HomeMy WebLinkAboutSP200400036 Legacy Document 2006-01-12 (5)STAFF PERSON: JUDITH WIEGAND
PLANNING COMMISSION: JUNE 21, 2005
BOARD OF SUPERVISORS: JULY 13, 2005
ZMA 2004-11 CHARLOTTESVILLE POWER EQUIPMENT
SP 2004-36 FILL IN THE FLOODPLAIN
SP 2004-37 OUTDOOR DISPLAY IN AN ENTRANCE CORRIDOR
Request for Critical Slopes Waiver
Applicant's Proposal
Charlottesville Power Equipment is requesting to rezone 2.142 acres from C-1 (Commercial) to
HC (Highway Commercial) to allow a 12,000 square foot, two-story building for equipment
sales, offices, and limited repair and storage facilities. Behind the building, a yard area will be
used to store equipment waiting to be sold or repaired. A second smaller building will most
likely be built after the first building, and its use is undetermined at this time. The use is expected
to be either offices, a garden center, or other small, specialized retail. Tax Map 78, Parcel 4B
contains 1.871 acres and will be the location of the two buildings and storage yard. Tax Map 78,
Parcel 4A1 contains 0.271 acre and is the site of a slope easement essential for development of
the main parcel. (See Attachment A)
Access to the site will be from Rte 20 via an easement that intersects the driveway entering
McDonalds. Originally, the site had access from Free Bridge Lane. However, in prior legislative
acts, the County has restricted vehicular access for other properties to that street so that it can
become a paved trail within the greenway. Also, the topography of the site would make vehicular
access to Free Bridge Lane very difficult and costly.
This rezoning request is accompanied by applications for two special use permits to be
considered with the rezoning. These special use permit applications are for filling in the
floodplain and for outdoor storage and display in an entrance corridor. A request for a critical
slopes waiver has also been submitted with the application.
The application plan is Attachment B. The first special use permit would allow placement of fill
in the floodplain, in accordance with Section 30.3.05.2.2(3). The second special use permit
would allow outdoor storage and display in an entrance corridor, in accordance with Section
30.6.3.2(b) of the Zoning Ordinance. The property is located on the northwest corner of the
intersection of Rte 20 and 250, behind the McDonald's restaurant.
The applicant has submitted proffers (Attachment Q. The first proffer states that the
development on the site shall be "general accord" with the application plan, last revised on May
9, 2005, and that the limits of disturbance shown on the approved site plan shall not be
significantly different from the limits shown on the application plan. The second proffer limits
the number of uses allowed under the proposed rezoning to "machinery and equipment sales,
service, and rental" as allowed under the HC District. The third proffer addresses the form,
massing, character, and detailing shown in the proposed building elevations, dated December 28,
2004, and indicates that the buildings will be in conformity with those elevations and provides
for a process to resolve any conflicts in interpretation between the Architectural Review Board
and the Director of Planning. These elevations are included in Attachment D.
Petition
Request to rezone 2.142 acres from C-1 (Commercial) to HC (Highway Commercial) to allow
12,000 square feet of commercial use in two buildings with proffered plan. The proposal also
includes requests for outdoor sales and display and fill in the floodplain (see SP -04-36 and SP -
04 -37). The property, described as Tax Map 78, Parcels 4A1 and 413, is located in the Rivanna
Magisterial District on the northwest corner of the intersection of Route 20 and Route 250 East
behind McDonald's Restaurant. The Comprehensive Plan designates this property as Regional
Service, in Neighborhood Three.
Character of the Area
The properties subject to the application are located behind the McDonalds restaurant on the
northwest corner of the intersection of Routes 20 and 250. Uses surrounding this property
include two fast food restaurants, two gas stations, and a muffler repair facility. Free Bridge Lane
(Rt. 142 1) borders one side of this property. A greenway that is proposed for the area will
incorporate Free Bridge Lane as a paved trail and the area between Free Bridge Lane and the
Rivanna River.
