Loading...
HomeMy WebLinkAboutSDP201900062 Plan - Revision 2020-08-14IN SITE DATA OWNER: HYDRAULIC & GEORGETOWN LLC 400 LOCUST AVENUE, SUITE 3 CHARLOTTESVILLE, VA 22902 FINAL SITE PLAN DEVELOPER: BMC HOLDINGS GROUP LLC 400 LOCUST AVE, SUITE 3 CHARLOTTESVILLE, VA 22902 PLAN PREPARER: ROUDABUSH, GALE, & ASSOCIATES, INC. G ORG TOWN 999 SECOND ST. SEHYD RAU I C CHARLOTTESVILLE, VA 22902 (434)-977-0205 TAX MAP PARCEL No: 060FO-00-00-00300 JACK JOUETT MAGISTERIAL DISTRICT PARCEL AREA: 1.05 ACRES ZONING: NEIGHBORHOOD MODEL DISTRICT. PARCEL IS SUBJECT TO ZMA2006-14 WITH ASSOCIATED PROFFERS AND CODE OF DEVELOPMENT- AIRPORT OVERLAY AND ENTRANCE CORRIDOR OVERLAY DISTRICTS PROPOSED USE. PROFESSIONAL OFFICES BUILDING AREA: 16,815 GROSS SF, MAXIMUM ALLOWED 14,289 GROSS SF, PROPOSED (INCL. PARKING LEVEL) BUILDING HEIGHT ALLOWED: 2 STORIES: 50' MEASURED FROM FRONT FACADE 3 STORIES: 60' MEASURED AT THE BACK TO INCLUDE BASEMENT BUILDING HEIGHT PROPOSED: FRONT 32' MEASURED FROM FINISHED FLOOR TO PARAPET PARKING SETBACK: 10' MINIMUM BUILDING SETBACKS: (IN ACCORDANCE WITH THE GENERAL DEVELOPMENT PLAN) (MINIMUM) FRONT SETBACKS FROM BUILDING CORNERS: 9.63' & 13.47' FRONT SETBACKS FROM CENTER OF BUILDING: 15.22' & 21.85, BUILDING SETBACKS FROM THE RA ZONING: 47.50' AREA SUMMARIES: TOTAL BUILDING COVERAGE = 6,765 SF (157) TOTAL IMPERVIOUS COVERAGE (INCL BUILDING) = 20,765 SF (459) TOTAL OPEN SPACE = 24,973 SF (559) MAGISTERIAL DISTRICT.- JACK JOUETT MAGISTERIAL DISTRICT WATERSHED: IVY CREEK (A WATER SUPPLY PROTECTION AREA) BOUNDARY SOURCE: SUBDIVISION PLAT, LOT 1, "GEORGETOWN GREEN" PREPARED BY W.S. ROUDABUSH, DATED JUNE 20, 1967, RECORDED AT DB 440 PG 93. ALBEMARLE COUNTY, VIRGINIA TOPOGRAPHY.- TAKEN FROM GENERAL DEVELOPMENT PLAN BY DOMINION DEVELOPMENT RESOURCES, LLC (2006); TREE SURVEY BY ROUDABUSH, GALE & ASSOCIATES, ✓ANUARY 2019, WATERLINE LOCATION CHECK BY ROUDABUSH, GALE & ASSOCIATES, SEPTEMBER 2019. BENCHMARK: TRAFFIC BOX 614.79. TAKEN FROM GENERAL DEVELOPMENT PLAN BY DOMINION DEVELOPMENT RESOURCES, LLC (2006) DATUM: HORZ.: NA VD 88 VERT.: NAD83 FLOODPLAIN: THIS PROJECT IS LOCATED WITHIN "ZONE X" AS SHOWN ON FLOOD INSURANCE RATE MAP. COMMUNITY PANEL NUMBER 510003C 0279 D. EFFECTIVE DATE: FEBRUARY 4. 