Loading...
HomeMy WebLinkAboutSDP202000039 Plan - Revision 2020-06-23MAJOR SITE PLAN AMENDMENT LEGEND EXISTING NEW DESCRIPTION BOUNDARIES BENCHMARK SITE PROPERTY LINE - - ADJACENT PROPERTY LINE BUILDING SETBACK PARKING SETBACK SITE TEXT 10 10 PARKING COUNT NS NS NAIL SET TOPOGRAPHY INDEX CONTOUR - - - - - - - - INTERVAL CONTOUR 150 SPOT ELEVATION JC1WTN TOP OF CURB ELEVATION 1 I T'i'a TOP OF WALL ELEVATION 158W BOTTOM OF WALL ELEVATION STREAM - STREAM BUFFER 100 YEAR FLOODPLAIN BUILDING BUILDING RETAINING WALL STAIRS EDGE OF PAVEMENT ROAD CENTERLINE FRONT OF CURB BACK OF CURB CG-12 TRUNCATED DOME SIDEWALK BIKE PARKING HANDICAP ACCESSIBLE AISLE HANDICAP PARKING MATERIAL °k CONCRETE RIPRAP ASPHALT EC-2 MATTING EC-3 MATTING WETLAND ---------- TR E E L I N E X X FENCE UTILITY UTILITY POLE m m GUY WIRE oHu oHu OVERHEAD UTILITY UGU UGu UNDERGROUND UTILITY STORM O O STORM MANHOLE q q DROP INLET STORM SEWER RD ROOF DRAIN SANITARY O O SANITARY MANHOLE SANITARY SEWER MAIN S S SANITARY SEWER LATERAL WATER W W WATER LINE O O WATER METER 0 WATER METER VAULT t FIRE HYDRANT FIRE DEPARTMENT CONNECTION GAS GAS GAS LINE EASEMENTS CONSTRUCTION GRADING ACCESS SIGHT DISTANCE UTILITY STORMWATER FACILITY MAINTENANCE STORMWATER ACCESS DRAINAGE SANITARY WATERLINE GASLINE NOTE: 1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOWN. OWNER/DEVELOPER Malloy Properties III LLC C/O Malloy Companies LLC 2070 Seminole Trail Charlottesville, Virginia 22901 PLAN PREPARATION Shimp Engineering, P.C. 912 East High Street Charlottesville, VA 22903 (434) 227-5140 ZONING EC - Entrance Corridor HC - Highway Commercial Managed Steep Slopes Overlay Area SP201900011 (awaiting approval) permitting vehicle storage and outdoor sales/storage/display use on the site MAGISTERIAL DISTRICT Rio SOURCE OF TITLE DB 4863 P 467-471 SETBACKS Front minimum: 10' Front maximum: None Side and rear minimum: Any primary structure shall be constructed and separated in accordance with the current edition of the Building Code. Side and rear maximum: None BUILDING HEIGHT Existing building height is 1-story, approximately 15 feet. SOURCE OF BOUNDARY AND TOPOGRAPHY Boundary is based on field survey by: Roger W. Ray & Assoc., Inc. Provided on 03/29/2016 Topographic survey with two foot (2') contours provided by: Bell Land Surveys Field Verified by Shimp Engineering staff March 4, 2020. BENCHMARK Datum for topography is NAVD 88 FLOODZONE These parcels do not lie within a FEMA flood zone as defined on FIRM map 51003CO279D, dated February 4, 2005. RESERVOIR WATERSHED This site is not within a watershed of a public water supply. WATER & SANITARY SERVICES This project lies within the ACSA jursidictional area for both water and sewer. No connections to the remaining warehouse are proposed at this time. FIRE MARSHAL'S NOTES 1. A knox box is required. Location is to be coordinated with the fire marshal's office. 2. ISO Needed Fire Flow = 1,125 gpm. DRAFT CONDITIONS PER SP201900011 1. Use of this site must be in general accord with the concept Ian "Special Use Permit Concept Plan SP201900011 Malloy Ford Concept Plan 9 P pp Y p Sheet 4 of 7" last revised March 24, 2020, as determined by the Director of Planning and the Zoning Administrator. To be in general accord with this plan, development and use of the site shall reflect the general size, arrangement and location of the vehicle display and storage areas. Permitted modifications may include those required by the ARB, those necessary to satisfy the conditions of this special use permit, and additional landscaping/screening approved by the Site Plan Agent. 2. Vehicles must be displayed or stored only in areas indicated for display or storage on the plan entitled "Special Use Permit Concept Plan SP201900011 Malloy Ford Concept Plan Sheet 4 of 7" last revised March 24, 2020 (the Concept Plan). 3. Vehicles for display must be parked in striped parking spaces. 4. Vehicles must not be elevated anywhere outside of a building on site. 5. Final site plan approval is subject to ARB approval of the lighting plan (submitted with the site plan). Maximum height of new pole lights (including bases and fixtures), must not exceed 20'. Maximum light levels must not exceed 22.8 footcandles at the ground in the display lot and 20 footcandles in all other locations. 6. Final site plan approval is subject to ARB approval of the landscape plan (submitted with the site plan). Landscaping shown on the plan may be required to be in excess of the minimum requirements of the ARB guidelines, Albemarle County Code 18-32.9, or both, to mitigate visual impacts of the proposed use, and must include, but not be limited to, the landscaping shown on the Malloy Ford Landscape Plan C1 of 1 revised March 24, 2020. 