RECOMMENDATION
Staff has reviewed the proposal for conformity with the Comprehensive Plan and the Zoning
Ordinance and recommends approval of the Zoning Map Amendment with proffers and special
use permits with conditions, if a critical slopes waiver is approved.
Planning and Zoning History
There have been no changes in the zoning classification of these two parcels since the County's
current Zoning Ordinance was adopted in 1980.
Planning Commission Input to Date
On November 16, 2004, staff presented Charlottesville Power Equipment to the Planning
Commission in a worksession. The applicant requested the worksession in response to staff's
comments on the first project submittal. In their comments, staff expressed concern about the
appropriateness of this use in this location, especially in close proximity to the Rivanna River
and proposed greenway. Staff raised several questions for the Commission to consider and to
provide guidance to staff
2
1. Is the proposed use appropriate at this location? Does the Planning Commission find that
this site should contain a use that is oriented towards the Greenbelt and River?
The Planning Commission noted that it was not really so much whether this use is
appropriate or not, but it is more about how the buildings are oriented based on the
topography.
In response to the Planning Commission's concern, the applicant has changed the
orientation of the building toward the greenwayt and the river. The applicant has also
added landscaped paths and a small resting area with a bench seat to facilitate access
from the site to the greenway.
2. Does the Planning Commission believe that the request for "Outdoor Storage and
Display" is appropriate at this site, given its location near the Route 250 Entrance
Corridor and the Rivanna Greenway?
It was the consensus of the Commission that the proposed use would be appropriate at
this location, depending on the design.
One commissioner stated that the Commission's perspective may be different from the
ARB's because their point of view is the Entrance Corridor and the Commission's may
be from the river and other places.
The applicant has screened the storage lot from both the river/greenway and the entrance
corridor. This addresses both the Planning Commission's and the ARB's perspectives.
3. Does the Planning Commission believe that the request for "Fill in the Floodplain" at this
site is appropriate to support a development such as the one proposed?
It was the consensus of the Planning Commission that the design should be more
responsive to the floodplain. The Commission did not have the engineering information
to know how much area will be filled, but they indicated that the applicant should be very
cautious about filling in the floodplain.
One commissioner asked if the Commission felt that the request for fill in the floodplain
at this site is appropriate to support the development that is being proposed. The basic
question is whether this is the proper use for the infill in the floodplain.
The Planning Commission asked staff to look at the new FEMA maps, which will be in
effect in February, to determine the fringe and buffer area towards the floodplain.
It should be demonstrated that the amount of fill is absolutely minimized, and whatever
redesign is done to make the project a more sympathetic fit must take into account that
fill in the floodplain should be minimized.
Concern was expressed that it appeared the critical slope was caused by the previous
development on the McDonald's site. The larger building in this proposal is right in the
middle of the critical slopes on the site. The Commission was not opposed to the use, but
would like to see a redesign that might be more respectful of the critical slopes than what
the current proposal shows.
In general consensus, the Planning Commission agreed that utilizing buildings to take up
critical slopes is often a very sensible thing to do.
The applicant has revised his earlier proposal to be more responsive to the floodplain;
the stormwater management facility has been removed from the floodplain and the
amount of fill shown is small. The applicant has designed the buildings on the site to take
advantage of one area of critical slopes; the front of the building is one story in height
and the side facing the river is two stories in height. The other area of critical slopes is
being incorporated into the driveway access.
Applicant's Justification for the Request
The applicant has made the following key points: their plan responds to the requirements of the
Neighborhood Model and will enable a good use of a difficult site.
The site represents a difficult infill challenge. It is zoned C-1, a district that allows retail, eating
establishments, or other service uses by right. However, the applicant's market research indicates
that the site's poor visibility (it is situated behind two gas stations, two fast food restaurants, and
a muffler repair facility) makes it unlikely to support these uses because they rely on highway
traffic from nearby roads. Secondly, the site slopes steeply down to the Rivanna River and
floodplain covers a large percentage of the site. This results in a limited amount of developable
land. Therefore, the applicant has chosen to proceed with specialized retail or office uses that
will be a specific destination for shoppers. Since machinery and equipment sales and service are
only allowed in an HC District, the applicant has decided to request rezoning of the property.
