Loading...
HomeMy WebLinkAboutSDP202000023 Review Comments Final Site Plan and Comps. 2020-08-10� AI ?"h �IRGINrP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 229024596 Phone (434) 296-5832 Fax (434) 972-4126 Project: Project file number: Plan preparer: Owner or rep.: Applicant: Plan received date: (Rev. 1) (Rev. 2) (Rev. 3) (Rev. 3a /update) Date of comments: (Rev. 1) (Rev. 2) (Rev. 3) (Rev. 3a /update) Reviewer: Project Coordinator: Site Plan review Martha Jefferson Hospital Presidio Apartments - FSP SDP2020-00023 Scott Collins; Collins Engineering [200 Garrett St., Suite K, Charlottesville, VA 22902, scott(a)collins-engineering.coml Presidio Pantops LLC / 455 Second St. SE 5t' Floor Charlottesville, VA 22902 [ alanAriverbenddev.com ] Castle Development Partners LLC / 230 Court Square, Suite 202 Charlottesville, VA 22902 19 Mar 2020 26 May 2020 19 Jun 2020 - digital /dropbox 17 Jul 2020 (retaining wall design); Rev. ESP 4 Aug 2020, link to complete FSP (8/4/2020 2:27 PM) 2 May 2020 6 Jun 2020 25 Jun 2020 23 Jul 2020 -Note: Need complete FSP to complete review 10 Aug 2020 John Anderson - No objection Cameron Langille Note: Given review constraints, Engineering welcomes .PDF preview of revised final site plan andFelated �W9201800027. Preview SIT at this point implies accelerated review er-pfierit3,-review ahead of competing items in review queue/s, if possible. (Rev. 2) Engineering welcomes .PDF preview of Hillis - Carnes' (HC) revised design of the retaining walls. (Rev. 3) Engineering requests link to complete 7/23/20 FSP, and requests that the current FSP display actual revision date, which may be later than 30-Jun 2020. (Rev. 3a) With link to complete FSP, comparison with Hillis -Carnes retaining wall (RW) design possible (PE -seal date 7/10/20). Prior review comments addressed. See pg. 12 for sample comparison of HC RW design with FSP. SDP202000023 (Also, SDP2019-00075 comments, which are basis of Engineering Final Site Plan review comments.) PIP - Peter Jefferson Parkway (Ex.) ACDSM -Albemarle County Design Standards Manual Note: Engineering is grateful for Applicant's immediate written response (1/23/2020 10:42 PM), which reflects sincere interest in limiting comments effect on ISP approval. That Collins Engineering (CE) affords chance to revise comments prior to expanding audience is considerate. Comments relating to guardrail along PIP, review errors, are withdrawn. CE coordinated with VDOT on this (and other projects), and reports slopes graded 3:1 or flatter do not require guardrail (grayscale ikethFetlg :.) Discussion with CE may help resolve line work comments. CG-6 (with gutter) for concentrated runoff in parking areas and travelways is the expectation. CG-2 is fine for high side of parking areas. Appleton Way must meet VDOT Road Design Manual and county code requirements (CG-6 on both sides of the travelway). Parking areas must meet county code requirements. Since this is a site plan, requirements listed at 18-4, 18-32, and Ch. 14 apply to various degree. ACDSM applies. Review errs in stating storm pipe grade of 0.50.0.52. and 0.53%, may not be approved. They can be. Albemarle, having revised review to recommend increase in slope (0.60%) may take skeptical stance concerning any pipe at any depth installed at less than county stone pipe min. slope. Initial comment should have recommended conservative design. As -built drawings routinely reveal pipes (designed at 0.50%) installed at <0.50%, which may lead to failure and expense to remedy. 25 comments identified objectionable are highlighted red. A portion are withdrawn (grayscale/^�-"�..,, ed o"---e :), a portion maybe revised after discussion. Comment 4 is withdrawn provided Engineering Review Comments Page 2 of 12 the ISP plan explicitly states topographic survey performed in support of design meets state code requirements for surveys; otherwise, Albemarle has insufficient information at this point, and cannot assume an aerial survey meets state code. Given this, no comment imperils initial site plan approval from Engineering perspective. Comment #4 has been discussed internally, and Engineering anticipates written response from a licensed surveyor. Engineering is appreciative of thoughtful Applicant response. Misplaced review comments place a burden on Applicants that we hope to avoid. Review errors relate to: guardrail along PIP, inadequate research of suitability of HDPE pipe (permissible to use), and to possible misunderstandings. We regret mistakes. In one day, CE revised ISP in response to comments. Albemarle commends remarkable response. Engineering has not reviewed revisions, but revisions address many comments, now shown in light grayscale. (These will be checked with plan re -submittal.) * Comments relating to guardrail (PJP), prompted by safety concerns, are withdrawn. Request for guardrail along the entire west side of Appleton Street (design relies on retaining walls and slopes steeper than 3:1 above unrecoverable slopes), addressed. Sheet 1-A 1. Recommend revise site plan title to include SDP201900075, Initial Site Plan (FSP) As follow-up: Recommend include SDP202000023 in final site plan, plan title. (Rev. 1) Addressed, 2. Revise SWM Note to include ref. to W0O201800027. Note 1: SWM Facility easement plat is under review. Easement plat recordation required for WPO Plan approval. Note2: SWM Facility Easement widths should be checked against ACDSM, Easement width diagram, ACDSM, p. 15. (Link: https://www.albemarle.org/upload/images/forms center/departments/community development/forms/design standards _manual/Albemarle County Design Standards Manual 2015-04-25 draft.pddf ) 3. Revise Additional Notes: a. (Rev) R.eeenp. le, Notes � and 7, Maieh indicate public stwets (streets in the jovelopment aFe { vat ys). Withdrawn (Clarification to be added to plans.) b. (Rev) Revise Note 6i Drainage easements upstwam of SIVA14 delention eF tFealfflent facil t es Are °SlAr hT facil,ly aFepublie easements,dediioatedto publie use. Withdrawn (Clarification to be added to plans.) c. (Rev) nP;ayidde de 4^n:on nele fe. r cn rr (cur .,.,a rvur so Note 9 may be aluatee^gainst design. Coup.., .,....,. Gig .._ee of 1cn plevation :...,,.eeptable. Withdrawn (ARB purview.) d. Note: Note 2 stating that site travelways will not meet the standards for acceptance into the secondary system of state highways may appear to suggest a standard less than VDOT design for this development. VDOT standards apply to drainage, and to site Travelway A /Appleton Street pavement (depth) sections, entrance geometry, and FC-FC width, as well as on -street parking (Appleton Street). Ref. ACDSM and Code 18-32.7.2.2.a., 14-4I0.