Loading...
HomeMy WebLinkAboutSDP202000015 Plan - Revision Minor Amendment 2020-05-20RIVANNA WATER & SEWER AUTHORITYCHARLOTTESVILLE, VIRGINIAVICINITY MAPMOORES CREEK ADVANCEDWATER RESOURCERECOVERY FACILITYMOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITYENGINEERING BUILDING ADDITIONMAY 2020HAZEN AND SAWYER4011 WESTCHASE BLVD, SUITE 500RALEIGH, NORTH CAROLINA 28217CERTIFICATE OF AUTHORIZATION NUMBER: 2771SDP2020-15 - MINOR AMENDMENTSHEET INDEXC1LOCATION MAPC001GENERAL NOTES AND LEGENDC101EXISTING CONDITIONS AND DEMOLITION PLANC103GRADING AND DRAINAGE PLANC104UTILITY PLANC105LANDSCAPING PLANDC1CIVIL DETAILS - SHEET 1DC2CIVIL DETAILS - SHEET 2E10PHOTOMETRIC PLANE11LIGHTING CUT SHEETSDEPARTMENT OF PLANNING AND COMMUNITYDEVELOPMENT SIGNATURE PANEL:1 100YR100YR100YR100YR100YR100YR100YR100YR100YR100YR100YR100YR 100Y R 100YR100YR1 0 0 Y R 100YR100YR 100YR 100YR100YR100YR100YR100YR100YR100YR100YR100YR100YR 100YR100YR100YR100YR100YR 100YR100YR 100YR100YR100YR100 Y R 100YR 100YR100YR100YR100YR100YR 100YR 100YR10 0 Y R 100YR 10 0 Y R 100 Y R 100YR100YR100YR 100YR 100YR 10 0 Y R 100YR 100YR100YR100YR100YR100YR100YR100YR100YRA. MARCH A. MARCH C1 CIVIL LOCATION MAPB. EDWARDS PLOT DATE: 5/20/2020 1:47 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\C1 Saved by CMCNICOL Save date: 3/27/2020 1:27 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 PARCEL NO.: 07700-00-00-038B0 TAX MAP: 77-38B DB: 768, PG: 277 ZONING: LIGHT INDUSTRY 51.71 AC TAX MAP 78, PARCEL 22A DB: 639, PG: 193 ZONING: LIGHT INDUSTRY 21.98 AC 100-YEAR FLOODPLAIN, TYP 100' STREAM BUFFER (WATER PROTECTION ORDINANCE ZONE) PARCEL BOUNDARY, TYP. PROJECT AREA INTERS T A T E 6 4 C O R R I D O R R I V A N N A R I V E R MOORES CREEK CITY OF CHARLOTTESVILLE BF E : 3 2 4 F T .BFE: 324 FT.B F E : 3 2 4 F T . BF E : 3 2 6 . 2 F T . SCALE: 1" = 200' PLAN 0 200'100 SCALE: 1" = 200' 200 NEIGHBORING PARCELS NO.OWNER TAX MAP PARCEL NO DB-PG ZONING USE 1 BLACKBIRD OF CHARLOTTESVILLE LLC 77 20A 5111 - 166 LIGHT INDUSTRY OPEN 2 FRANKLIN STREET LAND TRUST III 77 20 5125-573 RURAL OPEN 3 FALLS, JOHN HARVEY OR VIRGINIA S.77 21A 700-314 LIGHT INDUSTRY INDUSTRIAL 4 RIVANNA WATER AND SEWER AUTHORITY 77 21 3594-660 LIGHT INDUSTRY INDUSTRIAL 5 ELEMENTAL ECOTECH LLC 77 40B 495-325 LIGHT INDUSTRY OPEN 6 RIVANNA WATER AND SEWER AUTHORITY 77 40A 768-277 LIGHT INDUSTRY PUBLIC 7 WOOLEN MILLS 78 21B 639-193 C1 COMMERCIAL COMMERCIAL 8 PIRAEUS LLC 78 30 2639-110 RURAL FOREST 1 2 3 4 5 6 7 8 FLOODWAY, TYP PROPOSED USE:INDUSTRIAL (UTILITY) OWNER:RIVANNA WATER & SEWER AUTHORITY PROPERTY:MOORES CREEK WASTEWATER TREATMENT PLANT PROPERTY SIZE:89.46 ACRES PROPERTY INFO: ZONING:LI (LIGHT INDUSTRIAL); ENTRANCE CORRIDOR (EC) COUNTY:ALBEMARLE STATE:VIRGINIA MAGISTERIAL DISTRICT:SCOTTSVILLE DISTRICT ENGINEER:HAZEN AND SAWYER 4011 WESTCHASE BLVD SUITE 500 RALEIGH NC 27607 SURVEY:DRAPER ADEN ASSOCIATES 110 AVON STREET CHARLOTTESVILLE, VA 22902 434-295-0700 OCTOBER 10, 2019 DATUM:HORZ: NAD83 VIRGINIA SOUTH ZONE VERT: NAVD88 THIS SITE IS NOT LOCATED WITHIN THE WATERSHED OF A PUBLIC WATER SUPPLY RESERVOIR. 100 YEAR FLOODPLAIN ELEVATION: 324.00' REFERENCE: FEMA MAP # 51003C0289D, EFFECTIVE 2/4/2005 AND LOMR 16-03-1107P, EFFECTIVE 2/6/2017. WAIVERS FOR DETENTION, TRAVELWAY WIDTH AND LANDSCAPE PLAN REQUIREMENTS HAVE BEEN GRANTED UNDER THE MAJOR AMENDMENT REVIEW OF SDP200800100. SETBACKS (MET OR N/A) FRONT MINIMUM:10' FROM THE R-O-W OR EXTERIOR EDGE OF SIDEWALK IF SIDEWALK IS OUTSIDE OF R-O-W FRONT MAXIMUM:NONE SIDE AND REAR MINIMUM:50' BETWEEN PUBLIC R-O-W, RURAL AREAS, OR THE MONTICELLO HISTORIC DISTRICT AND STRUCTURE; 30' BETWEEN OFF-STREET PARKING AND THE DISTRICT BOUNDARY. SIDE AND REAR MAXIMUM:NONE PROJECT AREA PARKING REQUIREMENTS: 1 SPACE PER EMPLOYEE AT PEAK SHIFT AND MINIMUM OF 2 VISITOR SPACES REQUIRED PARKING CALCULATION: 14 EMPLOYEES (PEAK SHIFT) + 2 VISITOR SPACES = 16 SPACES PARKING PROVIDED: 20 SPACES + 1 VAN-ACCESSIBLE ADA SPACE HEIGHT OF PROPOSED STRUCTURES: OFFICE TRAILER 11' TRAILER ON PIERS 12.2' (FRONT) 22.7' (REAR) TOPOGRAPHY IS THE AREA OF PROPOSED IMPROVEMENTS IS FROM DRAPER ADEN SURVEY. OVERALL SITE TOPOGRAPHY IS FROM BASE FILES FROM PERVIOUS PLANT IMPROVEMENT SURVEYS. BENCHMARKS DESCRIPTION ELEVATION NOTES BM-A 363.80 CHISELED SQUARE ON BACK OF CURB BM-B 369.55 CHISELED SQUARE ON CORNER OF CONC. PAD ROCK OUTLET PROTECTION LEGEND TEL PED POWER POLE SOIL BORING ABBREVIATIONS 302.00 TPFTREE PROTECTION FENCE CONCRETE SIDEWALK CONTOURGRAVEL ROAD BUILDING/STRUCTURE CONCRETE CURB AND GUTTER SPOT ELEVATION PROPERTY LINE CONCRETE PAD/PAVING APPROXIMATE WOODLINE YARD PIPING FENCE (RESET/NEW) EXISTING 300 NEW EXISTINGSF LIMITS OF DISTURBANCE NEW TB20 OP B/M SF TS SILT