HomeMy WebLinkAboutSDP200800112 Application Minor Amendment 2008-07-11 Comm Development Department,Zoning&
,� :i�l� County of AL.-marle Current Development Division
g•
- m 401 McIntire Road Charlottesville,VA 22902-4596
1 `
tAGitli, Planning Application 1 Voice:(434)296-5832 Fax:(434)972-4126
PARCEL/ OWNER INFORMATION
TMP `03300-00-00-001D0- Owner(s): IN T.SENERAT,ION L L C
Application#1`,: SDP200800112`,
PROPERTY INFORMATION
Legal Description ACREAGE
Magisterial Dist. Rivanna Land Use Primary Forest
Current AFD Not in A/F District Current Zoning Primary Planned Residential Development
APPLICATION INFORMATION
House# Street Name Apt/Suite City State Zip
Street Address 2090 BOULDERS RD CHARLOTTESVILLE 22911-
Entered By:Lisa Jordan on 07/14/2008
Application Type Site Development Plans
Project: NGIC-Minor 6,054.00
Received Date 07/14/2008 Received Date Final Total Fees $95.00
Submittal Date 07/14/2008 Submittal Date Final Total Paid $95.00
Closing File Date Revision Number
Comments: Also see Tax Map 33 Parcel 1F
Legal Ad
SUB APPLICATION(s)
Type Sub Application Date Comments:
Minor Amendment 07/14/2008
APPLICANT/ CONTACT INFORMATION
Primary Contact
Name Collins Engineering-Scott Collins Phone# (434) 293-3719
Street Address 800 E Jefferson Street Fax # (434) 293-3719
City/State Charlottesville VA Zip Code 22902-0000
E-mail scott@collins-engineering.com Cellular# ( ) -
Owner/Applicant
Name NEXT GENERATION L L C Phone# (434) 975-3334
Street Address P 0 BOX 5548 Fax# (434) 975-0267
City/State CHARLOTTESVILLE VA Zip Code 22905-
E-mail Cellular# ( ) -
Applicant
Name United Land Corporation Phone# ( ) -
Street Address PO BOX 5548 Fax # ( ) -
City/State Charlottesville VA Zip Code 22905-0000
E-mail Cellular# ( ) -
Signature of Contractor or Authorized Agent Date
Application for Mi.jor & Minor Site Plan A11endments
tho
and All Reinstatements of Denied or Deferred Site Plans tew"
❑Major Amendment(Subject to Planning Commission Review)=$270 ['Minor Amendment(alterations to parking,circulation,
17 folded copies of plan are required building size,location)=$95
8 folded copies of sketch plan are required
❑Reinstate Plan Review After 10 day Denial=$200 ❑Reinstate Plan After Site Review Denial or Suspension=$65
❑Reinstate Plan Deferred by Applicant
❑To a specific date=$35
❑Indefinitely=$75
17 folded copies of plan are required
Groundwater Assessment (Required for'all non-residential site plans not serviced by public water) -
Was a Groundwater Assessment conducted for the existing site plan?
❑YES
❑NO
If NO and the new plans show a use less than 2,000 gallons per day ❑ Tier 3 Groundwater Review=$400
If NO and the new plans show a use greater than 2,000 gallons per day ❑ Tier 4 Groundwater Review=$1,000
If YES and the use goes from less than to more than 2,000 gallons per day ❑ Tier 4-Tier 3=$400
If YES and the use does not change from less than to more than 2,000 gallons per day ❑ No fee
❑Relief from conditions of approval from Planning Commission or landscape waiver by agent=$180
❑Extension of approval prior to expiration of an approved plan=$45
❑Rehearing of Site Development Plan by the Planning Commission or Board of Supervisors=$190
❑Appeal of Site Development Plan to the Board of Supervisors=$240
Project Name: NGIC MINOR SITE PLAN AMENDMENT
Tax map and parcel: TMP 33-1 D; 33-1 F Magisterial District: Rivanna Zoning:•
CO
Physical Street Address(if assigned): n/a
Location of property(landmarks,intersections,or other): East side of Rte 29N, extension of Boulders Rd.
