCLOSURES. 4O PROVIDE WITH FIELD MOUNTED AND © PROVIDE WITH MANUFACTURER'S BACKSPLASH. 70 PROVIDE WITH REMOTE MANUAL PULL STATION. FRONT, LEFT AND RIGHT FIELD INSTALLED. LOCATION ADJUSTABLE EXHAUST COLLAR. KITCHEN HOOD SUPPLY PLENUM SCHEDULE (BROWNSVILLE ES) HOOD SIZE (IN.) TOTAL COLLARS NO. UNIT NO. POS. MODEL INSULATED DAMPER(S) CFM L W H TYPE MOUNTING QTY W L CFM S.P. 1 KH-1 FRONT PSP 137 16 6 NO NO 2,000 MAKE FACTORY 4 12" 20" 498 0.14 UP AIR 1 KH-2 FRONT I PSP 1 137 1181 6 1 NO I NO 2,000 MAKE FACTORY 4 12' 20" 498 0.14 UP AIR KITCHEN HOOD EXHAUST FAN SCHEDULE (BROWNSVILLE ES) UNIT INFORMATION FAN INFORMATION ELECTRICAL UNIT SELECTION UNIT NO. VOLUME (CFM) ESP (IN.) FAN RPM HP SONES V PH WEIGHT (LBS) BASED ON "CAPTIVEAIRE" REMARKS KEF-1 5,250 1.5 1,135 2 17.6 208 3 207 DU200HFA O O 0 KEF-2 5,250 1.5 1,135 2 17.6 208 3 207 DU200HFA O O O REMARKS: O PROVIDE WITH MANUFACTURER'S VENTED ROOF CURB. 2O PROVIDE WITH VARIABLE FREQUENCY DRIVE. 30 PROVIDE WITH HINGED CURB BASE. 1 V-5.00" OVERALL LENGTH 1./10' 5.00 REMO PULL: REMO\ STEEL ✓I \nVI\L I /1VV LI VI✓L I V 1 ILI I I VnU 11 VL I PLENUM PROTECTION A lrl-7-7l r /T\/r-NI /"CAI \ 341/2" �1711 KITCHEN HOOD FIRE SUPPRESSION SYSTEM ANSUL R-102 ISOMETRIC VIEW (BROWNSVILLE ES', 7811 2211 0 991 -T 911 � 911 � 911 12" 12" 12" 12' ®0 0 0" 2011 2011 2011 1 o LED LIGHTS w z m U J 121I 121I rq�///'/ --T 1111111117 --T r/// x 10" " --1011 0 91I � FZ/// 9" � o o �V//77 g" o 10" 1011 z1211 1211 m Q U J_ LED LIGHTS H Utility Cabin �—.-R�,20" 2011 2011 2011 a o-F P��7 T T ®o 1211 1211 91Field Cut 1211 g� 1211 9" � 911 0 i I I®0 1711 1211 mm 10' 5"NOM./10' 5.00"C 1 V-5.00" OVERALL LENGTH 5411 5411 NOT TO SCALE ACT CEILING L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (1-55 FIXTURE) NRAPPER 18.00" HIGH G ENCLOSURE HING PLATES Y RISER WITH /lE DAMPER 23.5% OPEN STAINLESS STEEL PERFORATED PANEL ACT CEILING 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 w QU) CD � � w O Z °6 W U) � w �z cy w W= W � w Uw 0� > w U) U)Z 3: 0 O 00m LL Z O U w CQ NGN L.f MW W Q W D 0 Lu U) J U_ Z 2 U 2 REVISIONS MARK I DESCRIPTION I DATE COMM. NO: DESIGNED BY DRAWN BY: CHECKED BY: 19105 JLR TGO PLAN VIEW HOOD (BROWNSVILLE ES NOT TO SCALE © COPYRIGHT THOMPSON CONSULTING ENGINEERS KITCHEN HOOD SIDE VIEW (BROWNSVILLE ES NOT TO SCALE (TYPICAL FOR KH-1 & KH-2) MOm2 DATE: 01 /15/2020 KITCHEN HOOD MAKE-UP AIR UNIT SCHEDULE (BROWNSVILLE) UNIT BLOWER HOUSING CFM ESP RPM MOTOR SONES KW OUTPUT EAT LAT V PH FLA WEIGHT SELECTION BASED ON REMARKS NO. MODEL MODEL (IN) HP (MBH) (OF) (OF) (LBS) "CAPTIVEAIRE" KMAU-1 24MF-3-MOD A3-E.642 4,000 0.4 917 3 7.2 64 218.4 15.0 65.3 208 3 10.2 945 A3-E.642-24D 1002 O3 4005 O6 O7 O8 REMARKS: 10 PROVIDE WITH AC INTERLOCK RELAY - 24VAC COIL. G UNIT WEIGHT DOES NOT INCLUDE ROOF CURB. 7O UNIT HEAT DISCHARGE TEMPERATURE SET 20 PROVIDE WITH MOTORIZED BACKDRAFT 50 PROVIDE WITH MANUFACTURER'S ROOF CURB. POINT SHALL BE 70 F (ADJUSTABLE). DAMPER. 80 PROVIDE WITH DEMAND CONTROLLED VENTILATION. PROVIDE WITH VARIABLE FREQUENCY DRIVE. 30 60 PROVIDE WITH 6 STAGE ELECTRIC HEAT. BREAKER PANEL TO PRIMARY CONTROL PANEL RESPONSIBILITY: ELECTRICIAN BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER PANEL PRIMARY CONTROL PANEL BREAKER 1 PH NEUTRAL 120 V--------------------------------------GROUND -------------------------------------- 15 A CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER3PH 208 V MCA: 19.8 A MOCP: 30 A BREAKER3PH 208 V MCA: 12.8 A MOCP: 30 A Load Wiring SM-1 WIRE TO VFD QUICK CONNECTOR LOAD WIRING SM-2 WIRE TO VFD QUICK (-.nNINIFrTnR EXH-1 SM-1 WIRE TO VFD QUICK CONNECTOR SUP-2 S M-2 WIRE TO VFD QUICK CONNECTOR CONTROL PANEL TO FANS RESPONSIBILITY: ELECTRICIAN IF VFD MOUNTED IN 2ND PANEL, WIRE SF SIGNAL FROM PANEL WITH ECPM03. MAKE UP AIR ON PCB DAMPER 1ILlAC PROVING IL1 BC INTERLOCK IIAI►1q IIAI0Iq FAN: 01 EXH-1 FLA:15.8 HP: 5.000 VOLT:208 V ----- �n�� ��------ III WIRE TO MUST HAVE ITS OWN CONDUIT DISCONNECT DO NOT SHARE CONDUIT! FAN: 02 SUP-2 ____LOAD LEG 1 BLACK HP: 3. 0 0 HP: 3000 BLACK VOLT:208 V MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! REMOVEJUMPER MUA ZONE 1 LOW VOLTAGE CONNECTION FOR TERMINAL NAMES DAMPER INTERLOCK. WIRE DO NOT APPLY MULTIPLE SUPPLY ON THE SAME IF MUA BY OTHERS ZONE IN SERIES. SHOULD HAVE CONTINUITY WHEN DAMPER IS PROVEN OPEN. NOT REQUIRED FOR ALL UNITS. SEE MAKE-UP AIR SCHEMATIC. :ONTROL PANEL TO FIRE SYSTEM MICROSWITCH IF MORE THAN ONE FIRE SYSTEM, WIRE IN SERIES AS SHOWN NTROL PANEL J4 TO SWITCHES TO HOOD LIGHTS 1400 W MAX TO KITCHEN TEMP SENSOR TO DUCT SENSOR TO DUCT SENSOR SIGNAL FOR EXTERNAL SHUNT TRIP CONTROL PANEL TO ACCESSORY ITEMS RESPONSIBILITY: ELECTRICIAN )L PANEL COMPONENT ROSWITCH 1 4-NO C �2 N C WIRE Cl TO COMMON (1). WIRE AR1 TO NORMALLY CLOSED (2). Cl TO AR1 SHOULD HAVE CONTINUITY WHEN ARMED. ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION MS-1 4:NO MS-2 —4:NO HOOD LIGHTS 1 •-----------------------------BLACK- ----- -----------------------------WHITE--------� I ----------------------------- GREEN_ _ ' -----------J WIRE TO J-BOX ON TOP OF HOOD ROOM TEMP SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR ON THE CEILING GRID, SEE MANUAL. FACTORY WIRED TEMPERATURE HOOD 1 SENSOR. MOUNTED IN EXHAUST DUCT RISER 1 WIRE TO CONTROL BOARD. HOOD 2 SENSOR MOUNTED IN EXHAUST DUCT RISER 1 SHUNT COIL HOT TO SHUNT COIL n„ ST TERMINAL IS ENERGIZED IN FIRE CONDITION. KITCHEN HOOD CONTROL PANEL (BROWNSVILLE NOT TO SCALE 14 2011 Er V11 IVILIV 1 ,, CONTROL PANE C2 _COMMON SPARE FIRE _ NORMALLY OPEN_ SPARE CONTACTS WILL MAKE C2 TO SYSTEM DRY AR2 WHEN SYSTEM IS ARMED. THEY CONTACT ARE USED TO DISABLE EQUIPMENT OR PROVIDE SIGNALS. (NOT FOR BUILDING FIRE ALARM WHICH MUST BE WIRED DIRECTLY TO THE ANSUL ALARM INITIATING SWITCH LOCATED IN ANSUL AUTOMAN) CONTROL PANE -------------------------------------- TO101 -------------------------------------- EXTERNAL SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND SWITCH LIGHTS 3511 BMS SWITCH SUPPLY AIR CONNECTION 20" 14 3/4" MAKEUP AIR UNIT KMAU-1 DETAIL (BROWNSVILLE NOT TO SCALE El 3� IJVV I VVVIXFX UL I VVILLIV EXHAUST FAN AND KITCHEN HOOD /211 31-1/2" VENTED CURB HINGED )GAUGE FEEL DNSTRUCTION 1 L/-IIVVL ROOF OPENING 31" DIMENSIONS 31" KITCHEN EXHAUST FAN KEF-1 DETAILS (BROWNSVILLE NOT TO SCALE 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 w Q� CD � � w O Z °6 W � n w — J � Z C) W L1J = W U) w Uw J w U) � Z 00 0m 0 LL D 0 U W ry Q 75 ry W m J Q UJI J Z) 0 UJI U) J U z Q U Lu REVISIONS MARK DESCRIPTION DATE COMM. NO: 19105 DESIGNED BY: JLR DRAWN BY: TGO CHECKED BY: - © COPYRIGHT THOMPSON CONSULTING ENGINEERS M003 DATE: 01 /15/2020 65% OWNER REVIEW COOLER WALK-IN BOX FLOOR DETAIL NOT TO SCALE FREEZER WALK-IN BOX FLOOR DETAIL NOT TO SCALE CLOSER LATCH \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ 30" HIGH DIAMOND TREAD \/\/ \ \ \\\\\\\\\\\\\\\ \\\\\\\\\\\\\\\ \ \ \ \\\\\\\\\\\\\\\ \ \ \\\\\\\\\\\\\\\ \ M 0 A 11 FLOOR RECESSED IN EXISTING OPENING. - COOLER WALK-IN BOX ELEVATION DETAIL NOT TO SCALE N N O r WALK-IN COOLER AND FREEZER COMPONENTS ARE ONLY APPLICABLE TO HENLEY MS AND JOUETT MS. A 11 N CO 00 3 5/8 FREEZER WALK-IN BOX ELEVATION DETAIL NOT TO SCALE TOP AND 1/4"x1-1/4" HH WALK-IN SIDES OF TEK SCREW EXTERIOR COVER TO (TYP 10) BE PLOSEE W/FLANGE ANCHORS PROVIDED & INSTALLED BY OTHERS TIE-D( COVE m m m m 0 0 CONCRETE TIE -DOWN JSLAB MACTAC ADHESIVE TA Mr L-12 TIE -DOWN **AS AN OPTION OR CODE REQUIREMENT** FREEZER MOUNTING DETAIL NOT TO SCALE CONTINUOUS BEAD OF SEALANT (BY OTHERS) COUNTERFLASHING (BY OTHERS) 4" x 4" FLASHING (INSTALLED BY OTHERS) SEE NOTE 3 2 x 4 BLOCKING CUT TO FIT (OPTION FROM ICS) SEE NOTE 3 -TEK SCREW WITH WASHER - SEE NOTE 1 1-1/2" x 1-1/2" x 1-1/2" FLASHING (BY ICS) SEE NOTE 3 /-- 1-1/2" STANDING TEE ROOF (INSTALLED BY ICS) CONTINUOUS BEAD OF SILICONE SEALANT TOP AND BOTTOM (BY OTHERS) ICS WALK-IN ROOF BUILDING WALL NOTES: 1. TEK SCREW WITH BONDED WASHER AT 12" O.C. (BY OTHERS) TEK SCREW SHALL NOT PENETRATE STANDING TEE ROOF, FLANGES OR ROOF CAP. 2. BUILDING HEIGHT VARIES WITH BUILDING WIDTH. SEE DRAWING 3. FLASHING KIT AVAILABLE FROM ICS INCLUDES: A) 4" x 4" FLASHING PIECE x LENGTH OF WALK—IN. (SUPPLIED ONLY) B) 2" x 4" BLOCKING FACTORY INSTALLED. C) 1-1/2" x 1-1/2"x 1-1/2" FLASHING FACTORY INSTALLED. KIT DOES NOT INCLUDE COUNTERFLASHING, SEALANT OR FASTENERS. FREEZER ROOF FLASHING DETAIL NOT TO SCALE 1/2" 1/2" EXPANSION JOINT WITH BACKER ROD AND SEALANT L CORNER TRIM FURNISHED BY GENERAL CONTRACTOR (AVAILABLE AS AN OPTION FROM ICS). SET IN CONTINUOUS BEAD OF SEALANT, SECURE TO WALL AND TO UNIT AT WALL. FREEZER CORNER TRIM DETAIL NOT TO SCALE BUILDING WALL NOT FOR CONSTRUCTION 01-15-20 w Q� �w 0 z °6 w U' 2 >m nw — J � Z C) W L1J = W � w Uw �/ J LJ� W U) �z 0 O 0m o LL Q Z 0 Z D O U W ry Q 75 ry W m Q J_ Q W 0 W J O O LLI 0 Q N W Lu Y Q E REVISIONS MARK DESCRIPTION DATE COMM. NO: DESIGNED BY DRAWN BY: CHECKED BY: 19105 JLR TGO © COPYRIGHT THOMPSON CONSULTING ENGINEERS M004 DATE: 01 /15/2020 EFL I I LOCKER OFFICE GARAGE � J� �2 KEF D2 KEF I KH li 7:7 I 6Dl EXIST SOFFIT KITCHEN SERVING LINE PARTIAL FLOOR PLAN -MECHANICAL -DEMOLITION (BROWNSVILLE ES SCALE: 1/4" = V-0" EF - I I LOCKER OFFICE GARAGE /- EXIST SOFFIT KITCHEN I I SERVING LINE KEF-1 vr_:c_7 KH-1 PARTIAL ROOF PLAN -MECHANICAL -DEMOLITION (BROWNSVILLE ES SCALE: 1/4" = V-0" HIGH ROOF HIGH ROOF DEMOLITION NOTES O NO. DESCRIPTION D1 REMOVE KITCHEN HOOD, DUCTWORK, CONTROLS AND ACCESSORIES COMPLETE. D2 REMOVE KITCHEN EXHAUST FAN, DUCTWORK AND CONTROLS COMPLETE. ROOF CURB TO REMAIN. D3 REMOVE DUCTWORK, DIFFUSERS AND SUPPORTS COMPLETE. D4 REMOVE ANSUL FIRE SUPPRESSION SYSTEM, PIPING, CONDUIT AND CONTROLS COMPLETE. D5 REMOVE KITCHEN HOOD EMERGENCY PUSH STATION SWITCH. D6 REMOVE WALL MOUNTED FAN AND REPAIR CEILING. REFER TO ARCHITECTURAL DRAWINGS FOR PATCHING AND PAINTING. NEW WORK NOTES NO. DESCRIPTION 1 PROVIDE MAKEUP AIR UNIT, ROOF CURB, AND CONTROLS COMPLETE. REFER TO STRUCTURAL DRAWINGS FOR STEEL SUPPORT INFORMATION. REFER TO ARCHITECTURAL DRAWINGS FOR ROOF FLASHING INFORMATION. 2 PROVIDE NEW KITCHEN HOOD SYSTEM. PACKAGE SHALL INCLUDE EXHAUST FAN, HOOD, CONTROLLER, NEW ANSUL SYSTEM, AND NEW DUCT SENSOR. REFER TO 230500 SPECIFICATIONS. 3 ROUTE DUCTWORK THRU ROOF CURB AND SEAL WATERTIGHT. REFER TO "DUCT THRU ROOF CURB DETAIL" ON DRAWING M2.1. 4 PROVIDE EXHAUST DUCTWORK CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, SECTION 506. PROVIDE (2) LAYERS OF GREASE DUCT FIREWRAP INSULATION ON EXHAUST DUCT UP TO ROOF. 5 PROVIDE NEW CURB ADAPTER AND MOUNT ON EXISTING EXHAUST FAN CURB. 6 TRANSITION 18"/12" EA DUCT UP TO 28"/28" EXHAUST FAN OPENING. 