Loading...
HomeMy WebLinkAboutSDP201800016 Plan - Approved Minor Amendment 2019-09-03KESWICK HALL ADDITIONS AND SITE IMPROVEMENTS MINOR SITE PLAN AMENDMENT SDP-2018-016 NOTES TAX MAP PARCEL AND OWNER INFO: EXISTING ZONING: MAGISTERIAL DISTRICT: EXISTING AREA: PARCEL 08000e00= M0900 HISTORIC HOTELS OF ALBEMARLE LLC 701 CLUB DRIVE KESWICK, VA 22947 PARCEL 08000-00-00-008ZO KESWICK CLUB LLC 701 CLUB DRIVE KESWICK, VA 22947 RA - RURAL AREA SPECIAL USE PERMIT SP2018-001 RIVANNA PARCEL 08000-00-00-00900 = 6.92 AC. PARCEL 08000-00-00-008ZO = 161.66 AC. EXISTING IMPERVIOUS AREA: 2.74 AC PROPOSED IMPERVIOUS AREA: 5.48 AC LIMITS OF DISTURBANCE: 9.95 AC SOURCE OF SURVEY, BOUNDARY, AND TOPOGRAPHY: TUCK MAPPING SOLUTION, INC. 4632 AERIAL WAY BIG STONE GAP, VA 24219 276-523-4669 PROJECT* L17-10405 INFRAMAP CORP 10365 CEDAR LANE GLEN ALLEN, VA 23059 804-550-2937 PROJECT #: RV07317 TIMMONS GROUP 28 IMPERIAL DRIVE STAUNTON, VA 24401 540-885-0920 PROJECT #: 40241 DATUM: HORIZONTAL: NAD83 VIRGINIA STATE GRID SOUTH ZONE VERTICAL: NAVD88 REQUIRED YARDS (MINIMUM): FRONT: 75 FT SIDE: 25 FT REAR: 35 FT PARKING SETBACK: 25 FT PROPOSED USE: EXISTING HALL (MAX. HEIGHT 53.13') LAUNDRY FACILITY 3,805 SF (MAX. HEIGHT 20.17') NEW GUEST WING 40,000 SF (MAX. HEIGHT 34.00') POOL BAR 300 SF (MAX. HEIGHT 16.92') RESTAURANT 3,900 SF (MAX. HEIGHT 22.00') EXISTING PARKING: 216 SPACES PARKING REQUIRED FOR NEW DEVELOPMENT: EXISTING HALL: 36 GUEST ROOMS X 1 SPACE/GUEST ROOM = 36 SPACES LAUNDRY FACILITY: 2 EMPLOYEES X 1 SPACE/PER EMPLOYEE = 2 SPACES NEW GUEST WING: 42 GUEST ROOMS X 1 SPACE/GUEST ROOM = 42 SPACES POOL BAR: 300 SF X 13 SPACES/1,000 SF GFA = 4 SPACES RESTAURANT: 3,900 SF X 13 SPACES/1,000 SF GFA = 51 SPACES TOTAL = 135 A TOTAL POST DEVELOPMENT PARKING PROVIDED: STANDARD SPACES = 131 HANDICAP SPACES = 7 (1 VAN SPACES) 1 EXISTING SPACES TO REMAIN = 109 TOTAL (2 EXIST. ADA SPACES) TOTAL SPACES = 247 LOADING SPACES PROVIDED: EXISTING LOADING SPACES PROVIDED ON THE NORTHERN & SOUTHERN SIDE OF KESWICK HALL. WETLAND IMPACTS' NONE UTILITIES: DRAINAGE DISTRICT: PRIVATE CARROLL CREEK - RIVANNA RIVER THERE ARE CRITICAL SLOPES LOCATED ON THE NORTHERN SIDE OF THE PROPERTY, DIRECTLY BEHIND THE KESWICK GOLF CLUB ON THE EASTERN SIDE OF THE PROPERTY & IN FRONT OF KESWICK HALL ON THE SOUTHERN END OF THE PROPERTY. THERE ARE NO CONSTRUCTION ACTIVITIES PROPOSED WITHIN THE 100-YR FLOODPLAIN. CRITICAL SLOPES IMPACT WAIVER SDP201800016 KESWICK HALL ADDITIONS AND SITE IMPROVEMENTS - MAJOR AMENDMENT & SDP201800017 KESWICK HALL ENERGY PLANT - MAJOR AMENDMENT SPECIAL EXCEPTION CONDITION 1. THE AREA OF LAND DISTURBANCE ON CRITICAL SLOPES SHALL NOT EXCEED 30,031 SQUARE FEET AS SHOWN ON SHEET 1 OF THE PLAN ENTITLED "KESWICK HALL ADDITIONS AND SITE IMPROVEMENTS CRITICAL SLOPES WAIVER EXHIBIT" PREPARED BY TIMMONS GROUP AND DATED JUNE 25, 2018 4•t ti.'t<::ntT COUNiTY OF ALRFMARI.F Department of Corn rnunity))cvclopment 401 cln Ir R , t1 h t' a Dart �Vnrtt \ 1 n g Charlottesville• vir•Onia 2290-4�* Phone (43a l 296-5833 Fes i t34 i 072A 11-6 my 2', 2018 W.Ihams Mullen C'iO Valere Long 121 E. Main Street, Suite 400 Charlottesville, Va 22902 RE: SP201800001 Keswick Hall and Golf Club Dear leis. hung On July 11, 2018, the Board of Supervisors tool, action on your special uce �errnit request to ;lrllend p cviuusly appiuved SP200800042 to icluc:atc and cApand the spa and I iuiess center, add a Fool bar, expand the enerU plan'., add a r.ew maintenance and laundry building, relocate the existing restaurant in r. standalone building, and add a wing to the exi\frog inn For 38 additional ro p ' morns (a total of 86 rooms). fit addition, site changes to parking and circulation are }. 