HomeMy WebLinkAboutSUB201900198 Review Comments Preliminary Plat 2020-02-01COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832 Fax (434) 972-4126
Subdivision Plan Review
Project title:
Galaxie Farm Preliminary Subdivision Plat
Project file number:
SUB2019-00198
Plan preparer:
Shimp Engineering, Justin M. Shimp [ justinAshimp-en in�g com ]
Owner or rep.:
Jasper L or Mallie P Haynes, P.O. Box 422, Charlottesville, VA 22902
Plan received date:
31 Dec 2019
Date of comments:
1 Feb 2020
Plan Coordinator:
Tori Kanellopoulos
Reviewer:
John Anderson
SUB2019-00198
C1: Provide date of Roger W. Ray boundary survey.
Note: GIS data layers may not serve as basis of lot, road, or drainage design. Provide acceptable survey
basis of design. Preliminary plat, road plan, WPO plan, and final plat must explicitly state topographic
survey performed in support of design meets state code requirements for surveys; otherwise, Albemarle has
insufficient information (at this point) to approve any listed plan, and rejects county GIS data layers as an
acceptable basis of design. County website GIS data layers are made available as visual-downloadable data
for informational purposes only. Please note GIs Data Disclaimer, below. Please call if any questions.
Office of Geographic Data Services I GIS Data Disclaimer
GIS DATA DISCLAIMER
Albemarle County has provided these data layers for informational purposes only.
Data layers were compiled from various sources and are NOT to be construed or used as a "legal
description". Data layers are believed to be accurate, but accuracy is not guaranteed. While
Albemarle County has attempted to ensure that the information contained in these data layers is
accurate, Albemarle County expressly disclaims all warranties of any type, expressed or implied,
including but not limited to, any warranty as to the accuracy of the data, merchantability, or
fitness for a particular purpose. Albemarle County does not assume any liability for any errors,
omissions, or inaccuracies in the information provided regardless of the cause of such or for any
decision made, action taken, or action not taken by the user in reliance upon any data provided
herein.
Additional information about any given layer can be obtained by viewing the metadata contained
in the accompanying XML file. You may also wish to check out our GIS-Web application for an
interactive mapping experience where many of these layers are utilized.
Any errors, omissions, or other questions regarding any of the data layers can be reported to
Albemarle County's GIS Staff through e-mail or by calling (434) 296-5832.
Use of these data layers assumes that you understand and agree with the information
provided in this disclaimer. _
3. C1: Provide additional descriptive details for topographic survey (basis of design). Also, item 2, above.
4. Submit WPO plan at earliest convenience.
5. Submit Road Plan, to include complete drainage design, at earliest convenience.
6. With future Road Plan:
a. Provide complete drainage profiles. Include any proposed yard grate systems, for Engineering
review of potential conflicts, slope, etc.
b. Show intersection sight distance lines for internal street intersections.
Engineering Review Comments
Page 2 of 6
C2
7. Label Cow Branch.
8. Label steep slopes (preserved /managed).
(Note: Several comments anticipate Road /WPO plan design, and highlight road/WPO plan expectations, or
preliminary plat design that requires or may require revision prior to Road or WPO, or final plat approval.)
9. Note: If roof runoff is proposed to be collected and conveyed via leader lines to drop inlets or will intersect
proposed 15" DIA storm lines, show leader lines.
10. Please consider recent Building Inspections Div. guidance which may influence design of retaining walls or
affect plan approval. Albemarle County Building Official advises that: "Retaining walls shall either be
independent and terminate at the property [read, lot] line or an easement and maintenance agreement shall
be executed between property owners involved." We mention this now so that it does not cause issues, or
delay or impede subsequent plan (or building application) reviews /approvals.
C4:
11. All lots appear to be designated SF (single-family). Revise labels to reflect mix of unit types approved with
Zoning Map Amendment (ZMA) Application Plan, ZMA201800012, Galaxie Farm /Residential Areas,
sheet 7 of 10 (SFD, SFA, TH).
12. Label roads.
13. Label Lots 31, 33, 35, 37.
14. Show sight distance lines (left/right; NE/SW) at Int. Road A.1 and Route 20.
15. C4 (C6, C8): Ensure lots are located entirely outside the (100') stream buffer. Ref. ZMA Sheet 71 Note F.
Portions of Lots 62, 63, 64 are located within stream buffer.
16. C5: Provide additional preliminary design detail for transition from Road A.2 to Ex. Galaxie Farm Lane
which provides access to multiple parcels beyond proposed development. Note reading Connect Galaxie
Farm Lane to new road is insufficient for an existing road that must remain in continuous use; for example:
compare spot grade at transition to Galaxie Farm Lane at end of Road A.2 transition point (486.68') to
existing Elev. of Galaxie Farm Lane (<484'), a >2.5' vertical interval. Provide preliminary travel way
design and drainage to ensure smooth transition.
