HomeMy WebLinkAboutARB201900146 Review Comments Final Site Plan and Comps. 2020-03-16COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832
March 16, 2020
Craig Kotarski
Timmons Group
608 Preston Avenue, Suite 200
Charlottesville, VA 22903
Fax (434) 972-4126
RE: ARB-2019-146: Beaver Creek Medical Office - Final (TMP 06000-00-00-03800)
Dear Mr. Kotarski,
We have received revised site plans and architectural plans for the above -noted application that
address the conditions of approval the Architectural Review Board requested at its January 6, 2020
meeting. The following revisions are requested to make the proposal consistent with those
conditions as well as the Entrance Corridor design criteria.
1. Provide a perspective view showing the northeast corner of the building and the entrance to
the underground parking as viewed from the EC.
Rev. 1: Comment addressed.
2. Provide information on the VLT and VLR ratings for the window glass. Ensure that the glass
meets the required limits.
Rev. '1: Comment addressed.
3. Add the standard window glass note to the drawings with the next submission: Visible light
transmittance (VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not
exceed 30%.
Rev. 1: Comment addressed.
4. Provide a material sample for the aluminum panel mechanical roof screen.
Rev. 1: Comment addressed.
5. Revise the east building elevation labels to clearly state the materials and colors of all
components of the building, including spandrel glass, if proposed.
Rev. 1: Comment not yet fully addressed. Address the following:
a) Ensure that the color is provided for each of the components in the elevation. The
following do not have their colors listed on the elevation:
i. The stone veneer
ii. The Wood -Look Panel
iii. The Aluminum Storefront System
iv. The Precast Concrete Panels
v. The Aluminum Sunshade System
vi. The Aluminum Panel Mechanical Roof Screen
vii. The Aluminum Glazing Infill Panels
viii. The Aluminum Curtain Wall System
b) Ensure that "Light Beige" and "Dark Beige" colors are the actual manufacture's color
names and not a general description of the color.
6. Revise the materials information on the east building elevation to specify that all window
glass is not tinted or provide window glass samples for review.
Rev. 1: Comment addressed.
7. Include the type, manufacturer and color of the material utilized in the dumpster enclosure in
the dumpster detail.
Rev. 1: Comment not vet fully addressed. Address the following:
a) Revise the "Detail — Concrete Dumpster Pad" to no longer state in a label "Refer to
architectural plans for enclosure details" or clarify where on the architectural plans the
additional details are provided.
b) Add a note or label that specified that the screening fence is opaque.
8. Provide a roof plan showing the location and height of the rooftop mechanical equipment.
Revise the elevation views to include dashed lines for the rooftop mechanical equipment.
Confirm the reason for not showing the roof screen in the perspective views.
Rev. 1: Comment not yet fully addressed. Address the following:
a) Revise the roof plan to include the maximum height of the roof top equipment.
b) Revise the roof plan to specify the height of the Aluminum Mechanical Screen Wall.
c) If this information has been provided on a different sheet, as appears to be the case
from Roof Plan note #2, those sheets could be provided.
9. Revise the plan to include all building mounted lighting and extend the lighting calculation
grid to the EC.
Rev. 1: Comment not vet fully addressed. Address the following:
a) Ensure that all lighting meets the requirement of "The spillover of lighting from
luminaires onto public roads and property in residential or rural areas zoning districts
shall not exceed one half footcandle." This requirement is not being met in the following
places:
i. Along the right of way of Ivy Road.
ii. Along the southern property boundary, where it is adjacent to TMP 60-4005.
b) The S3 (WPLED26N) light fixture is above 3,000 lumens. Because of its curved bottom
it does not appear to be full cutoff. All light fixtures above 3,000 lumens must be full cut
off in design. Revise the site plan to meet this requirement.
10. Ensure that the photometric plan was calculated using a Light Loss Factor (LLF) of 1.0 and
note this on the plan.
Rev. 1: Comment addressed.
11. Revise the lighting plan to include the color of the light poles.
Rev. 1: Comment initially specified was addressed. However, the height of the poles has
been revised since the last submission. Revise the pole mounted fixture heights, listed on
sheet SE1.0 to specify that the freestanding pole mounted fixtures do not exceed a height of
20'.
12. Revise the lighting plan to include the standard lighting note. "Each outdoor luminaire
equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire
and shall be arranged or shielded to reflect light away from adjoining residential districts and
away from adjacent roads. The spillover of lighting from luminaires onto public roads and
property in residential or rural areas zoning districts shall not exceed one half footcandle."
Rev. 1: Comment addressed.
13. Revise the plan to provide 3%2 inch caliper large shade trees along the EC.
Rev. 1: Comment addressed.
14. Revise the label for the "temporary easement for entrance" in the site plan to indicate when
the easement is to be vacated. Show how the easement will not conflict with the proposed
building or landscaping.