(B.,F.,G.,H.,L). Also, Final Site Plan checklist for plan reviewers, p. 2, Entrances. Also, 14-412.B. (Rev) Note serves as reminder VDOT standards apply to travelway /drainage design (note does not request plan revision). 4. Topo and survey: Aerial survey performed by Virginia Resource Mapping dated January 2006 (with field verification by Collins Engineering, August 2019) is insufficient basis of design. Engineering recommends Applicant contact GIS /Ruth Emerick to discuss this review comment. Note: Ms. Emerick anticipates extended leave in the near future. Until an acceptable source of topography is basis of design, Engineering recommends disapproval of ISP, and resubmittal of ISP with acceptable basis of topographic design. (Rev) Comment revised. Ref. JA email to Applicant January 24, 2020 10:50 AM), also, please see above. Comment 4 is withdrawn once ISP plan explicitly states topographic survey performed in support of design meets state code requirements for surveys, otherwise, Albemarle has insufficient information (at this point) and does not assume that aerial survey meets state code. Given this, no comment imperils initial site plan approval from Engineering perspective. Comment 44 was reviewed, internally. Please provide a written certification from licensed surveyor that 2006 aerial survey basis of design meets state survey requirements. (FSP) Partially addressed. Applicant response: `As discussed in the meeting on March 5', Roudabush and Gale have performed additional onsite survey and topography on the site, and have confirmed that the topography is accurate. This additional topo information has been added to the plan sheet and the note on the cover sheet has been updated to reflect this additional information.' Asfollow-uj2: Revise (1A) Topo and Survey Note as requested in lead paragraph, p. 1. Please state that `topographic survey performed in support of design meets state code requirements for surveys.' This was discussed internally, would seem non -objectionable. The site plan is not a plat, does not carry a LS seal, so we restate request for this specific language on the final site plan. Also, please provide date/s of recent survey plats. Recent is non-specific. (Rev. 1) Addressed. Engineering Review Comments Page 3 of 12 5. Revise sheet index to list demolition plan (sheet), retaining wall design, or any other change to plan index. 6. Sheet 2: Existing site elements will be demolished (Ex. gaarAfail /asphalt walk /PJP curb, for example). Provide separate demolition sheet with details of items to be removed (TBR). Please note that Ex. .....,_a_.,May en4, be Femoved to Provide site aeoess. Ex. guaFdFail not Fequired to be remain n t deail�a.� '^ 4. (Rev) Portion of comment relating to guardrail is withdrawn, rest, persists. (FSP) Addressed. Applicant:'_ this portion of the guardrail is being removed per VDOT requirements.' Sheet 3 7_ Label trails 8. Show dthmpsto_. ifa.... Asters aFe .._..yided at each building. (Rev) Withdrawn, dumpsters are not provided at each building. 9. Recommend show sight distance lines at internal travelway intersections on this sheet, they must be shown on sheets 4/5 Ref Code 18412.15.d. For example Appleton St_ and Moraga St.; Appleton and parking ar ind I; Travelway A an(' ppleton and Fisher Street. 10. Evaluate all parking spaces in parking areas for adequate corner clearance with Appleton Street, Ref. Final Site Plan checklist for plan reviewers, p. 3, second item. (Rev) Ref. 18-32.7.2.2: `... Each private street and travelway within a development shall be designed and constructed to the standards for private streets in chapter 14.' 14-412.13. (Private streets serving non-residential, non-agricultural, attached residential, multi- unit residential and combined residential and non-residential uses): `Each private street... shall satisfy Virginia Department of Transportation standards or an alternative standard deemed adequate by the agent, upon the recommendation of the county engineer, to be equivalent to or greater than the applicable standard in the design standards manual, so as to adequately protect the public health, safety or welfare.' ACDSM: page 19 / — standards for private streets in Albemarle County: [ removed w/ FSP comments. ] (FSP) Addressed. Applicant: `As discussed at the March 5' meeting, the parking lot entrances from the main travelways have been updated and reflect the requested turning radii. The location of the parking spaces in conjunction with the intersections have been updated to ensure adequate clearances. The auto turn has also been shown on the plans. In addition, only the requirements of [Ch.] 18 apply to the development and not the requirements from Section 14, which is the subdivision of land. Because no land is being subdivided, there are no private streets, only private travelways.' I I _ Do not show existing Ceatures TBR, existing trail /walk along PJP, Lor example_ This comment applies to a// plan sheets_ 12. Align detectable surface in direction of pedestrian travel. Revise to reflect proper alignment of detectable surface. Show radial detectable surface in radius curves. Revise to remove CG-2 curbing at CG-12 ramps. All line work and site features should accurately reflect design intent. Design should minimize ambiguity. This comment applies to all plan sheets. (Ref. /include CG-12 detail, sheet 10) (Rev) A possible misunderstanding' not a request to remove tie-in (CG-2 or CG-6 to CG-12' transition understood). Just do not want CG-2 /-6 to be shown continuing unbroken across base of CG-12 ramp —regret misunderstanding. (FSP) Partially addressed. As follow-up: Please see sheet 10 VDOT CG-12 detail, lower -left corner of detail, which depicts plan view alignment of