HomeMy WebLinkAboutARB201900132 Checklist 2019-12-10M
E
L
E
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
Updated: 6-17-2016
REF
CHECKLIST ITEM
NOTES
TYPE
❑
.b
For internally illuminated signs, channel lettering
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
S.b
When channel letters cannot be adequately accommodated,
internally illuminated cabinet signs may be considered.
t
❑
6
Reader boards are discouraged.
MATERIALS
4.c
Materials used in the sign should complement the building
being served by the sign.
01 • t L i
COLOR
❑
4.e
Color for raceway -mounted channel letters, the raceway
Nf
shall match the wall color.
Sign colors must be harmonious with each other.
Sign colors must not clash with the site, when viewed in
tp5 J" Gee, t,
daylight and at night.
t�
Overly intense color, (such as dayglo or fluorescent
colors), are prohibited.�
v-(
Use of three colors or less (black and white considered as
colors)
Additional colors may be approved if they contribute to the
sign balance/unity.
SIZE, SCALE, PROPORTION, AND LOCATION
❑
4.b
Signs may not exceed the size, height and setback
requirements as outlined in Section 4.15 of the Albemarle
County Zoning Ordinance unless sign has a variance .
C
REF
CHECKLIST ITEM
NOTES
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
,t S;S r ,
�''
A.A
area is a good working proportioning system for placing a'
sign.
Appendix
Color, form, surface pattern, shape, and disposition of
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
❑
9.d
The wall sign's size must coordinate with the architectural
element's size.
The sign should not over -crowd the architectural element,
the wall, or the sign area.
Buildings and building elements should not be used as
billboards.
❑
9.a
Wall signs must integrate with the building's architecture.
The sign placement should not obscure architectural
features or details, (such as cornices, windows, columns,'�
i �S is �,sw
pilasters and paneling).
❑
9.d
An appropriate height for channel letters in a 30" high sign
band is 18".
This allows 6" of unoccupied space above and below the
letters.
i
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building/area
will determine sign size, placement, and proportions.
REF
CHECKLIST ITEM
NOTES
D
4.d
Lettering should be in proportion (font size and typeface
e
style) to the sign and the building.
Use of three typefaces or less.
1
Additional typefaces may be approved if they contribute to
i
a balanced/legible/unified sign design.
❑
9.e.iv
The width of the outline must be in proportion to the width
of the letter.
An outline width of 1/8" has been found to be an
}
appropriate sign dimension.
A
l v A--
RADEMARKS, CORPORATE LOGOS AND GRAPHICS
4.f
The ARB may require that the color and scale of standard
templates for trademarks, service marks, corporate logos
�� A —
and graphics be modified.
When used, trademarks, service marks, corporate logos
and/or graphics should be incorporated as an integral part
of the overall sign.
S u
External (or no) illumination is preferred for approved
ra hics/lo os;
5.b
internal illumination may be considered for approval on a
case -by -case basis.
LIGHTING
❑
9.e.i
External or no illumination is preferred for wall signs.
S.f
Any internal illumination is considered to contribute to
visual clutter and will be limited.
S.c
Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
❑
9.e.iv
The backgrounds of such cabinet signs must be made
opaque zero light transmission).
1E
REF
CHECKLIST ITEM
NOTES
5.e
External illumination should be shielded and not create
, j(
Tare.
j" I
All external light sources shall be white.
❑
93i
Sign lighting (external) should be shielded so that it
illuminates only face of the sign and does not shine beyond
the edge of the sign.
❑
93ii
Channel letters with translucent faces must have no light
spilling outward from the top, bottom, sides or back.
Faces and returns of channel letters shall be opaque when
back -lit (halo -lit).
9JV
Cabinet signs shall have a non -illuminated background, or
an opaque zero light transmission background.
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
5.g
All illumination shall be non -blinking.
❑
S.h
An exposed light source that forms the body of a sign,
(such as exposed neon signs), shall not be used in the
Entrance Corridors.
ARB ACTIONS
❑
Deleted
follomnThe
,,. must state
LED lighting the
if proposed sign,i,-�,�,;
Me LED 1014
le el proi,ided t4y
6/3/19
_ , ,
5
ARB3
30
action
Action on ARB-P
Red acrylic #2283 has been determined to be an
(BP)2001-12
inappropriate color for signs. Pantone color match
+
Wood Grill
for 2283 is 485C. Red #2793 has been approved
as an acceptable substitute. Pantone color match
for 2793 is 187C. See below.