7 PROVIDE 14"/12" BRANCH DUCT AND ROUTE TO KITCHEN HOOD, TYPICAL OF 3. 8 ROUTE DUCTWORK BETWEEN AND THROUGH JOISTS. 9 PROVIDE KITCHEN HOOD REMOTE PULL SWITCH AND WIRING COMPLETE. PROVIDE SURFACE MOUNTED RACEWAY TO CONCEAL CONTROL WIRING. PAINT RACEWAY TO MATCH EXISTING WALL COLOR. 10 PROVIDE STAINLESS STEEL DUCTWORK AND TRANSITION FROM ABOVE CEILING DOWN TO DISHWASHER CONNECTIONS. 11 14"/14" DUCT UP TO ROOF. 12 PROVIDE 24"/12" SUPPLY DUCT TRANSITIONS. BALANCE SUPPLY TRANSITIONS TO 612 CFM, TYPICAL OF 3. 13 PROVIDE AIR CURTAIN, SUPPORTS AND CONTROLS COMPLETE. MOUNT PER MANUFACTURER'S RECOMMENDATIONS ABOVE EXTERIOR DOOR. 14 PROVIDE STAINLESS STEEL DUCTWORK AND TRANSITION FROM ABOVE CEILING DOWN TO DISHWASHER CONNECTIONS. 15 PROVIDE SINGLE WALL ROOF MOUNTED DUCTWORK WITH 3" EXTERIOR INSULATION AND WEATHER BARRIER. REFER TO "EXTERIOR DUCTWORK INSULATION AND WEATHERPROOFING DETAIL" ON DRAWING M2.1. BETWEEN SOLID WALLS. COAT DUCTWORK WITH WEATHERPROOF COATING PRIOR TO INSULATION. NOTE: EXISTING CONDITIONS ILLUSTRATED HAVE BEEN DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND LIMITED NON-INVASIVE FIELD INVESTIGATION. THE CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO COMMENCEMENT OF WORK, COORDINATE AND MAKE ADJUSTMENTS AS NECESSARY. VERIFY ALL CIRCUITS SAVED DURING DEMOLITION AS TO WIRE SIZE, CIRCUIT BREAKER SIZE AND POINT OF ORIGIN. 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 Q z 0 J Q U_ z 2 W z J Y O W z 0 z Q O F- _I O W 0 J Q F- Q W Lu U) z O ry m REVISIONS MARK DESCRIPTION DATE COMM. NO: DESIGNED BY DRAWN BY: CHECKED BY: 19105 JLR TGO PARTIAL FLOOR PLAN -MECHANICAL -NEW WORK (BROWNSVILLE ES SCALE: 1/4" = V-0" © COPYRIGHT THOMPSON CONSULTING ENGINEERS PARTIAL ROOF PLAN -MECHANICAL -NEW WORK (BROWNSVILLE ES' SCALE: 1/4" = V-0" KEY PLAN NOT TO SCALE BROWNSVILLE ES DATE: 01 /15/2020 DEMOLITION NOTES O NO. DESCRIPTION D1 REMOVE CONDENSING UNIT, REFRIGERANT PIPING, SUPPORT STAND, AND CONTROL WIRING COMPLETE. ADDITIVE BID. D2 REMOVE FREEZER EVAPORATOR UNIT, REFRIGERANT PIPING, CONDENSATE PIPING AND CONTROL WIRING COMPLETE. ADDITIVE BID. D3 REMOVE FREEZER BOX WALL, CEILING PANELS AND DOOR COMPLETE. D4 REMOVE SIDEWALL EXHAUST FAN, GRILLE AND CONTROLS COMPLETE. REFER TO ARCHITECTURAL DRAWINGS FOR WALL PATCHING INFORMATION. D5 STORAGE SHED TO BE RELOCATED BY ALBEMARLE PUBLIC SCHOOLS STAFF PRIOR TO CONSTRUCTION. 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 I I X CU 4 12Ao `_�� EF EXIST � FENCE O X i------- v,0 w STORAGE STORAGE r� I w x CU I r1 I w �I I o I IIL IU II RFD FD I D3 �w FREEZER o DRY FOOD OUTSIDE O z w I I STORAGE STORAGE U N w E F� EXISTING WORK IN THIS AREA NOT SHOWN. Q PARTIAL FLOOR PLAN - MECHANICAL DEMOLITION(HENLEY MS z ) 0 SCALE: 1 /4" = 1'-0" W Q �y U I� n� � Z V ~ 2 W U W 0 Z Z °6 Q W 2 ry � O � W � — J z z 0 W 0 W Q W (n Z W O U W ---- 6 - 9---�Lu LL i ---- i W ------- 1 IU-2 i i W i 3 CU-2 i �i � Z J 11 i 0°F i t CU Z FREEZER i * O 0 = i I EXIST t o U 10 2 6 i 5 3/4" D i FENCE I / W i L J Q STORAGE STORAGE V 7 1" D ROOF W m El IU-1 Q FD NOTE: EXISTING CONDITIONS ILLUSTRATED HAVE BEEN 10 4 DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND LIMITED NON-INVASIVE FIELD cal))f INVESTIGATION. THE CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO COMMENCEMENT OF WORK, COORDINATE AND MAKE ADJUSTMENTS AS NECESSARY. DRY FOOD OUTSIDE VERIFY ALL CIRCUITS SAVED DURING DEMOLITION AS TO 40°F COOLER WIRE SIZE, CIRCUIT BREAKER SIZE AND POINT OF ORIGIN. STORAGE STORAGE REVISIONS ElMARK DESCRIPTION DATE J L CU-1 EXISTING WORK IN THIS AREA NOT SHOWN. AREA OF WORK COMM. NO: 19105 DESIGNED BY: JLR DRAWN BY: TGO CHECKED BY: - r-L PARTIAL FLOOR PLAN - MECHANICAL - NEW WORK (HENLEY MS) PARTIAL ROOF PLAN - MECHANICAL - NEW WORK (HENLEY MS) KEY PLAN (HENLEY MS)M • 2 SCALE: 1 /4" = 1'-0" SCALE: 1 /4" = 1'-0" NOT TO SCALE DATE: 01 /15/2020 NEW WORK NOTES NO. DESCRIPTION 1 PROVIDE FREEZER/COOLER INDOOR EVAPORATOR UNIT, SUPPORTS, PIPING AND CONTROL WIRING COMPLETE. ROUTE REFRIGERANT PIPING UP TO CONDENSING UNIT LOCATED ON ROOF. SEAL FREEZER/COOLER PENETRATIONS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2 PROVIDE WALK-IN BOX AND ACCESSORIES COMPLETE. REFER TO DRAWING M2.1 FOR DETAILS. INSTALL UNIT IN STRICT ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. FLOOR SHALL BE LEVELED PRIOR TO INSTALLATION, REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISHING DETAILS. 3 PROVIDE CONDENSING UNIT, REFRIGERANT PIPING, SUPPORTS, AND CONTROL WIRING COMPLETE. REFER TO ROOFTOP CONDENSING UNIT SUPPORT DETAIL ON DRAWING M2.1. 4 ROUTE FREEZER/COOLER REFRIGERANT PIPING DOWN THROUGH ROOF PITCH POCKET AND SEAL WATERTIGHT. REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS. 5 PROVIDE COPPER CONDENSATE DRAIN PIPING AND SUPPORTS, SIZE AS SHOWN. PROVIDE HEAT TRACE ON ALL CONDENSATE PIPING LOCATED IN FREEZER AT 20 WATTS PER LINEAR FOOT. SEAL FREEZER/COOLER PENETRATIONS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6 CONTRACTOR SHALL VENTILATE WALK-IN FREEZER AND COOLER A MINIMUM OF 4 DAYS PRIOR TO STARTING THE UNIT TO PREVENT VOC OFF BUILDUP. 7 SECURE CONDENSATE PIPING ALONG WALL AND ROUTE TO FLOOR DRAIN. 8 PROVIDE A CONCRETE SPLASH BLOCK. 