7. A boundary line adjustment to add the portion of 45-112131 on which parking is shown to parcel 45-68A must be approved prior to final site plan approval. MAJOR SITE PLAN AMENDMENT SUMMARY The purpose of this amendment is to demolish a portion of the existing building on TMP 45-68A and replace it with a parking lot area for vehicle storage and display. A portion of the parking lot area encroaches on existing TMP 45-112131; therefore a boundary line adjustment will be prepared prior to the approval of this amendment. The new boundary line will be offset six feet from the back of proposed curb. This amendment proposes more landscaped area than previous conditions, providing both visual and environmental benefits to the site. Due to the added landscaped area, stormwater runoff will be reduced such that no additional detention is required. Stormwater will be piped to an existing storm system on site at a lower flow rate than in predevelopment conditions, so as not to overwhelm the system. Nutrient credits will be purchased in the amount of 0.01 Ibs/yr to satisfy the remaining water quality treatment requirements. EXISTING USE Vacant Building PROPOSED USE Motor Vehicle Sales/Storage and Outdoor Sales/Storage/Display LAND USE SCHEDULE EXISTING Area % Building 39,216 SF 43.7% Pavement 36,111 SF 40.2% Sidewalk 0 SF 0% Open Space 14,407 SF 16.1 % Total= 89,734 SF (2.06 ac.) PROPOSED Area % Building 9,120 SF 10.2% Pavement 41,363 SF 46.1% Sidewalk 0 SF 0% Open space 39,251 SF 43.7% Total= 89,734 SF (2.06 ac.) PARKING SCHEDULE Parking required: Motor vehicle sales - one space per 1,500 sq ft of display area Approximately 27,750 sq ft outdoor sales/storage/display area 27,750 sf/ 1500 sf= 18.5 19 customer spaces required Parking provided: 19 customer spaces, including 1 van accessible HC space 107 sales/storage/display spaces SIGNS All signs and pavement shall conform with the latest edition of the MUTCD Guidelines. A sign permit must be issued in accordance with the Albemarle County Sign Regulations prior to placement of any signs on -site. Contractor shall provide handicap signs as shown on plan. GENERAL NOTES 1. The information and data shown or indicated with respect to the existing underground utilities at or contiguous to the site are based on information and data furnished to the owner and engineer by the owners of such underground facilities or others. The owner or engineer shall not be responsible for the accuracy or completeness of such information or data. The contractor shall have full responsibility for confirming the accuracy of the data, for locating all underground utilities, for coordination of the work with owners of such underground utilities during construction, for the safety and protection thereof and repairing any damage thereto resulting from the work. All of these conditions shall be met at no additional cost to the owner. The contractor shall contact "Miss Utilities" of Virginia at 1-800-552-7001 prior to the start of work. 2. When working adjacent to existing structures, poles, etc., the contractor shall use whatever methods that are necessary to protect structures from damage. Replacement of damaged structures shall be at the contractor's expense. 3. The contractor shall be responsible for protecting all existing site structures from damage and coordinating work so that the owner can make necessary arrangements to modify/protect existing structures from damages. 4. The contractor shall be responsible for notifying all utility owners, adjacent land owners whose property may be impacted and the Virginia Department of Transportation prior to completing any off -site work. 5. Contractor shall notify and coordinate all work involving existing utilities with utility owners, at least 72 hours prior to the start of construction. 6. Contractor shall immediately report any discrepancies between existing conditions and contract documents to the owner and engineer. 7. Contractor shall submit for the approval of the owner submittals of all specified materials listed in the plans, to include shop drawings, manufacturer's specifications and laboratory reports. the owner's approval of submittals will be general and will not relieve the the contractor from the responsibility of adherence to the contract and for any error that may exist. 8. All bare areas shall be scarified, limed, fertilized, seeded and mulched. 9. All trees, saplings, brush, etc. shall be removed from within the right of way and the drainage easements. 10. Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. 11. Retaining walls require separate building permits. 12. All water service lines, sanitary laterals, and sprinkler lines must be visually inspected by the Albemarle County Building Department from the main to the structure. 13. Accessible parking spaces, access isles, and accessible route shall be installed in accordance with ICC ANSI A117.1-09. 