HomeMy WebLinkAboutARB202000076 Staff Report 2020-07-31ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB-2020-76: Flow Auto Porsche, Audi, Volkswagen, Mazda Review Type Second review of a site plan amendment and architectural designs Parcel Identification 07800000000600 and 07800000000700 Location 1300 Richmond Road Zoned Highway Commercial (HC)/Entrance Corridor (EC) Owner/Applicant Flow 1300 Richmond LLC/brw architects (David Timmerman) Magisterial District Rivanna Proposal To establish a new auto dealership with renovated and new buildings and parking. Context The site is located in the Pantops commercial area (Figure 1), with a number of other auto dealerships in the immediate vicinity. To the immediate west, construction is underway on the Pantops Comer development, including a Holiday Inn Express hotel, a storage facility, and a Wawa convenience store and fuel canopy. Visibility The existing buildings are readily visible from the Rt. 250 Entrance Corridor from approximately the Virginia National Bank building at the west to the Suntrust Bank and Car Max at the east. The existing used car building is just visible above and between the buildings at 1289, 1311, and 1321 Stony Point Rd., and at the new entrance to the Pantops Corner development on Rt. 20. The proposed buildings will have a similar level of visibility as the existing ones. The construction of the Pantops Holiday Inn Express and the Pantops Comer Self Storage buildings will limit some of this visibility from Rt. 20, but will not eliminate visibility. ARB Meeting Date August 3, 2020 Staff Contact Margaret Maliszewski 3LY j25 789-01- 323 (y /7 BG2 O/ - 'O _ 78-58G1 J - 78-58G3 - _ 315, 0 J � _ r 1321 J — 78-6 1304 78-5E - - - 78-5C 78-4A 1311 78-7 294 78-5A r 2289 1300 ' 78-SG �, 78-SF 78-58 1242 e aos/ / 15 Richmond RA 3� �` �o 10 1 —' _J 11 76.15D ]8-15� ]B-ISE 1313 irr 4 1, — 1289 1295 --•-•'-J 78-17H 1(�'`11 IIII j�7816 — 78-158 125 �� 1357 Figure 1: Map showing a portion of the Pantops commercial area. The current Flow proposal is located on the two parcels (#6 and #7) just west (left) of Town and Country Lane. The existing Flow dealership occupies parcels # 15D and #15E on the south side of Rt. 250.Other auto dealerships and showroom/service buildings occupy parcels #5G, 15, and 14 (and additional parcels to the east). 2 SITEXROJECT HISTORY In 1995, the ARB reviewed and approved a proposal to establish sales and display parking on Tax Map 78, Parcel 6 for Brady Bushy Ford with a new sales office, a new building for car washing, a reconfiguration of the parking area, and a renovation of the fagade of the existing building. Several signs were reviewed in 2000, 2005, 2009 and 2013. An application to redevelop this site (parcels 6 and 7) was first submitted as ARB-2019-154, but the applicant requested deferral of that application, then submitted the current application ARB-2020-32 in its place. The ARB has completed several reviews of designs for Audi, Porsche, VW and Mazda buildings on other parcels in the Pantops area. In 2016 the ARB reviewed proposals for an Audi showroom on parcel 15E. Additional plans were submitted in 2017 and a Certificate of Appropriateness was issued in 2018, but the project was not constructed. The ARB completed a work session for a trademark design Porsche showroom to replace the existing Flow building on the south side of Rt. 250 in early 2019. Rim - Subsequent conceptual reviews were held in 2019 for side -by -side Audi and Porsche showrooms to replace the existing Flow building. The ARB approved a design with conditions in June 2019. The ARB reviewed proposals for Mazda and VW showrooms at the comer of Rts. 20 and 250 in May and August of 2019. That proposal did not move forward. On May 18, 2020, the ARB completed a conceptual review of the proposal to modify the Pantops property previously occupied by Malloy Ford with renovated and new buildings and parking. Comments from that meeting are included in the Analysis section of this report. ANALYSIS REF GUIDELINE 5/18/20 CURRENT ISSUE CURRENT RECOMMENDATION RECOMMENDATION ft ose; Conspalibifily with significant historic sites: I The goal of the regulation of the design of development within the designated See recommendations, The proposed building designs do not See recommendations, Entrance Corridors is to insure that new development within the corridors reflects below. reflect the traditional architecture of the below. the traditional architecture of the area. Therefore, it is the purpose of ARB review area, but they are consistent with some and of these Guidelines, that proposed development within the designated Entrance buildings in the immediate vicinity (most of Corridors reflect elements of design characteristic of the significant historical which were originally constructed prior to landmarks, buildings, and structures of the Charlottesville and Albemarle area, and the establishment of the Entrance Corridors to promote orderly and attractive development within these corridors. Applicants and were subsequently renovated following should note that re lication of historic structures is neither required nor desired. ARB review and approval). Orderly and attractive development could be promoted 2 Visitors to the significant historical sites in the Charlottesville and Albemarle area experience these sites as ensembles of buildings, land, and vegetation. In order to with improved landscaping and appropriate accomplish the integration of buildings, land, and vegetation characteristic of these lighting. sites, the Guidelines require attention to four primary factors: compatibility with significant historic sites in the area; the character of the Entrance Corridor; site develo ment and la out; and landscaping. 