Loading...
HomeMy WebLinkAboutARB201900095 Checklist 2019-08-29 SIGN REVIEW CHECKLIST with REFERENCES—Wall Sign, Single Business ARB 2019-95, Dogotopia, Wall Sign 08-29-2019 REF CHECKLIST ITEM NOTES TYPE X 9.b For internally illuminated signs, channel lettering OK (mounted on a raceway or individual letters) is preferred to cabinet signs. X 5.b When channel letters cannot be adequately accommodated, None proposed internally illuminated cabinet signs may be considered. X 6 Reader boards are discouraged. None proposed MATERIALS X 4.c Materials used in the sign should complement the building OK being served by the sign. COLOR X 4.e Color for raceway-mounted channel letters, the raceway OK—noted on drawing shall match the wall color. X Sign colors must be harmonious with each other. OK Sign colors must not clash with the site, when viewed in OK daylight and at night. Overly intense color, (such as dayglo or fluorescent None proposed colors), areprohibited. Use of three colors or less (black and white considered as OK colors) Additional colors may be approved if they contribute to the sign balance/unity. SIZE, SCALE, PROPORTION,AND LOCATION X 4.b Signs may not exceed the size, height and setback OK—Per Jeff Baker requirements as outlined in Section 4.15 of the Albemarle Ref: B2019-01861 for other wall signs County Zoning Ordinance (unless sign has a variance). 8/15/19- revised recv'd: proposed (all 5 wall signs) = 122.3 1 REF CHECKLIST ITEM NOTES sq.ft double-frontage= 160' max size allowed (80' x 1.5= 120+80'x 0.5 =40)= 160 sq. ft/proposed = 163 sq.ft Ref: B2019-01955 for Monument refacing X Appendix A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall OK A.A area is a good working proportioning system for placing a sign. X Appendix Color, form, surface pattern, shape, and disposition of OK A.A.4 elements and openings in an architectural design can affect our perception of scale and can impact the appearance of a sign on a building. X 9.d The wall sign's size must coordinate with the architectural OK—shown in approved sign band element's size. The sign should not over-crowd the architectural element, OK the wall, or the sign area. Buildings and building elements should not be used as OK billboards. X 9.a Wall signs must integrate with the building's architecture. OK—shown in approved sign band The sign placement should not obscure architectural OK features or details, (such as cornices, windows, columns, pilasters and paneling). X 9.d An appropriate height for channel letters in a 30" high sign N/A band is 18". This allows 6" of unoccupied space above and below the N/A letters. 2 REF CHECKLIST ITEM NOTES 4" of clear space above, below, and to the sides of a N/A channel letter sign is considered a minimum, with larger clearances required for larger sign bands. Degree of visibility, the distance from the Entrance OK Corridor, and the architectural design of the building/area will determine sign size, placement, and proportions. X 4.d Lettering should be in proportion (font size and typeface OK style) to the sign and the building. Use of three typefaces or less. OK— 1 Additional typefaces may be approved if they contribute to N/A a balanced/legible/unified sign design. X 9.e.iv The width of the outline must be in proportion to the width None proposed of the letter. An outline width of 1/8" has been found to be an None proposed appropriate sign dimension. TRADEMARKS, CORPORATE LOGOS AND GRAPHICS X 4.f The ARB may require that the color and scale of standard OK—well integrated templates for trademarks, service marks, corporate logos and graphics be modified. When used,trademarks, service marks, corporate logos OK and/or graphics should be incorporated as an integral part of the overall sign. X 5.a External (or no) illumination is preferred for approved OK—internal graphics/logos; X 5.b internal illumination may be considered for approval on a OK case-by-case basis. LIGHTING X 9.e.i External (or no) illumination is preferred for wall signs. OK—internally lit channel letter X 5.f Any internal illumination is considered to contribute to OK 3 REF CHECKLIST ITEM NOTES visual clutter and will be limited. X S.c Internal illumination design approval will be evaluated on None proposed size, balance, complexity, and distance from the Entrance Corridor. X 9.e.iv The backgrounds of such cabinet signs must be made This is not noted on the drawing. opaque (zero light transmission). X 5.e External illumination should be shielded and not create None proposed glare. All external light sources shall be white. None proposed X 9.ii Sign lighting (external) should be shielded so that it None proposed illuminates only face of the sign and does not shine beyond the edge of the sign. X 9.iii Channel letters with translucent faces must have no light OK spilling outward from the top, bottom, sides or back. Faces and returns of channel letters shall be opaque when None proposed back-lit(halo-lit). X 9.iv Cabinet signs shall have a non-illuminated background, or This is not noted on drawing. an opaque (zero light transmission) background. Cabinet signs shall be constructed such that no light spills OK outward from the top, bottom, sides or back. X 5.g All illumination shall be non-blinking. None proposed. X 5.h An exposed light source that forms the body of a sign, None proposed (such as exposed neon signs), shall not be used in the Entrance Corridors. ARB ACTIONS ❑ Deleted If r ED lighting ee the r drawing m ,st state following The level of illumination provided by the LED lights will 6/3/19 ARB 30 milliamp (ma) neon. action 4 REF CHECKLIST ITEM NOTES X Action on ARB-P Red acrylic #2283 has been determined to be an None proposed (BP)2001-12 inappropriate color for signs. Pantone color match Wood Grill for 2283 is 485C. Red#2793 has been approved as an acceptable substitute. Pantone color match for 2793 is 187C. (See below.) X 12/21/15 action on Generally, for signs in the Entrance Corridors, red 485 None proposed ARB 2015-114 & - may be acceptable on a case-by-case basis as a 115 Shell Signs secondary color. X ARB Visual clutter resulting from adjacency, for example at the None proposed Action Hardee's locations, is a reasonable basis for not allowing Memo: illumination of the graphic. 5/7/12 X ARB Accent color letters can be used in a sign when portrayed None proposed Action as a graphic, up to 33% of the length of the sign. Memo: 8/3/2015 5