1osed on t v Wax Map 1 excels 0800000000087.0: 0800(10000J6(IAO; 08000C.00t)]0900 mthe Ri anon Uis'ri,.t The Special Use pemtit x&s approved by the Rcuird's edopticn of the attached resolution and corditions. Please be a:l\is d thin allhou-,h the Albenittrle Cnunn, Board ot,upervistirs tookactiou on the 0 c u aittil all project noted ahi,\ c, uu Itses un The properly as approved abase nrn• lawfully be„ applicable approvals have betm received and conditions have been stet. "Ibis iuclud?s: • compliance with conditions of the SPECIAL USE PERMI•I approval of and compliance with a SITE PLAN or a SITE PLAN A1b1EV13MENT, and • approval of a ZONING COMPLIAANCE CLEARANCE. Rehire beginning a ws as a loved by this special use permit or if volt have question•, regardin. the oho. ; noted action, please ,ontac Rebe::ca Ragsdale at (434) 296-5832 cat. 3i26. Sincere.y, j r' Megan Nedocnrp; MCP P-incipel I'lannc- P.annin8 Division RESOLUTION TO APPRObfi Sl' 2018-01 KESWICK HALL AND COIX CLUB WBEREAS• the Otvner of Keswick Ralt fled an application to amend a previously -approved special use permit (SP 200800042) kirMm Map Parcels 08000-00-00-008Z0. 08000-00.00-060A0, and 08000-010-00-00900 to relocate and expaod the spa and fitness center, add it pout bar, expand tine ene-gy plant, add .t new maintemace and 1wirldry building, relocate the existirg restaurant to a stand alone building, ' c a est the 'e ' t ' 8 dditi nql room as well as make site h n o parking and and add a wing to floc existing inn ! tr _ a o s, g p 8 ;:irculation, anc the application is identified as Special Ilse permit 2018-00001 :Keswick Hall and Golfo: hob �"S P 20 t 8 0 1"); and WT- EREAS, on May 22, 2018, after a dt:fy noticed public hearing; the Albemarle County Planninp C:ominission recommended approval of SP 2018-01 with conditions recommended bystaff, and reco t mendcd mincr changes -o the Conceptual Plan; and WHEREAS, subsequent to the Planning Commission meeting. the Applicant submitted an uriciated Conceptual Plan dated June 11, 2018 that partially addressed the Planning C'onnmission's recommendation ahnnt change: to the ('nncrphla! P an, hnwevrr. the updated Conceptual Plan o--c-timiltei nidninnal riutnges that were noteonsicercd by -tie PlaonirgCommission; and WH rRFAS, on July 11, 2018, the Alhenlarle County Board of Supervisors hek� a duly noticed public icat'ug oil SP 2018-01. NOW, THEREFORE, BY IT RESOLVED 'hat, upon consid.ration of the foregoing. the staf- 1, • . report pteparcc! for SP 2018-01 and all of its ailachroenta, die iafurwatial prv_wliexl et thL- pu_ Ile, hearing, and the !actors relevant to a special use permit in Albemarle: County Code § 18-33.8. the Albemarle County 4 v S 1 - •t to anc con itmn. attached henan- including S e �'sors a .o es . P 20 8 0l, subject d Board of u n t hcrcb J '� P Y PP Condition 41, which references the Conceptual Plan dated June 11, 2018 and the Narrative dated January 16. 2018, updated Juts: 11, 2018. IN M � t t Foregoing writing is :t tole correct 1 ue r son do ,tereb cer.if � .ha he t t e t � c a 1 Llartde K. 3c er , I? . Y y 8 3 6 uPy Resolutio,r duty adopted by the Nmrd of Supervisors orAlhemarle County, Virginia, by a vote of fry ee to -rare, ai recorded below, at L meeting held on July 11, 2018./// Clerk:, Board of C!,unt\. AAe Nay Mr. Dill Absent Mr. GallawGy Y Ms. Mallek y Ms. McKeel Y Lis. Palmer " Mr. Randolph y COUNTY OF ALBEMARLE VIRGINIA 4/29/2019 SITE LOCATION 616 73t 0 keswick Hall FOX HILL POYAL