Loading...
HomeMy WebLinkAboutWPO201900002 VSMP SWPPP 2019-01-167 SITE DATA PLAN PREPARER: TAX MAP PARCEL No: ZONING: CURRENT USE: PROPOSED USE: PROJECT AREA: TOPOGRAPHY: GENERAL NOTE. ■ ROUDABUSH, GALE, & ASSOCIATES INC 172 SOUTH PANTOPS DR. STE A CHARLOTTESVILLE, VA. 22911 (434)-979-8121 46B 4-4 Cl-COMMERCIAL VACANT COMMERCIAL LOT OFFSITE LAY DOWN AREA FOR MATERIALS AND STOCKPILE UNTIL COMPLETION OF HOLLYMEAD DAM SPILLWAY IMPROVEMENTS (WP0201900002) 3.41 ACRES ALBEMARLE COUNTY GIS 4FT THE PURPOSE OF THIS OF THIS PLAN IS TO PROVIDE A LAY DOWN AREA WITH ADEQUATE SPACE FOR CONSTRUCTION MATERIALS AND STOCKPILING OF. EXCESS TOPSOIL GENERATED FROM THE PROJECT KNOWN AS HOLLYMEAD DAM SPILLWAY IMPROVEMENTS WPO201800039 APPROVED BY ALBEMARLE COUNTY ON 06129118. THIS AREA IS NOT TO BE USED FOR INTENTIONAL LAND DISTURBANCE AND WILL BE RESTORED TO ITS EXISTING ORIGINAL STATE UPON COMPLETION OF THE PROJECT. CONTRACTOR SHALL USE ONSITE SEEDING AS NECESSARY TO RESTORE ANY LOSS OF STABILIZATION FOR THE DURATION THIS OFFSITE PARCEL IS BEING USED AND THE HOLLYMEAD DAM SPILLWAY IMPROVEMENTS ARE DEEMED COMPLETE. (WPC:)20.1 900002) ALBEMARLE COUNTY, VI RCS I N IA VICINITY MAP SCALE; 1 "=1000 FEET SHEET INDEX SHEET 1--------- COVER SHEET SHEET 2--------- SWPPP SHEET 3--------- SWPPP NOTES & DETAILS NEW A 0 w in cn Q m z jo U � y JIVI L. TAGGART Lic. No. 22841 kid °.� 01-16-19 l il/..�SS 10 N AL IoG z w W CL O J 0 W uj 0. g �N Z Z L) 4Lu T" 0 � cm 0 0 tl) ® V iL O. C9 W o. CL LLJ J cl) o LL DATE: 1 01-16-2019 SCALE: AS SHOWN JOB: 8053 CONTOUR INTERVAL: N/A DESIGN BY: JLF SEALED BY: JLT SHEET: 01 OF O3 t 1 / / / / 1 032A0-02-00-00100 IMP i MALLOY PROPERTIES \\ LLC C/O MALLOY \ COMPANIES LLC `\\ TMP 032AO-02-00-001BO i i SOUTHERN STATES l `�\ DB 4851 PG 460 CHARLOTTESVILLE / COOPERATIVE INC ! DB 1961 PG 246 p (Sr'4TERp ROAD / / t / �� _ GHT_OF wA Y �\ / ,`C` i /----------- / / ! °� NOTE: t / �O AREA SHOWN WITHIN SILT FENCE IS 1 ACRE. TMPI a MIN U.0_ \ THIS SITE SHALL ONLY BE USED AS A MATERIAL I r + 04684-00-00-004 a AYDOWN AREA AND A TEMPORARY STOCKPILE 0�5 L / E CESS TOPSOIL GENERATED FROM IA-ZAN LIMITED r VIA FX WP0201800039. SEE STOCKPILE AGREEMENT ON I r 9- SHEET 4 OF 4 FOR ADDITIONAL DETAILS. PARTN~� DB TMP 03200-00-00-037CO t l r r \ r WGN PROFFITT LLC C/O WALGREEN CO REAL ESTATE t l l 1 O SF TAX DEP DB 3790 PG 692 tt l i tl t t / r STAGING AREA CE TS r r r /,��-PS �SQ�? // / / '! TMP 03200-00-00-037C1 ��i /''// /''�' DC MERCER, MARY R & GEORGE R MERCER SR / 5 G�' l tNN TR, / I / P�' QP • / ; AGE / ! n / r r ~ � /''/ /, \ �~• ~., '�yt�' '''''' STOCKPILE \ ,� { .' AREA / 3, /NIIN / / + ____ __ __ "I // ; % ____ -----__ SILT FENCE SHALL It / / �' j - ----- A PROPERTY LINE / ! - - -� ,••3 z�6,___ � \ \�.. / r,' i /-_____--- SF APPROX. 10' FROM THE EDGE OF PAVEMENT AND/OR PROP N l TMP 046B4-00-00-00300 JA-ZAN LIMITED PARTNERSHIP DB 1169 PG 347 NOTE NOT ALL SWPPP MEASURES SHOWN HEREON MAY BE REQUIRED FOR THE PROJECT AND LOCATION OF MEASURES MAY VARY DEPENDING ON SITE CONDITIONS. THIS PLAN IS FOR ILLUSTRATIVE PURPOSES AND SHALL BE MAINTAINED BY THE CONTRACTOR AS NECESSARY. THIS PLAN SHALL BE AN EXTENSION OF THE EXISTING SWPPP FOR HOLLYMEAD DAM SPILLWAY IMPROVEMENTS WPO201800039. MP 046B4-00-00-00500 -TCHEL, ROBERT G OR KATHLEEN 0 DB 1685 PG 014 / I WASH RACK ("WR") SHALL BE INSTALLED IN TMP 03200-00-00-036G0 ACCORDANCE WITH THE CONSTRUCTION ENTRANCE AND LIGHTHOUSE WORSHIP SLOPE TO A TEMPORARY DRAIN PIT AS DEEMED CENTER INC NECESSARY BY ALBEMARLE COUNTY EROSION INSPECTOR DB 2664 PG 033 