9 PROVIDE 1" COPPER CONDENSATE DRAIN PIPING AND SUPPORTS. CONNECT TO FREEZER/COOLER PRE -MANUFACTURED CONDENSATE DRAIN. 10 REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR WALL PATCHING INFORMATION. 11 REFER TO STRUCTURAL DRAWINGS FOR CONCRETE SLAB INFORMATION. © COPYRIGHT THOMPSON CONSULTING ENGINEERS 12I EF STORAGE STORAGE 0 — CU I _ FD EF D5 I I I I I I I I I I I I I I I I I I Irk � III I D6 � I IL IU I FD II D3 II �i II FREEZER II II �I I I X CU I EXIST FENCE DRY FOOD STORAGE EXISTING WORK IN THIS AREA NOT SHOWN. PARTIAL FLOOR PLAN -MECHANICAL DEMOLITION (JOUETT MS SCALE: 1/4" = 1'-0" OUTSIDE STORAGE DEMOLITION NOTES O NO. DESCRIPTION D1 REMOVE CONDENSING UNIT, REFRIGERANT PIPING, SUPPORT STAND, AND CONTROL WIRING COMPLETE. ADDITIVE BID. D2 REMOVE FREEZER EVAPORATOR UNIT, REFRIGERANT PIPING, CONDENSATE PIPING AND CONTROL WIRING COMPLETE. ADDITIVE BID. D3 REMOVE FREEZER BOX WALL, CEILING PANELS AND DOOR COMPLETE. D4 REMOVE SIDEWALL EXHAUST FAN, GRILLE AND CONTROLS COMPLETE. REFER TO ARCHITECTURAL DRAWINGS FOR WALL PATCHING INFORMATION. D5 STORAGE SHED TO BE RELOCATED BY ALBEMARLE PUBLIC SCHOOLS STAFF PRIOR TO CONSTRUCTION. NEW WORK NOTES ❑ NO. DESCRIPTION 1 PROVIDE FREEZER/COOLER INDOOR EVAPORATOR UNIT, SUPPORTS, PIPING AND CONTROL WIRING COMPLETE. ROUTE REFRIGERANT PIPING UP TO CONDENSING UNIT LOCATED ON ROOF. SEAL FREEZER/COOLER PENETRATIONS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2 PROVIDE WALK-IN BOX AND ACCESSORIES COMPLETE. REFER TO DRAWING M2.1 FOR DETAILS. INSTALL UNIT IN STRICT ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. FLOOR SHALL BE LEVELED PRIOR TO INSTALLATION, REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISHING DETAILS. 3 PROVIDE CONDENSING UNIT, REFRIGERANT PIPING, SUPPORTS, AND CONTROL WIRING COMPLETE. REFER TO ROOFTOP CONDENSING UNIT SUPPORT DETAIL ON DRAWING M2.1. 4 ROUTE FREEZER/COOLER REFRIGERANT PIPING DOWN THROUGH ROOF PITCH POCKET AND SEAL WATERTIGHT. REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS. 5 PROVIDE COPPER CONDENSATE DRAIN PIPING AND SUPPORTS, SIZE AS SHOWN. PROVIDE HEAT TRACE ON ALL CONDENSATE PIPING LOCATED IN FREEZER AT 20 WATTS PER LINEAR FOOT. SEAL FREEZER/COOLER PENETRATIONS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 6 CONTRACTOR SHALL VENTILATE WALK-IN FREEZER AND COOLER A MINIMUM OF 4 DAYS PRIOR TO STARTING THE UNIT TO PREVENT VOC OFF BUILDUP. 7 SECURE CONDENSATE PIPING ALONG WALL AND ROUTE TO FLOOR DRAIN. 8 PROVIDE A CONCRETE SPLASH BLOCK. 9 PROVIDE 1" COPPER CONDENSATE DRAIN PIPING AND SUPPORTS. CONNECT TO FREEZER/COOLER PRE -MANUFACTURED CONDENSATE DRAIN. 10 REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR WALL PATCHING INFORMATION. 11 REFER TO STRUCTURAL DRAWINGS FOR CONCRETE SLAB INFORMATION. NOTE: EXISTING CONDITIONS ILLUSTRATED HAVE BEEN DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND LIMITED NON-INVASIVE FIELD INVESTIGATION. THE CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO COMMENCEMENT OF WORK, COORDINATE AND MAKE ADJUSTMENTS AS NECESSARY. VERIFY ALL CIRCUITS SAVED DURING DEMOLITION AS TO WIRE SIZE, CIRCUIT BREAKER SIZE AND POINT OF ORIGIN. AREA C WORK U) w D O 06 U) 2 w J Z w U) W 65% OWNER REVIEW NOT FOR CONSTRUCTION w 0 Q CD 0 W W U i w 01-15-20 Z D O U W Q ry W m J Q 1 REVISIONS 1 1 MARK I DESCRIPTION I DATE 1 COMM. NO: 19105 DESIGNED BY: JLR DRAWN BY: TGO CHECKED BY: - Ml 03 PARTIAL FLOOR PLAN -MECHANICAL -NEW WORK (JOUETT MS SCALE: 1/4" = 1'-0" © COPYRIGHT THOMPSON CONSULTING ENGINEERS PARTIAL ROOF PLAN -MECHANICAL -NEW WORK (JOUETT MS SCALE: 1/4" = 1'-0" KEY PLAN (JOUETT MS' NOT TO SCALE DATE: 01 /15/2020 PVC CONDENSATE DRAIN/REFRIGERANT PIPING 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 GALVANIZED CLAMP ELECTRICAL POWER CONNECTION, 120 VOLTS O GALVANIZED THREADED ROD HEATING CABLE TEMPERATURE CONTROLLER ®0000 SECURE SUPPORT WITH N SCB-07 SECURITY BRACKET PROVIDE MANUFACTURER'S SECURE EACH 000���o o RECOMMENDED ATTACHMENTS BRACKET WITH SHEET ���oo�000 BLACK UV STABILIZED � � ® POLYPROPYLENE COPOLYMER BODY AT 6" O.C. (TYPICAL) x METAL SCREW. o0000000000o PIPINGWITH STRUCTURAL FOAM BASE. w MANUFACTURED BY "ROOF TOP BLOX". x o 0 SYSTEM SPACING ------ �^ 9" CONDENSATE PVC 4-0" ON CENTERS ELECTRICAL HEATING CABLE (PVC) STRAPPED TO UNDERSIDE OF eY ¢ REFRIGERANT (COPPER) 6'-0" ON CENTERS PIPE. PROVIDE 20 WATTS/FOOT. ti 9" STAINLESS STEEL ALUMINUM HOSE CLAMP JACKET PRIME SURFACE WITH PRI-13 PRIMER. SECURE TO PIPE INSULATION w ROOF SURFACE WITH ADH-12 STRUCTURAL ADHESIVE. NOTE: (� w O PROVIDE LINE SENSING THERMOSTAT. ATTACH BULB DIRECTLY TO PIPING. NOTE: SLOPE CONDENSATE PIPE AT 1/4 PER FOOT MINIMUM. O z w PIPING SUPPORT DETAIL HEAT TRACE CABLE DETAIL N NOT TO SCALE NOT TO SCALE DUCT THRU ROOF CURB DETAIL NOT TO SCALE ACFM Y ZSD CCFMxY=X A CFM VD C LESS THAN 12" sVD D ROUND DUCT TAKEOFF FROM RECTANGULAR MAIN HIMM ACF Y K A- C CFMxY=X A CFM D C MORE THAT COUNTERFLASHING COLLAR SCREWED AND SEALED TO DUCTWORK CURB CAP SCREWED TO ROOF CURB REFER TO ARCHITECTURAL DRAWINGS FOR ROOF CURB INFORMATION ROOF FLASHING 0° Y W2 R1= (X+Y)/2 R1= (W 14- W )/2 2 R2= X+Y R2= W f W 2 X OR W LESS THAN 12" BRANCH TAKEOFFS 900 TEES NOTE: ABOVE APPLY TO SUPPLY AND RETURN RETURN ONLY PREFERRED OFFSET FULL RADIUS WHERE POSSIBLE =-` RD OFFSETS R2= X+Y D LESS THAN 12" X OR Y LESS THAN 12" FOR D OF 12" OR MORE USE VANED ELBOW. 