detectable surface in a radial curb. Revise layout plan CG-12 wherever inconsistent with VDOT detail (ramps in radial curbs, multiple locations), else contractor may install improperly. Goal is to avoid later tear -out /replacement to meet VDOT CG-12 standard. (Rev. 1) Addressed, 13. Show /label internal stop /yield signs at internal intersections (travelways /parking areas) to establish which thru movement has precedence /right-of-way. Applies to plan sheets 4 and 5, as well. Sheets 4, 5 14. Provide CG-12 wherever asphalt travelway or parking surface runoff is concentrated /conveyed to a storm inlet. Design must provide curb and gutter (18-4.12.15.g). Note recent review comment for 2415 Ivy Road Redevelopment. Waiver, if requested, will likely be disapproved. Ref. 2415 Ivy Road Redevelopment waiver request. Storm conveyance is a priority. Gutter is required by county code, and runoff in parking areas with grade z5% is concentrated. (Note: It appears all inlet capacity and spread calculations include gutter cross -slope, so gutter is assumed in design calculations.) (Rev). Applicant response (1/23/20): `We Engineering Review Comments Page 4 of 12 will provide CG-6 on the curbs that channel water to a drainage structure, but the remaining curb will all be CG-2. This is consistent with the design manual.' Engineering accepts this response. (FSP) Addressed. 15. Eliminate CG-2 at CG-12 ramps. (Rev) Please see item 12, above. (FSP) Withdrawn. 16. Provide and label stop and yield signs. 17. Label site street name/s and stop signs at PIP entrances. 18. Show bumper blocks for parking spaces in front of 5' sidewalks. (FSP) Partially addressed. As follow-up: Several 6' walks appear to need labels, ensure all 6' walks adjacent to 18' L parking spaces are labeled. (Rev. 1) Addressed. 19. Revise labels for any proposed wall with wall ht. >30" to proposed wall with handrail. (FSP) Partially addressed. As follow-up: Revise sheet 5 (elsewhere, if needed) Note specifying handrail for wall ht. > 6'. Handrail is required for retaining wall height >30". (Rev. 1) Addressed. 20. delai1q. Pnqiffe sheets 4 and 5, and sheet 10 pi:wate 4avolway details (width, notes, seetion [asphalt, basol) afe e0H5i5feR4 With Effie and with applieable VDOT- design, ineleding 3,11)OT- feed design and ,damage mantia1_ and VDOT- 2018 pavemeR4 design guide. (Rev.) Withdrawn. Applicant response: `Easement width has been provided over Appleton. Easements are not required on the other travelways in an apartment complex.' Engineering accepts this response. 21. Eliminate CG-2, which does not provide gutter. (Rev) Please see item 14, above. (FSP) Addressed. 22, Provide CG-6, as requested elsewhere. 23. Align detectable surface with direction of pedestrian travel. Provide radial detectable surface detail on this plan view sheet, and provide detail on sheet 10, as requested elsewhere. (FSP) Partially addressed. As follow-up: See item 12, above. (Rev. 1) Addressed. 24. Include ref, to sheet 10 detail for proposed 5' trailway. Sheet 10 includes 5' asphalt pedestrian trail detail, and Class A — Type 1 low maintenance pedestrian pathway detail (both w/ asphalt surfaces), but does not include detail that corresponds with proposed 5' primitive trailway. Note: sheet 4 identifies the same pedestrian facility as both a 5' trailway and a primitive trailway, which differ. Please revise for clarity. 25. Revise 16' L parking spaces fronting 6' walkway width, design is impermissible. Ref. ACDSM, Sec. 7.c.6. (18' L fronting 6' sidewalk is acceptable). 26. Provide Autotum figure (typical passenger vehicle). Eliminate any travel width issues with revised design: a. 12' R entrance, travelway B onto Moraga Street (N intersection), (FSP) Not addressed. Provide auto turn at this location (sheet 4). (Rev. 1) Addressed. b. Rt. Tom in at 6' R entrance, Appleton into parking areas S of building 1, and 5, (FSP) Addressed. c. Rt. Tom in at 12' R entrance, Appleton onto Fisher Street, (FSP) Addressed. d. Ensure entrance radii are 12.5', minimum, (FSP) Addressed. Minimum design radius =12'. e. Revise any entrance into any parking area or internal travelway that does not meet 14-410.B. Angle of intersection design requirement, which stipulates angle of intersection be not less than eighty (80) degrees. See entrance from Appleton into parking area S of building 1, which is —45 degrees. This entrance does not meet min, entrance radii. Autotum may reveal other issues. (Rev.) Applicant response: `We need to discuss this comment [26.a.-e.] as it seems excessive for a parking lot design in an apartment complex.' Turning movements are less problematic with right angle design, but acute turning movements are required with this design, Engineering must ensure vehicles may pass without collision. Request for Autoturn for turning movements off Appleton are not within a parking lot, but primary site access and are evaluated against VDOT standards. Also, item 10, above. (FSP) Partially addressed. Applicant response: `As discussed at the meeting on March 5'", the auto turns have been added to the plan sheet and graphically shown on sheets 4 and 5. Even though the travelways are not required to be designed to street standards, the radii have been updated based on the auto turns, to ensure safe and adequate travelways through the site.' As follow-up: see item 26.a., above. (Rev. 1) Addressed. 27. . See a:..,.......:on relating to else .lio-e. (Rev) Withdrawn. 28. Do not show portions of Ex. trail along PIP that will be demolished. (Rev). Once Ex. trail across front of development is demolished, it does not need to appear on site plan sheets showing improvements. (May be easier to discuss.) (FSP) Addressed. 