Loading...
HomeMy WebLinkAboutSP202000004 Plan - Approved 2020-08-05 811 .i,;. z ri +i= TOTALLY COMMITTER Know what's below. z verizonxi Call before you dig. L`J PIING ENGINEERING SERVICES,LLC. 804.5.4070 Community Development Department _ File# 9911074, -ODtO N SITE INFORMATION Approved by the Board of Supervisors • 7 verizon✓ PROJECT DESCRIPTION- RAWLAND:PROPOSED INSTALLATION OF SITE NAME: WILD TURKEY Date . �) D- 0..A. 1831 RADY COURT TELECOMMUNICATIONSQUIPMETWTHINSECUREDCAMP UND. , ITOWERANDRELD. RICHMOND,VA23222 SITE ADDRESS. WILD TURKEY LANE WILD TURKEY LANE CHARLOTTESVILLE,VA 22903 CHARLOTTESVILLE, VA 22903 S !n fro - Plan r — LATITUDE LONGITUDE NNAD83): 8 3953.70307" ALBEMARLE COUNTY z 0 GROUND ELEVATION: 667.3't(ASML) DRAWING INDEX § WILD TURKEY ii WILD TURKEY LANE JURISDICTION: ALBEMARLE COUNTY VICINITY o CHARLOTTESVILLE,VA 22903 SCALE:1"=2000' T-1 TITLE SHEET Z ZONING: RA-RURAL AREA ALBEMARLE COUNTY EE-1 EASEMENT EXHIBIT PARCEL ID#: 05700-00-00-041L0 . ..._" ._ . EE-2 EASEMENT EXHIBIT PARCEL AREA: 6.0±ACRES Z-1 2,000 TOPO BOUNDARY PARCEL OWNER. ROBERT L&JEANNE K CROSS TRUSTEES OF THE '' REVISIONS CROSS LIVING TRUST �Q; C-1 SITE PLAN 635 BOONE TRAIL 04' C-2 ENLARGED SITE PLAN CHARLOTTESVILLE,VA 22903 y w 0 8 0811020 REVISED CT TOWER OWNER: VERIZON C-3 COMPOUND PLAN 0 1831 RADY COURT w0 5 oorzorzo REVISED CCC RICHMOND,VA23222 C-4 TREE INVENTORY 0= 4 03/0920 REVISED PJP 1.1423tim' C-5 TOWER ELEVATION DETAILS&NOTES CD 3 02/2420 REVISED PJP STRUCTURE TYPE. MONOPOLE w 2 12/0429 REVISED CCC C5 MOUNT DETAILS O HEIGHT OF STRUCTURE: 116.7't AGL srt[ PIMP 1 11/18H8 FINALS CCC SITE S-1 EQUIPMENT MOUNTING DETAILS Ir 0 10/3029 PRELIMINARY CD WS RAD CENTER: 112.7'±AGL S-2 CONCRETE PAD DETAILS =t REV DATE DESCRIPTION BY OVERALL HEIGHT OF STRUCTURE: 118.7'±AGL - S-3 CONSTRUCTION DETAILS&NOTES TOTAL LEASE AREA: 900 SQ.FT. S-4 CONSTRUCTION DETAILS AREA OF DISTURBANCE: 3,335±SQ.FT. S5 GENERATOR DETAILS EL POWER PROVIDER: DOMINION VA POWER 866 366-0357 ?4''4`1 H Op y ( ) E-1 ELECTRICAL PLAN TELCO PROVIDER: VERIZON(800)871-9244 Q o E-2 CONDUIT ROUTING PLAN Q `. ��h ypL Z-1 TOPOGRAPHY: ALBEMARLE COUNTY GIS 2018,4'CONTOURS z E-3 PANEL SCHEDULE 8 ONE-LINE DIAGRAM 0 JOHN No. z1 DAUGHTREY III P L��O6/102020 ES-1 TOPOGRAPHY' CAUSEWAY CONSULTANT'S SURVEY DATED 09/30/19 DIRECTIONS E-4 ELECTRICAL RISER DIAGRAM&SERVICE ENTRANCE SCHEMATIC LL 0.66 \''' 0 EMERGENCY INFORMATION: DEPART GOODES BRIDGE RD TOWARD WALMSLEY BLVD.TURN RIGHT ONTO WALMSLEY BLVD.TURN RIGHT ONTO G-1 GROUNDING PLAN AND DETAILS cc ss/ONAL ECG TURNER RD.TURN RIGHT ONTO US-360 E/HULL ST RD.TAKE RAMP RIGHT FOR VA-150 NORTH TOWARD POWHITE PKWY. TAKE RAMP RIGHT AND FOLLOW SIGNS FOR VA-76-TOLL NORTH.ROAD RESTRICTED AT YOUR PLANNED TRAVEL TIME. G-2 GROUNDING RISER DIAGRAM&DETAILS ALBEMARLE COUNTY FIRE&RESCUE: (434)296-5833 KEEP LEFT TO STAY ON VA-76 N/BELTLINE EXPY.KEEP STRAIGHT ONTO 1-195 N.TAKE RAMP LEFT FOR 1-64 WEST ES-1 EROSION AND SEDIMENT CONTROL&GRADING PLAN �. . TOWARD CHARLOTTESVILLE.AT EXIT 114,TAKE RAMP RIGHT TOWARD IVY.TURN RIGHT ONTO VA-637/DICK WOODS RD. ALBEMARLE COUNTY SHERIFFS OFFICE: (434)972-4001 MAKE A U-TURN AT IVY DEPOT RD.TURN LEFT ONTO US-250/IVY RD.KEEP LEFT TO STAY ON US-250.TURN LEFT ONTO ES-2 EROSION AND SEDIMENT CONTROL NOTES WILD TURKEY LN.ARRIVE AT SITE ON THE LEFT. cc ES-3 EROSION AND SEDIMENT DETAILS Lu J JOHN A.DAUGHTREY III,P.E. PROJECT TEAM CODE COMPLIANCE ES-4 EROSION AND SEDIMENT CONTROL DETAILS I VA PROFESSIONAL ENGINEER LIC.#052122 ES-5 EROSION AND SEDIMENT CONTROL DETAILS II CONSTRUCTION MANAGER NETWORK BUILDING&CONSULTING ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF JOHN KIRBY THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.NOTHING IN THESE PLANS IS TO BE DO NOT SCALE DRAWINGS (540)280-9630 CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. • 2015 INTERNATIONAL BUILDING CODE • ANSI/TIA-222-G THESE DRAWINGS ARE FORMATTED TO BE FULL-SIZE AT 24"X36".CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND PROJECT MANAGEMENT FIRM: GDN SITES • 2014 NATIONAL ELECTRICAL CODE • TIA 607 SHALL IMMEDIATELY NOTIFY THE DESIGNER/ENGINEER IN WRITING OF ANY TITLE SHEET NATE HOLLAND DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE _ (757)305-8420 • 2015 NFPA 101,LIFE SAFETY CODE • INSTITUTE FOR ELECTRICAL&ELECTRONICS ENGINEER 81 RESPONSIBLE FOR THE SAME.CONTRACTOR SHALL USE BEST MANAGEMENT PRACTICE cn • 2015 IFC IEEE C2 NATIONAL ELECTRIC SAFETY CODE LATEST EDITION TO PREVENT STORM WATER POLLUTION DURING CONSTRUCTION. ENGINEERING FIRM- NB+C ENGINEERING SERVICES,LLC. 4435 WATERFRONT DRIVE • AMERICAN CONCRETE INSTITUTE TELECORDIA GR-1275 SUITE 100 GLEN ALLEN,VA 23060 AMERICAN INSTITUTE OF STEEL CONSTRUCTION • ANSI/T 311 m (804)548-4079 Z T-1 • MANUAL OF STEEL CONSTRUCTION 14TH EDITION � LL TIN SITE INFORMATION PROJECT DESCRIPTION: RAWLAND: PROPOSED INSTALLATION OF TELECOMMUNICATIONS TOWER AND RELATED EQUIPMENT WITHIN SECURED COMPOUND. SITE ADDRESS: WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 LATITUDE (NAD 83): 380 3' 14.0503" LONGITUDE (NAD 83): -780 39' 53.7307" GROUND ELEVATION: 667.3' ± (ASML) JURISDICTION: ALBEMARLE COUNTY ZONING: RA - RURAL AREA PARCEL ID #: 05700-00-00-041 LO PARCEL AREA: 6.0 ± ACRES PARCEL OWNER: ROBERT L & JEANNE K CROSS TRUSTEES OF THE CROSS LIVING TRUST 635 BOONE TRAIL CHARLOTTESVILLE, VA 22903 TOWER OWNER: VERIZON 1831 RADY COURT RICHMOND. VA 23222 STRUCTURE TYPE: MONOPOLE HEIGHT OF STRUCTURE: 116.7'±AGL RAD CENTER: 112.7'± AGL OVERALL HEIGHT OF STRUCTURE: 118.7'± AGL TOTAL LEASE AREA: 900 SQ. FT. AREA OF DISTURBANCE: 3,335 ± SQ. FT. POWER PROVIDER: DOMINION VA POWER (866)366-4357 TELCO PROVIDER: VERIZON (800)871-9244 Z-1 TOPOGRAPHY: ALBEMARLE COUNTY GIS 2018, 4' CONTOURS ES-1 TOPOGRAPHY: CAUSEWAY CONSULTANT'S SURVEY DATED 09/30/19 EMERGENCY INFORMATION: ALBEMARLE COUNTY FIRE & RESCUE: (434) 296-5833 ALBEMARLE COUNTY SHERIFF'S OFFICE: (434) 972-4001 PROJECT TEAM CONSTRUCTION MANAGER: NETWORK BUILDING & CONSULTING JOHN KIRBY (540) 280-9630 PROJECT MANAGEMENT FIRM: GDN SITES NATE HOLLAND (757) 305-8420 ENGINEERING FIRM: NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE SUITE 100 GLEN ALLEN, VA 23060 (804) 548-4079 m SITE NAME: WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY VICINITY MAP SCALE: 1" = 2000' GaQSQµe I'ai. Nill (Q,01' Mechums River SITE SITE 0 z LJ 3iJ DIRECTIONS DEPART GOODIES BRIDGE RD TOWARD WALMSLEY BLVD. TURN RIGHT ONTO WALMSLEY BLVD. TURN RIGHT ONTO TURNER RD. TURN RIGHT ONTO US-360 E / HULL ST RD. TAKE RAMP RIGHT FOR VA-150 NORTH TOWARD POWHITE PKWY. TAKE RAMP RIGHT AND FOLLOW SIGNS FOR VA-76-TOLL NORTH. ROAD RESTRICTED AT YOUR PLANNED TRAVEL TIME. KEEP LEFT TO STAY ON VA-76 N / BELTLINE EXPY. KEEP STRAIGHT ONTO 1-195 N. TAKE RAMP LEFT FOR 1-64 WEST TOWARD CHARLOTTESVILLE. AT EXIT 114, TAKE RAMP RIGHT TOWARD IVY. TURN RIGHT ONTO VA-637 / DICK WOODS RD. MAKE A U-TURN AT IVY DEPOT RD. TURN LEFT ONTO US-250 / IVY RD. KEEP LEFT TO STAY ON US-250. TURN LEFT ONTO WILD TURKEY LN. ARRIVE AT SITE ON THE LEFT. CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING CODES. • 2015 INTERNATIONAL BUILDING CODE • ANSI/TIA-222-G • 2014 NATIONAL ELECTRICAL CODE • TIA 607 • 2015 NFPA 101, LIFE SAFETY CODE • INSTITUTE FOR ELECTRICAL & ELECTRONICS ENGINEER 81 • 2015 IFC • IEEE C2 NATIONAL ELECTRIC SAFETY CODE LATEST EDITION • AMERICAN CONCRETE INSTITUTE • TELECORDIA GR-1275 • AMERICAN INSTITUTE OF STEEL CONSTRUCTION • ANSI/T 311 • MANUAL OF STEEL CONSTRUCTION 14TH EDITION Know what's below. Call before you dig. DRAWING INDEX T-1 TITLE SHEET EE-1 EASEMENT EXHIBIT EE-2 EASEMENT EXHIBIT Z-1 2,000 TOPO BOUNDARY C-1 SITE PLAN C-2 ENLARGED SITE PLAN C-3 COMPOUND PLAN C-4 TREE INVENTORY C-5 TOWER ELEVATION DETAILS & NOTES C-6 MOUNT DETAILS S-1 EQUIPMENT MOUNTING DETAILS S-2 CONCRETE PAD DETAILS S-3 CONSTRUCTION DETAILS & NOTES S-4 CONSTRUCTION DETAILS S-5 GENERATOR DETAILS E-1 ELECTRICAL PLAN E-2 CONDUIT ROUTING PLAN E-3 PANEL SCHEDULE & ONE -LINE DIAGRAM E-4 ELECTRICAL RISER DIAGRAM & SERVICE ENTRANCE SCHEMATIC G-1 GROUNDING PLAN AND DETAILS G-2 GROUNDING RISER DIAGRAM & DETAILS ES-1 EROSION AND SEDIMENT CONTROL & GRADING PLAN ES-2 EROSION AND SEDIMENT CONTROL NOTES ES-3 EROSION AND SEDIMENT DETAILS ES-4 EROSION AND SEDIMENT CONTROL DETAILS I ES-5 EROSION AND SEDIMENT CONTROL DETAILS II DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED TO BE FULL-SIZE AT 24"X36". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE DESIGNER / ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR MATERIAL ORDERS OR BE RESPONSIBLE FOR THE SAME. CONTRACTOR SHALL USE BEST MANAGEMENT PRACTICE TO PREVENT STORM WATER POLLUTION DURING CONSTRUCTION. m LU LU TOTALLY COMMITTED z LU NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 Verizom/ Q 1831 RADY COURT RICHMOND, VA 23222 NJ Q I I WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 w ALBEMARLE COUNTY 11 REVISIONS 6 06/10/20 REVISED CT 0 m O 5 04/20/20 REVISED CCC U LU m 4 03/09/20 REVISED PJP Z 03 02/24/20 REVISED PJP U) LU 2 12/04/19 REVISED CCC m LU LU z_ z LU LU J w LU 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US REV DATE DESCRIPTION BY ��E�yTH OF lst% U Ax Y JOHN A. DAUGHTREY III ,o Lic. No.0402052122 06/10/2020 JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 TITLE SHEET Tmi oR�P,�E Rock 2 / 50 U•S / / / \ PROPOSED LESSEE 30' x 30' LEASE AREA P.O.B. IVAG NAIL(F) / = IN PAVED DRIVEWAY L1 IVIF ROBERT L. & ✓EANNE K. CROSS TR. OF CROSS LIVING TRUST PARCEL ID 05700 00-G. 00-041LO \ PARCEL Y" rl PROPOSED 20' LESSEE INGRESS \ UTILITIES EASEMENT EGRESS o � / / N/F N/F ROBERT L. & ✓EANNE K. CROSS ✓OHN & MAE✓E OVERTON TT OF CROSS LIVING TRUST PARCEL 'k'" SHOWN PER D.B. JO55, PG. 236 O.B. 5075, PG. 390 D.B. 3606, PG. 391 PARCEL ID 05700-00-00-041GO PARCEL ID 05700-00-00-041LO AS RESERVED FOR DEDICATION UPON DEMAND \PARCEL X' OF THE COUNTY LINE rAHLE LINE BEARING DISTANCE L 1 N 28'29'07" E 21.28' L2 S 41°31'12" E 163.48' L3 N 44.06'05" E I12.63" L4 N 01.3624" W 9,71' L5 N 48.4945" W 80.51' L6 N 6171'33" E 21.51' L7 S 48'49 "45 " E 81.90' L8 S 01 °36 24 " E 26.88' L9 S 44.06"05" W 142.65' L 10 N 47.31 "12" W 17779" LII IN 28.38 27 W 30.00 L12 1 N 67.21'33' E 30.00' L 13 IS 28.38 27 ' E 30.00' L 14 IS 61'21 33 " W 30. 00' CR%PHIC SCALE 1 "=40' 0' 40' 80' 120' w Niami'C7 z TOTALLY COMMITTEDL w RR+C ENGINEERING �oSERVICES, LLC. verizon/ 1831 RADY COURT RICHMOND, VA 23222 z WILD TURKEY 0 NB+C PROJECT#100374 #426 ROCKFISH GAP TURNPIKE z CHARLOTTESVILLE, VA 22903 w ALBEMARLE COUNTY 7 REVISIONS 1 19WI91 REV. EASE RW 0 BB/19 EASEMENT IXHIBIT RW DATE I DESCRIPTION OBERT T. WILLIAMS, JR.- LIC. No. 002551 9-30-2019 SURNE oO_wO t0nts P.C. S._. Land Surveyors VA&NC P.0 BO% 15039 I I VA. N PHESNUKE. PHONE: ]5]-482-04]4 0474 msumms 11 mm ! II EASEMENT II EXHIBIT EE-1 EXHIBIT NOTES 1. TOPOGRAPHIC SURVEY PERFORMED BY CAUSEWAY CONSULTANTS, P.C. P. 0. BOX 15039. CHESAPEAKE, VIRGINIA, 23328-50394. PHONE: 757-482-0474. SURVEY DATE: JULY 15, 2019. 2. COORDINATES AND ELEVATIONS SHOWN WERE ESTABLISHED USING STATIC GPS OBSERVATIONS, POST PROCESSED THROUGH NOAA'S OPUS WEBSITE AND CONVERTED TO NAVD 88 AND NAD 83, U.S SURVEY FOOT, FOR THE VERTICAL DATUM AND HORIZONTAL COORDIANTES, RESPECTIVELY, USING U.S. ARMY CORPS OF ENGINEERS CORPSCON SOFTWARE, VERSION 6.01 AND PUBLISHED BENCHMARKS. 3. NO SUB —SURFACE INVESTIGATION WAS PERFORMED BY CAUSEWAY CONSULTANTS, P.C. THIS EXHIBIT DOES NOT GUARANTEE THE "EXISTENCE OR NONEXISTENCE" OF UNDERGROUND UTILITIES. PRIOR TO ANY CONSTRUCTION OR EXCAVATION, CONTACT MISS UTILITY AT 1-800-552-7001 TO CONFIRM THE LOCATION OR EXISTENCE OF UNDERGROUND UTILITIES. 4. THIS EXHIBIT WAS DONE WITH THE BENEFIT OF A TITLE REPORT BY US TITLE SOLUTIONS, FILE No. 63455—VA1906-5010, REF. No. 18082-2nd PARCEL, DATED JUNE 19, 2019. 5. PROPERTY IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 6. THIS EXHIBIT DOES NOT REPRESENT A BOUNDARY SURVEY. THE RIGHT—OF—WAY, PROPERTY LINE AND/OR EASEMENTS SHOWN HEREON REPRESENT A COMPILATION OF RECORDED DEEDS, PLATS, G.I.S. RECORDS AND TAX MAPS. 7. THE AREA OF THE PROPOSED CELL TOWER APPEARS TO LIE WITHIN FLOOD ZONE "X", ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY — NATIONAL FLOOD INSURANCE COMMUNITY NUMBER 51003C-0245 D, DATED FEBRUARY 4, 2005. 8. THE EXISTENCE OF HAZARDOUS WASTE, VEGETATED WETLANDS, OR TIDAL WETLANDS, WAS NEITHER INVESTIGATED, NOR CONFIRMED DURING THE PERFORMANCE OF THIS EXHIBIT. LEGAL DESCRIPTION PROPOSED LESSEE 30' x 30' LEASE AREA A PROPOSED LESSEE 30' x 30' LEASE AREA ON PARCEL "Y" AS SHOWN ON THAT CERTAIN MAP RECORDED IN DEED BOOK 1055 AT PAGE 234, OF RECORD IN THE CLERK OF THE CIRCUIT COURTS OFFICE, ALBEMARLE COUNTY, VIRGINIA; BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS; BEGINNING AT A MAG NAIL IN THE NORTHWESTERLY MOST CORNER OF PARCEL "X" AS SHOWN ON SAID MAP, THENCE ALONG A RE LINE N 74'04 21 ' E A DISTANCE OF 13720' TO A POINT BEING THE TRUE POINT AND PLACE OF BEGINNING; THENCE N 28°38 27" W A DISTANCE OF 30.00' TO A POINT, THENCE N 6121 33" E A DISTANCE OF 30.00' TO A POINT, THENCE S 28`38 27" E A DISTANCE OF 30.00' TO A POINT, THENCE S 61 21 33" W A DISTANCE OF 30.00' TO A POINT WHICH IS THE TRUE POINT AND PLACE OF BEGINNING, HAVING AN AREA OF 900 SQUARE FEET LEGAL DESCRIPTION PROPOSED LESSEE 20' INGRESS/EGRESS AND UTILITIES EASEMENT A PROPOSED LESSEE 20' INGRESS/EGRESS AND UTILITIES EASEMENT OVER AND ACROSS PARCEL X" AND PARCEL "Y" AS SHOWN ON THAT CERTAIN MAP RECORDED IN DEED BOOK 1055 AT PAGE z 234, OF RECORD IN THE CLERK OF THE CIRCUIT COURTS OFFICE, ALBEMARLE COUNTY, VIRGINIA; z BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS; w BEGINNING AT A MA NAIL /A/ THE NORTHWESTERLY MOST CORNER OF PARCEL 'X" AS SHOWN ON SAID MAP, THENCE ALONG U.S. ROUTE 250, LOCALLY KNOWN AS ROCKFISH GAP TURNPIKE N 2829'07" E A DISTANCE OF 27.28' TO A NAIL; THENCE LEAVING SAID U.S. ROUTE 250, S 41°31'12" E A DISTANCE OF 163.48' TO A POINT, THENCE N 44'06'05' E A DISTANCE OF 112.63' TO A POINT, THENCE N 01 °36 24 " W A DISTANCE OF 9.71 ' TO A POINT, THENCE N 48'4945" W A DISTANCE OF 80.51' TO A POINT, THENCE N 61'21 '33" E A DISTANCE OF 21.31 ' TO A POINT; THENCE S 48°49'45' E A DISTANCE OF 81.90' TO A POINT, THENCE S 01 °36 24 " E A DISTANCE OF 26.88' TO A POINT,• THENCE S 44'06'05" W A DISTANCE OF 142.65' TO A POINT, THENCE N 41 °31 '12' W A DISTANCE OF 177.79' TO A POINT WHICH IS THE POINT OF BEGINNING, HAVING AN AREA OF 7,955 SQUARE FEET OR 0. 