14. All roof drains shall discharge in a manner not to cause a public nuisance and not over sidewalks. ITE Trip Generation Use Cade Independent Variable (IV) AM PM In Out Total In Out Total Automobile Sales (New) 840 1000 Sq. Ft. GFA - 9 10 9 19 11 13 24 MALLOY FORD S D P2020-39 ; AMENDMENT TO SDP 1987-6 TAX MAP 45, PARCEL 68A TAX MAP 45, PARCEL 112131 ALBEMARLE COUNTY, VIRGINIA VICINITY MAPSCALE : 1°=1000' Sam s Club 7 ✓PLY + atrzr, r,nn•�� u mansky Hondd� aNeppy Nalls Walmartl Supercemer aN Q IQ a. Speedway subway Pesialoa^rs 1.10 ® §` Pn Ce Hyu/ngdai '"c1 Jlrn Pere Chevrolet p Y Hlgh tech 51gryS ROUTE 29 Malloy Ford otin r� ® Char CharloxesvllleA SITE - . �Xen Farmerl� Albemarle SPCA 7 Art, A4ques Advravr, 4 AMP Xeg4er's Lanes 4 Lowe's Home Improvement Agnur Hun [1 Elementary School Y Krorwr T rrgplcal Smnnrhie Cafe Crilck-fll A SHEET INDEX C1 COVER C2 EXISTING CONDITIONS C3 BOUNDARY LINE ADJUSTMENT C4 SITE PLAN C5 GRADING PLAN C6 UTILITY PLAN C7 LANDSCAPE PLAN C8 LIGHTING PLAN C9 SITE DETAILS & PROFILES APPROVALS rmnki ��e D Current Development Planner Date Current Development Engineer Date Architectural Review Board Date Fire Official Date Building Official Date Albemarle County Service Authority Date Virginia Department of Transportation Date IMAGE PROVIDED BY GOOGLE MAPS SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM o� F Grp v . SHIMP Y Lic. .41183 �2�2� wAr �O xoNa�. V, MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. COVER 19.057 C1 c_ --— 502- oyG / / OH OHU OHU OHU OHU 0 °tip c �° z v v ° o�o� T. M 4 5 =112 A tiG oN�� ��ALLOY PR_QPERTIFZ II` ° - -- - 498 - MAEL01'COMPA/NIE� / Aso 4863 PG/4 �0 ZONED: HC I 494 I I \ \ I \ I I I I i \\\ 490 I ' \ I I 488 — I / \ / I / 486 T. M 45- t1-2B 1 1 \ / MALLOY PROPERTIES III C/O o \ MALLOY COMPANIES EEC ' ti° vv v v DB 4863 PC 471 �' ; 'I \\ \\ \\\ONED: HC �� I / CURRENT- 4SE-/��ANT I I � 484_ I . O \\ I I I \ MANAGED SLOPES 1 1 8 I I LIMITS OF DISTURBANCE I I — — 1 1 480 �O (j) � co \ \ I 0 _ C() v \ \ c)o �n 1 `7 I c-qo PORTION OF BUILDING TO REMAIN I I I I I --- -- -- -- -- --° ° \ T.M 45 68A �. MALLOY PROPERTIES III C/O J • • 20 40 •• GraphicScale: • MALLOY COMPANIES EEC.°k' ' l DB 4863 PG 467k}.k k ZONED: HC \.\\. / °°° �Q0 k I CURRENT USE: COMMERCIAL }�'`' .°I xX � } . / I o`�� 0 N m �Q I I I 0(D 3 r Lo T. M 45 68C1 )RTION OF BUILDING PAD TO REMAIN - ' I CD � cD � )T INCLUDED IN LIMITS OF DISTURBANCE MALLOY PROPERTIES III C/O I MALLOY COMPANIES EEC ' DB 4863 PG 461 / ZONED: HC ,' PAIRKING ING ARtA k TO BE / ` I II °° °° CURRENT USE: COMMERCIAL 0 REMOVED0 . \ C/) / / \ ( � 30,096 SF BUILDING P40 I \ _ PORTION TO BE REM�D, I IIIIIIIIIII 1 p PORTION TO REMAIN & BE BUILT UP KI x xx x -o XISTING TREES TBR� DISTURBED NEW- T nI LANDSCAPE ISLANDS 4 76 "u - � CD FT] = D - (F1 CA ----- _-- ----__ O 472-----0 D D z I rT� D 0-) z �eU , In' \ \ °iG" \ --—468------y< -- — — — — ---__— — (f) cJ C) --- 466—---------\ - — -EXISTING PARKING ARE - TO BE R MOVE — — — o \ \ °0 \ �C)l �} o K: \ N � \ \ n — o \ \ \ \ C ) — — — — — G \ — X \ \ I- —_ ____—_— __�_ _\- - OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU � OHU HU OHU OHO\ _ — — — — / \ OHU OHU U OHU OHU OHU H HU OHU OH� � 02 — j � ° HU OHU OHU U ^�^ HU OHS 0 — HU U�=ak11��6H1t— —� OH 464_ — \ _ J — _ vC� OHU F9 HU — 0 OHVI.. t 0 H nj OHU' , Omu a O \ W Okdli HU Oki U . OHIJ SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM O � SHIlVIP > Lic. 4 183 wd �o G� ��SSIONAL E1`1 MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. 00 19.057 _ < ° I 1 cj�' yG Q EXISTING CONDITIONS u� Ln ��' U.S. ROUTE 29 �'' X N c� 0-)/ 24 JOINT SEMINOLE TRAIL D 1 < N ACCESS EASEMENT = o o �o m z D 0-) VARIABLE WIDTH R/W / > D m O �' (D.B. 874-738) — o a- 0-)o z J 0 r D �o / D ! -n m rC2 rA cn �A iv — Co C� O O� J u� CDU O EXISTING B UN A Y IN _ — VARIABLE WIDTH R/W OHU —� C• 0 30 •• •• Graphic Scale: n I D 7JJ O n C C cj� m G :J J 00 77NCD�CJ� z O N m CmJ�7J � �� W J�DC3i <nN�cfl�n D m 0 O D -0 F- � O zi DDD-u SHIMP � � O ENGINEERING O LAND PLANNING - PROJECT MANAGEMENT Z 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM o u . Sxnv� a Lic.4 183 Z � 2�2� w� �o ��SSIONAL ��G MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. 19.057 `n BOUNDARY LINE uo ADJUSTMENT EXHIBIT C3 c / T OHU 0V OHU OHU 0 OH / oy G O,y G / 0 oN� °N0 T. M 4 5- -112 A tiG /°Now MALLOY PROPERTIES MALLOY COMPANIE / o DH 4863 PC 4 c� ZONED: HC s c / EX. 9,120 SF BUILDING TO REMAIN AS VEHICLE SALES & STORAGE 11.7' ❑13❑ l ❑o❑ T.M 45-112B1 18.0' /A(:�-) MALLOY PROPERTIES III C/O MALLOY COMPANIES LLC9 00, UTCD R7-8 W/ D B 486 3 P C 471 R7-8a PLACARD ZONED: HC 1 OUTDOOR 19 CUSTOMER PARKING SPACESSALES/STORAGE 24.0INCLUDES 1 HC SPACE CURRENT USE: VACANTDISPLAY PARKING SPACE W t 0 MANAGED SLOPES a 1 .0 OUTDOOR S LES/S ORAGE DISPLA PARK NG 20.0' ❑ 15.0' o ❑ a 1 .0El ° Qu I c� \ U 0 1 .0' O 0 3' 2 9.0 3 0 CG-2 ❑ O PAVED PARKING AREA 24.0' O < N ONCRETE CONVEYANCE CHANNELFT1 - � _ o z ® 0 TDOOR SALES STORA E/DIS LAY P RKING 0 D 6.0' 19.0, co 24.0' 18.0' � 18. 0'-2 4. 