2005. PARKING REQUIRED: PER GENERAL DEVELOPMENT PLAN, 1 SPACE PER 200 SF NET LEASABLE AREA = 9,3761200 = 47 SPACES PARKING PROVIDED: 50 PARKING SPACES TOTAL 2 ADA VAN ACCESSIBLE SPACES** *3 SPACES RESERVED FOR IMP 60E-1 PER DB 1591 PG 160 **ACCESSIBLE PARKING SPACES AND ACCESS ISLES SHALL NOT HAVE A SURFACE SLOPE GREATER THAN 1: 48. ACCESS ISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACE THEY SERVE RETAINING WALLS: RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE AN STAMPED ENGINEERED DESIGN. PLEASE SEE RETAINING WALL DESIGN BY OTHERS UNDER SEPARATE COVER. LANDSCAPING: SEE LANDSCAPING PLAN SHEET LIGHTING: EACH OUTDOOR LUMINARIES EQUIPPED WITH A LAMP THAT EMITS 3,000 OR MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINARIES AND SHALL BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING RESIDENTIAL DISTRICTS AND FROM ADJACENT ROADS. AMENITY AREA REQUIRED - 5,227 SF (11.07.) PROVIDED - 17,785 SF (38.99) NO EVIDENCE OF A BURIAL SITE WAS FOUND ON SUBJECT PARCEL. NO STREAM BUFFER(S) ARE PRESENT ON THE SUBJECT PARCEL. THE SUBJECT PROPERTY IS NOT LOCATED WITHIN AN AGRICULTURAL -FORESTAL DISTRICT. THE SUBJECT PROPERTY IS LOCATED WITHIN THE JURISDICTIONAL AREA FOR PUBLIC WATER AND SEWER. GENERAL CONSTRUCTION NOTES PLAN NOTES 1. THE OWNER WILL DESIGNATE A PROJECT MANAGER TO ACT AS OWNER'S REPRESENTATIVE DURING THIS PROJECT. CONTRACTOR SHALL REPORT DIRECTLY TO THIS PROJECT MANAGER UNLESS OTHERWISE DIRECTED. 2. THE DESIGNER HAS CONDUCTED NO STUDIES DESIGNED TO DISCOVER THE PRESENCE OF ANY HAZARDOUS SUBSTANCES ON THIS PROPERTY AND ASSUMES NO RESPONSIBILITY OR LIABILITY RESULTING FROM THE PRESENCE ON ANY SUCH SUBSTANCE. 3. THE CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR THIS WORK AND PAY ALL ASSOCIATED FEES. THIS INCLUDES ALL NECESSARY PERMITS, INSPECTIONS, BONDS, AND OTHER APPROVAL RELATED ITEMS IN ACCORDANCE WITH THESE PLANS AS WELL AS LOCAL, STATE, AND FEDERAL POLICIES. 4. PAVED OR RIP RAP DITCH MAY BE REQUIRED WHEN, IN THE OPINION OF THE RESIDENT ENGINEER OR HIS DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 5. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES, LATEST EDITION, AND SHALL BE PROVIDED BY THE CONTRACTOR. 6. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). 7.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE VDOT ROAD AND BRIDGE STANDARDS (LATEST EDITION) AND THE VDOT ROAD AND BRIDGE SPECIFICATIONS (LATEST EDITION). EARTHWORK, DRAINAGE, & SITE CONDITIONS 1. EXCEPT AS OTHERWISE SHOWN ON THE PLANS, ALL CUTS AND FILLS SHALL MATCH EXISTING SLOPES OR BE NO GREATER THAN 2:1. 2. UNLESS OTHERWISE NOTED ON THE PLANS OR IN THE SPECIFICATIONS, ALL FILL MATERIALS SHALL BE COMPACTED TO 95% OF THEORETICAL MAXIMUM DENSITY AS DETERMINED BY AASHTO T-99 METHOD A, WITHIN PLUS OR MINUS 2% OF OPTIMUM MOISTURE, FOR THE FULL WIDTH AND DEPTH OF THE FILL. 3. ALL GRADING AND IMPROVEMENTS TO BE CONFINED TO THE PROJECT AREA UNLESS OTHERWISE INDICATED. 