HomeMy WebLinkAboutWPO200500013 Plan - As-built 2020-07-27ALBEMARLE COUNTY, VIRGINIA PREPARED BY: e Pti1 01- �7 Nr TERRA Steven LDnve ENGINEERING �Lic. No. 001866 AND LAND SOLUTIONS z/a/40 CIVIL ENGINEERS PLANNERS LAND SURVEYORS 9,1D SUR"N 415 4th STREET, NE CHARLOTTESVILLE, VIRGINIA 22902 PH. 434-244-0600 FAX 434-975-0900 DATE. 02-12-20 GENERAL NOTES: PRO ECT DATA: GENERAL ROAD CONSTRUCTION 17. A VIDEO CAMERA INSPECTION IS REQUIRED FOR ALL STORM SEWERS AND CULVERTS THAT ARE DEEMED INACCESSIBLE TO VDOT OWNERIDEVELOPER: THE ROCKS LLC INSPECTIONS AND ARE TO BE ACCEPTED INTO VDOT'S MAINTENANCE PROGRAM IN ACCORDANCE WITH VDOT'S VIDEO CAMERA 1340 STONY POINT ROAD 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS, INSPECTIONS, BONDS AND OTHER APPROVAL 1. ROAD CONSTRUCTION THE ABBREVIATION VDOT MADE HEREAFTER REFERS TO THE VIRGINIA DEPARTMENT OF TRANSPORTATION. THE INPECTION PROCEDURE AND WITH A VDOT AND/OR COUNTY INPECTOR PRESENT. IN ADDITION, IF HIGH -DENSITY POLYETHYLENE (HDPE) CHARLOTTESVILLE, VA 22901 RELATED ITEMS IN ACCORDANCE WITH LOCAL AND STATE POLICY. TERM COUNTY REFERS TO THE COUNTY OF ALBEMARLE, VIRGINIA. PIPE IS TO BE USED, THE MANUFACTURER SHOULD HOLD A PRE -CONSTRUCTION MEETING FOR INSTALLATION TRAINING. THE PIPE MANUFACTURER SHOULD SPEND A MINIMUM OF TWO HOURS ON THE JOB SITE DURING THE INITIAL PIPE INSTALLATION. 2. THE CONTRACTOR SHALL VERIFY THE PROPOSED LAYOUT WITH ITS RELATIONSHIP TO THE EXISTING SITE SURVEY. THE CONTRACTOR 2. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING CONNECTION TO ANY SHALL ALSO VERIFY ALL DIMENSIONS, SITE CONDITIONS, AND MATERIAL SPECIFICATIONS AND SHALL NOTIFY THE OWNER AND ENGINEER EXISTING ROAD, A PERMIT FOR SAID CONSTRUCTION SHALL BE OBTAINED FROM VDOT. THIS PLAN AS DRAWN MAY NOT ACCURATELY 18 PROVIDE END SECTION OR HEADWALLS ON CULVERTS AS SPECIFIED. PLACE CULVERTS IN STREAMBED WHEN POSSIBLE. LENGTHS OF ANY ERRORS, OMISSIONS OR DISCREPANCIES BEFORE COMMENCING OR PROCEEDING WITH WORK. REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL SPECIFIED ON CULVERTS INCLUDE END SECTIONS. APPROVED 3. DEVIATIONS FROM OR CHANGES TO THESE PLANS ARE EXPECTED. SEE CORRESPONDENCE WITH COUNTY ENGINEER DATED 6/13/05 AND GOVERN. 19. CLEAR SIGHT LINES MUST BE PROVIDED AT ALL INTERSECTIONS. CONTRACTOR SHALL CLEAR AND GRADE AS NECESSARY TO PROVIDE by the Albemarle County WAIVER APPROVAL CONDITION. 3. CONSTRUCTION INSPECTION OF ALL PROPOSED ROADS WITHIN THE DEVELOPMENT WILL BE MADE BY THE COUNTY. THE CONTRACTOR THE REQUIRED SIGHT DISTANCES. MUST NOTIFY THE DEPARTMENT OF ENGINEERING (296-5861) 48 HOURS IN ADVANCE OF THE START OF CONSTRUCTION. Community Development Department 4. THIS PLAN DOES NOT GUARANTEE THE EXISTENCE OR NON-EXISTENCE OF UNDERGROUND UTILITIES. PRIOR TO ANY CONSTRUCTION OR 20. CONSTRUCTION DEBRIS SHALL BE CONTAINERIZED IN ACCORDANCE WITH THE VIRGINIA LITTER CONTROL ACT. NO LESS THAN ONE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE EXISTENCE AND LOCATION OF, OR THE NON-EXISTENCE OF, UNDERGROUND 4. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. ALL LITTER RECEPTACLE SHALL BE PROVIDED AT THE CONSTRUCTION SITE. Date O7/27/2020 UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING "MISS UTILITY" (1-800-552-7001). EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). 21. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM THE CONSTRUCTION LIMITS OF THE ROADWAY BEFORE PLACING EMBANKMENT. File WP0200500013 - Newcomb MOUDi81D Labe (Phase 1) 5. THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ANY EXISTING UTILITIES NOT OF RECORD OR NOT SHOWN ON THESE PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING, AT HIS EXPENSE, ANY EXISTING UTILITIES 5. EROSION AND SEDIMENT CONTROL MEASURES SUBMITTED ARE BASED ON TYPICAL ERODIBLE SOIL MATERIALS. AS CONSTRUCTION 22. OUTFALL DITCHES SHALL BE GRADED AS NECESSARY TO PROVIDE A MINIMUM SLOPE Of 1 % FROM OUTFALL AT CULVERT TO EXISTING DAMAGED DURING CONSTRUCTION. IF A UTILITY IS DAMAGED DURING CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY THE COMMENCES AND ROCK CONDITIONS ARE DETERMINED, FIELD REVISIONS WILL BE MUTUALLY DETERMINED BETWEEN CONTRACTOR AND GRADE IN EXISTING SWALES. ENGINEER. COUNTY STAFF. 23. ALL SPRINGS SHALL BE CAPPED AND PIPED TO THE NEAREST DRAINAGE DITCH OR DRAINAGE OUTFACE. THE PIPE SHALL BE MIN. 6" 6. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE 6. UPON COMPLETION OF FINE GRADING AND PREPARATION OF THE ROADBED SUBGRADE, THE CONTRACTOR SHALL HAVE CBR TESTS DIAMETER AND CONFORM TO VDOT STANDARDS SBA. OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY PERFORMED ON THE SUBGRADE SOIL. THREE (3) COPIES OF THE TEST RESULTS SHALL BE SUBMITTED TO THE COUNTY. IF A CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD SUBGRADE SOIL CBR OF 5 OR GREATER IS NOT OBTAINABLE, A REVISED PAVEMENT DESIGN SHALL BE MADE BY THE DESIGN 24. UNLESS OTHERWISE NOTED. THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL AND ALLEGED, IN CONNECTION WITH THE ENGINEER AND SUBMITTED WITH THE TEST RESULTS FOR APPROVAL. ALL PAVEMENT RETURN RADII AT INTERSECTIONS ARE 50 FEET. PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LABILITY ARISING FROM "THE SOLE NEGLIGENCE OF THE OWNER OR THE ALL PAVEMENT RETURN RADII AT CUL-DE-SACS ARE 35 FEET. ENGINEER". 