12/21/15 action on
Generally, for signs in the Entrance Corridors, red 485
j'j
REF
CHECKLIST ITEM
NOTES
ARB 2015-114 & -
may be acceptable on a case -by -case basis as a
115 Shell Signs
secondary color.
ARB
Visual clutter resulting from adjacency, for example at the
Action
Hardee's locations, is a reasonable basis for not allowing
)d
Memo:
illumination of the graphic.
5/7/ 12
ARB
Accent color letters can be used in a sign when portrayed
Action
as a graphic, up to 33% of the length of the sign.
Memo:
8/3/2015
°�, r
Completeness Check for Ji11nS CO ltl�
1",V°
Project #/Name: f 1121'j ` 24 q La ym e i o Y, V ✓ 1 d'
Date Received at County: j�(l
Date Received in Design Planning: it
Date of Checklist Check: [ i I �� Assigned to/Date:
3. ARB Review — Will the permanent sign(s) be constructed in an Entrance Corridor?
(See the Entrance Corridor map in the Sign Permit Application packet for a list of Entrance Corridors)
❑ Yes ('Phis sign will be constructed in an Entrance Corridor and it does not meet the conditions of a $129.00
Comprehensive Sign Review. See ARB requirements next pages.) -
❑ Yes (This sign will be constructed in an Entrance Corridor and it does meet the conditions of a C� Waive Fee J
Comprehensive Sign Review. See ARB requirements next pages.)
❑ No ('Phis sign will not be constructed in an Entrance Corridor) $ 0.00
FEE TOTAL (Please add all the amounts checked in sections 1 — 3): $
FREESTANDING SIGNS
A. Submittal Requirements
❑ Site plan or latest approve-4plat showing, to scale, the proposed location of the sign(s) with dimensions.
❑ Distance from the sign to the pro lines and/or edge of the VDOT right-of-way.
❑ If the sign will be located in an easemen , letter of approval from the easement holder will be required.
❑ A to -scale color illustration of the proposed sign sho 'ng
❑ Dimensions of the sign, including overall height from e ground- inet size, length, width and depth; base
size, etc. (Be sure to also include these dimensions on the dia provided in the Sign Permit Application packet.)
❑ Proposed lettering and/or graphics in their pro d location.
❑ Entrance Corridor Requirements: If the ' is to be constructed in Entrance Corridor, also provide a color
illustration of the front and side elev . ns of the sign showing:
o If internally illuminated, i cate which areas of the sign are opaque and ich are illuminated. Internally
illuminated cabinet s' s must have opaque backgrounds. (Opaque materials don't allow light to pass through.
When lit only fr behind, the color of an opaque material cannot be detected nor can objects be seen through it.)
o Identificat' of proposed materials and colors. Include standard color id numbers (Pantone, Benjamin Moore,
Etc ' , etc.) for all materials, text, graphics, base, faces, trim caps, returns, etc.
o Provide accurate physical samples of all colors proposed, preferably in the material proposed. (Paint chips that
accurately reflect the proposed colors are acceptable.)
o Provide a site plan showing proposed landscaping around the sign, including botanical names and planting sizes.
o Additional submittal materials may be required if review by the Architectural Review Board is necessary. (The
applicant will be notified if this requirement applies.)
rom
rn
WALLS� SIGNS
A drab `ing, to scale, showing dim sions of the sign (length, height, depth).
Elev tion drawing(s) or modified photograph of the entire building, to scale and in col showing
The sign locAion on the building, sign helort above grade, and the length of bui ding frontage. (Be sure to also
include these dimensions on the diagrams provided in Appendix B.)
Sign lettering and/or graphics in their proposed location.
❑ Entrance Corridor Requirements: If the sign is to be constructed in an Entrance Corridor also provide a color
illustration of the front and side elevations of the sign showing:
Indication of sign type (channel letters, cabinet, panel, etc.).
o ndicate on the drawings the proposed materials and colors. Include standard color identification numbers
Pantone, Benjamin Moore, Acrylic, etc.) for all materials, text, graphics, faces, trim caps, etc. For channel letter
signs, indicate on the drawing that the raceway color shall math the color of the wall to which the raceway is
attached.
o Provide accurate physical samples of all colors proposed in the sign, preferably in the material proposed. (Paint
chips that accurately reflect the proposed colors are acceptable.)
