Loading...
HomeMy WebLinkAboutARB202000071 Other (not approved) 2020-06-15`m Know what's below. Call before you dig. SITE INFORMATION PROJECT DESCRIPTION: SITE ADDRESS: LATITUDE (NAD 83): LONGITUDE (NAD 83): EXISTING GROUND ELEVATION: PROPOSED GROUND ELEVATION JURISDICTION: ZONING: PARCEL ID: PARCEL AREA: PARCEL OWNER: TOWER OWNER: STRUCTURE TYPE: HEIGHT OF TOWER: OVERALL HEIGHT: RAD CENTER: TOTAL LEASE AREA: DISTURBED AREA: POWER PROVIDER: TELCO PROVIDER: INSTALLATION OF TELECOMMUNICATIONS TOWER WITH ANTENNAS AND ASSOCIATED EQUIPMENT. GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 380 02' 38.9608" -780 45' 04.8078" 773.5' (A.M.S.L.) 774' AT TOWER BASE ALBEMARLE COUNTY ENTRANCE CORRIDOR (EC) & GREENWOOD AFTON RURAL HISTORIC DISTRICT 05400-00-00-072AO 1.0980 ACRES SCRUBY, BRIAN G. P.O. BOX 83 GREENWOOD, VA 22943 VERIZON WIRELESS 1831 RADY COURT RICHMOND, VA 23335 MONOPOLE 108' ±AG L 11 0'±AGL 104' ±AG L 1600 SQ. FT. 3,900 SQ. FT. DOMINION VIRGINIA POWER (888) 837-4966 VERIZON (800) 483-3000 EMERGENCY INFORMATION: ALBERMARLE COUNTY FIRE & RESCUE: (434) 977-9041 ALBERMARLE COUNTY SHERIFF'S OFFICE: (434) 977-9041 CONSTRUCTION MANAGER: PROJECT TEAM TCM DENNIS TUCK 804-347-6592 PROJECT MANAGEMENT FIRM: GDN NATE HOLLAND 757-305-8420 ENGINEERING FIRM: NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE SUITE 100 GLEN ALLEN, VA 23060 (804) 548-4079 E SITE NAME: MIRADOR FARM GREENWOOD STATION ROAD (JUST SOUTH OF I-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY VICINITY MAP SCALE: 1" = 3000' Jarman Gap Krrg Farr''y Vineyards y j2 Old Trail G0 SITE e� ie M a�Q Joseph T He^iey M idd!e School Greenwood it Brow Pro Re Nata Brewery C� Yancey Miils Westemtmare VOOT Workers High School Memorial � 38- 02 36.9608" ? -78' 45' 04.8078 ,COish Gap Tpke Misty Mountain. Camp Resort 0 z w Pollak Vireyards •7 ,ticiisRGapt e T Midway rpke y�, GaP��Rooster Hill,l Bed & Newtown Rot Break`ast r, DIRECTIONS FROM: 2501 GOODES BRIDGE ROAD. EXIT THE GOODES BRIDGE MSC PARKING LOT AND TURN RIGHT ONTO GOODES BRIDGE ROAD. TURN RIGHT ONTO US-360 E / HULL ST RD. TAKE RAMP RIGHT FOR VA-150 NORTH TOWARD POWHITE PKWY. TAKE RAMP RIGHT AND FOLLOW SIGNS FOR VA-76-TOLL NORTH. KEEP LEFT TO STAY ON VA-76 N / BELTLINE EXPY. KEEP STRAIGHT ONTO 1-195 N. TAKE RAMP FOR 1-64 W. AT EXIT 107, TAKE RAMP RIGHT FOR US-250 TOWARD CROZET / YANCEY MILLS. TURN LEFT ONTO US-250 W / ROCKFISH GAP TPKE. TURN RIGHT ONTO GREENWOOD STATION RD. ARRIVE AT SITE ON THE RIGHT. CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. • 2015 INTERNATIONAL BUILDING CODE • 2015 VIRGINIA CONSTRUCTION CODE • 2014 NATIONAL ELECTRICAL CODE • ANSI/TIA-222-G • 2015 NFPA 101, LIFE SAFETY CODE • TIA 607 • 2015 IFC • INSTITUTE FOR ELECTRICAL & ELECTRONICS ENGINEER 81 • AMERICAN CONCRETE INSTITUTE • IEEE C2 NATIONAL ELECTRIC SAFETY CODE LATEST EDITION • AMERICAN INSTITUTE OF STEEL CONSTRUCTION • TELECORDIA GR-1275 • MANUAL OF STEEL CONSTRUCTION 14TH EDITION • ANSI/T 311 DRAWING INDEX T-1 TITLE SHEET EE-1 EASEMENT EXHIBIT EE-2 EASEMENT EXHIBIT Z-1 OVERALL SITE PLAN Z-2 ENLARGED SITE PLAN Z-3 TREE INVENTORY Z-4 2,000' TOPO BOUNDARY C-1 COMPOUND PLAN C-2 TOWER ELEVATION DETAILS & NOTES C-3 MOUNT DETAILS S-1 CONSTRUCTION DETAILS S-2 EQUIPMENT MOUNTING DETAILS ES-1 EROSION & SEDIMENT CONTROL PLAN ES-2 EROSION & SEDIMENT CONTROL NOTES ES-3 EROSION & SEDIMENT CONTROL DETAILS I ES-4 EROSION & SEDIMENT CONTROL DETAILS II DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED TO BE FULL-SIZE AT 24"X36". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE DESIGNER / ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. CONTRACTOR SHALL USE BEST MANAGEMENT PRACTICE TO PREVENT STORM WATER POLLUTION DURING CONSTRUCTION. APPROVAL BLOCK rr w rw V z w 0 Q O Ll_ z w v� 0 0 U w Iz Z w 0 Q z O w LL cc w w w z_ C� z w w _J w w U) Cr w m z w w NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ 1831 RADY COURT RICHMOND, VA 23222 MIRADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CCC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CCC REV DATE DESCRIPTION BY �LTH OF K�,�cl_�� 9 JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020' SIOIVAL V 0* JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 TITLE SHEET T=1 SEE EE i EG lR LEGAL DESCRIPTION LESSEE 107' MONOPOLE TOWER LAT: 38'02'38,9608" / LON:78'45'04.8078" 64 GROUND ELEVATION 773.5' (NAVD 88) TAtE R/W / r \ CN / s7 R 76 Q Z QzZ� AV J � / I !3 OL P DT VAR SHpB 4' o / / i / NIF BRIAN C. SCRUBY \ e D.B. 1868; PC. 598 i TMP 54-72A 0 �t31 485 1 ➢89�j1� LESSEE 40' x 40' LEASE AREA \ INV lb••1. 82 i _. \ mr ED � 1F 1� j Q INV 751.14 \p —112 ( Q c SCALE l 50' 0' 50' 100' 150' N IF SEVEN DAI<,' FARM LLC D. B. 1974, PG'. 390 TMP C5-15 O O LESSEE 20 ACCESS v & UTIHTY EASEMENT TREE INVENTORY NUMBER SPECIES CALIPER AGL HEIGHT CANOPY HEIGHT (134) OAK 18" 81' 856' AMSL (136) OAK 12" 55' 829' AMSL (138) PERSIMMON 2C 54' 827' AMSL (140) OAK 15' 69' 841' AMSL (142) OAK 8" 65' 842' AMSL (144) OAK 20" 77' 852' AMSL (146) OAK 24" 77' 852' AMSL (148) DEAD OAK 14" N/A N/A (149) OAK 12" 84' 859' AMSL (151) PINE 14" 95 870' AMSL (155) PINE 10" 86' 862' AMSL (157) PINE 10" 97 872 AMSL (159) PINE 10" 82' 858' AMSL (161) PINE 14" 84' 860' AMSL (163) PINE 10" 80' 856' AMSL (165) PINE 14" 86' 862' AMSL (167) OAK 15" 89' 864' AMSL (169) PINE 10" 64' 840' AMSL (171) PINE 8" 56' 832' AMSL (173) OAK 12" 75' 851' AMSL (175) PERSIMMON 12" 71' 848' AMSL (177) PINE 10" 81, 858' AMSL (179) OAK 12" 60, 8,iT AMSL (181) PINE 10" 64' 841' AMSL (IBm OAK 16" 72' 849' AMSL (18'5) OAK 10" 73' 851' AMSL (IR7) OAK 12" 76' 854' AMSL (189,) PERSIMMON 18" 87' 865' AMSL *TTAL TREES TO BE REMOVED: TO BE DETERMINED NOTES: '.REFERENCE TREE IS IDENTIFIED ABOVE IN BOLD,. 2.TREE DRIPLINES ARE DRAWN TO SCALE. 3.UNDERLINED TREE HEIGHTS HAVE BEEN CONFIRMED BY A THIRD PARTY TOWER CLIMB, Ll 1**jE9mlmC, TOTALLY COMMITTED z w NB+C ENGINEERING SERVICES, I.I.C. I I GLEN A—N. VA 33Ufd1 6MS1B.dD�9 U ve rizo n CL --1 LL Q 1831 RADY COURT RICHMOND, VA 23222 0 NB&C #02671 ~ a EASEMENT EXHIBIT � Y SITE NAME: MIRADOR r' 7416 GREENWOOD STATION RD GREENWOOD; VA 22943 ALBEMARLE COUNTY, VA 0 EF 0 U w 1Y z 0 Ln C) THIS EXHIBIT DOES NOT CONSTITUTE A BOUNDARY SURVEY z AND IS FOR THE EXPRESS PURPOSE OF SHOWING PROPOSED LEASE AREAS. w 111=511mIINmk 1 6/9/20 ADD ADJOINING R/W RW 0 11/1/17 EASEMENTEXHIBIT RW EV DATE DESCRIPTION BY ��TH OF OBERT T. WILLIAMS' JR.� LIC. No. 002551 6-9—,2020 `C �avUuseway Consultarts, P.C_ Land Surveyors VA&NC P.0 BOX 15039 CHESAPEAKE, VA. 23328 PHONE: 7s7-482-0474 C—SMAY CQNsu­ —. 2.. EASEMENT EXHIBIT EE-1 THIS EXHIBIT DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS FOR THE EXPRESS PURPOSE OF SHOWING PROPOSED LEASE AREAS. INERSIA TE 64 VARIABLE WIDTH RAW SHPB 4, P(3S. I0.3- 1 a6 LESSEE 40' x 40' LEASE AREA I I - - F L�7 Q�) III z � L9 T L5 a c):: , I I I I � r LEGAL DESCRIPTION PROPOSED 20' UTIHTY AND ACCESS EASEMENT A PROPOSED 20' UTILITY AND ACCESS EASEMENT OVER AND ACROSS TAX MAP 4m PARCEL 54 72A AS :SHOWN IN DEED BOOK 3,390, AT PAGE 652 OF RECORD IN THE CLERK OF THE CIRCUIT COURTS OFFICEALBEMARLE COUNTY 1/IRGINIA LYING z ALONG THE EASTERLY RICHT OF WAY OF STATE ROUTE 690, BEING MORE TOTALLY COMMITTED T /, �/ C� �1 C' z PARTICULARLY DESCRIBED AS FOLLOWS w NB+C ENGINEERING SERVICES, I.I.C. "15 AATERFRO DRIVE SURE 1W UEN ALLEN. VA 2306p 961.59S.dfi)8 BEGINNING AT AN IRON PIN AT THE SOUTHWESTERLY MOST CANNER OF SAID TAX N/F MAP PARCEL 54-72A; THENCE ALONG A 71E LINE N 01 21 '19" E A DISTANCE OF BRIAN G. SCRUBY 3.38 7-0 A POINT BEINO THE TRUE POINT AND PLACE OF BEGINNING OF A D.B. 1368, PC, 5 S PROPOSED 20' ACCESS AND UTILITY EASEMENT TMP 54-72A THENCE OVER AND ACROSS SAID TAX MAP PARCEL 54-72A FOLLOWING COURSES: z v� ri z® n THENCE N 01 °21 ' 19 " E A DISTANCE OF 20. 