Loading...
HomeMy WebLinkAboutARB201900146 Architectural Drawings 2020-04-29 (2)CLOSED C FOAM IN! (R-10 MI1\ CONC. FU SEE STRU, 15 MIL. V, BARRIER POROUS[ STRUCT. PREFINISHED AND PREFABRICATED .050 ALUM. COPING +32'-8" TOP OF PARAPET Oro ALUMINUM / COMPOSITE PANEL / SYSTEM / / I / I VARIES / J.B.E. / / I � I � I � I � I I I � I � I FIBER CEMENT RAINSCREEN SYSTEM - 1 (FC-1) NICHIHA VINTAGE 1 WOOD \ FIBER CEMENT \ RAINSCREEN SYSTEM - \ (FC-2) NICHIHA \ ILLUMINATION \ L (SMOOTH) LIGHT BEIGE \ ALUMINUM SUNSHADE, \ BY SAME \ MANUFACTURER AS i STOREFRONT/CURTAIN i WALL SYSTEM +9'-0" i R.O. i ALUMINUM / STOREFRONT SYSTEM / W/ 1" INSULATED / GLAZING / FIBER CEMENT / RAINSCREEN SYSTEM - / (FC-4) NICHIHA / �— — — — — — — ILLUMINATION / (SMOOTH) DARK BEIGE / +2'-8" A.F.F. / R.O. +15'-4" SECOND FINISHED FLOOR STL. BEAM W/ STL. BRACING, SEE STRUCT. FIBER CEMENT RAINSCREEN SYSTEM - (FC-5) NICHIHA RIBBED DARK BEIGE FIBER CEMENT RAINSCREEN SYSTEM - (FC-2) NICHIHA ILLUMINATION (SMOOTH) LIGHT BEIGE ALUMINUM SUNSHADE, BY SAME MANUFACTURER AS STOREFRONT/CURTAIN WALL SYSTEM +9'-0" R.O. I / I / I / I / I / I ALUMINUM / STOREFRONT SYSTEM W/ 1" INSULATED GLAZING I I +2'-8" A.F.F. R.O. FIBER CEMENT RAINSCREEN SYSTEM - (FC-1) NICHIHA VINTAGE WOOD 2" RIGID OR SPRAY FOAM INSULATION (R-10 MIN.) +0'-0" 1 FIRST FINISHED FLOOR 2" 'Z' GIRTS @ 16" O.C. MAX., GALVANIZED - 16 GA. MIN. (HORIZONTAL) ALUMINUM \ COMPOSITE PANEL \ SYSTEM \ -3'-8" B.F.F. / BOTTOM OF / ACM/R.O. / ALUMINUM STOREFRONT SYSTEM / F_ W/O GLAZING, PROVIDE ALL CLOSURE CAPS/TRIM PRECAST CONCRETE PANEL � I 4-8" B.F.F. TOP OF PRECAST/ \\ R.O. \\ I \ I \ I STONE VENEER, MORTAR SCRATCH COAT AND SETTING BED FINISHED GRADE, SEE CIVIL CONC. RETAINING WALL, SEE STRUCT. -11'-0" PARKING LEVEL BITUMINOUS DAMPROOFING, BOTH SIDES OF RETAINING WALL AND TOP OF FOOTING CONC. FOOTING, SEE STRUCT. TYPICAL WALL SECTION ON IVY ROAD i /ALUMINUM � STOREFRONT SYSTEM W/ 1" INSULATED \ GLAZING \ .050 ALUM. PAN \ FLASHING PRE -FINISHED \ TO MATCH STOREFRONT \\ FIBER CEMENT \ RAINSCREEN SYSTEM - \ (FC-4) NICHIHA \ ILLUMINATION 1 (SMOOTH) DARK BEIGE FIBER CEMENT JAMB BEYOND - (FC-1) NICHIHA / VINTAGE WOOD / FIBER CEMENT / .......... RAINSCREEN SYSTEM - / (FC-5) NICHIHA RIBBED / DARK BEIGE / i i i FIBER CEMENT \ RAINSCREEN SYSTEM - \ (FC-5) NICHIHA RIBBED \ DARK BEIGE \ 3" \ FIBER CEMENT JAMB \ BEYOND - (FC-1) NICHIHA \ VINTAGE WOOD \ FIBER CEMENT RAINSCREEN SYSTEM - (FC-2) NICHIHA ILLUMINATION _t (SMOOTH) LIGHT BEIGE .050 ALUM. THRU WALL FLASHING PRE -FINISHED TO MATCH STOREFRONT ALUMINUM I STOREFRONT SYSTEM / W/ 1" INSULATED / GLAZING / ALUMINUM SUNSHADE, / BY SAME / MANUFACTURER AS / STOREFRONT/CURTAIN / WALL SYSTEM / i i i :Z11 ALUMINUM STOREFRONT SYSTEM W/ 1" INSULATED GLAZING FIBER CEMENT JAMB BEYOND - (FC-1) NICHIHA VINTAGE WOOD .050 ALUM. PAN FLASHING PRE -FINISHED TO MATCH (FC-1) 1 FIBER CEMENT RAINSCREEN SYSTEM - (FC-1) NICHIHA VINTAGE WOOD I BEAVER CREEK MEDICAL OFFICE CONT. BACKER ROD AND SEALANT BUILDING Charlottesville, Virginia April 17, zuzu 3 1/2" M FIBER CEMENT RAINSCREEN SYSTEM, PREFABRICATED FACTORY OUTSIDE CORNER - (FC-1) NICHIHA VINTAGE WOOD ALUMINUM STOREFRONT SYSTEM W/ 1" INSULATED GLAZING TYP. STOREFRONT JAMB 1 DETAIL @ FIBER CEMENT CONT. BACKER ROD AND SEALANT 3 1/2' C� FIBER CEMENT RAINSCREEN SYSTEM, PREFABRICATED FACTORY OUTSIDE CORNER - (FC-1) / NICHIHA VINTAGE WOOD FIBER CEMENT RAINSCREEN SYSTEM, SMOOTH/RIBBED - SEE ELEVATION (FC-2, FC-4 OR FC-5) TYP. FIBER CEMENT 2 DETAIL @ TRANSITION