29. Label entrances with a VDOT designation (CG-9a, etc.), especially Appleton Street onto internal travelways, or areas mentioned elsewhere. Engineering Review Comments Page 5 of 12 30. Provide travehvay stationing corresponding with sheet 18 and 19 travekvjq profiles_ Additional commenu possihle once stationing shown_ 31. Provide detailed PE -sealed geotechnical retaining wall design (not generic design) for any walls supporting infrastructure; for example: walls west of Appleton Street and tiered retaining walls upslope of wet pond. Ref. Retaining Wall checklist for reviewers. Revise plan set index to accommodate additional plan sheets. (ESP) Not addressed. Applicant response: `As discussed at the meeting on March 5 ", the retaining wall designs will be submitted for a building permit during the building construction aspect of the development. The site plan will be approved, and the approved site plan will be submitted with the building permit application and wall designs.' As follow-up: There is an issue with Applicant response: Unless Applicant can provide contemporaneous meeting notes, Engineering recollection differs. Standard review practice is outlined in published documents that guide review of virtually all projects. Engineering restates request for detailed wall designs. Please ref. Final Site Plan checklist for plan reviewers, last item, p. 1 /attached. Also, Retaining Wall Plan checklist for plan reviewers, attached. Information listed in checklist documents is required prior to Final Site Plan approval. (Rev. 1, D Partially addressed. As follow-YJ2: A comprehensive retaining wall design by Hillis -Carnes (HC) Engineering (cover undated /without professional seal) was submitted. Retaining wall (RW) sheets 2-18 are d. Feb. 7, 2020. Plans include overall (plan view) index, profile for ea. wall, with stationing, and typical details. Profiles for forty (40) proposed site retaining walls: a. Walls: (Rev. 2) Comment persists. Applicant response: `Hillis -Carnes' (HQ design of the retaining walls is being updated to match Collins Engineering's (CE) current plans.' Engineering appreciates this response. (Rev. 3a) Addressed. i. IA— 1H (8 walls), near building 1 /or along Appleton St. ii. 2A — 2E (5 walls), near building 2 iii. 3A — 3H (8 walls), near building 3 iv. 4A-4D (4 walls), near building 4 v. 5A-5F (6 walls), near building 5 vi. 4A-4D (4 walls), near building 6 vii. Wall Pond A, B, C, D, E (5 walls), near pond, Note: Wall 4B is continuous from well N of building 4 to W end of wet pond, L=827.5'. b. As follow-up: i. Revise site plan grading or RW design for consistency. Apparent inconsistencies 1. Wall 4B (Rev. 2) Addressed. Applicant: `On sheet 9, immediately below Moraga Street's station 16+00, retaining wall 4B previously showed an incorrect TW elevation of 427'. Sheet 9 now correctly lists the top of wall elevation as 426'. Also, the HC design incorrectly listed this wall height's maximum height as 8' and it will be corrected.' HC-8 [ Rev. 1 image removed with Rev. 2 comments. ] HC-9 [ Rev. 1 image removed with Rev. 2 comments. ] Final Site Plan, sheet 9 (FSP-9): [ Rev. 1 image removed with Rev. 2 comments. ] 2. Note: all five TWBW labels in image above indicate 7' ht. Compare with Max. height =6' label. Revise for consistency /per ACDSM, 18-30.7.5, as applicable. (Rev. 2) Addressed. Applicant: `On sheet 9, the previous CE plans incorrectly listed a maximum wall height of 6' for Wall Pond A, B, C, D and Wall 4B. Sheet 9 has been revised, in the middle -right portion of the page, to list a maximum wall height of 7' in the vicinity of the wet pond for Wall Pond A, B, C and D. Also, Wall Ponds B, C and D transition to a maximum height of 6' further to the east. Sheet 9 was updated to label this, as well as to provide additional transitional spot shots. Additionally, there is a small 5' horizontal section at the end of Wall Pond A that encroaches into the end of a County defined steep slopes area. The wall in this 5' horizontal section has a maximum wall height (2') that is less than the 6' threshold. Sheet 9 has been updated Engineering Review Comments Page 6 of 12 accordingly. Lastly, in a June 18' phone conversation between Mr. Murray of CE and Mr. Anderson of County Engineering it was confirmed maximum wall heights may exceed 6' outside of steep slopes, but walls within steep slopes must not be greater than 6'. The plans reflect this.' 3. Note: HC-8/-9 and SP-9 elev. differ by —2.5'. Revise for consistency /accuracy. (Rev. 2) Addressed. Applicant: `Sheet 9, in the middle -right portion of the page immediately adjacent to the border, previously listed (incorrectly) the maximum wall height as 7' in this area. The plans have been revised to now read a maximum wall height of 6' in this vicinity. Please also see response above to comment 3 La.' 4. HC-1 is inconsistent with later HC RW design sheets. C,....paw, r _ o. . ple s of 14C 8/ o (above) with 14C ,.oyeF (below) Wall 4B, image belo Note: HC plans appear internally inconsistent and inconsistent with FSP). HC-cover. [ Rev. 1 image removed with Rev. 2 comments. ] (Rev. 2) Addressed. Applicant: `Please see response above to comment 3 La., 5. FSP-9 Wall 4B TW-BW labels inconsistent with HC-cover. Revise for accuracy. (Rev. 2) Addressed. Applicant: `Please see response above to comment 3 La. and 3 Lb.1. The bottom of Wall 4B remains at elevation 420, and the wall has a maximum wall height of 6'.' 6. Transfer HC wall labels to ESP sheets 8, 9. (Rev. 2) Addressed. Applicant: `Sheets 8 & 9 were updated to label the retaining walls.' 7. Pond Wall E (Rev. 2) Addressed. Applicant: `Wall Pond E correctly lists the maximum top of wall elevation as 432' and the bottom of wall elevation as 428'. Please also see response above to comment 3 La.' a. HC-14 /FSP-9 TW labels are consistent (432'). b. HC-cover /FSP-9 TW labels are inconsistent: 434' v. 432' respectively. c. HC-cover /HC-14 TW labels are inconsistent: 434' v.432' respectively. d. HC-1 /FSP-9 BW labels are inconsistent: 429' v. 428', respectively. e. HC-1 /HC-14 BW labels are inconsistent: 429' v. 425', respectively. 