7. MAXIMUM FILL AND CUT SLOPES IN SOIL SHALL BE 1 1/2:1. ROCK CUT SLOPES MAY BE STEEPENED TO 1/2:1 WITH STABLE ALL RIGHT-OF-WAY RETURN RADII AT INTERSECTIONS ANd CUL-DE-SACS ARE 35 FEET. PROJECTIONS ALLOWED. ALL CUL-DE-SAC PAVEMENT RADII ARE 45 FEET. 7. ANY DAMAGE TO EXISTING PHYSICAL FEATURES (WALKS, LIGHTS, TREES, SHRUBS, ETC.) SHALL BE THE RESPONSIBILITY OF THE ALL CUL-DE-SAC RIGHT-OF-WAY RADII ARE 55 FEET. CONTRACTOR. REPAIRS OR REPLACEMENT SHALL BE MADE AS NECESSARY AT NO COST TO THE OWNER. 8. GUARDRAIL MAY BE REQUIRED AT LOCATIONS NOT SHOWN WHEN, IN THE OPINION OF THE DIRECTOR OF ENGINEERING OR HIS DESIGNEE, IT IS DEEMED NECESSARY. 25. DEPTH OF DITCHES SHALL BE INCREASED AS REQUIRED IN A TRANSITION BEGINNING 20 FEET UPSTREAM OF CULVERT: THE DITCH SIDE 8. ALL TURF AREAS THAT ARE IMPACTED OR DISTURBED BY CONTRACTOR VEHICLES, EQUIPMENT OR ACTIVITY SHALL BE REPAIRED, SLOPES MAY BE INCREASED TO A MAXIMUM OF A 2:1 AT THE CULVERT. REGRADED, AND RESEEDED. 9. WHERE RURAL CROSS SECTION ARE INSTALLED, ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT STANDARD PEA. 26. ALL ROAD CULVERTS TO BE CONTECH HEL-COR ALUMINIZED STEEL TYPE 2 CORRUGATED STEEL PIPE (ACT-2 CSP). FLARED END 9. PARKING FOR THE CONTRACTOR'S VEHICLES SHALL BE COORDINATED THROUGH THE OWNER. THE OWNER IS NOT RESPONSIBLE FOR 10. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED TO STABILIZE A DRAINAGE CHANNEL WHEN, IN THE OPINION OF SECTIONS MAY BE ELIMINATED IN ROCK CONDITIONS SUBJECT TO REVIEW IN FIELD WITH COUNTY. THE LOSS OF ANY MATERIAL STORED AT THE SITE. PARKING OF EMPLOYEE VEHICLES WILL BE ACCOMMODATED AT THE SITE. VDOT, THE DIRECTOR OF ENGINEERING OR HIS DESIGNEE, IT IS DEEMED NECESSARY. 27. ALL DRIVEWAY CULVERTS TO BE 12" CMP, MINIMUM LENGTH 24', UNLESS NOTED OTHERWISE. 10. IN ACCORDANCE WITH SECTION 19.3-9.2 OF THE WATER PROTECTION ORDINANCE, EROSION AND SEDIMENT CONTROL PLANS FOR 11. A MINIMUM CLEAR ZONE OF TEN (10) FEET FROM THE EDGE OF PAVEMENT SHALL BE MAINTAINED ON ALL RESIDENTIAL SUBDIVISION SINGLE FAMILY DWELLINGS WILL BE REQUIRED IN ALL LOTS. STREETS. ADDITIONAL CLEAR ZONE MAY BE REQUIRED DEPENDING ON THE CATEGORY OF ROAD DESIGN. 28. THE MINIMUM HORIZONTAL RADIUS FOR CHANNELS IS 25'. CHANNEL JUNCTIONS SHALL USE A 30 DEGREE OR SMALLER ANGLE BETWEEN JOINING CHANNELS UNLESS AN ALTERNATIVE DESIGN IS APPROVED BY THE COUNTY ENGINEER. 12. COMPLIANCE WITH THE MINIMUM PAVEMENT WIDTH, SHOULDER WIDTH AND DITCH SECTIONS, AS SHOWN ON THE TYPICAL PAVEMENT 29 EC-3 TYPE A MAY BE ELIMINATED IN ROCK CONDITIONS, SUBJECT TO REVIEW IN FIELD WITH COUNTY STAFF. SECTION DETAIL, SHALL BE STRICTLY ADHERED TO. THE CROSS SLOPE SHALL BE MAINTAINED AS SHOWN ON THE PLANS. 