FENCE SOIL STABILIZATION BLANKETS OUTLET PROTECTION TEMPORARY SEEDING X X EASEMENT SLOPE STABILIZATION MATTING PS PERMANENT SEEDING MANAGED SLOPES SOIL TYPE BOUNDARY 300 302.00 OHE OVERHEAD ELECTRIC LP LIGHT POLE UGE UNDERGROUND ELECTRIC PP POWER POLE G GAS SS SANITARY SEWER W WATER BM BBM A 100-YR FLOODPLAIN 100YR FLOODWAY 100' STREAM BUFFER CHARLOTTESVILLE CITY LIMITS RIVANNA WATER AND SEWER AUTHORITY TAX MAP 77, PARCEL NO 22A DB: 757, PG: 011 ZONING: LIGHT INDUSTRY ASSOCIATED SITE PLANS: SDP20800100 (APPROVED JAN 2009) SITE PLAN SUBMITTAL FOR THE EXPANSION OF MOORES CREEK WWTP WITH REGARDS TO THE NUTRIENT REMOVAL IMPROVEMENT PROJECT. ASSOCIATED SITE PLAN REVISIONS: SDP2010-82 (APPROVED JAN 2011) SITE PLAN SUBMITTAL FOR IMPROVEMENTS TO THE EXISTING MOORES CREEK PUMP STATION AND ITS ASSOCIATED PROPOSED FORCE MAIN. SDP2012-40 (APPROVED OCT 2012) SITE PLAN SUBMITTAL FOR DIGESTER IMPROVEMENTS AT THE EXISTING MOORES CREEK WWTP SDP2013-33 (APPROVED SEPT 2013) SITE PLAN FOR CONSTRUCTION OF NEW RIVANNA PUMP STATION AND INTERCEPTOR TUNNEL. SDP 2015-145 (APPROVED SEPT 2015) MINOR SITE PLAN AMENDMENT FOR ODOR CONTROL IMPROVEMENTS. RIVANNA PUMP STATION CONSTRUCTION, SDP2013-33 DIGESTER IMPROVEMENTS, SDP2012-40 CLARIFIER COVER CONSTRUCTION, SDP2015-145 GRIT REMOVAL FACILITY IMPROVEMENTS, SDP2015-145 SOUTH ODOR CONTROL FACILITY, SDP2015-145 ODOR CONTROL MODIFICATIONS, 2015-145 MOORES CREEK PUMP STATION EXPANSION, SDP2010-82 PLANT ENTRANCE GATE KNOX BOX LOCATION 1 1 REGULATORY REVIEW 05/2020 LMS 1 A. MARCH A. MARCH C001 SITEWORK CIVIL GENERAL NOTES AND LEGENDB. EDWARDS PLOT DATE: 5/20/2020 1:41 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\C001 Saved by CMCNICOL Save date: 5/20/2020 1:39 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 ROCK OUTLET PROTECTION LEGEND TEL PED POWER POLE SYMBOLS SOIL BORING ABBREVIATIONS EOP LOC OHE SS EDGE OF PAVEMENT LIMITS OF CONSTRUCTION OVERHEAD ELECTRIC SANITARY SEWER FOC FIBER OPTIC CABLE W WATER G GAS PROPERTY LINE CENTER LINELPLIGHT POLE UGE UNDERGROUND ELECTRIC PP POWER POLE PL CL 302.00 TPFTREE PROTECTION FENCE CONCRETE SIDEWALK CONTOURGRAVEL ROAD BUILDING/STRUCTURE CONCRETE CURB AND GUTTER SPOT ELEVATION PROPERTY LINE CONCRETE PAD/PAVING APPROXIMATE WOODLINE YARD PIPING FENCE DEMO (RESET/NEW) EXISTING 300 NEW EXISTING NEW EXISTINGSF ROLLED EROSIONRECM CONTROL MATTING LIMITS OF DISTURBANCE NEW 10 (F.E.S.) MANHOLE CURB INLET YARD INLET STORM DRAIN LINE FLARED END SECTION TB20 OP B/M SF TS SILT FENCE SOIL STABILIZATION BLANKETS OUTLET PROTECTION TEMPORARY SEEDING X X EASEMENT SLOPE STABILIZATION MATTING 302.00 300 GENERAL NOTES: 1.SITE INFORMATION HAS BEEN PROVIDED BY SITE SURVEY PREPARED BY DRAPER ADEN ASSOCIATES DATED OCTOBER 10, 2019. 2.HORIZONTAL CONTROL IS REFERENCED TO NAD 83, VIRGINIA SOUTH ZONE, AND VERTICAL CONTROL IS REFERENCED TO NAVD 88. 3.FLOOD PLAIN ELEVATIONS FROM FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) FLOOD INSURANCE RATE MAP FIRM PANEL 0289D MAP NUMBER 51003C0289D DATED FEBRUARY 04, 2005 THE PROJECT IS LOCATED IN ZONE X, AREA OF MINIMAL FLOOD HAZARD. 4.CONTRACTOR SHALL VERIFY FIELD CONDITIONS BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. CONTRACTOR SHALL VERIFY EXISTING ELEVATIONS AND DIMENSIONS WHERE NEW WORK WILL MATCH EXISTING. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION PRIOR TO THE COMMENCEMENT OF WORK. 5.CONTRACTOR SHALL OBTAIN ALL THE NECESSARY PERMITS FROM THE APPROPRIATE AUTHORITIES, DEPARTMENTS, AND/OR AGENCIES HAVING JURISDICTION PRIOR TO COMMENCING WORK. 6.CONTRACTOR SHALL TAKE CARE TO AVOID DAMAGE TO EXISTING PAVEMENT, TREES, VEGETATION, STRUCTURES, AND UTILITIES THAT ARE NOT INDICATED TO BE DEMOLISHED OR REMOVED. ANY DAMAGE TO EXISTING PAVEMENT, TREES, VEGETATION, STRUCTURES, AND UTILITIES NOT INDICATED TO BE DEMOLISHED OR REMOVED SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. 7.UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE SURVEY INFORMATION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THEIR EXACT LOCATION AND TO AVOID DAMAGE TO THEM. THE CONTRACTOR SHALL CONTACT VIRGINIA 811 AT PHONE NUMBER 811 OR 1-800-552-7001 TO REQUEST UNDERGROUND UTILITY LOCATION MARK-OUT AT LEAST THREE (3) WORKING DAYS BUT NO MORE THAN TEN (10) WORKING DAYS PRIOR TO BEGINNING EXCAVATION, INCLUDING SOIL DRILLING. THE CONTRACTOR SHALL ALSO CONTACT AND REQUEST UTILITY LOCATION MARK-OUT FROM BURIED UTILITY OWNERS WITH UTILITIES ON THE PROJECT SITE THAT ARE NOT PARTICIPANTS OF VIRGINIA 811. 8.WHERE PROPOSED WORK IS IN THE VICINITY OF UTILITY POLES, SUCH THAT SUPPORT OF THE POLE(S) WILL BE REQUIRED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE UTILITY OF THE WORK. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE UTILITY FOR SUPPORT OF THE POLE. 9.WHERE OVERHEAD POWER LINES ARE PRESENT, CONTRACTOR MUST CONTACT THE UTILITY PRIOR TO CONSTRUCTION ACTIVITIES TO DETERMINE THE MINIMUM REQUIRED EQUIPMENT CLEARANCE (MEC) DISTANCE BASED UPON LINE STRENGTH. 10.DURING EXCAVATION AND PLACEMENT OF UTILITIES THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SAFETY REGULATIONS AND SHALL SUBMIT TO THE ENGINEER FOR REVIEW SHEET PILING, SHORING AND/OR BRACING DESIGNS AS MAY BE NECESSARY TO COMPLY WITH THESE REGULATIONS. 11.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR DESIGN AND INSTALLATION OF ALL EXCAVATION SUPPORT AT LOCATIONS AS MAY BE SUGGESTED ON CONTRACT DRAWINGS OR FOR THEIR OWN CONVENIENCE. CONTRACTOR SHALL SUBMIT ALL NECESSARY CALCULATIONS, DRAWINGS, ETC. PREPARED BY A PROFESSIONAL ENGINEER REGISTERED IN THE COMMONWEALTH OF VIRGINIA AS MAY BE NECESSARY FOR REVIEW BY THE ENGINEER PRIOR TO INSTALLATION. REQUIREMENTS FOR EXCAVATION SUPPORT DESIGN MAY BE FOUND IN SPECIFICATION SECTION 02200 EARTHWORK, SECTION 3.03. 12.GROUNDWATER FROM ALL DEWATERING OPERATIONS SHALL BE DISCHARGED TO AN ENVIRONMENTALLY ACCEPTABLE LOCATION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, OR AS DIRECTED BY THE ENGINEER. 13.ALL TEMPORARY FACILITIES ARE SUBJECT TO THE SAME HEALTH AND SAFETY REQUIREMENTS AS PERMANENT FACILITIES, AS SPECIFIED IN THE CONTRACT DOCUMENTS AND HEALTH SAFETY PLAN (HASP). 14.THE CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL DEBRIS GENERATED DURING THE PROJECT OFF SITE AT A PROPERLY PERMITTED DISPOSAL FACILITY. 15.CONTRACTOR SHALL MAKE EVERY EFFORT TO SAVE AND MAINTAIN ALL PROPERTY IRONS, MONUMENTS, OTHER PERMANENT POINTS AND LINES OF REFERENCE AND CONSTRUCTION STAKES. A REGISTERED VIRGINIA LAND SURVEYOR AT THE CONTRACTOR'S EXPENSE SHALL REPLACE PROPERTY IRONS, MONUMENTS, AND OTHER PERMANENT POINTS OF REFERENCE DESTROYED BY THE CONTRACTOR. 16.FOR REFERENCE BENCHMARKS, SEE DRAWING C101. TABLE OF EXISTING MONUMENTS NO ELEVATION SHOWN ON A 363.80 C101 B 369.55 C101 17.ALL ACCESSIBLE FEATURES INCLUDING PARKING AND ROUTES MUST COMPLY WITH ICC A177.1-2009. 18.ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISIBLE INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 19.ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. 20.BUILDING PERMITS REQUIRED FOR NEW TRAILER INSTALLATION. SITE INFORMATION PROJECT DESCRIPTION: THE RIVANNA WATER AND SEWER AUTHORITY IS PROPOSING SITE IMPROVEMENTS TO FACILITATE THE EXPANSION OF THE EXISTING ENGINEERING BUILDING OFFICE SPACE. THE OVERALL PROJECT INCLUDES THE ADDITION OF AN OFFICE TRAILER AND AN EXPANSION TO THE EXISTING PARKING AREA. THE SITE IMPROVEMENTS WILL INCLUDE CONCRETE PIERS TO SUPPORT THE PROPOSED ENGINEERING BUILDING, AND A RETAINING WALL AROUND THE PARKING LOT EXPANSION. A CANOPY WILL BE ADDED TO THE WALKWAY BETWEEN THE EXISTING AND PROPOSED ENGINEERING BUILDINGS. THE OFFICE TRAILER WILL BE PROVIDED AND PLACED ON THE PIERS BY OTHERS. ALL OTHER SITE IMPROVEMENTS, INCLUDING UTILITY HOOKUPS AND PIERS, ARE THE RESPONSIBLY OF THE CONTRACTOR UNDER THIS CONTRACT. THIS PROJECT WILL RESULT IN APPROXIMATELY 0.43 ACRES OF DISTURBANCE. EXISTING SITE CONDITIONS: THE PROJECT IS AT THE MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY (MCAWRRF) LOCATED AT 695 MOORES CREEK LANE, CHARLOTTESVILLE VA 22902. THE PROPERTY IS LOCATED IN UNINCORPORATED ALBEMARLE COUNTY. THE PROPOSED TRAILER WILL BE LOCATED DIRECTLY ADJACENT TO THE EXISTING ENGINEERING BUILDING, AND THE PROPOSED PARKING IS AN EXPANSION TO THE EXISTING PARKING LOT. TOPOGRAPHY IN THIS AREA IS GENTLY SLOPED ALONG THE EXISTING INFRASTRUCTURE, RANGING IN ELEVATIONS FROM 365 FT TO 368 FT. IMMEDIATELY SOUTH OF THE ENGINEERING BUILDING AND PARKING LOT GRADE SHARPLY DROPS OFF TO A 2:1 HILLSIDE. THERE ARE A FEW TREES ADJACENT TO THE ENGINEERING BUILDING AND PARKING LOT, AND THE HILLSIDE IS DENSELY WOODED. THE NEAREST BODY OF WATER IS MOORES CREEK, WHICH IS APPROXIMATELY 200 FT DOWNSTREAM FROM THE PROJECT AREA. MOORES CREEK ULTIMATELY DISCHARGES TO THE RIVANNA RIVER. ACCORDING TO THE 2016 TMDL REPORT, MOORES CREEK STREAM SEGMENT IS SEVERELY IMPACTED FOR ITS AQUATIC LIFE USE. SEDIMENT WAS SELECTED AS THE MOST PROBABLE STRESSOR. THE PROJECT IS LOCATED IN ZONE X, AREA OF MINIMAL FLOOD HAZARD. THE MCAWRRF PARCEL IS BOUND TO THE SOUTH BY THE I-64 CORRIDOR. TO THE WEST AND NORTH ARE MULTIPLE OPEN PARCELS, ZONED RURAL AND LIGHT INDUSTRIAL. TO THE NORTHEAST AND EAST ARE TWO ADDITIONAL PARCELS, BOTH OWNED BY RIVANNA WATER AND SEWER AUTHORITY. OFF-SITE AREAS: NO OFFSITE DISTURBANCE IS PROPOSED AS A RESULT OF THIS PROJECT. SOILS: SOIL TYPES FOUND AT THE MCAWRRF SITE WERE IDENTIFIED