The applicant has submitted a proffer stipulating that only the "machinery and equipment sales,
service and rental" use permitted under the HC district would be applicable to the property, in
addition to all C- I uses.
Access to the parcel is via an easement adjacent to the driveway into the McDonalds. The
restaurant and the proposed equipment sales uses will share the entrance to their respective
driveways.
By -right Use of the Property
With a C-1 zoning classification, the property could be developed with selected retail sales,
service and public use establishments.
Comprehensive Plan and The Neighborhood Model
Chapter 2 of the Comprehensive Plan, entitled "Natural Resources and Cultural Assets," sets
goals for preserving those scenic resources that are recognized as essential to the County's
character, economic vitality, and quality of life. The Entrance Corridor Overlay Districts were
established to meet the Comprehensive Plan objective of maintaining the visual integrity of
important roadways. The Architectural Review Board (ARB) addresses the aesthetic impacts of
development on those roads by applying the County's design standards for development within
Entrance Corridors. The ARB has reviewed the applicant's conceptual site layout and building
design for conformity with the County's adopted design guidelines and recommends approval of
the conceptual plan with conditions (Attachment E).
Requests for a zoning map amendment within the Development Areas are assessed for
conformity with the Neighborhood Model (NMD) and the Land Use Plan.
The Land Use Plan shows this area as Regional Service:
Uses allowed include regional -scale commercial, regional malls, medical centers, mixed-use
developments, hotel/motel/conference facilities, professional and corporate offices, interstate
interchange developments and uses providing retail, wholesale, business, and/or employment
services to Albemarle County and the region.
Areas designated as Regional Service typically encompass a large site (+30 acres), arterial
road accessibility, water and sewer availability, and compatibility with adjacent land uses.
Both vehicular and pedestrian interconnections are expected to nearby residential areas.
A mixture of Urban Density Residential uses and community service uses is anticipated
within this designation.
The Pantops (Neighborhood Three) Development Area profile includes the following
recommendations:
Construct a greenway along the South Fork of the Rivanna River and the Rivanna River. This
provides a pedestrian connection of the Ivy Creek Natural Area to the Urban Area and an
opportunity for passive recreation adjacent to the Urban Area. Develop the greenway to meet
the recreational and conservation needs of the residents in the Neighborhood, and the entire
County.
The proposed development includes a pedestrian path linking the site to the proposed greenway.
PRINCIPLES OF THE NEIGHBORHOOD MODEL
Principle
How Principle Is Addressed in This Application
Pedestrian
The concept plan offers a pedestrian circulation network within the site,
Orientation
between parking areas and the two buildings. There are also paths
connecting the building site with Free Bridge Lane and the proposed
greenway. A sidewalk is proposed to connect the site with the existing
sidewalk along Route 20.
5
Neighborhood
The concept plan shows paths connecting the site with Free Bridge
Friendly Streets
Lane and, eventually, with the greenway. Landscaping will be provided
and Paths
around the site to improve views to/from the site and make the paths
more attractive.
Interconnected
This development is so small that the only realistic interconnection is
Streets and
the paths between the site and Free Bridge Lane/proposed greenway.
Transportation
Networks
Parks and Open
Much of the site will be preserved as floodplain. The paths mentioned
Space
above will be part of this area. Some landscaping is provided.
Neighborhood
This development is being added to a cluster of existing fast food
Centers
restaurants, gas stations, and car repair shops. As such, it is filling in a
complementary use.
Buildings and
The two-story building is human scale and the site is designed for
Spaces of Human
human activity, especially the walking paths.
Scale
The ARB has reviewed this plan and generally supports it.
Relegated
The plan provides parking in front of the main building, which screens
Parking
the parking from Free Bridge Lane and the river. This means that the
parking respects the orientation of the building toward the river. The
parking in front of the main building is also screened from the Entrance
Corridor by the McDonalds. The objective of relegated parking is to
screen it from view as much as possible. Because this site is located
behind uses that front on Rte. 20 and 250, putting the parking in front
of the building is a good response to the objective of relegated parking.