4. ALL MATERIALS AND INSTALLATION DETAILS SHALL CONFORM TO APPLICABLE LOCAL ORDINANCES AND VDOT ROAD & BRIDGE STANDARDS (LATEST EDITION) UNLESS OTHERWISE STATED WITHIN THE PLANS.. 5. ANY UNUSUAL OR UNANTICIPATED SUBSURFACE CONDITIONS SHALL BE IMMEDIATELY REPORTED TO THE ENGINEER. 6. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND LOCATIONS PRIOR TO BEGINNING WORK, AND IMMEDIATELY NOTIFY THE PROJECT MANAGER IN THE EVENT THERE ARE ANY DISCREPANCIES BETWEEN SUCH CONDITIONS AND THOSE SHOWN ON THE PLANS AND SPECIFICATIONS. 7.IN THE EVENT THAT GRADING AS SHOWN ON THE PLANS IS NOT FEASIBLE, CONTRACTOR SHALL ADVISE THE PROJECT MANAGER AND ENGINEER BEFORE FINAL GRADING COMPLETION FOR ADVICE AND CONSENT. UTILITES & DRAINAGE SYSTEMS UTILITIES 1. ANY DAMAGE TO EXISTING UTILITIES CAUSED BY CONTRACTOR OR ITS SUBCONTRACTORS SHALL BE CONTRACTOR'S SOLE RESPONSIBILITY AND REPAIRED AT CONTRACTOR'S EXPENSE. 2. THESE PLANS DO NOT GUARANTEE THE EXISTENCE, NON-EXISTENCE OR LOCATION OF UTILITIES. CONTRACTOR SHALL VERIFY THE EXISTENCE AND LOCATION OR THE NON-EXISTENCE OF UTILITIES. AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION OR CONSTRUCTION, CONTRACTOR SHALL NOTIFY MISS UTILITY (1-800-552-7001) AND/OR THE RESPECTIVE UTILITY COMPANIES FOR GAS, WATER, SEWER, POWER, PHONE AND CABLE. CONTRACTOR SHALL TIMELY ARRANGE TO HAVE THE VARIOUS UTILITIES LOCATED, AND TO HAVE THEM REMOVED OR RELOCATED, OR TO DETERMINE THE METHOD OF PROTECTION ACCEPTABLE TO THE RESPECTIVE OWNER, IF THE METHOD OF PROTECTION IS NOT OTHERWISE SPECIFIED. CONTRACTOR SHALL CONDUCT ITS WORK IN THE VICINITY OF EXISTING UTILITIES IN ACCORDANCE WITH THE RESPECTIVE UTILITY'S RULES AND REGULATIONS. ANY COST INCURRED FOR REMOVING, RELOCATING OR PROTECTING UTILITIES SHALL BE BORNE BY CONTRACTOR , UNLESS INDICATED OTHERWISE. CONTRACTOR SDP=2019=00062 VICINITY MAP SCALE: 1'=1000 FEET THIS PARCEL IS SUBJECT TO ZMA2006-14 WITH ASSOCIATED PROFFERS AND CODE DEVELOPMENT. SHEET INDEX SHEET 1---------- COVER SHEET SHEET 2---------- EXISTING CONDITIONS & DEMOLITION PLAN SHEET 3---------- SITE PLAN & LAYOUT PLAN SHEET 4---------- UTILITY PLAN SHEET 5---------- WATERLINE PROFILES & DETAILS SHEET 6---------- GRADING PLAN SHEET 7---------- SIGHT DISTANCE PLAN & PROFILES SHEET 8---------- TRAFFIC CALCULATIONS & DETAILS SHEET 9---------- TRAFFIC CONTROL PLAN SHEET 10-------- LANDSCAPE