39 ' TO A POINT - THENCE N 80'05'22" E A DISTANCE OF 32.06A TO A POINT,- L LL 1831 RADY COURT THENCE N 63`22 '16" E A DISTANCE OF 8. 13' TO A POINT,- Q RICHMOND, VA 23222 THENCE N 01020 26 „ E A DISTANCE OF 71. 43' TO A POINT,° THENCE N 90 °00 A00 " E A DISTANCE OF 20. 01 ' TO A POINT, - THENCE S 0120 26 " W A DISTANCE OF 83° 92' TO A POINT - THENCE S 6JO22'16" W A DISTANCE OF 23 09TO A POINT- 0 THENCE S 80'05 22 " W A DISTANCE OF 38. 93 TO A POINT WHICH IS THE TRUE NB&C #02671 POINT AND PLACE OF BEGINNING, HA 1%INO' AN AREA OF 2,576 SQUARE FEET, Q EASEMENT EXHIBIT IC o SITE NAME: MIRADOR O. 059 ACRES, STATION LEGAL DESCRIPTION PROPOSED 40' x 40 LEASE AREA z 7416GREENwooDVA2294 RD GREENWOOD. VA 22943 LLI A PROPOSED 40' x 40' LEASE AREA ON TAX MAP PARCEL 5472A AS SHOWN ALBEMARLE COUNTY, VA IN DEED BOOK 3390, AT PAGE 652 OF RECORD IN THE CLERK OF THE / CIRCUIT COURTS OFFICE, ALBEMARLE COUNTY; VIRGINIA; LYING ALONG THE EASTERLY RIGHT OF WAY OF STATE ROUTE 690, BEING MORE PARTICULARLY Y REVISIONS / DESCRIBED AS FOLLOWS;^ 91111111111111111 EDOT MON(F) P.0°8° FOR LEASE AREA LESSEE 20 ACCESS L % UTILITY EASEMENT N/F SEVEN OAKS FARM LLC D.B. 7974, PG. J90 7-MP 55-15 LINE TABLE IRON PIN(F) P.O.H. FOR ACCESS & UTILITY EASEMENT N 0121 '1.9" E 3.38' (TIE LINE) SCALE l ,Z 259 25' 50' 75' LINE BEARING DISTANCE L I N 0121 '19" E 20.,39' LEG N 80005'22" E 32.06' Li IV 6322'16" E 8. I3' L4 N 07 20,26" E 71.43' L5 N 90600'00" E 20.01 ' L6 S O 120 26" W 83.92' L7 S 6322'16" W 23.09 L8 S 80005'22" W 38.98' L9 DUE WEST 40.00' L IO DUE NORTH 40, 00' L 17 DUE FAST 40.00' L 12 DUE SOUTH 40.00' BEGINNING AT A HDOT MONUMENT ALONG THE SOUTHERLY BOUNDARY OF SAIID TAX MAP PARCEL 54-72A; THENCE ALONC A RE LIVE N 34958'45" W A DISTANCE OF 76.65' TO A POINT BEING THE TRUE POINT AND PLACE OF BEGINNING; THENCE DUE WEST A DISTANCE OF 40.00' TO A POINT, THENCE DUE NORTH A DISTANCE OF 40.00' TO A POINT,° THENCE DUE EAST A DISTANCE OF 40.00' TO A POINT, THENCE DUE SOUTH A DISTANCE OF 40.00' TO A POINT; WHICH IS THE POINT OF BEGINNING, HAVING AN AREA OF l q , 600 SQUARE FEET OR 0.037 ACRES, EXHIBIT NOTES 1. TOPOGRAPHIC SURVEY PERFORMED BY CAUSEWAY CONSULTANTS, P.C. P. 0. BOX 15039. CHESAPEAKE, VIRGINIA, 23328-50394. PHONE; 757-482-0474. SURVEY DATE: MAY 24, 2017. 2. COORDINATES AND ELEVATIONS SHOWN WERE ESTABLISHED USING STATIC CPS OBSERVATIONS, POST PROCESSED THROUGH NOAA'S OPUS WEBSITE AND CONVERTED TO NAVD 88 AND NAD 83, U.S SURVEY FOOT, FOR THE VERTICAL DATUM AND HORIZONTAL COOROIANTES, RESPECTIVELY, USING U.S. ARMY CORPS OF ENGINEERS CORPSCON SOFTWARE, VERSION 6,01 AND PUBLISHED BENCHMARKS. 3. NO SUB -SURFACE INVESTIGATION WAS PERFORMED BY CAUSEWAY CONSULTANTS, P.C. THIS EXHIBIT DOES NOT GUARANTEE THE "EXISTENCE OR NONEXISTENCE" OF UNDERGROUND UTILITIES. PRIOR TO ANY CONSTRUCTION OR EXCAVATION, CONTACT MISS UTILITY AT 1 800-552-7001 TO CONFIRM THE LOCATION OR EXISTENCE OF UNDERGROUND UTILITIES. 4. THIS EXHIBIT WAS DONE WITHOUT THE BENEFIT OF A TITLE REPORT AND MAY NOT DEPICT ANY OR ALL EASEMENTS THAT MAY AFFECT THE PROPERTY. 5. PROPERTY IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 6. THIS EXHIBIT DOES NOT REPRESENT A BOUNDARY SURVEY. THE RIGHT-OF-WAY, PROPERTY LINE AND/OR EASEMENTS SHOWN HEREON REPRESENT A COMPILATION OF RECORDED DEEDS, PLATS, G_I.S. RECORDS AND TAX MAPS. 7. THE AREA OF THE PROPOSED CELL TOWER APPEARS TO LIE WITHIN FLOOD ZONE "X", ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY -- NATIONAL FLOOD INSURANCE COMMUNITY NUMBER 51003C-0225 D; DATED FEBRUARY 4 2005. 8. THE EXISTENCE OF HAZARDOUS WASTE, VEGETATED WETLANDS, OR TIDAL WETLANDS, WAS NEITHER INVESTIGATED, NOR CONFIRMED DURING THE PERFORMANCE OF THIS EXHIBIT: 0 Il/l/17I EASEMENT EXHIBIT IRW REV DATE DESCRIPTION BY OBERT T. WILLIAMS, JR.y LIC. No. 002551 I1-9-2017 C � SUR\ � 0 0 �\CausewaV Consultants, P.C. > Land Surveyors VA&NC P.0 BOX 15039 CHESAPEAKE VA- 23328 (n PHONE. 757-482-0474 -AUSEWAY CONSULTANTS, P.C. 'ANON L_ EASEMENT LIT EXHIBIT I f PROPOSED 12' WIDE INTERSTATE 64 VARIABLE WIDTH 1?1W SHPB 4, PGS, 10,3 106 SHPB I /, PG. 258 i 1 64 1 !ATE 64 lE/ 1N-�ERS� P ---------- 1 SITE PLAN Z-1 SCALE: 1" = 40' PROPOSED 108' FALL RADIUS GRAPHIC SCALE 40 0 20 40 80 (IN FEET) 1 INCH = 40 FEET �NE �TYP•� /G PR��ER E EXISTING TREE LINE 160 ZONING MAP 54-61- '� . 54-67 54j61 55-12E ;x 54.740 5-01 54.716 54-7 fA .•ram �'Y_,.--�" - y 611 _y a l SITE LL° s fARM1 • � p�� L'1 tAKE� - 71_T+ GENERAL NOTES 1. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 2. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 3. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN HABITATION. THERE IS NO HANDICAP ACCESS REQUIRED. 4. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. LEGEND PROPERTY LINE SUBJECT PARCEL PROPERTY LINE - ABUTTERS EXISTING ROAD — EXISTING FENCE - - - PROPOSED EASEMENT - - PROPOSED LEASE AREA - - EXISTING EASEMENT -_ x x •— PROPOSED FENCE EXISTING BUILDING CRITICAL SLOPES / 100 YEAR FLOOD PLAIN \\\\ WATER PROTECTION ORDINANCE BUFFER NOTE: BUILDING AND ELECTRICAL PERMITS ARE REQUIRED FOR THE TOWER AND STRUCTURE GREATER THAN 150 SQUARE FEET HOUSING EQUIPMENT AND ELECTRICAL SERVICE.. TM W (z TOTALLY COMMITTED® V z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri o nit J a Q 1831 RADY COURT RICHMOND, VA 23222 z M I RADOR FARM 0 Q VERIZON RAWLAND GREENWOOD STATION ROAD o LL (JUST SOUTH OF 1-64) LU GREENWOOD, VA 22943 n ALBEMARLE COUNTY ry- 0 W z W c] W Q co z 0 C� W W rr a_ R pr W CD Know what's below. W Call before you dig. _ REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CGC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED GCG 1 04/14/20 REVISED GCC 0 04/08/20 PRELIMINARY ZDs CGC REV DATE DESCRIPTION BY 10H gyp- Grp ° cl— � � y JOHN A. DAUGHTREY III Lic. No. 0402052122 p 06/11/2020 ssjolval. �� JOHN A. DAUGHTREY III, P.E. I VA PROFESSIONAL ENGINEER LIC. #052122 OVERALL SITE PLAN Zm i i f I I 1 i EXISTING GUARD RAIL 1-1 O W 0 Q O ry z O Q O >O W cif (D EXISTING EXISTINC ACCESS FROM R. C. W. (PTO BE UTILIZED ENLARGED SITE PLAN Z-2 SCALE: 1" = 10' GRAPHIC SCALE 10 0 5 10 20 (IN FEET) 1 INCH = 10 FEET 40 LEGEND PROPERTY LINE — SUBJECT PARCEL rr w w z CD W TM 1 - , µ- TOTALLY COMMITTED. PROPERTY LINE - ABUTTERS II I I I NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 EXISTING ROAD EXISTING FENCE — — — — PROPOSED EASEMENT — — — PROPOSED LEASE AREA EXISTING EASEMENT —z ■— PROPOSED FENCE EXISTING BUILDING Know what's below. Call before you dig. 0 Q 0 H z w rr O W z 0 W 0 J z O U) H rr I1 w w z_ 0 z w m z W w U) veri on,/ 1831 RADY COURT RICHMOND, VA 23222 M I RADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CGC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CCC REV DATE DESCRIPTION BY op- �o � o,XA � 9, JOHN A. DAUGHTREY III Lic. No. 0402052122 ' S06/11/2020 S��NAL �G JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 ENLARGED SITE PLAN Z-2 h, 0 z w D Gr PROPOSED 10 MONOPOL EXISTING GUARD RAIL 0 W F— ry � � W ry \ C9 � EXISTING CUL VER 4 EXISTING ACCESS FROM R. O. W (To BE UTIL IZED (" TREE INVENTORY �-3SCALE: 1" = 10' GRAPHIC SCALE 10 0 5 10 20 (IN FEET) 1 INCH = 10 FEET 40 N OTE: 1. EXTREME CARE SHALL BE TAKEN NOT TO DAMAGE EXISTING TREES THAT ARE TO REMAIN. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OR COMPENSATION OF DAMAGED TEES. SITE SHALL BE MAINTAINED IN CORDANCE WITH A TREE CONSERVATION 4N TO BE PREPARED BY A CERTIFIED BORIST. AS REQUIRED BY C.5.1 .40(C)(4). TRIM EXISTING BRANCHES THAT ENCROACH -0 THE FENCED IN COMPOUND AREA. TO BE REMO VE5 To BE REMOI/EC TO BE REMO VE5 To BE REMOI/EG TOP BROKEN TO BE REMO VE5 TO BE REMOVE TO BE REMOVED TO BE REMO VE-5 TO BE REMOVED LEGEND PROPERTY LINE SUBJECT PARCEL PROPERTY LINE — ABUTTERS EXISTING ROAD EXISTING FENCE PROPOSED EASEMENT PROPOSED LEASE AREA EXISTING EASEMENT PROPOSED FENCE EXISTING BUILDING TREE INVENTORY NUMBER SPECIES CALIPER AGE HEIGHT CANOPY HEIGHT (134) OAK 18" 94' 869' AMSL (156) OA K 12 " 05 ' 8,39 ' A MSL (138) OAK 20" 76' 849' AMSL (140) POPLAR 15" 66' 839' AMSL (142) POPLAR 8" 60' 833' AMSL (144) OAK 20 71 ' 845' AMSL (146) OAK 24„ 81 ' 854' AMSL (148) DEAD OAK 14 " A///A IV/A (149) OAK 12 ' 67, 355' AMSL (151) PINE 14" 82' 856' AMSL (155) PINE 10" 78' 852' AMSL (157) PINE 1014 79' 854' AMSL (159) PINE 10" 54' 828' AMSL (161) PINE 14" 86' 862' AMSL (163) PINE 10" 80' 856' AMSL (165) PINE 14" 79' 855' AMSL (167) OAK 15" 74' 850' AMSL (169) PINE 10" 40' 816' AMSL (171) PINE 8" 61' 836' AMSL (173) OAK 12" 95, 872' AMSL (175) OAK 12" 64' 842' AMSL (177) PINE 10" 77' 854' AMSL (179) OAK 12" 71 ' 848' AMSL (181) PINE 10" 80' 857' AMSL (183) POPLAR 16" 93 870' AMSL (185) OAK 10" 77' 855' AMSL (187) OAK 12" 80' 859' AMSL (189) POPLAR 18" 87' 866' AMSL (191) POPLAR 6" IV/A NIA (193) POPLAR 12' N/A NIA (195) OAK 12" NIA N/A (197) HICKORY 8„ NIA NIA (199) PINE 0 „ NIA N/A (201) PINE 6 A NIA N/A (20J) OAK 10" NIA N/A (205) MAPLE 8 " NIA NIA (207) OAK 16" IV/A NIA (209) OAK 8„ N 'A NIA (211) OAK 1 C N/A N/A (213) OAK 8" N; A N/A (215) OAK 14 NIA NIA (217) OAK 14" NIA N!A (219) OAK 8" NIA NIA (221) 0/4K 12„ N/A NIA (223 HICKORY 8 P NIA NIA (225) OAK 10" NIA N/A *TOTAL TREES TO BE REMOVED; TO BE DETERMINED NOTES: 1. REFERENCE TREE IS IDENTIFIED ABOVE IN BOLD. 2, TREE DRIPLINES ARE DRAWN TO SCALE. 3. UNDERLINED TREE HEIGHTS HAVE BEEN CONFIRMED BY A THIRD PARTY TOWER CLIMB. Know what's below. Call before you dig. rr W W z 0 z W 0 Q 0 H z W 0 m O w z U) W 0 a_ Q z O U) H rr W rr LU W z_ 0 z W LLJ W U) m z w W U) TM TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ 1831 RADY COURT RICHMOND, VA 23222 M I RADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CGC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CCC REV I DATE I DESCRIPTION I BY �x op� 7N� �o c o XA 0 1, 9, JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020 ss�a�vaL �� JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 TREE INVENTORY Z=3 2,000' TOPO BOUNDARY SCALE: 1" = 300' GREENWOOD STATION RD I \ ) `l 2,000' TOPO BOUNDARY \ I I I I I V 1-64 l GRAPHIC SCALE 300 0 150 300 600 1200 (IN FEET) 1 INCH = 300 FEET i ZONING MAP 54-61- '� . 54-67 - 55.13A 54j61 - - 55-12E: 54.740 F 54 71 54.71B 54-71A .•ram �'Y_,.--�" - y SITE r D LL° f f A.. 71-2A 71-2 71-26 GENERAL NOTES 1. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 2. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 3. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN HABITATION. THERE IS NO HANDICAP ACCESS REQUIRED. 4. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 5. ALBEMARLE COUNTY GIS IS THE SOURCE FOR TOPO LINES SHOWN. LEGEND PROPERTY LINE SUBJECT PARCEL PROPERTY LINE - ABUTTERS EXISTING ROAD EXISTING FENCE - - - - PROPOSED EASEMENT ■ W - W z TOTALLY COMMITTED. 0 z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ J d Q 1831 RADY COURT RICHMOND, VA 23222 0 Q 0 W UD cr OO W z 0 W 0 M I RADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CCC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14120 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CCC - - - - PROPOSED LEASE AREA 11 I I I REV I DATE I DESCRIPTION � BY - - - - EXISTING EASEMENT PROPOSED FENCE EXISTING BUILDING' Know what's below. Call before you dig. W Q Cn Z 0 W LL W cr W C� LU W W W rr W m z H- W W U) OF �o � o 01- , JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020 �- S`�jC1VAL �G JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 290001 TOP O BOUNDARY Z-4 5' TO LEASE AREA I I x I x o O O ° w Q I O LLI a w I J I x O O O O x O O I I x x x x x PROPOSED VERIZON 3' H—FRAME FOR 200A UTILITY METER & Know what's below. Call before you dig. rl-'� THE EXISTING UTILITY INFORMATION SHOWN REPRESENTS THE BEST DATA AVAILABLE FROM EXISTING DOCUMENTATION AND FIELD EVIDENCE. ALL LOCATIONS SHOULD BE CONSIDERED APPROXIMATE, AND A FIELD INVESTIGATION MUST BE PERFORMED IN THE VICINITY OF ANY rnr\igTRI irTinr\i o('TiviTiP'q Nlr)TF THAT THESE PLANS MAY PRESE3NT AT THE SITE. 30, COMPOUND -x x x x PROPOSED VERIZON EQUIPMENT CABINET F PROPOSED VERIZON ICE BRIDGE ABOVE H—FRAME EQUIPMENT PROPOSED VERIZON 3'-6"X8' CONCRETE PAD FOR GENERATOR PROPOSED VERIZON 108' MONOPOLE TOWER X—\ -,-\ PROPC 12' WI GATE W W W z TOTALLY COMMITYL C� z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ J a Q 1831 RADY COURT RICHMOND, VA 23222 z M I RADOR FARM 0 Q VERIZON RAWLAND GREENWOOD STATION ROAD H (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS m v 0 5 06/11/20 REVISED PJP U W Iz 4 06/09/20 FINAL CGC z 0 3 05/22/20 REVISED CCC Cf) 2 04/24/20 REVISED CCC Q 0 04/08/20 PRELIMINARY ZDs CCC REV DATE DESCRIPTION BY I 0 f- I Q i PROPOSED 17"x30" / FIBER HAND HOLE I Q NEXT TO THE I Z ILOCATED MESA CABINET PROPOSED BOLLARD O JOHN A. DAUGHTREY III (TYP. OF 2) I Lic. No. 0402052122 � I 06/11/2020 0 sSj�IVALG I I I I I I � I I I I � z JOHN A. DAUGHTREY III, P.E. 40' LEASE ARE 1 COMPOUND PLAN C-1 SCALE: 3/8" = 1'-0" GRAPHIC SCALE 2 0 1 2 4 8 (IN FEET) 3/8 INCH = 1 FOOT (D I I VA PROFESSIONAL ENGINEER LIC. #052122 II W J w COMPOUND PLAN W U) w m Dilcmi W W 2 Cl) GENERAL NOTES ELEVATION 8 SCALE: 1/8" = 1' C-2 GRAPHIC SCALE 0 4 8 16 32 (IN FEET) 1 INCH = 8 FEET PROPOSED 2' LIGHTNING ROD (DESIGN BY OTHERS) 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITIES COMPANY OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 8. TRANSMITTER EQUIPMENT AND ANTENNAS ARE DESIGNED TO MEET ANSI/TIA 222—G REQUIREMENTS. 9. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 10. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 11. IF ANY UNDERGROUND UTILITIES OR STRUCTURES EXIST BENEATH THE PROJECT AREA, CONTRACTOR MUST LOCATE IT AND CONTACT THE APPLICANT & THE OWNER'S REPRESENTATIVE. 12. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION BY TECHNICIANS APPROXIMATELY 2 TIMES PER MONTH. 13. PRIOR TO THE INSTALLATION OF THE PROPOSED EQUIPMENT OR MODIFICATION OF THE EXISTING STRUCTURE, A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER'S AGENT TO CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, COAXIAL CABLES AND OTHER APPURTENANCES. 14. PROPERTY LINE INFORMATION WAS PREPARED USING DEEDS, TAX MAPS, AND PLANS OF RECORD AND SHOULD NOT BE CONSTRUED AS AN ACCURATE BOUNDARY SURVEY. W W z TOTALLY��L L �. z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ J a Q 1831 RADY COURT RICHMOND, VA 23222 z M I RADOR FARM O Q VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) I -- GREENWOOD, VA 22943 �0- ALBEMARLE COUNTY REVISIONS 15. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF C — RECORD. 0 5 06/11/20 REVISED PJP 0 06/09/20 FINAL cGC 16. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN W 4 STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. z 3 05/22/20 REVISED CCC U) 17. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. Q 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 18. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN HABITATION (NO HANDICAP ACCESS REQUIRED). 0 04/08/20 PRELIMINARY ZDs CCC 19. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. REV DATE DESCRIPTION BY 20. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. Know what's below. Call before you dig. ,i1 Q z 0 JOHN A. DAUGHTREY III Lic. No. 0402052122 �'p� W 06/11/2020 W 0 DNAL W W W JOHN A. DAUGHTREY III, P.E. z C3 1 1 VA PROFESSIONAL ENGINEER LIC. #052122 W II W J TOWER ELEVATION W W & NOTES m W m z � w W UD NOTE: TWO OF THESE MOUNTS ARE REQUIRED FOR THIS SITE. THE (6) 3.5" SCH. 40 X 18' LONG PIPE MOUNTS ARE SOLD SEPARATELY. THE PIPE MOUNTS WILL SPAN BETWEEN THE TWO COMPACT MONOPOLE MOUNTS AS SHOWN ON SHEET C-2 SITE PRO 1 —COMPACT VONOPOLE MOUNT (PART # UWS6—NP) NOTE: CONTRACTOR TO PROVIDE SITE PRO 1 —COMPACT MONOPOLE MOUNT (PART # UWS6—NP) OR APPROVED EQUIVALENT ANTENNA & RRH MOUNT DETAIL SCALE: NTS PROPOSED 117' MONOPOLE (1 TOTAL ON� TOWER) '0 1 —RING MOUNT � UGLM—DCP) PROPOSED OVP ORIENTATION PLAN - 95' MOUNT CENTER NTS APPROX TRUE NORTH (I (3) PROPOSED 2" STD 6' L OR SITE PRO 1 —R (PART # UGLM—DCP) PIPES. NOTE: CONTRACTOR TO PROVIDE SITE PRO 1 —RING MOUNT (PART # UGLM—DCP) OR APPROVED EQUIVALENT 2 OVP MOUNT DETAIL C-3 SCALE: NTS —COMPACT MOUNT (PART (12 TOTAL ON TOWER) PROPOSED RRH ORIENTATION PLAN - 102' RAD CENTER NTS APPROX TRUE NORTH (I W W z TOTALLY��L L �. z w NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 1573.. 0 veri on,/ _j 0 00< 1831 RADY COURT 0 RICHMOND, VA 23222 RAYCAP OVP BOX #RHSDC-3315-PF-48 NTS (12 TOTAL ON TOWER) )MPACT JNT (PART PROPOSED RRH ORIENTATION PLAN - 102' RAD CENTER NTS APPROX TRUE NORTH (I z M I RADOR FARM 0 Q VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) LIJ GREENWOOD, VA 22943 Cf) ALBEMARLE COUNTY REVISIONS w rd, 0 5 06/11/20 REVISED PJP 0 W m 4 06/09/20 FINAL uCC z 0 3 05/22/20 REVISED CCC U) W 2 04/24/20 REVISED CCC 0 C� z 0 w H rr W w w z_ 0 z w W w W U) Cr W z w w UD i!!iLlNzil�:l:kvl&"Ul'<iiKSl 0 04/08/20 PRELIMINARY ZDs CCC REV DATE DESCRIPTION BY rVAH Op 4 JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020 �S'S j�1VAL �G JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 MOUNT DETAILS C=3 6" AASHTO #57 CLEAN STONE 1.9 x ,— FENCE LINE hi —III II M I RAFI 50OX GEOTEXTILE FABRIC GRAVEL COMPOUND DETAIL NTS BOARD -ON -BOARD BOARD ON BOARD WOODEN FENCE 8' WIDE GATE LEAF I' 1 1 5/8" 0 PIPE FRAME GATE WITH MECHANISM I I p 1 5/8" 0 PIPE i� FRAME GATE I WITH MECHANISM � JH'I --- --- ---- ---- ---- -- --It tfl FINISH GRADE ! Le'. P..' ) i \ C v }V \ C Y GALVANIZED MUSHROOM STOP. - SEE 4/S-2 FOR DETAILS. INTERMEDIATE, 10" & GATE 'owl I, �, .. ., a .. CORNER POSTS I N 1'-6". 8'-0" 8>-0" (TYP.) 16'-0" FRONT GATE 3 TYPICAL FENCE AND GATE DETAIL .. NTS 8'-0" O.C. (MAX.) WIA J 2" GAP BETWEEN I° ; WOOD PANEL AND GRAVEL u . CONCRETE FOOTING (4000 PSI ® 28 DAYS, PORTLAND CEMENT CONCRETE) 6"X6" PRESSURE TREATED WOOD POST (TYP.) 1 /2" CROWN FOR DRAINAGE EXTEND STONE 1'—O" BEYOND FENCE ON ALL 4 SIDES DRILLED PIER 4000 PSI CONCRETE. EMBEDDED PORTION OF ALL POSTS SHALL BE GENEROUSLY COATED WITH WOOD PRESERVATIVE TM ■ W N iB L W STOCKADE z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 r 6' MAX 2 TYPICAL GATE DETAIL S-1 NITS UNDISTURBED SOIL FENCE & GATE NOTES: 1 PROVIDE HALF MOON CONCRETE GATE KEEPER FOR DROP ROD 2. PROVIDE GATE CATCHES AT REQUIRED LOCATIONS 3. FENCE SHALL BE INSTALLED WITH THE FINISHED SIDE FACING OUTWARD 4. GATE TO BE SECURE WITH A MULTI —LOCK SYSTEM TO PREVENT UNAUTHORIZED ACCESS TO TELECOM FACILITY. MI INDUSTRIAL MAI J OFFSET PIN h GATE PANEL YP) 4-GANG METER BANK H-F RAM E NTS veri on,/ J a Q 1831 RADY COURT RICHMOND, VA 23222 z M I RADOR FARM O Q VERIZON RAWLAND GREENWOOD STATION ROAD o (JUST SOUTH OF 1-64) w GREENWOOD, VA 22943 n ALBEMARLE COUNTY REVISIONS ME 0 5 06/11/20 REVISED PJP U W 4 06/09/20 FINAL CCC z 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCG Q 1 04/14/20 REVISED GCC 0 104/08/20 1 PRELIMINARY ZDs I CGC REV I DATE I DESCRIPTION I BY P'O H OF _P6 01 Z JOHN A. DAUGHTREY III UD Lic. No. 0402052122 cf)w `�'p 06/11/2020 O W W LLJ W JOHN A. DAUGHTREY III, P.E. Z (D I I VA PROFESSIONAL ENGINEER LIC. #052122 n W CONSTRUCTION W W DETAILS co W Smi m Z W W C/O RESERVED SPACE CHARLES CA 18"x18" HOFFMAN BOX 24" WIDE ICE BRIDGE OVER H—FRAME EQUIPMENT AS NEEDED ON THIS SIDE MOUNT LIGHT SWITCH W/ TIMER ON END POST 24" WIDE ICE I OVER H—FRAME EQUI SWITCH/TIMER CHARLES CUBE #RL1003C—A EXCHANGER (120V) W/ TF UPS PART #SM150ORMXL2UT� 18"x18" HOFFMAN 1 n' 1 n' EQUIPMENT LAYOUT PLAN NTS REAR 6"X18" CONDU STUB —UP OPENIN 0 0 B 0 0 0 0 0 0 0 0 I A 0 o 0 e 0 0 0 o 0 0 o o H—FRAME RISER DETAILS NTS a OVP 6 0 Q w w 0 z 0 U I PROPOSED VERIZON WIRELESS CPS ANTENNA VERIZON WIRELESS EQUIPMENT: — CHARLES INDUSTRIES CUBE—SS413231 PX2 EQUIPMENT CABINET WITH BATTERY CABINET INCLUDED CONTRACTOR PROVIDED EQUIPMENT: * THIS IS NOT A COMPREHENSIVE LIST. IT SHOULD BE ASSUMED BY THE CONTRACTOR THAT ALL OTHER ITEMS DETAILED IN THIS SET OF DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR. — 26.2" WIDE X 78" TALL X 12.3" DEEP, ASCO D300L SERIES POWER TRANSFER LOAD CENTER MODEL AA3000-1 PH—N-3R — INTEGRATED LOAD CENTER "ILC" WITH COMBINATION PADLOCK. — 22" WIDE X 26" TALL X 20" DEEP, CHARLES INDUSTRIES CUBE—RL1003C—A W/ HEAT EXCHANGER (120V) W/ TRIPP—LITE UPS PART #SM150ORMXL2UTAA INSIDE (ONLY REQUIRED WHEN VzT PROVIDES LIT FIBER. UTILITY COORDINATOR MUST VERIFY IF THIS IS NEEDED) — RAYCAP OVP-6 (RCMDC-3315—PF-48) — COORDINATE ADDITIONAL ENTRY GATE LOCK(S) WITH CONSTRUCTION MANAGER. NOTES: 1. SEE SHEET E-1,E-2 & E-3 FOR FOR CABLE/CONDUIT ROUTINGS. 2. BOTTOM OF OVPs SHALL NOT EXCEED 36" ABOVE FINISHED GRADE. F77000C? <0D O O O O O O O O O 00000000 O O O O O O O O 0 000000 O O O O O O O 00 O O FRONT EQUIPMENT H—FRAME POST #1 SWITCH/TIMER 0 Q 0 LL z w Il Ir 0 U LJ m z C� co W Q z 0 U) LLJ LL rr W W W W Z C� LzLI w W w CL w z w W U) 4M NEB,imf 7 7 �= � D7 �1 ��,IJ T E Do NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ 1831 RADY COURT RICHMOND, VA 23222 M I RADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 106/11/20 1 REVISED I Pip 4 106/09/20 I FINAL I CCC 3 105/22/20 I REVISED I CCC 2 104/24/20 I REVISED I CCG 1 104/14/20 I REVISED I GCC 0 104/08/20 1 PRELIMINARY ZDs I CGC REV I DATE I DESCRIPTION I BY LT H OF G j� �yj � JOHN A. DAUGHTREY III Lic. No. 0402052122 p� 06/11/2020 ss JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EQUIPMENT MOUNTING DETAILS S-2 7-7 ----- ---------------------- I I ---------------- I \ ------------- --- , PROPOSED SILT FEN AROUND DOWN SLOPE DISTURBED AREA (APPROX. 200'f) I ! I I / � 3 - - - - - - - - - - - - - - - - - - � I N I 1\ \ f I / ------------------- PROPOSED VERIZON 108' ---- I MONOPOLE TOWER' I \\ I LL \ � � I I v, I \ ` PROPOSED TREE PROTECTION FENCE I AROUND PROPOSED COMPOUND AND APPROXIMATELY 50' OF PROPOSED aN I ACCESS ROAD AND TURN AROUND. IN (APPROX. LENGTH: 240't) I n I ! I \ I PROPOSED 12'X70' CONSTRUCTION / ENTRANCE. SEE SHEET ES-4 FOR DETAILS. � I 1 / 0 ' I _ I ------- I j'I I ----------------------- I I I I \ I G I 1v v I � I \ - - - - - - - - - - - - - \ } --- - - - PROPOSED OUTLET PROTECTION (SEE SHEET f / ES-4 FOR DETAIL) — II I I I tiv v vv ------ r i \ \ \ / i 25B (SOIL SUMMARY) yvvv DYKE SILT LOAM \\ of 2%-7% SLOPES PRnPngFn / / / / / / / -- / f f y ✓ � ' i f /' I i f F PROPOSED VERIZON 20' WIDE ACCESS AND UTILITY EASEMENT f / PROPOSED VERIZON 12' WIDE GRAVEL DRIVEWAY / r I / / PROPOSED GRADE LINE I / PROPOSED _— 18" RCP / 10 „ 169 01 161 y ✓ i y' / i / li / / / / / / GRAPHIC SCALE 10 0 5 10 20 40 EROSION & SEDIMENT CONTROL PLAN SCALE: 1" = 10'-0" (IN FEET) 1 INCH = 10 FEET LEGEND ------------------- PROPERTY LINE -- SUBJECT PARCEL -- XXX ------ EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED FENCE PROPOSED LEASE AREA PROPOSED LIMITS OF DISTURBANCE PROPOSED SILT FENCE PROPOSED TREE PROTECTION PROPOSED CONSTRUCTION ENTRANCE NOTE: • A PROPOSED HAY BALE W/ PLASTIC LINING CONCRETE WASHOUT IS REQUIRED TO BE ON SITE. SEE "HAY