900 RADIUS ELBOWS OSED CELL ENE" FOAM BLOCK, NIZED STRUT INSERT �TURED BY "PIPE PIER" SECU SUPP 1/4" G FLAT ROOF MOUNTED CONDENSING UNIT DETAIL NOT TO SCALE (TYPICAL FOR CU-1) DUCTWORK CONSTRUCTION REQUIREMENTS SYSTEM PRESSURE CLASS SEAL CLASS SUPPLY AIR +1.0" WG CLASS A RETURN AIR -1.0" WG CLASS B NOTE: 1. CONSTRUCT ALL DUCTWORK IN ACCORDANCE WITH "SMACNA" HVAC DUCT CONSTRUCTION STANDARDS. 2. PROVIDE VOLUME DAMPERS FOR EACH BRANCH DUCT SERVING SUPPLY, RETURN OR EXHAUST AIR TERMINAL. 3. ALL RECTANGULAR AND MITERED ELBOWS SHALL BE PROVIDED WITH TURNING VANES. COIL DRAIN PAN UNIONS (TYP) CLEANOUT (TYP) "H11 7RUNSLOPE TO NEAREST ROOF DRAIN 1. "H" _ (1" FOR EACH 1" OF MAXIMUM NEGATIVE STATIC PRESSURE) + 1". 2. "J" = HALF OF H. 3. "L" = H + J + PIPE DIAMETER + INSULATION. 4. SIZE TRAP IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. COIL CONDENSATE TRAP DETAIL NOT TO SCALE (NEGATIVE PRESSURE) ROOF MOUNTED DU(Tlnirinv GALVANIZED STRUT RECYCLED RUBBER NOTE: DUCT SUPPORTS SPACED A MAXIML APART WEATHERPROOF COATING AS INDICATED ON "EXTERIOR DUCTWORK INSULATION AND XniE:nTuE:omonr�E: DETAIL 1. AW SUPPORT w QU) � w O Z °5 W � 75 n w - J � Z C) W L1J = W � w Uw J w U) � Z C) O 0m o LL Q Z > Z D O U W ry Q W m J Q J_ Q W 0 J U z w REVISIONS MARK DESCRIPTION DATE COMM. NO: 19105 DESIGNED BY: JLR DRAWN BY: TGO CHECKED BY: - LOW VELOCITY SINGLE WALL DUCTWORK DETAILS NOT TO SCALE © COPYRIGHT THOMPSON CONSULTING ENGINEERS REFER TO DUCTWORK CONSTRUCTION REQUIREMENTS EXTERIOR DUCT SUPPORT DETAIL NOT TO SCALE (TYPICAL FOR KMAU-1) M201 DATE: 01 /15/2020 65% OWNER REVIEW ELECTRICAL LEGEND: 0 EXISTING 2' X 4' LIGHT FIXTURE. ® EXISTING CEILING MOUNTED EXIT LIGHT FIXTURE. ® NEW V X 4' LIGHT FIXTURE. O❑ NEW 2' X 2' LIGHT FIXTURE. 0 LIGHT FIXTURE TYPE INDICATOR. SEE LIGHT FIXTURE SCHEDULE ON THIS DRAWING. QS EXISTING CEILING MOUNTED SPEAKER. O EXISTING CEILING MOUNTED FIRE ALARM SYSTEM SMOKE DETECTOR. 10 DEMOLITION NOTE INDICATOR. 1O 1❑ NEW WORK NOTE INDICATOR ❑�3P 30 3R DISCONNECT SWITCH - 600V, U.O.N. 3P = NUMBER OF POLES, 30 = SWITCH RATING, 20 PROVIDE IN NEMA 1 ENCLOSURE IF INSTALLED INDOOR AND NEMA 3R IF INSTALLED OUTDOORS, U.O.N. OE ELECTRICAL CONNECTION TO EQUIPMENT. 0 JUNCTION BOX, SIZE PER NEC. ® PANELBOARD, 208Y/120 VOLT. CONDUIT RUN CONCEALED. BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. NO TICK MARKS INDICATES 2 #12 CONDUCTORS & 1#12 GROUND IN 1/2" CONDUIT U.O.N. TICK MARKS, WHEN SHOWN, INDICATE NUMBER OF CONDUCTORS IF OTHER THAN THREE: (7) INDICATES GROUNDING CONDUCTOR. A4-20 to HOMERUNS TO PANEL. PANEL & CIRCUIT DESIGNATIONS AS INDICATED. wP,GFI DUPLEX RECEPTACLE, 20A, 120V. INSTALL +18" A.F.F. TO CENTER OF RECEPTACLE, U.O.N. "GFI" WHEN USED INDICATES GROUND FAULT INTERRUPTER. "WP" WHEN USED INDICATES WEATHER RESISTANT RECEPTACLE WITH WEATHERPROOF WHILE IN USE ENCLOSURE. SM 20A SINGLE POLE MOTOR RATED SNAP SWITCH. O7 TO KMAU-1 CONTROL PANEL O5 TO KMAU-1 FAN O4 TO KEF-1 �9 3P 35 3R 9❑ 3P 250 3R 13 K1-16,18,20 (KEF-1),4—�fff—� I 11 PANEL "M1" (KMAU-1 FAN) I I 2] PANEL "K1" (KMAU-1 CONTROLS) 4 KITCHEN HOOD CONTROL WIRING DIAGRAMO NOT TO SCALE KITCHEN HOOD WIRING DIAGRAM NOTES GENERAL NOTES: 1. PAINT ALL EXPOSED CONDUIT TO MATCH THE SURFACE TO WHICH ATTACHED IF THE SURFACE IS PAINTED. 2. COORDINATE WITH MECHANICAL DRAWINGS FOR EXACT LOCATION OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS INCLUDING EXACT POINT OF ELECTRICAL CONNECTION. MAKE ADJUSTMENTS TO CONDUIT ROUTING, PLACEMENT OF DISCONNECT SWITCHES AND STARTERS AS REQUIRED. 3. PROVIDE NEW TYPED PANEL INDEX CARDS IN EXISTING PANELBOARDS WHERE CIRCUITS HAVE BEEN MODIFIED BY THIS PROJECT. PROVIDE COPIES OF MODIFIED PANEL INDEX CARDS ON AS -BUILT DRAWINGS AND INCLUDE IN OPERATION AND MAINTENANCE MANUALS. 4. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE CONSTRUED TO MEAN CONDUIT AND CONDUCTORS. 5. EXISTING FIRE ALARM CONTROL PANEL IS LOCATED IN MAIN OFFICE AND IS A SIEMENS MODEL FS-250. ALL WORK ASSOCIATED WITH THE FIRE ALARM SYSTEM SHALL BE PERFORMED BY A CERTIFIED SIEMENS TECHNICIAN. THE FIRE ALARM SYSTEM MUST BE OPERATIONAL AT THE END OF EACH WORK DAY. UNDER NO CIRCUMSTANCES SHALL THE BUILDING BE WITHOUT FIRE ALARM PROTECTION OVERNIGHT. 6. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE THE POWER OUTAGE REQUIRED TO PERFORM ALL WORK, COORDINATE WITH THE OWNER'S REPRESENTATIVE AND DOMINION VIRGINIA POWER, IT REQUIRED, PRIOR TO BEGINNING ANY WORK. 1O CONNECT NEW KITCHEN FIRE SUPPRESSION SYSTEM AND NEW HOOD CONTROL PANEL TO EXISTING FIRE ALARM CONTROL PANEL LOCATED IN THE MAIN OFFICE. COORDINATE REQUIREMENTS WITH EXISTING FIRE ALARM SYSTEM MANUFACTURER AND THE NEW HOOD CONTROL PANEL MANUFACTURER. O2 PROVIDE ELECTRICAL CONNECTION TO KITCHEN HOOD CONTROL PANEL AND LIGHTS. O3 COORDINATE CIRCUITRY REQUIREMENTS WITH HOOD CONTROL PANEL PROVIDED AND IF DIFFERENT FROM THAT SHOWN ABOVE MAKE ALL ADJUSTMENTS REQUIRED. SEE "PARTIAL ROOF PLAN - ELECTRICAL NEW WORK" ON SHEET E2.2 FOR ADDITIONAL INFORMATION. O4 PROVIDE ELECTRICAL CONNECTION TO KEF-1 VIA KITCHEN HOOD CONTROL PANEL. O5 PROVIDE ELECTRICAL CONNECTION TO KMAU-1 FAN VIA KITCHEN HOOD CONTROL PANEL. © TO OPERATING COIL OF NEW POWER CONTACTORS PROVIDED BY NEW WORK NOTE NUMBER 16. 