Contact Person(Who should we call/write concerning this project?): COLLINS ENGINEERING - attn. Scott Collins
Address 800.E. Jefferson St. City Charlottesville State VA zip 22902
Daytime Phone(434) 293-3719 Fax#(434) 293-3719 E-mail scott@collins-engineering.com
Owner of Record Next Generation LLC
Address PO Box 5548 City Charlottesville State VA zip 22905
Daytime Phone(434) 975-3334 Fax# 434 1975-0267 E-mail
Applicant(Who is the Contact person representing?): United Land Corporation
Address PO.Box 5548 City Charlottesville State VA Zip 22905
Daytime Phone( ) Fax#( ) E-mail
FOR OFFICE USE ONLY / SDP#X 6 /�/ 7 �j`7 (Fee Amount$� v Date Paid1/h//(9l who? C £ t( p �%✓l�Receipt# / '(J / �Ck# iS? By.
County of Albemarle Department of Community Development
401 McIntire Road Charlottesville,VA 22902 Voice: (434)296-5832 Fax: (434) 972-4126
11//19/07 Page 1 of2
•Iniynded use or justification filmiest: .
amendment to SDP-2007-138 revising location of building#2&addition of 2nd basement to building#2. Grading and SWM changes necessary to accommodate
tHs change. •
NOTE: WPO AMENDMENT HAS BEEN APPROVED FOR REVISED SWM&E&S MEASURES REFLECTIVE OF THESE PLANS.
•
•
•
Owner/Applicant Must Read and Sign
•
This site plan as submitted contains all of the information required by Section 32.5 (Preliminary Plan)or Section 32.6 (Final
Plan)of the Albemarle County Zoning Ordinance. I understand that plans which lack inforniatiori required by said sections
shall be deemed incomplete and shall be denied by the agent within ten(10)days of sub'mittal"i s provided in Section 32.4.2.1
or Section 32.4.3.3 as the case may be.
For Final 'lans Only: To the best of my knowledge,I have complied with Section 32.4.3.1 and4obtaine'd-tentative approvals
for all a..licable conditions from the appropriate agencies.
7/_ ///0
ature of Owner,Contract Purchaser,Agent . Date
Print Name Daytime phone number of Signatory
11//19/07 Page 2 of 2
SDP#: File Name:
0 32.5.6 The preliminary site plan shall contain the following information:
❑a. The name of the development; names of the owner,developer and individual who prepared the plan; tax map and parcel number;(zoning;
descriptions of all variances, zoning proffers and bonus factors applicable to the site; magisterial distric; county and state; north point;
scale; one datum reference for elevation (where section 30.3, flood hazard overlay district, is involved, United States Geological Survey
vertical datum shall be shown and/or correlated to plan topography);the source of the topography; the source of the survey;sheet num er,
and total number of sheets/date of drawing;date and description of latest revision;owner,zoning,tax map and parcel number and present
sego jacent parcels; departing lot lines; minimum setback lines,yard and building separation requirements; a vicinity sketch showing
the property and its relationship with adjoining streets,subdivisions and other landmarks;and boundary dimensions.
❑b. Written schedules or data as necessary to demonstrate that the site can accommodate the proposed use, including: proposed uses and
maximum acreage occupied by each use; maximum number of dwelling units by type; gross residential density; square footage of
recreation area, percent and acreage of open space; maximum square footage for commercial and industrial uses; maximum number of
employees; maximum floor area ratio and lot coverage if industrial; maximum height of all structures; schedule of parking including
maximum amount required and amount provided; and maximum amount of impervious cover on the site; if a landscape plan is required,
maximum amount of paved parking and vehicular circulation areas.
❑c. If phasing is planned,phase lines and proposed timing of development.
❑d. Existing topography(up to twenty[20]percent slope,maximum five[5] foot contours,over twenty[20]percent slope,maximum ten[10]
foot contours). Proposed grading (maximum five [5] foot contours) supplemented where necessary by spot elevations; areas of the site
where existing slopes are twenty-five(25)percent or greater. Existing topography for the entire site with sufficient offsite topography to
describe prominent and pertinent offsite features and physical characteristics, but in no case less than fifty (50) feet outside of the site
unless otherwise approved by the agent.