13. ALL REQUIRED SIGNS (STOP, STREET NAME, SPEED LIMIT SIGNS, ETC.) ARE TO BE FURNISHED AND INSTALLED BY THE DEVELOPER PRIOR TO ACCEPTANCE. SIGNS AND THEIR INSTALLATION SHALL CONFORM TO "ALBEMARLE COUNTY ROAD NAMING AND PROPERTY NUMBERING VIRGINIA MANUAL FOR UNIFORM ORDINANCE AND MANUAL" AND THE LOCATIONS OF ALL SIGNS ARE TRAFFIC CONTROL DEVICES SHOWN ON THE PLANS. THE SPEED LIMIT IS TO BE POSTED AT 15 MPH. 14. ROAD PLAN APPROVAL IS SUBJECT TO FINAL SUBDIVISION PLAT VALIDATION. SHOULD THE FINAL PLAT FOR THIS PROJECT EXPIRE PRIOR TO SIGNING AND RECORDATION, THEN APPROVAL OF THESE PLANS SHALL BE NULL AND VOID. 15. TRAFFIC CONTROL OR OTHER REGULATORY SIGNS OR BARRICADES SHALL BE INSTALLED BY THE DEVELOPER WHEN, IN THE OPINION OF THE DIRECTOR OF ENGINEERING, OR THE DIRECTOR'S DESIGNEE, THEY ARE DEEMED NECESSARY IN ORDER TO PROVIDE SAFE AND CONVENIENT ACCESS. 16. USE VDOT STANDARD CD-1 OR CD-2 UNDERDRAINS UNDER THE SUBBASE MATERIAL AT ALL CUT AND FILL TRANSITIONS AND GRADE SAG POINTS. LEGEND VICINITY MAP STANDARDS AND SPECIFICATIONS IONS REVISIONS APP'JDLX®\VA LS W V= 2000' 1. VIRGINIA DEPARTMENT OF TRANSPORTATION (V.D.O.T.) ROAD AND BRIDGE SPECIFICATIONS, 1994. WATER LINE (EX. / PROP.) BOUNDARY / RIGHT-OF-WAY LINE WV® WMO WATER VALVE / METER I.F. IRON PIN FOUND FHA I.S. 2. VIRGINIA DEPARTMENT OF TRANSPORTATION (V.D.O.T.) ROAD AND BRIDGE STANDARDS, 2001. PLANNING YH-6- FIRE HYDRANT YARD HYDRANT IRON PIN SET SETBACK LINE EXIT 114 3. VIRGINIA DEPARTMENT OF CONSERVATION AND RECREATION, DIVISION OF SOIL AND WATER CONSERVATION, BOA® BLOW -OFF ASSEMBLY EASEMENT LIMITS �NTERSTATE64 SS VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK, THIRD EDITION, 1992. SANITARY SEWER LINE (EX. / PROP.) CENTERLINE ZONING COO CLEANOUT CONTOUR LINE (EX. / PROP.) MH" MANHOLE <--3: 1- F2.50 -- DEGREE / DIRECTION OF SLOPE TO C SD STORM LINE (EX. / PROP.) 479.70 + SPOT ELEVATION RSE. 631 'r�0� ENGINEERING DI F-'01 STORM INLET HP HIGH POINT <<F SHEETINDEX YD ® YARD DRAIN LP LOW POINT DS O DOWNSPOUT DITCH / SWALE �1 COVERSHEET I BUILDING CODE G GAS LINE (EX. / PROP.) WATER COURSE 1� PLAN NIASTE]R]PLAI�T 2 GVO GMO GAS VALVE/METER BM* BENCHMARK OHE OVERHEAD ELECTRIC (EX. / PROP.) CG-2 VDOT STD. HEADER CURB PLAN & PROFILE, STA 9+00 TO 23+00 3 UGE UNDERGROUND ELECTRIC (EX. / PROP.) CG-6 CG-12 VDOT STD. CURB & GUTTER VDOT STD. HANDICAP RAMP -F� PLAIT & PROFILE, STA 23+00 TO 37+00 4 FIRE SAFETY PPO POWER POLE HC HANDICAP PARKING SYMBOL dip LP-0- LIGHT POLE DIP DUCTILE IRON PIPE GUY-- GUY WIRE RCP REINFORCED CONCRETE PIPE ACSA EM o T❑ ELECTRIC METER TRANSFORMER CMP PVC CORRUGATED METAL PIPE POLYVINYLCHLORIDE PIPE * SITE OHT OVERHEAD COMMUNICATIONS (EX. / PROP.) HDPE HIGH -DENSITY POLYETHYLINE PIPE ARCHITECTURAL REVIEW BOARD UGT UNDERGROUND COMMUNICATIONS (EX. / PROP.) VC VITRIFIED CLAY PIPE PED ❑ UTILITY PEDESTAL FIFE FINISHED FLOOR ELEVATION TBR TO BE REMOVED TBT TO BE TRANSPLANTED TAYLOR'S GAP TBS TO BE SAVED F J.N. 0401 