07 PROVIDE ELECTRICAL CONNECTION TO KMAU-1 CONTROL PANEL. GENERAL FIRE ALARM SYSTEM NOTES 1. THE EXISTING FIRE ALARM SYSTEM AT BROWNSVILLE ES IS A CERBERUS PYROTRONICS MXL-IQ ADDRESSABLE SYSTEM. PROVIDE PROGRAMMING REQUIRED TO ADD NEW DEVICES AND DELETE REMOVED DEVICES. FIRE ALARM PANEL IS LOCATED IN THE MAIN OFFICE. 2. A CERTIFIED CERBERUS PYROTRONICS FIRE ALARM SYSTEM TECHNICIAN MUST PERFORM ALL MODIFICATIONS TO THE BUILDING FIRE ALARM SYSTEM. NO SUBSTITUTIONS TO ANY REQUIRED FIRE ALARM SYSTEM EQUIPMENT WILL BE CONSIDERED. THE FIRE ALARM SYSTEM MUST BE OPERATIONAL AT THE END OF EACH WORKING DAY. UNDER NO CIRCUMSTANCES SHALL THE BUILDING BE WITHOUT FIRE ALARM PROTECTION OVERNIGHT. THE CONTRACTOR SHALL COORDINATE ANY AND ALL COMMUNICATIONS WITH SIMPLEX. PANEL "K1"()2❑ GENERAL DEMOLITION NOTES: 1. PERFORM ALL REQUIRED DEMOLITION TO COMPLY WITH THE SCOPE AND INTENT OF THE PROJECT. REMOVE ALL WIRING ASSOCIATED WITH THE REQUIRED DEMOLITION BACK TO POINT OF ORIGIN OR LAST DEVICE TO REMAIN. 2. VERIFY ALL CIRCUITS SAVED DURING DEMOLITION FOR REUSE AS TO WIRE SIZE AND POINT OF ORIGIN. 3. EXERCISE CARE IN REMOVING MATERIAL AND EQUIPMENT DURING DEMOLITION. REPAIR ANY DAMAGE TO EXISTING SURFACES OR EXISTING SURFACES OR EXISTING EQUIPMENT TO REMAIN TO THE SATISFACTION OF THE ARCHITECT AND OWNER AT NO ADDITIONAL COST TO THE OWNER. 4. PROVIDE THE OWNER WITH FIRST RIGHT OF REFUSAL FOR ALL ELECTRICAL EQUIPMENT BEING REMOVE AS A PART OF THIS CONTRACT AND NOT SCHEDULED FOR REINSTALLATION. ALL ELECTRICAL EQUIPMENT NOT TURNED OVER TO THE OWNER SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. 5. BEFORE BEGINNING ANY WORK, FIELD VERIFY THE WORKING CONDITION OF FIRE ALARM DEVICES SCHEDULED FOR REMOVAL AND REINSTALLATION. NOTIFY THE OWNER OF ANY DEFECTIVE EQUIPMENT. AFTER THE REINSTALLATION OF EQUIPMENT, RE -VERIFY THE WORKING CONDITION. REPLACE ANY EQUIPMENT FOUND DEFECTIVE AFTER REINSTALLATION, WHICH WERE WORKING PRIOR TO REMOVAL WITH EQUIPMENT TO MATCH EXISTING AT NO ADDITIONAL COST TO THE OWNER. 6. PROVIDE ALL ELECTRICAL DEMOLITION WORK NECESSARY TO INSTALL NEW WORK. REROUTE AND RECONNECT ANY CIRCUIT THAT IS REQUIRED TO REMAIN IN USE BUT INTERFERES WITH NEW CONSTRUCTION. 7. CONDUITS MAY BE ABANDONED IN WALLS AND BELOW FIRST FLOOR SLABS ONLY. REMOVE ALL WIRING FROM ABANDONED CONDUITS. DISCONNECT CONDUCTORS FROM ALL POWER SOURCES AND PROVIDE BLANK COVERPLATES ON ALL ABANDONED OUTLET BOXES. 8. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE CONSTRUED TO MEAN CONDUIT AND CONDUCTORS. 9. EXISTING CONDITIONS ILLUSTRATED HAVE BEEN DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND LIMITED NON-INVASIVE FIELD INVESTIGATION. CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO COMMENCEMENT OF WORK, COORDINATE AND MAKE ADJUSTMENTS AS NECESSARY. ABBREVIATIONS: A,AMP AMPERE CU CONDENSING UNIT EF EXHAUSTFAN GFI GROUND FAULT INTERRUPTER IU INDOOR UNIT K KITCHEN MAU MAKEUP AIR UNIT MTD MOUNTED NO. NUMBER 0 PHASE RTHP ROOFTOP HEAT PUMP RTU ROOFTOP UNIT U.O.N. UNLESS OTHERWISE NOTED W WIRE WP WEATHERPROOF 0 LIGHT FIXTURE SCHEDULE SYM MANUFACTURER'S CATALOG No. voLTF LAMPS MOUNTING REMARKS 1 LEDALITE 9414D1CRLB44S7DE 120 (1) 4400 LUMEN LED SURFACE 2 LEDALITE 9422D1CRLB44S7DE 120 (1) 4400 LUMEN LED SURFACE NOT FOR CONSTRUCTION 01-15-20 w Qcn ry n w O Z °6 W U) 75 � w — J � Z C) W L1J = W � w Uw _j w U) U) Z 0 Q 0 O mLL Q Z cD Z D O U LLI Q W 00 J Q REVISIONS MARK I DESCRIPTION I DATE COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - © COPYRIGHT THOMPSON CONSULTING ENGINEERS EOm 1 DATE: 01 /15/2020 DEMOLITION NOTES (THIS DRAWING ONLY) O DISCONNECT ELECTRICAL CONNECTION TO FREEZER. REMOVE BRANCH CIRCUITRY BACK TO PANEL "B-2". REMOVE CIRCUIT BREAKER. 65% OWNER REVIEW NEW WORK NOTES (THIS DRAWING ONLY) NOT FOR 1❑ INSTALL DISCONNECT SWITCH ON NON -REMOVABLE PANEL OF THE WALK-IN CONSTRUCTION FREEZER. COORDINATE EXACT LOCATION WITH EQUIPMENT SUPPLIER. 1 01-15-20 O DISCONNECT ELECTRICAL CONNECTION TO THRU-WALL EXHAUST FAN. REMOVE ❑ EXISTING PANELBOARD "B-2" IS A G.E. TYPE NLAB, 208Y/120V, 30, 4W, 225A M.L.O. BRANCH CIRCUITRY BACK TO PANEL "B-2". LABEL CIRCUIT BREAKER AS "SPARE". PANEL. REMOVE SPARE 30A-3P CIRCUIT BREAKER 32,34,36. PROVIDE A NEW 15A-2P AND 20A-1 P CIRCUIT BREAKERS IN BLANK SPACE. PROVIDE A NEW 45A-2P AND 20A-1 P O REMOVE SURFACE MOUNTED EXTERIOR LIGHT FIXTURE. PROVIDE BLANK CIRCUIT BREAKERS IN BLANK SPACES CREATED BY DEMOLITION NOTE 1. Uj COVERPOATE ON EXISTING OUTLET. MAINTAIN BRANCH CIRCUITRY TO EXISTING N LIGHT FIXTURES. 3❑ PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 20A-1 P CIRCUIT BREAKER IN EXISTING PANEL "B-2". ® EXISTING TO REMAIN. ® PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 15A-2P CIRCUIT ' N BREAKER IN EXISTING PANEL "B-2". U) w N� x 5❑ PROVIDE 2 #8 AND 1 #10 GROUND IN 3/4" CONDUIT TO A SPARE 45A-2P CIRCUIT "13-2". e� BREAKER IN EXISTING PANEL 6 ❑ INSTALL DISCONNECT SWITCH ON NON -REMOVABLE PANEL OF THE CONDENSING UNIT. COORDINATE EXACT LOCATION WITH EQUIPMENT SUPPLIER. 