0' I co � F O 9.0' D° �I iCJ 19.0' h1 n 9.0' D uu Q0 17171 z OUTDOOR K 0 SALES/STORAGE/DISPLAY LT1 PARKING z 24.0' RAVEL DIAPHRAGM sF' 2' CURB CUTS IN (TYP) ❑s EACH PARKING ❑ ❑ 22.1- o 9.0' 13 ,p P A_C E 6.0' �s z z U OHU OHU OHU 7L-- OHU OHU OHU OHU OHU OHU OHU OHU QHU OHU OHU I HU OHU OHU m 2'x25' LOADING SPA N I � T.M 45-68C1 MALLOY PROPERTIES III C/0 MALLOY COMPANIES LLC DB 4863 PG 461 ❑o ° ZONED: HC CURRENT USE: COMMERCIAL ON R E CONVEYANCE _ CHA N L a — cn— — c o OHU OHU OHU OHU 0 OH U HU OHU OFoi �F�U OHU OHU 0 OHU . 0 U— oy G • • 20 40 •• GraphicScale:• 1 OHU U OHU OHU OHU OHU OHU, , OpjU 0ldU HU OHu . OHU OHU°- SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM O� t • r? o'�., u . SHEYT a Lic. 4 21183 �O ��`sSIONAL VI MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. 19.057 cn U.S. ROUTE 29 SITE PLAN 0-) 24' JOINT SEMINOLE TRAIL oyG O : P ACCESS EASEMENT cj N UoVARIABLE WIDTH R/W O (D.B. 874-738) o M (--0J LO C� ` I K m C4 p D � / yG cfl O U.S. ROUTE 29 �� SEMINOLE TRAIL • • 20 40 •• Graphic Scale: • SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM o u . SHEYT a Lic.4 183 Z � 2�2� w� �o ��`sSIONAL ��G MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. GRADING PLAN 19.057 ir-lEDUUINU VARIABLE WIDTH R/WC5_ �� \ �o / I 0 O ' 502- °tiG z c / 0 OH / OHU OHU OHU OHU o B �s B I 0 < \ 0 � � � \ o Cb Oj / \ y � G- ---- -- --- / U � �✓c/ Z\ — o ON NP� / N�// B BB, B, v 0 T. M 45 112A \ ONU tiG/IALEY PRBERTIES �` ---- -------- 20 0 20 40 60 ONU - %498 MAEEOIY'COMPA/NI �,�`B`l.' ,� — � — B — � ��s �B B � / / S � \ \ \ Graphic Scale: 1„_ —20, 4g6JD/G� 4 o B /I / x s / cZONED: 6C / // s �s \� /\j — I -0\ \ I 494- /_--------B I I ,IEX. 9,120 SF �� B B I I I BUILDING TO p r7I \ \ I v I I I REMAIN AS B��B B A \ I VEHICLE SALES & �' n� B B x I I I I I STORAGE II II I I ----- I I FIFE 468.50 vf -r7 �� I 490 I II 488- I 1 \486, T. M 45- t1B1_ _ _ - MALLOY PROPERTIES III C/O �� ! \ B \\ \B MALEY COMPANIES EEC B / DB 4863 PC 471 ZONED: HC B I I 0w CURREINT- 4-JSEeVA-C-ANT o \ I N 00 v \ I I \ MANAGED SLOPE01 O N -__-- - -_ -- 480 I -o - � FT] 4 76 - O D -- - — — � Fr] --- - - D ---- �c 70 �Drqz ,——468--------------- -----El _ z --- 466—— — — — — —— \ \ % X 68 _ _ — — i o ;Z o \ 12 oo II ��_ 0, (ram n�+ < \ CocnuC \ � II fD< � "V oil �I \ Co �o< 0 C \ \ �< N< ?} t �< \ J < II \ \ \ \ II \ \ — \\S S S S S S S 12 CoONO LO S S S S S S S S Swo Z n S \ _ G � / III I Tl \ ^ w _ "_ I I \ V/J V / CD _+ IH OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU \ — — OHU HU OHU HU OHU — OHU U ^� HU OHL� OHU OHU U OHU OHU OHU OH HU15" CONOHU OH � 0�0 U� pkilgF}lY° — — OH _' — 464- _ \ — — �C� OHU�— HU O U �e OH 0 OHU, , OFiU , —_ O — \ W OkdlS HU Ouu . OHIJ — it < tiG _ 00 < _ % �I N ia-)O ll;u CO B c� B — U.S. ROUTE 2`9 X �, B cn B i 24 JOINT SEMINOLE TRAIL / D 0 (_0�� ACCESS EASEMENT VARIABLE WIDTH R W �/ D m o� M — o /' (D.B. 874-738) 0 < / o m LO r D // LO C� // // ° o < Ci O D —I m C I n 0o B I I 0 -7—w _w \ — w FT . 1 —7 II < z II CIO I I� ❑ I / 1D1-3 ❑ PE A4 5" N I T. M 45 68C1 co MALLOY PROPERTIES III C/O MALLOY COMPANIES EEC I " DB 4863 PC 461 ZONED: H C I I I CURRENT USE: COMMERCIAL I o I \ A3 �1E� � I IIIIIIIII�II P s 66 I I \ p p \ A2 13 \ DI- PF q „ PJ I 10 DI 7 T In` RAVEL DIAPHRAGM 68 (TYP) / SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM o� t• � o . SHEYT a LiC. 4 Z21183 � 2� w� �o IONAL MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. UTILITY PLAN 19.057 C6 LANDSCAPE SCHEDULE Plant Min. Total Symbol Planting Type . Botanical Name Common Name Cal./Height Quantity Canopy Canopy SF A Large Shade Tree Ulmus americans American Elm (Princeton) 3.5" Cal. 7 397 2779 a P 0 Large Shade Tree Quercus palustris Pin Oak 2.5" Cal. 8 370 2960 S Large Shade Tree g Zelkova serrata 'Green Green Vase Zelkova 2.5 Cal. 12 350 4200 Vase' B Medium Deciduous Tree Carpinus betulus European Hornbeam 2.5" Cal. 4 177 708 G�j0 Evergreen Tree Cryptomeria japonica 'Yoshino' Cryptomeria 4'-5' Ht. 4 123 492 Yoshino U Broadleaf Evergreen Magnolia virginiana Sweetbay Magnolia 6' Ht. 3 113 339 R � Ornamental Tree Cer'O rhomamis 'Oklahoma' Oklahoma Redbud 6-7' Ht. 5 124 620 P Deciduous Shrub Aesculus parviflora Bottlebrush Buckeye 30-36" 20 36 720 G Evergreen Shrub Ilex glabra 'Densa' Densa Inkberry Holly 30-36" 38 23 874 PiM Evergreen Shrub Rhododendron 'PJM Elite' Rhododendron 30-36" 40 13 520 TOTAL CANOP 14212 SF SEE PLANS FOR EXACT LAYOUT. SPACE PLANTS AS SPECIFIED IN PLANT LIST OR AS SHOWN. ADJUST SPACING AS NECESSARY OR AS DIRECTED BY LANDSCAPE ARCHITECT. 64 6� MULCH 2" DEEP IMMEDIATELY a � AFTER PLANTING AND WATER o D THOROUGHLY. 