z DATE: 02-12-20 LOT 53 SEC. 2 ROSEMONT TMP 74-73 HALEY CHISHOU.1 AND MORRIS, INC D.B. 913 P. 393 D.B. 1250 P. 666 PLAT ao� END OF PHASE 1 IIIIII AS-BUILTS t\\\IiIIIIIII\1 \\t\ �- 111111 II IIII IIII I\\\\� 30.98 LF OF 18" CMP_�— I�IIIII�III II I\II\\\ \ @2.26% Tim INVIN=1152.9— \ INV OUT= 1152.2 \�\\� R �P \AAA VAA VAAAA A � \ RIP TRIP 74-24 W.L. CIEMENTS ESTATE Cjr c//0 tltoNR cIEMENTs 2392 CLEMENTS HOLLOW I -A nlun9T,EP. 530 VA. zz9u D.B. 294 P. 530 /W I I TMP 74-1aC, 18C1, 1BC2, 1aC3 THE ROCKS, LLD 13Q STONY MNT ROAD CHARLOTTESNLLE, VA. 22911 D.B. 24M P. 213 D.B. 1712 P. 494 D.B. 2436 P. J80 D.B. I712 P. 189 PLAT v I D.B. 24M P. 357 D.B. 1712 P. 157 D.B. 24M P. 354 D.B. 1603 P. 246 TMP 74-74 HALLY CHISHOLLI AND MORRIS, INC PO BOX 550 EARLYSMLLE, VA. 22936 / D.B. 913 P. 393 — AND MORRIS. INCM AND Box 5W IPF — PO BOX 550 tS 11C31 LLLV KJV ALL'J 100 200 ( IN FEET ) 1 inch = 100 ft. D.B. 913 P. 393 E7. 18C / 4 ,ac 1 IMP / \\ EX LOT2 IMP IXLOT3 1 _� i J BCL Yt: 18�'.i'Fe• / i /���CCCBBB==y,eS°s��9�9•� = — — — -1 \ I 1 \ I I ' I - � /i � \,7 \ \ \ \ \ \ \ \t `9c-"s7�7•6uei �`i � / �,�c�95Be:-' \ \ I / �/� — � \ \ \ \ \ \ VW, I I �1-nI8C3 \ EX. LOT 4 uP / A' 46 \ IMP 74-24 W.L CLEMENTS ESTATE 0 CR0MER CIEMENTS 2392 CLEMENTS HOLLOW LANE CHARLOTTESNLLE VA 22903 D.B. 294 P. 53d GRAPHIC SCALE ( IN FEET ) 1 inch = 100 ft. THE ROCKS RURAL PRESERVATION TRACT T��1Z A ENGINEERING AND LAND SOLUTIONS CIVIL ENGINEERS PLANNERS LAND SURVEYORS 415 4th STREET, NE CHARLOTTESVILLE, VIRGINIA 22902 PH. 434-244--0600 FAX 434-975-0900 �TH OF 'I�Ir�D SUI;Lv SCALE: 1=100' ISSUED: 2-15-05 DRAWN BY: ER]F REVISIONS: 1. 6-13-05 GENERAL REVISIONS 2. 1-27-06 GENERAL REVISIONS 3. 5-19-06 GENERAL REVISIONS 4. 6-12-06 AGENCY COMMENTS All rights reserved. No pan or me matenal protected by this copyright (plans, ideas, designs, sections or details expressed on these plans) may be reproduced, changed or utilized in any form or by any means, electronic or mechanical, including photocopying, scanning, or by any other means of retrieval system without written permission from Term Engineering and Land Solutions, PC. Also, these plans may not be assigned to a third party without first written authorization of Term Engineering and Land Solutions, PC. ® TERRA ENGINEERING AND LAND SOLUTIONS, PC SLIEET J.N. 0401 OF 4 /POS o, o, F O�B� Ali �O B ,2S9AA9TF �T O 6" #21A AGGREGATE / 6R ,off F9?�C' \ COMPACTED SUBGRADE ** A�"9!