3 New structures and substantial additions to existing structures should respect the traditions of the architecture of historically significant buildings in the Charlottesville and Albemarle area. Photographs of historic buildings in the area, as well as drawings of architectural features, which provide important examples of this tradition are contained in Appendix A. 4 The examples contained in Appendix A should be used as a guide for building design: the standard of compatibility with the area's historic structures is not intended to impose a rigid design solution for new development. Replication of the design of the important historic sites in the area is neither intended nor desired. The Guideline's standard of compatibility can be met through building scale, materials, and forms which may be embodied in architecture which is contemporary as well as traditional. The Guidelines allow individuality in design to accommodate varying tastes as well as s ecial functional requirements. Structure design 9 Building forms and features, including roofs, windows, doors, materials, colors and Revise the demolition plan The portion of the building at 1300 Clarify whether the textures should be compatible with the forms and features of the significant historic to identify the portions of Richmond Road that is to be demolished is framework that some buildings in the area, exemplified by (but not limited to) the buildings described in the existing buildings that now identified on the demolition plan. drawings show extending Appendix A [of the design guidelines]. The standard of compatibility can be met will be demolished. above the Porsche through scale, materials, and forms which may be embodied in architecture which is The Mazda design has been revised to break entrance is proposed. If it contemporary as well as traditional. The replication of important historic sites in Consider revising the up the scale of the building by lowering the is, adjust all relevant Albemarle County is not the objective of these guidelines. Mazda and VW designs to height of its eastern half by 4' (from 26' to drawings to show the break up the building 22'). The VW building has not been framework and provide masses, by establishing a revised, but it sits at a lower elevation than additional information to series of building elements the Mazda building, and its top elevation is clarify its purpose, that are set back from one 7' below that of the east side of the Mazda structure and appearance. another. building. This progressive reduction in height establishes a related series of Consider revising the east Reduce the top-heavy building blocks, and the white brick portion interior wall of the upper appearance of the brick- of the Mazda building has less of a top- level showroom from a faced front of the Mazda heavy appearance. white finish to the warm elevation. wood -tone tile proposed o The elevation drawings show that the east the north wall. Revise the drawings to elevation of the Porsche building will be show how the east elevation painted dark gray to match the metal panels of the Porsche building will used elsewhere on the building. be refinished. The proposed buildings do not relate to adjacent sites — the Guadalajara restaurant to the east or the Wawa gas station and 5 It is also an important objective of the Guidelines to establish a pattern of None. compatible architectural characteristics throughout the Entrance Corridor in order to convenience store under construction to the achieve unity and coherence. Building designs should demonstrate sensitivity to west. They are more like the Flow and other nearby structures within the Entrance Corridor. Where a designated corridor is Toyota buildings across Rt. 250 to the substantially developed, these Guidelines require striking a careful balance between south. harmonizing new development with the existing character of the corridor and achievibility with the significant historic sites in the area. Some of the drawings now show the Porsche building with a framework structure rising above the roofiine at the 10 Buildings should relate to their site and the surrounding context of buildings. 11 The overall design of buildings should have human scale. Scale should be integral See #9. to the building and site design. center of the building. Its structure and purpose are not entirely clear. The interior of the Mazda building will have an impact on the corridor due to the extensive use of glass on the west and south elevations. The north wall of the upper level showroom is proposed to be faced with a warm, wood -tone tile, and the east wall is illustrated in a bright white finish. Revising the white to the warm wood tone could produce a more appropriate appearance for the EC. 12 Architecture proposed within the Entrance Corridor should use forms, shapes, scale, None. The Audi and Porsche buildings are None. and materials to create a cohesive whole. connected by a hyphen. The Mazda and VW buildings are not connected with each other 14 Arcades, colonnades, or other architectural connecting devices should be used to unify groups of buildings within a development. or Audi/Porsche. The consistent use of geometric forms, neutral colors, and similar sizes is expected to establish a coordinated appearance on site. These features are also consistent with the BMW, Flow and Toyota sites across the street. 