BASED ON INFORMATION OBTAINED FROM THE UNITED STATES DEPARTMENT OF AGRICULTURE (USDA), NATURAL RESOURCE CONSERVATION SERVICE (NRCS). THE SITE LIMITS OF DISTURBANCE IS COMPOSED OF TWO TYPES OF SOILS, COLVARD FINE SANDY LOAM, 0 TO 2 PERCENT SLOPES (83), AND RABUN CLAY LOAM, 15 TO 25 PERCENT SLOPES (71D). COVARD FINE SANDY LOAM IS IN HYDROLOGIC SOIL GROUP (HSG) A, AND RABUN CLAY LOAM IS IN HSG B. CRITICAL EROSION AREAS: A PORTION OF THE IMPROVEMENTS ARE LOCATED ON 2:1 SLOPES, CLASSIFIED AS MANAGED STEEP SLOPES BY ALBEMARLE COUNTY. TO PREVENT EROSION, ALL DISTURBED STEEP SLOPES WILL BE STABILIZED WITH GRASS COVER AND SOIL STABILIZATION BLANKETS. RETAINING WALLS IN THE MANAGED SLOPES HAVE BEEN LIMITED TO 6' TO CONFORM TO THE ALBEMARLE COUNTY ORDINANCE. EROSION AND SEDIMENT CONTROL MEASURES: TEMPORARY MEASURES: ·SILT FENCE PER STD 3.05 ·TEMPORARY SEEDING PER STD 3.31 PERMANENT MEASURES: ·RIPRAP OUTLET PROTECTION PER STD 3.18 ·SOIL STABILIZATION BLANKETS PER STD 3.36 ·PERMANENT STABILIZATION: AREAS OF THE SITE THAT WILL NOT BE PAVED WILL BE SEEDED AND MULCHED ACCORDING TO THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK REQUIREMENTS. STORMWATER RUNOFF CONSIDERATIONS: QUALITY THE VIRGINIA RUNOFF REDUCTION METHOD (VRRM) SPREADSHEET FOR RE-DEVELOPMENT WAS USED TO DETERMINE THE NUTRIENT REDUCTION REQUIREMENTS. THE PROPOSED PROJECT IS REQUIRED TO REDUCE THE TOTAL PHOSPHORUS LOAD BY 0.21 LBS/YR. TO MEET THIS REQUIREMENT, 0.21 LBS/YR OF PHOSPHORUS WILL BE PURCHASED FROM A NUTRIENT BANK WITHIN JAMES RIVER BASIN. THIS PROJECT AREA IS IN THE 02080204 - JAMES 8 DIGIT HUC, AND PURSIANT TO THE CODE OF VIRGINIA SECTION 62.1-44.15:35 NUTRIENT CREDITS WILL BE PURCHASED FROM A BANK WITHIN THE NEIGHBORING 8 DIGIT HUC (02080203). QUANTITY PEAK FLOW WAS CALCULATED FOR THE PROJECT AREA USING TR-55 METHODOLOGIES. THE PRE-DEVELOPMENT PEAK FLOW FROM THE 2 AND 10-YR 24-HR STORMS ARE 0.8 CFS AND 1.7 CFS, RESPECTIVELY. THE POST-DEVELOPMENT PEAK FLOW FROM THE 2 AND 10-YR 24-HR STORMS ARE 1.2 CFS AND 2.3 CFS, RESPECTIVELY. UNDER PRE-DEVELOPMENT CONDITIONS, RUNOFF FROM THE PROJECT AREA SHEET FLOWS AWAY FROM THE ENGINEERING BUILDING AND PARKING LOT AND DOWN A STEEP HILL. NO CHANGE IN OVERALL DRAINAGE PATTERNS IS PROPOSED POST-DEVELOPMENT. THE INCREASE IN SHEET FLOW FOR THE 2 AND 10-YR 24-HR STORM IS 0.4 CFS AND 0.6 CFS, RESPECTIVELY. AT THE POINT OF OUTFALL THE DRAINAGE AREA OF MOORES CREEK IS APPROCIAMTELY 35.1 SQUARE MILES. GIVEN THE MINIMAL INCREASE IN PEAK FLOW AND THE LARGE DRAINAGE AREA OF MOORES CREEK, THE PROPOSED DEVELOPMENT WILL NOT CONTRIBUTE TO DOWN-GRADIENT EROSION, SEDIMENTATION, OR FLOODING. THE PARKING LOT EXPANSION WILL BE CURBED AND RUNOFF WILL DISCHARGE THROUGH A CURB CUT. A RIPRAP OUTLET PROTECTION PAD HAS BEEN DESIGNED IN ACCORDANCE WITH THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH) TO ENSURE FLOW IS NON-EROSIVE FOR THE 2 AND 10-YEAR STORMS. EROSION AND SEDIMENT CONTROL MAINTENANCE NOTES: IN GENERAL, ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED AFTER EACH RAINFALL OR WEEKLY, WHICHEVER IS MORE FREQUENT, AND SHOULD BE CLEANED AND REPAIRED ACCORDING TO THE FOLLOWING SCHEDULE: 1.EROSION AND SEDIMENT CONTROLS WILL BE CHECKED REGULARLY FOR UNDERMINING OR DETERIORATION AND BUILDUP OR CLOGGING WITH SEDIMENT. CORRECTIVE ACTION SHALL BE TAKEN IMMEDIATELY. 2.FREQUENT INSPECTIONS AND CLEANING OF MUD AND DEBRIS FOUND OUTSIDE OF THE LIMITS OF DISTURBANCE IS REQUIRED, ALONG WITH ANY OTHER REMEDIES REQUIRED BY THE COUNTY. 3.ALL SEEDED AREAS WILL BE CHECKED REGULARLY TO SEE THAT A GOOD STAND OF GRASS IS MAINTAINED. AREAS SHALL BE RESEEDED AS NEEDED. TEMPORARY STABILIZATION WILL BE USED AS REQUIRED BY THE COUNTY. PS PERMANENT SEEDING 11 12 13 MANAGED SLOPES SOIL TYPE BOUNDARY STRUCTURE LIFE SAFETY INFORMATION: 1.PROPOSED OFFICE TRAILER IS 1410 SF. EXISTING OFFICE TRAILERS ARE 3082 SF, FOR A OVERALL OFFICE TRAILER COMPLEX AREA OF 4492 SF. EXISTING STRUCTURES ARE NOT SPRINKLED AND PROPOSED STRUCTURE WILL NOT BE SPRINKLED. 2.PROPOSED TRAILER IS TYPE 5 B UNPROTECTED CONSTRUCTION, OR AS NOTED OTHERWISE BY TRAILER MANUFACTURER. 3.BUILDING OCCUPANCY CLASSIFICATION IS BUSINESS GROUP B. 1 REGULATORY REVIEW 05/2020 LMS 1 1 335 340 345 350 355 360 358 353 348 342 337 332 334 365 366 363 360 355 358 353 350 348 345 343 340 33 9 337 360362 358 355 350 352 348 345 343 341 340 339 3 6 4 3653663673683693703 7 1 36 4 363XXXW UGE UGE W W E W W CO WW W W W W W W W W W W W W W SSWSS NOTES: 1.CONTRACTOR SHALL COORDINATE WITH PLANT STAFF ABOUT RELOCATION OF SPEED LIMIT SIGN. 2.CONTRACTOR SHALL HAVE VIRGINIA LICENSED SURVEYOR ESTABLISH NEW BENCHMARK TO REPLACE BENCHMARK DEMOLISHED IN NEW LOCATION WHICH WILL NOT INTERFERE WITH CONSTRUCTION ACTIVITIES. 