Rev. 1: Comment addressed. Applicant has stated that "... this easement will expire upon
completion of the Ivy Road sidewalk protect construction.... Beaver Creek MOB construction
will be coordinated with the County to ensure that it doesn't interfere with the Ivy Road
sidewalk proiect."
15. Revise the plan to provide a minimum of 5' between proposed trees and the gas line.
Shifting the sidewalk closer to the building and locating the trees closer to the curb may be
an option.
Rev. 1: Comment addressed.
16. Revise the site plan to increase the clearance between the large shade tree that is adjacent
to the parking lot, and within 2' of the gas line, and the gas line.
Rev. 1: Comment addressed.
17. Revise the site plan to add one small tree along the east perimeter of the parking area.
Rev. 1: Comment addressed.
18. Move the two large trees away from the dumpster to other interior islands within the
southern parking row to avoid damage.
Rev. 1: Comment not yet fully addressed. Although the dumpster has been relocated to
avoid conflict with the required landscaping, the modifications made require that the
following to be addressed:
a) The sugar maple iust to the south of the dumpster area is still to close and would be
damaged by the trash truck. Move the tree at least 5' further south.
b) Revise the site plan to include a total of eight interior parking lot trees. Parking lot
islands have been removed from the southern most row of parking spaces. Although
there are now trees along the perimeter of the parking lot they meet the "perimeter'
parking lot tree requirements and do not meet the "interior' parking lot tree requirement.
There should be one large shade tree in the interior of the parking lot for every ten
parking spaces. Therefore eight interior trees should be provided and only six interior
parking lot trees are currently shown within the parking lot. Two more trees could be
included by adding two landscaping islands within the southern most row of parking.
19. Sign applications are required for all proposed signs.
Rev. 1: Comment addressed. Applicant has stated that an application for any signage will
be submitted.
20. If this will be a multi -tenant building, submit a comprehensive sign plan for review. Rote that
ARB approval of a comprehensive sign plan is required for multi -tenant buildings prior to
ARB approval of the final site plan.
Rev. 1: Comment addressed. Applicant has stated that the building is intended to be a
single tenant building.
21. Incorporate relief in the fiber cement facade, possibly through change in plane between the
wood fiber cement and the other cladding.
Rev. 1: Comment not yet fully addressed. Although a description of what is intended to
meet this condition of approval was included in the comment response letter it does not
appear that any details have been provided in the architectural drawings that show this
information. Also the 3" relief specified may not be sufficient. Revise the architectural
plans to include a detail showing what is proposed to accomplish the relief in the fiber
cement facade and then those details will be forwarded to the ARB for their review and
comments.
Within 15 days of the date of this letter, please send me a letter (by email is acceptable) indicating
whether you will or will not proceed with these revisions. If you choose not to proceed with these
revisions, staff will be unable to approve your application. If you choose to proceed with the
revisions, please forward me two set of revised drawings together with a memo summarizing the
revisions you've made. Your decision to make the revisions will suspend the 60-day review period
associated with your original submittal. However, I expect to complete the review of your revised
proposal within 2 weeks of your re -submittal.
If you have any questions about this action, please contact me as soon as possible. I look forward to
receiving your revisions and completing this review with an approval letter.
If you have any questions, please do not hesitate to contact me.
Sincerely,
Paty Sate e
Senior Planner
psaternye@albemarle.org
cc: John Their
2246-2248 Ivy Road LLC
P.O. Box 13
Ivy, VA 22945
File
COUNTY OF ALBEMARLE
Department of Community Development
REVISED APPLICATION SUBMITTAL
This form must be returned with your revisions to ensure proper tracking and distribution.
County staff has indicated below what they think will be required as a resubmission of revisions.
If you need to submit additional information, please explain on this form for the benefit of the
intake staff. All plans must be collated and folded to fit into legal size files, in order to be
accepted for submittal.
TO: Paty Saternye DATE:
PROJECT NAME: ARB2019-146 Beaver Creek Medical Building
Submittal Type Requiring Revisions () indicates
Submittal Code
County Project Number
# Copies
Erosion & Sediment Control Plan E&S
Mitigation Plan MP
Waiver Request WR
Stormwater Management Plan SWMP
Road Plan RP
Private Road Request, with private/public comparison
PRR
Private Road Request — Development Area PRR-DA
Preliminary Site Plan PSP
Final Site Plan or amendment FSP
Final Plat FP
Preliminary Plat PP
Easement Plat EP
Boundary Adjustment Plat BAP
Rezoning Plan REZ
Special Use Permit Concept Plan SP-CP
Reduced Concept Plan R-CP
Proffers P
Bond Estimate Request BER
Draft Groundwater Management Plan D-GWMP
Final Groundwater Management Plan F-GWMP
Aquifer Testing Work Plan ATWP
Groundwater Assessment Report GWAR
Architectural Review Board ARB
ARB2019-146
2
Other: Please explain
For staff use onl
Submittal
Code
#
Copies
Distribute To:
Submittal
Code
#
Copies
Distribute To:
ARB
2
Paty Saternye