8. Wall 4D (Rev. 2) Addressed. Applicant: `Sheet 8 correctly lists the top of wall elevation as 408' and the bottom of wall elevation as 402' for the majority of its run. Sheet 8 was updated and now shows additional spot shots at the beginning and ending transitional lengths for clarity. The maximum retaining wall height when in steep slopes is 6', as shown, in accordance with County requirements. Please also see response above to comment 31.a.' a. HC-cover /FSP-8 TW-BW labels are consistent (408'- 402'). b. HC-10 /FSP-8 TW labels are inconsistent: 406'- 408'. c. HC-cover /HC-10 TW labels are inconsistent: 408' - 406'. d. HC-10 /FSP-8 BW labels are inconsistent: 399' - 402'. e. RW design proposes 7.66' wall on Managed Steep Slopes. Max, ht. =6'. Revise. HC-14 (TW=432.33: BW = 425.33') — Wall Pond E [ Rev. 1 image removed with Rev. 2 comments. ] HC-10 (TW=406.33; BW = 398.67') — Wall 4D, Note: Wall height =7.66' [ Rev. 1 image removed with Rev. 2 comments. ] HC-cover, Wall 4D [ Rev. 1 image removed with Rev. 2 comments. ] FSP-8 [ Rev. 1 image removed with Rev. 2 comments. ] (Rev. 2) Addressed. Applicant: `In the aforementioned June 18`h phone conversation, it was determined labeling the beginning wall stations (0+00) and the end of the walls on Collins Engineering's plans was sufficient to address comment 8.ii since the timing and completion of CE's plans likely will precede the timing and completion of HC's plans. As such, sheets 8 and 9 have been revised to add the following labels to each retaining wall: Sta 0+00 and End. Also, please see response above to comment 3 La.' Engineering Review Comments Page 7 of 12 ii. Provide site plan wall stations to guide inspection and review, at a minimum, label site plan with Hillis -Carnes retaining wall begin (0+00) /end stations. Provide 100' station ticks /labels, or closer spacing. iii. Ensure HC Engineering plans are sealed (P.E. /geotechnical), with seal signed and dated. iv. Additional comments possible. c. Note: i. Elevation departure between retaining wall design and plans should be negligible for ESP approval. (Rev. 2) Addressed. Applicant: `Additional spot shots were added to CE's plans to provide farther clarity. Special attention was also given to the perimeter walls, where elevations along the walls transition more.' ii. Retaining wall plans must be internally consistent and accurate. (Rev. 2) Addressed. Applicant: `(ii and in) Please see the response above to comment 3 La., iii. Retaining wall plans must be consistent with ESP TWBW design elevation labels, tie-in grades, etc. iv. Design includes forty (40) retaining walls, all relevant to site layout, many critical to parking, buildings, etc. (Rev. 2) Addressed. Applicant: `(iv-vii) These comments are acknowledged. CE has provided additional retaining wall spot shots to provide further clarity. Please also see the response above to comment 3 La.' v. All initial (3) comparison checks for consistency revealed issues. vi. Given multiple review issues with each of first 3 of 40 retaining wall comparisons, review is suspended pending Applicant revision of grading, ESP, HC RW designs, across all sheets (with care /adequate QC) to resolve Max. height, labeling, grading, cross -plan, and internal design inconsistencies and inaccuracies. vii. Given scope of change, follow-up Engineering ESP review may not be immediate. 32. Provide oil -site CG-12 receiving ramp on the N side of PJP, for ramp on south side of PJP_ 33. Show site entrance lane striping for turn lanes located on PJP. 34, At S end of Travelway B, revise CG-2 at small island at extreme S end of parking E of building 3 to roll- top curb; otherwise, CG-2 may not endure_ 35. In same general location, extend and label GR-2 to protect 6 additional parking spaces which face south (4) or east (2) located upslope of retaining walls (and not currently afforded guardrail barrier protection). (Rev.) 3:1 slopes above a retaining wall require guardrail. Albemarle required guardrail for a separate site plan with flat slope with curb facing a retaining wall in 2019 (Oak Hill Convenience Store). (FSP) Partially addressed. As follow-up: Please provide VDOT GR-2 (guardrail) for 11 radial parking spaces shown on sheet 8 (northernmost section of Travelway B parking lot). (Rev. 1) Addressed. 36. Provide drainage (ditch, etc., with adequate velocity dissipation at end of ditch line) for Driveway Access, Note: Driveway access appears to be Ex. gravel road to be removed (TBR) on sheet 2. Please clarify. (Rev) It may be easier to discuss, please schedule a meeting. (FSP) Withdrawn. Applicant response: `As discussed in the meeting on March 5'", the driveway will have a cross slope and will not collect or create [a] ditch to channel the runoff. The runoff will pass over the roadway, therefore, no ditch or outfall design is necessary.' Sheets 6, 7 37. Label all proposed private yard drain inlets. All inlets that appear in calc. tables (sheets 15, 24) must be labeled in plan view. Also, provide storm profiles for all drainage, including roof leader and yard grate systems. Display graphically with INV information, each point where Nyloplast roof /yard pipes enter structures. Show in drainage profiles. Label these storm conveyance elements (sheets 16, 17). Note: Please see review recommendation or request for design revision relating to allowable storm pipe material type, or system type, specifically relating to depth of fill (-30' in certain locations), listed elsewhere. (Rev) Applicant response: `We have never been required to provide profiles for yard drains and roof leaders. This comment is excessive and needs to be removed. We will provide a drainage schedule for these inlets and roof leaders, but will not provide profiles.' Please ref Drainage Plan Checklist (p. 1-2) Drainage prot➢es: (applicable to site plans, road and drainage plans) [14-311, 18-32] drainage profiles for each pipe, structure or channel must contain: existing ground proposed ground any channel linings Engineering Review Comments Page 8 of 12 all utility crossings a VDOT designation (MH-1, DI-3B, etc.) for each structure throat length for each drop inlet grate type for each grate inlet a label on each structure to correspond with the computations material and strength class or gage of each pipe manhole access every 300' for 15"-42" or 800' for 48" or greater pipe slopes at 0.5% min. to 16% max. (per VDOT studs for anchors over 16%) concrete inlet shaping (IS-1) specified on any structure with a 4' or greater drop safety slabs (SL-1) in any structure taller than 12'. top or rim elevation for each structure all invert elevations for each structure (with positive flow drop between inverts). end sections (ES-1) or endwalls (EW-1) on all pipe outlets. Endwalls for culverts 48" or taller scour outlet protection at all outlets, corresponding to computations (Green Brook, OP) Roof leader lines and yard drains are not incidental items with this design, at times they are, but nearly all (save 2) roof /yard grates lead to parking /road DI -pipe system. Roof -yard systems pass beneath retaining walls, and there may be conflicts. Engineering has requested Nyloplast profiles on other projects (Keswick), review proved helpful to design and Applicant. (FSP) Addressed, in this instance. Also, Applicant response: Item 48 below. See Item 48 for important clarification. 