BALE AND PLASTIC WASHOUT PIT" NOTES ON SHEET ES-2 FOR MORE INFORMATION. CONSTRUCTION MANAGER TO FIELD VERIFY PROPOSED LOCATION. • A SOIL STOCKPILE AREA IS REQUIRED TO BE ON SITE. SEE 4/ES-3 FOR MORE DETAILS. CONSTRUCTION MANAGER TO FIELD VERIFY PROPOSED LOCATION. Know what's below. Call before you dig. w z z LLl z U_ _J a_ a_ Q 0 Q LL 0 w U) CE 0 W z Cl) LLl 0 W W 0 LLl TOTALLY COMMIITTEU NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ 1831 RADY COURT RICHMOND, VA 23222 MIRADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CCC 8 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CCC REV DATE DESCRIPTION BY OF �O G� aj ` 9. JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020' JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION & SEDIMENT CONTROL PLAN EROSION AND SEDIMENT CONTROL NARRATIVE PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS THE CONSTRUCTION OF MONOPOLE TOWER, 90' GRAVEL ACCESS DRIVE, AND FENCED COMPOUND, ALONG WITH ASSOCIATED UTILITIES. THE LEASE AREA OF THE TOWER IS 1,600 SQ.FT.; THE COMPOUND AREA IS 600 SQ.FT.; THE TOTAL DISTURBED AREA IS 3,900 SF. EXISTING SITE CONDITIONS THE EXISTING SITE CONDITIONS CONSIST OF DENSE WOODS, SPARSE WOODLANDS AND OPEN SPACE IN GOOD AND POOR CONDITION. THE GRADE SLOPES TO THE SOUTH WEST TOWARDS GREENWOOD STATION ROAD TO THE WEST AND AN EXISTING GRAVEL ACCESS ROAD TO THE SOUTH. THE PROPOSED ACCESS DRIVE ENTRANCE WILL BE ON THE EXISTING GRAVEL ACCESS DRIVE. THE IS AN APROXIMATELY 6' RIDGE ALONG THE GRAVEL ACCESS DRIVE AND GREENWOOD STATION ROAD. ADJACENT AREAS THE ADJACENT AREAS ARE UNDEVELOPED WOODLANDS AND SINGLE FAMILY RESIDENTIAL HOMES. WITH OPEN PASTURE TO THE NORTH EAST AND SOUTH WEST. THE SITE IS BOARDED BY INTERSTATE 64 TO THE NORTH WEST AND GREENWOOD STATION ROAD TO THE WEST. OFF -SITE AREAS THERE ARE NO PROPOSED OFF -SITE AREAS ASSOCIATED WITH THIS PROJECT. SOILS (25B) DYKE SILT LOAM - 2 TO 7 PERCENT SLOPES CRITICAL AREAS THERE ARE NO CRITICAL AREAS ASSOCIATED WITH THIS PROJECT. ESC MEASURES - STRUCTURAL PRACTICES STRUCTURAL MEASURES TO BE USED ON THE SITE INCLUDE SILT FENCE (VE&SCH SPEC. 3.05), CONSTRUCTION ENTRANCE (VE&SCH SPEC. 3.02), TREE PROTECTION FENCE (VE&SCH SPEC. 3.38), TEMPORARY STOCK PILE (VE&SCH SPEC. 3.30), AND CONCRETE WASHOUT. ALL MEASURES SELECTED ARE STANDARD ESC ITEMS FOR THIS APPLICATION. ANY DISTURBED AREA DENUDED FOR SEVEN DAYS THAT IS NOT IN ACTIVE WORK AREA TO BE TEMPORARILY SEEDED. ESC MEASURES - VEGETATIVE PRACTICES VEGETATION PRACTICES INCLUDE TEMPORARY AND PERMANENT SEEDING (VE&SCH SPEC. 3.31 & 3.32). PERMANENT STABILIZATION 1. UNTIL AN ADEQUATE ROOT SYSTEM IS ESTABLISHED AND IN THE ABSENCE OF ADEQUATE RAINFALL, SODDING (OR WHATEVER VEGETATION IS USED) SHALL BE IRRIGATED AS OFTEN AS NECESSARY TO MAINTAIN MOIST SOIL TO A DEPTH OF 4 INCHES. IN GENERAL, WATERING SHALL BE PERFORMED IN ACCORDANCE WITH THE VESCH. 2. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING IMMEDIATELY FOLLOWING FINISHED GRADING. SEEDING SHALL BE DONE WITH KENTUCKY 31 TALL FESCUE ACCORDING TO STD. AND SPEC. 3.32, PERMANENT SEEDING, OF THE HANDBOOK. EROSION CONTROL BLANKETS WILL BE INSTALLED OVER FILL SLOPES WHICH HAVE BEEN BROUGHT TO FINAL GRADE AND HAVE BEEN SEEDED TO PROTECT THE SLOPES PROPERLY. MULCH (STRAW OR FIBER) WILL BE USED ON RELATIVELY FLAT AREAS. IN ALL SEEDING OPERATIONS, SEED FERTILIZER AND LIME WILL BE APPLIED PRIOR TO MULCHING. IN ACCORDANCE WITH MINIMUM STANDARD #3, PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 3. THE LOCAL VESCP AUTHORITY REPRESENTATIVE SHALL MAKE THE DETERMINATION AS TO WEATHER OR NOT PERMANENT VEGETATION HAS BEEN ESTABLISHED IN ACCORDANCE WITH MINIMUM STANDARD #3. UNDERGROUND UTILITY LINE INSTALLATION: UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: 1. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. 2. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. 3. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. 4. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. 5. DESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. 6. COMPLY WITH APPLICABLE SAFETY REGULATIONS. CONSTRUCTION SEQUENCE AT LEAST 7 DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, THE OWNER/OPERATOR SHALL INVITE ALL CONTRACTORS INVOLVED IN THOSE ACTIVITIES, THE LANDOWNER, ALL APPROPRIATE MUNICIPAL OFFICIALS, THE EROSION AND SEDIMENT CONTROL PLAN PREPARER, AND THE CONSERVATION DISTRICT TO AN ON -SITE MEETING. ALSO, AT LEAST 3 WORKING DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, ALL VIRGINIA CONTRACTORS INVOLVED IN THOSE ACTIVITIES SHALL NOTIFY THE VIRGINIA ONE CALL SYSTEM "MISS UTILITY" INCORPORATED AT 811 FOR BURIED UTILITIES LOCATIONS. EROSION AND SEDIMENT BMPS MUST BE CONSTRUCTED, STABILIZED, AND FUNCTIONAL BEFORE SITE DISTURBANCE BEGINS WITHIN THE TRIBUTARY AREAS OF THOSE BMPS. ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SEQUENCE. EACH STAGE SHALL BE COMPLETED BEFORE ANY FOLLOWING STAGE IS INITIATED. CLEARING AND GRUBBING SHALL BE LIMITED ONLY TO THOSE AREAS DESCRIBED IN EACH STAGE. 1. INSTALL ROCK CONSTRUCTION ENTRANCE AND ALL PERIMETER BMP'S AS SHOWN ON THE PLANS 2. CLEAR TREES AND LIMBS FOR FULL WIDTH OF EASEMENT AND LEASE AREA, GROUND TO SKY. 3. STRIP TOPSOIL FOR THE ACCESS DRIVE AND STORE AT DESIGNATED LOCATIONS AS SHOWN ON THE PLANS OR LOCATION AS AGREED UPON WITH THE CONSTRUCTION MANAGER. 4. ALL DIVERSIONS, SEDIMENT TRAPS, AND STOCKPILES MUST BE SEEDED AND MULCHED IMMEDIATELY UPON CONSTRUCTION. 5. BEGIN GRADING AND INSTALL GRAVEL, ROADSIDE DITCHES, AND CULVERTS WITH OUTLET PROTECTION. 6. STRIP TOPSOIL ACROSS COMPOUND AND STORE AT DESIGNATED LOCATIONS AS SHOWN ON THE PLANS OR LOCATION AS AGREED UPON WITH THE CONSTRUCTION MANAGER. 7. GRADE COMPOUND SITE AND INSTALL GRAVEL. IMMEDIATELY STABILIZE FILL AND CUT SLOPES WITH EROSION CONTROL MATTING OR ROCK. 8. ONCE CONSTRUCTION OF COMPOUND AND ACCESS DRIVE IS COMPLETE, BEGIN CONSTRUCTION OF TOWER AND ASSOCIATED FACILITIES AND UTILITIES AS SHOWN ON THE DRAWINGS. 9. IF CONSTRUCTION IS TERMINATED OR SUSPENDED PRIOR TO CONSTRUCTION COMPLETION, ALL EXPOSED SOIL AREAS SHALL BE SEEDED WITH TEMPORARY SEEDING AND MULCHED IMMEDIATELY. 10. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ALL SEDIMENT AND EROSION CONTROL FACILITIES IN EFFECTIVE WORKING ORDER DURING CONSTRUCTION AND UNTIL ALL EXPOSED SOIL AREAS HAVE BEEN STABILIZED. 11. NO EROSION AND SEDIMENT CONTROL MEASURES CAN BE REMOVED WITHOUT APPROVAL OF THE ENVIRONMENTAL INSPECTOR FOR THE PROJECT. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE, THE 0/RP SHALL STABILIZE ANY AREAS DISTURBED BY THE ACTIVITIES. DURING NON -GERMINATING PERIODS, MULCH MUST BE APPLIED AT THE SPECIFIED RATES. DISTURBED AREAS WHICH ARE NOT AT FINISHED GRADE AND WHICH WILL BE REDISTURBED WITHIN 1 YEAR MUST BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY VEGETATIVE STABILIZATION SPECIFICATIONS. DISTURBED AREAS WHICH ARE AT FINISHED GRADE OR WHICH WILL NOT BE REDISTURBED WITHIN 1 YEAR MUST BE STABILIZED IN ACCORDANCE WITH THE PERMANENT VEGETATIVE STABILIZATION SPECIFICATIONS. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION WHEN IT HAS A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR OTHER PERMANENT NON -VEGETATIVE COVER WITH A DENSITY 'SUFFICIENT TO RESIST ACCELERATED SURFACE EROSION AND SUBSURFACE CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER MOVEMENTS. AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND SEDIMENT BMPS MUST BE REMOVED. AREAS DISTURBED DURING REMOVAL OF THE BMPS MUST BE STABILIZED IMMEDIATELY. GENERAL EROSION AND SEDIMENT CONTROL NOTES: 1. THE OWNER/DEVELOPER MUST NOTIFY THE ALBEMARLE COUNTY AT LEAST 24 HOURS PRIOR TO THE START OF THE CONSTRUCTION IN ACCORDANCE WITH APPLICABLE ALBEMARLE COUNTY ORDINANCES AND POLICIES. 