WATER TANK WITH (2) POWI WASHERS SHALL BE STORED 0 AT THE CONSTRUCTION ENTRA r' 1 / 1 t TMP 032 LIGHTHC CE DB I ! r / / / \ / / / 1 t t SCALE 1 "=50' 50 0 50 100 SCALE IN FEET I U a 0 O U "W = T cn Nm N Q Z� QzZ) O � z (5 V o Q^ >O O OU JWZ C4 ® Q� cn wWw ro o J 0 Q J � N O 2 v c°'v co Lu -j 0 LL co 0 ] wi C cccr, C)o0 aLu 1—z9 W��� Z � CO T W Z ®W 0 � G O F U W W Q W m Z �.LTH OF Dry' o G' JIMMY- L. TAGGART Lic. No. 22841 �v4 01-16-19 �s`�I ONAL z,_ DATE: 1 01-16-2019 SCALE: AS SHOWN JOB: 8053 _ CONTOUR INTERVAL:4 FT DESIGN BY: I JLF SEALED BY: JJLT SHEET: 02 OF 03 ®� PURPOSE 4VAC50-60-54 of the Virginia Stormwater Management Program (VSMP) Permit Regulations requires that Stormwater Pollution Prevention Plan (SWPPP) be developed for all regulated land disturbing activities, The SWPPP must include, but not be limited to, an approved erosion and sediment control plan, an approved stormwater management plan, and this Pollution Prevention Plan (PPP) for regulated land disturbing activities, and a description of any additional control measures necessary to address a TMDL as applicable. The plan for implementing pollution prevention measures during construction activities developed on this sheet must be implemented and updated as necessary. Any PPP requirements not included on this sheet must be incorporated into the SWPPP required by 4VAC50-60-54 that must be developed before Land disturbance commences. This PPP identifies potential sources of pollutants that may reasonable be expected to affect the quality stormwater discharges from the construction site (both on- and off -site activities) and describes control measures that will be used to minimize pollutants in stormwater discharges from the construction site. OTHER REFERENCED PLANS SWPPP requirements may be fulfilled by incorporating, by reference, other plans. All plans incorporated by reference become enforceable under the VSMP Permit Regulations and General Permit VAR10 for Discharges of Stormwater from Construction Activities. If a plan incorporated by reference does not contain all of the . required elements of the PPP, the operator must develop the missing elements and include them in the SWPPP. POTENTIAL POLLUTANT SOURCES The following sources of potential pollutants must be addressed in the Pollution Prevention Plan. Various controls and/or measures designed to prevent and/or minimize pollutants in stormwater discharges from the project site must be applied to the sources found on the site. Additional information concerning the following controls and/or measures may be found in the SWPPP. Deviations from the location criteria may be approved by the Albemarle County Inspector. LEAKS, SPILLS, AND OTHER RELEASES ✓ The operator(s) shall ensure procedures are in place to prevent and respond to all leaks, spills and other releases of pollutants. ✓ The operator(s) shall ensure all leaks, spills and other releases of pollutant are contained and cleaned immediately upon discovery. Any contaminated materials are to be disposed in accordance with federal, state, and/or local requirements. ✓ The operator(s) shall ensure spill containment kits containing appropriate materials (e.g., absorbent material and pads, brooms, gloves sand etc.) are available at appropriate locations, including, but not limited to: designated areas for vehicle and equipment maintenance; vehicle and equipment fueling; storage and disposal of � o hazardous and stora ge and disposal f h ' s products, .and waste; construction materials, pr ug p and