3.COMMUNICATIONS STRUCTURE SHALL BE LOCATED OUTSIDE OF PROPOSED PARKING LOT AREA. CONTRACTOR SHALL COORDINATE RELOCATION WITH CENTURY LINK. 4.DEMOLITION OF WOODEN RAMP AND HANDRAIL SHALL BE COORDINATE WITH PLANT STAFF. TIMEFRAME EXISTING ENGINEERING BUILDING IS WITHOUT ADA ACCESS SHALL BE KEPT TO A MINIMUM. 5.THE PROJECT AREA IS OUTSIDE THE 100-YEAR FLOODPLAIN, 100 FT STREAM BUFFER, AND STATE DAM BREAK INUNDATION ZONES. THE PROJECT AREA IS WITHIN THE FEDERAL DAM BREAK INUNDATION ZONE. A. MARCH A. MARCH C101 SITEWORK CIVIL EXISTING CONDITIONS AND DEMOLITION PLANB. EDWARDS PLOT DATE: 5/20/2020 1:42 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\C101 Saved by CMCNICOL Save date: 5/20/2020 11:58 AMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 BENCHMARK A ELEV: 363.80 CHISELED SQUARE ON BACK OF CURB, SEE NOTE 2 REMOVE CONCRETE RAMP REMOVE LANDSCAPING AND TREES (160 SF) RELOCATE HANDICAP SIGN REMOVE PORTION OF ASPHALT PAVEMENT RELOCATE COMM. STRUCTURE, SEE NOTE 3 RELOCATE SIGN, SEE NOTE 1 ENGINEERING BUILDING FFE = 366.20 REMOVE WOODEN RAMP AND HAND RAIL, SEE NOTE 4 0 20'10 SCALE: 1" = 20' 20 SCALE: 1" = 20' PLAN MANAGED SLOPE ELECTRICAL STRUCTURE TO BE MODIFIED, SEE ELECTRICAL PLANS BENCHMARK B ELEV:369.55 CHISELED SQUARE ON CORNER OF CONC. PAD AREA TO BE CLEARED AND GRUBBED, TYP MANAGED SLOPE REMOVE CURB AND GUTTER, TYP TREE REMOVAL REMOVE CONCRETE CURB AND GUTTER REMOVE CONCRETE SIDEWALK TREE REMOVAL TREE REMOVAL INTERNAL PROPERTY LINE PARCEL NO: 07700-00-00-038B0 TAX MAP: 77-38B DB: 768, PG: 277 PARCEL NO: 07700-00-00-022A TAX MAP: 77-38B DB: 768, PG: 277 DEMOLISH ASPHALT PAVEMENT AND CURB AND CUTTER 1 REGULATORY REVIEW 05/2020 LMS 335 340 345 350 355 360 358 353 348 342 337 365 366 363 360 355 358 353 350 348 345 343 340 33 9 360362 358 355 350 352 348 345 343 3 6 4 36536636736836 4 363W W E 365364364366367368 9', TYP 18', TYP11'18'5' 364 R10' LP NOTES: 1.ACCESSIBLE PARKING SPACE AND ACCESS AISLE SHALL BE AS PER THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA). ACCESS SPACES SHALL HAVE PAVEMENT MARKINGS, SIDEWALK ACCESS RAMP AND SIGNAGE. SIGN MUST INCLUDE PHRASE "VAN-ACCESSIBLE." SIGNS SHOULD BE MOUNTED SO THAT THE LOWER EDGE OF THE SIGN IS AT LEAST SEVEN (7) FEET ABOVE THE GROUND. SEE DETAIL 1 ON DC1. 2.CURB RAMP SHALL HAVE A MAXIMUM SLOPE OF 1:12 AND A MAXIMUM CROSS SLOPE OF 1:48. SIDE FLARE MAY HAVE A MAXIMUM SLOPE OF 1:10. PROVIDE A LANDING PAD WITH MINIMUM DIMENSIONS OF 26" X 48" AT TOP OF CURB LAMP. 3.PROVIDE 6" THICK SECTION OF #57 STONE IN AREAS BETWEEN EXISTING AND PROPOSED ENGINEERING BUILDING, DIRECTLY UNDER TRAILER, AND 4' BEYOND TRAILER WALLS ON SOUTH AND EAST SIDES. PROVIDE TYPE II GEOTEXTILE SEPARATOR BENEATH GRAVEL LAYER. 4.CURB AND GUTTER SHALL BE INSTALLED TO ALLOW DRAINAGE THROUGH BACK OF CURB ISLAND TO CURB CUT. 5.PER ALBEMARLE COUNTY CODE 30.7.5.; RETAINING WALLS SHALL BE A MAXIMUM HEIGHT OF 6 FT. MAXIMUM RETAINING WALL HEIGHT AS DESIGNED IS 5.6 FT. A. MARCH A. MARCH C103 SITEWORK CIVIL GRADING AND DRAINAGE PLANB. EDWARDS PLOT DATE: 5/20/2020 1:43 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\C103 Saved by CMCNICOL Save date: 5/20/2020 1:33 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 ENGINEERING BUILDING FFE = 366.20 ENGINEERING BUILDING FFE = 366.20 60' X 23.5' SCALE: 1" = 10' PLAN LANDSCAPING, TYP CURB AND GUTTER, TYP 4' SIDEWALK, TYP ADA CURB RAMP WITH DETECTABLE WARNING STRIP, SEE NOTE 2 RETAINING WALL, HEIGHT VARIES GUARD RAIL 4' CURB CUT WITH RIPRAP OUTLET PROTECTION PAD 0 10'5 SCALE: 1" = 10' 10 ADA PARKING SPACE, SEE NOTE 1 366.20 STAIRS WITH LANDING AND HANDRAIL TO BE PROVIDED BY TRAILER SUPPLIER363.80364.20 3.57% 2.30% 2.63% TIE SIDEWALK INTO EXISTING ELEVATIONS, 1:48 MAXIMUM SLOPE 364.0 4364.0 0 363.9 0 363.8 5 363.90363.94PARKING LOT EXISTING SPACES: 8 PROPOSED: 20 LANDSCAPING ISLAND, SEE NOTE 4 GRADE: 367.00 TW: 367.50 BW: 361.89 GRADE: 366.00 TW: 366.50 BW: 361.62 GRADE: 365.00 TW: 365.50 BW: 363.52 GRADE: 368.40 TW: 368.90 BW: 365.55 TREE LINE, TYP PAVEMENT JUNCTION ASPHALT PAVEMENT0245000 0244503 0242000 0251301 0251000 CONCRETE PIER, TYP, SEE STRUCTURAL DRAWINGS 2 DC1 3 DC1 #57 STONE, SEE NOTE 3 1.91% 368.5 0 368.5 0 368.50 GRADE: 368.00 TW: 368.50 BW: 364.00 CURB AND GUTTER 0242000 R5' CURB AND GUTTER 0242000 INTERNAL PROPERTY LINE, TYP CANOPY TO BE RESTRUCTURED TO ACCOMMODATE PROPOSED TRAILER ALUMINUM LANDING AND ADA RAMP TO BE PROVIDED BY TRAILER SUPPLIER WALL MOUNTED LIGHTING FIXTURE, TYP SEE ELEC DWGS LIGHT POLE, TYP SEE ELEC DWGS 368.4 0R10' ASPHALT PAVEMENT 0251000 1 REGULATORY REVIEW 05/2020 LMS 1 W W UGE UGE UGE UGE W W E CO W W W W W W W W W W W W W W W W W W W W W W W SSW WWSS SS SS 335 340 345 350 355 360 358 353 348 342 337 334 365 363 360 355 358 353 350 348 345 343 340 33 9 337 360362 358 355 350 352 348 345 343 341 340 3 6 4 36536636736836 4 363365364364366367DYHLP NOTES: 1.LOCATION OF 4" SS LINE APPROXIMATE, NOT FROM SURVEY. CONTRACTOR SHALL DETERMINE EXACT LOCATION AND ELEVATION IN FIELD. 