HomeMy WebLinkAboutSDP200800041 Review Comments 2008-03-28Albemarle County
Service Authority
Serving Conserving —
TO: Gerald Gatobu
FROM: Gary Whelan, Civil Engineer
DATE: March 28, 2008
RE: Site Plan Technical Review for:
North Pointe - Northwest Residential Area
SDP200800041
TM 32 -22K & 22H
The below checked items apply to this site.
X 1. This site plan is within the Authority's jurisdictional area for:
X A. Water and sewer
B. Water only
C. Water only to existing structure
D. Limited service
X 2. A 12 inch water line is located approximately 50' distant.
X 3. Fire flow from, nearest public hydrant, located 300' distant from this site plan,
is 3,000 Gpm + at 20 psi residual.
X 4. An 8 inch sewer line is located approximately 600' distant.
5. An Industrial Waste Ordinance survey form must be completed.
X 6. No improvements or obstructions shall be placed within existing or future
easements.
7. and plans are currently under review.
8. and plans have been received and approved.
9. No plans are required.
X 10. Final water and sewer plans are required for our review and approval
prior to granting tentative approval.
11. Final site plan may /may not be signed.
X 12. RWSA approval for water and /or sewer connections.
13. City of Charlottesville approval for sewer.
Comments: Gravity sewer can not be directed to the North Fork Research Park
pump station.
The site plan does not show or incorrectly shows:
meter locations water line size
waterline locations sewer line size
sewer line locations expected wastewater flows
easements expected water demands
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434977 -4511 • Fax (434)979 -0698
www.serviceauthoriy.org