toxic materials; and sanitary waste facilities. ✓ The locations of the spill containment kits are identified as described below: Shown on Date Plan Sheet Location #(S) Approved Plan REVISIONS TO LOCATIONS Shown on IOperator(s) Date Plan Sheet Location Initials #(S) ✓ The operator(s) shall notify the Department of Environmental Quality of leaks, spills, and other releases that discharge to or have the potential to discharge to surface waters immediately upon discovery of the discharge but in no case later than 24 after the discovery. ✓ The operator(s) shall notify the Department of Environmental Quality (DEQ) of leaks, spills, and other releases that discharge to or have the potential to discharge to surface waters immediately upon discovery of the discharge but in no case later than 24 after the discovery. Written notice of the discharge must be sent to DEQ and Henrico County Department of Public Works within five (5) days of the discovery. Virginia Department of Environmental Albemarle County Quality Community Development NEED ADDRESS Engineering Department (804) 786-3998 (phone) 401 McIntire Road (804) 786-1798 (fax) Charlottesville, VA 22901 (800) 468-8892 (outside normal working (434) 296-5832 hours) EQUIPMENT / VEHICLE WASHING ✓ Washing must be conducted in a dedicated area that is located to maximize the distance from storm drain inlets, ditches, waterbodies or wetlands but no less than 50 feet from those features. ✓ All wash water used in vehicle wheel washing must be directed to a sediment basin/trap. ✓ All vehicle washing activities other than wheel washing must have secondary containment. ✓ Each facility must have appropriate signage to inform users whe re the de dicated area(s) are located. VEHICLE FUELING AND MAINTENANCE ✓ Conduct regular maintenance in a dedicated area that is located to maximize the distance from storm drain inlets, ditches, waterbodies or wetlands but no less than STAPLES 50 feet from those features. (2 PER BALE) ✓ If fueling is conducted at a dedicated area, the location must be located to WOOD OR METAL STAKES (2 PER BATE) maximize the distance from storm drain inlets ditche s, waterbodies or wetlands but no less than 50 feet from those features. ✓ The dedicated areas must be designed to eliminate the discharge of spilled and leaked fuels and chemicals from vehicle fueling and maintenance activities by AND FLAGGING DISCHARGES OF SOAPS, DETERGENTS, SOLVENTS, AND 3 SIDES WASH WATER FROM CONSTRUCTION ACTIVITIES SUCH AS CLEANUP OF STUCCO, PAINT, FORM RELEASE OILS, AND CURING COMPOUNDS ✓ Washing activities associated with construction activities other than vehicle and equipment washing, such as clean up of stucco, paint, form release oils, and curing compounds are to be conducted in a dedicated area. LATH AND FLAGGING SANDBAG (TY'•) ✓ The dedicated area must be located to maximize the distance from storm drain providing secondary containment (spill berms, decks, spill containment pallets, 10' MIN. ON 3 SIDES VARIES —► inlets, ditches, waterbodies or wetlands but no less than 50 feet from those features. providing cover where appropriate, and having spill kits readily available). —STAKE Separations of less than 50 feet may be approved by the Environmental Inspector. ✓ Each facility must have appropriate signage to inform users where the dedicated _ o o C� TOP OF BERM ✓The dedicated areas must be designed to prevent the discharge of soaps, c area(s) are located. I^ A' TEI I detergents, solvents, and wash water. VARIES - 10' MIN. 1 U. o 