13 Any appearance of "blankness" resulting from building design should be relieved See #9. The blankness of the Mazda design has None. using design detail or vegetation, or both. been reduced with the reduction in height of the white brick wall. 15 Trademark buildings and related features should be modified to meet the The proposed buildings are all versions of requirements of the Guidelines. standard trademark designs that have been adapted to varying degrees to meet site limitations. 16 Window glass in the Entrance Corridors should not be highly tinted or highly Provide the standard glass A glass note addressing VLT and VLR has None. reflective. Window glass in the Entrance Corridors should meet the following note on the Mazda and VW been added to the plan. GLASS SAMPLE? criteria: Visible light transmittance (VLT) shall not drop below 40%. Visible light architectural drawings. reflectance (VLF shall not exceed 30%. Specifications on the proposed window Indicate if proposed glass is lass should be submitted with the applicationforfinal review. tinted. Provide samples. Accessory structures and equipment 17 Accessory structures and equipment should be integrated into the overall plan of Show how the design of the The plans indicate that Mazda equipment Show how the design of development and shall, to the extent possible, be compatible with the building new buildings/ additions will be located in a recess on the west the new buildings/ desiRns used on the site. will screen the view of equipment from the street. elevation of the building where it will not be visible from the street. A section shows that additions will screen the view of equipment from 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate siting, these features will still have a negative visual impact rooftop equipment on the VW building will the street, including on the Entrance Corridor street, screening should be provided to eliminate visibility. a. not be visible when standing on the street further east on the EC Loading areas, b. Service areas, c. Refuse areas, d. Storage areas, e. Mechanical directly in front of the building. Similar where the views are from equipment, sections are shown for Audi and Porsche higher elevations down f. Above -ground utilities, and g. Chain link fence, barbed wire, razor wire, and where the mechanical units are placed on a onto the buildings. similar security fe ing devices. lower elevation of the roof These drawings do not make it clear that equipment will not 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may consist of. a. Walls, b. Plantings, and c. be visible from further east on the corridor Fencin . where there is a clear view down onto these buildings. 20 Surface runoff structures and detention ponds should be designed to fit into the natural None. topography to avoid the need for screening. When visible from the Entrance Corridor street, these features must be frilly integrated into the landscape. They should not have The equipment note has been added to the the appearance of engmeered features. architectural plans. 21 The following note should be added to the site plan and the architectural plan: Add the standard "Visibility of all mechanical equipment from the Entrance Corridor shall be mechanical equipment note eliminated." to the architectural plans. Li htin General Guidelines 22 Light should be contained on the site and not spill over onto adjacent properties or Provide a revised Where spillover exceeds .5 fc along Rt. 250, None. streets; photometric plan showing the illumination appears to be from existing combined existing and non -conforming fixtures. proposed illumination. If combined existing and proposed spillover exceeds .5 fc at the property line, also provide a photometric plan showing only the existing illumination. 23 Light should be shielded, recessed or flush -mounted to eliminate glare. All fixtures None. The proposed parking lot pole light fixtures None. with lamps emitting 3000 lumens or more must be full cutoff fixtures. are full cutoff. 24 Light levels exceeding 30 footcandles are not appropriate for display lots in the See #22. The maximum light level is shown as 24.7 None. Entrance Corridors. Lower light levels will apply to most other uses in the Entrance fc, with some of this produced by existing Corridors. non -conforming fixtures. 25 Light should have the appearance of white light with a warm soft glow, however, a Identify on the lighting plan A note on the lighting plan states that the None. consistent appearance throughout a site or development is required. Consequently, the color temperature of the color temperature for the new fixtures will if existing lamps that emit non -white light are to remain, new lamps may be existing and proposed be 3000K. The color range of existing required to match them. fixtures. Provide for a fixtures is noted as 3000-6000K, so 3000K warm white appearance for new fixtures is appropriate. consistent throughout the site. 26 Dark brown, dark bronze, or black are appropriate colors for free-standing pole Identify existing and Proposed finish is gray. This is meant to None. mounted light fixtures in the Entrance Corridors. proposed pole and fixture match existing fixtures, so this deviation colors on the lighting plan. from standard bronze or black is Provide for a consistent appropriate. appearance. 