2. THE OWNER/DEVELOPER GRANTS THE RIGHT -OF -ENTRY ON TO THIS PROPERTY TO THE DESIGNATED ALBEMARLE COUNTY PERSONNEL FOR THE PURPOSE OF INSPECTING AND MONITORING FOR COMPLIANCE WITH TITLE 10.01 , CHAPTER 5, ARTICLE 4 OF THE CODE OF VIRGINIA, EROSION AND SEDIMENT CONTROL LAW AND THE DESIGN AND CONSTRUCTION STANDARDS MANUAL SECTION 750.04, 3. ALL EROSION CONTROL MEASURES SHOWN ON THE APPROVED PLAN MUST BE IN PLACE AND INSPECTED AND APPROVED BY THE DEPARTMENT PF PUBLIC WORKS PRIOR TO CLEARING, STRIPPING OF TOPSOIL OR GRADING. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE KEPT ON THE SITE AT ALL TIMES. 5. THE DEVELOPER/DEVELOPERS'S REPRESENTATIVE IS RESPONSIBLE FOR THE INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE ALBEMARLE COUNTY. 6. ALL DISTRIBUTED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL COMPLETE AND ADEQUATE STABILIZATION IS ACHIEVED. 7. WATER MUST BE PUMPED INTO AN APPROVED FILTERING DEVICE DURING DEWATERING OPERATIONS. 8. ALL EROSION AND SEDIMENT CONTROL PRACTICES MUST BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND THE VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS AND TO AMHERST COUNTY DESIGN AND CONSTRUCTION STANDARDS MANUAL. THE DEVELOPER/DEVELOPER'S REPRESENTATIVE WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL PRACTICES AT ALL TIMES. 9. THE DEVELOPERS/ DEVELOPER'S REPRESENTATIVE SHALL INSPECT ALL EROSION AND SEDIMENT CONTROL MEASURES DAILY AND AFTER EACH SIGNIFICANT RAINFALL THE FOLLOWING ITEMS WILL BE CHECKED IN PARTICULAR: a. SILT FENCE BARRIERS WILL BE CHECKED REGULARLY FOR UNDERMINING OR DETERIORATION OF THE FABRIC. SEDIMENT SHALL BE REMOVED WHEN THE LEVEL OF SEDIMENT DEPOSITION REACHES HALF WAY TO THE TOP OF THE BARRIER. b. SEEDED AREAS WILL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RE -SEEDED AS NEEDED. 10. SEDIMENT TRAPPING MEASURES WILL BE INSTALLED AS A FIRST STEP IN GRADING AND WILL BE SEEDED AND MULCHED IMMEDIATELY FOLLOWING INSTALLATION. 11. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZED SHALL BE APPLIED WITH IN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN UNDISTURBED FOR LONGER THAN FOURTEEN (14) DAYS. SEEDING AND SELECTION OF THE SEED MIXTURE SHALL BE IN ACCORDANCE WITH VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK STANDARD AND SPECIFICATION 3.32. ROADS AND PARKING AREAS SHALL BE STABILIZED WITH SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED. 12. ELECTRIC POWER, TELEPHONE, CABLE T.V. AND GAS SUPPLY TRENCHES SHALL BE COMPACTED, SEEDED AND MULCHED WITHIN FIVE DAYS AFTER BACKFILL 13. ALL TEMPORARY EARTH BERMS, DIVERSIONS AND SILT DAMS SHALL BE MULCHED WITHIN FIVE DAYS AFTER GRADING. STRAW OR HAY MULCH IS REQUIRED. 14. DURING CONSTRUCTION, ALL STORM SEWER INLETS SHALL BE PROTECTED BY INLET PROTECTION MAINTAINED AN MODIFIED DURING CONSTRUCTION AS REQUIRED. 15. AT THE COMPLETION OF ANY PROJECT CONSTRUCTION AND PRIOR TO BOND RELEASE, ALL TEMPORARY SEDIMENT CONTROL MEASURES SHALL BE REMOVED. 16. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES WILL BE REMOVED WITHIN 30 DAYS AFTER ADEQUATE SITE STABILIZATION AND AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, AS AUTHORIZED BY THE ALBEMARLE COUNTY INSPECTORS. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES WILL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 17. WHEN SEDIMENT IS TRANSPORTED ONTO A PAVED ROAD SURFACE, THE ROAD WILL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT WILL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING WILL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. 18. AREAS WHICH ARE NOT TO BE DISTURBED WILL BE CLEARLY MARKED BY FLAGS, SIGNS, ETC. 19. RPA AND FLOOD PLAIN LIMITS SHALL BE CLEARLY MARKED IN THE FIELD BY FLAGS, SIGNS, ETC. 20. TREE SAVE AREAS SHALL BE CLEARLY MARKED IN THE FIELD BY ORANGE SAFETY FENCE. APPROPRIATE TREE PRESERVATIONS SIGNS (WATERPROOF) TO IDENTIFY TREE PRESERVATION AREA SHALL BE LOCATED ON TREE PROTECTIONS FENCING (INCLUDES SUPER SILT FENCING) AND SHOULD BE LOCATED ALTERNATE BETWEEN ENGLISH AND SPANISH EVERY 30 FEET. 21. ORANGE SAFETY FENCE MUST BE INSTALLED AROUND ALL SILT TRAPS AND SEDIMENT BASINS. MAINTENANCE 1. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF PRODUCING RAINFALL EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. THE FOLLOWING ITEMS WILL BE CHECKED, IN PARTICULAR: 2. THE SILT FENCE BARRIER WILL BE CHECKED REGULARLY FOR UNDERMINING OR DETERIORATION OF THE FABRIC. SEDIMENT SHALL BE REMOVED WHEN THE LEVEL OF SEDIMENT DEPOSITION REACHES HALF WAY TO THE TOP OF THE BARRIER. 3. THE SEEDED AREAS WILL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RE -SEEDED AS NEEDED. 4. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ECS CONTROLS DURING CONSTRUCTION. 5. INSPECTION TO BE CONDUCTED SHALL BE PER ALBEMARLE COUNTY STANDARDS AND REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS. 6. SILT FENCE SHALL BE CHECKED AFTER EACH MAJOR STORM EVENT OR ONCE EVERY FIVE DAYS. SEDIMENT SHALL BE REMOVED AFTER IT BECOMES 1 /3 HEIGHT OF SILT FENCE. 7. ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL WILL BE CONSTRUCTED ACCORDING TO THE STANDARDS AND SPECIFICATIONS OF THE VIRGINIA SEDIMENT AND EROSION CONTROL HANDBOOK, 3RD ED, 1992. SEED NG / STABILIZATION SPEC E CAT ONS 1. TOPSOIL STOCKPILE PROTECTION A. APPLY GROUND LIMESTONE AT A RATE OF 90LBS. PER 1000 SQ.FT. B. APPLY FERTILIZER (10-20-10) AT A RATE 1 1 LBS. PER 1000 SQ.FT. C. APPLY PERENNIAL RYEGRASS SEED AT 170 LB. PER 1 ACRE. AND ANNUAL RYEGRASS AT 170 LB. PER 1 ACRE. D. MULCH STOCKPILE WITH STRAW OR HAY AT A RATE OF 138 LBS. PER 1000 SQ.FT. E. PROPERLY ENTRENCH A SILT FENCE AT THE BOTTOM OF THE STOCKPILE. 18. TEMPORARY STABILIZATION SPECIFICATIONS A. APPLY GROUND LIMESTONE AT A RATE OF 184 LBS. PER 1000 SQ.FT. B. APPLY FERTILIZER (10-20-10) AT A RATE 11 LBS. PER 1000 SQ.FT. C. APPLY PERENNIAL RYEGRASS SEED AT 170 LB. PER 1 ACRE. AND ANNUAL RYEGRASS AT 170 LB. PER 1 ACRE. D. MULCH STOCKPILE WITH STRAW OR HAY AT A RATE OF 138 LBS. PER 1000 SQ.FT. E. APPLY A LIQUID MULCH BINDER OR TACK TO STRAW OR HAY MULCH. 19. PERMANENT STABILIZATION SPECIFICATIONS A. APPLY TOPSOIL TO A DEPTH OF 5 INCHES (UNSETTLED) B. APPLY GROUND LIMESTONE AT A RATE OF 184 LBS. PER 1000 SQ.FT. AND WORK FOUR INCHES INTO SOIL. C. APPLY FERTILIZER (10-20-10) AT A RATE 11 LBS. PER 1000 SQ.FT. D. APPLY HARD FESCUE SEED AT 20 LBS. PER 1 ACRE. AND CREEPING RED FESCUE SEED AT 20 LBS. PER 1 ACRE. AND PERENNIAL RYEGRASS SEED AT 20 LBS. PER 1 ACRE. AND TALL FESCUE SEED AT 20 LBS. PER 1 ACRE. E. MULCH STOCKPILE WITH STRAW OR HAY AT A RATE OF 138 LBS. PER 1000 SQ.FT. F. APPLY A LIQUID MULCH BINDER OR TACK TO STRAW OR HAY MULCH. GRADING NOTES 1. SOILS USED FOR ROADWAY SUBGRADE MUST BE COMPACTED SO THAT THE MINIMUM DRY DENSITY ACHIEVED EXCEEDS 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY. THE CONTRACTOR MAY ONLY USE CUT MATERIAL AS FILL IF IT CAN BE COMPACTED TO 95% OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY. PROCTOR READING MUST BE INSPECTED AND APPROVED BY A THIRD PARTY DURING ROADWAY CONSTRUCTION. 2. NATIVE TOPSOIL SHALL BE SAVED, STOCKPILED, MULCHED, AND REUSED AS MUCH AS POSSIBLE ON THE SITE. SILTATION FENCE SHALL BE INSTALLED AT THE BASE OF STOCKPILES AT THE DOWNHILL LIMIT TO PROTECT AGAINST EROSION. STOCKPILES WILL BE STABILIZED BY SEEDING AND MULCHING UPON FORMATION OF THE PILES. UPHILL OF THE STOCKPILES, STABILIZED DITCHES AND/OR BERMS WILL BE CONSTRUCTED TO DIVERT STORMWATER RUNOFF AWAY FROM THE PILES. EXCESS CUT SOIL NOT REUSED AS FILL SHALL BE HAULED OFF SITE TO AN APPROVED AND PERMITTED SOIL DISPOSAL SITE AS SOON AS FINAL GRADE HAS BEEN ESTABLISHED.. 