0 IE 0 0 0 0 0 10 MIL PLASTIC LINING ELM STRAW BALE (TYP•) 10 MIL PLASTIC LINING OTTOM OF BERM NOT TO SCALE ELM NOT TO SCN.E CONCRETE WASHOUT AREA CONCRETE WASHOUT AREA ABOVE -GRADE CONTAINMENT AREA Wf STRAW BALES BELOW -GRADE CONTAINMENT AREA a'" / PRESSURIZED WATER o� SOURCE (CONTINGENT UPON PROVIDE DRAINAGE AWAY / WATER MAIN INSTALLATION) i ~ FROM TO A THE WASH RACK �OQ�/ I / e DEVICE�-TRAPPING 1. / \_ / KEEP A BROOM AND SHOVEL' , T CLOSE TO THE RACK TO CLEAN THE STREET. - A / WASH RACK IT IS ADVISABLE TO PROVIDE A SEPARATE ENTRANCE TO LIMB A . J� TRAFFIC ACROSS THE RACK AND REDUCE WEAR AND MAINTENANCE. ��� **THE FOLLOWING IS AN EXAMPLE OF AN ACCEPTABLE WASH RACK. OTHER APPROVED METHODS MAY BE UTILIZED.' ONE SECTION OF REINFORCED CONCRETE CATTLEGUARD 3' WASHED STONE UNDER do BETWEEN THE LOCATION MUST SLOPE AWAY SLATS TO DRAIN WATER AND SEDIM FROM THE STREET OR STEPS MUST AW Y O. E CK BE TAKEN (GRADING, DIVERSIONS, ETC.) TO PREVENT RUNOFF FLOWING Shown on Date Plan Location of Dedicated Area(s) Sheet # s Approved Plan Shown on Date Plan Sheet #(s) REVISIONS TO LOCATIONS Location of Dedicated Area(s) Operator's Initials ✓ If mobile fueling will be used, the fueling must be done in an area that located to maximize the distance from storm drain inlets, ditches, waterbodies or wetlands but no less than 50 feet from those features. ✓ Spill kits must be readily available at all mobile fueling locations. ✓ On -site storage tanks must have a means of secondary containment (spill berms, decks, spill containment pallets, etc.) and must be covered where appropriate. ✓ All vehicles on site must be monitored for leaks and receive regular preventive maintenance to reduce the chance of leakage. MIL PLASTIC LINING IVE MATERIAL (OPT.) BALE (TYP.) G WIRE 10 MIL PLASTIC 11 SECTION A -A' NQT ro SCALE INTO. THE STREET. FOUNDATION OF B� _. , ,, �. ^ DISCHARGE FROM STORAGE, HANDLING, AND DISPOSAL ' OF CONSTRUCTION PRODUCTS, MATERIALS, AND WASTE COMPACTED cRuRUN STONE s r r SILT FENCE ceorExnLE sFcnoN 'A —A • LOCATE ON FABRIC DOWNHILL SIDE ✓ Storage of construction products, materials, and waste is to be conducted in WASH RACK OF PORTABLE dedicated areas. SEDIMENT CONTAINMENT AREA ET ✓ The dedicated area must be located to maximize the distance from storm drain inlets, ditches, waterbodies or wetlands but no less than 50 feet from those features. Separations of less than 50 feet may be approved by the Environmental Inspector. SOLID WASTE COLLECTION CONTAINMENT AREA j ✓ The dedicated areas must be designed to minimize the discharge of pollutants from SILT FENCE I NOT TO SME storage, handling, and disposal of construction products, materials and wastes LOCATE ON including (i) building products such as asphalt sealants, copper flashing, roofing COLLECCTIIO14 AREA materials, adhesives, concrete admixtures; (ii) pesticides, herbicides, insecticides, fertilizers, and landscape materials; and.(iii) construction and domestic wastes such as packaging materials scrap construction materials mason products, timber, ONTROL TRACKING p g g p masonry p ' (GRAVEL, PAVEMENT OR pipe and electrical cuttings, plastics, Styrofoam, concrete and other trash or building OTHER STABLE SURFACE) OUMPSTER OR SOLID products.. WASTE CONTAINER ✓ Each facility must have appropriate signage to inform users where the dedicated area(s) are located. Shown on Locations) of Dedicated Area(s) for storage of construction Date P Ian Sheet products and materials #s Approved Ian P .. REVISIONS TO LOCATIONS Shown on Location(s) of Dedicated Area(s) for storage Operator(s) Date Plan Sheet #(s) of construction products and materials Initials Shown on Location(s) of Dedicated Area(s) for waste from Date Plan Sheet construction products a� ...... ­+­nd materials #S . � - ...... ­­­­..'1,+1.