Loading...
HomeMy WebLinkAboutSDP202000049 Review Comments Final Site Plan and Comps. 2020-08-03SDP202000049 - Mill Creek Industrial Lot 11— Final Engineering comments (David James): 1. Submit a VSMP application & plan if you haven't already. Disturbance over 10,000sf.117-3021 2. It appears that the parcel boundary line appears different than what's shown in County GIS, and will need to confirm with real estate if property line shown is accurate. 3. Show areas of off -site disturbance in an easement (i.e. entrance improvements). Signed letter of permission from an offsite owner is sufficient, but only for the purposes of this review, or record a plat. 4. Submit design plans & comps for walls over 4' high prior to FSP approval. 5. Cover — a. Sign & date seal. b. The stated sheet layout of 1" = 30' do not appear to be accurate. 6. Sheet 3 — a. Remove curb before CG-12 and show access apron. b. Show safety railing for walls over 30" high. 7. Sheet 4 — Provide reverse slope bench and/or surface water diversion for the graded slopes. 118- 30.7.5} PROPOSED WALL MAX. HEIGHT=io' 458.50TC SS.00EP 75&58TC P�463TW 4598W 24"LET 4.50 1.50 ' ) STONE LINED TRAPReQAL NNEL OUTFALL (16" WIDE Af—' 48 M, 6'DEEP, 2:1 SIDE SLOPES) �//-� Nto tr b tr 6 8. Sheet 5 — a. Show ground cover (not grass) for disturbed slopes over 3:1 grade. b. Remove proposed trees and place trees outside of public drainage easements. 9. Sheet 8—Storm STR 4 to 2 the line is 12" dia. and will need an additional MH access (over 50' length) [VDOT DM 9.3.6, table 9.31, or use a 15" dia.