• I SF SO C'FS 1/� 4":1, • 1 ,1� 1 9 /II tii ,o f'.t / FIT sF9 0°01 e„oo„Q0000a„oo,Qoo,00gooao o,oaooQ op0000,a000, \_ 1 \2' x SF I 1P �FNPRR (6' W/GUARDRAIL) (6' W/GUARDRAIL) - _- - - * CROWN SLOPE TO BE INCREASED TO 3/8":' WHERE - - - ��\\ \ \ O>\ 39.04 LF OF 12" CMP ROAD GRADE EXCEEDS 12%. _ - - - - _ _ 08 \ \ \� F o ** IN SOIL CONDITIONS. MIN. SIDE SLOPE IN ROCK - - - - - - ` � 096� @13.32k \ \\ \ \Off\ c CONDITIONS SHALL BE 1/2:1 WITH SOME STABLE ROCK I INV IN=1215.6 OUTCROPS. \\/ 16 \ \ INV OUT=1210.4 a PORTION OF STREET SERVING MORE THAN 5 LOTS (9+00 EC-3, TYPE A \ \ \ \ \ \ ( TO 36+00) MAY BE REDUCED TO PROVIDE A 14' In \\ \ PAVEMENT WIDTH AT THE FOLLOWING APPROXIMATE 1 *I LO o A II(1'1 �yT III IIII� IIIII II IIIIIII III IIIIIII � IIIIIII I I II GRADE OUT DITCH, %0� /IIIIIII PROVIDE 2 SY RIP RAP, CLASS I, 18" DEPTH j I WITH FILTER FABRIC Ll EXISTING LOCATIONS: 9+00 TO 12+50, 17+30 TO 21+00, AND 24+00 i - - - - T - - \ 15 \Q�'. _ _. _... - w - \ \ _ "11\\��\\ a ,>.v. „ -.�^ •� \ h T CULVERT ��- -./-- \ S1 D T w_ ��-- -�•, TO 31+50. - = 1110 - 1 / / _ - - _ \ b 2' SHOULDER WIDTHS TO BE DETERMINED AND USED BY �� j \ \ �J / . - _ - ai - - 4- •� \\ \ FIELD ENGINEER. _ \ \o \ - / / - N _ w�_ - �FORSALESIGN \� \ \\ / % ji-- \� \ 1 /// / /---- bs�0-�_-- - N _----� \ / 1 I _ \ \\ TYPICAL STREET SECTION / / / /� - - / / // ----�- _--- z - ___ --- BEGINING OF' N1 \1 NOT TO SCALE PHASE 1 AS -BUILT x O Y' NOTE: LARGE VEHICLE PASSING ZONES, IN ADDITION TO- / I I fff - \ THE PRIVATE ENTRANCES AND CURVE WIDENING AT \ STOP SIGN STATION 28:50, WILL BE CONSTRUCTED TO PROVIDE AN I8' / // / / / / / / \ /�- y _ 29.98 LF OF 15" CMP // / / \I I I I I PAVEMENT WIDTH AT THE FOLLOWING APPROXIMATE o / / / // / / - GATE POSTS / / \p j / I I I LOCATIONS: 15+00 LEFT, 22+50 RIGHT, 34+00 RIGHT, 38+5 @ 7.67 /o 10 LEFT, AND 46+50 LEFT OR RIGHT. INV IN=1127.3 INV OUT=1125.0 - - - I 41.50 LF OF 15" CMP4<1 INV IN=1199.9 /� / ,R=zoo.00' \ EC-3, TYPEA / /: I INV OUT=1197.8 -------- \ A=27.05' \-\ \ �A=7*44'59" - / 1/�0 9Aj EC-2 N --------- 0� \ s�8. �� % /% %,�� / �1 17 \ \ / ( --- �� � / r /f /lj 11//lllll /l ° �[y1DE / �14.52'� 1.11 yL.� WIDE v 1 +0018 \I I GRADE OUT - DITCH 4 13+Q0 y 2� .5 j/ //EC-3.TYPE A, // / // //?/// / WOODEN / GUARDRAIL,TYP. 77EC-z PRIVATE 28. F495 /�6i/// PROPERTY SIGN rf2666 �S I� 7D 'It Ph-ans //,i,/,//i//;/////� / GRAPHIC SCALE / 50 0 25 50 100 200 7� 9? I SAT r 02-12-20 I ( IN FEET ) I inch = 50 ft. 1230 1220 1210 1200 1190 1180 1170 1160 1150 1140 9 \ AQ 123011 PVI STA = 18+50 PVI ELEV = 1113.70 A = 4.06 RO9p 12201140 .0 100.0 0' VC PVI STA = 19+ 0 d - PRO aOSED GRADE -C =NTERLINE A = - -8.57 00 K = 10.6918 EXI ING GROUND - C NTERLINE 100.0000' VC \ EXI ING GROUND-2 'LEFT 121 1130 \ \\ \\\ a > a N LP EL =V= 1078.59 \ + v LP ST = 22+48.16 \ PVI ST = 13+50 PROPOSED CUL ERT #1 \ M � + W c0 PROPO EDGRADE -CEN ERLINE PVI S PVI ELEV A=22+60.50 = 1066.94 5 PVI ELEV = 1163.70 12001120 w A= 4.5 a a EXISTINr 3 GROUND -CEN RLINE K 9.5912 K = \ a - p> EXISTIN GROUND - 20' L T A3s O tt O