7 PROVIDE ELECTRICAL CONNECTION TO INDOOR UNIT. ® PROVIDE ELECTRICAL CONNECTION TO FREEZER/COOLER LIGHTS. PROVIDE 2 #12 z AND 1 #12 GROUND IN 1/2" CONDUIT TO A NEW 20A-1 P CIRCUIT BREAKER IN EXISTING w O PANEL "D-2" LOCATED IN SHOP AREA. SEE DRAWING E1.2 FOR ADDITIONAL z w INFORMATION. r l W ELECTRICAL DEMOLITION FLOOR PLAN (JOUETT MS SCALE: 1/8" = V-0" ELECTRICAL NEW WORK ROOF PLAN (JOUETT MS SCALE: 1/8" = V-0" w 0 Q CD 0 W W U i w U) L w O 06 C) w J z w u w w J J i z 3: m z D O U w ry Q ry w m J Q V ) I..L O O u- v ry O z 0 z Q z O J O 7. w Q U_ w J w w 7) O 1 REVISIONS 1 1 MARK I DESCRIPTION I DATE 1 COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - El ol ELECTRICAL NEW WORK FLOOR PLAN (JOUETT MS SCALE: 1/8" = V-0" © COPYRIGHT THOMPSON CONSULTING ENGINEERS KEY PLAN (JOUETT MS' NOT TO SCALE DATE: 01 /15/2020 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 m N � W � zv 0 W SHOP AREA --4 w �- w STORAGE STORAGE OUTSIDE w x DRY FOOD STORAGE O z w STORAGE w a N [� 2❑ EXISTING PANEL "A-4" 2❑ EXISTING PANEL "B-2" A135 SHOP AREA Q \ Z KITCHEN W 0 U) A128 Q 0 EXISTING PANEL "D-2" V Q W J O � Ax ZW IL W U) � 0 � W � W Z z �\cy W Q W � w W U w A129 U W_j U) w J 2 j LLJ Cn w C� z >- o p0 z Ory ELECTRICAL NEW WORK FLOOR PLAN (JOUETT � MS oo ° o SCALE: 1/4" = 1'-0" W U. W m J Q NEW WORK NOTES (THIS DRAWING ONLY) 1❑ EXISTING PANELBOARD "D-2" IS A G.E. TYPE NLAB, 208Y/120V, 30, 4W, 225A M.L.O. PANEL. PROVIDE TWO (2) 20A-1 P CIRCUIT BREAKERS IN BLANK SPACES FOR NEW COOLER AND FREEZER LIGHT CIRCUITS. SEE DRAWING E1.1 FOR ADDITIONAL INFORMATION. EXISTING REUSED. REVISIONS MARK DESCRIPTION DATE COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - KEY PLAN (JOUETT MS) El 02 NOT TO SCALE DATE: 01 /15/2020 © COPYRIGHT THOMPSON CONSULTING ENGINEERS ELECTRICAL DEMOLITION FLOOR PLAN (HENLEY MS SCALE: 1/4" = V-0" DEMOLITION NOTES (THIS DRAWING ONLY) 10 DISCONNECT ELECTRICAL CONNECTION TO FREEZER. REMOVE BRANCH CIRCUITRY BACK TO PANEL "KP". REMOVE CIRCUIT BREAKER. O DISCONNECT ELECTRICAL CONNECTION TO THRU-WALL EXHAUST FAN. REMOVE BRANCH CIRCUITRY BACK TO PANEL "KP". LABEL CIRCUIT BREAKER AS "SPARE". O REMOVE SURFACE MOUNTED EXTERIOR LIGHT FIXTURE. PROVIDE BLANK COVERPOATE ON EXISTING OUTLET. MAINTAIN BRANCH CIRCUITRY TO EXISTING LIGHT FIXTURES. ® EXISTING TO REMAIN. 0 DISCONNECT ELECTRICAL CONNECTION TO WALK-IN FREEZER LIGHTS. SAVE BRANCH CIRCUITRY AND CIRCUIT BREAKER FOR REUSE. ELECTRICAL NEW WORK FLOOR PLAN (HENLEY MS SCALE: 1/4" = V-0" ELECTRICAL NEW WORK ROOF PLAN (HENLEY MS SCALE: 1 /8" = V-0" NEW WORK NOTES I Ir AT-rM Alter flf-%A ITn/%I I r-rl (THIS DRAWING ONLY) 1❑ INSTALL DISCONNECT SWITCH ON NON -REMOVABLE PANEL OF THE FREEZER CONDENSING UNIT. COORDINATE EXACT LOCATION WITH EQUIPMENT SUPPLIER. EXISTING PANELBOARD "KP" IS AN EATON TYPE P1 RL, 208Y/120V, 30, 4W, 225A M.L.O. PANEL. PROVIDE A NEW 45A-2P AND 20A-1 P CIRCUIT BREAKERS IN BLANK SPACES CREATED BY DEMOLITION NOTE 1. PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 20A-1 P CIRCUIT BREAKER IN EXISTING PANEL "KP" FOR FREEZER INDOOR UNIT IU-1. ® PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 15A-2P CIRCUIT BREAKER IN EXISTING PANEL "XX2". SEE DRAWING E-1.4 FOR ADDITIONAL INFORMATION. 0 PROVIDE 2 #8 AND 1 #10 GROUND IN 3/4" CONDUIT TO A SPARE 45A-2P CIRCUIT BREAKER IN EXISTING PANEL "KP" FOR COOLER CONDENSING UNIT CU-1. © INSTALL DISCONNECT SWITCH ON NON -REMOVABLE PANEL OF THE CONDENSING UNIT. COORDINATE EXACT LOCATION WITH EQUIPMENT SUPPLIER. PROVIDE ELECTRICAL CONNECTION TO FREEZER/ COOLER INDOOR UNIT. ® PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 20A-1 P CIRCUIT BREAKER IN EXISTING PANEL "XX2" FOR FREEZER LIGHTS. SEE DRAWING E-1.4 FOR ADDITIONAL INFORMATION. 0 PROVIDE ELECTRICAL CONNECTION TO COOLER LIGHTS. CONNECT TO EXISTING BRANCH CIRCUITRY SAVED DURING DEMOLITION. 10 PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 20A-1 P CIRCUIT BREAKER IN EXISTING PANEL "XX2" FOR COOLER INDOOR UNIT IU-1. SEE DRAWING E-1.4 FOR ADDITIONAL INFORMATION. 11 PROVIDE 2 #12 AND 1 #12 GROUND IN 1/2" CONDUIT TO A SPARE 20A-1 P CIRCUIT BREAKER IN EXISTING PANEL "XX2" FOR FREEZER CONDENSING UNIT CU-2 HEAT TRACE. SEE DRAWING E-1.4 FOR ADDITIONAL INFORMATION. U) 73 I- I- W O 06 U) W J z W v6 w 65% OWNER REVIEW NOT FOR CONSTRUCTION w 0 ry CD 0 W W U i w 01-15-20 z �0�/ I.J\_ z D O U J Q W m J Q 0 n 0. O O ILL Y O z 0 Q z O I= J O 73 0 Q U_ W W LLI z LLI 1 REVISIONS 1 1 MARK I DESCRIPTION I DATE 1 COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - El 03 © COPYRIGHT THOMPSON CONSULTING ENGINEERS KEY PLAN (HENLEY MSS NOT TO SCALE DATE: 01 /15/2020 65% OWNER REVIEW NOT FOR CONSTRUCTION 01-15-20 N � W n � w x l Ln SHOP AREA `-A wLn STORAGE STORAGE FREEZER DRY FOOD STORAGE OUTSIDE w STORAGE O w x O w a CORRIDOR MECHANICAL EQUIPMENT ROOM SHOP AREA KITCHEN EXISTING PANEL "A" 2❑ EXISTING PANEL "KP" EXISTING PANEL "XX2" z 1(D W � o U) L.L � i H z w Q w � O � O 06 i Zco Y W � O G � � � W ELECTRICAL NEW WORK FLOOR PLAN (HENLEY MS) wJ SCALE: 3/16" = 1'-0" D z z C) W Q W ry U) U W W w UW w -J >J U) ��>^^ w v! J C� z 3: � z w NEW WORK NOTES (THIS DRAWING ONLY) Q O z z D 1❑ EXISTING PANELBOARD "XX2" IS A SIEMENS TYPE P1, 208Y/120V, 30, 4W, 250A M.L.O. O 0 PANEL. PROVIDE A ONE (1) 15A-2P AND THREE (3) 20A-1 P CIRCUIT BREAKERS IN o m U BLANK SPACES FOR NEW COOLER AND FREEZER EQUIPMENT. SEE DRAWING E1.3 W FOR ADDITIONAL INFORMATION. U. J 2❑ EXISTING REUSED. Q W m J Q REVISIONS MARK DESCRIPTION DATE A COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - f-L KEY PLAN (HENLEY MS) El • 4 NOT TO