4 PLANTING PIT. PREPARED SOIL SET SHRUB PLUMB. TOP OF ROOTBALL SHALL NOT BE MORE THAN 1" ABOVE FINISHED GRADE REMOVE BURLAP FROM TOP 1/3 OF ROOTBALL 3" TALL WATERING BERM FINISHED GRADE 112 BALL ' 8 DIA. MIN. w SOIL SURFACE ROUGHENED ry TO BIND NEW SOIL j SHRUB PLANTING DETAIL C7 Not To Scale SET TRUNK PLUMB. SEE PLANS FOR EXACT LAYOUT AND SPACING. ARBOR TIES, OR 1-112" SQ. OAK STf SET 180 DEGREE ly►.a�y:�aze�:�au�a APPLY 2" OF WOO AND WATER THOF 4" COMPACTED E� WATERING BERM EXISTING GRADE PLANTING PIT. SEE REQUIREMENTS, F PLANTING SOIL AN REMOVE BURLAP TOP 1/3 OF ROOT UNDISTURBED SO 2 TREE PLANTING DETAL C7 Not To Scale 0 LO 009-- x T.M 457112A,' AALLOY PR-OPERTIES' MALLO/Y-COMPA/'NI 4863 A/ 4 1 v ZONED: I6C � I ��J I I I I I I 1-2B1 TIES III C/o \NIES LLC G 471 I HC -V7CCAN T \I ;ED SL —S —S F U.S. ROUTE 29 i 24 JOINT SEMINOLE TRAIL / / ACCESS EASEMENT ( SOUTHBOUND LANE) � (D.B. 874-738) VARIABLE WIDTH R/W LANDSCAPE REQUIRED: SITE REQUIREMENT (32.7.9.8): 10% CANOPY REQUIRED. SITE AREA 92708.5 x 10% = 9,271 SF CANOPY REQUIRED: 9,271 SF CANOPY PROVIDED: 14,212 SF STREET TREES (32.7.9.5): LARGE SHADE TREES (3.5" CAL.) 35' O.C. PARALLEL TO ROAD REQUIRED: ROUTE 29 — 247 LF/35 = 7 TREES PROVIDED: 7 LARGE SHADE TREES & 5 ORNAMENTAL TREES INTERSPERED ALONG THIS FRONTAGE INTERIOR/PARKING LANDSCAPE (32.7.9.6): 5% OF PARKING PAVED AREA. 37803 SF x 5% = 1,890 SF 30 0 30 60 90 LANDSCAPE REQUIRED: 1,890 SF LANDSCAPE PROVIDED: 5,650 SF Graphic Scale: 1"=30' LARGE SHADE TREES (2.5" CAL.) 126 PARKING SPACES (126/10 = 13) REQUIRED: 13 LARGE SHADE TREES PROVIDED: 20 LARGE SHADE TREES SCREENING SHRUBS — AS NECESSARY TO MINIMIZE APPEARANCE OF PARKING NOTES: 1. Contractor to apply mulch bedding around all proposed trees and shrubs. All other landscaped areas shall be sodded. 2. All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. 3. All landscaping and screening shall be maintained in a healthy condition by the current owner or property owners' association and replaced when necessary. Replacement material shall comply with the approved landscape plan. 4. Visibility of all mechanical equipment from the entrance corridor shall be eliminated. I IIII I'I'I I I °III IIII IIL,I IIII IIII II n III D � IIII II � II IIII I I` IIII o 00 —I I 1p IIII CD I IIII co_cn II IIII �G 00 Ij IIII F7 00 — � (I IIII Z O ul rr . % IIII C m N J �r III now�a�0M(j, dI III = r F- � Id III nC0 11 III D �00 I III I°� III Z rDF-7uSHIMP 11 III — >--�>v ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 1992 3.38 Source: Va. DSWC Plate 3.38-2 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM O� A Gf.P v . SHIMP Y Lic. &24 183�2� 4� MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. LANDSCAPE PLAN 19.057 III - 401 C7 LIGHTING NOTES: 1. Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one—half foot—candle. 2. All new pole mounted luminaires shall be mounted at a max height 20' above the finished grade with the total height including the concrete base. 3. No fixture to be installed shall be aimed or positioned in an irregular manner. All lighting shall be directed straight down. 4. All new fixtures to have Dark Bronze finish. Schedule Symbol Label Quantity Manufacturer Catalog Number Description Lamp Number Filename Lumens Per Light Loss Wattage Lamps Lamp Factor ❑ 8 Lithonia Lighting CSX1 LED 60C 1000 40K T41M CONTOUR SERIES LED AREA LUMINAIRE WITH LED 1 CSX1_LED_60C_1000_40K_T4M.ies Absolute 1 627 B 60 4000K LEDS OPERATED AT 1000mA AND PRECISION MOLDED ACRYLIC TYPE IV LENS ❑ 3 Lithonia Lighting CSX1 LED 60C 1000 40K T31M CONTOUR SERIES LED AREA LUMINAIRE WITH LED 1 CSX1_LED_60C_1000_40K_T3M.ies 22277 1 209 D 60 4000K LEDS OPERATED AT 1000mA AND PRECISION MOLDED ACRYLIC TYPE III LENS STATISTICS: Average = 5.7 fc Maximum = 19.8 fc Minimum = 0.0 fc Max/Min = N/A Average/Min = N/A k-6, O O � O k k Q k CT 0 O k k ') Cry CP k k O S k k Uj k % k k O .� k '� k O Ar O 0 O o > k k A' •� •� •C 'Cr O O k .O k ' j Q O Q 'CT •� 'CT k .� i i k O O k W k I I C� Q % 0 k Q k k Q k k •� k O o o k k T k % k k lJ k Q,(, Cr k k (9 k 0 Q Q O / k C9 Q k k Q k � k J k o •� k k % '� k k Q k O O oW k k ❑ f❑ k .0 k o •� •� D .o k .Q k ' oft k •� k / k k 1p O % k Q Q k k I o� •(� k .o .w k 'Ui k 'Q k O k 0 i .o k CID J k '-, k .o k O o lJ k k O k l� CID Q k k o i CP k k O k k C9 CID •� k •� k % k 0 0 CID k % O k c9 .0 % Q C9 ID k k t9 j oQsi •� Al .O Cr k 'j k • k lJ 0. FOOTCANDLE CONTOUR w k 0A k Q k �, k CP CP 0 k Cr k w 0LQ 0 O k CT k CID Q k � k Q CID CIP C� o k CA t3k '--, �. CID CT k 'Q k Q Q dQ Q k Q k t C9 ' Q k k Cr k 0 J k ts% k k i -A k CP k 0 CID Q Q IK catalo •� J k k > > i k k '0 Q Q J •� k o k •� CSX1 LED I Number k � 0\ k o k o Q _a � k •,, k o C 5� � k O k 0A ,� � k k � CIDk k LED Area Luminalre Notes Al .o k Q k O k -; .Q k Q k S7 J Q Q I Q k .Q � i k O k k Lo c9 •Cr k I ,CID .