3. FOR AN EARTH DISTURBANCE ACTIVITY OR ANY STAGE OR PHASE OF AN ACTIVITY TO BE CONSIDERED PERMANENTLY STABILIZED, THE DISTURBED AREAS SHALL BE COVERED BY A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR OTHER PERMANENT NON -VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION AND SUBSURFACE CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER MOVEMENTS. 4. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 8 INCHES IN THICKNESS. 5. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR ORGANIC MATERIAL THAT WOULD INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS. ANY ROCK GREATER THAN 12" IN ANY DIRECTION SHOULD BE DISPOSED OF AND NOT USED AS FILL. FILL SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES. 6. PLOW, SCARIFY, BENCH, OR BREAK UP SLOPED SURFACES STEEPER THAN 1 VERTICAL TO 4 HORIZONTAL SO FILL MATERIAL WILL BOND WITH EXISTING MATERIAL. IF FILL EXCEEDS 4' IN HEIGHT FROM TOE TO CREST, FILL MUST BE BENCHED AND KEYED IN. SEE DETAIL 4/ES-7 FOR DETAILS. 7. PLACE SOIL FILL ON SUB -GRADES FREE OF ORGANIC MATERIAL, MUD, FROST, SNOW, OR ICE 8. PLACE BACKFILL AND FILL MATERIALS IN LAYERS NOT MORE THAN 8 INCHES THICK IN LOOSE DEPTH COMPACTED BY HEAVY COMPACTION EQUIPMENT, AND NOT MORE THAN 4 INCHES IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HAND OPERATED TAMPERS. 9. UNDER ACCESS ROADS WITH MARGINAL TO EXCESSIVE SLOPES AND MARGINAL SUBGRADE, CLEAR, GRUB AND SCARIFY ROAD AREA. INSTALL ONE LAYER OF GEO-TEXTILE FABRIC (US 160 NW OR EQUIVALENT) AND PIN TO SUBGRADE. INSTALL BASE LAYER, AND TRACK IN WITH A BULLDOZER OR SHEEPSFOOT ROLLER, INSTALL SURFACE LAYER, DRESS ROAD AS REQUIRED AFTER CONSTRUCTION WITH MOTOR GRADER AND COMPACT WITH A VIBRATORY ROAD ROLLER. CL W z z LLJ 0 Q O LL z W f- W Q J z O uj LL Er W rr W z_ C� z W Lu W W U) TM TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ 1831 RADY COURT RICHMOND, VA 23222 M I RADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 106/11/20 I REVISED I Pip 4 106/09/20 I FINAL I CCC 3 105/22/20 I REVISED I cCC 2 04/24/20 REVISED REVISED CCC 1 04/14/20 GCc 0 04/08/20 PRELIMINARY ZDs CCG REV I DATE I DESCRIPTION I BY OF G j� JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020 49- isitSslGN 1Cs JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION & SEDIMENT CONTROLI NOTES HAY BALE AND P LASTI C WASHOUT PIT ' HAY BALE AND PLASTIC WASHOUT PIT TO BE BUILT ABOVE GRADE. THE PLASTIC LINING SHOULD BE MINIMUM 10 W MIL THICKNESS, FREE OF TEARS OR HOLES THAT WOULD ALLOW THE WASHWATER TO ESCAPE. AFTER THE PIT IS LLJ USED TO WASH DOWN THE CHUTES OF MULTIPLE READY MIXED TRUCKS AND THE WASHWATER HAS EVAPORATED OR HAS BEEN VACUUMED OFF, THE REMAINING HARDENED SOLIDS CAN BE BROKEN UP AND REMOVED FROM THE PIT. THIS PROCESS MAY DAMAGE THE HAY BALES AND PLASTIC LINING. IF DAMAGE OCCURS, THE PIT WILL NEED TO BE REPAIRED AND RELINED WITH NEW PLASTIC. WHEN THE HARDENED SOLIDS ARE REMOVED FROM THE PIT. I THE WASTE MATERIAL MUST BE RECYCLED OR DISPOSED OF AT AN APPROVE WASTE FACILITY. LLJ ES W Cn TM CONSTRUCTION OF A SILT FENCE (WITH WIRE S UPPOR T) 1. SET POSTS AND EXCAVATE A 4"X4' 2. STAPLE WIRE FENCING TO THE POSTS. TRENCH UPSLOPE ALONG THE LINE OF POSTS. "�� MIIIYI � I11t11 I�( FLOW 3. ATTACH THE FILTER FABRIC TO THE WIRE FENCE AND EXTEND IT INTO THE TRENCH 4. BACKFILL AND COMPACT THE EXCAVATED SOIL. NOTE: ALL SILT FENCES ARE TO USE 36 INCH FABRIC AND STAKED WITH 2"X2" HARDWOOD STAKES ON 6' CENTERS VESCH 3.05 SILT FENCE STANDARD FILTER FABRIC FENCE ES-3 NTS SF TYPICAL ®RIENTA TION 0F TREA TMENT — 1 �S OIL STABILIZATION BLANKET) (4HAI I nW ON SHALLOW SLOPES, STRIPS OF NETTING PROTECTIVE COVERINGS MAY BE APPLIED ACROSS THE SLOPE. BERM WHERE THERE IS A BERM AT THE TOP OF THE SLOPE, I 1 1-11— BRING THE MATERIAL OVER THE BERM AND ANCHOR IT BEHIND THE BERM.II=111— ' fit filFH ON TS EF SLOPES, APPLY PROTECTIVE COVERING PARALLEL TO THE DIRECTION OF FLOW AND ANCHOR SECURELY. 4 :.:...:... BRING MATERIAL DOWN TO A LEVEL AREA BEFORE TERMINATING THE INSTALLATION. TURN THE END UNDER 4" AND STAPLE AT 12" INTERVALS. .. 12• IN DITCHES, APPLY PROTECTIVE COVERING PARALLEL TO THE DIRECTION OF FLOW. USE CHECK SLOTS AS REQUIRED. AVOID JOINING MATERIAL IN THE CENTER OF THE DITCH IF AT ALL POSSIBLE. STONE CONSTRUCTION ENTRANCE 70' MIN. EXISTING PAVEMENT A 3' ,( 5:1 Fa P FILTER CLOTH 6" MIN. A MOUNTABLE BERM (OPTIONAL) 7 SIDE ELEVATION EXISTING GROUND 12' MIN. 70' MIN. B WASHRACK F— (OPTIONAL) VDOT *1 I I Y� POSITIVE DRAINAGE COURSE AGGREGATE B TO SEDIMENT TRAPPING DEVICE * MUST EXTEND FULL WIDTH OF INGRESS AND EGRESS PLAN VIEW OPERATION i"L' MIN. SECTION A -A KLIW I-IKULD LLIIVLK[.I L SECTION B-B 10' MIN. 10, MIN. EXISTING PAVEMENT 10' MIN. DKMIIV Jr HI..0 VESCH 3.02 TEMPORARY CONSTRUCTION ENTRANCE ROCK CONSTRUCTION ENTRANCE C E NTS TYPICAL TREA TMENT _ I (SOIL STABILIZATION BLANKET) INSTALLATION CRITERIA ANCHOR SLOT NOTES APPROXIMATELY 200 STAPLES REQUIRED PER 100 SQ. YDS. OF MATERIAL ROLL. ANCHOR SLOTS, JUNCTION SLOTS dt CHECK SLOTS TO BE BURIED 6" TD 12". 12 MAX. 4:1 OR FLATTER 4A G MAX. STEEPER THAN 4:1 `I JUNCTION SLOT EDGE AND END JOINTS I I I I I I I I I I CHECK SLOT* TO BE SNUGLY ABUTTED I (JUTE MESH WILL HAVE I TERMINAL FOLD STAPLED LAP JOINT IN I LIEU OF EDGE JOINT) LAP JOINT 2" MIN, I I I I I I TAMP FIRMLY (JUTE MESH ONLY) I I I I ANCHOR SLOT 5' MAX. 4:1 OR FLATTER 3' MAX. STEEPER THAN 4:1 I I I 2" I I TO 12" I I I I 1 I I I i t I I I I *CHECK SLOT E No --�I--,-1" TOFIRMLY TAMP CHECK SLOT I I I I Il i T—i vl� AR '� VAR. 6• TO z' C TO 8* MIN. PLAN VIEW STAPLING DIAGRAM O NREO STAPLE FORMED FROM N0.11 STEEL WIRE. *CHECK SLOTS AT MIN, 8" STAPLE MIN. LENGTH FOR SANDY SOIL. INTERVALS; NOT EO.'D WITH ALL JUNCTION SLOT 2 FIRMLY TO 12 12" TERMINAL FOLD ..... ....... r2.. TABLE 3.32-C SITE SPECIFIC SEEDING MIXTURES FOR APPALACHIAN/MOUNTAIN AREAL Total Lbs. Minimum Care Lawn Per Acre - Commercial or Residential 200-250 lbs. - Kentucky 31 or Turf -Type Tall Fescue 90-100% - Improved Perennial Ryegrass * 0-10% - Kentucky Bluegrass 0-10% High -Maintenance Lawn Minimum of three (3) up to five (5) varieties of bluegrass from approved list for use in Virginia. 125 lbs. General Slope (3:1 or less Kentucky 31 Fescue 128 lbs. - Red Top Grass 2 lbs. Seasonal Nurse Crop * * 20 lbs. 150 lbs. Low -Maintenance Slope (Steeper than 3:1) - Kentucky 31 Fescue 108 lbs. - Red Top Grass 2 lbs. - Seasonal Nurse Crop * * 20 lbs. Crownvetch * * * 20 lbs. 150 lbs. * Perennial Ryegrass will germinate faster and at lower soil temperatures than fescue, thereby providing cover and erosion resistance for seedbed. * * Use seasonal nurse crop in accordance with seeding dates as stated below: March, April through May 15th .................... Annual Rye May 16th through August 15th .................... Foxtail Millet August 16th through September, October ............. Annual Rye November through February ...................... Winter Rye *** If Flatpea is used, increase to 30 lbs./acre. All legume seed must be properly inoculated. Weeping Lovegrass may also be included in any slope or low - maintenance mixture during warmer seeding periods; add 10-20 lbs/acre in mixes. VESCH 3.32 PERMANENT SEEDING s PERMANENT SEEDING �-3NTs TABLE 3.31-B ACCEPTABLE TEMPORARY SEEDING PLANT MATERIALS "QUICK REFERENCE FOR ALL REGIONS" Planting Dates Sept. 1 - Feb. 15 Feb. 16 - Apr. 30 May 1 - Aug 31 Species 50/50 Mix of Annual Ryegrass (Lolium multi-florum & Cereal (Winter) Rye (Secale cereale) Annual Ryegrass (Lolium multi-florum) German Millet (Setaria italica) PS Rate lbs. acre 50 - 100 60 - 100 50 0 LID] IW064we] IRS 111r11 VJ PLAN r� 18" SILT FENCE OR 8" SILT SOXX (OR GREATER) n O SEED W/ VDOT FORMULA "C" IF NOT USED WITHIN 20 DAYS. 18" SILT FENCE OR 8" SILT SOXX (OR GREATER) NOTES: ELEVATION 1. INSTALL SILT FENCE DOWNSLOPE OF AREA OF STOCKPILE. 