❑e. Existing landscape features as described in section 32.7.9.4.c.
❑f. The name and location of all watercourses and other bodies of water adjacent to or on the site. Indicate if the site is located within a
reservoir watershed.
❑g. Location of septic setback lines from watercourses including intermittent streams and other bodies of water.
❑h. One hundred year flood plain limits as shown on the official flood insurance maps for Albemarle County.
❑i. Existing and proposed streets, access easements and travelways, together with street names, state route numbers, right-of-way lines and
widths,centerline radii,and pavement widths.
❑j. Location and size of: existing water and sanitary sewer facilities and easements; storm sewer facilities, drainage channels; and drainage
easements.
❑k. Proposed conceptual lay-out for water and sanitary sewer facilities and storm drainage facilities including storm detention ponds or
structures,indicating direction of flow in all pipes and watercourses with arrows.
❑1. Location of other existing and proposed utilities and utility easements.
❑m. Location of existing and proposed ingress to and egress from the property, showing the distance to the centerline of the nearest existing
street intersection.
❑n. Location and dimensions of all existing and proposed improvements including: buildings (maximum footprint and height) and other
structures; walkways; fences; walls; trash containers; outdoor lighting; landscaped areas and open space; recreational areas and facilities;
parking lots and other paved areas; loading and service areas together with the proposed paving material types for all walks, parking lots
and driveways;and signs.
❑o. All areas intended to be dedicated or reserved for public use.
❑p. Landscape plan in conformance with section 32.7.9 if required.
❑q. Where deemed appropriate by the agent due to the intensity of development, estimated traffic generation figures for the site based upon
current Virginia Department of Transportation rates. Indicate the estimated vehicles per day and direction of travel for all connections to a
public road.
❑r. The preliminary site plan shall be dimensioned to at least the following standards for accuracy:
❑ 1. Boundary,setback and zoning lines-one foot in one thousand(1:1,000)feet;
❑2. Existing contours-one-half('Y2)of the contour interval required in section 32.5.6.d above;
❑3. Proposed contours-within five(5)feet horizontally and vertically;
❑4. Existing structures,utilities and other topographic features-within five(5)feet;
❑5. Proposed structures,roads,parking lots and other improvements-within five(5)feet.
❑s. The agent or the commission may require additional information to be shown on the preliminary site plan as deemed necessary in order to
provide sufficient information for the agent or the commission to adequately review a the preliminary site plan.
32.6 FINAL SITE PLAN CONTENT
U 32.6.1 A final site plan together with amendments thereto shall be prepared and sealed,signed and dated by an architect,professional engineer,
land surveyor,or certified landscape architect,each of whom shall be licensed to practice in the Commonwealth of Virginia.
U 32.6.2 A final site plan shall be prepared on mylar,sepia or other such transparency material which shall be termed as the master drawing.Two
(2)clearly legible blue or black line copies of the master drawing shall be submitted to the department of planning and community development.
(Added 5-1-87) In addition,if review is required by the commission,one(1)reduced copy no larger than eleven(11)inches by seventeen(17)
inches in size shall be submitted.
U 32.6.3 Two(2)copies of a landscape plan shall be submitted with the final site plan if not previously submitted.
U 32.6.4 When the site plan is ready for final approval,the full-sized revised master drawing and a transparency copy of the master drawing shall
be submitted for the agent's signature. Once the agent has signed the master drawing,he shall return the master drawing to the developer and
the developer shall submit four(4)print copies of the signed master drawing to the agent.
U 32.6.5 Unless otherwise approved by the agent,the final site plan shall be prepared to the scale of one(1)inch equals twenty(20)feet or larger
or to such a scale as may be approve( ie agent in a particular case;no sheet shall excec ty-six(36)inches by forty-two(42)inches in
size.The site plan may be prepared o:. (1)or more sheets. If prepared on more than one,.)aheet,match lines shall clearly indicate where
the sheets join.The top of the sheet shall be approximately either north or east.