-, k k C9 ,p Q k .Q k Q 0 o k k i k '(r k ` Type k C7� k k Q Q k k O I. t .S k J I '37 k 'C9 k ., k '., FuIENaY J � k k O k (.' M 'lJ� k • J k Q J ' J k •� NIGHTTIME e n a k 'Cry k CT Q9 '-, k k Q -•� k k % l j A, O Cr -� k U, ' k o ' o k Qfl k . o `J k k '�ca+ Capable Luminaire 0% k % -, k CID Q9 O k CT P k k o k .0 k > CP � k 0 00 k cA k T3 This item is an A+ capable luminaire, which has been 0 k x k O k k -� c9 O designed and tested to provide consistent color k o k S -' k o k o Cry � � Specifications 9 k Cr •0 k� k o k k '0 k k 0.7 ft2 appearance and system -level interoperability. k •� k CP k 'j k C� G J J k k % EPA: H � k ` k o , k O (P k 0 (0.07,2) All configurations of this luminaire meet the Acuity k Q FE k c9 > > k S k tJ k Q3` 6' 23-1/2„ 9 Y Q ; 0 k Q > > k k > Q9 k Ck� Length: L Brands' specification for chromatic consistency .Q k 'Cry CSC Q k O J k k CID (59.7cm) W k Q3` k k k 0 ,� Qr� O � -� k �' k 1 • This luminaire is A+ Certified when ordered with DTL® A, 'Q k j k k c9 vj '� k k k Width: 18 1/2 controls marked b a haded background. DTL DLL Q9 Q o J 'Q k 'Q k (46.9(m) �„� Y k. g Al 1_3c?` j j j o k -S k k j 0 k > k k O O 5 7/$„ equipped luminaires meet the A+ specification for O c9 k 6' k k c3` luminaire to hotocontrol intern erabilit 1 •C k k J j .0 Height: p p Y k C1� I I k i Q k 63 (14.9(m) W LP k n k _ tJ k > > > CP k Q k (P 6> k 6' k This luminaire is art of an A+ Certified solution for k •� k � > o k � � k Weight 371bs p k I C� k o is ® XlPointTM �J k ❑Q k C� J Cr k k Cl> > % 37 k k Q (max): (16.8k91 ROAM 2 or XPoint Wireless control networks, I CS k > > k J7 Ct� k O w k , k tJ CT k 0 S providing out -of -the -box control compatibility with Lp k 0 k try O k k simple commissioning, when ordered with drivers and A, c9 1 Q k 0 k iJ .0 c9 > > >f( )) Q k 0 •� k k p g� W O O k J 6\ j O > j k k Q� 0 Q k 0 k W k k control options marked by a shaded background' CT > > J j k k �� CT % O _ k CID ' C10 To learn more about A+, c9 k k O k j j j j w k CP k n j .� k O 0\ visit www.acuit brands.com/a lus. k 0 k k Q - CS% J k k % CT) J .� k k .� Y p Cq 6' k 'do k k > ; � k Q k �\ L l`� Cp k 1. See ordering tree for details. J k CID ' k ' C� ' U .Q Al k k -� k .S k k t9 k J 'CO O k VVV��� k k c,,� 0 j .Q 2. A+ Certified Solutions for ROAM require the order Al CIDk k 6� k , k j j k k o k of one ROAM node per luminaire. Sold Separately: k k .0 co > k > , k Link to Roam; Link to DTL DLL k � lJ o J Cry k Q k CP > k t9 > k O k �1 A+Capable options indicated (5N k (� k O k k O k t� J c9 by this color background. �J k Q PC%k CP k k 0 CID do % ` j k Cry CID Q k Cry k Q,; k cA k o k LC Ic9 k k k O • • - - EXAMPLE: CSX1 LED 60C 1000 40K T3M MVOLT SPA DDBXD S k k Q % k k .o k CID J Q k l� k O do J k (9 k O k 'yam k o I J 'Cr k 'Lp k Q },7 O ' O k c9 k ', O j �� k o k �0 -- t9 Cry k Q k > k O CSX7 LED 60C Q k QLIN Ok O 0 k k O Q9 k O Cr k Cry 0 O CID Qg k k j k O OLIN k 3� k O k j ', j k ^� k O O j k S k k CID CP > k k Q t9 k O CSX1 LED 60C 60 700 700 mA 40K 4000 K T2M Type II MVOLT' Shipped included Shipped installed DDBXD Dark bronze O k k k Q k � tg k k LEDs 1000 1000mA 50K 5000K T3M Type Ill 120' SPA Square pole PER NEMA twist -lock receptacle only (no controls) DBLXD Black Qr� k 6a k O k k cs` O k (1 A) mounting k Cp Q CP k O k S k -� � T4M Type IV 208 9 DCR Dimmable and controllable via ROAM (no DNAXD Natural O k o k 6� CA --� k Q` k O c9 CP k O RPA Round pole controls) s aluminum k c9 O k CP c9 /��- k 57 k k CjS3T T5M TypeV 240' p e tP k O 0 k O k 0 � ) t9 CT C9 CT k Q mounting DMG 0-10Vdimmingdriver(nocontrols) DWHXD White O k O k > ` CID c9 c9 V k � k > c9 c9 k TFTM Forward 277' 2 k � k -- A'� k k O throw WBA Wall bracket H5 House side shield DDBTXD Textured O O o o k 1 ` J0 —� 0 61 k CP k k 347 Shipped Separately 2 SF Single fuse (120, 277, 347V)' dark bronze Cry k o Cis k CT k k Cn k k Ta ® Q 480 SPUMBA Square pole DF Double fuse (208, 240, 480V)' DBLBXD Textured k 0 � k k W as black k O > k 6> k k O O O universal DS Dual switching O k k O > k k k '(� k mounting BL30 Bi-level switched dimming, nominal 30°k 910 DNATXD Textured k O k Qfl k O '( adaptor' 910 natural k lJ k k O BL50 Bi-level switched dimming, nominal 50% aluminum O o O CP k k 0 k W k RPUMBA Round pole 2 k k j "� k c9 > k CA k o o Q universal Shipped separately DWHGXD Textured O O k w k —� k O k k O k mounting VG Vandalguard white k k •w 0 > j Q k O k > CP k k Q k adaptor' BS Bird-deterrantspikes O CA k 3T k O 0 k KMA8 DDBXD U Mastarm k k J k 'O k J k 'O k •� o mounting O O k k > > k �J k O O k � bracketadaptor k k O k k > > k t9 k o (specifyfinish)° O O w x CA k -o > > k k O k > O 0 O k k®�pp—�� — --- k Q k O-----------'� 0 Q O k (Q k c9 k Q 0 O O k O o o rp Q -------0 - --0-- CT -- CID --- 0\ .Q k O o k Q o®-------- O k o i k Q Q Q Qr O 'Cr Qrk O k 'CJ� k O k > ., k � k 'P k 0 Q O ' Q ' RIGHT O F WAY LINE Q k Q k O w k O Ok % k fA L/THON/A One Lithonia Way •Conyers, Georgia 30012 •Phone: 800.279.8041 www.lithonia.com k ' j k Cry k o O k o L/GHT/NG 02012-2017 Acuity Brands Lighting, Inc. All rights reserved. o k Q O k .0 O 0 o r k k o O k k .� 0 0 0 0 ' k > k �.7 k o O 0 k 3 k O ' k % k % Ar J k k o O Qk V3 k .