2.PROPOSED 4" SS SHALL HAVE A MINIMUM SLOPE OF 1/8" PER FOOT. 3.EXACT LOCATION OF WATER AND SEWER CONNECTION TO BE DETERMINED IN FIELD. ALL ABOVE GROUND WATER PIPING MUST BE HEAT TRACED. 4.LOCATION OF 1" PW LINE APPROXIMATE, NOT FROM SURVEY. CONTRACTOR SHALL DETERMINE EXACT LOCATION AND ELEVATION IN FIELD. IF A CONFLICT EXISTS, 1" PW SHALL BE RE-ROUTED TO AVOID BUILDING PIERS. A. MARCH A. MARCH C104 SITEWORK CIVIL UTILITY PLANB. EDWARDS PLOT DATE: 5/20/2020 1:43 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\C104 Saved by CMCNICOL Save date: 5/20/2020 1:04 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 ENGINEERING BUILDING FFE = 366.20 ENGINEERING BUILDING SCALE: 1" = 10' PLAN 0 10'5 SCALE: 1" = 10' 10 GRINDER PUMP STATION SANITARY SEWER CLEANOUT WYE CONNECTION TO 4" SS AND CLEANOUT, SEE NOTE 3 45° VERTICAL BEND, TRANSITION TO BELOW GRADE PIPING 4" SS, S E E N O T E 1 TEE CONNECTION TO WATER SERVICE PRV AND RPZ FOR TRAILER WATER SERVICE, PROPOSED CONNECTION SHALL BE LOCATED DOWN STREAM OF STRUCTURE NEW TREE LINE, TYP TRAILER CONNECTION, SEE NOTE 3 WATER METER, PROTECT DURING CONSTRUCTION 1" PW, SEE NOTE 4 3" SS CLEANOUT 0260200 0260200 1" PW, COPPER PIPE 4" SS PVC SCH80, SEE NOTE 2 VALVES, PROTECT DURING CONSTRUCTION REPAIR WOODEN RAMP, LANDING, AND CANOPY INTERNAL PROPERTY LINE LIGHT POLE, TYP WALL MOUNTED LIGHTING FIXTURE, TYP FIRE HYDRANT WITH 6" TS&V 6" PW 3 DC2 1 REGULATORY REVIEW 05/2020 LMS 1 1 340 345 350 355 360 358 353 348 342 365 366 363 360 355 358 353 350 348 34 5 360362 358 355 350 352 348 3 6 4 36536636736836936 4 363W E 365364364366367368 364 LANDSCAPING LEGEND DWARF ENGLISH BOX WOOD BURFORD HOLLY RED MAPLE A. MARCH A. MARCH C105 SITEWORK CIVIL LANDSCAPING PLANB. EDWARDS PLOT DATE: 5/20/2020 1:44 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\C105 Saved by CMCNICOL Save date: 5/20/2020 12:45 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 SCALE: 1" = 10' PLAN 0 10'5 SCALE: 1" = 10' 10 SEE LANDSCAPING LEGEND NEW TREELINE NOTES: 1.DIG PLANTING HOLE AT LEAST 2X THE WIDTH OF THE ROOT BALL OR CONTAINER. 2.SCARIFY SUBGRADE AND SIDES OF PLANTINGS HOLE WHEN PLANTING IN CLAY SOIL. 3.SET THE TOP OF THE ROOT BALL LEVEL WITH THE SOIL SURFACE, OR 1-2" ABOVE IF THE SOIL IS PRONE TO SETTLING. 4.IF B&B PLANT, REMOVE BURLAP FROM AT LEAST THE TOP 12 INCHES OF THE ROOT BALL, WITHOUT DISTURBING THE ROOT BALL. REMOVAL ALL CORD FROM THE TRUNK. REMOVE BURLAP AND WIRE BASKET FROM THE ROOT BALL. 5.BACK FILL THE PLANTING HOLE WITH EXCAVATED NATIVE SOIL, BROKEN UP OR TILLED. WATER TO REMOVE AIR POCKETS. DO NOT ADD AMENDMENTS. 6.PLACE MULCH ON THE SURFACE TO A (SETTLED) DEPTH OF 1 TO 3 INCHES. SCALE: NTS 1DETAIL C105 SHRUB PLANTING DETAIL SHRUB PLANTING SCHEDULE TYPE QTY SCIENTIFIC NAME COMMON NAME MATURE PLANT SIZE CONTAINER SIZE HEIGHT AT INSTALLATION SPACING SHRUB 4 BUXUS SEMPERVIRENS "SUFFRUTICOSA" DWARF ENGLISH BOXWOOD 3'-15'3 GAL 18"5' SHRUB 4 IIEX COMUTA "BURFORDII"BURFORD HOLLY 3'-15'3 GAL 18"5' NOTES: 1.ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. D H H H H D D D D ENGINEERING BUILDING SEE LANDSCAPING LEGEND LIGHTPOLE, TYP WALL-MOUNTING LIGHTING FIXTURE, SEE ELEC DWGS H M M M TREE PLANTING SCHEDULE TYPE QTY SCIENTIFIC NAME COMMON NAME MATURE PLANT SIZE CALIPER AT INSTALLATION MED. SHADE TREE 2 ACER RUBRUM & CVS.RED MAPLE 40' - 50'2.5" CALIPER SEE LANDSCAPING LEGEND EX TREE 1 EX TREE 3 8.5" CALIPER EX TREE 4 4" CALIPER 33' 43'30' EX TREE 2 4" CALIPER EX TREE 5 CLUSTER OF TREES 77' 1 REGULATORY REVIEW 05/2020 LMS 1 1 1 1 A. MARCH A. MARCH DC1 STANDARD DETAILS CIVIL CIVIL DETAILS - SHEET 1B. EDWARDS PLOT DATE: 5/20/2020 1:45 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\DC1 Saved by CMCNICOL Save date: 2/13/2020 5:37 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 TYPICAL CONCRETE WALKWAY 4'1/2" EXPANSION JOINTS 48' MAX SPACING BETWEEN 4" THICK CONCRETE WALK TYPICAL CONTRACTION JOINT 0245000 1/2" EXPANSION JOINT MATL REQUIRED WHEN WALK ABUTS RIGID STRUCTURES WHEN WIDTH OF SIDEWALK, PAD, ETC EXCEEDS 6', LONGITUDINAL CONTRACTION JOINTS SHALL BE PLACED AS REQUIRED VARIES, SEE PLAN FOR WIDTH 6" 3" R 6"6"2'-6" CURB AND GUTTER 1 1/2" 0242000 12" MIN BACK OF CURB SLOPE ASPHALT PAVEMENT CONCRETE CURB AND GUTTER FINISHED GRADE NOTES: 1.CONTRACTION JOINTS SHALL BE PLACED AT 10 FOOT INTERVALS, OR 15 FOOT INTERVALS WHEN A MACHINE IS USED TO PLACE THE