Mixture of Uses
This is a very small site on which there is the potential for a limited
number of uses (commercial, retail, office), so this principle is not met.
Mixture of
This is a commercial property, so the provision of housing would not
Housing Types
be anticipated on such a small site. This principle is not met.
and Affordability
Redevelopment
This is a greenfield development, so this principle does not apply.
Site Planning that
This is a difficult infill site. The amount of floodplain, the existence of
Respects Terrain
steep slopes, and the difficult access constrain development of this site.
Grading will result in some 2:1 slopes that will need to be stabilized
with vegetation. The applicant has applied for a critical slopes waiver,
noting in his application that some, if not all, of the critical slopes are
manmade.
Cross section B on the application plan shows that the building has
been designed to take advantage of the grade change.
The applicant has moved the stormwater management facilities out of
the floodplain.
The applicant will need to place a small amount of fill in the floodplain
to accommodate the access road.
This application allows for construction of two buildings, along with
sufficient parking for both, as proposed. The applicant has been
notified that any change in the proposed use of the second, smaller
building may result in insufficient parking.
ZMA 2004-11– Rezoning from C-1 to HC (Highway Commercial)
STAFF COMMENT
Relationship between the application and the purpose and intent of the requested zoning
district
The site is currently zoned C-1 (Commercial). C-1 districts permit selected retail sales, service
and public use establishments. These districts are intended to be established only within the
urban area, communities, and villages as set out in the Comprehensive Plan. The by -right uses
permitted in C-1 districts are those that require a certain level of visibility from a highway in
order to attract sufficient customers.
HC (Highway Commercial) districts permit development of commercial establishments, other
than shopping centers, primarily oriented to highway locations rather than to central business
concentrations (e.g., downtown areas). It is intended that HC districts be established on major
highways within the urban area and communities in the comprehensive plan. The by -right uses
permitted in HC districts are those that require proximity to a highway for access, but do not
necessarily require visibility to attract customers. These businesses are destinations that
customers plan to patronize, rather than ones they may select "on impulse" as they drive by.
The site does not front directly on either Rte 20 or 250; Tuffy Muffler, Wilco, Wendy's, and
McDonalds are all between the site and Rte 20 and 250. Thus, the site has little visibility from
either highway. The applicant's market research indicated that the uses permitted under the
current C-1 zoning would not be financially feasible due to this lack of visibility. Instead, the
applicant is proposing a use—machinery and equipment sales, service and rental—that is more
likely to be successful on the site. This use is a highway -oriented destination, the type permitted
in HC districts. However, many of the other uses permitted in an HC district would not be
appropriate in this location. So, the applicant has requested rezoning to an HC district, but has
proffered that the only HC use permitted will be machinery and equipment sales, service and
rental, along with all C-1 uses.
Public need and justification for the chance
Staff believes that rezoning this property from C-1 (Commercial) to HC (Highway Commercial)
will make the property more developable.
7
The fill in the floodplain and the use of two retaining walls indicate that
the applicant is pushing the limits of what may be built on this site. The
proposal shows more respect for the terrain than earlier ones did, but
less development on the site might mean less fill in the floodplain.
Clear Boundaries
This project is well within the Development Area, so this principle does
with the Rural
not apply.
Areas
ZMA 2004-11– Rezoning from C-1 to HC (Highway Commercial)
STAFF COMMENT
Relationship between the application and the purpose and intent of the requested zoning
district
The site is currently zoned C-1 (Commercial). C-1 districts permit selected retail sales, service
and public use establishments. These districts are intended to be established only within the
urban area, communities, and villages as set out in the Comprehensive Plan. The by -right uses
permitted in C-1 districts are those that require a certain level of visibility from a highway in
order to attract sufficient customers.
HC (Highway Commercial) districts permit development of commercial establishments, other
than shopping centers, primarily oriented to highway locations rather than to central business
concentrations (e.g., downtown areas). It is intended that HC districts be established on major
highways within the urban area and communities in the comprehensive plan. The by -right uses
permitted in HC districts are those that require proximity to a highway for access, but do not
necessarily require visibility to attract customers. These businesses are destinations that
customers plan to patronize, rather than ones they may select "on impulse" as they drive by.