183 ACRES. 0 0 z_ Naml'= TOTALLY COMMITTEDl. NB+C ENGINEERING SERVICES, LLC. verizon/ 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY NB+C PROJECT#100374 #426 ROCKFISH GAP TURNPIKE 1ARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 0 8 w ¢ 0 0 1 9/30/19 REV. EASE RW 0 BV19 EASEMENTEXHIBIT RW REV DATE DESCRIPTION BY fH OF G �PZ I � / C_�ROBERT T. WILLIAMS, JR.a LIC. No. 002551 9-30-2019 lgNO SUR\J oOausewa Consultants P.C. Land Surveyors VA&NC ¢ N P.0 P E5 A PHONE 75E, VA. 23348 PHONE: ]5]-482-04]4 0=45wr r a � EASEMENT F w EXHIBIT w m z EE-2 2 0_' 0 z LEI \\\ \\\\ \x�\\\ \\\\\\\ O\ \ \ \\\1\\ 111 \ �/ I\ 1 >>i//j/llllllllllllJlllj IIII l� ljllll////_�_ �j�I— �'-- \ j' /il l/j/////j�//�\✓%//j%///////���//ll�l1 Ill j((IIIII////// / �''/ ���\\�\\\\)\\\\\\ r�\_- / \ I \/ \\\\ \\� \ \ \ \\\ �(��� \�� ��\///���(\✓^IIII 1\I1(///) /ll ( /Wm,// / // / / �/ \ �// / / I I I 1\\\\ I / // / —�;\ \1\ \ I (\ \\\\\\ ////////j _ 1f (l7/ /////IIII/1() l/\ //0ll/7/(7/l1( ( 1 \ —\—_� J 11\\ /// l \I 1 )��r/( ) �Il�jl�l/\\\/i%/J/I(11/!j \\ �%//i/ ���/ii% = l/ \\�\J'\\\\\\\�\\ 1 I I I / I / /' \ \\/// �\ ` — ///%/� / \\ ^ II 11 /%��//\� /\\)Illjll(/J/ // ////%%/////iii///i///'/'-- /// \ \IIII( /1111111 l I \\\\\\\\\\\\\\ 1 j / rY \l lj/l �� / /% —\ \�\1``�\ \ \I \\II Il/////7 \ \ \ \\\ I //// < / \ \ \\\\��\\\\\\�\ \\\\\\\\\\\ / Imo\ lI-='���i=iii ��\` \\ r 1 \II%I)%/%%/ _�! > j/�/> \���\\\ \\_ \\�\\\\ I / ---'�/ // �/\ \\\\\\\\\\ill \\\�\\\� /i//� �11\I��'\l///r-_��///�/x 7—I--= iA -rt-jT\// I/////� 0 II11111 /// /__- I\IIIIII 1 j I l // `���___ \\\ 1l/ll / 1 //////i//!�/��iiir//�//�//\ \ 1 Il j jljlJlll(Ij(�j////IZY ll )1 I I I l \ _ //� / / I �/ �j l //\\/ �\ (((\ ���\�\N\\\\\\\1\\\N\\- /////%�///IIII`(( \\�\\ \1 l I / \— — _ /( l i/\\\�/ /i/ / /�\\\\\��\�\\� fix\\\<^ \\ \\�\\ /i//I / (° o i/ 7//i� \/��i^\\\\\\\\\\�\\\�\\\ X\xNN // //////// ////—\ l////J�/7jl%%l!r�_I �\\\\\\\��\\�\�=—_�i��i�/ ��//� \/ �/i�%ii//\ \�•,II l r\��/// /i��J\��/1���% /i\ \\ \\\\ \\��Q\\\I \\\� I� �jIIIIII �iI(I( / ii'/i / \ \\\ /I III/1�=--J/ //J111 L( ����\-�i�___'�\\\\\�\\\Q\�\�`� II II IIII111111\)111\1\ll \ / // / �T —\ >>�\ %�\��`_� \�\\\\\\\��=_=IIIII\\\\\\\�\\\\`�_� I \\\\ \ ) 1 \\\\II\ \0\\ // l l l 1 / / 1) I l/ l/ / l / /// / / J � /// i _ _ I ll / I I 1 \\\ \\\\\\\\\\\t / —\ / I/I1��IIII`(�\\I 1 \ ( \ I\\\ ice / 1 1 \\ / I / / N — /)/' (/J//' �'\\\I \ \ \ \ \ III III// / �-- \ \ \ \ / II III111111111111111111 / 1 � _ / \_ / II111111//I) % ,�/ r / / / \\ / 11 I I I I(�A 1 II II t \ \ \ \ \ 1 1111111111111111111111111)117// / \ I--r �/ / SEE SHEET // \\\ IIII IIIII(�\I III \ \ \ \� /' /IIIII 1 II (IIIII II I III I 1 III III / 1 // _�� \\\II 14 \\-rll+�l� t! ��� �� 11L—�- —I— ) C-1 FOR \ \ \ ( z — I( Il I ll '\\\ \\\ \ ( DETAILS — — �/ /iii � I I III II \ � �� � /J�J // � I I %,� J _IIIII /, / ___ II \\� I / III �'� JIIIIIIIIII\\\II\\ �\ > / j% /// /\\�\�\\�\\\\\\0\�\�\���\�\�\\ ///%/// // ICI II / /�/��� \\\�\�\ \\o\\���\��N�\ \ 11 I 1\\\\\\\\\\\\\\\ \ \\ l / (11/ I(/////////i\,j)/I\\\\\\�\\\\\\\\ \\\\\\\\\��/l////////// II III\I11\\<\\\\\ 1IIN III(II\((1�/i^\llll��\\� \\\\\\ i r �\x\\�_= _= === ===== _���\\�— / 2018 4' CONTOURS \\�\ —\\ \\� RLE �\\\\�_=_ — ����\ FROM ALBEMA --ZSj \1 COUNTY GIS ul \Illllr _ / \\\ \\\\\� 1 \ \\\Illllllllllll ))l JJz GRAPHIC SCALE 2,0001 TOPO BOUNDARY 200 D 00 200 400 800 Z-1 SCALE:1"=200' (IN FEET) 1 INCH = 200 FEET 4SZ) 56-100A 34 ,.,., 35:07 57-39 56102 \ T® 561026j 4839 . r3 VICINITY MAP SITE �o � 4'4 sr-Hc P3'5)-4u. aoe 5) 41K 3�3 37,5 5) 41 �-I w Ir q\1 TM LLI TOTALLY COMMITTED. z w NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 IIII' verizon'll a_ Q 1831 RADY COURT RICHMOND, VA 23222 GENERAL NOTES 1. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF z RECORD. 0 2. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM Q WILD TURKEY THIS FACILITY. m WILD TURKEY LANE 3. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN LL CHARLOTTESVILLE, VA 22903 HABITATION. THERE IS NO HANDICAP ACCESS REQUIRED. z LU ALBEMARLE COUNTY 4. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. LEGEND PROPERTY LINE — SUBJECT PARCEL PROPERTY LINE — ABUTTERS EXISTING ROAD EXISTING FENCE — — — — — — PROPOSED EASEMENT 0 PROPOSED LEASE AREA EXISTING EASEMENT PROPOSED FENCE EXISTING BUILDING Know what's below. Call before you dig. REVISIONS 0 6 1 06/10/20 1 REVISED CT Cc 0 5 04/20/20 REVISED CCC LU cc 4 03/09/20 REVISED PJP Z 3 02/24/20 REVISED PJP LU 2 12/04/19 REVISED CCC 0 a Q Z O U) U) LLJ LL Ir LLI LLJ Z Z LLJ LU J w LU rr LU m z LU LU C/J 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD LJS REV I DATE I DESCRIPTION I BY r44,, 0 H O p Dr�� o x 9 JOHN A. DAUGHTREY III Lic. No. 0402052122 06/10/2020 Way JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 29000 TOPO BOUNDARY Z=1 VICINITY MAP 5 100F II .521 � SITE OA el 57 a9n 499 Z 30 W \ EXISTING FENCE "'0'> / / / // / , 3�0 5r-39 LINE (TYP) 3.7_0 �� , n 56.102 !� P EXISTING CARRIER FENCED � COMPOUNDS W/ TO X X X G (TYP OF 2) // '// '/J '// '/, '// '// '// '// '/J '///, j 3'S o _ �19ze ,,,,, , / / / / / / 4839 ` /, VERIZON WIRELESS 30x30' 0 0� 0 OVERHEAD EXISTING - LEASE AREA FOR UTILITIES BUILDING (TYP.) EQUIPMENTI LAW' COMPOUND ' VERIZON WIRELESS 116.7' \ \ MONOPOLE TOWER WITHIN 30 x30 LEASE AREA �, / � � � � � � � � GENERAL NOTES NIF TEMPLE HILL HOLDINGS LLC 240 BROAD AXE RD 00 z '/, EXISTING CRITICAL / / / / / / / / / '/. '// '// '// '// '// CHARLOTTESVILLE VA, 22903 % % % % % % % % % 1. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. SLOPES(TYP) � '''' PARCEL ID#•05700-00-00-04100 %%% %%%%%%%%% LI m VERIZON WIRELESS 20' WIDE ACCESS AND UTILITY EASEMENT EXISTING TREE LINE (TYP) EXISTING PROPERTY ACCESS DRIVE EXISTING PROPERTY FENCE LINE N/F OVERTON, JOHN & MAEVE OVERTON 429 WILD TURKEY LANE CHARLOTTESVILLE VA, 22903 PARCEL ID If.- 05700-00-00-041GO ZONING.- N/A ACREAGE.- 3.06t ACRES I I II I I I I \ 1 \ j Ir > /ro I/ EXISTING I/ RESIDENTIAL BUILDING DDRESS 804) ZONING: N/A i /. % % % % % % % % % % / / / / / / / % % % % / / 2 NO SIGNIFICANT NOISE, SMOKE, DU OR ODOR WILL RESULT FROM I T E E, DUST, ACREAGE- 87.31fACRES THIS FACILITY. 3. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN HABITATION. THERE IS NO HANDICAP ACCESS REQUIRED. 4. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. /// //////// X/0 X/ X/0X, X/ X/0 5. BUILDING AND ELECTRICAL PERMITS ARE REQUIRED FOR THE TOWER, 0 '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, ANY STRUCTURE GREATER THAN 150 SQ. FT. HOUSING EQUIPMENT AND ELECTRICAL SERVICE. ROBERT L & JEANNE K CROSS TRUSTEES OF THE CROSS LIVING TRUST 635 BOONE TRAIL CHARLOTTESVILLE, VA 22903 PARCEL ID #: 05700-00-00-041L0 ZONING: RS1-RESIDUALI ACREAGE: 6.0t ACRES '/, '/, '/, '/, ♦ '/, '/, '/, '// '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '// '/, '/, '/, '/, '/, '/, '// '/, '/, '/, , 'r.�� ', '/, '/, '/, , , x , , , , , , , , , , '/, '/, '/, /, '// 0 '// '/, '/, '/, /, '// 0 '// '/, '/, '/, /, '// 0 '// '/, '/, '/, /, '// '/, '// '/, '/, '/, /, '// 0 '// 0 0 '/, /, 0 0 0 '/,\'/, '/, /, 0 '/, 0 '/, 0 EXISTING TREE LINE (TYP) ////////'-0i; ,/00/ /////////////////////000 000000 //// sT), / �?ppF'� 100 YEAR FLOOD N/F CROSS, ROBERT L & ✓EANNE K CROSS /, , , , , , , , , , , , , , , , , , 'T ?1�G(�, , � , , , , , , , , , , , , , , , , , , , , , , , , , PLAIN TRUSTEES OF THE CROSS LIVING TRUST 1G 635 BOONE TRL CHARLOTTESVILLE VA, 22903 PARCEL ID #• 05700-00-00-041 KO ZONING: N/A ACREAGE.- 15.Of ACRES '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, '/, �� '/, '/, '/, '/, '/, WATER PROTECTION '/, /, 0 '/, 0 0 0 '/, /, 0 0 0 0 0 '/, /, 0 0 0 0 0 '/, /, 0 0 0 0 0 0/,�i �( 0 ORDINANCE BUFFER GRAPHIC SCALE 1 SITE PLAN 50 0 25 50 '°° 200 C 1 SCALE: 1"=50' (IN FEET) 1 INCH = 50 FEET ZONING INFORMATION JURISDICTION: ALBEMARLE COUNTY ZONING: RA (RURAL AREA) DIMENSION REQUIREMENT PROPOSED i FRONT YARD SETBACK: SIDE YARD SETBACK: REAR YARD SETBACK: 75' 25' 35' 136'-0" 28'-5" 186'-1" LOT AREA: 6.0 t ACRES (ALL MEASUREMENTS ARE IN FEET t UNLESS OTHERWISE NOTED) I m LLI LU z z W z U_ a_ D- Q z O D- 0 z Lu cn 0 cr 0 Lu W 0 m LLJ W Z z Lu Lu J w LJ U) m LJ m z W Lu U) 7N TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonil 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 1 06/10/201 REVISED I CT 5 1 04/20/20 1 REVISED I CCC 4 1031091201 REVISED I Pip 3 1 02/24/201 REVISED I Pip 2 1 12/04/19 1 REVISED I CCC 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD LJS REV DATE DESCRIPTION BY �o���PtiT H 0 JOHN A. DAUGHTREY III Lic. No. 0402052122 06/10/2020 W� JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 SITE PLAN cmi Z / W / / / / / for EXISTING REFERENCE TREE 4199 (113'+AGL) 00, op I 19 / �G / PROP/ / f % \ \ EXISTING FENCE LINE (TYP) \ \ \ F\ EXISTING CARRIER FENCED AS'oo COMPOUNDS W/ TOWERS (TYP OF 2) F\ I O 00 VERIZON WIRELESS 30'x30' LEASE ° / AREA FOR EQUIPMENT COMPOUND 0 OVERHEAD ♦ ' / UTILITIES VERIZON WIRELESS 116.7' MONOPOLE TOWER WITHIN `\ r 30'x30' LEASE AREA o� %.'�xoVERIZON WIRELESS 12' WIDE GRAVEL ACCESS ROAD ♦ I / ♦ I � ♦ / PROPOSED EVERGREEN TREE INIA CEDER TO EARRANGEDTO LIMIT / / ' % / El / COMPOUND VIEW (TYP. OF 4) VERIZON WIRELESS 20' WIDE ' / r ACCESS AND UTILITY EASEMENT N/F OVERTON, ✓OHN & MAEVE OVERTON 429 WILD TURKEY LANE CHARLOTTESVILLE VA, 2290J PARCEL ID #• 05700-00-00-041GO ZONING: N/A ACREAGE- 3.06f ACRES EXISTING PROPERTY ACCESS DRIVE EXISTING PROPERTY 1 ENLARGED SITE PLAN 20 C 2 SCALE: V=20' FENCE LINE GRAPHIC SCALE 0 10 20 40 (IN FEET) 1 INCH = 20 FEET 80 �1- EXISTING BUILDING (TYR) ROBERT L & JEANNE K CROSS TRUSTEES OF THE CROSS LIVING TRUST 635 BOONE TRAIL CHARLOTTESVILLE, VA 22903 PARCEL ID #: 05700-00-00-041LO ZONING: RS1 - RESIDUALI ACREAGE: 6.0± ACRES 7 7)8' �9+ VICINITY MAP 10OF 4�23 SITE _--- 61 A 4l \ gam/ 4 J � 4 57-41L, 57a9a I 56102 326 30' 57 39 3L7_0 57 41K 3�3 3 7�5 4e 39 :III�:7_1��C�ir m LU LU z z LU TIN 1 TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizom/ 1831 RADY COURT RICHMOND, VA 23222 1. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF z RECORD. O Q WILD TURKEY 2. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. WILD TURKEY LANE 3. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN CHARLOTTESVILLE, VA 22903 HABITATION. THERE IS NO HANDICAP ACCESS REQUIRED. z ALBEMARLE COUNTY LU 4. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. PROPERTY LINE — SUBJECT PARCEL PROPERTY LINE — ABUTTERS EXISTING ROAD —••— EXISTING FENCE — — — — — — — PROPOSED EASEMENT PROPOSED LEASE AREA EXISTING EASEMENT PROPOSED FENCE EXISTING BUILDING Know what's below. Call before you dig. REVISIONS 6 06/10/20 REVISED CT 0 1 1 m O 5 04/20/20 REVISED CCC U LLJ 4 03/09/20 REVISED PJP z 3 02/24/20 REVISED PJP LU 2 12/04/19 REVISED CCC 1 1 11/18/19 1 FINALS I CCC 1 10/30/19 1 PRELIMINARY CD LJS I0 REV DATE DESCRIPTION BY a- PITH CF G I < U�O /jSi /JA 19 C9 2 z O JOHN A. DAUGHTREY III Lic. No.0402052122 U) A� 06/10/2020 w� IDNAL z I I JOHN A. DAUGHTREY III, P.E. (D I I VA PROFESSIONAL ENGINEER LIC. #052122 n LU J II ENLARGED Uj I I SITE PLAN m LU m z C=2 LU W CO IN TM Know what's below. Call before you dig. I to EXISTING FENCE 30' LEASE AREA/COMPOUND r-----------------------------------------------------� I 1 � 1 1 4' TO PAD 0 0 0 0 13 0 0 0 0 0 PROPOSED VERIZON 00 a PROPOSED VERIZON WIRELESS EQUIPMENT N a - 0 WIRELESS GPS ANTENNA CABINET ON CONCRETE PAD I �o o 0 o fa 00o \FF a LLI UJI PROPOSED VERIZON e Of z WIRELESS ICE BRIDGE TO MONOPOLE TOWER M N N d 6 2 U O 0 y:. .. :'. O 0 .. 0 0 01 CENTER OF MONOPOLE TO PAD 0 0 0 4' 15' .+ PROPOSED VERIZON WIRELESS 116.7' MONOPOLE TOWER PROPOSED VERIZON WIRELESS 12' WIDE GRAVEL ACCESS ROAD -----------r----- ---- PROPOSED 5' H-FRAME FOR \ POWER SUPPLY ` OHW p H p PROPOSED VERIZON WIRELESS ` 0Hw p 25'X30' WOODEN FENCED COMPOUND PROPOSED VERIZON p p p WIRELESS 12' WIDE DOUBLE p p SWING ACCESS GATE p p —pHw EXISTING p p UTILITIES POLE TO \ m, p p REMAIN � p p p COMPOUND PLAN C 3 SCALE: 3/8" = V-0" PROPOSED VERIZON WIRELESS GENERATOR ON CONCRETE PAD 0 0 3' PROPOSED VERIZON WIRELESS MESA CABINET ON STRONGWELL ❑Hw � M PROPOSED VERIZON p"w ❑Hw � WIRELESS DISCONNECT ❑Hw GRAPHIC SCALE 2 0 1 2 4 8 (IN FEET) 3/8 INCH = 1 FOOT EXISTING OVERHEAD UTILITIES \ PROPOSED VERIZON WIRELESS 20' WIDE ACCESS/UTILITY EASEMENT CE LU Lu z TOTALLY COMMITTED. z Lu NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 ■ verizonit J Q 1831 RADY COURT RICHMOND, VA 23222 Q I I WILD TURKEY 7 I I WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 Lu ALBEMARLE COUNTY 1 REVISIONS 6 06/10/20 REVISED CT Q 1 1 0 5 04/20/20 REVISED CCC U Lu 4 03/09/20 REVISED PJP Z 3 02/24/20 REVISED PJP WQ 2 12/04/19 REVISED CCC Q Q Z O U) U) LLI Ll O Cc 0_ cz Lu Lu z z Lu J LU U) m Lu m z Lu Lu U) 1 1 11/18/191 FINALS I CCC 1 1 0 1 10/30/19 1 PRELIMINARY CD I LJS 1 REV I DATE I DESCRIPTION I BY JOHN A. DAUGHTREY III Lic. No. 0402052122 .?� 06/10/2020 Wa JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 COMPOUND PLAN C=3 N1931imEw TM NOTE: w 1. EXTREME CARE SHALL BE TAKEN NOT TO DAMAGE EXISTING TREES THAT ARE TO REMAIN. .- LU 2. CONSTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OR COMPENSATION OF DAMAGED TREES. dPdo00000, z TOTALLY COMM DT TED. 3. SITE SHALL BE MAINTAINED IN ACCORDANCE WITH A TREE CONSERVATION PLAN TO BE PREPARED 6�6 / z BY A CERTIFIED ARBORIST. AS REQUIRED BY SEC.5.1.40(C)(4). /./ 6��j do w NB+C ENGINEERING SERVICES, LLC. 4. TRIM EXISTING BRANCHES THAT ENCROACH INTO THE FENCED IN COMPOUND AREA. / -- 4435 WATERFRONT DRIVE, SUITE 100 / GLEN ALLEN, VA 23060 185 -' 804-548-4079 187 -.00e • EXISTING REFERENCE TREE / / .� #199 (113 ±� AGL) /' / / - 191 do /_. - o ■ 193 � z verizon i- 0189 U / 0 195 O �i� a_ c / . / ,+ J 1831 RADY COURT Q z / / 199 SO RICHMOND, VA 23222 z / / o / . • O / 2010-/ - 183 / 203 O z O 205 O 0 -� 244 O / 207 / 79 Q WILD TURKEY WILD TURKEY LANE p CHARLOTTESVILLE, VA 22903 ,�.� 242 0 209 ���� 177o 181 w ALBEMARLE COUNTY �' PROPOSED VERIZON 116.7' \1 MONOPOLE TOWER / 213 / l / 0211 �� 1 / op do 175 p • 215 o REVISIONS -� i \el '- �O \ 0 6 06/10/20 REVISED CT 027 0� \ cr - A 155 \ 0 5 04/20/20 REVISED CCC /-- �� \ \ EXISTING cc: LU 4 03/09/20 REVISED PJP o� \ \ TREE 219 157 \ \ (TYP.) 3 02/24/20 REVISED PJP -- /� \ \ 0 2 12/04/19 REVISED CCC 221 ,�+ O �/ 159 ,�\ ,�\ 173 1 11/18/19 FINALS CCC \ p 0 10/30/19 PRELIMINARY CD US 223 /�' \ \\ O 171 ; �� p REV DATE DESCRIPTION BY 161 /� ; O 225 \ \ 169 /' ��` \ \, 0 227 163 \`.