C5/C6
17. Show Class B -Type I primitive nature trail shown on ZMA Application Plan, Galaxie Farm /Circulation
(sheet 5 of 10). Show proposed trail easement (Ref. ZMA, sheet 9)
18. Label roads.
19. Revise cul-de-sacs, Roads D1 and D2 to 45' Min. Ref. VDOT Road Design Manual, Appendix B(1)-3,
Roadway Geometric Design Criteria, B. Local Roadways, 1.: "A single -unit (SU) truck design vehicle, as
defined by AASHTT, should be used for the design of all local subdivision streets. Dimensions for this
vehicle are depicted in Figure 2-2 of AASHTO Geometric Design of Highways and Streets 2011, shown in
Figure 1. Note: Fig. 1 shows path of front overhang of a single -unit (SU) truck design vehicle Min. radius
=43.5'.
Engineering Review Comments
Page 3 of 6
RDM, Appendix B(1) Fig. 1
A single -unit (SU) truck design vehicle, as defined by AASHTO, should be used for
the design of all local subdivision streets. Dimensions for this vehicle are depicted
in Figure 2-2of the AASHTO Geometric Design of Highways and Streets 2011,
shown as Figure 1.
O fm 5m
+n. a
t,� R07
Ii0 ■
FIGURE 1 — "FIGURE 2-2" SCANNED FROM "A POLICY ON GEOMETRIC
DESIGN OF HIGHWAYS AND STREETS," AASHTO, ,l
20. Provide rolltop type or CG6 to convey Road E runoff. Road E does not appear exempt from requirement to
provide curb and gutter for storm runoff conveyance (ref. 14-412.B., 14-410.G., County Engineer
(ZMA201800012) review comments, reprinted, below /item 31.)
21. Provide details, plan labels (or both) for:
a. Rolltop curb, if utilized,
b. Knox box (Road F),
c. Bollards (Road F).
22. Label distance along Route 20 to nearest street intersection (both directions).
23. Provide curb extensions for parallel parking, Road B; see design standard at VDOT RDM, B(1), pg. 59 (pg.
61 of .PDF /Link: hgps://www.virginiadot.org/business/resources/LocDes/RDM/AppendB l .pdf ).
F. Curb Extensions — Curb extensions at intersections are frequently used in
Traditional Neighborhood Developments. Curb Extensions are also used to
protect parking areas and to reduce pedestrian crossing times.
E ;
m E
H � U
� o
15' R Minimum
5l/�t10' R MWmum
25' R Minimum
EftO-e Radius
40' MlnimUm —
Curb Extension (Bulb -Out)
24. C7/C8, Grading and Utility Plan:
a. Submit calculations to support proposed 15" Max. DIA storm pipes.
Engineering Review Comments
Page 4 of 6
b. Submit conceptual SWM plan (quality /quantity); hatched outline of SWM locations is only detail
re. SWM. This is insufficient detail for preliminary plat approval. Given effect of preliminary plat
approval on subsequent plan approvals, please submit WPO Plan at earliest convenience. Also,
item 4.
c. Provide /show proposed grading for swale or similar design to collect lawn /roof runoff (south side
of Road C; Lots 8 thru 30) to prevent off -site runoff in the post -developed condition. Proposed
grade behind future building sites on these lots cannot be approved. Also, item 6.a, above.
d. Ensure adequate separation between proposed storm and sanitary sewer lines at approximate CL,
Road A.1.
e. Engineering cannot recommend preliminary plat approval of 2 X 60" HDPE w / headwall at Cow
Branch. Please provide additional design information for this crossing; design for the 25-, ram.
For perspective, please see photo d. 7/27/18 (by Albemarle), below, which shows drainage
f. ACSA Sanitary Easement may impede ability to develop Lots 29, 41, 31, 33, 35, 37, and 39, as
intended with current design.
g. ACSA Waterline Easement may impede ability to develop Lots 58-61, as shown.
h. Label roads.
i. Note existing natural drainage that clips end of Road A.2. Provide conveyance of storm runoff
that transits this natural drainage feature in the post -developed condition.
j. Avoid nuisance ponding on any private or public road; for example in circular /bulb portion of
Road B (south end Road E). Provide inlet capture and adequate conveyance at this location.
k. Provide inlets and piped drainage of runoff, Road E.