+­­­+1 ..... --........--- Approved Plan _. . REVISIONS TO LOCATIONS Shown on Location(s) of Dedicated Area(s) for waste Operator(s) Date Plan Sheet from construction products and materials Initials #(S) ✓ Follow all federal, state, and local requirements that apply to the use, handling and disposal of pesticides, herbicides, and fertilizers. ✓ Keep chemicals on site in small quantities and in closed, well marked containers. ✓Clean up solid waste including building ildingmat materials, garbage, e, and on a dail y Y basis and deposit into covered dumpsters that are periodically emptied. ✓ Schedule waste collection to prevent exceeding the capacity of onsite containers. Additional containers may be necessary depending on the phase of construction (e.g., demolition, etc.) ✓ Dispose of all solid waste at an authorized disposal site. ✓ Ensure that containers have lids or are otherwise protected from exposure to precipitation. DISCHARGES FROM OTHER_ POTENTIAL POLLUTANT SOURCES . ✓ Discharges from other pollutant sources (e.g., water line flushing, storm sewer flushing, above ground storage tanks, etc.) not mentioned elsewhere must be addressed. Other Potential Pollutant Sources Locations of Potential Pollutant Sources 4 =, sx rx' .£ i E i %,w £ fS l f:. £` 3. E. P; �, F # % tux 5 5 t E r r a,, t �. f S x c �,,,,, �I E> t;; 1 R3 0 � € , €' § i x xd' d s s L9 y E i `, F Y � Nr �, dp E € p "� d I 3 £ § +t �l4?" t EEa frr 1t _: 7 E lE 9YE. 3 �£L` '. �' `�N iY ES � _ E` E{!! 3 a I E d%SA. S .I� x .n1— k -: f. y F ,n,Ei L bi L E ,L 5'�Si�'kr' E y ''''L , - 3 EIE {v1 5-"o'J� 'LLn �€i" J eta _ k< Fri is '?�• v r , :,, .its +Ya , _ �.., ,fit ig ��,; # ,, s ^x� sn 9 x �4 r g f E4 .# r E,`.. a ..,, rf Kc I € �x `:„ .,ut £ S # y aF' d `` 0 ! h ( _ hd dxf`-Fxf% E P,p Y x If � £ 'E€ y P i` ,�£'€ rE`� 3 ,+:, S E . R} f r g I R E. FEE �(f 3"� �VtI k. ":€ ' �E'^"', ,,M 1, i'. ' v, LfaYdi }11 E� � t 0 L"' s IK "` fi "r . iz r x v'k $ r i Fi' 2'" i G `a`' R �'kEs* i-�,..kR' L'f `3�d x F Y^ 5 a ....aa ,j :., t ` a1k ai.�€ h 11:. ,�kE '#i� NL ,�Ei 3. �' L S` .a� kq �.W e'z, '' r' , M E e,, n"kL., ..L. ....£ T t4 ,SE,`1 ,r ., rk»`:' .S ...::.Zs E _.:,., t "��R`:� i."A4y ., 93 �,,AAk�,o, d ,.. ,.F ✓ Above ground oil storage tanks with a storage capacity exceeding 1,320 gallons and have a reasonable expectation of a discharge into or upon Waters of the United States are required to have a Spill Prevention Control and Countermeasure (SPCC) Plan. ✓ The discharge of contaminated flush water and material removed during flushing operations must be collected and disposed of in accordance with appropriate federal, state, and local requirements. FUELING AREA BELOW —GRADE CONTAINMENT AREA 10 MIL. PLASTIC 3' REA SECTION A -A' 12' HIGH DIVERSION BERM NOT o SCALE 10' STD. PORTABLE TOILET ON 3 DOWNHILL SIDES VARIES SANDBAG (TYP.) , aM Tg U :... :., PAVED FUELING AREA r ", VARIES t .:�. .. 