EXISTIN GROUND - 20' RI 14T 30 3.0000, VC EXISTING CULV RTJ 0 100.00 DO' VC \ N _O 11901110 w� 0 d o \ O + c \ loo 00 a Uj v 11801100 + cc a ui > \ do O O W In In 7 11701090 a W 5 a 11601080 \\ 1070 O 0 N M CN N N N NO N O M M co co N N N M O0 O 0 O 0 O oo O r- O� O NO 0O 12 + 13 + 14 + 15 + 16 + 17 + 18 + 19 + 20 + 21 + 22 + 1150 1140 1130 1120 1110 1100 1090 1:1 1070 1060 TE�RA ENGINEERING AND LAND SOLUTIONS CIVIL ENGINEERS PLANNERS LAND SURVEYORS 415 4th STREET, NE CHARLOTTESVILLE, VIRGINIA 22902 PH. 434-244--0600 FAX 434-975-0900 �TH OF 'I�Ir�D SURV�t SCALE: ]H[ 1=50' V 1=10' ISSUED: 2-15-05 DRAWN BY: ERF REVISION'S: 1. 6-13-05 GENERAL REVISIONS 2. 1-27-06 GENERAL REVISIONS 3. 5-19-06 GENERAL REVISIONS 4. 6-12-06 AGENCY COMMENTS 5. 9-08-06 GENERAL REVISIONS All ngnts reserved. NO pan or the matenal protected by this copyright (plans, ideas, designs, sections or details expressed on these plans) may be reproduced, changed or utilized in any form or by any means, electronic or mechanical, including photocopying, scanning, or by any other means of retrieval system without written permission from Term Engineering and Land Solutions, PC. Also, these plans may not be assigned to a third party without first written authorization of Term Engineering and Land Solutions, PC. 0 TERRA ENGINEERING AND LAND SOLUTIONS, PC SI IEET J.N. 0401 OF 4 Asp-miBuilt Plans ATE �������® // // /////// �p///p,/llltil/ /// ///��,1 Ap SEE DETAIL ULVERT#2 to v l�u NV. IN-1153.47 Tf 1150.00 8� qMP @ 1.5% TJ(OI 111 11 l l 11 'r: YDpN EC OT ES-1 IIIIIIII �I��111111 111 11 llll .'/" 11 /ll ` � I I� III IIIIIIIIIIIIIIIIIIII///�//// /, III I I 30.98 LF OF 18" CMP @ 2.26% I I I I I I I I I I I I I I I I I I I I I I I I I I I I I II I I I I I I INV IN=1152.9 III I I I I I I I I I I I I I I A11�rrI INV OUT=1152.2 IIIIIII III III►IIIII1111IIIIIIII.��" o ��' IIIIIII �. I �� IIIi,,�t IIII�IjII�IIIIIIII�Ijjll�l�l f` IIIII III ,I i I I jl\I\\ \C ` Iliillllll�l�llll II llllll , a, IIIIIII; \ \� \ \`\`\\ \ TYPE IIIIIIIIIIIIIIIIIIIIIIII h' IIII'lll'lll,'I :„. *� \\\\\\\\\ II II I II I I II \\' \\ \ \\ \\ EC-3.TY TYPE \ \\ EC-31 TYPE RIPRAP C \� c Arcr 1ST\0�, �l 1150 1140 1130 1120 1110 1100 1090 1:1 1070 W110601 49.0 LF-18 CMP@ ­. �M END SECTIONS: VID /C OUTLET: VDOT EC-1 — \ � I \ RIP RAP DITCH III II 1 12" DEPTH I 1 �R"TRI!^I(AIFCC I I i CULVERT#3 I IIIII III 11 1 11 INV. INV. OUT -1097. 