The site does not front directly on either Rte 20 or 250; Tuffy Muffler, Wilco, Wendy's, and
McDonalds are all between the site and Rte 20 and 250. Thus, the site has little visibility from
either highway. The applicant's market research indicated that the uses permitted under the
current C-1 zoning would not be financially feasible due to this lack of visibility. Instead, the
applicant is proposing a use—machinery and equipment sales, service and rental—that is more
likely to be successful on the site. This use is a highway -oriented destination, the type permitted
in HC districts. However, many of the other uses permitted in an HC district would not be
appropriate in this location. So, the applicant has requested rezoning to an HC district, but has
proffered that the only HC use permitted will be machinery and equipment sales, service and
rental, along with all C-1 uses.
Public need and justification for the chance
Staff believes that rezoning this property from C-1 (Commercial) to HC (Highway Commercial)
will make the property more developable.
7
Anticipated impact on public facilities and services
The proposed rezoning will have an increased impact on stormwater management because the
property will be developed. Under the current zoning, it is unlikely the property would be
developed due to the lack of visibility from the nearby highways. Stormwater management will
conform to County ordinances.
No adverse impacts are expected on streets, water, and sewer.
Anticipated impact on natural, cultural, and historic resources
No impact is anticipated on cultural or historical resources of the County. The pedestrian path
tie-in to the proposed greenway will be a benefit for the County. Eliminating the access to Free
Bridge Lane will simplify the greenway planning process.
SUMMARY
Staff has identified the following factors that are favorable to the rezoning request:
1. The rezoning will enable development of a difficult infill site, which might not otherwise
be developed.
2. The applicant has offered a plan for development that incorporates several of the
principles of the Neighborhood Model.
3. The site will feature a pedestrian connection to the adjacent greenway.
4. The applicant has agreed not to access the site from Free Bridge Lane; instead access will
be provided via an easement on the adjacent McDonalds site. The applicant's decision to
provide alternative access supports the County's intention to convert Free Bridge Lane to
a paved pedestrian path within the proposed greenway.
Staff has identified no factors that are unfavorable to this request.
RECOMMENDED ACTION
Staff recommends approval of the rezoning with the attached proffers.
SP 2005-36 FILL IN THE FLOODPLAIN
Applicant's Proposal
The applicant proposes to place a small amount of fill in the floodplain, outside of the stream
buffer, to accommodate grading necessary for the buildings and parking areas. Placing the fill
will create some 2:1 slopes and require retaining walls in two locations.
N.
Petition
Request for a special use permit to allow fill in the floodplain in accordance with Section
30.3.05.2.2(3) of the Zoning Ordinance which allows for filling of land. See concurrent requests,
ZMA-04-11 and SP -04-37. The property, described as Tax Map 78, Parcels 4A1 and 413, is
located in the Rivanna Magisterial District on the northwest corner of the intersection of Route
20 and Route 250 East behind McDonald's Restaurant. The Comprehensive Plan designates this
property as Regional Service, in Neighborhood Three.
STAFF COMMENT
Staff has reviewed the request for a special use permit for fill in the floodplain. From the
information on the concept plan and in the application, the property is in an area of detailed study
on FIRM 287, and as such will require the use of the FEMA model or its equivalent.
The fill in the floodplain and on slopes off the travelway are small in comparison to the width of
the floodplain and the river in this area. Therefore, staff does not believe that the fill will have a
significant impact on the flood -carrying capacity of the river. However, because this is a detailed
study area for FEMA that was recently updated, staff would like to keep the study area maps up-
to-date. Requiring the applicant to obtain a letter of map revision also keeps FEMA informed in
case they should have a concern with the fill.