10 MIL. PLASTIC LINING BOTTOM OF BERM TOP OF BERM DISCHARGES FROM CONCRETE RELATED WASH ACTIVITIES ✓ Concrete trucks are not allowed to wash out or discharge surplus concrete or drum wash water on site except in a dedicated area(s) that is located to prevent discharge to storm drain inlets, ditches, waterbodies or wetlands but no less than 50 feet from those features. ✓ Each facility must have a stabilized access to prevent mud tracking into the street. ✓ Each facility must have appropriate signage to inform users where the dedicated area(s) are located. ✓ Facilities must be cleaned, facilities sco constructed, once the washout area is s two-thirds (2/3) full. Shown on Date Plan Location(s) of Dedicated Area(s) Sheet # s Approved Plan . PI n . Shown on Date Plan Sheet #(sl REVISIONS TO LOCATIONS Location(s) of Dedicated Area(s) Operator(s) Initials ✓ The dedicated area must be covered (e.g., plastic sheeting, temporary roof, etc.) to prevent contact with stormwater. ✓ The contaminated wastewater from the dedicated area must be collected for disposal by a waste hauler or discharged to the sanitary sewer. ✓ In situations where these pollutants are or could be generated at locations other than at the designated area (e.g., concrete pours, building washing, etc.), cover (e.g., plastic sheeting, temporary roof, etc.) must be provided to prevent contact with stormwater and the contaminated wastewater from the activity must be collected for disposal by a waste hauler or discharged to the sanitary sewer. DISCHARGES OF HAZARDOUS, TOXIC AND SANITARY WASTE ✓ Storage and disposal of hazardous, toxic and sanitary wastes are to be conducted in dedicated areas. . ✓ The dedicated areas must be located to maximize the distance from storm drain inlets, ditches, waterbodies or wetlands but no less than 50 feet from those features. Separations of less than 50 feet may be approved by the Environmental Inspector. The dedicated areas must be designed to prevent the discharge of hazardous, toxic and sanitary waste by avoiding contact with precipitation ✓ Each facility must have appropriate signage to inform users where the dedicated area(s) are located. Shown on Location(s) of Dedicated Area(s) for storage and disposal of Date Plan hazardous and toxic wastes Sheet # s Approved Plan 'i: P n l REVISIONS TO LOCATIONS Shown on DatePlan Location(s) of Dedicated Area(s) for storage Operator(s) a Sheet #(s) and disposal of hazardous and toxic wastes Initials Shown on 11 Date Plan Location(s) of Dedicated Area(s) for portable toilets Sheet #(s Approved Plan ` REVISIONS TO LOCATIONS Shown on Location(s) of Dedicated Area(s) for portable Operator(s) . Date Plan toilets Initials Sheet #(s) ✓ Consult with local waste management authorities or private firms about the requirements for disposing of hazardous materials and/or soils that may be contaminated with hazardous materials. Never remove the original product label from the container. Follow the manufacturer's recommended method of disposal. ✓ Schedule periodic pumping of portable toilets and dispose of waste ✓ Dispose of all solid waste at an authorized disposal site. SWPPP MODIFICATIONS AND REVISIONS The operator(s) shall ensure the SWPPP is modified and/or revised to reflect: ✓ Changes in qualified personnel; delegated authorities or other personnel required as a condition of the General Construction Permit; ✓ Changes in site conditions; ✓ Changes in the design, construction, operation, or maintenance of the construction site that affect the potential for discharges of pollutants that are not addressed in the normal implementation of the plan; and ✓ Ineffective control measures identified during inspections or investigations conducted by the operator's qualified personnel or local, state or federal officials. Modifications/revisions to the SWPPP shall include additional or modified control measures to