HomeMy WebLinkAboutSDP201700055 Review Comments Final Site Plan and Comps. 2017-11-18
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832
November 18, 2017
Stephen Waller
8159 Cancun Court
Gainsville, VA 20155
RE: SDP201700055 – Verizon – Shadwell (Easton Property) – Tier II PWSF
Dear Mr. Waller,
Comments for the following divisions of the Department of Community Development and other agencies,
as applicable, are provided below:
Planning Department - Christopher Perez
1. [5.1.40(b)(6)] Screening and Siting to Minimize Visibility. Based upon the balloon test conducted
on October 31, 2017 the siting of the proposed facility does not minimize visibility for continuous
durations along Rte. 250, which is an Entrance Corridor (EC). This is not in keeping with the
County’s PWSF policy. The balloon appeared to be 20 + feet above the tree line for a continuous
duration along Rte. 250 (approximately 1,260 feet on Rte. 250 West of the property). From these
vantage points, the balloon was sky-lit and lacked screening for the uppermost portion of the
facility. The balloon was also visible but to a lesser degree for 1,290 feet on Rte. 250 East of the
property. The ARB staff report also makes note of these findings. The item will be heard at the
November 20th ARB meeting.
In order to aid the agent in making a determination I request photographs from the balloon test
and photographic simulations from all views along Rte. 250 discussed above. The visibility of the
facility was acceptable from the various locations staff viewed the facility from, except the views
from Rte. 250 as discussed above.
2. [5.1.40(a)(6)] Photographing balloon test. Provide photos from the balloon test for staff
consideration from all views along Rte. 250 as discussed above. Please identify the camera type,
film size, and focal length of the lens for each photograph.
3. [5.1.40(a)(9)] Photographic simulations. Provide photo simulations of the proposed facility from
all views along Rte. 250 as discussed above.
4. [5.1.40(a)(4)(g), 5.1.40(c)(3)] Setbacks, parking, fencing, and landscaping. All existing and
proposed setbacks, parking, fencing, and landscaping. No setback information is provided on the
plan. Label, dimension, and depict all applicable setbacks on the plan. I have copied the setbacks
provisions for you and provided them below:
Rural Areas - 75 feet Front. 25 feet Side. 35 feet Rear.
Fall Zone - A zone on the surface of the ground that is a circle whose center is the
proposed personal wireless service facility (the “facility”), where the radius is
measured from the outer surface of the facility’s pole or other vertical structure
immediately above its foundation, and where the radius is: (i) for facilities, equal to the
height of the facility.
5. [5.1.40(C)(6), 32.5.2, 21.7(C)] Tax Map Parcel & Zoning. The access road serving the site is
located on TMP 79A1-C-16. VDOT is requiring entrance upgrades (see attached VDOT
comment letter dated 10-26-17). Provide the entrance upgrade detail/cutsheet in the plan and
depict its area of disturbance on the plan.
Other than the entrance upgrade, will any additional site work take place on TMP 79A1-C-16
(specifically outside of the existing gravel driveway)? If so, label and depict its location on the
plan. If that work is in the area of the shared boundary line between TMP 79A1-C-13 and TMP
79A1-C-16 then you will need to request a special exception to the Section 21.7(C) Buffer zone
adjacent to residential and rural areas district. As no construction activity including grading or
clearing of vegetation shall occur closer than twenty (20) feet to any residential or rural areas
district. Special Exception provisions are contained in Section 33.5 and 33.8. There is no
application form. There is a fee of $457 for review of this special exception request.
6. [5.1.40(b)(2)(c), 5.1.40(a)(12)] Projection. A special exception was requested to modify Section
5.1.40(b)(2)(c) of the Zoning Ordinance, particularly the requirement that “in no case shall the
closest point of the back of the antenna be more than twelve (12) inches from the facility”. The
closest point of the back of the antennas will be approximately 16.1875 inches from the face of
the monopole. Staff has no objection to this request and will begin processing the SE for
action by the Board of Supervisor when a resubmittal is received addressing the comments.
The agent recommends the applicant request deferral till the requested items have been
submitted. This project is on a 150-day shot clock, in which an action shall be taken no later
than February 22, 2018.
7. [5.1.40(a)(4)(e)] Topography. Label contours in intervals not to exceed ten (10) feet on Sheet C-
1B.
8. [5.1.40(b)(1)(b)] Outdoor Lighting. An outdoor LED floodlight was mentioned in the narrative as
being on the H-frame, but was not shown on the plan. Depict and label this light location on the
plan and provide a cut sheet for the fixture. Also, on the plans provide the note: “Use of the
outdoor lighting shall be permitted only during maintenance periods.”
Virginia Department of Transportation (VDOT) – Adam Moore
1. Please see letter dated 10-26-2017 for information regarding entrance design standards required for this
proposal.
2. [5.1.40(c)(3)] Setbacks. VDOT does not have a concern about the fall zone being within or across the
Interstate 64 right-of-way.
ARB - Heather McMahon
ARB comments will be available after the Monday, November 20, 2017 ARB meeting.
Engineering – Frank Pohl
1. If the proposed land disturbance is over 10,000 SF threshold then a VSMP permit is required prior to a
building permit being issues.
E911 - Elise Kiewra
No objection
Building Inspections – Michael Dellinger
No objection
ACSA – Alex Morrison
No objection
Fire and Rescue – Shawn Maddox
No objection
Please contact Christopher P. Perez in the Planning Division by using cperez@albemarle.org or 434-
296-5832 ext. 3443 for further information.