38. Wherever roof /yard drain storm conveyance systems pass beneath a retaining wall, show wall in profile view. Provide detail for lintel above these system pipes if deplh of cover beneath retaining wall is minimal. 39. Show and label ACSA utility easements consistent with easement plat under review. 40. Show /label or revise as necessary all private and public drainage easements, consistent with easement plat under review, consistent with Albemarle County Design Standards Manual easement diagram. Also, see item 2. above. 41. Label all easement widths. Ref. ACDSM, p. 15, easement width diagram. (FSP) As follow-up: Please confirm all drainage easement widths have been evaluated against ACDSM, p. 15, easement diagram. (Rev. 1) Addressed. Applicant: `Easement width chart has been included on Sheet 8 — Grading & Drainage Plan.' 42. Revise especially public drainage easement width at north corner of building 6, since depth to pipe trench floor of this 24` DIA pipe is — 18-11. No portion of any building may occupy any portion of a drainage easement. 43. Pipe 77 is in public easement and may not pass beneath a retaining wall Relocate pipe 77_ 44. Avoid roof /yard drain system pipe location beneath SWM retaining wall at the E end of the wet pond, conflict may be avoided by shifting pipe location —5'. (FSP) Addressed. Applicant response: `All the roof drain and storm pipe conflicts with the retaining walls have been removed. None of the pipes cross under the walls.' Sheets 8, 9 45. Label building 3. 46, Note: Roof /yard storm pipes enter structure numbers 24, 30, 64, 68, 2, 8, and 72. Show graphically, in profile view (sheets 16, 17). Include INV elevations requested elsewhere. 47. In parking west of building 4, provide grade (%) for surface runoff to Sir_ 20 to ensure positive drainage. 48. Label all roof /yard system inlets. Propose grading to ensure surface runoff reaches yard system inlets by proposing grade or providing spot elevations (grate INV) lower than adjacent grade. (FSP) Applicant response: `All the roof drains have been labeled on the plans, as requested. The elevation of the tie-in connections to the storm sewer manhole have been shown on the profiles. Inverts have been added to the yard drain system. Per the recent engineering's determination of roof drains, profile designs are not required for roof drains 8" in size or smaller.' As follow-up: Provide recent engineering determination, else do not rely on this response to request for design information for roof drains or yard inlet /pipe systems. Reviewer is unaware of this determination. If discussed March 5'", please share recollection. Engineering encountered yard /pipe installation issues on a recent project that may require developer to replace sections of pipe (prior to bond release). Reviewer is unaware of recent determination that would exempt a portion (in this case, critical portion) of drainage system from drainage review, or drainage design requirements. Notwithstanding recollections which may differ, Engineering does not request additional information /design revision in context of this review comment, for this project. Engineering Review Comments Page 9 of 12 49. Provide sealed engineering certification from Mfr. that Nyloplast® system elements meet VDOT drainage design specifications (equivalent load, deflection, strength rating, etc.). Settling is a major concern with design that proposes fill approaching 30' with entire pipe runs well above undisturbed ground, placed completely in fill. (Rev) Comment requests professional engineer's certification that a proposed material substitute for a VDOT standard be submitted. If there is settling in significant fill sections and pipe systems deflect or fail, review may be faulted for not requesting material certification of equivalent strength, resilience, etc. of proposed substitute to a VDOT reference standard (FSP) Withdrawn. Applicant response: `As discussed in the March 5' meeting, the storm pipe and plastic Nyloplast design is in accordance with the specifications and requirements.' 50. Show GR-2 along PIP (comment applies to other sheets, as well). Ensure GR-2 end treatments are shown, and labeled. Provide all relevant VDOT guardrail std. details (sheet 10).(FSP) Withdrawn. 51. Add additional existing contour labels N of PIP. (FSP) Addressed. 52. Revise proposed VDOT std allows 3.1 f ;.de W extend to the edge of PiP(Rev) Withdrawn. Guardrail removed along Peter Jefferson Parkway need not be removed. 53. Opposite Travelway A, north of PIP, eliminate asphalt walk line -work at entrance to MJH, since path does not exist beyond curbed limits of entrance to hospital. (Rev) It may be easier to discuss (during meeting). (FSP) Withdrawn. Review error. 54. Guardrail is required along the entire west side of Appleton Street, from PIP to entrance to SWM facility access, given unrecoverable slope beyond curb. Provide /label guardrail. 55. N of building 1, arrows indicate surface runoff, but proposed grading does not match direction of runoff. Provide grading that ensures runoff from slope between PIP and building 1 does not reach building 1, but is conveyed via swale to yard grate inlet/s on the N side of building 1. (FSP) Addressed. Applicant response: `The arrows north of Building # 1 are correct, there is positive drainage away from the building and positive drainage down the slope of the hill. These intersect to drain into the yard inlets, as shown.' 