RECOMMENDED ACTION
Staff recommends approval of SP -2004-36, subject to the following conditions:
1. A letter of map amendment must be obtained from FEMA.
2. Copies of state and federal permits (DEQ, Army Corps of Engineers) must be provided.
SP 2004-37 OUTDOOR STORAGE AND DISPLAY IN AN ENTRANCE CORRIDOR
Applicant's Proposal
The applicant proposes to store and display equipment outside the building in the locations
indicated on the plan shown in Appendix F. Some of the for -sale equipment will be displayed
outside the building or under the tower, and some of the equipment waiting for repair will be
stored outside in the lot at the rear of the building.
Petition
Request for a special use permit to allow outdoor sales and display associated with permitted
uses, which would be visible from an Entrance Corridor Street in accordance with Section
30.6.3.2(b) of the Zoning Ordinance. See concurrent requests, ZMA-04-11 and SP -04-36. The
property, described as Tax Map 78, Parcels 4A1 and 413, is located in the Rivanna Magisterial
District on the northwest corner of the intersection of Route 20 and Route 250 East behind
0
McDonald's Restaurant. The Comprehensive Plan designates this property as Regional Service,
in Neighborhood Three.
RECOMMENDATION
Staff has reviewed this request for compliance with the provisions of the Comprehensive Plan
and Zoning Ordinance Sections 31.2.4.1 and 30.6.3.2.b, and recommends approval of SP 2004-
37, with conditions.
Architectural Review Board (ARB)
The ARB reviewed this proposal at its meeting on February 22, 2005. The ARB had no objection
to the request for the rezoning. The ARB has no objection to the request for the Special Use
Permit, with conditions. The ARB's comments are in Attachment E.
STAFF COMMENT
Staff will address each provision of Section 31.2.4.1 of the Zoning Ordinance.
The Board of Supervisors hereby reserves unto itself the right to issue all special use permits
permitted hereunder. Special use permits for uses as provided in this ordinance may be issued
upon a finding by the Board of Supervisors that such use will not be of substantial detriment to
adjacent property,
It is anticipated that the storage and display of lawn care and similar equipment will not have a
negative impact on the surrounding uses or on the site itself. The conditions proposed by the
ARB will prevent the equipment from being visible to drivers and pedestrians in the Entrance
Corridor.
that the character of the district will not be changed thereby
It is anticipated that the proposed use will not change the character of the EC district for the
following reasons:
The site is surrounded by other commercial uses.
The display area is limited in size and will be screened by the building.
Recommended additional landscaping will help limit visibility of the display from the road.
The potential impact of the use on the character of the district has been addressed by the ARB.
The ARB has recommended conditions of approval.
and that such use will be in harmony with the purpose and intent of this ordinance,
Staff has reviewed this request for compliance with the purpose and intent of the Zoning
Ordinance, as stated in Section 1.4, and identified no conflict that would arise as a result of its
approval.
10
with the uses permitted by right in the district,
The proposed display use will not have an impact on permitted uses in the EC District.
with additional regulations provided in Section 5.0 of this ordinance,
There are no additional regulations in Section 5.0 specifically addressing the display of
equipment.
and with the public health, safety and general welfare.
No adverse impacts on the public health, safety, and/or welfare are anticipated.
RECOMMENDED ACTION
Staff recommends approval of SP 2004-37, subject to the following conditions:
1. Site lighting shall be limited, to the satisfaction of the ARB.
2. The storage yard fence shall be of material, character, and design that are coordinated with
the building, to the satisfaction of the ARB.
3. Regarding items for storage/display:
a. Equipment shall be stored/displayed only in areas indicated for storage/display on the
"Display Area Exhibit" plan dated June 14, 2005.
b. Items located in the storage lot on the north side of the building shall not exceed 10
feet in height. The height may be varied depending on other corresponding site and/or
grading changes, as determined by the ARB.
c. Items located in the display areas under the two easternmost awnings on the south side
of the building shall be limited to small lawn mowers, rototillers, and other similarly
sized items. Items shall not extend into sidewalk, landscape, or parking areas.
d. Items located under the tower shall be fully contained within the structure of the
roofed tower, as shown on the architectural elevation drawing sheet A3 (East/front
Elevation) and A5 (South Elevation), dated May 9, 2005.
e. Equipment shall not be elevated anywhere on the site.
