Loading...
HomeMy WebLinkAboutSDP202000017 Correspondence 2020-07-01 (2)SHIMP ENGINEERING, P.C. Design FOCUsed Engineering February 18", 2020 2511 Avinity Drive Fixture Counts Apartment 101: 24 bathroom units > each w/ 3 fixtures (we, lav, shower/tub) = 72 12 kitchen units > each w/ 2 fixtures (sink, dishwasher) = 24 12 laundry units > each w/ 1 fixture (washer) = 12 Total Count: 108 Apartment 201: 18 bathroom units > each w/ 3 fixtures (we, lav, shower/tub) = 54 12 kitchen units > each w/ 2 fixtures (sink, dishwasher) = 24 12 laundry units > each w/ 1 fixture (washer) = 12 Total Count: 90 If you have any questions or concerns, please feel free to contact me at stephanic(a)shimp enmg eering corn or by phone at 434-227-5140. Regards, Stephanie Paul Site Designer. Shimp Engineering, P.C. 912 E. High St. Charlottesville, VA 22902 1434.227.51401 shimp-engmeering com 2511 Avinity Drive Water Pressure Calculation to Highest Apartment Fixture Pressure at Existing Fire Hydrant psi Pressure at Highest Fixture 1:1215psi(min. 20 req.) Head Loss due to Friction Hazen -Williams Equation Pd = (4.52*L*Q"85)/(C1.es*d4.87) C = 1140 (far Ductile Iron Pipe) Waterline Reach (starting from Ex. FHA) d (in) L (ft) Q (gpm) Pd (psig) To 12x8 TS&V 12 130 684 0.06 To New Onsite FHA 8 176 684 0.60 Totall 0.66 Head Loss due to Elevation Change Highest plumbing fixture elevation Fire hydrant elevation Head loss per foot Total head loss psi psi psi [Apsi ft ft psi (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) WATER DATA SHEET Date 06/2912020 Project Name 2511 Avinity drive Project Location Albemarle County, VA Consultants Shimp Engineering, P.C. Sources Design Population 24 multi -family units Hydraulic Capacity approx. 4800 gal/day Pipe Material Dz.P Pipe Diameter (Inches) Length (Feet) 4" 8 6" 81, 78.3 10" 12" Fire Hydrant Assemblies Valves: (11) Fittings (A) Gate 3 (B) Air Relief a (A)Cross 0 (B) Tee 3 (C) 900 Ell 0 (D) 45' Bend o (E) 22% Bend o (F) Reducer 1 (G) Blow -off Assemblies (Number) (Number) (Number) (Number) (Number) (Number) (Number) (Number) (Number) 1 (Number) (12) Minimum pressure at critical water meter 29.4 Authority Provide: Booster Station Storage Reservoir (20 psi required) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) SEWER DATA SHEET Project Name 2511 Avinity drive Project Location Albemarle County, VA Consultants Shimp Engineering, P.C. Waste Treatment Facility Moores Creek Design Population 24 multi -family units Connections 2 buildings via 1 connection Industrial Waste no Pipe Material NfA Date 06/29/2020 (Number) (Number) Pipe Diameter (Inches) Length (Feet) 6" 0 8» 0 10" 0 12" 0 15" 0 18" 0 21" 0 24" 0 TOTAL FEET 0 Manholes: (A) Standard 0 (B) Drop 0 (A) Siphons & Pump Stations 0 (B) Force Main (Size -Length) 0 Authority Provide: Drainage Basin _ Sub Drainage Basin A-2 (Number) (Number) (Number) (Feet)