CURB. 2.EXPANSION JOINTS SHALL BE PLACED AT 90 FOOT INTERVALS AND ADJACENT TO ALL RIGID OBJECTS. NEW ASPHALT PAVEMENT AGGREGATE BASE COURSE TACK COAT CUT BACK EXIST BASE COURSE 12" MIN CUT BACK EXIST TYPICAL PAVEMENT JUNCTION EXIST BASE COURSE 0251301 0251000SEE TACK COAT ASPHALT SURFACE COURSE, 2" MIN ASPHALT BASE COURSE, 3.5" MIN SURFACE COURSE 6" MIN FROM BASE SLOPE EXIST SURFACE COURSE 2'-0"6"MIN 18"2' TYPFINISHED GRADE (VARIES) EMBEDMENT, TYP 3/4" SET, TYP GEOGRID REINFORCEMENT (SEE NOTE 1 AND SPECIFICATION SECTION 13800 - GEOGRID) (SEE NOTE 1) NOTES: 1.GEOGRID REINFORCEMENT MATERIAL AND EMBEDMENT LENGTH TO BE ESTABLISHED BY PROFESSIONAL ENGINEER REGISTERED IN THE COMMONWEALTH OF VIRGINIA BASED UPON CURRENT AND PROJECTED LOADINGS AND PROPER DRAINAGE. MINIMUM GEOGRID LENGTH TO BE 0.75 TIMES THE MAXIMUM WALL HEIGHT AND TO BE UNIFORM FOR ALL LAYERS. 2.WALL BACKFILL MATERIAL USED IN DESIGN SHALL BE ON-SITE MATERIAL OR MATERIAL MATCHING WALL DESIGN PARAMETERS SHALL BE SUPPLIED BY CONTRACTOR AT NO ADDITIONAL COST. IT SHOULD BE ASSUMED BACKFILL MATERIAL IS NOT AVAILABLE ON SITE. SEE SPECIFICATION SECTION 13100 - MSE RETAINING WALLS FOR BACKFILL SPECIFICATIONS. 3.PROVIDE POSITIVE DRAINAGE AWAY FROM BACK OF WALL. 4.INCLUDE SUBGRADE LOADING FOR PARKING AREA WHERE APPLICABLE. DESIGN TO ACCOMODATE H-20 LOADING AS MINIMUM. 8" HIGH MODULAR CONCRETE FACING UNITS 6"Ø PERFORATED DRAINAGE PIPE SLOPE (1/8" PER FT) TO DRAIN SURROUNDED WITH AASHTO NO. 57 STONE. OUTLET PIPE EVERY 25 FT OF WALL LENGTH IMPORTED SELECT GRANULAR BACKFILL (SEE NOTE 2) 12" MIN THICK AASHTO # 57 STONE DRAINAGE FILL IMPERVIOUS FILL, MIN 12" THICK ADHERE CAP UNIT TO TOP UNIT W/ CONCRETE ADHESIVE AS SPECIFIED BY THE MASONRY WALL SUPPLIER AASHTO # 57 OR CLASS B CONCRETE LEVELING PAD 6" THICK x 2'-0" WIDE, CONT. FILTER GEOTEXTILE TOTAL WALL HEIGHT VARIES FINISHED GRADE .(SEE NOTE 3) SCALE: N.T.S. 2DETAIL DC1 DETECTABLE WARNING SURFCE SCALE: N.T.S. 1DETAIL DC1 VAN ACCESSIBLE PARKING SIGNS 4'-0"EQUALEQUAL4'-0"VARIES 12:1 3:13:1 SL O P E 12:1 3:1 S L O P E , M A X CL VARIES - SEE SITE PLAN 0251000 SLOPE AT 1/4:12 SLOPE AT 1/4:1212" MIN TYP TACK COAT NOTE: 2" ASPHALT SURFACE COURSE 3.5" ASPHALT BASE COURSE TYPICAL ROADWAY SECTION CUT SECTION FILL SECTION THE 2" ASPHALT CONCRETE SURFACE COURSE AND THE TACK COAT SHALL NOT BE PLACED UNTIL COMPLETION OF ALL OTHER WORK IN CONTRACT. 8" AGGREGATE BASE COURSE COMPACTED SUB-GRADE TYPE I SEPARATOR GEOTEXTILE SCALE: N.T.S. 3DETAIL DC1 RETAINING WALL 1 REGULATORY REVIEW 05/2020 LMS A. MARCH A. MARCH DC2 STANDARD DETAILS CIVIL CIVIL DETAILS - SHEET 2B. EDWARDS PLOT DATE: 5/20/2020 1:45 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\DC2 Saved by CMCNICOL Save date: 5/20/2020 12:50 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 THE EXCAVATED SOIL. 4. BACKFILL AND COMPACT 4" UPSLOPE ALONG THE LINE OF STAKES 2. EXCAVATE A 4"x4" TRENCH 3' A FLOW 1. SET THE STAKES. AND EXTEND IT INTO THE TRENCH. 3. STAPLE FILTER MATERIAL TO STAKES FLOW FLOW B A (FRONT ELEVATION) DRAINAGEWAY INSTALLATION POINTS A SHOULD BE HIGHER THAN POINT B. (WITHOUT WIRE SUPPORT) CONSTRUCTION OF A SILT FENCE (PERSPECTIVE VIEW) SHEET FLOW INSTALLATION 0227000 SF MAX PIPE OUTLET CONDITIONS SECTION A-A TYPE II SEPARATOR PLAN VIEW odo3d 0 % AREA WITH NO DEFINED CHANNEL PIPE OUTLET TO FLAT * 0243300 *SEE SITE PLAN * OP KEY IN 6"-9"; RECOMMENDED FOR ENTIRE PERIMETER GEOTEXTILE 4' 2' SCALE: N.T.S. 1DETAIL DC2 RAISED HEXAGONAL HEAD THREADED PLUG PVC RISER LOCATE LOCATE CLEAR OF OBSTRUCTIONS WYE OR 45° BENDVARIES CLEANOUT PVC DRAIN FINISH GRADE 0260200 CONCRETE PAD, SEE 0264005 FRONT VIEWSIDE VIEW WARNING SIGN DETAIL DO NOT ENTER TREE PROTECTION AREA TREE PROTECTION AREA DO NOT ENTER NOTE: FOR TREE PROTECTION ONLY NOTES: 1.WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 2.LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE, AND SPACED AS DETAILED. 3.PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. 4.FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 5.ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 6.MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. TREE PROTECTION FENCE GRADE2'-2"3'-0"24"WARNING AND BARRIER FENCE. SEE SPECIFICATION 31 10 00 3' - 4"18"4"3"4"3"4"MIN 12 1/2 GAUGE INTERMEDIATE WIRES, TYP PLASTIC OR WIRE TIES 8'-0" MAX VARIABLE AS DIRECTED BY THE ENGINEER MIN 10 GAUGE LINE WIRES WARNING SIGN WOVEN WIRE FABRIC STEEL POST SCALE: N.T.S. 2DETAIL DC2 GALVANIZED STEEL GUARD RAIL VDOT STANDARD IN ACCORDANCE WITH GUARD RAIL SHALL BE 6'-3" BOLTS 5/8" SPLICE FOR POST BOLT 3/4"x2 1/2" SLOT 0244503 SCALE: N.T.S. 3DETAIL DC2 1 REGULATORY REVIEW 05/2020 LMS XXXXW UGE UGE W W E W W SANITARY MANHOLE TOP=369.60 INV. TO TOP OF FORCEMAIN PIPE = 364.38 CO WW W W W W W W W W W W W W W SSWSS 500YR500YR500YR500YR500YR500YR500YR500YR500YR500YR500YR500YR500YR500YRDYH2.8 4.9 4.6 2.6 1.3 2.8 3.8 3.0 2.2 1.3 2.0 2.7 2.4 1.8 1.0 1.7 2.1 2.5 2.0 1.0 1.8 2.2 2.7 2.2 1.2 2.7 3.4 2.9 2.2 1.2 3.1 3.5 2.5 2.0 1.2 3.0 3.4 2.8 2.3 1.3 2.3 2.7 2.9 2.2 1.2 2.4 2.8 3.2 2.2 1.0 3.0 3.2 3.0 2.1 3.0 2.9 2.6 1.9 3.2 2.7 2.4 1.9 3.1 2.9 2.5 1.8 2.4 2.9 2.7 1.6 2.4 2.9 2.7 1.5 1.9 3.2 3.0 2.5 1.5 2.0 2.9 2.5 2.2 1.4 2.3 2.9 2.2 2.1 1.5 2.2 2.8 2.4 2.0 1.2 1.7 2.1 2.5 1.9 1.1 1.6 2.0 2.3 1.6 0.9 2.1 2.5 2.0 1.3 0.7 1.6 1.8 1.3 1.1 0.6 0.9 1.0 1.0 1.1 0.