HomeMy WebLinkAboutARB202000023 Plan - Other (not approved) 2020-03-11JINN UC IAIL
J AHHHUVEU " AHHHUVEU W/HEVISIONSI Ht5UbN l I
Face -lit Channel Letters
CUSTOM ARTWORK
Overall Size: 134.29" w x 24" h
Letter Copy 1: 24in Letters: TC
Faces: White 3/16" Acrylic
Digital Print: Double Layer - Made from GF22460 3.2mil Matte White Trans 60" with GF23160 2.4mil Gloss ClearUV 60"
Letter Copy 2: 15.56in Letters: nas , 24in Letters: it II
Faces: White 3/16" Acrylic
Logo 1: Qty 1 - 20.95" (H) x 15.2" in (W) Logo Logo (&)
Faces: White 3/16" Acrylic
Digital Print: Double Layer - Made from GF22460 3.2mil Matte White Trans 60" with GF23160 2.4mil Gloss ClearUV 60"
All Trim: Black
All Returns: Black
LEDs: 1 Row of LED
Power Supply: LED Power Supply -Principal PL-60-12-U 100-277VAC
Mount Type: Remote
Outdoor UL Listed
Sizing & Color Revisions - 3.11.2020
24"
134.2911
ON
6
N
Logo Box
15.2"
�
a a 0O 0
Black outline represents black trim cap. NOT to be on the face of the letters.
PLEASE NOTE THAT COLORS MAY NOT CONVEY ACCURATELY WHEN VIEWED, MEASUREMENTS ARE NOT TO SCALE,
White
99
1935 C
24"
Client:
Location:
SIGN PLACEMENT MAY CHANGE
we cannot guarantee exactcolor matcbes.
Drawing scale: Proportional 2165 Seminole Trail Layout by: Kristyn Jones �x Preliminary Drawing
Drawing location: //IGHTECiH Charlottesville, VA 22901 phone: (434) 974-7900 x100 Final Drawing
illustrated for
pdimensionsiooproject
client's conception of project and are not to be
Aient's conception
SIGNS kjones@htsva.com PAGE 1 OF 3
Phone/Email:
understood as being exact size of exact scale,
Revision #:1
Copyright Warning:This is an original unpublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains theproperty of Hightech Signs until legally purchased.
SIGN DETAIL
❑ APPROVED ❑ APPROVED W/REVISIONS❑ RESUBMIT
PLEASE NOTE THAT COLORS MAY NOT CONVEY ACCURATELY WHEN VIEWED. MEASUREMENTS ARE NOTTO SCALE.
Client:
Location:
slcN PLAcerneNr MAY crlANce
we cannot guarantee exact color an 'has.
Drawing scale: Proportional
Drawing location:
I JIGHTECH
2165 Seminole Trail Layout by: Kristyn Jones
Charlottesville, VA 22901 phone: (434) 974-7900 x100
x❑ Preliminary Drawing
❑ Final Drawing
TSC
All sizes and dimensions are illustrated for
client's conception of project and are not to be
SIGNS
(f Ones@htsva.cOm
Phone/Email:
understood as being exact size of exact scale.
Revision #: 1
PAGE 2 OF 3
Copyright Warning:This is an original unpublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased.
blUIV UL AIL
" APPROVED " APPROVED W/REVISIONS" RESUBMIT
Channel Letter Install Diagram
CUSTOMER TO PROVIDE:
ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE.
IF NEEDED, CUSTOMERTO PROVIDE ALL SIGNAGE DRAWINGSTO LANDLORD FOR FINAL APPROVAL.
SIGNED COPIES OF ALL FINAL SIGNAGE DRAWINGS AND QUOTES.
A. ALL BRANCH CIRCUITS MUST BETOTALLY DEDICATED TO SIGNS
(INCLUDING DEDICATED GROUND AND DEDICATED NEUTRAL PER CIRCUIT).
B. SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS SUCH AS LIGHTING, AIR CONDITIONING, AND OTHER EQUIPMENT.
C. PROPERLY SIZED GROUND WIRE THAT CAN BE TRACED BACKTO THE BREAKER PANEL MUST BE PROVIDED.
D. NUMBER AND SIZE CIRCUITS FOR EACH SIGN TO MEET ANY LOAD REQUIREMENTS.
INSTALLER IS RESPONSIBLE FOR:
PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING
(CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS
(AS LONG AS DEDICATED HOOK UP IS WITHIN 5'OF SIGN)
PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS.
SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION AT EXTERIOR LOCATIONS.
NOTE:THE LEVEL OF ILLUMINATION PROVIDED BYTHE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED
BY A SINGLE STROKE OF 30 MILLIAMP (MA) NEON.
PLEASE NOTE THAT COLORS MAY NOT CONVEY ACCURATELY WHEN VIEWED. MEASUREMENTS ARE NOTTO SCALE.
FACE -LIT LED FLUSH MOUNT CHANNEL LETTER
SECTION DETAIL 1
INSTALLATION INSTRUCTIONS
1. EXISTING WALL
2. ACRYLIC FACES
3. STAI NLESS STEEL SCREW ATTACH Ml
4. ALUMINUM BACKS
5. ALUMINUM RETURNS
6. WALL FASTENERS, PER ENGINEER
7. LED UNITS
S. LED POWER SUPPLY
9. TRANSFORMER BOX
10. 120V USTED DISCONNECT SWITCH
11, PRIMARY ELECTRICAL SOURCE(1/2"MIN.
CONDUIT) NEC 600-6 & 600-21
12. WEATHERPRDOFCONDUIT/PASSTH ROUGH
13. BRANCH CIRCUIT (WIRING HOTTO HOT
NEUTRAL TO NEUTRAL, GROUN D 11
TO GROUND) BY OTHERS
14. UL RATED WIRENUTS
15. PREMIUM LED CABLE
16. DRAIN HOLES WI LIGHT COVERS
17. FASTENE RS AS I UIRED
18. 1 112" STAND OFF
Client:
Location:
SIGN PLACEMENT MAY CHANGE
We guarantee exact color matches ,
Drawing scale: Proportional
Drawing location:
H1GHTECH
2165 Seminole Trail Layout by: Kristyn Jones
Charlottesville, VA 22901 phone: (434) 974-7900 A00
0 Preliminary Drawing
Final Drawing
Iannet
All sizes and dimensions are illustrated for
client's conception of project and are not to be
SIGNS
kjones@htsva.com
Phone/Email:
understood as being exact size of exact scale.
Revision#:1
PAGE 3 O F 3
Copyright Warning:This is an original unpublished design created by Hightech Signs It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever It remains the property of Hightech Signs until legally purchased.