56. At wet pond, revise design to ensure pipe is aligned with riprap; otherwise, wet pond slope will erode. That is, direction of flow cannot change once it exits pipe. Ensure riprap and last pipe section align. Additional MH /pipe section may be required. Revise WPO201800027 to reflect change to site plan. Revise easement plat to reflect change to private drainage easement. 57. At both surface SWM facilities, provide L x W dimensions for riprap at pipe discharge to SWM facilities. 58. Reverse direction of 3:1 slope arrow, S of building 6. (Rev) Minor, slight revision. (FSP) Withdrawn. Review error. 59. Label 2:1 slopes W of Appleton Street near entrance to parking S of building 5. Provide note that these slopes will be planted with ground cover that does not require mowing (species hardier than grass. Note may ref WP0201800027). (FSP) Addressed. `Seeded meadow' mix to be used. See landscape plan. 60. Confirm Easement width is sufficient for proposed UG detention system depth, per ACDSM Easement diagram (Also, see item 2). Revise SWM facility easement plat (under review), if necessary. (FSP) Applicant response. `The underground detention pipes have been deleted from the plan design and are no longer needed.' As ollow-up: please see email to Collins Engineering, 5/2/2020 9:16 AM. (Rev. 1) Comment NA. VSMP /WPO201800027 Amendment 1 is approved (6/5/20). 61. Relocate proposed UG detention system access out of parking space. Revise WPO via letter to file, and w/ .PDF of plan sheet showing change to the WPO Plan. WPO Plan Amendment is not required for this change, alone. (FSP) Applicant response, `The underground detention pipes have been deleted from the plan design and are no longer needed.' As follow-up: please see email to Collins Engineering, 5/2/2020 9:16 AM. (Rev. 1) Comment NA. UG detention removed from design. 62. Label structure #53 (pipe), and #54 (inlet). (FSP) Not addressed. Comment persists. (Rev. 1) Addressed. 63. Reviseproposed retaining wall/s labels to include reference to handrail (`with handrail'). Virtually every retaining wall requires handrail 64. Label preserved steep slopes. 65. Continue driveway access line -work. Indicate limits of project relative to driveway access construction (i.e., tie to existing gravel road /drive. Avoid downslope conflicts)_ 66. If geogrid is needed for retaining walls, ensure tiered walls work with geogrid design. Avoid conflicts (landscaping /storm conveyance). (FSP) Persists to a degree. Also. item 31, above. Detailed retaining wall plan designs required. Applicant response: `The geogrid will not be in conflict with the landscaping and storm sewer. The geogrid will only extend 6' from the walls and will be outside of the pipes and structures. The geo-grid can be cut and molded around any of the storm sewer structures, as necessary.' Engineering Review Comments Page 10 of 12 (Rev. 1) Additional retaining wall comments possible. Please see item 31, above. (Rev. 2) Persists. Addressed pending review of pending revised HC Engineering revised retaining wall design plans. Applicant: `Please see the response above to comment 3 La.' (Rev. 3a) Addressed. Sheet 10 67_ Provide the following and additional relevant details: a. GR-2, b. CG-12," c. Roll Lace curb, d. Dumpster pad, e. Primitive trail, f Nyloplast details, (FSP) Comment persists. Please provide Nyloplast ® details. (Rev. 1) Persists. Also, see item 74, below. (Rev. 2) Addressed. Applicant response: `Sheet 11, in the middle left portion of the page, shows a standard detail for Nyloplast Drain Basins (yard inlets). Per note 41 in the lower left portion of this detail, this design applies to grate inlets ranging from 12"-30" and is applicable to this project. Additionally, sheet 17 was updated to include `installation requirements for ADS Yard/Roof drain system'. In the June 18' phone conversation, it was determined adding these notes to sheet 17 for the private/smaller roof and yard drains exceed the requirements to address this comment. g. Drive Access section, (FSP) Comment persists. See Driveway Access, lower edge sheet 5. (Rev. 1) Partially addressed. As follow-up: Confirm driveway access to receive: 2" SM-9.5 surface course, 3" BM-25 intermediate course, 5" 21-A base course (stone). This may be unintentional. (Rev. 2) Addressed. Applicant response: `The two asphalt paving details in question, located on sheet 10 in the center portion of the page, were combined and are no longer redundant. The consolidated detail now reads `main travelways' and `drive aisles'. The 2"/3"/5" layers are correctly shown.' h. Pipe lintel detail (at walls), (FSP) Withdrawn. Design revised, pipes no longer pass beneath retaining walls. i. Pavement section based on ADT, j_ Reconcile ions with plan view. Note, for example 7' on -street parking width is<9'min _required _ Rel_18-4.12.16.c.2. k. Ensure typical travelway sections are accurate, and match sheets 4, S. Revise typical travelway sections to show CG-6 rather than CG-2 (18-4.12_ IS.g_)_ 1. Please ref. VDOT Road Design Manual B(1)-7 Table 1, Min. travel width, parking 1-side. * Also: CG-12 detectable surface with radial curb. (FSP) Persists at Item 12. As follow-up: Revise CG-12 in layout views to reflect VDOT Std, for detectable surface in radial curb section. (Rev. 1) Addressed. 68. Sheet 11: Provide VDOT pipe bedding std. details. Sheets 12, 13: 69. Show /label intersection sight lines on these plan sheets, all travelway intersections (18-4.12.15.d). Avoid landscape/sight line conflicts. (FSP) Partially addressed. Applicant response: `The intersection sight distances have been shown on the layout sheet and landscaping sheet, as requested. The note about the pruning of the landscaping has been added to the sheet.' As follow-up: Please show sight distance lines on Landscaping Plan, sheet 12. (Rev. 1) Addressed. 70. Avoid landscape canopy species (extensive root systems) - storm system conflicts (Str.