address the identified deficiencies. If the necessary modifications/revisions require approval by the Administrator or DEQ, the modifications/revisions must be implemented no later than seven (7) calendar days following approval. II wing pp If the necessary modifications/revisions do not require approval by the Administrator, the modifications/revisions must be implemented prior to the next anticipated storm event or as soon as practicable. SWPPP UPDATES The operator(s) shall update the SWPPP to include: ✓ A record of dates when 1) major grading activities occur, 2) construction activities temporarily or permanently cease on a portion of the site, and 3) stabilization measures are initiated; ✓ Documentation of modifications and revisions to the SWPPP; ✓ Areas that have reached final stabilization where no further SWPPP or inspection requirements apply; ✓ All properties that are no longer under the legal control of the operator and the dates Ton which the operator no longer had legal control over each property; and ✓ The date, volume, and corrective/preventative actions implemented for any prohibited discharge. . The operator(s) shall update the SWPPP no later than seven (7) days following any of the situations identified above. OPERATOR IN SPECTIONS The operator(s) identified below shall provide for inspections of the permitted Ind- disturbing activities by the qualified personnel identified below. The inspections will be conducted (select one the following options): Where areas are in a stabilized condition or runoff is unlikely due to winter conditions, the inspection frequency may be reduced to once every 30 days while these conditions exist. Otherwise, the operator(s) shall resume the regular inspection frequency identified above. The operator(s) shall provide for inspections of the permitted land -disturbing activity to ensure implementation and continued maintenance of all requirements of the Stormwater Pollution Prevention Plan (Erosion and Sediment Control Plan, Stormwater Management Plan, Pollution Prevention Plan, TMDL requirements, etc.). Records of the required inspections must be maintained and included in the SWPPP binder. The qualified personnel are encouraged to use the Operator Inspection form provided in the SWPPP binder to document the required inspections. If inspections are conducted once every five (5) business days and no later than 48 hours following any measureable storm event, the location of the rain gauge used to determine the amount of rain must be included in the SWPPP and documented in the inspection report. ACKNOWLEDGEMENTS I certify under penalty of law that the qualified personnel identified below: a. has been designated by the Operator to conduct inspections of the permitted site; b. is knowledgeable in the principles and practices of erosion and sediment control and stormwater management; C. possesses the skills to assess conditions at the permitted site for the Operator(s) that could impact stormwater quality and quantity; 'd. will assess the effectiveness of any erosion and sediment control measures or stormwater management facilities selected to control the stormwater discharges from the permitted site; and e. will conduct inspections in accordance with the frequency noted above in the OPERATOR INSPECTIONS section of this sheet. QUALIFIED PERSONNEL . i fE�.. 3 3s�i "E "'"". x �r. .�,�.€`E_ t of 5e,�f Name (print) w F"111-1-1 L s tE t e xnE�= <.fi-x"rsss t* ,,E'�1�:,i ,:f .