\ i : �1 P1 H Op Gr Q% o �� \167 O I 0 U JOHN A. DAUGHTREY III 9 � Lic. No. 0402052122 \ / 0 238 JLL \ W �O 06/10/2020 �W \ 229 \ °: / / % , / OOC sIONAL \ / / \ / \ ' j'/ �\ 240 � � / LU z JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 z \ LL PROPOSED EVERGREEN \, TREE (VIRGINIA CEDAR) \ \ (TYP. OF 4) % / / w 66 TREE INVENTORY LU w \ ccf) \ \ w GRAPHIC SCALE m 1 TREE REMOVAL PLAN 2 D 6 2 24 48 z SCALE: 1" = 12' Know what's below. LU C4 w 1 INCHC=4 IN FEET) LU FEET Call before you dig. TREE INVENTORY NUMBER SPECIES CALIPER AGL HEIGHT CANOPY HEIGHT (155*) OAK 24" 86' 756' AMSL (157) OAK 24 97' 762' AMSL (159) LOCUST 24 81' 749' AMSL (161) LOCUST 36" 76' 744' AMSL (163) CEDAR 10" 43' 711' AMSL (167) PINE 15" 47' 721' AMSL (169) OAK 15 64' 740' AMSL (171) OAK 12 62' 742' AMSL (173) OAK 12 65' 741' AMSL (175) LOCUST 12" 73' 750' AMSL (177) LOCUST 10 57' 735' AMSL (179) LOCUST 10" 63' 740' AMSL (181) LOCUST 10" 60' 738' AMSL (183) OAK 50" 82' 762' AMSL (185) OAK 15" 99' 773' AMSL (187) OAK 36" 100' 773' AMSL (189) PERSIMMON 15" 90' 762' AMSL (191) OAK 20" 94' 764' AMSL (193) OAK 20" 80' 751' AMSL (195) OAK 20" 89' 759' AMSL (197) OAK 20 113' 774' AMSL (199) OAK 24" 113' 774' AMSL (201) CEDAR 20" 41' 709' AMSL (203) OAK 10" 73' 738' AMSL (205) OAK 24" 85' 750' AMSL (207) OAK 12" 94' 753' AMSL (209) OAK 48 106' 768' AMSL (211) OAK 15" 81' 742' AMSL (213) OAK 30" 120' 776' AMSL (215) OAK 15" 100' 753' AMSL (217) OAK 15" 85' 743' AMSL (219) OAK 20" 70' 721' AMSL (221) OAK 24" 94' 748' AMSL (223) OAK 24" 96' 754' AMSL (225) OAK 20" 74' 728' AMSL (227) OAK 24" 95' 751' AMSL (229) OAK 15" 89' 747' AMSL (238) OAK 20" 81' 741' AMSL (240) OAK 20" 86' 749' AMSL (242) LOCUST 12" 75' 746' AMSL (244) LOCUST 18" 70' 741' AMSL *TOTAL TREES TO BE REMOVED: 1 155 NOTES: 1. REFERENCE TREE IS IDENTIFIED ABOVE IN BOLD. 2. TREE DRIPLINES ARE DRAWN TO SCALE. 3. UNDERLINED TREE HEIGHTS HAVE BEEN CONFIRMED BY A THIRD PARTY TOWER CLIMB. ELEV.=0.0' AGL (661.0 AMSL) w Uj w o� Q w U -H Z w o� I w w ow �Of TOP OF PROPOSED VERIZON MONOPOLE ELEV.=116.7' AGL (784.0' AMSL) PROPOSED ANTENNAS (TYP. OF 6) PROPOSED SITE PRO 1-COMPACT MONOPOLE MOUNT PART # UWS6-NP (TYP. OF 2) PROPOSED OVP (TYP. OF 2) PROPOSED SITE PRO 1-RING MOUNT PART # UGLM-DCP PROPOSED VERIZON WIRELESS HYBRID CABLES TO RUN INSIDE MONOPOLE PROPOSED VERIZON WIRELESS 117' MONOPOLE TOWER EXISTING REFERENCE TREE (#199) 25' MAX TO DRIPLINE OF REFERENCE TREE PROPOSED OUTDOOR EQUIPMENT 8 1 ELEVATION C 5 SCALE: 1/8" = 1' 51 GRAPHIC SCALE 4 8 16 (IN FEET) 1 INCH = 8 FEET PROPOSED 2' LIGHTNING ROD, 1" DIAMETER BASE, TAPERING TO A POINT PROPOSED 3.5" SCH 40 PIPES. 18' LONG TO SPAN THE TWO SITE PRO 1-COMPACT MONOPOLE MOUNTS. PART # UWS6-NP (TYP. OF 6) PROPOSED OVERALL TOWER HEIGHT ELEV.=118.7 AGL 786.0 AMSL PROPOSED TOP OF TOWER ELEV.=116.7 AGL 784.0 AMSL PROPOSED VERIZON RAD CENTER ELEV.=112.7 AGL 780.3 AMSL PROPOSED RRH MOUNT CENTERLINE ELEV.=102 AGL 769.3 AMSL PROPOSED OVP MOUNT CENTERLINE ELEV.=94 AGL 761.3 AMSL PROPOSED 2" STD PIPES. 6' LONG. (TYP. OF 3) NOTE: ALL VERTICAL CABLES TO RUN INSIDE MONOPOLE FROM GROUND LEVEL TO ANTENNA ELEVATION 32 NOTE: 1. THE PROPOSED ANTENNAS & RRHs WILL BE PAINTED THE COUNTY APPROVED COLOR SHERWIN WILLIAMS JAVA BROWN #6090. 2. ANTENNAS WILL BE INSTALLED USING A MODIFIED FLUSH DESIGN WITH LOW PROFILE MOUNTING BRACKETS. NO POINT ON THE BACK OF ANTENNAS SHALL BE MORE THAN 18" FROM FACE OF MONOPOLE. PROPOSED SITE PRO 1-COMPACT MONOPOLE MOUNT PART # USW6-NP (TYP. OF 2) ELEV.=Off AGL (667.3 AMSL) (POSED 116.7' MONOPOLE AZIMUTHS TBD I I O II 15 15 z WN (A cn X Q 00 N PROPOSED VERIZON ANTENNA (TYP. OF 6) PROPOSED MONOPOLE MOUNT ANTENNA ORIENTATION PLAN AT 113' NTS GENERAL NOTES 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITIES COMPANY OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 8. TRANSMITTER EQUIPMENT AND ANTENNAS ARE DESIGNED TO MEET ANSI/TIA 222-G REQUIREMENTS. 9. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 10. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 11. IF ANY UNDERGROUND UTILITIES OR STRUCTURES EXIST BENEATH THE PROJECT AREA, CONTRACTOR MUST LOCATE IT AND CONTACT THE APPLICANT & THE OWNER'S REPRESENTATIVE. 12. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION BY TECHNICIANS APPROXIMATELY 2 TIMES PER MONTH. 13. PRIOR TO THE INSTALLATION OF THE PROPOSED EQUIPMENT OR MODIFICATION OF THE EXISTING STRUCTURE, A STRUCTURAL ANALYSIS SHALL BE PERFORMED BY THE OWNER'S AGENT TO CERTIFY THAT THE EXISTING/PROPOSED COMMUNICATION STRUCTURE AND COMPONENTS ARE STRUCTURALLY ADEQUATE TO SUPPORT ALL EXISTING AND PROPOSED ANTENNAS, COAXIAL CABLES AND OTHER APPURTENANCES. 14. PROPERTY LINE INFORMATION WAS PREPARED USING DEEDS, TAX MAPS, AND PLANS OF RECORD AND SHOULD NOT BE CONSTRUED AS AN ACCURATE BOUNDARY SURVEY. 15. THIS PLAN IS SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. 16. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 17. NO SIGNIFICANT NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 18. THE FACILITY IS UNMANNED AND NOT INTENDED FOR HUMAN HABITATION (NO HANDICAP ACCESS REQUIRED). 19. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 20. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. NOTE: THE TOWER STRUCTURE HAS NOT BEEN EVALUATED BY NETWORK BUILDING AND CONSULTING ES AND WILL NEED TO BE ANALYZED WITH ALL PROPOSED LOADING BY A PROFESSIONAL ENGINEER PRIOR TO INSTALLATION. Know what's mow. Call before you dig. LU LI z_ 0 z LI z O Q m O ILL z Li m 0 LI rT- 0 co w 0_ CJ J z O U) U) w LL D_ Ir w w z_ 0 z w o- w m z w w co TM TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonit 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 1 06/10/201 REVISED I CT 5 1 04/20/20 1 REVISED I CCC 4 103/09/201 REVISED I Pip 3 1 02/24/201 REVISED I Pip 2 1 12/04/19 1 REVISED I CCC 1 1 11/18/19 1 FINALS I CCC 1 0 1 10/30/19 1 PRELIMINARY CD I US REV I DATE I DESCRIPTION BY OF 7 7 o � XA JOHN A. DAUGHTREY III „0 Lie, No. 0402052122 �O 06/10/2020 1, nA7Al JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 TOWER ELEVATION, DETAILS & NOTES C=5 NOTE: TWO OF THESE MOUNTS ARE REQUIRED FOR THIS SITE. THE (6) 3.5" SCH. 40 X 18' LONG PIPE MOUNTS ARE SOLD SEPARATELY. THE PIPE MOUNTS WILL SPAN BETWEEN THE TWO COMPACT MONOPOLE MOUNTS AS SHOWN ON SHEET C-2 SITE PRO 1-COMPACT MONOPOLE MOUNT (PART # UWS6-NP) NOTE: CONTRACTOR TO PROVIDE SITE PRO 1-COMPACT MONOPOLE MOUNT (PART # UWS6-NP) OR APPROVED EQUIVALENT ANTENNA & RRH MOUNT DETAIL SCALE: NTS PROPOSED 116.7' MONOPOLE PROPOSED VERIZON WIRELESS OVP (1 TOTAL ON TOWER) SITE PRO 1-RING MOUNT (PART # UGLM-DCP) �n /I APPROX TRUE NORTH PROPOSED OVP ORIENTATION PLAN - 95' MOUNT CENTER OW (3) PROPOSED 2" STD PIPES. 6' L OR SITE PRO 1-RI (PART # UGLM-DCP) NOTE: CONTRACTOR TO PROVIDE SITE PRO 1-RING MOUNT (PART # UGLM-DCP) OR APPROVED EQUIVALENT 2 OVP MOUNT DETAIL C-6 SCALE: NTS �-OMPACT RUNT (PART (12 TOTAL ON TOWER) PROPOSED RRH ORIENTATION PLAN - 102' RAD CENTER 0101 APPROX TRUE NORTH 15.73" RAYCAP OVP BOX #RHSDC-3315-PF-48 NTS (12 TOTAL ON TOWER) PACT f (PART PROPOSED RRH ORIENTATION PLAN - 102' RAD CENTER NTS APPROX TRUE NORTH m LL I W Z_ 0 Z LU z O Q m 0 LLJ 0 0 Lu CL Z 0 U) Lu r) Q Q Z O U) LLI LL O rr 0- m w w Z_ C.3 Z Lu 0 Lu m z Lu w U) �1 TM TOTALLY COO MMMEM NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonil 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 06/10/20 REVISED CT 5 04/20/20 REVISED CCC 4 03/09/20 REVISED PJP 3 02/24/20 REVISED Pip 2 1 12/04/19 1 REVISED I CCC 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US REV I DATE I DESCRIPTION I BY �o���PtiT H OF G Jac ol— � 9 JOHN A. DAUGHTREY III Lic. No. 0402052122 .� 06/10/2020 Wat JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 MOUNT DETAILS C=6 10' (H-FRAME W/ICE BRIDGE) 10' (CONCRETE PAD) RESERVED SPACE FOR EQUIPMENT PROPOSED VERIZON WIRELESS 4'X10' CHARLES CABINET ` H-FRAME POST #1 CONCRETE PAD FOR EQUIPMENT 18"x18" HOFFMAN BOX 24" WIDE ICE BRIDGE OVER H-FRAME EQUIPMENT AS NEEDED ON THIS SIDE MOUNT LIGHT SWITCH W/ TIMER ON END POST 24" WIDE ICE BRIDGE OVER H-FRAME EQUIPMENT SWITCH/TIMER CHARLES CUBE #RL1003C-A EXCHANGER (120V) W/ TF UPS PART #SM1500RMXL2UT/ 18%18" HOFFMAN PROPOSED VERIZON WIRELESS GPS ANTENNA ATS/AC ILC v. . C7 OVID 6 ° 0 D 100 1 1 EQUIPMENT LAYOUT PLAN S-1 NTS REAR " ° D ° ° D - o D D p v D v D. I• v 7Iv i i (4) 1"0 ANCHOR HOLES FOR 6"X18" CONDU STUB -UP OPENIt v D p D D D D Dv v a D PROPOSED EQUIPMENT CABINET H-FRAME RISER DETAILS NTS OVP 6 v �D TM VERIZON WIRELESS EQUIPMENT: - CHARLES INDUSTRIES CUBE-SS48231 PX2 EQUIPMENT Lu CABINET WITH BATTERY CABINET INCLUDED Lu z TOTALLY COMMITTED. z Lu NB+C ENGINEERING SERVICES, LLC. CONTRACTOR PROVIDED EQUIPMENT: 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 * THIS IS NOT A COMPREHENSIVE LIST. IT SHOULD BE ASSUMED BY THE CONTRACTOR THAT ALL OTHER ITEMS DETAILED IN THIS SET OF DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR. 0 a - 26.2" WIDE X 78" TALL X 12.3" DEEP, ASCO D300L SERIES w POWER TRANSFER LOAD CENTER MODEL AA300G-1PH-N-3R - "ILC' INTEGRATED LOAD CENTER WITH COMBINATION PADLOCK. U o 22" WIDE X 26" TALL X 2 DEEP, CHARLES INDUSTRIES < CHANGER (120V) W/ CUBE-RL1003C-A W/ HEAT EXCHANGER C z verizonit TRIPP-LITE UPS PART #SM1500RMXL2UTAA INSIDE U (ONLY REQUIRED WHEN VzT PROVIDES LIT FIBER. UTILITY J COORDINATOR MUST VERIFY IF THIS IS NEEDED) Q 1831 RADY COURT - RAYCAP OVP-6 (RCMDC-3315-PF-48) RICHMOND, VA 23222 - COORDINATE ADDITIONAL ENTRY GATE LOCK(S) WITH CONSTRUCTION MANAGER. FRONT NOTES: 1. SEE SHEET E-1,E-2 & E-3 FOR FOR CABLE/CONDUIT ROUTINGS. 2. BOTTOM OF OVPs SHALL NOT EXCEED 36" ABOVE FINISHED GRADE. Q I I WILD TURKEY � I I WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 Lu ALBEMARLE COUNTY REVISIONS 6 06/10/20 REVISED CT Q 0 5 04/20/20 REVISED CCC C) LLI 4 03/09/20 REVISED PJP Z 3 02/24/20 REVISED PJP W 2 12/04/19 REVISED CCC 1 1 11/18/191 FINALS I CCC 10/30/19 1 PRELIMINARY CD I US I0 REV DATE I DESCRIPTION I BY � 4�'0H OF DJ Q yO Y III� UDAUGHTREY 2 aEQUIPMENT W '4�H-FRAMEti�POST #1 OTC AL D SWITCH/TIMER Lu Lu z z JOHN A. DAUGHTREY III, P.E. (3 VA PROFESSIONAL ENGINEER LIC. #052122 Lu Lu EQUIPMENT Lu MOUNTING Lu DETAILS m Smi Lu m z co 6" 3'-0" 10'-0" (H-FRAME W/ICE BRDIGE) 3'-0" 3'-0' L O I N I I I 0 12"0 H-FRAME J N FOUNDATION (SEE i 3/S-4 FOR DETAILS) EQUIPMENT J H-FRAME POST #1 i4 M '� M z (4) 1 "0 ANCHOR HOLES FOR 5/8" EXPANSION ANCHOR BOLTS Mi 9y 6"X18" P CONDUIT STUB -UP OPENING G 10'-0" (CONC. PAD) .. . A .. . ,•.t•., .• ;.•.Y EQUIPMENT CABINET 1 EQUIPMENT PLAN S-2 SCALE: NTS 10' 3' PROPOSED TEVERIZON 10'X4' CONCRETE PAD #4 REBAR W/ 3" CLEAR FROM (4,000 PSI CONCRETE) EDGES (TYP. TOP & BOTTOM) 00 �'.d du: I°. I.d d.l a I •a _.I. d .. I �° a .I •d I . • e •. a :. r7°0N---I= fi—=--I�--4{ ad l7r— a 1 d•. -le' �.. 9 EQUAL SPACES AT 1'-O" 6" �a 3 CONCRETE PAD DESIGN S-2 SCALE:NTS 8" MIN. FILL VOID WITH #57 GRAVEL AFTER CONDUIT INSTALLATION 2" PROPOSED R CONCRETE PAD a a a c d Q d d Q d d O I e d o- e.• d • . (f d . NEW CONDUITS 10" COMPACTED #57 GRAVEL GENERATOR CONDUIT ROUTING DETAIL IN 3" (TYP.) a N IN W 0 m m V) !n m O w 0 10'-0" 6" �-- 3'-0" -i - 3'-0" - I~ 3'-0" ---� 6" 24" WIDE ICE BRIDGE N I (D UNISTRUT PIPE/CONDUIT CLAMP P1119 OR 02558-35 (GALV.) (TYP). FOLLOW MANUFACTURER RECOMMENDATIONS FOR POST (TYP) BOLT TORQUE P1000 1 5/8" X 1 5/8" 12 GAGE CHANNEL STEEL UNISTRUT (TYP) PIPE 3 STD 13'-4" LONG ICE BRIDGE POST (TYP) - P2860-10 END CAP (TYP) EQUIPMENT H-FRAME - POST #1 (CLOSEST TO BTS EQUIPMENT PAD) w R w N 0 0 -- FINISH SUBGRADE 00 I M TI � 1'-0"0 CAST -IN -PLACE 4000 PSI (TYP) CONCRETE FOUNDATION (TYP) 2 H-FRAME DETAIL S 2 NTS #4 AT 12" O.C. EACH WAY FOR GENERATOR PAD. SEE 2/S-3 FOR EQUIPMENT PAD SPACING (TYP. TOP AND BOTTOM) (4,000 PSI CONCRETE) NOTE: THIS DESIGN ASSUMES A iv 2000 psf SOIL BEARING PRESSURE ey CD R V ,. R _j M O COMPACTED #57 GRAVEL 4 CONCRETE PAD FOUNDATION S 2 SCALE: NTS "HILTI" KWIK BOTL 5/8"0 STAINLESS STEEL EXPANSION ANCHOR BOLT O ml A v 11•/16"0 DRILLED HOLE d EXPANSION ANCHOR DETAIL CONCRETE GENERAL NOTES 1. ALL CONCRETE WORK SHALL CONFORM TO ACI 318, "BUILDING CODE L TM REQUIREMENTS FOR REINFORCED CONCRETE" AND TO THE PROJECT Jill SPECIFICATIONS. LLI ft%j LLJ 2. ALL CONCRETE IS TO BE NORMAL DENSITY CONCRETE WITH A z 70TQL LY CCDO uvu M 177E D. MAXIMUM SLUMP OF 4 INCHES. MAXIMUM AGGREGATE SIZE 3/4 INCH. CD NO ADDITIONAL WATER SHALL BE ADDED TO THE CONCRETE AT THE z JOB SITE. w NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 3. PROVIDE AIR ENTRAINMENT OF 4 TO 6 PERCENT IN ALL EXPOSED GLENALLEN, 23060 804-548-407079 CONCRETE WORK WITH AIR -ENTRAINING ADMIXTURE COMPLYING WITH ASTM C 260. AT TROWEL -FINISHED FLOORS, DO NOT EXCEED AIR -ENTRAINMENT CONTENT OF 3 PERCENT. 4. NO HOLES OR SLEEVES SHALL BE MADE THROUGH CONCRETE WORK OTHER THAN THOSE INDICATED ON THE STRUCTURAL DRAWINGS WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. 5. ALL FORMWORK OFFSET TOLERANCES (PER ACI 117) TO BE CLASS A. 6. FLOOR SLAB TOLERANCES TO ASTM E1155; SPECIFIED OVERALL Q verizonit MINIMUM VALUE OF FLATNESS F F=25 WITH LOCAL MINIMUM F F=17, AND MINIMUM VALUE OF LEVELNESS F F=20 WITH LOCAL MINIMUM F I U AND F F WITHIN 72 HOURS OF SLAB CONSTRUCTION. 7. CABINETS ON SLAB (IF APPLICABLE). ALLOWABLE CAPACITY OF Q 1831 RADY COURT CONCRETE USED IN DESIGN MIN. 3500 PSI. RICHMOND, VA 23222 FOUNDATION NOTES: 1. DESIGN INFORMATION AND GENERAL REQUIREMENTS 1.1 CODES A. DESIGN CONFORMS TO INTERNATIONAL BUILDING CODE 2015. z B. AMERICAN CONCRETE INSTITUTE "BUILDING CODE REQUIREMENTS FOR O REINFORCED CONCRETE," ACI 318-24. Q WILD TURKEY 2. EARTHWORK WILD TURKEY LANE 2.1 FOUNDATIONS CHARLOTTESVILLE, VA 22903 A. FOUNDATIONS HAVE BEEN DESIGNED TO BEAR ON (UNDISTURBEDLi ALBEMARLE COUNTY RESIDUAL SOILS/COMPACTED STRUCTURAL FILL), CAPABLE OF SAFELY UJ SUPPORTING A NET ALLOWABLE BEARING PRESSURE OF 2000 PSF. IF FOUNDATION CONDITIONS PROVE UNACCEPTABLE AT ELEVATIONS SHOWN, EXCAVATION SHALL BE CARRIED DEEPER AND SHALL BE BACKFILLED WITH LEAN CONCRETE TO PLAN FOOTING BOTTOM, OR REDESIGN OF FOUNDATIONS WILL BE REQUIRED AT THE DIRECTION OF REVISIONS THE ENGINEER. B. DESIGN, FURNISH AND INSTALL ALL TEMPORARY SHEETING, SHORING AND DRAINAGE NECESSARY TO MAINTAIN THE EXCAVATION AND PROTECT SURROUNDING STRUCTURES AND UTILITIES. 