ACRES 144 73t3 GHTS Keswick &55 gas ,. bt6 • MAGRUDER _ 744 FITZWOOD r 5e VICINITY MAP 111 = 20001 DEVELOPER: HISTORIC HOTELS OF ALBEMARLE LLC 701 CLUB DRIVE KESWICK, VA 22947 CONTACT:JOHN TREVENEN TELEPHONE: 434-923-4300 ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVE. SUITE 200 CHARLOTTESVILLE, VA 22903 CONTACT: CRAIG KOTARSKI, P.E. TELEPHONE: (434) 327-1688 SP-2018-00001 Keswick Hall and Gulf Club Conditions 1. Development and use shall ire in accord with the conceptual plan titled "Keswick Hall & Golf Club Special -Use Permit I'lar." prepared by Tian Howl rton and dated June 11, 2018 (hereafter "Conceptual r plan ), and narrative titled "Kes\vick Hall and Golf Club Project Narrative"(hercafur "AJarrative"� dated January 16, 2018, updated Juuc 11, 2H8, as detct inincd by dte Director of Planning at:d the Toping Admitustrator. 2. "he restaurant, tavern, anc: inn and accessory uses shall not consume water in excess of existing permitted capacity of the costing water system (76,000 gallons per day) and sewage system (60,000 gallons per day). if the certral water or sewerage system rrust he expanded in met eexisting or future ccmand for residential user's, the applicant shrill seek and obtain ill necessary approvals for expanding ale system from the Virginia fR:parttucnt of Health, the V i-g:nia Department of Ervirenmcntal OuAlity, and the Albemarle County Board of Supervisors. Any expansion of the central water or sewerage system to meet existing or fixture demand for residential uses shall be solely for the use of residential users. 3. The applicant shall seek and obtain all necessary approvals by the Virginia Department of Health and Albemarle County Fire Rescue Dupamauut ror a water system improveinew to support dedicated internal Eire protection w described in the "Water and Wastewater Facilities Plan 2017 Updatc for Kes\tick Hall &- Golf Club" prepared by Timmons Group dated December 1, 2017 and revised March 19,2018 (hereinafter the "2017 Water/Wastcwaler Plan") before a building permit for the proposed iraprovemerts described in Pease I A of the 201 ;' vVGterlWastewater Plan may be issued. No certificates ofcecupancy °or the improvements in Phase lA shall be issued prior to dte completion of the aforementioned Neater system intlaweux t t_ 4. The applicant shall see.,c and obtain all necessary approvals by the A1lx.tnailc County Beard of Supervisors for a \eater system improvement to support expanded permitted capacity of the water distribution s •S tout rn n . v, tom as described in the 2017 Water/V1'aslcwater Plan bel'ure nay building pemtit for the ptopaced improvements described in Phase IA of Lie afaremcatio ned plan may be issued. No certificates of occufancy for the improvements in Phase IA shall be issued prio- to the approval ofthe Virginia Deparmunt of Health, die Virginia Department of Environmental (duality, Albelr arle Ccttuny Fire Rescue Department, and completion of tie aforementioned water system itnprovernent. 5. No un latted properry shall he quhdivili i and 9n a ve u i' _ e p p pe ppro d s be tvrs�an plat shall b recorded unte;s the applicant demonstrates to the satisfaction cf the Planning Director and County Eugiu=i that tilt: crusdrg cenexl water system permitted and approved by the Virginia Department of Nealdi, or as such permit is amended or such subsequent pemtit approved by the Virginia Department of Health, Division of Water Supply Engineering and the Board of Supervisors, is available and adequate to serve all of said lots, as welt as aU existing improvements, associated