27 The height and scale of freestanding, pole -mounted light fixtures should be None. A note on the plan states that all lights are to Consider a 15' height for compatible with the height and scale of the buildings and the sites they are be mounted at 20' high. Existing pole new pole lights. illuminating, and with the use of the site. Typically, the height of freestanding pole- fixtures are 15' high. Although 20' is an EC mounted light fixtures in the Entrance Corridors should not exceed 20 feet, standard, 15' would provide for greater including the base. Fixtures that exceed 20 feet in height will typically require coordination. additional screening to achieve an appropriate appearance from the Entrance Corridor. 28 In determining the appropriateness of lighting fixtures for the Entrance Corridors, Eliminate the illumination The illumination trough note has been None. the individual context of the site will be taken into consideration on a case by case troughs and related fixtures eliminated from the drawings. basis. from the VW building design. 29 The following note should be included on the lighting plan: "Each outdoor Add the standard lighting The lighting note is on the plan. None, luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a note to the plan. full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or Waal areas zonina districts shall not exceed one half footcandle." 30-31 Guidelines for the Use of Decorative Landscape Lighting Provide complete Three wall -mounted lights are proposed for None. information on building- the back of the Porsche/Audi building. mounted lights for review. These are not expected to have an impact on the EC. No other fixtures are shown. Landscaping 7 The requirements of the Guidelines regarding landscaping are intended to reflect the Revise the plans to make The plan is legible. Revise the landscape plan landscaping characteristic of many of the area's significant historic sites which is existing landscaping and to show a consistent row characterized by large shade trees and lawns. Landscaping should promote visual related notes legible. Large shade trees and ornamentals are of shrubs along the EC order within the Entrance Corridor and help to integrate buildings into the existing provided along the frontage of parcel 6 at frontage and along the environment of the corridor. Provide large shade trees 35' on center, and the size and spacing required. However, all this planting appears to be within existing western perimeter of the parking lot located 8 Continuity within the Entrance Corridor should be obtained by planting different types of plant materials that share similar characteristics. Such common elements interspersed ornamentals, easements. between the Mazda/VW allow for more flexibility in the design of structures because common landscape along the frontage of parcel " ldings and Rt. 250, features will help to harmonize the appearance of development as seen from the 6, clear of utilities and 2 at planting. street upon which the Corridor is centered. easements. - 4 Wow how landscaping 32 Landscaping along the frontage of Entrance Corridor streets should include the following: Revise the plan to show a tilities are being a. Large shade trees should be planted parallel to the Entrance Corridor Street. Such consistent row of shrubs mated. trees should be at least 3% inches caliper (measured 6 inches above the ground) and along the frontage of should be of a plant species common to the area. Such trees should be located at parcels 6 and 7. least every 35 feet on center. b. Flowering ornamental trees of a species common to the area should be interspersed Revise the landscape plan among the trees required by the preceding paragraph. The ornamental trees need not to show how the sloped Deciduous shrubs are interspersed along alternate one for one with the large shade trees. They may be planted among the large frontage will be planted to parcel 7; three are proposed in a group near shade trees in a less regular spacing pattern. achieve an appropriate the west end of the frontage of parcel 6, and c. In situations where appropriate, a three or four board fence or low stone wall, appearance. some shrubs are grouped in the island typical of the area, should align the frontage of the Entrance Corridor street. between the entrances from Rt. 250. A d. An area of sufficient width to accommodate the foregoing plantings and fencing consistent row is not provided. The ground should be reserved parallel to the Entrance Corridor street, and exclusive of road cover on parcel 6 is proposed to be right-of-way and utility easements. replaced. 33 Landscaping along interior roads: None. There are no interior roads. None. a. Large trees should be planted parallel to all interior roads. Such trees should be at least 2% inches caliper (measured six inches above the ground) and should be of a plant species common to the area. Such trees should be located at least every 40 feet on center. 34 Landscaping along interior pedestrian ways: None. There are no pedestrian paths, but each None. a. Medium trees should be planted parallel to all interior pedestrian ways. Such building is fronted by a sidewalk. trees should be at least 2%: inches caliper (measured six inches above the ground) and should be of a species common to the area. Such trees should be located at least every 25 feet on center. 