Loading...
HomeMy WebLinkAboutSDP201800076 Letter of Revision 2020-03-25COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 March 25, 2020 Timothy Miller 440 Premier Circle, Ste. 200 Charlottesville, VA 22901 RE: LOR # 1 for SDP201800076; Earlysville Business Park Tax Map/Parcel Number 03100-00-00-021AO Dear Mr. Miller, Fax (434) 972-4126 This letter is in response to the attached Letter of Revision Request dated February 20, 2020. The Department of Community Development hereby grants approval of this LOR for the following modifications to SDP2018-76, depicted on the modified site plan and described below: 1. Revise curb returns at entrance to parking lot for existing buildings 2. Revise stormwater conveyance channels from concrete to sod This change is noted in the attached request and plan. This is the first Letter of Revision for this site. A total of three LORs may be requested after which any further changes to the plan will require submission in the form of a site plan amendment application. Sincerely, 4 Jeff P. Baker Senior Planner Attachments: Letter of Request & Application Site Plan ;. J Engineering • Surveying • Planning February, 20, 2020 Chris Perez Senior Planner 401 McIntire Road Charlottesville, VA 22902 RE: FIRST LETTER OF REVISION FOR SDP 2018-00076 .M:INOR SITE PLAN AMENDMENT FOR EARLYSVILLE BUSINESS PARK Dear Chris; MERIDIAN PI ANNINC; t: i our, LLC 440 Premier Circle, Suite 200 Charlotte ville, VA 22901 Phone: 434.882.0121 ivtv%v. rnerid ian vvbe. com Attached are four copies of the Letter of Revision for Earlysville .Business Park; and the Application for Letter of .Revision. The approved plan that this change applies to is titled `Minor Site plan Amendment .for Earlvsville Business Park' SDP2018-00076. The purpose of this revision are as follows: 1. Revise curb returns at entrance to parking lot for existing building. 2. Revise stormwater conveyance channels from concrete to sod. Please let me know if you have any questions or need additional information. Sincerely, Timothy Miller, P.E., L.S. Principal Application for Letter of Revision M Letter of Revision = $108 This application may require additional review by the Fire Marshal. Fees in addition to those shown on this application may be required as required by the Fire Prevention Code Fee Schedule. A copy of the schedule is available from the Fire Marshal. Final Site Plan Name and Number: SDP 201800076 Minor Site Plan Amendment for Earlvsville Business Park Contact (who should we contact about this project) Timothy Miller. Street Address 440 Premier Circle, Ste 200 Cit, Charlottesville State VA Zip Code 22901 Phone Number• 434-882-0121 Email tmiller@meridianwbe.com Owner of Record4F, LLC Street :Address 2885 Earlysville Road C:it,. Earlysville State VA Zip (:ode 22936 Phone Number Email Applicant Same as Owner Street Address Cit", State Zip Code Phone Number Email SLBMITTAL REQUIREMENTS: ® The appropriate fee. W 'llie site plan number that the cliange applies to, 10 ?. request letter describing the proposed changes from the owner or authorized agent. W 4 copies of die plan that shows the proposed changes, Changes must be shown on the sheet or sheets from the approved final site Ulan, or on an 1 I":k 17' copy of that portion of the approved final site plan. Owner/Applicant Must Read and Sign I hereby certify that the intonnation provided on this application and acconipanyin'a information is accurate, true and correct to dte best of my knowledge and belief. 020 Signature o Owne agent Date Print Name Da—yinue phone number of Signatory FOR OFFICE USE ONLY L,OR # 1 Pee Amount S-�-Et.- � Data Paid xcho2 Re zipt � i'k.: 13y: !