6 06/10/20 REVISED CT C. THOROUGHLY COMPACT ALL BOTTOM OF FOOTINGS PRIOR TO PLACING O ANY CONCRETE. 5 04/20/20 REVISED CCC U 3. CONCRETE � 4 03/09/20 REVISED PJP z 3.1 FORMWORK 3 02/24/20 REVISED PJP U) c/� A. CONCRETE CONSTRUCTION SHALL CONFORM TO "SPECIFICATIONS FOR Lu 2 12/04/19 REVISED CCC STRUCTURAL, CONCRETE FOR BUILDINGS," (ACI 301-89). 1 11/18/19 FINALS CCC B. FORMWORK SHALL CONFORM TO ACI 301 "SPECIFICATIONS FOR 0 10/30/19 PRELIMINARY CD US STRUCTURAL CONCRETE FOR BUILDINGS." 3.2 REINFORCEMENT REV DATE DESCRIPTION BY A. REINFORCING STEEL ASTM A615, GRADE 60. WELDED WIRE ASTM A185 (FLAT SHEET). LAPS 40 BAR DIAMETERS UNLESS NOTED. BARS SHALL BE SECURELY HELD IN ACCURATE POSITION BY SUITABLE ACCESSORIES, TIE BARS, SUPPORT BARS, ETC. HOOK LENGTHS SHALL BE 12 BAR DIAMETERS. B. CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS, 2 111 ti, H OF GJ UNLESS OTHERWISE NOTED. Q FOOTINGS & SLABS CAST AGAINST GROUND . . . . . . . . 3" CONCRETE TO BE IN CONTACT WITH GROUND OR WEATHER AT Q BARS GREATER THAN #5 . . . . . . . . . . . . . . . . . . 2" AT BARS #5 OR LESS . . . . . . . . . . . . . . . . . 1-1/2" Q JOHN A. DAUGHTREY III CONCRETE NOT TO BE EXPOSED TO GROUND OR WEATHER U) A Lic. No. 0402052122 a BEAMS, GIRDERS & COLUMNS . . . . . . . . . . . . . 1-1/2" U) �'� 06/10/2020LLI �W SLABS & WALLS . . . . . . . . . . . . . . . . . . . . . .3/4" LL 3.3 CAST -IN -PLACE -CONCRETE c SI0 L A. MINIMUM 28 DAY CYLINDER STRENGTH AND MAXIMUM SLUMP, PRIOR TO ADDITION OF SUPER PLASTICIZERS, AS FOLLOWS: F'C PSI SLUMP CLASS I FOOTINGS . . . . . . . . . . . . . 4000 3" CLASS II FOOTINGS . . . . . . . . . . . . . 4000 3" CLASS III INTERIOR ELEVATED . . . . . . . 4000 4" SLABS & WALLS LLJ CLASS V OTHER WORK 4000 4" z JOHN A. DAUGHTREY III, P.E. CLASS VI LEAN CONCRETE FOR OVER 0 VA PROFESSIONAL ENGINEER LIC. #052122 EXCAVATION OF FOUNDATIONS . . . . . . 2000 z N/A L1 B. MIX DESIGN TO BE IN ACCORDANCE WITH ACI 318, CHAPTER 5. NO CALCIUM CHLORIDE OR ADMIXTURE CONTAINING CHLORIDES SHALL BE USED IN ANY CONCRETE. C. COARSE AGGREGATE FOR NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C33 SIZE #57. COARSE AGGREGATE FOR LIGHT WEIGHT w CONCRETE SHALL CONFORM TO ASTM C330 GRADED 3/4" TO 1/4". _j CONCRETE PAD D. COLD WEATHER PLACEMENT SHALL COMPLY WITH ACI 306.1 t E. HOT WEATHER PLACEMENT SHALL COMPLY WITH ACI 305 R. = DETAILS U) F. CHAMFER ALL EXPOSED EDGES 3/4". G. THE MAXIMUM TEMPERATURE OF ALL CONCRETE AT DELIVERY TO THE SITE SHALL BE 85'F, TOTAL DELIVERY TIME SHALL BE LESS THEN 75 MINUTES. LI..I m z � w 2 U� PROPOSED MONOPOLE ROUTE CABLES UP THROUGH POLE TO RAID CENTER PROPOSED GROUND BAR STRAPPED TO POLE PROPOSED COAX/HYBRID CABLE (TYP.) NOTE: THIS VIEW IS FOR GENERAL CABLE ROUTING DETAILS ONLY. REFER TO 2/S-1 FOR SPECIFIC H—FRAME EQUIPMENT LAYOUT. PROPOSED VERIZON EQUIPMENT H—FRAME PROPOSED VERIZON ICE BRIDGE 1 1 EQUIPMENT ELEVATION S-3 NTS C:@=Co= 0 PROPOSED OVP 2 1 H-FRAME SIDE ELEVATION NTS E ICE BRIDGE ACH SIDE fED BY 2 POST MIN.) 1 5/8" STEEL DST (TYP) TM m Lu Lu z TOTALLYCOMMITTED. Z Lu NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 ■ U verizonit D_ Q 1831 RADY COURT RICHMOND, VA 23222 Q I I WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 Lu ALBEMARLE COUNTY L 0 Ir 0 O Lu WAVEGUIDE BRIDGE KIT OR 0= APPROVED EQUAL Z CD CfD Lu 0 5/8"0 THREADED ROD — 18" LONG ALL THREAD SAFETY D_ CAPS 5/8"0 Q STRUCTURAL NOTES oI 40 J o ALV GALVANIZEZED GALVANIZE Z STEEL PIPE 1. DESIGN REQUIREMENTS PER INTERNATIONAL BUILDING CODE 2015 AND O THE ANSI/TIA-222-G STRUCTURAL STANDARDS FOR STEEL ANTENNA U) TOWERS AND ANTENNA SUPPORTING STRUCTURES. uJ 2. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED BY FIELD 24" �I LL O MEASUREMENT AND FROM THE EXISTING STRUCTURAL DRAWINGS. THE co GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND MOUNT POINTS 24" WIDE GALVANIZED NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO WAVEGUIDE CHANNEL ORDERING MATERIALS OR PROCEEDING WITH CONSTRUCTION. W/ 11/16"0 HOLES CUT TO SUIT 3.STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE (TYP. OF 2) AISC SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS — ALLOWABLE 71 STRESS DESIGN AND PLASTIC DESIGN INCLUDING THE COMMENTARY AND THE AISC CODE FOR STANDARD PRACTICE. 4.STRUCTURAL STEEL PLATES AND SHAPES SHALL CONFORM TO ASTM CROWN Lu Lu A36. ALL STRUCTURAL STEEL PIPES SHALL CONFORM TO ASTM A53 5/8"OX2'—O" THREADED FOOTING Z GRADE B. ALL STRUCTURAL STEEL COMPONENTS AND FABRICATED ROD W/ NUTS & (� ASSEMBLIES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION. OVERSIZED WASHERS Z (TYP of 2) III _ -III _ -III- _ _— - Lu 5. WELDING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AMERICAN WELDING SOCIETY (AWS) STRUCTURAL WELDING CODE — UNISTRUT CABLE 1 STEEL WELD ELECTRODES SHALL BE E70XX. SUPPORT ® 3'-0" OC MAX OR APPROVED ? II- 6. ALL COAXIAL CABLE CONNECTORS AND TRANSMITTER EQUIPMENT SHALL EQUAL ° BE AS SPECIFIED BY THE OWNER AND IS NOT INCLUDED IN THESE d CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL FURNISH ALL a Lu CONNECTION HARDWARE REQUIRED TO SECURE THE CABLES. ih 3000 PSI MIN. J CONNECTION HARDWARE SHALL BE STAINLESS STEEL. 3 CABLE SUPPORT SECTION _ i CONCRETE NTS FOOTING w 7. ALL THREADED STRUCTURAL FASTENERS AND THREADED ROD FOR S 3 104 - Lu ANTENNA SUPPORT ASSEMBLIES SHALL CONFORM TO ASTM A307 OR a " ASTM A36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL C= FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8" 1 i NOTE: MIN. DIAMETER BEARING TYPE CONNECTIONS WITH THREADS INCLUDED a `--J ° ALL SUPPORT POSTS IN THE SHEAR PLANE. ALL EXPOSED FASTENERS, NUTS AND WASHERS a ° MUST BE GROUNDED SHALL BE GALVANIZED UNLESS OTHERWISE NOTED. CONCRETE EXPANSION ANCHORS SHALL BE HILTI KWIK BOLTS UNLESS OTHERWISE 1' NOTED. Lu m 8.NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY TRUE NORTH AND INFORM CONSTRUCTION 4 CABLE BRIDGE DETAIL z MANAGER OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. S 3 NTS W Lu U) REVISIONS 6 106/10/201 REVISED I CT 5 1 04/20/20 1 REVISED I CCC 4 103/09/201 REVISED I Pip 3 102/24/201 REVISED I Pip 2 112/04/19 1 REVISED I CCC 1 111/18/19 1 FINALS I CCC 0 1 10/30/19 1 PRELIMINARY CD I US REV I DATE I DESCRIPTION I BY [ H O F G% ,A JOHN A. DAUGHTREY III Lie, No. 0402052122 06/10/2020 1' O7V A 7 JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 CONSTRUCTION DETAILS & NOTES S=3 UNDISTURBEC SOIL MIP M �I (TYP.) 2-GANG METER BANK H-FRAME NIS BOARD -ON -BOARD WOODEN FENCE INTERMEDIATE, GATE & CORNER POSTS BOARD ON BOARD 8' WIDE GATE LEAF ZRESISTANT 2@@�490 1 /2"X4"PULL SLOT 0.5 CDF SKID SURFACE COVER BOX INSERTS (4) CONCRETE FOOTING (4000 PSI O 28 DAYS, PORTLAND CEMENT CONCRETE) 1 5/8"0 PIPE FRAME GATE WITH MECHANISM 1 5/8"0 PIPE FRAME GATE WITH MECHANISM GALVANIZED MUSHROOM STOP jSEE 4/S-2 FOR DETAILS =� o� 10" 04 8'-0" 8'-0" 16'-0" FRONT GATE TYPICAL FENCE AND GATE DETAIL NTS f -1 11-1 I I-1 I I-1 I I a II —III —III —III I o `° II 11111111111111111111111 1 =111=1 1=1 1=1 1=111 CONCRETE RING AROUND BOX COMPOSOLITE BOX AND COVER COMPACTED EARTH NOTES: 1. CONCRETE ENCASEMENT TO BE 3,000 P.S.I. MINIMUM. 2. CONCRETE ENCASEMENT RING DIMENSION, D, TO BE EQUAL TO DESIGN PAVEMENT DEPTH. 3. PAVEMENT AND SUBGRADE TO BE AS SHOWN ON THE ENGINEERING PLANS. 4. QUAZITE DOES NOT RECOMMEND THE USE OF CONCRETE OR POLYMER CONCRETE BOXES IN HIGH VOLUME TRAFFIC APPLICATIONS. 1CTOR TO ORDER HANDHOLE TH THE CORRECT NUMBER ZE OF KNOCKOUTS NEEDED. 2. VERIFY DIMENSIONS OF UNIT. 2 HANDHOLE DETAIL S-4 NTS STOCKADE WOODEN FENCE 12' 6' MAX TYPICAL GATE DETAIL S 4 NTS 8'-0" O.C. (MAX.) (3) INDUSTRIAL MALLEABLE IRON OFFSET PIN HINGES PER GATE PANEL 2X4 (TYP) GRADE 6"X6" PRESSURE TREATED WOOD POST (TYP.) 1/2" CROWN FOR DRAINAGE 2" GAP BETWEEN EXTEND STONE 1'-O" WOOD PANEL AND GRAVEL`S BEYOND FENCE ON ALL 4 SIDES DRILLED PIER 4000 PSI CONCRETE. EMBEDDED UPORTION OF ALL POSTS SHALL BE GENEROUSLY COATED WITH WOOD PRESERVATIVE FENCE & GATE NOTES: 1 PROVIDE HALF MOON CONCRETE GATE KEEPER FOR DROP ROD 2. PROVIDE GATE CATCHES AT REQUIRED LOCATIONS 3. FENCE SHALL BE INSTALLED WITH THE FINISHED SIDE FACING OUTWARD 4. GATE TO BE SECURE WITH A MULTI -LOCK SYSTEM TO PREVENT UNAUTHORIZED ACCESS TO TELECOM FACILITY. MESA SPAN 7N I AMP FUSIBLE :ONNECT w W TOTALLY COMMITTED Z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 CUSTOMER ACCESS BOX CUSTOMER verizon J ACCESS CONDUITS Q J w Q 1831 RADY COURT RICHMOND, VA 23222 1/2-13 UNC X 1-3/4 STAINLESS STEEL HEX HEAD CAPTIVE BOLT (TYP OF 2) 5/8" X 1" THRU SLOT WITH 1-1/4- X 1-5/8" X 1/2- DEEP C'BORE (TYP OF 2) 3;oy Q WILD TURKEY 1/2" STAINLESS STEEL FLAT m WILD TURKEY LANE WASHER (TYP OF 2) 5'° CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY -;. QUAZITE LOGO SKID RESISTANT SURFACE MS-86 1" X 4" PULL SLOT WITH 1/4" CENTER PIN (2) 1/2" PAL NUT (TYP OF 2) 24" CABLE RACK (TYP OF 3) n � 5 �O 22" CABLE RACK (TYP OF 4) / 4" X 4-1/2" X 9" MOUSEHOLE KNOCKOUT (2 EACH END WALL) �7 FULL COVER P/N PG3660C527VY COVER GUARD STRUT (TYP OF 2) 3 �O '�� BMT BRACKET 0 ih 1 /2" THRU HOLE (FOR EXCESS GROUND RIBBON) TERMINATOR FOR 4" CONDUIT (TYP OF 8) 4 MESA CABINET DETAIL S-4 NTS 6" AASHTO #57 CLE GEOTEXTILE FABRIC s GRAVEL COMPOUND DETAIL S-4 NTS REVISIONS 6 06/10/20 REVISED CT 0" 5 04/20/20 REVISED CCC U W 4 03/09/20 REVISED PJP Z C3 3 02/24/20 REVISED PJP C1� W 2 12/04/19 REVISED CCC D_ Q Z 0 0) U) W w W W w Z_ U Z w Lu J w W 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD LJS REV DATE DESCRIPTION BY r4,7011 O F D%%% 0XA JOHN A. DAUGHTREY III .,� Lic. No.0402052122 06/10/2020 <v� ilXIA1 .a JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 CONSTRUCTION DETAILS S=4 (4) 1"0 ANCHOR HOLES FOR 5/8" EXPANSION ANCHOR BOLTS Ln Ln ° d d I III 6"X18" CONDUIT a STUB —UP OPENING d a 4 44.45 e a ° 44 0 0 0 0 0 0 0 0 e. o ad Q 4 9.49 .d 0 0 0 0 n 4 4 a c6 aN a 0 ° ° Q ..4 da GENERATOR PLACEMENT ON CONCRETE PAD NTS j L 2.13 AIR INTAKE DUCTS BLUE BACKGROUND W/ BLACK LETTERING 32.01 DANGER DIESEL FUEL KEEP FIRE OR FLAME AWAY NO SMOKING RED BACKGROUND W/ BLACK LETTERING YELLOW BACKGROUND W/ BLACK LETTERING WHITE BACKGROUND W/ BLACK LETTERING 2 SIGNAGE DETAIL S-5 NTS FREEZE PLUG BLOCK HEATER LOCATED BEHIND OIL FILTER ENGINE OIL FILTER HOUSING AIR CLEANER RESTRICTION INDICATOR AIR CLEANER HOUSING 0 0 0 REMOVABLE ALTERNATOR ACCESS PANEL DEC 3000 CONTROL PANEL LOAD CIRCUIT BREAKER 150A AIR INTAKE DUCTS 30 U FUEL FILTER CRANKCASE OIL DIPSTICK KOHLER 30KW VERIZON DIESEL GENERATOR DETAIL NTS WHITE W/ 2" HIGH RED LETTERING NO SMOKING 3 SIGNAGE DETAIL S 5 NTS %IR DISCHARGE LIFT OFF SERVICE PANELS W/ LOCKABLE LATCHES OIL FILL 00 00 r RADIATOR FILL 4 OIL DRAIN VALVE 17.78 38.13 76.18 COOLANT DRAIN VALVE DANGER 203 GALLON DIESEL TANK NO SMOKING 4 SIGNAGE DETAIL S-5 NTS TM CE Lu W W TOTALLY COMMITTED Z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonl/ D_ Q 1831 RADY COURT RICHMOND, VA 23222 ll Q I I WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 w ALBEMARLE COUNTY 1 REVISIONS 6 06/10/20 REVISED CT If Q 5 04/20/20 REVISED CCC U W 4 03/09/20 REVISED PJP Z 3 02/24/20 REVISED PJP UJ W 2 12/04/19 REVISED CCC 0 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US REV DATE DESCRIPTION BY � PITH OF G t oho X A 2 z U JOHN A. DAUGHTREY III � Lie. No. 0402052122 w �'� 06/10/2020 ww LL jONAL Lu II LuLu JOHN A. DAUGHTREY III, P.E. Z (3 1 1 VA PROFESSIONAL ENGINEER LIC. #052122 II W W II GENERATOR I I DETAILS Ir W CO Z S=5 Lu Lu TP, � pHW r----------- I I I I I PROPOSED VERIZON WIRELESS ICE BRIDGE ABOVE H—FRAME EQUIPMENT PROPOSED VERIZON WIRELESS ICE BRIDGE TO MONOPOLE TOWER PROPOSED VERIZON WIRELESS 116.7' MONOPOLE ----------------------------------------- I I I I r— PROPOSED VERIZON WIRELESS EQUIPMENT CABINET PROPOSED (1) 1" SCH. 40 PVC CONDUIT W/ (2) #10 + (1) #10G FROM UPS IN CHARLES CUBE TO TELCO DISCONNECT (25' LONG) m PROPOSED VERIZON WIRELESS 3.5'X8' CONCRETE PAD FOR _L a GENERATOR PROPOSED (1) 2" SCH. 40 PVC CONDUIT W/ (3) #3/0 + (1) #613 FOR ELECTRIC SERVICE FROM DISCONNECT TO ILC (23' LONG) PROPOSED VERIZON WIRELESS 5' H—FRAME FOR POWER SUPPLY p pHW + \ OHW -pHW PROPOSED VERIZON WIRELESS 12' WIDE ACCESS GATE \ 1 ELECTRICAL PLAN E 1 SCALE: 1" = 8' e L -GF PROPOSED MESA CABINET ON STRONGWELL GRAPHIC SCALE 4 8 16 (IN FEET) 1 INCH = 8 FEET LL 0 LL 0 �F J PROPOSED (1) 2" SCH. 40 PVC CONDUIT FOR TELCO SERVICE W/ 1000 LB MULETAPE & COPPERHEAD TRACER WIRE OUTSIDE TRENCH FROM PROPOSED MESA CABINET TO 18"X18" HOFFMAN BOX (31' LONG) pHW � pHW - pHW ------- 32 NOTE: CONSTRUCTION MANAGER & UTILITY COORDINATOR TO ORDER POWER & TELCO SERVICES AT ONSET OF CONSTRUCTION. ROCKFISH GAP TURNPIKE (STATE RT 250) 00007 ---- ----------- I pHW -OHW j/ PROPOSED VERIZON WIRELESS 30'X30' FENCED COMPOUND Q \\ WITHIN 30'x30' LEASE AREA o 0 Q1 LL w 1\ PROPOSED VERIZON \ WIRELESS 116.7' EU 1 MONOPOLE \ 5 \ I pHb{ \ LL w \ pHW \ pHW - \\ \ � -pHW - \ `, 1 I' pHw —pHW PROPOSED (2) 2" PVC CONDUIT FOR TELCO FROM MESA CABINET TO R.O.W. \ \ \ I i PROPOSED (1) 4" PVC CONDUIT FOR LOCAL LL w CAL POWER UTILITY CONNECTION \ 1 ` PROPOSED TRANSFORMER TO R.O.W. \ \ I \ \ 1 LL w \ \ PROPOSED VERIZON WIRELESS 12' WIDE ACCESS DRIVE \\ PROPOSED VERIZON WIRELESS 20' \ I \ WIDE ACCESS AND UTILITY EASEMENT z LL PROPOSED TELCO FIBER \ \ HANDHOLE ® R.O.W. THE EXISTING UTILITY INFORMATION SHOWN REPRESENTS THE BEST DATA AVAILABLE FROM EXISTING DOCUMENTATION AND FIELD EVIDENCE. ALL LOCATIONS SHOULD BE CONSIDERED APPROXIMATE, AND A FIELD INVESTIGATION MUST BE PERFORMED IN THE VICINITY OF ANY CONSTRUCTION ACTIVITIES. NOTE THAT THESE PLANS MAY NOT SHOW ALL UTILITIES THAT ARE PRESE3NT AT THE SITE. 2 OVERALL ELECTRICAL PLAN E-1 SCALE: 1" = 50' GRAPHIC SCALE 50 0 25 50 100 200 (IN FEET) 1 INCH = 50 FEET Know what's below. Call before you dig LLI W Z_ (5 z LLI z 0 0 z w TOTALLY COO MMIT7ED NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizom/ I 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 06/10/20 REVISED CT 0 Cr 5 04/20/20 REVISED CCC U LLJ m 4 03/09/20 REVISED PJP z 3 02/24/20 REVISED PJP LU 2 12/04/19 REVISED CCC LU Lu z z LLI w J w LU W m Z LI..I W co 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US REV DATE DESCRIPTION BY TH OF XA� JOHN A. DAUGHTREY III Lic. No.0402052122 -P 06/10/2020 w44 � ��ssf OXF A l 1 r -Om JOHN A. DAUGHTREY III, P.E. I VA PROFESSIONAL ENGINEER LIC. #052122 ELECTRICAL PLAN & DETAILS Emi (1) 1" CONDUIT FROM CHARLES CUBE UPS TO MESA CABINET DISCONNECT PROPOSED VERIZON WIRELESS UPS CHARLES CABINET 2 PROPOSED FENCE LINE 12" L 0 SELECT GRANULAR BACKFILL COMPACTED TO 85% AASHTO #57 GRAVEL SURFACING 6" DEEP BACKFILL TO MEET EXISTING FINISH GRADE FINISHED GRADE ;��i�pi�pi�� UNDISTURBED SOIL o: i��i��i✓ WARNING TAPE FOR UNDERGROUND UTILITIES %'.:. r (TYP) 2" PVC M CARRYING TELCO SERVICE AASHTO #10 DUST 1" PVC CARRYING 2" PVC 12' 12" ELECTRIC TO MESA CARRYING ELECTRIC MI IN 6" MIN CABINET SERVICE (TYP) (TYP) NOTE: 1. EXCAVATE EXISTING SUBGRADE AS REQUIRED TO INSTALL CONDUITS IN ACCORDANCE WITH OSHA AND ALL APPLICABLE CODES. �E EI E y y� 18"x 18" 1// '--' HOFFMAN BOX g F F F- F o O 2" CONNECTION B/W (2) 2" FIBER CHARLES CABINET CONDUITS FROM AND HOFFMAN BOX HOFFMAN BOX TO MESA CABINET PROPOSED VERIZON WIRELESS GPS ANTENNA 1 TYPICAL TRENCH DETAIL E 2 NTS 24" WIDE ICE BRIDGE OVER H-FRAME EQUIPMENT a F ATS/AC ILC 2 ELECTRICAL PLAN E 2 SCALE: 1" = 1' F OVP 6 F F v F`IF PROPOSED EQUIPMENT CABINET PROPOSED VERIZON WIRELESS 4'X10' CONCRETE PAD FOR EQUIPMENT IM � I p D 2 / CONDUITS TO BE / INSTALLED BELOW GRADE / i 0 GRAPHIC SCALE 0 0.5 1 2 (IN FEET) 1 INCH = 1 FEET p v v D -.D - v - D. � p v D V D - D - - -D p _ � v D D D D" v D D 4 NOTES: 1. WHEN EQUIPMENT FRAME IS INSTALLED ADJACENT TO CABINET PAD, INTERCONNECTING CONDUITS SHALL BE INSTALLED AT OR ABOVE GRACE. 