�� "3k E�, x d `� Y a E ,yrf a2f t ''a II s E 1i f " L €i x: ., ,h xf ,,.,,�,...t �{ t"x [ t -f t�F k r a. ,. ,.., A6 �,s�; ,a....v_.; r. ,� .. u .�. .0 E9, .._..., .:R z.,. o.. «... .. H. i R": I N D f 4 % h Phone t.,". 11n,,.,... hL __ fE N,1 , _. . l. ,...._._ I 10 �.. . �£ €L �� Y 1 s �,KiS`c zE $$ 1f a�`'f'„'x �Yf ,�r F'�s�f - £ s3"d t Additional information is located in Tab 6 of the SWPPP Binder. As the Operator(s) or Delegated Authority, I understand that prior to initiating an disturbance, the potential pollutant sources, appropriate control measures, and all responsible parties (operator, qualified inspection personnel, contractors, etc.) required I s a condition of the General Construction Permit (GCP) and the Stormwater Pollution Prevention Plan (SWPPP) must be identified. I also understand this information must be updated as necessary throughout all phases of construction until the GCP is terminated. Furthermore, I/we certify under penalty of law that I/we have read and understand all requirements of the SWPPP (erosion and sediment control plan, stormwater management plan, pollution prevention plan, TMDL provisions, administrative requirements, etc.) and GCP and that the information herein is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine or imprisonment for knowing violations. I/we understand that I/we are ultimately responsible for compliance with all conditions and requirements of the SWPPP and GCP and for ensuring all contractors and subcontractors on the permitted site are aware of the conditions and requirements of the SWPPP and GCP. I/we shall comply with all conditions and requirements of the SWPPP and shall at all times properly operate and maintain all measures and control (and related appurtenances) which are installed or used to achieve compliance with the conditions of the GCP. Proper opration and maintenance also includes adequate funding and adequate staffing. I/we shall take all reasonable steps to minimize or prevent any discharge in violation of the SWPPP and/or GCP. I/we understand that if it determined by the Department of Environmental Quality (DEQ) in consultation with the State Water Control Board at any time that stormwater discharges are causing, have reasonable potential to cause, or contribute to and excursion above any applicable water quality standard, the DEQ may, in consultation with the Administrator, take appropriate enforcement action and require: a. Modification of control measures to adequately address water quality concerns; b. Submission of valid and verifiable data and information that are representative of ambient conditions and indicate that the receiving water is attaining water quality standards; or C. Cessation of discharges of pollutants from construction activity and submit an individual permit application according to 4VAC25-870-410. OPERATOR(S) / DELEGATED AUTHORITY r' Si ature Date Name (r, Int) an Additional contact information can be found in the SWPPP Binder. r U 0 4 t- 0 <�* U 01. W,- _ En I NN m NQ ZN2Z)(0Q OW Z-0 U' q>>O �W u® L-iz OU �_1 0.Z �-0Q>Q ()()(0�w U Q OI d8 co 0Cc N CC Q? 2 �=rnO20UU CO ,00Cc I � QN 0U)� CC (5Cc��Z W2 0❑LLco LU M () ] ij a LO rs C _N��U t 4W I"' z o ILIA 2 �ItcO a) �,— WzOtu =a g4�a-0 9 8 III O /I IIII I. U ` ' 1 JIMMY' L. TAGGART Lic. No. A 22841 p0401-16-19 % �*SIONAL S't Z :5 W 2 0 tn W J O ... J Q IIm CL g W .. CO it 0 > 06 � U j Z Vn o U � s cv F"' CL®Z�® �I W w a ® � Q. 2 W a. W 3: LL J LL O O DATE: 1 01-16-2019 SCALE: I AS SHOWN JOB: 8053 CONTOUR INTERVAL: N/A DESIGN BY: I JLF SEALED BY: IJLT SHEET: 03 OF 03