�✓Location of proposed light fixtures and manufacturer cut sheets describing illumination type, intensity, style,
J shielding, color, and height. All lighting must meet ordinance requirements as outlined in Section 4.17.
or internally illuminated signs, indicate which areas of the sign are opaque and which are illuminated. (Opaque
�' materials don't allow light to pass through. When lit only from behind, the color of an opaque material cannot be
Nf
detected nor can objects be seen through it.
ILLU NATION REQUIREMENTS h ova rr�
The location of proposed light fixtures identified on a plan and/or elevation
Manufacturer cut sheets describing illumination type, intensity, style, shielding, color, and height. All lighting must
meet ordinance requirements as outlined in Section 4.17 of the Zoning Ordinance.
NOTES:
E
-7 7
jq'o"'k_"�
STONEFIELD TOWN CENTER SIGN CRITERIA —This table outlines the approv design criteria for the north elevations of B2 and 63; the south elevations of A3, A4, C1-2 and C1-3; the east elevations of A3 (adjacent to the EC) and C1-2; and the
west elevations of A4 and C1-3 in the Stonefield Town Center. �l
SIGN TYPE
Facade Signs * umbers corresp d to
Projecting Signs
Canopy Signs
Awning Signs
Blade Signs
ilhimir ion details)
)Channel �Z
Panel with pus rough
letters - v.�ty
letters/gra cs
2. Reverse channel letters.
3. Panel with push -through
tters/graphics
SIGN LOCATION
As noted on elevatio s. Minimu 8"
As noted on elevations
On any canopy
On valance of type 1 awnings only
In close proximity to storefront entry
cle rance to archite�Etural feature 10
doors; aligned with architectural
cl arance to top/�ttom of mount
features of storefront and facade.
area. Panel signs my allowed on
May be outside area designated on
Building Al, A5 and B1 facades that do
elevation drawings.
not have frontage on the Entrance
Corridors.
SIZE LIMITATIONS
Letter height max 30". Signs must be in
Signs must be in proportion with other
Letter height max 10". Logo and
Located on valance only
3' x 1'6"
roportion with other signs and the
signs and the overall building.
graphic signs max 10". Signs must be
overall building.
in proportion with canopy face, other
signs, and the overall building.
PROJECTION LIMITATIONS
/A
36" Max projection from face of wall
N/A
N/A
9' minimum clearance from grade.
9'-0" min clearance from grade level
LETTER COLOR
Black, hite arm Grays (Pantone
Black, White, Warm Grays (Pantone
Black, White, Warm Gray.
Unlimited
Black, White, Warm Gray
Warm Gray 1-11)
Warm Gray 1-11)
Match/harmonize with canopy
color/material
TRIM CAP/RETURN COLOR
Tri ap color to match return color.
N/A
N/A
N/A
N/A
eturn colors are Black, White, Warm
Grays.
BACKGROUND/PANEL/BODY
Black, White, Warm Grays (Pantone
Black, White, Warm Grays (Pantone
N/A
Awning colors: Sunbrella Black 08,
Unlimited
COLOR
Warm Gray 1 ; 11)
Warm Gray 1-11)
Natural 04, Charcoal Gray 44, Navy
Blue 26, Alpine Green 55, Panorama
Taupe 48
MOUNTING DETAILS
M ted to exterior wall
Mounted to exterior wall
Mounted to canopy face. Sign
Printed on awning valance
-
elements cannot extend above or
below canopy edges.
GRAPHICS
olors and illumination are subject to
Colors and illumination are subject to
Unlimited
Unlimited
Colors and illumination are subject to
review
review
review.
ILLUMINATION DETAILS
*Numbers correspond to sign type
Halo -Illuminated push -through
Non -illuminated
Non -illuminated
Non -illuminated
External Illumination
jn {j1
2. Halo Illumination
3. Halo-Illuminatedpush-throu h
LETTER TYPE/FONT LX
limited
Unlimited
Unlimited
Unlimited
MATERIALS
Unlimited
Unlimited
Unlimited
Fabric