HomeMy WebLinkAboutSDP202000044 Review Comments Final Site Plan and Comps. 2020-06-22Christopher Perez From: Dyon Vega <DVega@rivanna.org> Sent: Thursday, June 18, 2020 3:49 PM To: Christopher Perez Cc: vfort@rivanna.org; Richard Nelson Subject: 2415 Ivy Rd commercial redevelopment plans review Attachments: PID 06000-00-00-025AO (JPA Towers) - NK.pdf CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Chris, RWSA has reviewed the Initial Site Plan for 2415 Ivy Road Commercial Redevelopment Plans dated 5/11/2020 by Collins engineering and has the following comments. General comments: 1. RWSA would like more information on the proposed use of the manufacturing space and estimated sewer flows to determine if a sewer flow capacity request will be required prior to final site plan approval. Sheet 3 1. Please show RWSA new water line easement (attached, Instrument No. 202000005303) on the western boundary of the parcel. Also show on all relevant sheets. 2. In the Utility notes on this sheet, note that 1.5' of vertical separation is required between RWSA sewer line and any other utilities. 3. Include the following RWSA sewer connection notes on this sheet: Sewer Connection Add the following note to the utility plan sheet: All connections to RWSA manholes shall be watertight and made with a flexible rubber boot. All coring methods, the coring contractor and all materials for construction shall be approved by RWSA in writing prior to construction. RWSA Engineering Staff shall be present for all cores into the manholes. Bypass pumping may be required at the sole discretion of RWSA staff. Grouting of the manhole bench or interior may be required, at the sole discretion of RWSA staff, for a smooth transition of flow. Existing manholes shall be backfilled to original grade to the satisfaction of RWSA. Contact RWSA Engineering a minimum of 3 business days in advance to schedule a core of a manhole. Sheet 5 (which is labeled sheet 6): 1. No trees permitted within sanitary sewer easement. Sheet 8/9: 1. Label RWSA Sewer Manhole on Sanitary lateral Profile. 2. Our records show the sanitary sewer manhole invert to be approximately 558.45. Inverts need to be surveyed and called out in the profile and the 6" tie-in needs to be made at the bench. 3. Please provide a road profile for the connector road to show the grading over the VCP sewer line. Let me know if you have any questions. Thanks, Dyon Vega Civil Engineer RIVANINA WATER SEWERAUTHOITY Rivanna Water & Sewer Authority (434) 977-2970, Ext. 170 695 Moores Creek Lane Charlottesville, VA 22902 www.rivanna.org