uses, an9 platted lots, without compromising an -site and adjacent off -site well water ;u:ipiiec. Nothine. hnrrin shall guarantee approval of cueb ameadment or permit, In malting f-tis demonstration, the application shall use test procedures approved by the Viigiuia Department of Health and the County Erngkiccr 6. Exccpt for any restwfant and spa on the property open vi the Pellerai public, Keswick Hall and its associated facilities shall be u.wd only by tho guests of the inn and their invitecs, anc: mernt crs of the Keswick Country Club and their invitees. 7. In the event that tee use, structure or activity for which this s weial use permit is i zsuc+a is not commenced en or before July 11, 2020, it shall ae dec-ned abuudoncd and the permit tcrmmated. The term "Commenced" means "cons -ruction of any strucntre necessary to the uw of the pcnnir2. 8. All parking aneLq established or expanded after July 11, 2018 shall contply with a minimam 25-1'ont setback. 9. Keswick Road shall tx the primaiy accvss. iJ SIGNATURE PANEL: Sheet List Table Sheet Number Sheet Title C0.00 COVER C1.00 NOTES AND DETAILS ^A nA AI^Trn AAIn nrTA II n ^A nn AI^Trn AAIn nrTA I n ^A nn AI^Trn AAIn Mr -TA 11 el ^A nA _ AI^Trn AAIn nrTA 11 n ^n nn "._ n1 IrrT IAInr\/ ^n nA r\/I nTIA Ir, ^^A In I TI/•1A In ^n nn - rVl nT1A 1^ ^^A 1n ITI^\In .._a. .^.-. ^n nA rVInT1AI^ ^^AInTI^Alm rVIc rlA l^ ^^A 1nT1^A In nrAA^1 ITl^AI nl AAI r" nrAA^l ITI^AI n1 AAI ^n nn nrAA^I 1T1/••\Al MI AAI ^n nn nrAA^I ITIP\A1 nI AAI ^n An (- nrA A^I ITI^A I nl AAI `. ^n nn.' rn^nl^AI nAln nrnlA ArA1T AI^Trn AAIn nrTAll el-----..__._.-....---_...._....--r-_...._ ^n nnA .. rn^n1^AI AAIn nrnlAArAIT AI^Trn AAIn nrTA11 n ^n nA n^nl^AI AAIn nrnlAAr- I'r /•.^AITn^l n1IAnr I ^n nn rMe%e1I 1n1 AAIn nrnlAArAIT ^^A ITn^1 MI IAnr. ^n nn rn^nl^AI AAIn nrnlAArA1T ^^A ITn^1 nl Innr I ^n nA rn^n1^AI AAIn a rnlAArA1T ^^A ITn r-,I n11Anr I, ^n nr rn^nl^AI AKIn nrnlAArA1T ^^A ITn^1 n11Anr I ^n nA A rn^nI^AI AAIn nrnlAArAI-r ^^AITn^1 n1 IAnr A A ^n nnA rn^n l/\AI AAIn nr n IAArA IT nP\w 1Tn^1 nl Innr IA ^n nnA _ rn^nl^A1 AAIn nrnlAArA1T e1^AITn^I nl IAnr IA " ^n n A A rn^n 1^11I A I.In nrn lA ArA IT ^^A ITn^1 nl 1 A nr 1 A ^n nr A rn^nl^AI A 1.In nrn1A ArA1T ^^A ITn^1 nl Innr I A rn^e%I KI AAIn nrn I ArA1r r'. r\A ITn r•\1 n1 IAnr 11 rnrinlP\K1 AAIn nrnlAArA1T ^^A ITn^1 n11 Anr II ^n nn rn==1=A1 AAIn nrn IAArA IT ^^A ITn r%I n11A.nr II _ ^n nn rnrinlr\Al A\In nrnlA Ari.IT /1eNKITneN1 nI IAnr II - ^n An rn1-\n1^AI nAln nrnlAArAIT ^^AITn^1 nI IAnr II ^A nn nlTr nl AAI ^A nA nlTr nl AA1 C4.02 SITE PLAN ^A nn nlTr n1 A.A1 ^ A n A n I T r n l AKI nr nn ,., ^riAnIAI^ AAIn nnAMIA^r nl AAI ^nAn1Al^ AAIn nnAIKIAI-r- nl AAI C5.02 GRADING AND DRAINAGE PLAN ^r nn _ ^n.AnIAI^ AAIn nn AlAlA^r nl AAI ^r nA ^nAn1Al^ AAIn nnAIAIA^r MI AAI .. _ ^r nc _ ^n A nIA I^ nn^T el 1^Tn nl AAI ^r nC ^n A nlAl^ nn^T 17111^Tn nl AA1 ^r n7 ^n A nlA lel nn^T nl 1^Tn n1 A ^r nn _ ^n An1A1^ nn^T ell 1^Tn ni AAI ^r nn ^n A n1A I^ nn^T nl 1/•\Tn nl AAI ^n nn nT^nAA%A/ATrn AAAAIA^rAArA1T nl-IAAAA A nv nor nr\/rl /torn ^C nA nT^nAA%A/ATrn RAAAIAnrAArAIT I'll IAAAAAn\/ nnr nr\/rl ^nrn rl ^%At nAT1 In nT^nAA1A/ATrn AAAAIA^rAArA1T n1 IAAAAAn\/ n^nT nr\/r1 ^nrn ^/n nn nT^nA A1A/ATrn AAAAI A^rA ArA IT n11A AAA A n\/ n^nT nr\/r1 ^nrn r1 ^1A1 nATI In ^n nA nT^nAA%A/ATrn AAAAIA^rAArAIT nl IA AAA An\/ nrTAll n nrn nc nT^nAA%A/ATrn AAAAIA^rAArA1T n1 IA AR AA n\/ nrTA11 e, nT^nAA%A/ATrn ell IAAAAAr-% nl AAI ^rT n-7 „fir,.... nT^nAA1n/ATrn nrnl^AI TAnI rn AAIn ^A1 n111 ATI^Alm ^n nn nT^nAA%A/ATrn Mr -nit -AI TAnI rn AAIn ^AI ­1 11 ATl^Alm nrnAAr