HomeMy WebLinkAboutSDP202000030 Correspondence 2020-03-240.2
0.1
0.1
A,
Not to Scale
.0
0 It
CONC. PAD\
/\ W/ UT
1 A'1�2.4
Fi
6
A
0.2
1.
0
.4
A
0•
0.7
1.1
1.7
1.6
1.4
1.3
.�
0
1.0
1.8
2.6
3.0
2.9
2.4
1.9
1.4
1.1
1.0
5.4
A .6
0.8
1.5
3.9
4.8
4.8
4.0
3.0
2.1
1.4
1
0.8
0.
.4A 7
0
3.5
5.3
6.7
5.6
4.1
2.7
.8
1.3
1.0
1.
1.2
1.4
0.
0.7
1.3
2.5
4.2
6.4
8.1
7.9
6.
4.6
.0
2.0
1.5
1.3
1.
1.6
1.9
2.
Q�
0.3
SL5
0.9
1.6
2.8
4.5
6.5
.9
7.7
6.4
2.
2.0
1.6
1.5
.7
2.2
2.9
3.6' � E
0.3
0.6
0.9
1.5
2.6
3.9
5.4
6.4
6.
5.3
3.
2.
1.8
.6
1.7
2.1
3.0
4.4
5.7 .1
0.3
0.7
1.0
1.4
2.1
2.9
.9
.6
4.7
4
.0
1
1.5
1.
2.4
.7
5.6
0.4
\0.8
Q
0.6
1.0
1.3
1.7
2.1
2.
3.0`
2.9
2.3
1.8
1.5
1.
2.5
4.1
6.0
SL4
0.4
\0:9
0.4
0.7
1.1
1.4
1.6
1
2.
2.2
.2
0
1.
1.3
1.6
2.2
3:2
4.4
4
0.4
0.9
1.2
1.4
6
1.8
9
1.8
.6
1.4
1.
1.1
1.1
.3
1.7
2.1
0.3 0.7
1.1
1.5
1.8
.2
2.5
2.4
.8
1.5
1.2
1.0
0.9
1.0
.7'
2
2
2
_
10
08
.2�
0
2.1 3 4. 6.0 5.9 5 3.5 2.5 .8 1.3 1. 0 .3
0.3
.2 3.6 5.7 .8 8.2 6.4 4. 2.8 1.8 0.3
0.2
.4 2.4 3.8 SL 6.5 4.3 0.2
03
0.2
0.1
.1
0.4
0.5
0.4
0.4
0.4
0.3
.3
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.2
0.2
.3
0
0.4
0.4
Luminaire Data
Label
Qty
Symbol
Manufacture
Description
LLF
Arr. Watts
Arr. Lum. Lumens
A
7
0
Liton Lighting Inc
DL36RW-T50
0.720
34.18
1888
SL5
1
{]]
BARRON LIGHTING GROUP
RxA-200-5-VS-5K
0.850
200.249
25880
SL4
2
{]]
BARRON LIGHTING GROUP
RXA-200-4-VS-4K
0.720
204.6
24709
Calculation Values
Label
CalcType
Units
Avg
Max
Min
Avg/Min
Max/Min
Parking
Illuminance
Fc
2.64
8.2
0.6
4.40
13.67
Porch
Property Line
Illuminance
Fc
6.74
12.4
2.6
2.59
4.77
Illuminance
Fc
0.15
0.5
0.0
N.A.
N.A.
NOTES:
1. The calculated results of this lighting simulation represent a prediction of system performance and are not guaranteed.
2. Actual measured results may vary from the anticipated performance and are subject to means and conditions which
are beyond the control of DB Lighting Consultation.
3. Illumination values shown (in foot-candles) are horizontal at grade level based on Mounting Height 20'-0"
4. Calculation points are on an 8' x 8' spacing
5. Per fixture isolines shown represent 0.25 fc and is for reference only
�o
�o�
�
c�
J
U
�
N
�
N
O
U
"-
�
V
cn
Z
rn
T
rn
T
o
N
O
r
N
0
O
O
M
O
Q m U
Revisions0.1
U fA
O 0 (0 O
(0 uj d O f0
��� im
�oC�
O O 7 (�
O . i� d cot U c
c N Q O O
CZ
s)- Q�
o2-LS 'o
y (0 U '� U
E O U 7> U U
�, -
N � U 0
N
O 02 CZ
0
�J O2 �_ N
0
01� N 0,
O y
7_ > 1 co
• O E C N
� CZ•5�
•=v -2-0 C U U
'+ s a d d - �
w .- d 7 O d=
Y/ - 6 "O CZ Q :� Q
PE2a)E E
Q �a)om
J� Q E U (Z U
00
N
Z
� U
�k
G cc
N }'
> v
p O
a� a
o -
o
U rn
T
0 0
E 00
Z o
� o
v �
2 6,
�O R
a o 0
U)
■� Q
U
2411 x 36"