2. BELOW GRADE CONDUIT SHALL BE SCHEDULE 80 PVC. ABOVE GRADE CONDUIT SHALL BE GALVANIZED RIGID CONDUIT. BELOW GRADE PVC CONDUIT SHALL TRANSITION TO GRC PRIOR TO RISING ABOVE GRADE. ALL BENDS SHALL HAVE A MINIMUM 24" RADIUS. ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. VERIFY CONDUIT TYPE WITH LOCAL CONSTRUCTION MANAGER AND ADJUST IS NECESSARY. ALL CONDUIT SHALL MEET NEC, STATE, AND LOCAL CODE REQUIREMENTS AS REQUIIRED. TM m LL I w TOTALLY COMMITTED. z LI NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 ■ U verizonit EL Q 1831 RADY COURT RICHMOND, VA 23222 z O Q WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA22903 EQUIPMENT CONDUIT SCHEDULE LLI ALBEMARLE COUNTY FIBER CONDUITS U) 1�(1) 2" SCH. 40 PVC CONDUIT W/ MULETAPE FROM HOFFMAN BOX TO THE EQUIPMENT CABINET 2� (1) 1-1/2" LMFC FOR FIBER & ALARM FROM EQUIPMENT CABINET TO OVP-1 REVISIONS AC POWER CONDUITS E(4) 1" CONDUIT W/ (8) #10 + (1) #10G FROM THE ILC TO THE EQUIPMENT 6 06/10/20 REVISED CT CABINET FOR (4) 30 AMP 2-POLE CIRCUITS. 1 OF THE 4 CONDUITS TO HOUSE (2) #12 + (1) #10G FOR (1) 20A CABINET RECEPTACLE BREAKER. 0 0 5 04/20/20 REVISED CCC D �(1) 1-1/2" CONDUIT W/ (3) #1/0 + (1) #6G FROM ILC TO GENERATOR z 4 03/09/20 REVISED PJP 5❑ (1) 1" CONDUIT W/ (4) #12 + (1) #12G FROM ILC TO GENERATOR (GEN HEATER & BATTERY CHARGER) 0 3 02/24/20 REVISED PJP 6� (1) 2" CONDUIT W/ (3) #3/0 + (1) #6G FROM ILC TO METER/DISCONNECT LU 2 12/04/19 REVISED CCC D 1 11/18/19 FINALS CCC 7� (1) 1-1/2" LMFC W/ (12) #6 (6 PAIRS) + (1) #6G FROM EQUIPMENT CABINET TO OVP 0 10/30/19 PRELIMINARY CD US E] (1) 1" CONDUIT W/ (3) #12 + (1) #12G FROM ILC TO GFI RECEPTACLE/LIGHT (1) 1" CONDUIT W/ (2) #10 + (1) #10G FROM ILC TO CHARLES CABINET REV DATE DESCRIPTION BY v ALARM/MISCELLANEOUS CONDUITS 10.(1) 1" CONDUIT FROM ILC TO GENERATOR FOR GEN CONTROLS & ALARMS 11. (1) 1" CONDUIT FROM ILC TO EQUIPMENT CABINET FOR GEN & ILC ALARMS 0_ FPk'TH�JOF G�� z O JOHN A. DAUGHTREY III C/) Lic. No.0402052122 �� 06/10/2020 w� w LL O ZONAL rr w w z_ 0 z w w w Lu w w w m Know what's Cbeow, Call before you dig. w w CI) JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 CONDUIT ROUTING PLAN E=2 NOTE: PANEL SCHEDULE AND SINGLE LINE DIAGRAM REPRESENT A SITE WITH A NEW GE POWER PLANT, 30 KW DIESEL GENERATOR, AND TWO SOURCE ILC (THREE SOURCE ILC OPTIONAL AS NEEDED). ADJUST AS NECESSARY PER LOCAL SITE CONDITIONS TO UTILITY TRANSFORMER I,v'I SERVICE DISCONNECT/ FUSED SWITCH CAM LOCK (OPTIONAL) VERIZON WIRELESS ILC CABINET WITH 2P/200A UTILITY BREAKER AND OPTIONAL 2P/200A CAM LOCK BREAKER MECHANICALLY INTERLOCKED WITH WALKING BEAM TRANSFER SWITCH AND 30 POSITION LOAD CENTER 3-#3/0 AWI #6 AWG EG 2" CONDUIT (130 LF MAX) UTILITY METER )200A N E 200A ILC L C \ 20DA / 200A INTEGRATED LOAD CENTER 4 AWG MBJ 4 AWG GEC 3-#1/0 AWG 6 AWG EG 1-1/2" CONDUIT (185 LF MAX) 1" CONDUIT FOR GEN CONTROLS & ALARMS GFCI 3-#12 AWG RECPT. #12 AWG EG 1" CONDUIT LIGHT GEN MAIN DISCONNECT/ FUSED SWITCH 150A rGE 0 4-#12 AWG,1-#12 AWG EG, 1" CONDUIT (FOR GEN HEATER & BATT. CHARGER) IT FOR GEN & ILC ALARMS 8-#10 AWG, 1-#10 AWG EG, IN (4) 1" CONDUIT ROUTE CONDUIT ABOVE GROUND SECURED TO EQUIPMENT FRAME PRIMARY CABINET LOAD CALCULATION LOAD AMPS PROPOSED LOAD: 148.0 TOTAL DEMAND: 148.0 VOLTAGE: 120/240V SINGLE PHASE 3W 200A VERIZON WIRELESS 30KW DIESEL GENERATOR 3OKW 120/240 V, DIESEL GENERATOR WITH 150A MAIN BREAKER. GENERATOR IS IN A NEMA 3R ENCLOSURE. SUPPLIED WITH 150OW 120V BLOCK HEATER. NOTE: THE GENERATOR USED IN CONJUNCTION WITH A 2-POLE ILC WITH A SOLID NEUTRAL IS NOT A SEPARATELY DERIVED SYSTEM. AS SUCH, DO NOT BOND THE NEUTRAL TO GROUND AT THE GENERATOR 6-#6 AWG (3 PAIRS) #6 AWG EG (1) 1-1/2" LMFC 6-#6 AWG (3 PAIRS) #6 AWG EG (1) 1-1/2" LMFC ELECTRICAL SINGLE LINE DIAGRAM NOTES: 1. ALL EQUIPMENT SHALL BE NEMA 3R RATED. 2. ALL EQUIPMENT SHALL BE LIGHTNING PROTECTED IN ACCORDANCE WITH TIA-222-G AND VERIZON WIRELESS STANDARDS. 3. CONDUCTOR SIZES AND DISTANCES HAVE BEEN SIZED FOR 3% MAX VOLTAGE DROP (TOTAL SYSTEM VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST DEMAND SHALL NOT EXCEED 5%). 4. WIRE SIZING AND MAXIMUM DISTANCE FROM GENERATOR TO ILC ASSUMES POWER FACTOR OF 0.9. 5. BELOW GRADE CONDUIT SHALL BE SCHEDULE 80 PVC. ABOVE GRADE CONDUIT SHALL BE GALVANIZED RIGID CONDUIT. BELOW GRADE PVC CONDUIT SHALL TRANSITION TO GRC PRIOR TO RISING ABOVE GRADE. ALL BENDS SHALL HAVE A MINIMUM 24" RADIUS. ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. VERIFY CONDUIT TYPE WITH LOCAL CONSTRUCTION MANAGER AND ADJUST IF NECESSARY. ALL CONDUIT SHALL MEET NEC, STATE, AND LOCAL CODE REQUIREMENTS AS REQUIRED. OVP-6 OVP-6 i NEEDED) MODELNUMBE VZW ILC ASCO D300L SERIES NAMEL RATED 240 120 VOLTS PHASE/WIRE: 1 1 3 VOLTAGE: MAIN BUS KEY DOOR 200 AMPS 200 YES BREAKER: RATING: LATCH: NEUTRAL MOUNT: SURFACE YES HENGED DOOR: YES BAR: ENCLOSURE NEMA 3R AIC: 65K TYPE: BUS AMPS BUS AMPS USAGE USAGE POS LOAD POLES AMPS L1 L2 AMPS POLES LOAD POS FACTOR FACTOR L1 L2 L1 L2 1 1 18 18 1 2 RECTIFIER 2 30A 30A 2 FUTURE RECTIFIER 3 1 18 18 1 4 5 1 18 18 1 6 RECTIFIER 2 30A 30A 2 FUTURE 7 1 18 RECTIFIER 18 1 8 9 1 18 10 RECTIFIER 2 30A 11 1 18 12 13 1 18 14 RECTIFIER 2 30A 15 1 18 16 GFI RECEPT. 17 1.25 16 1 20A 18 LIGHT 19 1 16 BLOCK HEATER 1 20A 20 21 1 16 BATT. CHARGER 1 20A 22 23 1 24 UPS RECEPT 1 30A 24 25 26 27 28 29 30 104 112 :SUB TOTAL AMPS SUB TOTAL AMPS: 36 36 FACTORED TOTAL 140 148 AMPS: NOTES: 1. ALL CONDUCTORS ARE TYPE THWN (75-C) COPPER. 2. MAXIMUM LENGTH OF RUN FOR RECTIFIER CIRCUITS IS 50FT. 3. ASCO INTEGRATED LOAD CENTER INCLUDES 200 AMP MAIN DISCONNECT AND TRANSFER SWITCH FOR PORTABLE OR PERMANENT GENERATOR. 4. RECTIFIER LOADS ARE CONSIDERED TO BE NON -CONTINUOUS. 5. IF ADDITIONAL FUTURE LOADS ARE ADDED WHICH CAUSE TOTAL DEMAND TO EXCEED GENERATOR BREAKER SIZE, BACKUP POWER SYSTEM SHALL BE EVALUATED AND UPGRADED AS NECESSARY. FIBER HANDHOLE/ MEET -ME POINT AT ROW (1) 2" CONDUIT FOR DARK FIBER * AND (1) 2" CONDUIT FOR EBH IF NEEDED ** PANEL SCHEDULE (1) 2" CONDUIT (FOR DARK FIBER OR EBH AS NEEDED) VZW FIBER HANDHOLE (OR JUNCTION BOX ON COMMON USE UTILITY FRAME) IN COMPOUND (1) 2" CONDUIT (FOR EBH IF NEEDED) FIBER SINGLE LINE DIAGRAM VZW EQUIPMENT FRAME TERMINATION POINT (18"X18" FIBER JUNCTION BOX FOR DARK FIBER OR CHARLES CABINET AS NEEDED FOR EBH) EBH DEMARC (IF REQUIRED, VERIFY REQUIREMENTS WITH EBH PROVIDER) NOTES: * ADD (1) ADDITIONAL 2" CONDUIT FOR DARK FIBER (2 TOTAL) IF REQUIRED BY LOCAL MARKET FACILITIES, VERIFY PRIOR TO CONSTRUCTION. (ADD 2 PULL STRINGS TO EACH CONDUIT) ** VERIFY EBH REQUIREMENTS WITH TELCO PROVIDER PRIOR TO CONSTRUCTION. (ADD 2 PULL STRINGS TO EACH CONDUIT) (1) 2" RGC STRAIGHT RUN AT GRADE (CLAMP TO EQUIPMENT FRAME POSTS), TRANSITION TO 2" LMFC AT EACH FOR EQUIPMENT CABINET CONNECTIONS PRIMARY CABINET 1-1/2" LMFC FOR FIBER AND ALARM (SHIELDED CAT 5) AS NEEDED TM CE LLJ z TOTALLY COMMMEDDo z Lu NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 J U verizon Q 1831 RADY COURT RICHMOND, VA 23222 Q I I WILD TURKEY � I I WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 Lu ALBEMARLE COUNTY 11 REVISIONS 6 06/10/20 REVISED CT 0 m Q 5 04/20/20 REVISED CCC U LLJ m 4 03/09/20 REVISED PJP Z C `5 3 02/24/20 REVISED PJP Cn W 2 12/04/19 REVISED CCC 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD USPRELIMINARY CD US REV I DATE I DESCRIPTION I BY LT H OF G 2 z Q JOHN A. DAUGHTREY III Lie. No.0402052122 C/D�� 06/10/2020 4 LL /ONAL OVP-6 I LU � Lu LLJ z JOHN A. DAUGHTREY III, P.E. 0 VA PROFESSIONAL ENGINEER LIC. #052122 z Lu Ji PANEL SCHEDULE w & ONE -LINE cn (DIESEL OPTION) m Lu m Z E=3 Lu Lu ELECTRICAL NOTES 1. SUBMITTAL OF BID INDICATES THAT THE CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED UNDER THIS CONTRACT. 2. CONTRACTOR SHALL PERFORM ALL VERIFICATIONS, OBSERVATION TESTS, AND EXAMINATION WORK PRIOR TO ORDERING OF ANY EQUIPMENT AND THE ACTUAL CONSTRUCTION. CONTRACTOR SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE PROJECT MANAGER LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 3. VERIFY HEIGHTS WITH PROJECT MANAGER PRIOR TO INSTALLATION. 4. THESE PLANS ARE DIAGRAMMATIC ONLY, FOLLOW AS CLOSELY AS POSSIBLE. 5. CONTRACTOR SHALL COORDINATE ALL WORK BETWEEN TRADES AND ALL OTHER SCHEDULING AND PROVISIONARY CIRCUMSTANCES SURROUNDING THE PROJECT. 6. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION CONSTRUCTION TOOLS, TRANSPORTATION, ETC., FOR COMPLETE AND FUNCTIONALLY OPERATING SYSTEMS ENERGIZED AND READY FOR USE THROUGHOUT AS INDICATED ON DRAWINGS, AS SPECIFIED HEREIN AND/OR AS OTHERWISE REQUIRED. 7. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST GRADE AND OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS OR GROUP OF EQUIPMENT. ELECTRICAL MATERIALS SHALL BE LISTED AND APPROVED BY UNDERWRITER'S LABORATORIES AND SHALL BEAR THE INSPECTION LABEL "J" WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH APPROVAL OF ALL GOVERNING BODIES HAVING JURISDICTION OVER THE CONSTRUCTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH ALL CURRENT APPLICABLE STANDARDS ESTABLISHED BY ANSI, NEMA AND NBFU. ALL MATERIALS AND EQUIPMENT SHALL BE APPROVED FOR THEIR INTENDED USE AND LOCATION. 8. ALL WORK SHALL COMPLY WITH ALL APPLICABLE GOVERNING STATE, COUNTY AND CITY CODES AND OSHA, NFPA, NEC & ASHRAE REQUIREMENTS. 9. ENTIRE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB ACCEPTANCE. ALL WORK, MATERIAL AND EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE CONTRACTOR. 10. PROPERLY SEAL ALL PENETRATIONS. PROVIDE UL LISTED FIRE -STOPS WHERE PENETRATIONS ARE MADE THROUGH FIRE -RATED ASSEMBLIES. WATER -TIGHT USING SILICONE SEALANT. 11. DELIVER ALL BROCHURES, OPERATING MANUALS, CATALOGS AND SHOP DRAWINGS TO THE PROJECT MANAGER AT JOB COMPLETION. PROVIDE MAINTENANCE MANUALS FOR MECHANICAL EQUIPMENT. AFFIX MAINTENANCE LABELS TO MECHANICAL EQUIPMENT. CHARLES CUBE HOFFMAN BOX R J -0-6- ILC PROPOSED (1) 2"0 SCH. 40 PVC CONDUIT W/ (3) #3/0 + (1) #6G FOR ELECTRIC SERVICE FROM METER TO ILC (23' LONG) 12. ALL CONDUCTORS SHALL BE COPPER. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG., UNLESS OTHERWISE NOTED. CONDUCTORS SHALL BE TYPE THWN, RATED IN ACCORDANCE WITH NEC 110-14(C). 13. ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THE MAXIMUM INTERRUPTING CURRENT TO WHICH THEY MAY BE SUBJECTED. 14. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE; ARTICLES 250 & 810 AND THE UTILITY COMPANY STANDARDS. 15. CONDUIT: A. RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS, IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR. RIGID CONDUIT IN CONTACT WITH EARTH SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP PROCESS NO. 3. B. ELECTRICAL METALLIC TUBING SHALL HAVE U.L. LABEL, FITTINGS SHALL BE GLAND RING COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS. C. LIQUID -TIGHT FLEXIBLE METAL CONDUIT SHALL BE U.L. LISTED AND SHALL BE USED AT FINAL CONNECTIONS TO MECHANICAL EQUIPMENT & RECTIFIERS AND WHERE PERMITTED BY CODE. ALL CONDUIT IN EXCESS OF SIX FEET IN LENGTH SHALL CONTAIN A FULL-SIZE GROUND CONDUCTOR. D. CONDUIT RUNS SHALL BE SURFACE MOUNTED ON CEILINGS OR WALLS UNLESS NOTED OTHERWISE. ALL CONDUIT SHALL RUN PARALLEL OR PERPENDICULAR TO WALLS, FLOOR, CEILING, OR BEAMS. VERIFY EXACT ROUTING OF ALL EXPOSED CONDUIT WITH THE PROJECT MANAGER PRIOR TO INSTALLING. E. PVC CONDUIT MAY BE PROVIDED ONLY WHERE SHOWN, OR IN UNDERGROUND INSTALLATIONS. PROVIDE UV -RESISTANT CONDUIT WHERE EXPOSED TO THE ATMOSPHERE. PROVIDE GROUND CONDUCTOR IN ALL PVC RUNS; EXCEPT WHERE PERMITTED BY CODE TO OMIT. 17. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED WITH PERMANENT ENGRAVED PLASTIC LABELS. BACKGROUND SHALL BE BLACK WITH WHITE LETTERS; EXCEPT AS REQUIRED BY CODE TO FOLLOW A DIFFERENT SCHEME. PROPOSED 2 GANG METER BANK PROPOSED SQUARE D SINGLE PHASE FEED THROUGH PANEL RATED 120/24OV, 200 AMP DISCONNECT MODEL # Q01816M20OFTRB OR EQUIVALENT AND PROPOSED 20A GFCI RECEPTACLE (CONTRACTOR TO PROVIDE FAULT PROTECTION GREATER THAN INCOMING FAULT CURRENT FROM POWER GRID) PROPOSED UTILITY H-FRAME INCOMING 120/24OV, 1� ELECTRICAL SERVICE FROM POWER COMPANY (BY OTHERS) PROPOSED (1) 1" SCH. 40 PVC CONDUIT W/ (2) #6 + (1) #10G FROM CHARLES CUBE TO MESA DISCONNECT (25' LONG) 0 0 PROPOSED 120/240v, 1PHASE, 200 AMP UTILITY METER 18. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL OF POTENTIAL GROUNDING TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECT MANAGER. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUE IS EXCEEDED, NOTIFY THE PROJECT MANAGER FOR FURTHER INSTRUCTION ON METHODS FOR REDUCING THE RESISTANCE VALUE. 19. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. LEGALLY DISPOSE OF ALL REMOVED, UNUSED AND EXCESS MATERIAL GENERATED BY THE WORK OF THIS CONTRACT. DELIVER ITEMS INDICATED ON THE DRAWINGS TO THE OWNER IN GOOD CONDITION. OBTAIN SIGNED RECEIPT UPON DELIVERY. 20. COORDINATE WITH UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE. THE TEMPORARY POWER AND ALL HOOKUP COSTS SHALL BE PAID BY THE CONTRACTOR. 