� k k Q•� O l`� Q .' k O o 0 k k Q, k Q Q o k > 0' 0 x • • 20 40 •• Graphic Scale: • SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM 0� Y Grp G� O v . SHIMP a Lic. 4 1 L2�83 2v w� SSIONAL MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. LIGHTING PLAN 19.057 go STORM PPE PROF LE Al -A4 C9 HORZ: 1 "=20' VERT: 1 "=10' 5 PAVEMENT DETA L C9 NOT TO SCALE A k 2 4B75' 5' RESERIED__ 2 4.25 4.25 1 PARKING2C _ I , 1 18 4" B 3,875 �A 3.S15 1 I.! .75 2.5 a12 117-8 NO PARKING LEGEND - GREEN (RETROREFL), WRITE SYMBOL ON BLUE (RETROREFL) BACKGROUND -WHITE (RETROREFL) "Reduce spacing 50%. "*See page 6-31. "**See page 6-2 for arrow design. 475 470 465 460 5$55 2" SM-9.5A SUPERPAVE 6" VDOT #21 A BASE STONE COMPACTED SUBGRADE VA �XCCESSN IBLE {{IIIII'' I _77�1 r_ A ...R7-& H!-10 VMACCESSABLE n A I B I C D E F G N J K I. i? F s75 aaR IS i.4U 5 11) 1.01 ales .9 18 9 375 .AaB 225 20 1 US It 2496 5784 1.5 PARKING APPLICAIION DIRECTIONAL APPLCAT M CULDR& LEGEND -GREEN (REIR(1REELMNEIDRRLACK CDLURS LEGEND-WHITE(RETRCREFLECTIVE) R.ACKGHOUND-WHILE (RETRMEFiEII;ME RMMGRMM-RLRE (REfRDREFLECTNE} CG-6 NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3. COMBINATION CURB & GUTTER HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB)SHALL BE PAID FOR AS RADIAL COMBINATION CURB & GUTTER. 4. FOR USE WITH STABILIZED OPEN -GRADED DRAINAGE LAYER, THE BOTTOM OF THE CURB AND GUTTER SHALL BE CONSTRUCTED PARALLEL TO THE SLOPE OF SUBBASE COURSES AND TO THE DEPTH OF THE PAVEMENT. 5. ALLOWABLE CRITERIA FOR THE USE OF CG-6 IS BASED ON ROADWAY CLASSIFICATION AND DESIGN SPEED AS SHOWN IN APPENDIX A 2" R OF THE VDOT ROAD DESIGN MANUAL. 6„ D D D D IN V T. D D D D , D • s s D D D D D D D IN IN D D IN D D - - THE BOTTOM OF THE CURB AND GUTTER MAY BE CONSTRUCTED t PARALLEL TO THE SLOPE OF 6" 2'-0" SUBBASE COURSES PROVIDED A MINIMUM DEPTH OF 7" IS MAINTAINED. THIS AREA MAY BE CONCRETE AT THE OPTION OF THE CONTRACTOR SPECIFICATION REFERENCE COMBINATION 6" CURB & GUTTER 105 REV. 9/O6 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 201.03 LD-204 Stormwater Inlet Computations Sag Inlets Only iu -0 a) �_ M _ Z Q o m Q Q U O X c E o c a) Q U c�i H a) > _ a in a � C0 0- (D 1 2 3 4 5 6 8 9 10 11 12 13 14 15 21 22 23 24 (ft) (ac) (in/hr) (cfs) (Cfs) (Cfs) ( ft/ ft) ( ft/ ft) ( ft/ ft) (ft) (ft) (ft) A4 DI-3C 8 0.23 0.82 0.19 6.5 1.23 - 1.230 0.013 0.018 0.028 0.15 0.50 0.29 5.88 0.82 0.19 4.0 0.76 - 0.757 0.013 0.12 0.50 0.24 4.26 A2 DI-3C 8 0.59 0.75 0.45 6.5 2.90 - 2.901 0.013 0.027 0.018 0.080 0.23 0.50 0.46 5.77 0.75 0.45 4.0 1.79 - 1.785 0.013 0.17 0.50 0.33 2.28 Al DI-7 0.58 0.87 0.50 6.5 3.28 - 3.278 0.013 0.024 0.014 0.15 0.50 0.31 11.00 0.87 0.50 4.0 2.02 - 2.017 0.013 0.13 0.50 0.26 9.20 IS-1 '9 ° SHAPE TO ELEVATION j L MID -POINT OF LARGEST PIPE. • j SHAPE TO i. CONTOUR . , OF PIPE I / • ji A °A A" °A SLOPE TO DRAIN TO INVERT \� OF OUTLET PIPE SECTION A -A ° TRANSITION BETWEEN ° PIPE DIAMETERS WHEN METHOD OF TREATMENT IN DROP INLETS DFFERENT SIZES OF PIPES ARE ENCOUNTERED. NOTES: SHAPING OF MANHOLE AND INLET INVERTS IN ACCORDANCE WITH \ THIS DRAWING IS TO APPLY TO THOSE STRUCTURES SPECIFIED ON PLANS OR WHERE INVERT OIF PIPE IS ABOVE INVERT OF SLOPE TO DRAIN TO INVERT OF STRUCTURE. j OUTLET PIPE MANHOLE OR DROP INLET IS TO BE FORMED AND CONSTRUCTED / ° IN ACCORDANCE WITH APPLICABLE STANDARD OR SPECIAL DRAWING. THE INVERT SHAPING AS DETAILED HEREON IS TO CONSIST OF A v PORTLAND CEMENT CONCRETE MIX CONFORMING TO CLASS A3 OR CLASS C1,EXCEPT THAT 25X OF COARSE AGGREGATE MAY BE / / n UP TO 4" IN DIAMETER AND CONSIST OF STONE, BROKEN BRICK, v v BROKEN CONCRETE OR BROKEN CONCRETE BLOCK. THE SURFACE �'.• ° SHALL BE LEFT SMOOTH BY MEANS OF HAND TROWELLING. NONE A OF THE COARSE AGGREGATE SHALL REMAIN EXPOSED. ° Q DETAILS OF INVERT SHAPING AS SHOWN HEREON ARE FOR EXAMPLE - ' PURPOSES ONLY. EACH MANHOLE OR DROP INLET IS TO BE SHAPED - INDIVIDUALLY TO BEST FIT THE PARTICULAR INLET AND OUTLET CONFIGURATION AND FLOW LINES. SECTION B-B PLAN METHOD OF TREATMENT IN MANHOLES �� STANDARD METHOD OF SHAPING SPECIFICATION REFERENCE ROAD AND BRIDGE STANDARDS M AN H 0 L E & INLET INVERTS SHEET 1 OF 1 REVISION DATE VIRGINIA DEPARTMENT OF TRANSPORTATION 302 106.08 CG-2 NOTES- 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3. CURB HAVING A RADIUS OF 300 FEET. OR LESS (ALONG FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB, 4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (15" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE THE DEPTH IS TO BE 18" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE N DEPTH. 4 2" R 5 CG-2 IS TO BEFOR USEDC ON ARgADWAYS MEETING THE REQUIREAPPENDIX �ESIGN A OF THE VDOT ROSAD MANUAL. 