PLAN, NOTES AND DETAILS SHEET 11-------- PHOTOMETRIC PLAN & DETAILS SHEET 12-------- PHOTOMETRIC PLAN & DETAILS SHEET 13-------- CONSTRUCTION DETAILS LEGEND EXISTING INTERMEDIATE CONTOUR - -332 - - - - EXISTING INDEX CONTOUR - 300- - PROPOSED CONTOUR 20 EXISTING EDGE OF PAVEMENT EX. EP PROPOSED EDGE OF PAVEMENT EP EXISTING CURB AND GUTTER EX. C&G PROPOSED CURB AND GUTTER CG-6 TRANSITION FROM CG-6 ROLL-TOP CGb ROLL-TOP EX. 15" RCP EXISTING STORM SEWER I I niiiiiilllf I I � 15" RCP PROPOSED STORM SEWER t 1 I= I I It EXISTING SANITARY SEWER - S S S PROPOSED SANITARY SEWER -S S S - PROPERTY LINE EASEMENT LINE CENTERLINE - LIMITS OF CLEARING AND/OR GRADING ���������������■ EXISTING SPOT ELEVATION + 12.0 PROPOSED SPOT ELEVATION +12.0 EXISTING TREE DRIP LINE EXISTING TREE EX. 15' OAK PROPOSED TREE OAK SHALL EXCAVATE TO LOCATE BURIED UTILITIES FAR ENOUGH IN ADVANCE OF ITS WORK TO ALLOW FOR HORIZONTAL AND /OR VERTICAL ADJUSTMENTS TO ITS WORK AND/OR THE UTILITIES. NO ADJUSTMENT IN COMPENSATION OR SCHEDULE WILL BE ALLOWED FOR DELAYS RESULTING FROM CONTRACTOR'S FAILURE TO CONTACT AND COORDINATE WITH UTILITIES. 3. WHEN THE WORK CROSSES EXISTING UTILITIES, THE EXISTING UTILITIES SHALL BE ADEQUATELY SUPPORTED AND PROTECTED FROM DAMAGE DUE TO THE WORK. ALL METHODS FOR SUPPORTING AND MAINTAINING THE EXISTING UTILITIES SHALL BE APPROVED BY THE RESPECTIVE UTILITY COMPANY AND/OR THE ENGINEER. CONTRACTOR SHALL EXERCISE CARE TO INSURE THAT THE GRADE AND ALIGNMENT OF EXISTING UTILITIES ARE MAINTAINED AND THAT NO JOINTS OR CONNECTIONS ARE DISPLACED. BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED TO PREVENT FUTURE DAMAGE OR SETTLEMENT TO EXISTING UTILITIES. ANY UTILITIES REMOVED AS PART OF THE WORK AND NOT INDICATED TO BE REMOVED OR ABANDONED SHALL BE RESTORED USING MATERIALS AND INSTALLATION EQUAL TO THE UTILITY'S STANDARDS. 4. CONTRACTOR SHALL NOTIFY LANDOWNERS, TENANTS AND THE PROJECT MANAGER PRIOR TO THE INTERRUPTION OF ANY SERVICES. SERVICE INTERRUPTIONS SHALL BE KEPT TO A MINIMUM AND SHALL ONLY OCCUR WITH THE KNOWLEDGE AND PERMISSION OF THE SERVICE'S OWNER OR AUTHORITY. 5.THE ADJUSTMENT OF ALL MANHOLE TOPS, WATER VALVE BOXES, GAS VALVE BOXES AND WATER METER BOXES SHALL BE THE RESPONSIBILITY OF CONTRACTOR. 