Loading...
HomeMy WebLinkAboutSDP202000002 Review Comments Minor Amendment 2020-02-11Phone 296-5832 COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902-4596 Site Plan review Fax Project: Keswick Hall Spa — Minor Site Plan Amendment Plan preparer: Andrew Allison, PE, Timmons Group — 608 Preston Ave, Suite 200, Charlottesville, VA 22903 [ Andrew.allison(&timmons.com] Owner or rep.: Historic Hotels of Albemarle, LLC; 701 Club Drive, Keswick, VA 22947 Plan received date: 14 Jan 2020 Date of comments: 11 Feb 2020 Reviewer: John Anderson Project Coordinator: Tori Kanellopoulos SDP2020-00002 972-4126 L3.10, Tree Planting Plan: Please show C5.1 (Grading Spot Shots Plan) storm lines as light linework (no need to show elevations, or grade) on L3.10 to evaluate for landscape conflicts. Trees should not occupy private drainage corridors, or be shown within 5' of private storm drain centerline (CL). For pipes within public drainage easements (i.e., downstream of SWM facilities), trees may not be located within public drainage easements. Understory plants should be located > 5' from CL of public drainage easements. Locating plants within a public drainage easement carries risk (plant removal /loss). Please ref. deed of dedication of public drainage easement for proscriptive language. Review areas circled in blue, below. L3.10 Zy [3: BEIULA NIGRA p1 THUJA OCCIOENIALIS 1 (�1 `ACE}RRUBRUM iI I FAGJS GFAr., I Bib *• • �t LIMIT OF WORK + 1 1 1 BEIULA NIGRA 4 PA Engineering Review Comments Page 2 of 4 ♦ram*r*rr+r+y'- ■ ■ ■ # ■ r rrrrrrrrrrr� ♦ ♦ C5.0 Please consider and respond to VSMP /WPO Amendment review comments, d. 15 Jan 2020. Note: A closer reading of 17-603.C., and definition of water -dependent facility (17-205) indicates that storm sewer is authorized in a stream buffer, meaning: 1) mitigation of stream buffer impact associated with storm pipe is not required, and 2) storm pipe may be located within the 50-streamward feet of a stream buffer. Please disregard 15 Jan 2020 Engineering plan review comment 7, which does not accurately state requirements. Engineering Review Comments Page 3 of 4 Water -dependent facility. The term "water -dependent facility" means a development that cannot exist outside of the stream buffer and must be located on the shoreline because of the intrinsic nature of its operation and which include, but are not limited to: (i) the intake and outfall structures of power plants, sewage treatment plants, water treatment plants, and storm sewers; (ii) public water -oriented recreation areas; and (iii) boat docks and ramps. 3. C6.2, LD-347: Please review inlets 118, 120, 122, 126. Check pipe dia. v. outlet water surface elevation, and revise to ensure non -pressurized flow within capacity of pipe. (Increase pipe diameter, as needed.) 4. C6.6: Show existing public drainage and SWM facility easements. Provide label ref. to deed bk.-pg., Ex. easements: 5198/669-670). Note: Submit easement plat consistent with SDP2020-00002, WPO201800078 Amendment, and plat at deed bk.-pg 5198/669-670. Note: storm lines below SWM facilities require a public drainage easement. Easement plat application: http://www.albemarle.org/unload/images/forms_center/departments/Community Development/forms/appli cations/Easement_ Plat_& Checklist.pdf 5. Provide defined storm conveyance and typ. detail for ditch /swale on east side of downslope access to Spa. 6. Recommend bypass for SWM3 should infrequent event overwhelm the underground facility, or obstruction at weir plate prevent SWM3 design discharge via storm pipe 109. A possible option: locate a relief pipe that connects SWM3 with Str. 108; image, below: Engineering Review Comments Page 4 of 4 WEIR PLATE SWM 3 4[s 180 LE 80' CMP t 5' TOP: 427.00' BOTTOM: 422.00' a PROP. 8" DIP WATERLINE Z. o N y. 0 N F� 7 O� +usv+ z aa— o,fF-zz 10� OP 3 C� HA 00% PROP 3" PVC _ & 6" DIP WATERLINES 7. C4.0: Revise 3' sidewalk to 5' width, Min. 8. C0.0: Recommend title sheet include ref. to SDP2020-00002 Please feel free to call if any questions: 434.296-5832 —x3069 Thank you SDP2020-00002 Keswick Hall Spa -Minor 021120