U 32.6.6 The final site plan shall reflect conditions of approval of the preliminary site plan. The final site plan shall contain the following
information in addition to all the information required on the preliminary site plan:
O a. Specific written schedules or notes as necessary to demonstrate that the requirements of this chapter are being satisfied. In
addition to preliminary site plan information,indicate if sale or rental units;number of bedrooms per unit,and number of units per building
ifmulti-family;specifications for recreational facilities.
U b. Proposed grading(up to twenty[20]percent slope,maximum two[2] foot contours; over twenty[20]percent slope,maximum five[5]
foot contours).
❑ c. Detailed plans for proposed water and sanitary sewer facilities, including: all pipe sizes, types and grades; proposed connections to
existing or proposed central systems; location and dimensions of proposed easements and whether the same are to be publicly or privately
maintained; profiles and cross sections of all water and sewer lines including clearance where lines cross; all water main locations and
sizes; valves and fire hydrant locations; all sanitary sewer appurtenances by type and number; the station on the plan to conform to the
station shown on the profile and indicate the top and invert elevation of each structure.
❑ d.Detailed construction drainage and grading plans:
U 1. Profiles of all ditches and channels whether proposed or existing, showing: existing and proposed grades, and invert of ditches,
cross pipes or utilities;typical channel cross sections for new construction;and actual cross sections for existing channels intended to
remain;
❑ 2.Profiles of all storm sewer systems showing existing and proposed grades;
U 3. Plan view of all drainage systems with all structures,pipes and channels numbered or lettered on the plan and profile views. Show
sufficient dimensions and bench marks to allow field stake out of all proposed work from the boundary lines;
U 4.A drainage summary table for culverts,storm sewer and channels as described in the following example:
Structure Description Length Invert
Number In Slop Remarks
e
42"RCP 50' 424.5 100. Provide
Class III 0 00% 2,EW
2 DI-3B L=8 426.0 - IS-1
0 Top
3 PG-2A 400' 420.0 5.00 D=12"
0
4 Grade Swale 200' 420.0 2.50 D=18"
0
U 5.A legend showing all symbols and abbreviations used on the plan;
❑ 6.General notes,typical sections,and details of all items not covered by Virginia Department of Transportation standard drawings;
U 7. Flood plain limits for the one hundred year storm for all watercourses with an upstream drainage area of fifty(50) acres or more
provided that the county engineer may waive this requirement for drainage areas of less than one hundred (100) acres upon
determination that such information is unnecessary for review of the proposed development.
❑ e.Typical street sections together with specific street sections where street cut or fill is five(5)feet or greater; centerline curve data;radius of
curb returns or edge of pavement;location,type and size of proposed ingress to and egress from the site;together with culvert size;symmetrical
transition of pavement at intersection with existing street; the edge of street surface or face of curb for full length of proposed street; when
proposed streets intersect with or adjoin existing streets or travel-ways, both edges of existing pavement or travelway together with curb and
gutter indicated for a minimum of one hundred(100)feet or the length of connection,whichever is the greater distance.
❑ f.Signature panel for department of planning and community development.
❑ g. For all parking and loading areas, indicate: size; angle of stalls; width of aisles and specific number of spaces required and provided, and
method of computation.Indicate type of surfacing for all paved or gravel areas.
U h.The final site development plan shall be dimensioned to at least the following standards for accuracy:
❑ I.Boundary,setback and zoning lines-nearest one-one hundredth(0.01)of a foot;
U 2.Existing contours-one-half(1/2)of the contour interval required in section 32.6.6.b above;
❑ 3.Proposed contours-within one(1)foot horizontally and vertically;
U 4.Spot elevations-within one-tenth(0.10)of a foot;
U 5. Existing structures,utilities and other topographic features-within two(2)feet. For critical structures,accuracy should be within one-
tenth(0.10)of a foot;
U 6.Proposed structures,roads,parking lots and other improvements-within one hundredth(0.01)of a foot.
❑ i.Landscape plan in conformance with section 32.7.9.
❑ j. Outdoor lighting information including a photometric plan and location, description, and photograph or diagram of each type of outdoor
luminaire.