SCALE DATE: 01 /15/2020 © COPYRIGHT THOMPSON CONSULTING ENGINEERS 65% OWNER 0 0 REVIEW CLOSET TOILET NOT FOR CONSTRUCTION 01-15-20 i � m N ON Ln c:::D GIRLS TOILET BOYS TOILET x � PANEL "D" MECHANICAL EQUIPMENT j PANEL "D" - W CD C \y EF PANEL "D" 0 KEF KEF w 10 PANEL "D" O Q 5 (TYPICAL) O w a 10 PANEL "E" O PANEL "D" O PANEL O O E 7F I j �I II 1 1 I I O O I I I I I I I SERVING CLOSET �I I-----� O �L------ I 1 1 O HOOD Q OS Q 3 Q KITCHEN O TOILET Q Q Q 1 O O EF CAFETERIA E r SOFFIT Q 0 Q O O O O O z F 0 O � ROOF \\ OFFICE W / PANEL D Q Q Q O Li H U) e® Q L � n PANEL "D" v W w � ELECTRICAL DEMOLITION ROOF PLAN (BROWNSVILLE MS) o O O SCALE: 1/4" = V-0" -j STORAGE GARBAGE DISHWASHER 7 �06 z L J O W VJ O O 2 O Li HW w o z Q cy W v W � U LLJ W � J w w THIS DRAWING ONLY w U) DEMOLITION NOTES ( ) J � 10 EXISTING TO REMAIN. '/J LLJ / J fl J O2 DISCONNECT ELECTRICAL CONNECTION TO KITCHEN HOOD. REMOVE BRANCH CIRCUITRY W (n > BACK TO INDICATED PANEL. LABEL CIRCUIT BREAKER AS "SPARE". z z 03 REMOVE CEILING MOUNTED SPEAKER AND SAVE FOR REUSE. SAVE ALL SPEAKER BRANCH 3 ~O ELECTRICAL DEMOLITION FLOOR PLAN (BROWNSVILLE MS) CIRCUITRY FOR REUSE. O D 0� SCALE: 1 /4" = V-0" O ry O m ® DISCONNECT ELECTRICAL CONNECTION TO CEILING MOUNTED RECEPTACLE. REMOVE o U BRANCH CIRCUITRY BACK TO INDICATED PANEL. LABEL CIRCUIT BREAKER AS "SPARE". W U. J O5 DISCONNECT ELECTRICAL CONNECTION TO LIGHT FIXTURE. REMOVE LIGHT FIXTURE AND TURN OVER TO OWNER. REMOVE BRANCH CIRCUITRY BACK TO PANEL INDICATED. LABEL Q CIRCUIT BREAKER AS "SPARE". © DISCONNECT ELECTRICAL CONNECTION TO MECHANICAL EQUIPMENT. REMOVE BRANCH W CIRCUITRY BACK TO PANEL INDICATED. LABEL CIRCUIT BREAKER AS "SPARE". J Q REVISIONS MARK DESCRIPTION DATE COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - KEY PLAN (BROWNSVILLE ES) El 05 NOT TO SCALE DATE: 01 /15/2020 © COPYRIGHT THOMPSON CONSULTING ENGINEERS 65% OWNER � REVIEW CLOSET TOILET NOT FOR CONSTRUCTION 01-15-20 -------------------------- --- II II �-� II cV rn U) N� �cD 7 f:�, GIRLS TOILET BOYS TOILET CD e� O I- - -I � x I - I I MECHANICAL EQUIPMENT b'0 L J LLo EF C:D c::D' N ON Lo EXISTING PANEL "D" ® Z w -------------------- r , I��III II I��I II II II I ----- - ----- EXISTING PANEL "E" O — O — — — — — — — O �1 O J� �J O O II CD�' SERVING KMAU-1 CLOSET EF 0 Li O O O EF TOILET O O ul ]ALP ' CAFETERIA 0 O O Q O O O O O z O � OFFICE I I w O O i /'i OL—j Li ------� Q `�� U) � Q (D I0. w F ELECTRICAL NEW WORK ROOF PLAN (BROWNSVILLE MS) D o O O 11 O SCALE: 1/4" = 1'-0" i STORAGE � \ —3 ILL r3ishZ GARBAGE � z �/� O w v! O O O n w w D Z Q 6"o DN C) w U 8"o UP = 10� ui .. ~ (n W w w J Lu U w c) 2 > J w / J J_ LLl U) > U) Cn z > z ELECTRICAL NEW WORK FLOOR PLAN (BROWNSVILLE MS) 0 O D ° SCALE: 1 /4" = 1'-0" O ry 0 m o m U LL J Q w m Q REVISIONS MARK DESCRIPTION DATE COMM. NO: 19105 DESIGNED BY: JNF DRAWN BY: MWH CHECKED BY: - KEY PLAN (BROWNSVILLE ES) El • 6 NOT TO SCALE DATE: 01 /15/2020 QC COPYRIGHT THOMPSON CONSULTING ENGINEERS IIII� I��I� INTERNATIONAL COLD STORAGE ICS walk-in exteriors are, as standard, a tough stucco embossed metal, with a factory baked on polyester coating, that provides years of maintenance free service. This finish exceeds the standards for durability established by food service systems, who have enjoyed the economy and flexibility provided by ICS one-piece construction for many years. The wide range of color options makes it easy to select a finish that complements your building's color scheme. Polar White Almond Autumn Brown Mist Gray Sand Colonial Red Taupe Bronze Technical Specifications: Coating thickness .8 mil • Curing temperature 4350F hardness (pencil) F minimum • FDA approved pigments • Excellent resistance to salt spray, humidity and chemicals Cold Storage Solutions" For customers wishing to apply color finishes to walk-ins themselves, Sherwin Williams' paint formulas are detailed below. Representations of the colors below are restricted by the commercial printing process. For accurate color renditions, please contact your local Sherwin Williams' representative. Polar White Mist Gray CCE Color Cast Oz 32 64 128 CCE Color Cast Oz 32 64 128 G2 New Green - 1 - Bl Black - 7 - - Nl Raw Umber 1 1 R2 Maroon - - 1 1 R3 Magenta 1 - Y3 Deep Gold - 6 - 1 Autumn Brown Colonial Red CCE Color Cast Oz 32 64 128 CCE Color Cast Oz 32 64 128 B1 Black 17 1 - W1 White - 11 - 1 N1 Raw Umber 54 1 1 L1 Blue - 10 - 1 R2 Maroon 7 - 1 R2 Maroon - 25 1 1 R3 Magenta - 32 - 1 CCE Color Cast Oz 32 64 128 Architectural Finishes W1 White 52 1 1 ICS can also prepare your equipment for B1 Black 6 - 1 direct attachment of other architectural finish R2 Maroon 1 1 - systems or we can supply a finish system using Y3 Deep Gold 19 - - a variety of cementitious boards from nationally Taupe respected building materials suppliers. —0 For further details, please visit www.nichiha.com CCE Color Cast Oz 32 64 128 B1 Black 8 - - - R2 Maroon 2 - 1 Y3 Deep Gold 10 1 - Canyon Brick Shale Brow Sandstone Desert Beige CCE Color Cast Oz 32 64 128 Ll Blue - 1 - T R4 New Red - 4 - 1 Y3 Deep Gold 10 - 1 Sandstone Gentle Gray Vintage Brick Alexandria Buff BAC Color Cast Oz 32 64 120 Bl Black 2 20 - lil�i� �Illl INTERNATIONAL R2 Maroon - 6 6 - COLD STORAGE Y3 Deep Gold - - G2 New Green - 12 - - lil��� ��Ill