6. ALL WATER METER, VALVES AND FIRE HYDRANT ADJUSTMENTS/RELOCATIONS SHALL BE PERFORMED BY THE CONTRACTOR. CONTRACTOR SHALL KEEP A "REDLINE" SET OF PLANS DOCUMENTING ALL SUCH AS -BUILT REVISIONS. TALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. DRAINAGE SYSTEMS 1. CONTRACTOR SHALL EXERCISE CARE, ESPECIALLY AT INTERSECTIONS AND GUTTER LINES, TO PROVIDE POSITIVE DRAINAGE. ANY AREAS WHERE WATER IS IMPOUNDED SHALL BE CORRECTED BY CONTRACTOR AT NO ADDITIONAL COST. POSITIVE DRAINAGE OF ALL ROADWAY AREAS TO THE STORM DRAIN INLETS OR OTHER ACCEPTABLE DRAINAGE CHANNELS AS NOTED ON THE PLANS IS REQUIRED. 2. CONTRACTOR SHALL MAINTAIN EXISTING STREAMS, DITCHES, DRAINAGE STRUCTURES, CULVERTS AND FLOWS AT ALL TIMES DURING THE WORK. CONTRACTOR SHALL PAY FOR ALL PERSONAL INJURY AND PROPERTY DAMAGE WHICH MAY OCCUR AS A RESULT OF FAILING TO MAINTAIN ADEQUATE DRAINAGE. 3. ALL PIPES, DI'S AND OTHER STRUCTURES SHALL BE INSPECTED BY THE PROJECT MANAGER BEFORE BEING BACKFILLED OR BURIED. THE PROJECT MANAGER MAY REQUIRE CONTRACTOR, AT NO ADDITIONAL COST, TO UNCOVER AND RE-COVER SUCH STRUCTURES IF THEY HAVE BEEN BACKFILLED OR BURIED WITHOUT SUCH INSPECTION. 4. ALL CATCH BASINS ENCOMPASSED WITHIN NEW CONSTRUCTION SHALL BE CONVERTED TO DROP INLETS. 5. REMOVED PIPE SHALL BE THE PROPERTY OF CONTRACTOR UNLESS NEGOTIATED OTHERWISE BEFORE PROJECT BIDDING; AND IF NOT SALVAGED FOR RE -USE, SHALL BE DISPOSED OF LAWFULLY. 6. ALL STORM SEWER PIPE AND DROP INLETS SHALL BE CLEARED OF DEBRIS AND ERODED MATERIAL PRIOR TO FINAL ACCEPTANCE. 7. ALL STORM SEWER PIPE JOINTS SHALL BE SEATED AND SEALED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. 8. ALL EXISTING ROOF DRAINS AND OTHER DRAINAGE CONDUIT BLOCKED OR DISRUPTED FROM THEIR PRE -CONSTRUCTION DRAINAGE PATTERNS SHALL BE SHORTENED, EXTENDED OR OTHERWISE ROUTED USING MATERIALS APPROVED BY THE ENGINEER, AND IN SUCH A WAY THAT THE NEW DRAINAGE PATTERNS ARE ACCEPTABLE TO ENGINEER AND THE PROJECT MANAGER. 9.ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. EXISTING WATERLINE PROPOSED WATERLINE EXISTING FIRE HYDRANT } PROPOSED FIRE HYDRANT } EXISTING WATER VALVE F) PROPOSED WATER VALVE ---- &-• PROPOSED WATER METER EXISTING REDUCER w- PROPOSED REDUCER •10 w HANDICAP RAMP (CG-12) DENOTES LOCATION OF STD. VDOT CG-12 AND/OR JURISDICTIONAL STANDARD RAMP CONSTRUCTION PARKING INDICATOR 2 INDICATES THE NUMBER OF TYPICAL PARKING SPACES BENCHMARK e VEHICLES PER DAY COUNT 1,234 VOID PROPOSED STREET NAME SIGN + EXISTING SIGN -o- PROPOSED SIGN -� APPROVALS DEPARTMENT OF COMMUNITY DEVELOPMENT DATE PLANNING / ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VA. DEPARTMENT OF TRANSPORTATION CONTRACTOR'S RECORD DRAWING CERTIFICATION STATEMENT: (SEE SHEET 9 FOR RECORD DRAWING REQUIREMENTS) THIS HAND MARKED