# /location), at: a. Str. #64, 24, 60B, U, (FSP) Partially addressed. Conflict persists at Str. 64, 6013; resolved at 24. No structure 88. (Rev. 1) Addressed. b. relocate /remove 3 canopy trees directly opposite Moraga St. entrance, (FSP) Partially addressed. Partial conflict persists. (Rev. 1) Addressed. c. roof /yard system E of building 3 label and W of building 4 label (canopy trees coincident with Nyloplast proposed pipe location), and N of N comer of clubhouse, (FSP) Partially addressed. Conflict persists W of building 4 label. (Rev. 1) Addressed. d. roof /yard system E of building 3, —1/3 building length N of SE comer of building, e. remove trees from SV Engineering Review Comments Page 11 of 12 Sheets 16, 17 71. Recommend Avoid proposed pipe grade < 0.6%. Pipe cannot be removed /replaced with this design without prohibitive expense. Design of 0.50, 0.52, 0.53% cannot -be approved, but invites risk. This design imperils CO unless any deficiency of pipe installation (slope, elevation, deformation, deflection) can be and is addressed. (Rev) Revised to a recommendation. See pg. L, above. (FSP) Applicant response: `Comment removed, pipes may be installed per the engineering minimum which is 0.5%' Design does not reflect Engineering recommendation to increase slope slightly to provide tolerance for error of construction. 72. WgUOSt ...00'iRg With l4HgiROO^^^'^ di8GW,^ rRev) Withdrawn. Up to 16' cover permissible with PE, 24" DIA pipe. Design at UG SWM — Outfall, pipe 77, Sta. 1+00 approaches max. depth, but is acceptable. [ Rev. I image removed with Rev. 2 comments. ] 73. _RoL-a. Limits will apply. HDPE impefils design sinee it may defeFfn, eellapse, efe., while RG12will . Rev) Applicant response: `This comment needs to be removed. This is not accurate and the system is a private drainage system.' Withdrawn /review error. See item 72. 74. HDPE Note references detail. sheet 17. No HDPE pipe bedding detail is provided on sheet 17. (FSP) Comment persists. (Rev. 1) Not addressed. Applicant: `Sheet reference updated to Sheet 11, where bedding detail is located.' Nyloplast ® Inserta-Tee ® detail does not indicate stone bedding depth, compaction, minimum cover requirements, etc, in any detail. (Rev. 2) Withdrawn /review error. Detail provided but overlooked. 75. Provide HDPE pipe bedding detail, (FSP) Comment persists. Please provide ref to sheet with this detail. (Rev. 1) Not addressed. Also, item 74. (Rev. 2) Withdrawn /error. Detail provided but overlooked. 76. Revise profiles per comments, elsewhere (yard/roof system INV, provide roof /yard system profiles, etc.) (Rev) Please see item 37, above. (FSP) Withdrawn. Note (future reference): Important clarification at Item 48, above. 77. Provide and label Y:" steel plate for stepped vertical drops within MHs. Ref. VDOT Drainage Manual, 9.4.8.7 (p. 9-37). Label each MH str. that require a Y:" steel plate floor. (FSP) Comment persists. For example: see sheet 17, Str. 62 and 46. (Rev. 1) Addressed. 78. Label retaining walls in storm profiles. (FSP) Applicant response: `All wall crossings with the storm sewer have been removed.' 79. Ensure retaining wall design works with proximate storm elements (MIL for example). (FSP) Comment persists. Also, Item 31, above. Applicant response: `The comment is acknowledged. The wall design will take into account all existing and proposed infrastructure.' (Rev. 1) Persists. Applicant: `Acknowledged.' (Rev. 2) Persists. Applicant: `The wall design will take into account all existing and proposed infrastructure. Please see the response above to comment 3 La.' (Rev. 3a) Addressed. 80. Specify geotechnical reports of daily inspection of pipe /DI installation operations in fill sections with more than minimal fill beneath storm elements, i.e., for pipe runs installed over significant fill (Str-24 — Str-6, for example). Propose daily inspection with qualified geotechnical reports to be submitted to Albemarle County for verification of backfill (% moisture, content /contamination, compaction, dry density, etc.) (FSP): Comment persists. Please indicate where highlight items (geotechnical specifications /inspection /reporting Notes) occur on plans. Applicant response: `This comment is acknowledged.' As ollow-up: Engineering requests Notes on sheets 16, 17 (similar to ACSA General Water and Sewer Conditions, sheet that reflect request for highlight information (to appear on plans). (Rev. 1) Addressed. 81. Sheet 19: Ensure Fisher Street profile is smooth, VC at each grade transition. (FSP) Comment appears to persist; see Sta. 11+70 (f), Fisher Street. (Rev. 1) Addressed. 82. Sheet 22: Provide sight distance (right) at Int. Appleton Street and PJP. (FSP) Not addressed. Provide sight distance (right) at Int. Arguello Street and PIP. (Rev. 1) Withdrawn. Review error. Applicant: `The median along Peter Jefferson Parkway blocks traffic leaving via Arguello Street from taking a left turn. This is a right-in/right-out entrance, therefore, sight distances aren't needed for a left turn out of the entrance.' Sheets 23, 24 83. Label all design tables (LD-204, LD-229, etc.). Use VDOT designations /ref drainage manual. Engineering Review Comments Page 12 of 12 84. Provide design calculations for Nyloplast roof /yard systems. (FSP) Partially addressed. As ollow-up: Table 9, sheet 24, does not appear to provide pipe capacity. Revise table to provide pipe capacity for all listed drainage pipes. (Rev. 1) Addressed. Ref. sheet 24. 85.pecommendogwm«*-rr,Ioplast (g) s�-,otem r�. 0.37 A, PA rvn i re (Rev) A recommendation, (FSP) As follow-up: See request for capacities of pipes in Table 9 (Item 84). Applicant response: `The nyloplast is adequate to handle this area.' Additional comments possible, once table revised. (Rev. 1) As follow-up: Please revise structure type, YD-1C, so that all 4 descriptions reference 24". (Rev. 2) Addressed. 86. New: Review and respond to FSP- /WPO-related email sent to Collins Engineering, 5/2/2020 9:16 AM. Also, see CE response, email received 5/2/2020 10:56 AM. (Rev. 1) Withdrawn, WPO201800027 Amendment 1 was approved 5 Jun 2020. 87. New: Orient sheets to landscape (rotate counterclockwise, as needed), to aid review (sheets 5B, 12A, 15, 22, etc.). (Rev. 2) Withdrawn per discussion 18-Jun (telecon). Please feel free to call if any questions: 434.296-5832-x3069. Thank you SDP2020-00023 Martha Jefferson Hospital Presidio Apts-FSP 081020rev3a Sample: HC RW (020720 Retaining Wall plan) v. FSP (vi 8/420 link); minor inconsistencies (circled, blue) visible in 2/7/20 HC RW plan v. FSP are resolved with 7/920 HC RW print plan (PE -seal date 7/1020). Engineering has No objection to the ESP.