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.8 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 1.1 2.6 4.5 2.7 1.4 0.8 0.5 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 1.3 0.9 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 1.9 4.1 5.2 3.3 1.8 0.7 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.7 1.9 3.8 3.6 2.7 1.7 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 1.6 2.9 2.7 2.1 1.4 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.3 2.0 2.4 2.3 1.3 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.4 2.1 2.4 2.5 1.5 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.7 3.2 3.0 2.6 1.7 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 2.1 3.7 2.9 2.2 1.5 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 2.3 3.6 3.0 2.5 1.7 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.8 1.9 2.6 2.9 2.6 1.6 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.9 2.0 2.7 3.1 2.7 1.5 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.8 2.3 3.2 3.2 2.5 1.4 0.5 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.7 2.5 3.4 2.8 2.3 1.4 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.7 2.7 3.0 2.4 2.1 1.3 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.9 2.9 3.2 2.6 2.1 1.2 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.1 2.2 2.7 2.9 2.1 1.1 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.2 2.3 2.7 3.0 2.0 0.9 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.1 2.8 3.0 2.8 1.9 0.9 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.1 2.9 2.8 2.5 1.8 0.9 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.4 2.8 2.4 2.2 1.7 0.9 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 1.6 2.9 2.6 2.2 1.7 0.8 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.3 2.0 2.4 2.3 1.4 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.3 1.9 2.2 2.1 1.2 0.5 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 1.4 2.4 2.2 1.7 1.0 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 1.2 2.2 1.6 1.3 0.9 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.7 1.1 1.0 1.1 0.8 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.5 0.7 0.7 0.9 0.7 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.6 0.6 0.7 0.5 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.4 0.5 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 NOTES: 1.PHOTOMETRIC CALCULATIONS PERFORMED INDICATE FOOT-CANDLE LIGHTING LEVELS AT GRADE ACROSS THE NEW PARKING LOTS. T. MANGALAM T. MANGALAM E10 ELECTRICAL SITE PHOTOMETRIC PLANB. PICKETT PLOT DATE: 5/20/2020 2:31 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\ELECTRICAL\E10 Saved by TMANGALAM Save date: 3/16/2020 10:22 AMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 27607 SCALE: 1" = 20' - 0" SITE PHOTOMETRIC PLAN EXISTING ENGINEERING TRAILERS NEW ENGINEERING TRAILER CALCULATION ZONE NO. 1 LL1 LL1 LL1 LL1LW1 LW1 LUMINAIRE SCHEDULE SYMBOL TYPE QUANTITY MANUFACTURER CATALOG #DESCRIPTION LAMP WATTAGE LW1 2 HOLOPHANE HLWPC2P10 40K AS T3M BKDSP HLWPC2, 10 LED'S, 40K CCT, TYPE 3 MEDIUM, FULL CUTOFF, BLACK ALUMINUM HOUSING LED 28 LL1 4 LEOTEK ELECTRONICS GC1-80F-MV-NW-2XX-350 GC1 F-SERIES, 80F LED, 120V, 40K CCT, TYP 2, 350mA DRIVE CURRENT, FULL CUTOFF, GRAY ALUMINUM POLE AND HOUSING LED 85 STATISTICS DESCRIPTION CALC. ZONE AVG. (fc)MAX. (fc)MIN. (fc) UNIFORMITY (AVG/MIN) LLF (Light Loss Factor) COMPLIANCE WITH ALBEMARLE COUNTY PARKING LOTS 1 2.6fc 5.7fc 0.7fc 3.7:1 1.0 YES POLE MOUNTED LIGHT FIXTURE, TYP. WALL-MOUNTED LIGHTING FIXTURE, TYP. 1 A. MARCH A. MARCH E11 ELECTRICAL LIGHTING CUT SHEETSB. EDWARDS PLOT DATE: 5/20/2020 1:47 PM BY: CMCNICOLFile: O:\31442-RAL\31442-002\CAD_BIM\CIVIL\E11 Saved by CMCNICOL Save date: 3/18/2020 1:38 PMPRELIMINARY DRAWING DO NOT USE FOR CONSTRUCTION MOORES CREEK ADVANCED WATER RESOURCE RECOVERY FACILITY ENGINEERING BUILDING ADDITION RIVANNA WATER & SEWER AUTHORITY CHARLOTTESVILLE, VIRGINIA 31442-002 01 MAY 2020B. EDWARDS IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 4011 WESTCHASE BLVD, SUITE 500 RALEIGH, NC 276071REGULATORY REVIEW 05/2020 LMS 1