50 I 1 I 1.I 'C�`�� I I I I I Q \ %\ An- RAN f l / / / / / // / / / i/ * CROWN SLOPE TO BE INCREASED TO 3/8"A' WHERE ROAD GRADE EXCEEDS 12%. ** IN SOIL CONDITIONS. MIN. SIDE SLOPE IN ROCK CONDITIONS SHALL BE 112:1 WITH SOME STABLE ROCK OUTCROPS. e PORTION OF STREET SERVING MORE THAN 5 LOTS (9+00 TO 36+00) MAY BE REDUCED TO PROVIDE A 14' PAVEMENT WIDTH AT THE FOLLOWING APPROXIMATE LOCATIONS: 9+00 TO 12+50, 17+30 TO 21+00, AND 24+00 TO 31+50. to 2' SHOULDER WIDTHS TO BE DETERMINED AND USED BY FIELD ENGINEER. TYPICAL STREET SECTION NOT TO SCALE NOTE: LARGE VEHICLE PASSING ZONES, IN ADDITION TO THE PRIVATE ENTRANCES AND CURVE WIDENING AT STATION 28:50, WILL BE CONSTRUCTED TO PROVIDE AN 18' PAVEMENT WIDTH AT THE FOLLOWING APPROXIMATE LOCATIONS: 15+00 LEFT, 22+50 RIGHT, 34+00 RIGHT, 38+50 LEFT, AND,46+�50 LEFT OR RIGHT. / I / I I I I I I I I I I I DETAIL SCALE: 1" = 20' N W of u Lu \\\\ \ GRAPHIC SCALE ( IN FEET ) 1 inch = 50 ft. a o_ Col 1501210 101270 M M / / IL PVI STA = 2 9+89 U a PVI ELEV = 1160.95 PR POSED GRADE - ENTERLINE 14 1200 A = 10.14 12001260 PROPOS D GRADE - CENTE RLINE K = 12.9605 EXI 5TING GROUND - GENTERLINE 142.5600' C / EXI 3TING GROUND - 0' LEFT O O / PVI TA = 33+25 EXI TING GROUND- 0' RIGHT v EXISTING EXISTING GROUND -CENT GROUND - 20' LE LINE - fob �- PVI E EV = 1218.07 EXISTING GROUND - 20' RIG T / 11301190 ° 11901250 A 10.2494 10. 7 W N K = 9.7567 a a n / + ' 100.000 VC 11201180 a 11801240 PVI ST A= 27+13.E 5 PVI EL V = 11 3. 9 1- ir A - 0.25 M 04 04 K 10.06 / n _ /� PROPOSED RADE - CENTERL NE H W 11101170 11701230 / N W EXISTING G EXISTING GF OUND - CENTERL OUND - 20' LEFT E a_ / O / + d j EXISTING GF OUND - 20' RIGHT �— JI W U) ( 0 / 5 11001160 11601220 01 / PROPOSED C 'ERT #a oi LU H 1090115 1150 10 PR DPOSED CULVER #2 1080 40 11401200 LC + co M CS N N 0 10701130 2 a 11301190 co O l Ci pq co co Ci CM O O� N N � V� � O n n W^ aO Oco O CM fM M M 10 O OH O M M r,.f co �� � M M � I M C4 N M N M N N coCID N O O O NcliI M + 24 + 25 + 26 + 27 + + 28 + 29 + 30 + 31 + 32 + 33 + 34 + 35 + 36 + 1270 1260 1250 1240 1230 1220 1210 1200 1190 1180 T��.A ENGINEERING AND ]LAND SOLUTIONS CIVIL ENGINEERS PLANNERS LAND SURVEYORS 415 4th STREET, NE CHARLOTTESVILLE, VIRGINIA 22902 PH. 434-244-0600 FAX 434-975-0900 Y;YH o F' Dj SCALE: H 1=50' V I"=10' ISSUED: 2-15-05 DRAWN BY: ERF REVISIONS: 1. 6-13-05 GENERAL REVISIONS 2. 1-27-06 GENERAL REVISIONS 3. 5-19-06 GENERAL REVISIONS 4. 6-12-06 AGENCY COMMENTS 5. 9-08-06 GENERAL REVISIONS All rights reserved. No part of the material protected by this copyright (plans, ideas, designs, sections or details expressed on these plans) may be reproduced, changed or utilized in any form or by any means, electronic or mechanical, including photocopying, scanning, or by any other means of retrieval system without written permission from Terra Engineering and Land Solutions, PC. Also, these plans may not be assigned to a third party without first written authorization of Terra Engineering and Land Solutions, PC. ® TERRA ENGINEERING AND LAND SOLUTIONS, PC SHEET J.�. 0101 OF 4