2. PLACE STOCKPILE IN AREAS SHOWN ON EROSION CONTROL PLAN WITHOUT BLOCKING NATURAL DRAINAGE PATTERNS. 3. FOLLOW DIMENSIONS SHOWN ABOVE. HEIGHT SHOULD NOT EXCEED 35 FT. SIDE SLOPES SHOULD NOT BE STEEPER THAN 2(H):1 (V). 4. SEED IMMEDIATELY IF MATERIAL IS NOT TO BE USED WITHIN 20 DAYS. FOLLOW "SEEDING, FERTILIZATION SCHEDULE & SPECIFICATIONS." 5. LOCATION(S) AND SIZES) OF SOIL STOCKPILES ARE APPROXIMATE AND SHALL BE ADJUSTED PER FIELD AND CONSTRUCTION SEQUENCE CONDITIONS. CONTRACTOR SHALL VERIFY REQUIRED SIZE(S). REQUIREMENTS FROM THE STANDARDS DETAIL MUST BE FOLLOWED FOR STOCKPILES. TOPSOIL STOCKPILE AND MAINTENANCE NTS TOPSO L SPEC F CAT ONS 1. TOPSOIL SPECIFICATIONS A. THE CONTRACTOR SHALL FURNISH ALL LABOR, SUPERVISION, MATERIAL (EXCEPT AS HEREIN PROVIDED), TOOLS EQUIPMENT, SUPPLIES, AND SERVICES; AND, SHALL PERFORM ALL WORK NECESSARY FOR PROVIDING (TYPE B AS NECESSARY) AND APPLYING TOPSOIL IN ACCORDANCE WITH THE REQUIREMENTS OF THESE SPECIFICATIONS AND IN CONFORMITY TO THE DEPTHS AND LIMITS SHOWN ON THE DRAWINGS OR AS ESTABLISHED BY THE OWNER. B. PRIOR TO USE OR PLACEMENT, THE CONTRACTOR SHALL SUBMIT CERTIFICATIONS OF SOIL TESTS FOR APPROVAL. SOIL TESTS SHALL BE PROVIDED AT THE RATE OF ONE TEST PER 10,000 SQUARE FEET OF DISTURBED AREA. C. UNLESS OTHERWISE DIRECTED BY THE OWNER, AREAS DESIGNATED TO RECEIVE TOPSOIL SHALL BE GRADED, SHAPED, AND THEN SCARIFIED OR TILLED BY DISKING, HARROWING, OR OTHER APPROVED METHODS TO A DEPTH OF APPROXIMATELY 2". TOPSOIL SHALL BE APPLIED ONLY WHEN THE SUBSOIL IS IN A LOOSE, FRIABLE CONDITION. D. THE CONTRACTOR SHALL PROTECT BENCHMARKS, UTILITIES, AND EXISTING TREES, SHRUBS, AND OTHER LANDSCAPE FEATURES DESIGNATED FOR PRESERVATION WITH TEMPORARY FENCING OR BARRICADES SATISFACTORY TO THE OWNER. E. SUBSOIL ON SLOPES THAT HAVE BEEN HORIZONTALLY GROOVED IN ACCORDANCE WITH THE DRAWINGS SHALL NOT BE LOOSENED. F. THE LOOSE DEPTH OF THE CLASS OF TOPSOIL SHALL BE NO LESS THAN 4" (NOT LESS THAN 6" IN MEDIANS: AND SHALL BE SUFFICIENT TO ALLOW THE AREA TO CONFORM TO THE ELEVATIONS SHOWN ON THE DRAWINGS AFTER TOPSOIL SETTLES. IN NO CASE SHALL THE CONSOLIDATED FINISH ELEVATION OF TOPSOIL EXCEED THE ELEVATION OF ADJACENT STRUCTURES. CONSOLIDATED ELEVATION SHALL BE FLUSH WITH THE ADJACENT STRUCTURES. G. AFTER TOPSOIL HAS BEEN APPLIED, LARGE CLODS, HARD LUMPS, AND STONES MORE THAN 1 " IN THE GREATEST DIMENSION, BRUSH, ROOTS, STUMPS, LITTER, AND FOREIGN MATERIAL SHALL BE REMOVED FROM THE AREA. WHEN THE OPERATION IS COMPLETE, THE AREA SHALL BE IN A CONDITION TO RECEIVE SEED, SOD, OR PLANTS WITHOUT FURTHER SOIL PREPARATION. AREAS SHALL BE STABILIZED WITHIN 15 DAYS AFTER TOPSOIL IS APPLIED. H. THE CONTRACTOR SHALL BE REQUIRED TO BACKFILL ALONG EDGES OF CURBS, SIDEWALKS AND ENTRANCES WHERE SETTLEMENT HAS OCCURRED AND RESHAPE AND RESLOPE, WHERE DIRECTED, PRIOR TO PLACEMENT OF TOPSOIL AS WELL AS TO ADD ADDITIONAL TOPSOIL AS REQUIRED DUE TO SETTLEMENT OR EROSION AT NO ADDITIONAL COST TO THE OWNER. ■.I MAX CLEARIN NO STANDARD CONSTRUCTION NUMBER NOTES: T _ _ 1 1. THE TREE PROTECTIVE BARRIER MUST CONSIST OF ORANGE SAFETY FENCING, NOT LESS "� VESCH 3.31 TEMP 0 RARY SEEDING THAN THREE FEET HIGH AND SUPPORTED BY WOOD/METAL POLES. 2. THE TREE PROTECTIVE BARRIER WILL NEED TO REMAIN IN PLACE THROUGHOUT CONSTRUCTION. (6'TEMPORARY SEEDING 3. APPROVAL OF TREE PROTECTIVE BARRIER WOULD NEED TO OCCUR PRIOR TO THE ISSUANCE NTS TS OF A BUILDING PERMIT AND FINAL SITE PLAN APPROVAL. ES-3 VESCH 3.38 TREE PRESERVATION AND PROTECTION VESCH 3.36-1 SOIL STABILITY & BLANKET MATTING BM 5 SOIL STABILITY & BLANKET MATTING 7 TREE PROTECTION FENCE TP NTS �-3NTS ES-3 z TOTALLY COMMITTED. z w NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 a veri on,/ J a Q 1831 RADY COURT RICHMOND, VA 23222 z M I RADOR FARM O Q VERIZON RAWLAND GREENWOOD STATION ROAD o (JUST SOUTH OF 1-64) LU GREENWOOD, VA 22943 u) ALBEMARLE COUNTY 0 CL U LL z U) LL 0 J z O w L- (1 LLJ w 0 W -1 w LLJ w -17 co REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CCC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CCC REV DATE DESCRIPTION BY f-ee� OF �'1� Ie JOHN A. DAUGHTREY III Lic. No. 0402052122 �o, 06/11/2020 0NA1_. JOHN A. DAUGHTREY III, P.E. I VA PROFESSIONAL ENGINEER LIC. #052122 EROSION & SEDIMENT CONTROL DETAILS ES-3 TM EXISTING 3' GRADE GRASS LINED DITCH 3' WITH E&S BLANKET MATTING (TREATMENT 2) 3% 3% 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ):0 0 0 0 0 0 0 O� 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N 0 0 0 0 C 0 0 0 1 coo 0 0 0 0 0 -C�I- GEOTEXTILE (SEE NOTE) 3' 3' 3.7 1 f 3' 6" - - 3' 6" - 3' 6" -I- 3' 6" --------- SURFACE COARSE: BASE COARSE: COMPACTED 6" DEPTH OF FULLY GRADED CRUSHED 1 " STONE 4" DEPTH OF COARSE AND SMALLER MIXED WITH DIRT AND FINES SUBGRADE AGGREGATE 2"-3" STONE (CRUSHED AGGREGATE BASE COARSE OR CABC). (AASHTO #5 OR RAILROAD BALLAST) NOTES: 1. SUBGRADE AND FILL SHALL CONSIST OF CLEAN SOIL. NO DELETERIOUS MATERIALS OR ORGANICS TO BE USED. FREE OF FROZEN PARTICLES, ORGANIC MATTER, CLAYED MATERIAL AND ROCK PARTICLES GREATER THAN 12" IN ANY DIRECTION. 2. REMOVE ALL TOPSOIL AND ORGANICS BEFORE COMMENCING ACCESS ROAD FOR A MIN. DEPTH OF 12". 3. DITCH 3.1.DITCH SHALL BE CONSTRUCTED FREE OF SEDIMENT, TREE ROOTS, STUMPS OR OTHER PROJECTIONS THAT WILL IMPEDE NORMAL CHANNEL FLOW AND/OR PREVENT GOOD LINING TO SOIL CONTACT. 4. WOVEN GEOTEXTILE: APPROVED PRODUCTS ARE US FABRICS: US 200 AND TENCATE: 160N. CONTRACTOR MAY SUBMIT DESIGN ALTERNATIVE. PROPOSED GRAVEL DRIVE TYPICAL SECTION NTS FILL SLOPE SEEDED AND MULCHED RIP RAP OUTLET PROTECTION (SEE DETAIL) \ F 1114 I"I - /1 A EXISTING SUBGRADE DOWNSTREAM BLOCK (ENSURE WATER FLOWS INTO CULVERT) :161113 SECTION VIEW z �ADTW rn\IGD 1 � 1 o lL-1 1.5' MIN. CULVERT HDPE OR RCP 1 %-15% SLOPE (SIZED BY DESIGN) PE OR RCP -15% SLOPE (SIZED BY DESIGN) ILL AND HAND TAMP WITH CLEAN, ILAR MATERIAL E DIA ('3- PIPE BEDDING DETAIL ES-4 NTs EXISTING GRADE 1* 2. Ed Al - (6' MIN) J PLAN VIEW Q NOTES: 1. REMOVE TOPSOIL AND PLACE GEOTEXTILE FABRIC PRIOR TO PLACING STONE. 1.1. WOVEN GEOTEXTILE: APPROVED PRODUCTS ARE US FABRICS: US 250 AND TENCATE: MIRAFI 550X. CONTRACTOR MAY SUBMIT DESIGN ALTERNATIVE AS OUTLINED IN THE AMERICAN TOWER MASTER SPECIFICATIONS. 2. ALL APRONS SHALL BE CONSTRUCTED TO THE DIMENSIONS SHOWN. TERMINAL WIDTHS SHALL BE ADJUSTED AS NECESSARY TO MATCH RECEIVING CHANNELS. 3. EXTEND RIPRAP ON BACK SIDE OF APRON TO AT LEAST 1/2 DEPTH OF PIPE ON BOTH SIDES TO PREVENT SCOUR AROUND THE PIPE. RIPRAP APRON OUTLET THICK. LENGTH INITIAL END N0. SIZE Rt La WIDTH WIDTH (D50) (IN) (FT) 3D; (FT) OP-1 6" 12 10 5 15 VESCH 3.1 8- 1 OUTLET PROTECTION OUTLET PROTECTION DETAIL OP NTS rr w z 0 z w 0 Q 0 w z w H- U) rr O U w z U) w 0 n C!) z O CO U) w ILL m w rr W w z_ C� z w w J w w U) rr w m -17 w w 0 TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 veri on,/ 1831 RADY COURT RICHMOND, VA 23222 M I RADOR FARM VERIZON RAWLAND GREENWOOD STATION ROAD (JUST SOUTH OF 1-64) GREENWOOD, VA 22943 ALBEMARLE COUNTY REVISIONS 5 06/11/20 REVISED PJP 4 06/09/20 FINAL CCC 3 05/22/20 REVISED CCC 2 04/24/20 REVISED CCC 1 04/14/20 REVISED CCC 0 04/08/20 PRELIMINARY ZDs CGC REV I DATE I DESCRIPTION I BY �LT H O p t'1� ,K,XA e <t� �' cl—� �;;' JOHN A. DAUGHTREY III Lic. No. 0402052122 06/11/2020 A- `ls- tWA1_. V4 j�� JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION & SEDIMENT CONTROL DETAILS II I ES-4