21. VERIFY ALL EXISTING CIRCUITRY PRIOR TO REMOVAL AND NEW WORK. MAINTAIN POWER TO ALL OTHER AREAS & CIRCUITS NOT SCHEDULED FOR REMOVAL. 22. RED LINED AS -BUILT PLANS SHALL BE PROVIDED TO THE CONSTRUCTION MANAGER. 23.INDOOR CONDUCTORS SHALL BE INSTALLED IN EMT UNLESS NOTED OTHERWISE. OUTDOOR CONDUCTORS SHALL BE INSTALLED IN RIGID GALVANIZED STEEL CONDUIT UNLESS NOTED OTHERWISE. 24.NY SMSA TO PROVIDE SURGE SUPPRESSOR FOR TELCO BOARD SERVING NEW EQUIPMENT, THE SURGE SUPPRESSOR TO BE INSTALLED BY CONTRACTOR AND GROUNDED TO MGB. 25. SEAL AROUND PENETRATIONS RESULTING FROM CONDUIT ROUTING WITH FIRE- STOPPING FOAM SEALANT HAVING A UL-LISTED RATING OF 2 HOURS. HAMMER -DRILLING IS NOT PERMITTED. CORE -DRILLING TO BE COORDINATED WITH BUILDING OWNER'S REPRESENTATIVE. 26. PROVIDE (2) FUSES OF SIZE RECOMMENDED BY CONDENSING UNIT MANUFACTURER. 27. PROVIDE SMOKE DETECTOR COMPATIBLE WITH EXISTING BUILDING FIRE ALARM SYSTEM. TIE TO LOCAL ZONE. COORDINATE WITH BUILDING OWNER'S FIRE ALARM SYSTEM CONTRACTOR. PROVIDE SENTROL 449CRT PHOTOELECTRIC SMOKE DETECTOR WITH AUXILIARY RELAY FOE ACU-1 SHUTDOWN. 28. PROVIDE GENERATOR CONNECTOR RECEPTACLE AND ENCLOSED CIRCUIT BREAKER IN LOCATION SUITABLE FOR PORTABLE GENERATOR ACCESS. COORDINATE WITH BUILDING OWNER FOR EXACT LOCATION. PAINT TO MATCH EXISTING WALL COLOR. 29. PROVIDE ALARM TERMINAL CABINET HIGH/LOW ALARMS MOUNTED ON TELCO BOARD. 30. PROVIDE DOOR ALARM CONTACT. PROPOSED 30A DISCONNECT ON POST (1) #2/0 G BOND TO POWER COMPOUND GROUNDING SYSTEM PROPOSED (2) 2" SCH. 40 PVC CONDUIT FOR TELCO SERVICE WITH 1000 LB MULETAPE AND COPPERHEAD TRACER WIRE OUTSIDE TRENCH (31' LONG) ELECTRICAL RISER DIAGRAM AND SERVICE ENTRANCE (SCHEMATIC NTS 1. DUE TO EXISTING UTILITIES IN THE AREA, ALL TRENCHING IS TO BE DUG BY HAND. 2. SITE SHALL BE SCRAPED TO A DEPTH OF 3" MINIMUM TO REMOVE VEGETATIVE MATTER. EXCESS MATERIAL GENERATED FROM SCRAPING ACTIVITIES SHALL BE BECOME THE PROPERTY OF THE CONTRACTOR AND BE DISPOSED OF OFF -SITE. 3. EXCAVATION MATERIAL SHALL BE USED FOR SURFACE GRADING AS NECESSARY; EXCESS MATERIAL SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND BE DISPOSED OF OFF -SITE. 4. CONTRACTOR TO PROVIDE A MINIMUM OF 4" SELECT TOPSOIL BORROW AND SEED TO ALL DISTURBED AREAS TO BE RESTORED WITH VEGETATION. SEED MIX SHALL BE APPROVED BY THE RWSA. 5. DISTURBED AREAS OF THE ACCESS DRIVE SHALL BE RESTORED TO ITS ORIGINAL CROSS-SECTION (BOTH AGGREGATE BASE AND GRAVEL SURFACING) AND APPROVED BY THE RWSA. 6. EXISTING UTILITIES MUST BE PROTECTED DURING CONSTRUCTION OF THE PROPOSED IMPROVEMENTS. PROPOSED MESA CABINET PROPOSED (1) 1" SCH. 40 PVC CONDUIT W/ (2) #6 + (1) #10G FROM DISCONNECT TO MESA SPAN (27' LONG) Know what's below. Call before you dig m LU LU z z w z O Q o- 0 LL z LU 0 D' 0 O LU z 0 C/) LU 0 D_ CI _J Z O C!) Cf) LU LL CL D rT- LU LU z_ 0 z LU TM TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizom' 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 106/10/201 REVISED I CT 5 1 04/20/20 1 REVISED I CCC 4 103/09/201 REVISED I Pip 3 102/24/201 REVISED I Pip 2 112/04/19 1 REVISED I CCC 1 111/18/19 1 FINALS I CCC 0 1 10/30/19 1 PRELIMINARY CD I US REV I DATE DESCRIPTION I BY [ H Or G% o ,A JOHN A. DAUGHTREY III „o Lie, No. 0402052122 4L, �0 06/10/2020 _)ATAI JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 w ELECTRICAL RISER J DIAGRAM & w SERVICE ENTRANCE SCHEMATIC D' LU m z LU LU co E=4 GROUNDING NOTES: NOTE: CONNECT ALL H—FRAME MOUNTED EQUIPMENT TO GROUND BAR TM 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUNDING CONNECTIONS TO GROUND RODS, GROUND RING WIRE, TOWER BASE AND FENCE POSTS SHALL BE EXOTHERMIC ("CADWELDS") UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZING PAINT. 5. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO —HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET) CLEAN GROUND BAR TO SHINY METAL. AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 6. GROUND COAXIAL CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 7. ROUTE GROUNDING CONDUCTORS THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 12" RADIUS. 8. INSTALL #2 AWG GREEN —INSULATED STRANDED WIRE FOR ABOVE GRADE GROUNDING AND #2 TINNED SOLID COPPER WIRE FOR BELOW GRADE GROUNDING UNLESS OTHERWISE NOTED. 9. REFER TO GROUNDING PLAN FOR GROUND BAR LOCATIONS. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC TYPE ("CADWELDS") TO ANTENNA MOUNTS AND GROUND RING. REMAINING GROUNDING CONNECTIONS SHALL BE COMPRESSION FITTINGS. CONNECTIONS TO GROUND BARS SHALL BE MADE WITH TWO —HOLE LUGS. 10. THE GROUND ELECTRODE SYSTEM SHALL CONSIST OF DRIVEN GROUND RODS POSITION ACCORDING TO GROUNDING PLAN. THE GROUND RODS SHALL BE 5/8"X10'-0" COPPER CLAD STEEL INTERCONNECTED WITH #2 TINNED SOLID COPPER WIRE BURIED 36" BELOW GRADE. BURY GROUND RODS A MAXIMUM OF 15' APART, AND A MINIMUM OF 8' APART. 11.IF ROCK IS ENCOUNTERED GROUND RODS SHALL BE PLACED AT AN OBLIQUE ANGLE NOT TO EXCEED 45'. 12. EXOTHERMIC WELDS SHALL BE MADE IN ACCORDANCE WITH ERICO PRODUCTS BULLETIN A —AT. 13. CONSTRUCTION OF GROUND RING AND CONNECTIONS TO EXISTING GROUND RING SYSTEM SHALL BE DOCUMENTED WITH PHOTOGRAPHS PRIOR TO BACKFILLING SITE. PROVIDE PHOTOS TO THE VERIZON CONSTRUCTION MANAGER. 14. ALL GROUND LEADS EXCEPT THOSE TO THE EQUIPMENT ARE TO BE #2 TINNED SOLID COPPER WIRE. ALL EXTERIOR GROUND BARS TINNED COPPER. 15. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR—SHIELD (TM OF JET LUBE INC.). PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR—SHIELD OR EQUAL. 16. ENGAGE AN INDEPENDENT ELECTRICAL TESTING FIRM TO TEST AND VERIFY THAT IMPEDANCE DOES NOT EXCEED FIVE OHMS TO GROUND BY MEANS OF "FALL OF POTENTIAL TEST". TEST SHALL BE WITNESSED BY A VERIZON REPRESENTATIVE, AND RECORDED ON THE "GROUND RESISTANCE TEST" FORM. 17. WHERE BARE COPPER GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO GROUND RING, INSTALL WIRE IN 3/4" PVC SLEEVE, FROM 1' BELOW GRADE AND SEAL TOP WITH SILICONE MATERIAL. 18. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI —OXIDIZATION PAINT. 19. ANY SITE WHERE THE EQUIPMENT (BTS, CABLE BRIDGE, PPC, GENERATOR, ETC.) IS LOCATED WITHIN 6 FEET OF METAL FENCING, THE GROUND RING SHALL BE BONDED TO THE NEAREST FENCE POST USING (3) RUNS OF #2 BARE TINNED COPPER WIRE. GROUNDING LEGEND ® COAXIAL CABLE SHIELD GROUND KIT CONNECTION ■ COMPRESSION FITTING CONNECTION • EXOTHERMIC WELD CONNECTION O 5/8"X10' COPPER —CLAD STEEL GROUND ROD O 5/8"X10' COPPER —CLAD STEEL GROUND ROD WITH INSPECTION WELL PROPOSED GROUND WIRING ------ EXISTING GROUND WIRING ® TINNED COPPER GROUND BAR 1/4"X4"X12" OR 1/4"X4"X20" CGB COLLECTOR GROUND BAR MGB MAIN GROUND BAR ----------- ------ ------ ------ ------ ------ ---------� PROPOSED #2 AWG SOLID BARE TINNED I COPPER WIRE TO GROUND RING (TYP. 2 PROPOSED GROUND ROD PROPOSED #2 AWG SOLID BARE TINNED PER GROUND BAR, 1 PER H—FRAME POST) INSPECTION WELL (TYP. OF 4) COPPER WIRE EQUIPMENT GROUND RING 36" BELOW GRADE. SEE SHEET G-2 FOR MORE DETAILS. 0�0 0 0 0 0 0 0�ca 0 0-0-0-0 1 •pe z a .a �I PROPOSED VERIZON WIRELESS GROUND BAR v PROPOSED #2 AWG SOLID BARE TINNED o° 0-0 COPPER WIRE 36" BELOW GRADE. CONNECT ° EQUIPMENT GROUND RING TO PROPOSED ° o TOWER GROUND RING. (TYP. OF 2 LOCATIONS) O 4. + _ •S i o o 0 0 0 PROPOSED TOWER GROUND RING PROPOSED 2—GANG METER BANK ----------I---------- b oy� � oHw oHw oHw � oHw \ GROUNDING PLAN PLAN SCALE: 3/15" = 1' 0 0 GRADE z_ CADWELD CONNECTION co (USE TYPE APPROPRIATE TO APPLICATION) (TYP) 7 #2 TINNED SOLID COPPER WIRE GROUND RING COPPER CLAD STEEL GROUND ROD (5/8"0X10'—O" LONG) BELOW FROST LINE TYPICAL GROUND ROD DETAIL NTS m Lu Lu z TOTALLYCOMMITTED. Z Lu NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 ■ U verizonil Q 1831 RADY COURT RICHMOND, VA 23222 Q I I WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 Lu ALBEMARLE COUNTY L REVISIONS 6 06/10/20 REVISED CT 0 m 0 5 04/20/20 REVISED CCC U Lu m 4 03/09/20 REVISED PJP Z 03 02/24/20 REVISED PJP C/) Lu 2 12/04/19 REVISED CCC 0 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US REV I DATE I DESCRIPTION I BY THREADED PVC PIPE CAP GRADE —III H OF CAD WELD _III III-11I— THIS - = LOCATION ONLY ��PIT G� III M < �o� A� �(Q�� �7(� O �/ Lew #2 TINNED M I I Q Z \ _ f aHw �oHW 6" DIA. SCH 40 SOLID COPPER I I PVC PIPE U JOHN A. DAUGHTREY III GROUND WIRE Cf Lie, No. 0402052122 C/D�� Lu 06/10/2020 O �'ONAL 2" DIA. 5/8" DIA. COPPER CLAD SLOTTED HOLE GROUND ROD. TOTAL (TyP) DEPTH IN SOIL TO BE 10' MIN. 3 INSPECTION WELL DETAIL G 1 NTS Lu Lu Z JOHN A. DAUGHTREY III, P.E. 0 VA PROFESSIONAL ENGINEER LIC. #052122 Lu GRAPHIC SCALE 4 0 2 4 8 16 (IN FEET) Lu 3/16 INCH = 1 FOOT J TYPE TA TYPE VN TYPE NC TYPE SS TYPE W TYPE VS GROUNDING P LA N W Lu & DETAILS TYPE VB TYPE PT TYPE GT TYPE GY TYPE GR TYPE GL m Lu CADWELD GROUNDING CONNECTION DETAILS NTS Z m Lu Gl U� MECHANICALLY CONNECT TO TOWER LEG PROPOSED FENCE POST JVLIV VVrr LI\ �111\L IV�ILI\ GROUND RING #2 TINNED SOLID COPPER 36" BELOW GRADE CONNECTING GROUND RINGS MOUNTING BOLT (VARIES J WITH MOUNTING APPLICATION) ®00"0 600 DIRECT BOLT MOUNTING 0 0 0 0 606 0 0 BRACKETS (SUPPLIED ® 60 0 ® 0 0 0 WITH GROUND BAR) ®®a 0®®0�000 0000006000 ® 0 0 0 0 0 0 TINNED COPPER GROUND BAR 0 0 0 0 0 ® 0 0 (HOLE CENTERS TO MATCH NEMA 0 0 0 0 0 0 0 DOUBLE LUG CONFIGURATION) ®0�00 INSULATORS (TO BE USED WHEN THERE IS A HOME RUN ON TOWER) GROUND BAR SCHEDULE TYPE QTY MANUFACTURER PART NO. REMARKS MGB 2 ANDREW UGBKIT-0420—T OR EQUAL CBG 3 ANDREW UGBKIT-0412 OR EQUAL 3 GROUND BAR DETAIL G 2 NTS #2 TINNED SOLID COPPER CADWELD TO ANTENNA MAST GROUND COAXIAL SIGNAL CABLES USING MANUFACTURERS GROUNDING KITS (TYP) GROUNDING RISER DIAGRAM NTS STAINLESS STEEL HARDWARE " TWO HOLE COPPER COMPRESSION TERMINAL GROUNDING GROUNDING BAR CABLE ELEVATION LOCKWASHER / (FTMP) WASHER (TYP) ; NUT (TYP) 1/2"x1 1/2" HEX BOLT (TYP, STAINLESS STEEL) GROUND BAR EXPOSED BARE COPPER TO BE KEPT TO ABSOLUTE MINIMUM, NO GROUNDING INSULATION ALLOWED WITHIN THE CABLE COMPRESSION TERMINAL (TYP) SECTION "A —A" NOTE: 1. "DOUBLING UP" OR "STACKING" OF CONNECTIONS IS NOT PERMITTED. 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. TYPICAL GROUND BAR CONN DETAIL NTS ADJUSTABLE STRAP GROUNDING CLAMP 00 GROUNDING STRAP M 7/16" HOLE 9/16" HEX �-j JACKET TRIM AREA FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 5 � FIGURE 6 GROUNDING LUG 9/16" HEX 15/16" HEX ROUNDING LAMP SLOT FOR ABLE CLAMP STAINLESS STEEL ABLE CLAMP ROUNDING STRAP ASSEMBLY ELECTRICAL TAPE OVER PUTTY TAPE TYPICAL COAX WEATHERPROOFING DETAIL NTS oononcrn ________ PROPOSED PROPOSED #2 TINNED LI 5/8"X10' LONG SOLID COPPER WIRE COPPER CLAD GROUND GROUND RING ROD (TYP OF OC, MAX) TO ANTENNA 3/8" COAX CABLE COAX CABLE GROUNDING CLAMP KIT COPPER GROUNDING CONDUCTOR TO GROUND BAR (TYP) TO EQUIPMENT COAX CABLE GROUNDING DETAIL NTS 1 /2" 0 COAXIAL JUMPER CABLE (TYP, 3'-0" MAXIMUM) COAXIAL CABLE DIN CONNECTOR GROUND WIRE (TYP) SECTOR GROUND BAR TO REFERENCE GROUND VIA MGB COAXIAL CABLE GROUNDING KIT (TYP) COAXIAL CABLE TO BTS ANTENNA GROUNDING DETAIL NTS TM uj z TOTALLY LY COO IMl M 0 IE Do z W NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizon%l z D_ Q 1831 RADY COURT RICHMOND, VA 23222 Q WILD TURKEY WILD TURKEY LANE o CHARLOTTESVILLE, VA 22903 Lu ALBEMARLE COUNTY l REVISIONS 6 06/10/20 REVISED CT 0 m 0 5 04/20/20 REVISED CCC U W m 4 03/09/20 REVISED PJP z 3 02/24/20 REVISED PJP Co W 2 12/04/19 REVISED CCC 0 D_ Q C!) J Z U co W LL m D cz Lu Lu z z Lu W W W uJ LI..I m z W W co 1 1 11/18/191 FINALS CCC 0 110/30/19 1 PRELIMINARY CD US REV I DATE DESCRIPTION BY [ H Or G��� XA v JOHN A. DAUGHTREY III „o Lie, No. 0402052122 06/10/2020 s ' C)NI JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 GROUNDING RISER DIAGRAM & DETAILS G=2 L— C m z 0 i Know what's below. Call before you dig. EROSION & SEDIMENT CONTROL PLAN SCALE: 1" = 10'-0" GRAPHIC SCALE 10 20 (IN FEET) 1 INCH = 10 FEET EXISTING FENCED COMPOUND I >/ (SOIL SUMMARY I HAYEVILLE LOAN PROPOSED CONTOUR (TYP.) 2-7% SLOPES I PROPOSED LIMIT OF DISTURBANCE (APPROX. = 3,335 SF) cr N-1 mi� 7N Lu Lu TOTALLY COMMMEDD. z Lu NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 ■ U verizon'll a_ Q 1831 RADY COURT RICHMOND, VA 23222 I 16�M I I I O I I PROPOSED BLANKET MATTING TREATMENT 1 TS Z (SEE SHEET ES-4 FOR DETAILS) O II PROPOSED TEMPORARY WILD TURKEY I SEEDING (SEE SHEET ES-4 FOR DETAILS) WILD TURKEY LANE LL CHARLOTTESVILLE, VA 22903 TP LU ALBEMARLE COUNTY PROPOSED TREE PROTECTION (SEE SHEET ES-4 FOR DETAILS) EXISTING TREE (TO REMAIN) LEGEND STORM WATER RUNOFF CONSIDERATIONS THE NATURAL DRAINAGE CONDITION FROM THE THE PROPOSED SITE WILL BE MAINTAINED TO THE GREATEST EXTENT POSSIBLE. ALL DRAINAGE FROM THE DISTURBED AREA WILL BE IN SHEET FLOW. THUS SATISFYING MINIMUM STANDARD 19. PROPERTY LINE — SUBJECT PARCEL EXISTING CONTOUR LINE PROPOSED CONTOUR LINE PROPOSED FENCE PROPOSED LEASE AREA PROPOSED LIMITS OF DISTURBANCE PROPOSED SILT FENCE PROPOSED TREE PROTECTION PROPOSED CONSTRUCTION ENTRANCE 1 REVISIONS 6 1 06/10/20 1 REVISED CT cz 0 5 04/20/20 REVISED CCC U LU 4 03/09/20 REVISED PJP Z 3 02/24/20 REVISED PJP LLI 2 12/04/19 REVISED CCC CI J z O 00 W LL O rr n rT- LU LU Z 0 Z LU LLJ J W LLJ m LU m Z LU LU Cl) 1 1 11/18/19 1 FINALS I CCC 1 1 0 1 10/30/19 1 PRELIMINARY CD I US 1 REV I DATE I DESCRIPTION I BY I �o���PtiTH OF Dr�� JOHN A. DAUGHTREY III Lic. No. 0402052122 .