6" d ' .A •'d SURFACE SEE NOTE 4 BASE .'d - SUBBASE 4 f 2' RADIUS 6 G I "d d - d SURFACE MIN MIN - 18" d :•a a MAX. BASE d• SUBBASE 12" y ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED SPECIFICATION REFERENCE STANDARD 6" CURB 105 502 VIRGINIA DEPARTMENT of TRANSPORTATION REV. 9/06 201.01 LD-229 Storm Drain Design Computations Mallov Furniture Store From Point To Point Catch A (ac) Runoff Coef Inc AC Accum AC Tot Tc (min) Tot Int (10yr) (in/hr) Tot Flow (10yr)(cfs) Up Inv El Dn Inv El Pipe Len (ft) Inv S % Pipe Dim (in) Pipe Cap (cfs) Velocity (ft/s) Flow time Inc (min) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 15 16 17 A4 A3 0.23 0.23 0.05 0.05 5.00 7.10 0.38 463.65 462.68 42.25 2.3% 15 11 4.1 0.17 A3 A2 0.38 462.48 461.81 29.05 2.3% 15 11 4.1 0.12 A2 Al 0.59 0.59 0.35 0.41 5.00 7.10 2.88 461.61 460.60 44.81 2.3% 15 10 7.2 0.10 PB 1 NO PROJECTION OF PIPE ABOVE GROUND LINE TOP OF FILL --- TOP OF FILL TOP OF FILL - GROUND LINE = GROUND LINE = GROUND LINE x - r r -1 =1 =1 rrrrrrr rrrrrrr III=1 =1 I- _ FI Im 1 r rrrrrr rrrrrr rrrr - _ III=III-1 _ rrrrrrrr rrrrrrr _ -1 =1 =1 rrrrrr rrrrr III=1 =1 N -'-III I -I =III rrrr rrr-III- rrr rr rr d rr - EARTH `' 111 Frrrr rrrr-III N-I rrr rr + III rr d rr L ROCK OR `'1 I rrrr l%rrr I-- N l l-I rr rr + III rrr d r = EARTH o N 1 1 o N -1 SOILUNYIELDING I I. o N 1I I= 0 �I = 11 o �I 0 BEDDING - � -I MIN. I-III=III-III MATERIAL MIN. 1/10 D - - - - 1 ' I =I 1=III=III=III I 4 MIN. 1/10 D X D X BEDDING 1/10 D X D X BEDDING MATERIAL � MATERIAL X D X PER 1' OF H MIN. 8", MAX. 24" FOUNDATION SOFT, YIELDING, OR NORMAL EARTH FOUNDATION ROCK FOUNDATION OTHERWISE UNSUITABLE MATERIAL PIPE PROJECTION ABOVE GROUND LINE MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x D MIN. 1.5 x D TOP OF FILL TOP OF FILL TOP OF FILL ar - .rrrrrrr rrrrrrr = - rrrrrrrrrrrrrrr rrrrrrrrrrrrrrr = rrrrrr rrrrrrr = ;rrrrrrrr rrrrrr - - - - _ rr + •• •rr GROUND d = rrrrr rrrrr : - - - 'rrrr rrr - • • rr + GROUND - [14rrr - - rrrrrrrrrrrrrr rrrrrrrrrrrrr rrrrrrrr rrrrrrrrrr rrrrrrrrrr rrrrrrrrrr - - - rr. LINE w r d rr • LINE o + _rrrrrrrrrr d rrrrrrrrrr _ GROUND _-LINE - Hill 11- III III=1=1=1 III EARTH 11 OR MIN. 1/10 D _-ROCK --=UNYIELDING 4=4 =_ _- - - - - EMIN. MIN. 1/10 D 9 BEDDING EARTH 1/10 D X D X BEDDING MATERIAL -- /z" PER - - - SOIL 1" OFX D X ..H MIN.8", BEDDING MATERIAL MAX. 24'' MATERIAL FOUNDATION SOFT, YIELDING, OR NORMAL EARTH FOUNDATION ROCK FOUNDATION OTHERWISE UNSUITABLE MATERIAL ®BEDDING MATERIAL IN ACCORDANCE WITH EMBANKMENT SECTION 302 OF THE ROAD AND BRIDGE ® NOTES: SPECIFICATIONS. FOR GENERAL NOTES ON PIPE BEDDING, CLASS I BACKFILL MATERIAL IN ACCORDANCE SEE INSTALLATION OF PIPE CULVERTS WITH SECTION 302 OF THE ROAD AND BRIDGE AND STORM SEWERS GENERAL NOTES SPECIFICATIONS. ON SHEET 107.00. REGULAR BACKFILL MATERIAL IN ACCORDANCE rrrrr FOR PLASTIC PIPE CLASS I BACKFILL MATERIAL WITH SECTION 302 OF THE ROAD AND BRIDGE CRUSHED GLASS CONFORMING TO THE SPECIFICATIONS. IN ACCORDANCE WITH SECTION 302 OF THE ROAD SIZE REQUIREMENTS FOR CRUSHER RUN AND BRIDGE SPECIFICATIONS. AGGREGATE SIZE 25 AND 26 MAY BE USED IN PLACE OF CLASS I BACKFILL. FOR ALL OTHER PIPE REGULAR BACKFILL MATERIAL rrrrr IN ACCORDANCE WITH SECTION 302 OF THE ROAD AND BRIDGE SPECIFICATIONS. XVDOT INSTALL. OF PIPE CULVERTS AND STORM SEWERS SPECIFICATION REFERENCE ROAD AND BRIDGE STANDARDS CIRC. PIPE BEDDING AND BACKFILL - METHOD ,A,, 302 SHEET 1 OF 4 REVISION DATE 07/12 VIRGINIA DEPARTMENT OF TRANSPORTATION 303 107.01 DI-3A, 38, 3C FYIDAKM1 KI IOIHT , I -A 18��� N 4'; FOR DETAILS OF INLET FRAME & COVER SEE STANDARD IC-2. -BARS C BARS F BACK OF SIDEWALK II L `BAR F I- BAR A II BARS D FACE OF CURB CONTROL JOINT GUTTER CRACK CONTROL JOINT PLAN -VARIABLE - MAX. 20' F--B 3'-0" EXPANSION KEYED JOINT Y CONST. JOINT BARS D s=// �APPROACH GUTTER BAR G 2 / WARPED w 0 00 GUTTER BAR C I SUBBASE B 2„ HARDWARE CLOTH z + BARS F I WEEP HOLE. o O N O p SEE NOTE 8 r l M L I x w STEPS.'SE NOTE 5 8" R.. I8„ 6' MIN. SECTION A -A 10' MAX. KEYED CONST. JOINT 2'-10" 2" WARPED 2„ GUTTER x APPROACH BARS A GUTTER I o0 I- I - - - - - - - - - - - - - - - - - - - - tS G I BARS F BARS E B N do *3" DIAMETER BARS E WEEP HOLE BARS B FRONT ELEVATION BARS F $" $" $" - - - - - - (GUTTER REMOVED) 11/e" 3' - 0" 8 �A 8 5X1/q" BENT PLATE \ SECTION B-B cq " R TYPE A NOSE DETAIL SHALL BE USED WITH CG-3 & CG-7 STANDARDS. I/a L2%2"X21/2"XI/4" TYPE B NOSE DETAIL SHALL BE USED WITH CG-2 & CG-6 STANDARDS. GALVANIZED TYPE A TYPE B I/2" X 4" STUD SHEAR CONNECTOR WELDED GALVANIZED PLATE FOR TYPE A TO BE BENT ON AN ANGLE OF 68'30' TO ANGLE IRON AT 2'C-C. CONNECTORS AND IS TO BE ANCHORED WITH I/Z" X 4" STUD SHEAR NOSE DETAILS WELDED TO BENT PLATE AT 2'C-C. 2" APPR. PAVEMENT DI-3B L DI-3C L WARPED PAVEMENT LAI R� = FLOW FLOW I FLOW 1 DETAIL WHEN USED FOR USE ON GRADES ADJACENT TO CURB FOR USE IN SAGS WITHOUT GUTTER BOTH SIDES TO BE SYMMETRICAL XV DOT STANDARD CURB DROP INLET SPECIFICATION ROAD AND BRIDGE STANDARDS REFERENCE SHEET 1 OF 2 REVISION DATE 12" - 30" PIPE: MAXIMUM DEPTH (H) - 8' 233 104.09 08/10 VIRGINIA DEPARTMENT OF TRANSPORTATION 302 SHIM ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM SHIMP a Lic. .41183 CS� IONAL MAJOR SITE PLAN AMENDMENT MALLOY FORD ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.04.20 REVISION: 2020.06.22 FILE NO. 19.057 SITE DETAILS & PROFILES C9