35 Landscaping of parking areas: Revise the landscape plan Shrubs are interspersed along the EC Revise the landscape plan a. Large trees should align the perimeter of parking areas, located 40 feet on center. to show the required frontage, but they are not shown in a to show a consistent row Trees should be lanted in the interior of parking areas at the rate of one tree for perimeter parking lot and consistent row. of shrubs along the EC every 10 parking spaces provided and should be evenly distributed throughout the interior parking lot tree frontage and along the interior of the parking area. planting at the required Parking spaces are identified as to type. western perimeter of the b. Trees required by the preceding paragraph should measure 2% inches caliper sizes, and shrubs along the parking lot between the (measured six inches above the ground); should be evenly spaced; and should be of southern parking lot Planting along the 7-space row includes two Mazda/VW buildings and a species common to the area. Such trees should be planted in planters or medians perimeter, 24" at planting. London plane trees, one Redbud, one Rt. 250, 24" at planting. sufficiently large to maintain the health of the tree and shall be protected by Dogwood, six Hydrangea, and two groups curbing. Revise the site plan to of Itea. One of the London Plane trees is Show how landscaping c. Shrubs should be provided as necessary to minimize the parking area's impact on identify all parking spaces directly under an overhead utility line. The and utilities are being Entrance Corridor streets. Shrubs should measure 24 inches in height. by type (i.e., customer, other trees are close to other utilities. coordinated. employee, storage/display, awaiting repair, etc.). Planting bed width for the 10-space row is 8'. Provide appropriate landscaping along the 7- Perimeter trees are not provided along the space parking row located expanded parking at the rear of the Mazda closest to the EC. and VW buildings. No landscaping is existing or proposed along the western Provide adequate width in parking perimeter at the front of the site. the planting island along Both shrubs and trees would be appropriate, the 10-space row to though shrubs might be better suited to the accommodate large shade available planting area. trees. Provide landscaping along frontages, perimeters and interior to the site to offset visual impacts. 36 Landscaping of buildings and other structures: Consider adding a tree in Two Birch trees are shown in the area None. a. Trees or other vegetation should be planted along the front of long buildings as the area where the hyphen where the hyphen separates the Audi and necessary to soften the appearance of exterior walls. The spacing, size, and type of separates the Audi and Porsche showrooms. such trees or vegetation should be determined by the length, height, and blankness Porsche showrooms. of such walls. b. Shrubs should be used to integrate the site, buildings, and other structures; dumpsters, accessory buildings and structures; "drive thru" windows; service areas; and signs. Shrubs should measure at least 24 inches in height. 37 Plant species: a. Plant species required should be as approved by the Staff based None. Proposed plants are on the various lists. None. upon but not limited to the Generic Landscape Plan Recommended Species List and Native Plants or Vir nia Landscapes (Appendix D . 10 38 Plant health: The following note should be added to the landscape plan: "All site None. The note appears on the plan. None, plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and onl to support the overall health of theplant." Site Development and layout Development pattern 6 Site development should be sensitive to the existing natural landscape and should See #35. The existing and proposed buildings are See #35. contribute to the creation of an organized development plan. This may be oriented parallel to the EC. The Audi accomplished, to the extent practical, by preserving the trees and rolling terrain addition brings the building closer to the typical of the area; planting new trees along streets and pedestrian ways and street. There is wooded area at the back of choosing species that reflect native forest elements; insuring that any grading will the site, some of which will be removed for blend into the surrounding topography thereby creating a continuous landscape; expanded parking area and travelway, and a preserving, to the extent practical, existing significant river and stream valleys new connection to the property to the west. which may be located on the site and integrating these features into the design of Traveling west on Rt. 250 through Pantops, surrounding development; and limiting the building mass and height to a scale that a view of the mountains is available. The does not ove ower the natural settings of the site, or the Entrance Corridor. proposed development will be visible to westbound traffic beginning at the Suntrust 39 The relationship of buildings and other structures to the Entrance Corridor street and to other development within the corridor should be as follows: Bank and CarMax at the east, with the a. An organized pattern of roads, service lanes, bike paths, and pedestrian walks mountains as a backdrop. Landscaping can should guide the layout of the site. help offset visual impacts of the proposed b. In general, buildings fronting the Entrance Corridor street should be parallel to development. the street. Building groupings should be arranged to parallel the Entrance Corridor street. c. Provisions should be made for connections to adjacent pedestrian and vehicular circulation systems. d. Open spaces should be tied into surrounding areas to provide continuity within the Entrance Corridor. e. If significant natural features exist on the site (including creek valleys, steep slopes, significant trees or rock outcroppings), to the extent practical, then such