Anl r nA\/rn IAInTAI I A ri/ Kl .AAIn AAAIAITrAIAAInr ^n An nT^nAA1AIATrn AAAAIA^rAArAIT rA^II ITlrn r-AnrAArAI-r_1"1I AAI ^-7 nn - nn^r11 rn ^-7 nA nn^r11 rn r+ / nn nn^rn rn C7.03 PROFILES ^-7 n A _._ _ nn^ill rn nn^rn re, I TI^11 nl A11 rlr^TI^11 A1111 111Tr I A\/^1 IT DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION HEALTH DEPARTMENT TOTAL SHEETS = 70 APPROVAL DATE 1 �'! I —I ■t ■1�� Sheet List Table Sheet Number Sheet Title ,, rA1Tn\/ n^An A nA nIIIAI^ AI^nTl I nl AAI .," rA ITn\/ n^An n nA n1/IA I^ 1/111Tt I Mi AAI - .. .. nrnTA1 InAAIT 1 r\/rl nn n1 AAIM.,.,_»,� .,,a,,, ,�„ .. ._-. •- --.. . ... nrnTAI In A AITI r\/rl nA nl AAI ".T` _. -..TrnnAP - -All A•n=r\•Ar.1T ., . �•. _:n1 vrnlAn^1i 1In1 I 1mm�T nl nAl L , .v I ,� .,«.ems,... . ,�✓..I•.... , •• .�� L• .... • �• •• . " L l.vv a�4 .r... .r✓�... ,.•. ... ,.�✓ �. ,.. ids-. rA=Tnl AAI ... ,�:. . AI IA Ion\/ ALIn AA A IAITrAI A AI^r n1 AAI -, - • ...,, r11T�\, r,n „ .,w...„11,,, .I Tnrr n - ems`-�, ... , . • ...• .✓ •, :� �, .• •r .•• ..., ... ...�� r.�•�• .• . •• ..r �. •, . - • � - ^1 r 11^\r11,"•T/11"\\„1 �.- Al LV.V V 11 ^L✓T•w•✓ 1"• A`1'T T, "` • �• •, . • •, , \r • r, •• . �.•.A 1 T 1 1111"\rl"•r\Tr11'1\, 71 11 .+ . LV.TV ....*p'".:,. 1"\ ^ /1 I-• w ^ r TI", r r 1 .. ,. • vvL • �. •. •, .vim . • •�� . -. .., . r.,v • L, ... -. L V.T , 4�^t.-,""1 vA.vL v, .✓✓r1v • v. • ./ , -, •,.Tr.. v • L,A•'. LV.VV -.• ✓v • . • v. • • .• •�� t IL VT T• .•...✓ ^�• .,,T•,. v ^r, •, �w 1 . �. L3.� . 11r,AI nl Ir'r\T ,A 1111r1 rwr\T Tr.rr 1",I A11T111 .. n L3.-Z 777� LV.VV A � .✓. • vv✓v . ...•.v ✓• •✓ • v".✓✓. •✓Tv1"\\., ^L, •'.T.'.v . L, .• • "�? •-•�� L\/.•..\, TI.I " .......... ✓� •...�.. - -. ;.tea: vi .0 C. C....- I 1 1. , 3 3 • 1117r.7: 1r1T/11 . 7 ,. • r T w C• T r I I C 1 I T I 1 1 C = T w I 1 r, TOTAL SHEETS = 59 1 'r' I 0 CJ CRAIG W J. KOTARSKI Lic.:t%To. 0402048507 �„ Cs �Iiss�O1VAL ��.� M E 0 0 N U N � ¢ a > E w °' E ~ V ¢ U. o U. L UJ O ru ¢a J U seo, LU U� d > C:)p N V% N LU O5x U) J � (li = � N = U > uUr3 I_ ¢ c u' O � N >� M a � ib J � l'_ z O 0) 13% 0) Oh 0% w o 0 0 0 0 I.— rV N N N N ¢ " inl0 Oh 0h M (i, N Q 7 7 Lr) N N N 00 0 0 0 0 0 DATE 03-26-2018 DRAWN BY 1. SANDERS DESIGNED BY A. ALLISON CHECKED BY C. SHIFFLETT SCALE N/A V z W 2: W ° C 7 O L) U C N O w L u an N 0 CL CL c V 1 CD 1--1 CD z c Q (0 s t—t In C N Q LU z \ s / o U')0O° U r- zLU U _J c N a. U 0 H� W 2 O m �Z J 0 0 a o� c � CO O Q EC c c (D D u a- in O c C7 3 Z to in O (v a g x H a) O 0 O a3 m a3 c U U o L j to c O v c a) o W E c U to JOB NO. 0 o � U 40241 w ro � in c O SHEET NO. o C0.00 in L H GENERAL NOTES 1. CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR AS BUILT DOCUMENTATION, AS REQUIRED BY THE LOCALITY. THIS INCLUDES, BUT IS NOT LIMITED TO, TESTING, INSTALLATION DOCUMENTATION, SURVEY, ETC. ALL REQUIREMENTS SHALL BE DISCUSSED WITH THE LOCALITY PRIOR TO BEGINNING CONSTRUCTION. 2. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 3. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS. 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT STANDARDS. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY. 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER'S REPRESENTATIVE FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 19. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 20. THE OWNER'S REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 22. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS AND ROAD AND BRIDGE STANDARDS. 24. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF WAY. (N/A) 25. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE OF ROAD. (N/A) 26. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG-7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. (N/A) 28. CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL FOR REVIEW BY THE ENGINEER, OWNER'S REPRESENTATIVE, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 29. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON -SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2006 UNIFORM STATEWIDE BUILDING CODE, 2006 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI Al17.1-03. 30. THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 31. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. 32. ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 6" SHALL HAVE A 6:1 STONE WEDGE PLACED AT THE END OF THE DAY 33. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. HALL BE 3. EROSION AND SILTATION CONTROL MEASURES S PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND MUST BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE -w-�,- 10. RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALL EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN ALSO. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. BLASTING NOTES 1. BLASTING SHALL NOT BE PERMITTED ON THIS PROJECT. ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES 1. ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2. PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3. FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. ACSA GENERAL WATER & SEWER CONDITIONS 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 4. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 7. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 8. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. 9. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. 10. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO -LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). GENERAL CONSTRUCTION NOTES FOR EROSION AND SEDIMENT CONTROL 1. THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF -SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN APPROVING AUTHORITY. 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8. DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. 12. BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING ORDINANCE SECTION 5.1.28. 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF ALBEMARLE. 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE LIMITED TO THE HOURS OF 7:OOAM TO 9:OOPM. 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF SLIDES, SINKING, OR COLLAPSE. 16. THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER PORTION OF THE PROPERTY. 17. TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF & PROPERLY SECURED. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 18. PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND MULCH. AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 1000LBS/ACRE AND CONSIST OF A 10-20-10 NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF & PROPERLY SECURED. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 19. MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT. ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY. SILT TRAPS SHALL BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. ALL SEEDED AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE CLEANED AND REPAIRED IMMEDIATELY. 20. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS OF FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 21. THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF APPROVAL. (WATER PROTECTION ORDINANCE SECTION 17-204G.) 22. PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS WITHIN NINE (9) MONTHS AFTER THE DATE THE LAND DISTURBING ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE SECTION 17-207B) 23. NEW RETAINING WALLS 3 FEET AND HIGHER REQUIRE A SEPARATE BUILDING PERMIT. IF RETAINING WALLS ARE WITHIN MANAGED CRITICAL SLOPES, THE DESIGN MUST COMPLY WITH ALBEMARLE COUNTY CODE CHAPTER 18 SECTION 30.7.5. LEGEND ROADS SEWER TRAFFIC STOP BAR ® - - EXISTING SANITARY SEWER STORM PIPE & STRUCTURE NO. DROP INLET & STRUCTURE NO. WATER CURB CURB & GUTTER EXISTING WATER LINE DRY CURB & GUTTER 80 W PROPOSED WATER LINE PROPOSED PAVEMENT --0 .80 W PROPOSED VALVE PAVED DITCH + 8' W PROPOSED TAPPING SLEEVE - JUTE MESH DITCH PROPOSED FIRE HYDRANT (COMPLETE) CENTERLINE OF DITCH GRADING { BENCH MARK TC = TOP OF CURB . �`�� . CLEARING LIMITS C BC = BACK OF CURB EP = EDGE OF PAVEMENT --4V- R-1 VDOT STANDARD STOP SIGN TW =TOP OF WALL BW = BOTTOM OF WALL 200 EXISTING CONTOUR TS = TOP OF STAIRS BS = BOTTOM OF STAIRS 200 PROPOSED CONTOUR N/A = NOT APPLICABLE TO THIS PROJECT + 240.5 EXISTING SPOT ELEVATION TC 240.5 PROPOSED SPOT ELEVATION 1O PARKING COUNT ALBEMARLE COUNTY 1 INAL PLAN GENERAL NOTES General Construction Notes 1 . Prior to any construction within any existing public right-of-way, including connection to any existing road; a permit shall be obtained from the Virginia Department of Transportation (VDOT). "Phis plan as drawn may not accurately reflect the requirements of the permit. Where any discrepancies occur the requirements of the permit shall govern. 2. All materials and construction methods shall conform to Current specifications and standards of VDOT unless otherwise noted. 3. Erosion and siltation control measures shall be provided in accordance with the approved erosion control plan and shall be installed prior to any clearing, grading or other construction, 4. AlI slopes and disturbed areas are to be fertilized, seeded and mulched. 5. The maximum allowable slope is 2:1 (hori ontal:vertical). %iIiere reasonably obtainable, lesser slopes of 3:1 or better are to be achieved. 6. Paved, nip -rap or stabilization mat lined ditch may be required when in the opinion of the County Engineer, or- designee, it is deemed necessary in order to stabilize a drainage channel. 7. All traffic control signs shall conform with the, Virginia ManuaI for Uniform Traffic Control Devices. g. Unless otherwise noted all concrete pipe shall be reinforced concrete pipe -- Class III. 9. All excavation n for underground rc and pipe installation must comply with OSHA Standards for the Construction Industry (29 CFR Part 1926). TYPE 21-B AGGREGATE BASE COURSE COMPACTED SUBGRADE DENOTES GRAVEL SECTION ON PLANS GRAVEL SECTION No Scale EOP' CONCRETE BUMPER BLOCK ANCHOR WITH 5/8" REBAR IMBEDDED 24" IN GROUND �. HANDICAP SIGN LOCATION (TYP.) HANDICAP SIGN LOCATION (VAN) �� ® PAINTED a PER 2% MAX. -� �411 VDOT, SPEC. 18' 1 8 6.1.8' 8' 8' - TYPICAL t VAN `- ACCESSIBLE ACCESSIBLE HANDICAP SPACES TYPICAL PARKING SPACE DETAILS No Scale R= %4" EDGE OF PAVEMENT 1 4" I PAINTED STRIPE (TYPICAL) -; 9 I _ REGULAR SPACE CONTROL JOINT SPACED AT WIDTH OF WALK EXPANSION JOINT AT MAX OF 100', WITH PREMOLDED EXPANSION FILLER CONC. WALK 'd° • ..,a • 4. e d. d. b t COMPACTED SUBGRADE 4" 21-B STONE CONCRETE SIDEWALK JOINT DETAIL No Scale SIGN 1 SIGN AND POST DETAIL No Scale STD. U POST GALVANIZED POST TO BE DRIVEN RED PA M PARM PEKTY PBVALTY $M - 00 RE $M - $500 FEE TbYV AWAY ZONE TbW AWAY ZONE VAN U ABOVE ACCESSELE 6' ABOVE FINISHED FINISHED GRADE GRADE SPACES SHALL BE IDENTIFIED