� 06/10/2020 Wit JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION & SEDIMENT CONTROL & GRADING PLAN ES-1 TN w TOTALLY COO MM177EDe z w NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 PVI STA: 0+19.89 PVI STA: 0+51.14 PVI ELEV: 673.96 PVI ELEV: 671.96 K: 2.47 K: 3.24 LVC: 14.84 LVC: 13.57 h U-) HIGH PT. STA: 0+12.69 N co N r� N ■ N r1iii HIGH PT ELEV: 673.95 N N N w w w w z verizon, 680 5 o m m > w > m > w 680 J w w a- d Q 1831 RADY COURT o RICHMOND, VA 23222 II I I I I ---------Q -- -- — — — — — — -------------------------------------------------------------------------------- � a LL1 ---------m ------------------- ---------------------------------------------------------------------------- 676 0 676 >LLJ O W Q WILD TURKEY WILD TURKEY LANE ------------------rt--------------------------r-------------------------rt-------------------- o CHARLOTTESVILLE, VA 22903 — o Cd ALBEMARLE COUNTY co I I I I I 672----------- --------------------------------------------------------------------------------------------' -------------------------------- o cn 0 I Q REVISIONS ---------------------------------- — I— I w 6 06/10/20 REVISED CT O 5 04/20/20 REVISED CCC 668 Lu — — — — — — — — -- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — t — — — — — — — — — — — — — — — — — — — — — — — — — — r — — — — — — — — — — — — — — — — — — — — — — — — — 4 03/09/20 REVISED PJP 3 02/24/20 REVISED PJP -1j 2 12/04/19 REVISED CCC — — — — — — — — — -- — — — — — — — — — — — — — — — — — — — — — — — — — — -— — — — — — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — -- — — — — — — — — — — — — — — — — — — — — 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US I I I I I 664 I — ------------------------------------------------�------------------------ — REV DATE DESCRIPTION BY I I I I I I I I I I I I I I I I I I r-------------------------fi— TxoF � ENV i Q 660 Z O JOHN A. DAUGHTREY III O � a Lic. No.0402052122 o+oo ACCESS ROAD PROFILE 1+00 w �o o6i1oi2ozo ww ES-2 0 IO LL w w Z JOHN A. DAUGHTREY III, P.E. (D VA PROFESSIONAL ENGINEER LIC. #052122 z w w J w ACCESS ROAD = PROFILE w z ES=2 w w _ EROSION AND SEDIMENT CONTROL NARRATIVE PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS THE CONSTRUCTION OF A MONOPOLE TOWER, 90' LONG ACCESS ROAD AND FENCED COMPOUND, ALONG WITH ASSOCIATED UTILITIES. THE LEASE AREA OF THE TOWER IS 900 SF.; THE COMPOUND AREA IS 750 SF.; THE TOTAL DISTURBED AREA IS 3,335 S.F. OF WHICH 1,840 S.F. WILL BE COVERED WITH A GRAVEL SURFACE AND THE REMAINING 1,495 S.F. WILL BE MANAGED TURF. CONSTRUCTION SEQUENCE GENERAL EROSION AND SEDIMENT CONTROL NOTES: AT LEAST 7 DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, THE OWNER/OPERATOR SHALL INVITE 1 THE OWNER/DEVELOPER MUST NOTIFY THE ALBEMARLE COUNTY AT LEAST 24 HOURS PRIOR TO THE START OF ALL CONTRACTORS INVOLVED IN THOSE ACTIVITIES, THE LANDOWNER, ALL APPROPRIATE MUNICIPAL OFFICIALS, BEFORE S 2. E STARTING ANY EARTH DISTURBANCE ACTIVITIES, ALL OWNER/DEVELOPER CONSTRUCTION IN ACCORDANCE WITH APPLICABLE ALBEMARLE COUNTY ORDINANCES AND POLICIES. MEETING. ALSO, AT LEAST 3 WORKING DAYS BEFOR THE EROSION AND SEDIMENT CONTROL PLAN EAND THE CONSERVATION DISTRICT TO AN ON -SITE COUNTY PERSONNEL OWNER DEVELOPER GRANTS THE RIGHT -OF -ENTRY ON TO THIS PROPERTY TO THE DESIGNATED ALBEMARLE ONNEL FOR THE PURPOSE OF INSPECTING AND MONITORING FOR COMPLIANCE WITH TITLE 10.01, VIRGINIA CONTRACTORS INVOLVED IN THOSE ACTIVITIES SHALL NOTIFY THE VIRGINIA ONE CALL SYSTEM MISS UTILITY" INCORPORATED AT 811 FOR BURIED UTILITIES LOCATIONS. CHAPTER 5, ARTICLE 4 OF THE CODE OF VIRGINIA, EROSION AND SEDIMENT CONTROL LAW AND THE DESIGN AND CONSTRUCTION STANDARDS MANUAL SECTION 750.04. EXISTING SITE CONDITIONS EROSION AND SEDIMENT BMPS MUST BE CONSTRUCTED, STABILIZED, AND FUNCTIONAL BEFORE SITE 3. ALL EROSION CONTROL MEASURES SHOWN ON THE APPROVED PLAN MUST BE IN PLACE AND INSPECTED AND THE SITE HAS (2) EXISTING MONOPOLES AND ASSOCIATED FACILITIES. THE PROPOSED POLE AND COMPOUND WILL JUST TO THE DISTURBANCE BEGINS WITHIN THE TRIBUTARY AREAS OF THOSE BMPS. APPROVED BY THE DEPARTMENT PF PUBLIC WORKS PRIOR TO CLEARING, STRIPPING OF TOPSOIL OR GRADING. SOUTH WEST. THE LAND SLOPES AT DOWN 10% FROM AN EXISTING ACCESS ROAD TO THE PROPOSED LOCATION BEFORE 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE KEPT ON THE SITE DROPPING OF AT A RATE OF 62% DOWN TO ROCKFISH GAP TURNPIKE. OUR PROPOSED COMPOUND SITS ON TOP OF A SMALL ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SEQUENCE. EACH AT ALL TIMES. 25' RIDGE ABOVE ROCKFISH GAP TURNPIKE. THE ACCESS ROAD AND COMPOUND IS PRIMARILY OPEN SPACE WITH FEW TREES. STAGE SHALL BE COMPLETED BEFORE ANY FOLLOWING STAGE IS INITIATED. CLEARING AND GRUBBING SHALL BE 5. THE DEVELOPER/DEVELOPERS'S REPRESENTATIVE IS RESPONSIBLE FOR THE INSTALLATION OF ANY ADDITIONAL ADJACENT AREAS THE ADJACENT AREAS ARE MAINLY UNDEVELOPED WOODLANDS, AGRICULTURAL FIELDS AND SINGLE FAMILY RESIDENCES. OFF -SITE AREAS ALL ORGANIC MATERIAL, TREE VEGETATION, ROCKS GREATER THAN 12" IN ANY DIRECTION AND EXCESS CUT MATERIAL TO BE HAULED OFF SITE. CONTRACTOR TO ENSURE MATERIAL IS DISPOSED OF AT AN APPROVED AND PERMITTED SOIL DISPOSAL LOCATION. SOILS 368HAYEVILLE LOAM - 2% TO 7% SLOPES - HYDROLOGIC SOIL GROUP B 36C HAYEVILLE LOAM - 7% TO 15% SLOPES - HYDROLOGIC SOIL GROUP B CRITICAL AREAS THE PROPOSED PROJECT WILL NOT CREATE ANY CRITICAL AREAS ESC MEASURES - STRUCTURAL PRACTICES STRUCTURAL MEASURES TO BE USED ON THE SITE INCLUDE SILT FENCE (VE&SCH SPEC. 3.05), CONSTRUCTION ENTRANCE (VE&SCH SPEC. 3.02), CONSTRUCTION ROAD STABILIZATION (VE&SCH SPEC. 3.03), TEMPORARY STOCK PILE (VE&SCH SPEC. 3.30) AND CONCRETE WASHOUT. ALL MEASURES SELECTED ARE STANDARD ESC ITEMS FOR THIS APPLICATION. ANY DISTURBED AREA DENUDED FOR SEVEN DAYS THAT IS NOT IN ACTIVE WORK AREA TO BE TEMPORARILY SEEDED. ESC MEASURES - VEGETATIVE PRACTICES VEGETATION PRACTICES INCLUDE TEMPORARY AND PERMANENT SEEDING (VE&SCH SPEC. 3.31 & 3.32) PERMANENT STABILIZATION 1. UNTIL AN ADEQUATE ROOT SYSTEM IS ESTABLISHED AND IN THE ABSENCE OF ADEQUATE RAINFALL, SODDING (OR WHATEVER VEGETATION IS USED) SHALL BE IRRIGATED AS OFTEN AS NECESSARY TO MAINTAIN MOIST SOIL TO A DEPTH OF 4 INCHES. IN GENERAL, WATERING SHALL BE PERFORMED IN ACCORDANCE WITH THE VESCH. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE STABILIZED WITH PERMANENT SEEDING IMMEDIATELY FOLLOWING FINISHED GRADING. SEEDING SHALL BE DONE WITH KENTUCKY 31 TALL FESCUE ACCORDING TO STD. AND SPEC. 3.32, PERMANENT SEEDING, OF THE HANDBOOK. EROSION CONTROL BLANKETS WILL BE INSTALLED OVER FILL SLOPES WHICH HAVE BEEN BROUGHT TO FINAL GRADE AND HAVE BEEN SEEDED TO PROTECT THE SLOPES PROPERLY. MULCH (STRAW OR FIBER) WILL BE USED ON RELATIVELY FLAT AREAS. IN ALL SEEDING OPERATIONS, SEED FERTILIZER AND LIME WILL BE APPLIED PRIOR TO MULCHING. FINAL STABILIZATION IS CONSIDERED COMPLETED WHEN 100% OF THE DISTURBED SOIL SURFACE IS UNIFORMLY COVERED IN PERMANENT VEGETATION WITH A DENSITY OF 70% OR GREATER. STORM WATER RUNOFF CONSIDERATIONS THE NATURAL DRAINAGE CONDITION FROM THE THE PROPOSED SITE WILL BE MAINTAINED TO THE GREATEST EXTENT POSSIBLE. ALL DRAINAGE FROM THE DISTURBED AREA WILL BE IN SHEET FLOW. THUS SATISFYING MINIMUM STANDARD 19. LIMITED ONLY TO THOSE AREAS DESCRIBED IN EACH STAGE. 1. INSTALL ROCK CONSTRUCTION ENTRANCE AND ALL PERIMETER BMP'S AS SHOWN ON THE PLANS. 2. CLEAR TREES AND LIMBS FOR FULL WIDTH OF EASEMENT AND LEASE AREA, GROUND TO SKY. 3. STRIP TOPSOIL FOR THE ACCESS DRIVE AND STORE AT DESIGNATED LOCATIONS AS SHOWN ON THE PLANS OR LOCATION AS AGREED UPON WITH THE CONSTRUCTION MANAGER. 4. BEGIN GRADING AND INSTALL GRAVEL, ROADSIDE DITCHES, AND CULVERTS WITH OUTLET PROTECTION. 5. STRIP TOPSOIL ACROSS COMPOUND AND STORE AT DESIGNATED LOCATIONS AS SHOWN ON THE PLANS OR LOCATION AS AGREED UPON WITH THE CONSTRUCTION MANAGER. 6. GRADE COMPOUND SITE AND INSTALL GRAVEL. IMMEDIATELY STABILIZE FILL AND CUT SLOPES WITH EROSION CONTROL MATTING OR ROCK. 7. ONCE CONSTRUCTION OF COMPOUND AND ACCESS DRIVE IS COMPLETE, BEGIN CONSTRUCTION OF TOWER AND ASSOCIATED FACILITIES AND UTILITIES AS SHOWN ON THE DRAWINGS. 8. IF CONSTRUCTION IS TERMINATED OR SUSPENDED PRIOR TO CONSTRUCTION COMPLETION, ALL EXPOSED SOIL AREAS SHALL BE SEEDED WITH TEMPORARY SEEDING AND MULCHED IMMEDIATELY. 9. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN ALL SEDIMENT AND EROSION CONTROL FACILITIES IN EFFECTIVE WORKING ORDER DURING CONSTRUCTION AND UNTIL ALL EXPOSED SOIL AREAS HAVE BEEN STABILIZED. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE, THE 0/RP SHALL STABILIZE ANY AREAS DISTURBED BY THE ACTIVITIES. DURING NON -GERMINATING PERIODS, MULCH MUST BE APPLIED AT THE SPECIFIED RATES. DISTURBED AREAS WHICH ARE NOT AT FINISHED GRADE AND WHICH WILL BE REDISTURBED WITHIN 1 YEAR MUST BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY VEGETATIVE STABILIZATION SPECIFICATIONS. DISTURBED AREAS WHICH ARE AT FINISHED GRADE OR WHICH WILL NOT BE REDISTURBED WITHIN 1 YEAR MUST BE STABILIZED IN ACCORDANCE WITH THE PERMANENT VEGETATIVE STABILIZATION SPECIFICATIONS. AN AREA SHALL BE CONSIDERED TO HAVE ACHIEVED FINAL STABILIZATION WHEN IT HAS A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR OTHER PERMANENT NON -VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED SURFACE EROSION AND SUBSURFACE CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER MOVEMENTS. AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND SEDIMENT BMPS MUST BE REMOVED. AREAS DISTURBED DURING REMOVAL OF THE BMPS MUST BE STABILIZED IMMEDIATELY. EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE ALBEMARLE COUNTY. 6. ALL DISTRIBUTED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL COMPLETE AND ADEQUATE STABILIZATION IS ACHIEVED. 7. WATER MUST BE PUMPED INTO AN APPROVED FILTERING DEVICE DURING DEWATERING OPERATIONS. 8. ALL EROSION AND SEDIMENT CONTROL PRACTICES MUST BE CONSTRUCTED AND MAINTAINED ACCORDING TO THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND THE VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS AND TO ALBEMARLE COUNTY DESIGN AND CONSTRUCTION STANDARDS MANUAL. THE DEVELOPER/DEVELOPER'S REPRESENTATIVE WILL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL PRACTICES AT ALL TIMES. 9. THE DEVELOPERS/ DEVELOPER'S REPRESENTATIVE SHALL INSPECT ALL EROSION AND SEDIMENT CONTROL MEASURES DAILY AND AFTER EACH SIGNIFICANT RAINFALL THE FOLLOWING ITEMS WILL BE CHECKED IN PARTICULAR: a. SILT FENCE BARRIERS WILL BE CHECKED REGULARLY FOR UNDERMINING OR DETERIORATION OF THE FABRIC. SEDIMENT SHALL BE REMOVED WHEN THE LEVEL OF SEDIMENT DEPOSITION REACHES HALF WAY TO THE TOP OF THE BARRIER. b. SEEDED AREAS WILL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RE -SEEDED AS NEEDED. 10. SEDIMENT TRAPPING MEASURES WILL BE INSTALLED AS A FIRST STEP IN GRADING AND WILL BE SEEDED AND MULCHED IMMEDIATELY FOLLOWING INSTALLATION. 11. PERMANENT SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZED SHALL BE APPLIED WITH IN SEVEN (7) DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN UNDISTURBED FOR LONGER THAN FOURTEEN (14) DAYS. SEEDING AND SELECTION OF THE SEED MIXTURE SHALL BE IN ACCORDANCE WITH VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK STANDARD AND SPECIFICATION 3.32. ROADS AND PARKING AREAS SHALL BE STABILIZED WITH SEVEN (7) DAYS AFTER FINAL GRADE IS REACHED. 12. ELECTRIC POWER, TELEPHONE, CABLE T.V. AND GAS SUPPLY TRENCHES SHALL BE COMPACTED, SEEDED AND MULCHED WITHIN FIVE DAYS AFTER BACKFILL 13. ALL TEMPORARY EARTH BERMS, DIVERSIONS AND SILT DAMS SHALL BE MULCHED WITHIN FIVE DAYS AFTER GRADING. STRAW OR HAY MULCH IS REQUIRED. 14. DURING CONSTRUCTION, ALL STORM SEWER INLETS SHALL BE PROTECTED BY INLET PROTECTION MAINTAINED AN MODIFIED DURING CONSTRUCTION AS REQUIRED. 15. AT THE COMPLETION OF ANY PROJECT CONSTRUCTION AND PRIOR TO BOND RELEASE, ALL TEMPORARY SEDIMENT CONTROL MEASURES SHALL BE REMOVED. 16. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES WILL BE REMOVED WITHIN 30 DAYS AFTER ADEQUATE SITE STABILIZATION AND AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, AS AUTHORIZED BY THE ALBEMARLE COUNTY INSPECTORS. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES WILL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 17. WHEN SEDIMENT IS TRANSPORTED ONTO A PAVED ROAD SURFACE, THE ROAD WILL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT WILL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND MANAGEMENT STRATEGIES TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING WILL BE ALLOWED ONLY AFTER 1. CONSTRUCTION WILL BE SEQUENCED SO THAT GRADING OPERATIONS CAN BEGIN AND END AS QUICKLY AS POSSIBLE. MAINTENANCE SEDIMENT IS REMOVED IN THIS MANNER. 1. TEMPORARY SEEDING OR OTHER STABILIZATION WILL FOLLOW IMMEDIATELY AFTER GRADING. SEE VA E&SC HANDBOOK 3.31-B 18. AREAS WHICH ARE NOT TO BE DISTURBED WILL BE CLEARLY MARKED BY FLAGS, SIGNS, ETC. FOR SEEDING SPECIFICATION. 1. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH 19. RPA AND FLOOD PLAIN LIMITS SHALL BE CLEARLY MARKED IN THE FIELD BY FLAGS, SIGNS, ETC. 2. SEASONAL NURSE CROP MAY BE REQUIRED. RUNOFF PRODUCING RAINFALL EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS 20. TREE SAVE AREAS SHALL BE CLEARLY MARKED IN THE FIELD BY ORANGE SAFETY FENCE. APPROPRIATE TREE 3. AREAS WHICH ARE NOT TO BE DISTURBED WILL BE CLEARLY MARKED BY FLAGS, SIGNS, ETC. OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. THE FOLLOWING ITEMS WILL BE CHECKED, PRESERVATIONS SIGNS (WATERPROOF) TO IDENTIFY TREE PRESERVATION AREA SHALL BE LOCATED ON TREE 4. THE JOB SUPERINTENDENT SHALL BE RESPONSIBLE FOR THE INSTALLATION AND MAINTENANCE OF ALL ESC PRACTICES. IN PARTICULAR: PROTECTIONS FENCING (INCLUDES SUPER SILT FENCING) AND SHOULD BE LOCATED ALTERNATE BETWEEN 5. AFTER ACHIEVING ADEQUATE STABILIZATION THE TEMPORARY ESC MEASURES WILL BE CLEANED UP FROM ACCUMULATED ENGLISH AND SPANISH EVERY 30 FEET. SEDIMENT AND REMOVED, ONLY AFTER APPROVAL OF THE JURISDICTION ESC INSPECTOR. 2. THE SILT FENCE BARRIER WILL BE CHECKED REGULARLY FOR UNDERMINING OR DETERIORATION OF THE 21. ORANGE SAFETY FENCE MUST BE INSTALLED AROUND ALL SILT TRAPS AND SEDIMENT BASINS. GENERAL NOTES 1. GENERAL CONTRACTOR MAY RELOCATE OR REVISE EROSION AND SEDIMENT CONTROLS AS DEEMED NECESSARY DURING CONSTRUCTION TO MAINTAIN PROPER SEDIMENT CONTROL. 2. ALL EXISTING UNDERGROUND AND ABOVE GROUND UTILITIES TO BE RELOCATED AS NECESSARY TO ACCOMMODATE THE PROPOSED IMPROVEMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING LOCAL UTILITY COMPANIES PRIOR TO CONSTRUCTION. 3. ALL ONSITE DRAINAGE EASEMENTS INCLUDING STORMWATER/B.M.P. DRAINAGE EASEMENTS MUST BE RECORDED PRIOR TO ISSUANCE OF A BUILDING PERMIT FOR THIS PROJECT. UNDERGROUND UTILITY LINE INSTALLATION: UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: 1. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. 2. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. 3. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. 4. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. 5. DESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. 6. COMPLY WITH APPLICABLE SAFETY REGULATIONS. FABRIC. SEDIMENT SHALL BE REMOVED WHEN THE LEVEL OF SEDIMENT DEPOSITION REACHES HALF WAY TO THE TOP OF THE BARRIER. 3. THE SEEDED AREAS WILL BE CHECKED REGULARLY TO ENSURE THAT A GOOD STAND IS MAINTAINED. AREAS SHOULD BE FERTILIZED AND RE -SEEDED AS NEEDED. 4. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ECS CONTROLS DURING CONSTRUCTION. 