Loading...
HomeMy WebLinkAboutARB202000023 Plan - Other (not approved) 2020-03-11JINN UC IAIL J AHHHUVEU " AHHHUVEU W/HEVISIONSI Ht5UbN l I Face -lit Channel Letters CUSTOM ARTWORK Overall Size: 134.29" w x 24" h Letter Copy 1: 24in Letters: TC Faces: White 3/16" Acrylic Digital Print: Double Layer - Made from GF22460 3.2mil Matte White Trans 60" with GF23160 2.4mil Gloss ClearUV 60" Letter Copy 2: 15.56in Letters: nas , 24in Letters: it II Faces: White 3/16" Acrylic Logo 1: Qty 1 - 20.95" (H) x 15.2" in (W) Logo Logo (&) Faces: White 3/16" Acrylic Digital Print: Double Layer - Made from GF22460 3.2mil Matte White Trans 60" with GF23160 2.4mil Gloss ClearUV 60" All Trim: Black All Returns: Black LEDs: 1 Row of LED Power Supply: LED Power Supply -Principal PL-60-12-U 100-277VAC Mount Type: Remote Outdoor UL Listed Sizing & Color Revisions - 3.11.2020 24" 134.2911 ON 6 N Logo Box 15.2" � a a 0O 0 Black outline represents black trim cap. NOT to be on the face of the letters. PLEASE NOTE THAT COLORS MAY NOT CONVEY ACCURATELY WHEN VIEWED, MEASUREMENTS ARE NOT TO SCALE, White 99 1935 C 24" Client: Location: SIGN PLACEMENT MAY CHANGE we cannot guarantee exactcolor matcbes. Drawing scale: Proportional 2165 Seminole Trail Layout by: Kristyn Jones �x Preliminary Drawing Drawing location: //IGHTECiH Charlottesville, VA 22901 phone: (434) 974-7900 x100 Final Drawing illustrated for pdimensionsiooproject client's conception of project and are not to be Aient's conception SIGNS kjones@htsva.com PAGE 1 OF 3 Phone/Email: understood as being exact size of exact scale, Revision #:1 Copyright Warning:This is an original unpublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains theproperty of Hightech Signs until legally purchased. SIGN DETAIL ❑ APPROVED ❑ APPROVED W/REVISIONS❑ RESUBMIT PLEASE NOTE THAT COLORS MAY NOT CONVEY ACCURATELY WHEN VIEWED. MEASUREMENTS ARE NOTTO SCALE. Client: Location: slcN PLAcerneNr MAY crlANce we cannot guarantee exact color an 'has. Drawing scale: Proportional Drawing location: I JIGHTECH 2165 Seminole Trail Layout by: Kristyn Jones Charlottesville, VA 22901 phone: (434) 974-7900 x100 x❑ Preliminary Drawing ❑ Final Drawing TSC All sizes and dimensions are illustrated for client's conception of project and are not to be SIGNS (f Ones@htsva.cOm Phone/Email: understood as being exact size of exact scale. Revision #: 1 PAGE 2 OF 3 Copyright Warning:This is an original unpublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased. blUIV UL AIL " APPROVED " APPROVED W/REVISIONS" RESUBMIT Channel Letter Install Diagram CUSTOMER TO PROVIDE: ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. IF NEEDED, CUSTOMERTO PROVIDE ALL SIGNAGE DRAWINGSTO LANDLORD FOR FINAL APPROVAL. SIGNED COPIES OF ALL FINAL SIGNAGE DRAWINGS AND QUOTES. A. ALL BRANCH CIRCUITS MUST BETOTALLY DEDICATED TO SIGNS (INCLUDING DEDICATED GROUND AND DEDICATED NEUTRAL PER CIRCUIT). B. SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS SUCH AS LIGHTING, AIR CONDITIONING, AND OTHER EQUIPMENT. C. PROPERLY SIZED GROUND WIRE THAT CAN BE TRACED BACKTO THE BREAKER PANEL MUST BE PROVIDED. D. NUMBER AND SIZE CIRCUITS FOR EACH SIGN TO MEET ANY LOAD REQUIREMENTS. INSTALLER IS RESPONSIBLE FOR: PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS (AS LONG AS DEDICATED HOOK UP IS WITHIN 5'OF SIGN) PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION AT EXTERIOR LOCATIONS. NOTE:THE LEVEL OF ILLUMINATION PROVIDED BYTHE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON. PLEASE NOTE THAT COLORS MAY NOT CONVEY ACCURATELY WHEN VIEWED. MEASUREMENTS ARE NOTTO SCALE. FACE -LIT LED FLUSH MOUNT CHANNEL LETTER SECTION DETAIL 1 INSTALLATION INSTRUCTIONS 1. EXISTING WALL 2. ACRYLIC FACES 3. STAI NLESS STEEL SCREW ATTACH Ml 4. ALUMINUM BACKS 5. ALUMINUM RETURNS 6. WALL FASTENERS, PER ENGINEER 7. LED UNITS S. LED POWER SUPPLY 9. TRANSFORMER BOX 10. 120V USTED DISCONNECT SWITCH 11, PRIMARY ELECTRICAL SOURCE(1/2"MIN. CONDUIT) NEC 600-6 & 600-21 12. WEATHERPRDOFCONDUIT/PASSTH ROUGH 13. BRANCH CIRCUIT (WIRING HOTTO HOT NEUTRAL TO NEUTRAL, GROUN D 11 TO GROUND) BY OTHERS 14. UL RATED WIRENUTS 15. PREMIUM LED CABLE 16. DRAIN HOLES WI LIGHT COVERS 17. FASTENE RS AS I UIRED 18. 1 112" STAND OFF Client: Location: SIGN PLACEMENT MAY CHANGE We guarantee exact color matches , Drawing scale: Proportional Drawing location: H1GHTECH 2165 Seminole Trail Layout by: Kristyn Jones Charlottesville, VA 22901 phone: (434) 974-7900 A00 0 Preliminary Drawing Final Drawing Iannet All sizes and dimensions are illustrated for client's conception of project and are not to be SIGNS kjones@htsva.com Phone/Email: understood as being exact size of exact scale. Revision#:1 PAGE 3 O F 3 Copyright Warning:This is an original unpublished design created by Hightech Signs It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever It remains the property of Hightech Signs until legally purchased.