natural features should be reflected in the site layout. If the provisions of Section 32.5.2.n of the Albemarle County Zoning Ordinance apply, then improvements required by that section should be located so as to maximize the use of existing features in screening such improvements from Entrance Corridor streets. f The placement of structures on the site should respect existing views and vistas on and around the site. Site Grading 40 Site grading should maintain the basic relationship of the site to surrounding conditions None. Grading is proposed to establish additional None. by limiting the use of retaining walls and by shaping the terrain through the use of parking on parcel 6 behind the proposed smooth, rounded land forms that blend with the existing terrain. Steep cut or fill Mazda and VW buildings. Retaining walls sections are generally unacceptable. Proposed contours on the grading plan shall be 6' and 13' high are proposed. This parking rounded with a ten foot minimum radius where they meet the adjacent condition. Final is not expected to be visible from Rt. 250. grading should achieve a natural, rather than engineered, appearance. Retaining walls 6 The Pantops Corner development is feet in height and taller, when necessary, shall be terraced and planted to blend with the expected to screen much of the Flow site landscape. from Rt. 20, but not all of it. (The Ford used cars building is currently visible from Rt. 20. 41 No grading, trenching, or tunneling should occur within the drip line of any trees or Revise the site plan to show Tree lines to remain and tree protection None. other existing features designated for preservation in the final Certificate of tree lines to remain and tree fencing have been added to the plan. Appropriateness. Adequate tree protection fencing should be shown on, and protection fencing. coordinated throughout, the grading, landscaping and erosion and sediment control Tans. 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected on the site prior to any grading activity on the site. This protection should remain in place until completion of the development of the site. 43 Preservation areas should be protected from storage or movement of heavy e ui ment within this area. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should None. Much of the site is already developed. A None. be incorporated into the finished site to the extent possible. detention pond is proposed at the north end of the site. It is not expected to be visible from the street. SIGNS Note that a Comprehensive Because the development consists of Submit a Comprehensive Sign Plan must be reviewed multiple buildings, a Comprehensive Sign Sign Plan for review by and approved with the Final Plan must be reviewed and approved by the the ARB. Approval of the Site Plan submittal. ARB with this application. CSP is required prior to final approval of this application. 12 SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Architecture: the massing of the Mazda and VW designs; the white finish for the Mazda interior wall. 2. Landscaping: coordination of landscaping and utilities; landscaping along the western parking lot perimeter; shrubs along the EC frontage. 3. The requirement for a Comprehensive Sign Plan. Staff recommends the following changes to the proposal: 1. Clarify whether the framework that some drawings show extending above the Porsche entrance is proposed. If it is, adjust all relevant drawings to show the framework and provide additional information to clarify its purpose, structure and appearance. 2. Consider revising the east interior wall of the upper level showroom from a white finish to the warn wood -tone tile proposed o the north wall. 3. Show how the design of the new buildings/additions will screen the view of equipment from the street, including further east on the EC where the views are from higher elevations down onto the buildings. 4. Consider a 15' height for new pole lights. 5. Revise the landscape plan to show a consistent row of shrubs along the EC frontage and along the western perimeter of the parking lot located between the Mazda/VW buildings and Rt. 250, 24" at planting. 6. Show how landscaping and utilities are being coordinated. 7. Submit a Comprehensive Sign Plan for review by the ARB. Approval of the CSP is required prior to final approval of this application. ATTACHMENTS Attachment A: Applicant's site plan submittal Attachment B: Applicant's architectural plan submittal 13 TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date/Revision Date ARB Concept Review Submission: Aerial perspective renderings, Existing site plan. 6/22/2020 Audi & Porsche: Existing and new front perspective, Existing plan, New plan, New front perspective, Audi Porsche front perspectives, Existing and New perspectives looking west and east from Rt. 250, Elements of entry corridor guidelines. Mazda & Volkswagen: Existing & new perspective looking northwest from Rt. 250, Project narrative, Existing & new front perspective from Rt. 250, Existing perspective entry looking west, Mazda perspective looking west and east, Existing perspectives looking northeast and west, New perspective VW front and East side, Mazda and VW front building elevations, Elements of entry corridor guidelines, Site landscape (2). Site Plan 6/22/2020 C1 Cover C2 Site Overview C3 Existing Conditions & Demolition C4 Site Plan C5 Grading & Utilities C6 Landscaping Plan C7 Landscaping Details C8 Lighting Plan C9 Lighting Details C10 Sight Distance C11 Storm Details C12 Site Details C13 Site Details 14