5. INSPECTION TO BE CONDUCTED SHALL BE PER CARROLL COUNTY STANDARDS AND REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS. 6. SILT FENCE SHALL BE CHECKED AFTER EACH MAJOR STORM EVENT OR ONCE EVERY FIVE DAYS. SEDIMENT SHALL BE REMOVED AFTER IT BECOMES 113 HEIGHT OF SILT FENCE. 7. ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL WILL BE CONSTRUCTED ACCORDING TO THE STANDARDS AND SPECIFICATIONS OF THE VIRGINIA SEDIMENT AND EROSION CONTROL HANDBOOK, 3RD ED, 1992. GRADING NOTES 1. SOILS USED FOR ROADWAY SUBGRADE MUST BE COMPACTED SO THAT THE MINIMUM DRY DENSITY ACHIEVED EXCEEDS 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY. THE CONTRACTOR MAY ONLY USE CUT MATERIAL AS FILL IF IT CAN BE COMPACTED TO 95% OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY. PROCTOR READING MUST BE INSPECTED AND APPROVED BY A THIRD PARTY DURING ROADWAY CONSTRUCTION. 2. NATIVE TOPSOIL SHALL BE SAVED, STOCKPILED, MULCHED, AND REUSED AS MUCH AS POSSIBLE ON THE SITE. SILTATION FENCE SHALL BE INSTALLED AT THE BASE OF STOCKPILES AT THE DOWNHILL LIMIT TO PROTECT AGAINST EROSION. STOCKPILES WILL BE STABILIZED BY SEEDING AND MULCHING UPON FORMATION OF THE PILES. UPHILL OF THE STOCKPILES, STABILIZED DITCHES AND/OR BERMS WILL BE CONSTRUCTED TO DIVERT STORMWATER RUNOFF AWAY FROM THE PILES. EXCESS CUT SOIL NOT REUSED AS FILL SHALL BE HAULED OFF SITE TO AN APPROVED AND PERMITTED SOIL DISPOSAL SITE AS SOON AS FINAL GRADE HAS BEEN ESTABLISHED. 3. FOR AN EARTH DISTURBANCE ACTIVITY OR ANY STAGE OR PHASE OF AN ACTIVITY TO BE CONSIDERED PERMANENTLY STABILIZED, THE DISTURBED AREAS SHALL BE COVERED BY A MINIMUM UNIFORM 70% PERENNIAL VEGETATIVE COVER OR OTHER PERMANENT NON -VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION AND SUBSURFACE CHARACTERISTICS SUFFICIENT TO RESIST SLIDING AND OTHER MOVEMENTS. 4. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 8 INCHES IN THICKNESS. 5. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR ORGANIC MATERIAL THAT WOULD INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS. ANY ROCK GREATER THAN 12" IN ANY DIRECTION SHOULD BE DISPOSED OF AND NOT USED AS FILL. FILL SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES. 6. PLOW, SCARIFY, BENCH, OR BREAK UP SLOPED SURFACES STEEPER THAN 1 VERTICAL TO 4 HORIZONTAL SO FILL MATERIAL WILL BOND WITH EXISTING MATERIAL. IF FILL EXCEEDS 4' IN HEIGHT FROM TOE TO CREST, FILL MUST BE BENCHED AND KEYED IN. SEE DETAIL 4/ES-7 FOR DETAILS. 7. PLACE SOIL FILL ON SUB -GRADES FREE OF ORGANIC MATERIAL, MUD, FROST, SNOW, OR ICE 8. PLACE BACKFILL AND FILL MATERIALS IN LAYERS NOT MORE THAN 8 INCHES THICK IN LOOSE DEPTH COMPACTED BY HEAVY COMPACTION EQUIPMENT, AND NOT MORE THAN 4 INCHES IN LOOSE DEPTH FOR MATERIAL COMPACTED BY HAND OPERATED TAMPERS. 9. UNDER ACCESS ROADS WITH MARGINAL TO EXCESSIVE SLOPES AND MARGINAL SUBGRADE, CLEAR, GRUB AND SCARIFY ROAD AREA. INSTALL ONE LAYER OF GEO-TEXTILE FABRIC (US 160 NW OR EQUIVALENT) AND PIN TO SUBGRADE. INSTALL BASE LAYER, AND TRACK IN WITH A BULLDOZER OR SHEEPSFOOT ROLLER, INSTALL SURFACE LAYER, DRESS ROAD AS REQUIRED AFTER CONSTRUCTION WITH MOTOR GRADER AND COMPACT WITH A VIBRATORY ROAD ROLLER. HAY BALE AND PLASTIC WASHOUT PIT HAY BALE AND PLASTIC WASHOUT PIT TO BE BUILT ABOVE GRADE. THE PLASTIC LINING SHOULD BE MINIMUM 10 MIL THICKNESS, FREE OF TEARS OR HOLES THAT WOULD ALLOW THE WASHWATER TO ESCAPE. AFTER THE PIT IS USED TO WASH DOWN THE CHUTES OF MULTIPLE READY MIXED TRUCKS AND THE WASHWATER HAS EVAPORATED OR HAS BEEN VACUUMED OFF, THE REMAINING HARDENED SOLIDS CAN BE BROKEN UP AND REMOVED FROM THE PIT. THIS PROCESS MAY DAMAGE THE HAY BALES AND PLASTIC LINING. IF DAMAGE OCCURS, THE PIT WILL NEED TO BE REPAIRED AND RELINED WITH NEW PLASTIC. WHEN THE HARDENED SOLIDS ARE REMOVED FROM THE PIT. THE WASTE MATERIAL MUST BE RECYCLED OR DISPOSED OF AT AN APPROVE WASTE FACILITY. m Lu LIJ z_ 0 z Lu z U J IL CL Q O O Lu Z co Lu n D_ C1 J Z O U) U) Lu IL m D n- Lu Lu z_ 0 z Lu Lu J LJ w Lu U) 0' Lu m Z Lu Lu C/D TM TOTALLY OOOIM1MITTCE0o NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonil 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 06/10/20 REVISED CT 5 04/20/20 REVISED CCC 4 103/09/201 REVISED I Pip 3 1 02/24/201 REVISED I Pip 2 1 12/04/19 1 REVISED I CCC 1 11/18/19 FINALS CCC 0010/30/19 PRELIMINARY CD USPRELIMINARY CD US REV I DATE I DESCRIPTION I BY [ H O O � JOHN A. DAUGHTREY III _0 Lie, No. 0402052122 �O 06/10/2020 1' nA[AI JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION SEDIMENT CONTROL NOTES ES-3 TNt CONSTRUCTION OF A SILT FENCE (WITH WIRE SUPPORT) STONE CONSTRUCTION ENTRANCE TABLE 3.32-C 1. SET POSTS AND EXCAVATE A 4" X47 2. STAPLE WIRE FENCING TO THE POSTS. SITE SPECIFIC SEEDING MIXTURES TRENCH UPSLOPE ALONG THE LINE 70' MIN. EXISTING FOR APPALACHIAN/MOUNTAIN AREA OF POSTS. PAVEMENT Total Lbs. A3 rs:1 Minimum Care Lawn Per Acre FILTER CLDTM d MOUNTABLE HERM - Commercial or Residential 200-250 lbs. MIN. q (OPTIONAL) - Kentucky 31 or Turf -Type Tall Fescue 90-100% j_ l Ryegrass * 0-10% - ImprovKentucky / SIDE ELEVATION - Kentuc Bluegrass 0-10% L ( I II — II ` �I EXISTING GROUND High -Maintenance Lawn I h ]III J� `I1 �I ]III -i//— 70' NIN. Minimum five of three (3) up to (5) varieties WASHRACK 10' MIN' of bluegrass from approved list for use in Virginia. 125 lbs. (OPTIONAL) General Slope(3:1 or less) / FLOW III I �II II �II 10' MIN 12' MIN.* �-- EXISTING Kentucky -Kentuc 31 Fescue 128 lbs. 4.' PAVEMENT - Red Top Grass 2 lbs. - Seasonal Nurse Crop " 20 lbs. 7— 150165. 3. ATTACH THE FILTER FABRIC TO THE WIRE 4. BACKFILL AND COMPACT THE - DRAINAGE LO' MIN. Low -Maintenance 5107�e (Steeper than 3:1) EXCAVATED FENCE AND EXTEND IT INTO THE TRENCH. SOIL. vOOr xt POSITIVE COURSE AGGREGATE 6 TO SEDIMENT I TRAPPING DEVICE - Kentucky 31 Fescue 108 lbs. MUST EXTEND FULL WIDTH - Red Top Grass 2 lbs. INGRESS AND EGRESS PLAN VIEW - Seasonal Nurse Crop ** 20 lbs. OF RATION Crownvetch *"* 20 lbs. 1T MIN. 150lbs. MIN. * Perennial Ryegrass will germinate faster and at lower soil temperatures than 3' MIN. fescue, thereby providing cover and erosion resistance for seedbed. Use seasonal nurse crop in accordance with seeding dates as stated below: III- FILTER CLOTH SECTION A —A March, April through May 15th .............. 6 ..... Annual Rye �— FLOW May 16th through August 15th ........ 6 . 6 ......... Foxtail Millet _ 6._71 August 16th through September, October ............. Annual Rye November through February...................... Winter Rye EXTENSION OF FABRIC AND WIRE INTO THE TRENCH. �_• * * * If Flatpea is used, increase to 30 lbs./acre. All legume seed must be properly - Inoculated. Weeping LOvegrass may also be included in any slope or low- IIIOV�N/�ll _ maintenance mixture during warmer seeding periods; add 10-20lbs/acre in mixes. NOTE: ALL SILT FENCES ARE TO USE 36 INCH FABRIC AND STAKED WITH 2"X2" HARDWOOD STAKES ON 6' CENTERS VESCH 3.05 SILT FENCE 1 STANDARD FILTER FABRIC FENCE ES-4 NTS S F SECTION B-B VESCH 3.02 TEMPORARY CONSTRUCTION ENTRANCE 2 ROCK CONSTRUCTION ENTRANCE ES-4 NTS C E VESCH 3.32 PERMANENT SEEDING 3 PERMANENT SEEDING ES-4 NTS TABLE 3.31-B ACCEPTABLE TEMPORARY SEEDING PLANT MATERIALS "QUICK REFERENCE FOR ALL REGIONS' Rate Planting Dates Species lbs. acre PLAN LO EXIST. GRADE P' 18" SILT FENCE OR 8" SILT SOXX (OR GREATER) rn SEED W/ VDOT FORMULA "C" IF NOT USED WITHIN 20 DAYS. 18" SILT FENCE OR 8" SILT SOXX (OR GREATER) NOTES: ELEVATION 1. INSTALL SILT FENCE DOWNSLOPE OF AREA OF STOCKPILE. 2. PLACE STOCKPILE IN AREAS SHOWN ON EROSION CONTROL PLAN WITHOUT BLOCKING NATURAL DRAINAGE PATTERNS. 3. FOLLOW DIMENSIONS SHOWN ABOVE. HEIGHT SHOULD NOT EXCEED 35 FT. SIDE SLOPES SHOULD NOT BE STEEPER THAN 2(H):1(V). 4. SEED IMMEDIATELY IF MATERIAL IS NOT TO BE USED WITHIN 20 DAYS. FOLLOW "SEEDING, FERTILIZATION SCHEDULE & SPECIFICATIONS." 5. LOCATION(S) AND SIZES) OF SOIL STOCKPILES ARE APPROXIMATE AND SHALL BE ADJUSTED PER FIELD AND CONSTRUCTION SEQUENCE CONDITIONS. CONTRACTOR SHALL VERIFY REQUIRED SIZE(S). REQUIREMENTS FROM THE STANDARDS DETAIL MUST BE FOLLOWED FOR STOCKPILES. 4 ES-4 TOPSOIL STOCKPILE AND MAINTENANCE TOPSOIL SPECIFICATIONS 1. TOPSOIL SPECIFICATIONS A. THE CONTRACTOR SHALL FURNISH ALL LABOR, SUPERVISION, MATERIAL (EXCEPT AS HEREIN PROVIDED), TOOLS EQUIPMENT, SUPPLIES, AND SERVICES; AND, SHALL PERFORM ALL WORK NECESSARY FOR PROVIDING (TYPE B AS NECESSARY) AND APPLYING TOPSOIL IN ACCORDANCE WITH THE REQUIREMENTS OF THESE SPECIFICATIONS AND IN CONFORMITY TO THE DEPTHS AND LIMITS SHOWN ON THE DRAWINGS OR AS ESTABLISHED BY THE OWNER. B. PRIOR TO USE OR PLACEMENT, THE CONTRACTOR SHALL SUBMIT CERTIFICATIONS OF SOIL TESTS FOR APPROVAL. SOIL TESTS SHALL BE PROVIDED AT THE RATE OF ONE TEST PER 10,000 SQUARE FEET OF DISTURBED AREA. C. UNLESS OTHERWISE DIRECTED BY THE OWNER, AREAS DESIGNATED TO RECEIVE TOPSOIL SHALL BE GRADED, SHAPED, AND THEN SCARIFIED OR TILLED BY DISKING, HARROWING, OR OTHER APPROVED METHODS TO A DEPTH OF APPROXIMATELY 2". TOPSOIL SHALL BE APPLIED ONLY WHEN THE SUBSOIL IS IN A LOOSE, FRIABLE CONDITION. D. THE CONTRACTOR SHALL PROTECT BENCHMARKS, UTILITIES, AND EXISTING TREES, SHRUBS, AND OTHER LANDSCAPE FEATURES DESIGNATED FOR PRESERVATION WITH TEMPORARY FENCING OR BARRICADES SATISFACTORY TO THE OWNER. E. SUBSOIL ON SLOPES THAT HAVE BEEN HORIZONTALLY GROOVED IN ACCORDANCE WITH THE DRAWINGS SHALL NOT BE LOOSENED. F. THE LOOSE DEPTH OF THE CLASS OF TOPSOIL SHALL BE NO LESS THAN 4" (NOT LESS THAN 6" IN MEDIANS: AND SHALL BE SUFFICIENT TO ALLOW THE AREA TO CONFORM TO THE ELEVATIONS SHOWN ON THE DRAWINGS AFTER TOPSOIL SETTLES. IN NO CASE SHALL THE CONSOLIDATED FINISH ELEVATION OF TOPSOIL EXCEED THE ELEVATION OF ADJACENT STRUCTURES. CONSOLIDATED ELEVATION SHALL BE FLUSH WITH THE ADJACENT STRUCTURES. G. AFTER TOPSOIL HAS BEEN APPLIED, LARGE CLODS, HARD LUMPS, AND STONES MORE THAN 1" IN THE GREATEST DIMENSION, BRUSH, ROOTS, STUMPS, LITTER, AND FOREIGN MATERIAL SHALL BE REMOVED FROM THE AREA. WHEN THE OPERATION IS COMPLETE, THE AREA SHALL BE IN A CONDITION TO RECEIVE SEED, SOD, OR PLANTS WITHOUT FURTHER SOIL PREPARATION. AREAS SHALL BE STABILIZED WITHIN 15 DAYS AFTER TOPSOIL IS APPLIED. H. THE CONTRACTOR SHALL BE REQUIRED TO BACKFILL ALONG EDGES OF CURBS, SIDEWALKS AND ENTRANCES WHERE SETTLEMENT HAS OCCURRED AND RESHAPE AND RESLOPE, WHERE DIRECTED, PRIOR TO PLACEMENT OF TOPSOIL AS WELL AS TO ADD ADDITIONAL TOPSOIL AS REQUIRED DUE TO SETTLEMENT OR EROSION AT NO ADDITIONAL COST TO THE OWNER. Sept. 1 - Feb. 15 50/50 Mix of Annual Ryegrass (Lolium multi-florum) & 50 - 100 Cereal (Winter) Rye (Secale cereale) PR( Feb. 16 - Apr. 30 Annual Ryegrass 60 - 100 (Lolium multi-florum) CLEARIN May 1 - Aug 31 German Millet 50 (Setaria italicaitalica) VESCH 3.31 TEMPORARY SEEDING 5 TEMPORARY SEEDING ES-4 NTS TS NO STANDARD CONSTRUCTION NUMBER NOTES: 1. THE TREE PROTECTIVE BARRIER MUST CONSIST OF ORANGE SAFETY FENCING, NOT LESS THAN THREE FEET HIGH AND SUPPORTED BY WOOD/METAL POLES. 2. THE TREE PROTECTIVE BARRIER WILL NEED TO REMAIN IN PLACE THROUGHOUT CONSTRUCTION. 3. APPROVAL OF TREE PROTECTIVE BARRIER WOULD NEED TO OCCUR PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND FINAL SITE PLAN APPROVAL. VESCH 3.38 TREE PRESERVATION AND PROTECTION s TREE PROTECTION FENCE TP ES-4 NTS rr LU W Z c� z LL1 Z O Q 0 LU C0 TOTALLY COMMITTED NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonl/ 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 06/10/20 REVISED CT 0 M O 5 04/20/20 REVISED CCC U LU 4 03/09/20 REVISED PJP Z C� 3 02/24/20 REVISED PJP LU E 2 12/04/19 REVISED CCC a- Q Q Z O Cn CIS LU IL a- rr LU LU z_ U Z LU UJ J w LU Cn rr- LU m z LU LU CO 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD LJS REV DATE DESCRIPTION BY 2 XA v JOHN A. DAUGHTREY III .,� Lic. No.0402052122 06/10/2020 <v� �lSA]A1 .a JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION SEDIMENT CONTROLI DETAILS I ES-4 TM 1' SHOULDER ® 6% L BASE COARSE: 6" DEPTH OF COARSE AGGREGATE 2"-3" STONE (AASHTO #5 OR RAILROAD BALLAST) \7� 12' STANDARD 3% 1' SHOULDER ® 6% WA v�o �uo �0000� 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O0T0000000a a 00000OOC�nnnnnnn� COMPACTED SUBGRADE 3% 2' SHOULDER ® 6% 12' STANDARD SURFACE COARSE: 6' DEPTH OF FULLY GRADED CRUSHED 1"STONE AND SMALLER MIXED WITH DIRT AND FINES (CRUSHED AGGREGATE BASE COARSE OR CABC). GEOTEXTILE (SEE NOTE) 3% �O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �C 0 0 0 0 0 0 00 0 0 0 0 0 co SURFACE COARSE: 6" DEPTH OF FULLY GRADED CRUSHED 1"STONE AND SMALLER MIXED WITH DIRT AND FINES (CRUSHED AGGREGATE BASE COARSE OR CABC). COMPACTED SUBGRADE �j 2' SHOULDER ® 6% BASE COARSE: 6" DEPTH OF COARSE GEOTEXTILE AGGREGATE 2"-3" STONE (AASHTO #5 (SEE NOTE) OR RAILROAD BALLAST) NOTES: 1. SUBGRADE AND FILL SHALL CONSIST OF CLEAN SOIL. NO DELETERIOUS MATERIALS OR ORGANICS TO BE USED. FREE OF FROZEN PARTICLES, ORGANIC MATTER, CLAYED MATERIAL AND ROCK PARTICLES GREATER THAN 12" IN ANY DIRECTION. 2. REMOVE ALL TOPSOIL AND ORGANICS BEFORE COMMENCING ACCESS ROAD FOR A MIN. DEPTH OF 12". 3.CONTRACTOR TO USE 6" DEEP GRAVEL BASE (2A MODIFIED) AS MEANS OF ACCESS FOR ALL HEAVY CONSTRUCTION TRAFFIC. PROPOSED GRAVEL SURFACE (6" DEEP CRUSHER RUN) TO BE INSTALLED AFTER ALL MAJOR CONSTRUCTION HAS BEEN COMPLETED. 4. THE PROPOSED ROAD MUST BE KEYED INTO THE EXISTING GRADE. THE FINAL FINISHED GRADE SHALL BE FLUSH WITH THE EXISTING GRADE TO ALLOW FOR PROPER DRAINAGE ACROSS THE ROAD. 4. WOVEN GEOTEXTILE: APPROVED PRODUCTS ARE US FABRICS: US 200 AND TENCATE: 160N. CONTRACTOR MAY SUBMIT DESIGN ALTERNATIVE. PROPOSED GRAVEL DRIVE TYPICAL SECTION NTS m W LLI z c3 z w z O Q Cr 0 z w cn 0 Li- 0 U w fr z co W n IZ CJ J z O U) U) w w Ir n n- w w z_ 0 z w w J LJ w w Cr w Ib z w w UD TOTALLY COMMITTED. NB+C ENGINEERING SERVICES, LLC. 4435 WATERFRONT DRIVE, SUITE 100 GLEN ALLEN, VA 23060 804-548-4079 verizonil 1831 RADY COURT RICHMOND, VA 23222 WILD TURKEY WILD TURKEY LANE CHARLOTTESVILLE, VA 22903 ALBEMARLE COUNTY REVISIONS 6 06/10/20 REVISED CT 5 04/20/20 REVISED CCC 4 103/09/201 REVISED I Pip 3 1 02/24/201 REVISED I Pip 2 1 12/04/19 1 REVISED I CCC 1 11/18/19 FINALS CCC 0 10/30/19 PRELIMINARY CD US REV I DATE I DESCRIPTION I BY [ H O F L�9 o � XA JOHN A. DAUGHTREY III _0 Lie, No. 0402052122 �O 06/10/2020 1, (OA7AI JOHN A. DAUGHTREY III, P.E. VA PROFESSIONAL ENGINEER LIC. #052122 EROSION SEDIMENT CONTROLI DETAILS II ES-5