4. Additional landscaping beyond that shown on the Conceptual Landscape Plan with revision
date of May 9, 2005, is required. Landscaping, including but not limited to, evergreen plants
on the north side of the entrance road to further limit visibility of the storage lot, shall be
provided to the satisfaction of the ARB. An agreement regarding the location, placement, and
maintenance of this additional landscaping must be signed by the property owner and
approved by the ARB prior to the approval of any site plan.
Request for Critical Slopes Waiver
The applicant has requested a Critical Slopes Waiver. Staff has reviewed the request for a
Critical Slopes Waiver. The engineering analysis of the request follows:
11
Description of critical slope area and proposed disturbance
The areas of critical slope are along the natural hillside between McDonald's and Free Bridge
Lane, and in a former stockpile area behind the Wilco site. There is also a disturbance of man-
made critical slopes along the entrance, which is off-site, on the embankment created by the
McDonalds adjacent to Route 20, above their existing stormwater basin. After temporary
disturbance for erosion control measures, it is expected that most of the critical slopes on the site
will be disturbed.
Areas
Acres
Total site
2.139 (tm.78-413 & 78-4A1)
Critical slopes
0.46
22% of site
Critical slopes disturbed
0.39
85% of critical slopes
* the area of off-site critical slope disturbance for the entrance is an additional 0.10 acres.
Exemptions to critical slopes waivers for driveways, roads and utilities without reasonable
alternative locations
The off-site disturbance and a small corner of the on-site disturbance are necessary to create the
entrance and travelway to the site.
Compliance with Zoning Ordinance 18-4.2
Staff will address each provision of Section 4.2 of the Zoning Ordinance.
These provisions are created to implement the comprehensive Dlan by Drotectinc and conservin
steep hillsides together with public drinking water suflplies and floodplain areas and in
recognition of increased potential for soil erosion, sedimentation, water pollution and septic
disposal problems associated with the development of those areas described in the
comprehensive plan as critical slopes. It is hereby recognized that such development of critical
slopes may result in: rapid and/or large-scale movement of soil and rock;
Proper slope and wall construction, control of drainage, and vegetative stabilization will
prevent any movement of soil.
excessive storrawater runoff
Stormwater runoff will be increased by impervious areas and steeper slopes being placed on
the site. A waiver has been requested for detention, and will likely be granted with the site
plan review according to 17-314176, provided adequate channels are satisfactorily addressed
through off-site improvements. It has been recommended with the rezoning that some benefit
could be provided by improving the existing basin for the McDonald's site, but so far the
applicant has declined to pursue this.
siltation of natural and man-made bodies of water;
Inspection and bonding by the County will ensure siltation control on-site during
12
construction. Proper stabilization and maintenance will ensure long term stability, on-site.
The off-site disturbance will likely cause siltation in the McDonalds basin, which lies directly
below the disturbance and a proposed retaining wall.
loss of aesthetic resource;
This area is visible from the greenway trail and Free Bridge Lane, and has a limited view
from Route 20. It has been recently cleared of small trees and brush in some areas. There is
trash and debris on the site.
The Comprehensive Plan Greenway Plan Trail Locations Map shows this greenway trail as a
"Class A" trail. Class A trails are to be eight feet wide, either paved or compacted crushed
stone, and ADA and bicycle accessible. Thus, this section of the greenway is expected to
receive significant use.
and in the event of septic system failure, a greater travel distance of septic effluent, all of which
constitute potential dangers to the public health, safety and/or welfare.
This is not a concern, as the site will be serviced by public sewer.
Based on the review above, it is recommended that the applicant work out an arrangement with
the McDonald's site to refurbish the existing basin after its expected siltation during construction.
RECOMMENDED ACTION
Staff recommends that the request for a critical slopes waiver be granted.
ATTACHMENTS
Attachment A
— Location Map
Attachment B
— Application Plan (4 sheets)
Attachment C
— Proffers
Attachment D
— Proposed Building Elevations
Attachment E —
ARB Letter
Attachment F —
Display Areas Map
13