/y Countv of Albemarle Department of Community Development 401 McIntire Road Charlottesville., VA 22902 Voice: (434) 296-5832 Fax: (434) 972-4126 REVISED 41/23/2018 Page 1 of 1 Shoulder Where applicable APPROVED by he Albemarle County Commuf4y De�t Department Date 3 Z. 2-o i k 5VP"13-"2b Loq-VA v) cn z z z O w w O O U U U L w � z z D D O O U U Q N U-) / �srr---------- / 554-------------- I I \ '\ ` `. I ►: \ \ 552---------------------- 5 = 0.56 Acres I j I I j / /' Ex$I t&Gees - --------- A LOT -65 i I I I I 1 (To Remain) r O I \ � Tc = 5.0 min � r>s-e w 1 0 / - - -- ---------- \ l \ C = 0.75 / 348--------- o \�DBi516- \ i�\�` Q..� (�, gsew G4- -I- kY-5v.ee 5n.50 \SVAI � V 1 I 0 1 STORMWATER CONVEYANCE CHANNELS SCC W D STATION LINER 1 10 1.0 0+00 to 1+43 Sod 2 10 2.0 0+00 to 0+59 Sod LD-268 Roadside Ditch Calculation Earlysville Buisiness Park CA Tc 12 Q2 Additional Flows Total 2-Year Flow 110 Q10 Additional Flows Total 10-Year Flow STA I STA DA C Inc I Acc Lining SCC 1 0 1+43 0.65 0.50 0.34 0.34 5.0 5.5 1.86 0.00 1.86 7.07 2A0 0.00 2.40 Sod SCC 2 0 1 0+59 0.56 0.75 0.42 0.42 5.0 15.5 12.30 1 0.00 1 2.30 17.07 12.97 1 0.00 1 2.97 Sod r•G -- �----------------- I - ------ ® L _ 4 -000sw�, 0 - - - - - - - - - - Exist Trees -_-- _--� - SCC-1 I - - A=0.68 Acres � Tc = 5.0 min --- C=0.50 - - - - ExiTrees __ L------- - (To emain' .01 STORM CONVEYANCE CHANNEL CALCULATIONS SCALE:1 "=60' \' w Q o J Exist Trees � \ -� LJ o W w (To RieitnolQ� SHEET NO. - C�420 60' 0 60' 120' 180' SCALE: 1 "=60' SHEET 6 of 15 Channel Report Hydraflow Express Extension for Autodesk0 AutoCAD® Civil Me) by Autodesk. Inc. SCC-1 2 yr Triangular Side Slopes (z:1) = 5.00, 5.00 Total Depth (ft) = 1.00 Invert Elev (ft) = 100.00 Slope (%) = 25.00 N-Value = 0.060 Calculations Compute by: Known Q Known Q (cfs) = 1.86 Elev (ft) 102.00 101.50 101.00 100.50 100.00 Section Highlighted Depth (ft) Q (cfs) Area (sqft) Velocity (ft/s) Wetted Perim (ft) Crit Depth, Yc (ft) Top Width (ft) E G L (ft) Wednesday, Jan 22 2020 = 0.33 = 1.860 = 0.54 = 3.42 = 3.37 = 0.39 = 3.30 = 0.51 Depth (ft) 2.00 1.50 we 0.50 MM 99.50 ' 1 1 1 1 1 I 1 1 1 1 1 -0.50 0 1 2 3 4 5 6 7 8 9 10 11 12 Reach (ft) Channel Report Hydra flow Express Extension for AutodeskO AutoCADO Civil 3DO by Autodesk, Inc. SCC-1 10 yr Triangular Side Slopes (z:1) = 5.00, 5.00 Total Depth (ft) = 1.00 Invert Elev (ft) = 100.00 Slope (%) = 25.00 N-Value = 0.060 Calculations Compute by: Known Q Known Q (cfs) = 2.40 Elev (ft) 102.00 101.50 100.50 fililiX1111 Section Highlighted Depth (ft) Q (cfs) Area (sqft) Velocity (fUs) Wetted Perim (ft) Crit Depth, Yc (ft) Top Width (ft) EGL (ft) Wednesday, Jan 22 2020 = 0.36 = 2.400 = 0.65 = 3.70 = 3.67 = 0.43 = 3.60 = 0.57 Depth (ft) 2.00 1.50 1.00 0.50 011 99.50 1 ' 1 I I I I I I I I 1 1 -0.50 0 1 2 3 4 5 6 7 8 9 10 11 12 Reach (ft) Channel Report Hydraflow Express Extension for AutodeskO AutoCADO Civil 3DO by Autodesk, Inc. SCC-2 2 yr Triangular Side Slopes (z:1) = 2.50, 2.50 Total Depth (ft) = 1.00 Invert Elev (ft) = 100.00 Slope (%) = 30.00 N-Value = 0.060 Calculations Compute by: Known Q Known Q (cfs) = 2.30 Elev (ft) 102.00 101.50 1 11 100.50 11 1I11 99.50 0 1 2 Section 3 Reach (ft) Highlighted Depth (ft) Q (cfs) Area (sgft) Velocity (ft/s) Wetted Perim (ft) Crit Depth, Yc (ft) Top Width (ft) E G L (ft) 4 5 0 Wednesday, Jan 22 2020 = 0.45 = 2.300 = 0.51 = 4.54 = 2.42 = 0.56 = 2.25 = 0.77 Depth (ft) 2.00 1.50 0.50 1 11 Channel Report Hydraflow Express Extension for Autodesk® AUtoCADO Civil 3DO by Autodesk, Inc. SCC-2 10 yr Triangular Side Slopes (z:1) = 2.50, 2.50 Total Depth (ft) = 1.00 Invert Elev (ft) = 100.00 Slope (%) = 30.00 N-Value = 0.060 Calculations Compute by: Known Q Known Q (cfs) = 2.97 Elev (ft) 102.00 101.50 100.50 U11 M 99.50 0 1 VA Section 3 4 Reach (ft) Wednesday, Jan 22 2020 Highlighted Depth (ft) = 0.49 Q (cfs) = 2.970 Area (sgft) = 0.60 Velocity (fUs) = 4.95 Wetted Perim (ft) = 2.64 Crit Depth, Yc (ft) = 0.62 Top Width (ft) = 2.45 EGL (ft) = 0.87 5 6 Depth (ft) 2.00 1.50 M11 =19 w il, -0.50 7