BY ABOVE GRADE SIGNS AS RESERVED FOR PHYSICALLY DISABLED PERSONS. PROVIDE ONE (1) R-7-8 SIGN AT EACH PARKING SPACE INDICATED ON SITE PLAN. SIGN SHALL BE ALUMINUM (PAINTED WHITE) WITH GREEN LETTERS AND INTERNATIONAL WHEELCHAIR SYMBOL. SIGN SHALL BE PLACED ON STEEL POST 1-1/2" 0 PAINTED BLACK SET IN MIN. 2' OF CONCRETE. VA. SIGN FOR THE DISABLED ON 0.80 GAUGE ALUMINUM. COLORS: GREEN BORDER & LEGEND, BLUE SYMBOL FOR ACCESSIBILITY, WHITE BACKGROUND. PARKING SIGNS FOR THE DISABLED No Scale NOTES: 1. REFER TO SITE STRUCTURAL DRAWINGS FOR FINAL EXTERIOR STAIRS & HANDRAIL DETAILS EXTERIOR STAIRS & HANDRAIL No Scale NON -SLIP BROOM FINISH VARIABLE WIDTH' MAX. CROSS SLOPE 2% 4" 3,000 PSI AIR -ENTRAINED CONCRETE COMPACTED SUBGRADE 4" TYPE 21 B STONE COVER DENOTES CONCRETE SIDEWALK PAVEMENT ON PLANS ;-- NOTE: SIDEWALKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH VDOT STANDARDS. d a . CONCRETE SIDEWALK PAVEMENT SECTION No Scale EXPANSION JOINT WITH PREMOLDED EXPANSION FILLER, "ZIP STRIP" OR EQUIV., SEAL WITH SILICONE SEALANT 1/4" SEALANT NON -SLIP BROOM FINISH WWF 6x6 W 2.9xW2.9 2" -� 4 : -T 10" 3,000 PSI AIR ENTRAINED PORTLAND CEMENT CONCRETE o 0 6" TYPE 21A STONE COVER COMPACTED SUBGRADE (CBR 11.2) DENOTES CONCRETE SERVICE AREA PAVEMENT ON PLANS d HEAVY DUTY CONCRETE SECTION No Scale 2.0" ASPHALTIC CONCRETE SURFACE COURSE - SM-9.5A 3.0" INTERMEDIATE BASE COURSE - BM25.0 TYPE 21-B AGGREGATE SUBBASE COURSE COMPACTED SUBGRADE DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PLANS HEAVY DUTY ASPHALT PAVEMENT SECTION No Scale 2.0" BITUMINOUS CONCRETE SURFACE COURSE - SM-9.5A 8" TYPE 21 B AGGREGATE BASE COURSE COMPACTED SUBGRADE DENOTES LIGHT DUTY ASPHALT PAVEMENT ON PLANS LIGHT DUTY ASPHALT PAVEMENT SECTION No Scale EXISTING PAVEMENTI PROPOSED PAVEM d SAWCUT THROUGH a U EX. SURFACE w COURSE w X w & REMOVE PAVEMENT EXISTING PAVEMENT MATCH EX. CROSS SLOPE UNLESS OTHERWISE SPECIFIED ON PLANS PROPOSED SURFACE COURSE I CR s G V4 J. ta,0' 1'. ,, K1 > Sic. Na. 0"0204b507 M E 0 M OU r-jN � c > E w a; E ~ UaLn a) 3 u. 4 3 U. o Lw 0 o- Q�UM00 WJ-Uf W > CD N C7WN� z 4- � 3: b J) C)Ln Q c U > Q . c 'n allO N (ij M -,.i' C) H • MILL EX. SURFACE COURSE SAWCUT EX. BASE COURSE EDGE OF PAVEMENT AGGR. BASE NOTE: PROPOSED PAVEMENT MUST TIE IN WITH EXISTING PAVEMENT PAVEMENT REPLACEMENT JOINT DETAIL No Scale 1.5%2" BITUMINOUS CONCRETE SURFACE COURSE - SM-9.5A 77 EXISTING AGGREGATE BASE - - /�\ COMPACTED SUBGRADE MILL AND OVERLAY SEQUENCE: REMOVE EXISTING ASPHALT. COMPACT AND ROLL TEST EXISTING BASE COURSE. THEN PLACE NEW ASPHALT SURFACE. DENOTES MILL AND OVERLAY - MILL AND OVERLAY PAVEMENT SECTION No Scale Z O � a LU p Z O Z I Z Ln Z z Q w I L Z w CK I- Q > O o O Q U-1ce cn w cn w cn w cn p Z W C W 0 W Z � W 0 W Z (x W 0 W Z U LL1 Q W Z CS Q a Q Z a Q Z ¢ Z a Q Z a W I - CL a a a � a o z chit v�i can M rn a, rn o, -4 " 11 -1 " w o 0 0 0 0 Ln n N 00 of 0 0 0 0 (ZI DATE 03-26-2018 DRAWN BY 1. SANDERS DESIGNED BY A. ALLISON CHECKED BY C. SHIFFLE77 SCALE 1 "=20' V J W LLJC: aS O U U c > 0 5' ca L 3 a) CL n W >, c t0 0 m Z 1_4 (, Q0 o c s ~' w U) z> Q c fC a� c� Q n z =_ . ^ 0 Z o v , 0 z U 3 JCL Q Uj 00 F--� w C0 �' z O M � Q z 0� a f° o c c m M rZ o O c 2 J (3 Z y z O m � a x H o o o o a� \/ a 3 ,jr > m UU N i-� aa) o s � E � M c o c � o W E E c U N 0 Ma JOB NO. y .o 40241 c N ns C y o SHEET NO. M " a� C1.00 t E 3 c c� d �0 o � a0 (D� "Z 00 og c � M o E—, -0 c c 0 @ N C a8 0 c C� z N oa i n g x I— y o m o CL 3 a 0) a) c > Y cn f0 7 �- U N C N .0 0 U @ C O to U C � C O � C U f0 O "a C f�0 �U L o C cn .O @ U O C O C y O C U m O y Q) L E H