1. Engineering recommends care with design of private drive entrances to dwellings along Road E.
Storm runoff collection and conveyance applies to Road E. Also, comments elsewhere.
m. Provide /show public drainage easement at NE corner Int. Road D.2 and Road A.1 (Open Space).
n. Provide /show public drainage easements crossing Lots 29 and 61.
o. Provide storm drain inlets at low point in Road A.1.
p. Remove entirety of proposed SWM facilities from stream -ward 50' of Cow Branch stream buffer.
q. Show proposed grading, Road F; utilize 1' design contours, if necessary.
r. Provide design for Cow Branch crossing, Road F. Size pipe /culvert to pass the 25-yr event
without overtopping Road F (Emergency Access).
Engineering Review Comments
Page 5 of 6
C9
25. Provide Class B — Type I primitive trail section (Ref. ZMA, sheet 9; image below).
26. Provide additional detail for Road F: surface type /travel way type: paved, grass pavers, etc.
ZMA201800012 Sheet 7-related comments relating to SLTB201900198 /ref. sheet 7 Notes, image below
27. Note B: both 30' Access Easement and ACSA waterline (public utility) easements appear to extend 5'
within lots on west side of Road E, Lots 58-61, while 30' Access Easement intrudes 5' into Lots 62-65 on
east side of Road E. Note: No structures or improvements may occupy 20' ACSA easement, or 30' Access
easement. Please consider possible conflict at time of future building permit application. Recommend
propose no structural improvements within easements on preliminary or final plat, or Road or WPO plans.
28. Note F: Remove lots from stream buffer. Also, item 15, above.
29. Note G: Also, item 10, above.
30. Note K: Also, item 24.b.
31. Also, please consider Albemarle County Engineer's comments on ZMA201800012, 9/23/19, which appear
relevant to preliminary plat, and subsequent plan applications, reprinted as text, below:
`Waiver Requests:
(1) Double Fronted Lots: No objection.
(2) Private Streets:
- Road D: The Design Standards Manual requires private streets to meet VDOT minimum standards,
however, the County has allowed by policy the use of ASHTO Geometric Design of Very Low Local
Roads for private streets with an ADT under 400 trips per day. If Block 1 is modified to serve only multi-
family (i.e. a site plan), standards may be reduced further as shown in the Design Standards Manual.
- Road E: Must also meet low volume road standards. Identify if any additional waivers are required.
(3) Private Street Design Requirements:
- Road D: Street must meet design standards noted above, unless serving multi -family only.
- Road E: Identify the purpose of the "bulb" on this road. Parking must meet County design requirements.
Has VDOT approved spacing requirements for public road intersections?
(4) Modification of Setbacks: No objection.
The road exhibits show a corner lot in Block 1, a few lots in Block 2, and the sidewalk in Block 2 within
the stream buffer. These improvements are not exempt and cannot be located in a stream buffer. This
comment was previously made during the ZMA review, which did not (does not) show these impacts.'
ZMA sheets (for reference)
Sheet 7, Notes
v
NOTES:
A) For front loaded garages, the porch or building face shall be a minimum of 3 feet closer to the street as measured from the face of the garage door.
B) For those units that (1) do not front Roads A.2" or "B", and (2) are located in Block 2, utilizing Private Road "E" shall have a minimum front setback of 3 feet
from the right-of-way of Private Road "E" All other units shall have a minimum front setback of 5 feet, per Section 4.19 of the Zoning Ordinance.
C) All Blocks except 7 and 8 may be used for residential uses as noted by the unit types listed above.
D) All Tear yards (except those adjoining Road "E") shall have a minimum setback of 20 feet.
E) Structures along Road "E" shall have a minimum rear setback of 5 feet.
F) No structures or lots shall be permitted in the stream buffer or on preserved slopes. No preserved slopes within the development shall be disturbed.
G) As applicable, retaining walls within the development shall meet the design standards required for the disturbance of managed slopes in Section 30.7.5 of the
Zoning Ordinance.
H) Total allowable residential units shall be 65.
I) Road "C" is shown as a possible future connection to Tax Map Parcel 91-13 to be extended and dedicated upon demand of the County.
J) Road "D.1" is shown as a possible future connection to Tax Map Parcel 91-10 to be extended and dedicated upon demand of the County.
K) 25% of the required stormwater quality treatment shall be provided onsite.
Engineering Review Comments
Page 6 of 6
Sheet 8
All sections to comply with VDOT and/or Albemarle
County standards, as applicable
Sheet 9
CLASS B - TYPE 1
PRIMITIVE NATURE TRAIL -Private
EASEMENT
CLASS B - TYPE 1
PRIMITIVE NATURE TRAIL
32.
Please feel free to call if any questions.
Thank you
J. Anderson 434.296-5832 -x3069
SUB201900198 Galaxie Farm 020120 prelimplat