Loading...
HomeMy WebLinkAboutSDP202000046 Review Comments Minor Amendment 2020-08-14County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 434-296-5832 Memorandum To: Scott Schiller From: Christopher Perez, Senior Planner Division: Planning Date: August 14, 2020 Subiect: SDP202000046 Moores Creek Wastewater Treatment Plant (Liektine Plan) - Minor Amendment The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following comments have been satisfactorily addressed (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [32.5.1(c), 32.7.8, 4.71 Lighting. Increase the width and boldness of all property lines so they are easily distinguishable from other lines on the plan. Rev 1. Comment addressed. 2. [32.5.2(n)] Outdoor Lighting. On the plan provide cut sheets for all proposed light fixtures. Ensure they are clearly labeled. Rev 1. Comment addressed. 3. [32.5.2(a), 32.7.8, 4.71 Lighting. On the cover sheet clearly label which parcels are included in the lighting plan. It is not clear which tax map parcels are part of the site plan amendment. Rev 1. Comment addressed. 4. [32.7.8, 4.71 Lighting. Utilize a Light Loss Factor (LLF) of 1 for the revised lighting plan. List the LLF utilized on the plan. Rev1. Comment addressed. 5. [32.7.8, 4.71 Lighting. Identify and label the existing and the proposed light poles and light fixtures. Rev 1. Comment addressed. 6. [32.5.21 On the cover sheet provide the following "SDP202000046 Moores Creek Wastewater Treatment Plant (Lighting Plan) - Minor Amendment". Rev 1. Comment addressed. 7. [32.4.3.6, 32.4.3.21 The site plan shall not be approved until all other reviewers have approved the plan. Their comments are referenced below and attached. Rev 1. Comment still relevant. 8. [32.7.8, 4.71 Lighting. The photometric plan is not legible. The spillover numbers cannot be read. Resubmit this plan with legible spillover numbers. 9. [32.7.8, 4.71 Lighting. The cutsheets are not all legible. Resubmit this plan with legible cutsheets. Additionally, staff was unable to locate cutsheets for the following fixtures: VFX-L, W4250 MH00, PWM, PXDW WDU. Ensure cutsheets for these are provided. ARB — Khris Taggart Review comments to be forwarded once received. Zoning — Lisa Green Review comments to be forwarded once received. Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle. The Code is kept up to date by the County Attorney's office. The Code may found on the County Attorney's website which may be found under "Departments and Services" at Albemarle.org. In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code if the developer fails to submit a revised final site plan to address all of the requirements within six (6) months after the date of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. If you have any questions about the comments please feel free to contact me. Please contact Christopher Perez in the Planning Division by using cperezgalbemarle.org or 434-296-5832 ext. 3443 for further information.