SET OF DRAWINGS HAS BEEN "REDLINED" TO PROVIDE AN ACCURATE DETAILED RECORD OF ANY SUBSTANTIVE CHANGES TO THE APPROVED DESIGN DRAWINGS. ANY ITEMS NOT "REDLINED" ON THIS PLAN SET OR SUBSEQUENT PAGES SHOULD BE CONSIDERED TO BE "CONSTRUCTED IN ACCORDANCE WITH THE DESIGN AS SHOWN" NAME, TITLE FOR: DA TE CONTRACTOR) A U 6 m W ^ COo z Z59N O o(0 gY> 02 J Q 01 2 J U J = O U Q m W Q W [ O 7 w UQ MQ for JZ vU ZD V o > N x Wa T/1 O z m �> o a aw N W N W Q w Z J > O U U) J a J _ co O/ o w W a O 0 W Q �Q rn U z 0 a N 0 z z z z 00 z z z z cc 0 0 W � � Q N M � � n 0 0 C5 o���P1,T H O p `4111 o .- U 9 Jimmy L. Taggart Lic. No. 4 A''`'o,, 07/311/2020 11'22841 w� ES810NAL EEO U_ J Q Z��53 CE QO w> D_ = a � w W d Q x �z0W a J O a C) z I­_o Il `w� Q Z V cr O O W 0 DATE: 10-25-2019 SCALE: NA JOB: 19.0125 SDP-2019-00062 SHEET: � OF 13 \ I 1 \ \ I _J--- \\ I _ (\1 II L I END SIDEWALK/CURB DEMO DASHED LINE INDICATES EXTENTS OF SAW CUT & MILLING OF PAVEMENT WHERE - - - 1 APPLICABLE. PROPOSED PAVEMENT WIDENING / IN ACCORDANCE WITH VDOT STANDARDS. I II CRITICAL SLOPE PER ALBEMARLE COUNTY GIS -SLOPES BOUNDARY CURVE TABLE Curve Length Radius Delta Tangent Chord Chord Bearing C6 16.68' 235.00' 4'04'03" 8.35' 16.68' N 00'37'30" E C7 64.64' 265.00' 13'58'33" 32.48' 64.48' S 04'19'46" E C11 97.24' 1696.02' 3.17'06" 48.63' 97.23' S 12.57'35" E C13 22.01' 60.00' 21'01'16" 11.13' 21.89' S 04'21'31" E C17 23.84' 60.00' 22'45'58" 12.08' 23.68' S 27'29'12" W GREATER THEN 25% APPROXIMATELY 5 860 SF TO BE \ DISTURBED. NO DISTURBANCE TO BE DONE IN I \ II I� I / I�u I LEGEND: PRESERVATION AREA 1 \ I II I / Q> wV I I I I \ \ \ \ \ \ \ II EXISTING CURB o I. 11 I I I \\ ❑ GIS CRITICAL SLOPES >25% TMP 60E-1 �~ wn '—o \ EXISTING SANIT RY \ DYNAMIC INVESTMEN oN I I 1 \ \ SEWER & EASEMI T CAPITAL ENTERPRIS �o �� \ so \ \ �n 1 1 \ PRESERVATION AREA ZONED: C-1 \ USE: OFFICE BUIL iNG♦♦ ♦ ♦ ♦ i XC° I I , EXI TING MAN OLE T01 BE LOW RED TO --- \ 1 \ I `� wo \ CONSERVATION AREA - - - � � I � �� �• � FINI HED PAVE ENT GRADE � 1 1 dl I 11 ♦ ♦j / / I<. 1 I 1 A loop h' ~ ENt Nk / ♦,' ♦' ♦ / / - 1-8,_ / / I II U , XISTINGISIDEWALK & CURB TO BE \ •• • • • •• SOIL BOUNDARY SEt� N ♦ I .►�` (�� BOUNDARY LINE TABLE Line Direction Length L1 S 1C44'06" E 14.39' L2 N 7742'45" W 4.50' L3 S 15'21'39" W 10.20' L4 S 8218'27" E 5.22' L5 S 38'50'59" W 79.63' L6 N 64.12'41" W 166.59' L7 N 10.52'19" E 210.70' L8 N 80.05'19" E 143.39' o 91$ �i ♦ ', / / / I I EMOVED FOR ENTRANCE CONSTfjUCTIOjV \ \--_'D SMH 1 I , 7 : i _ I 1 1 1 11 `` \ s \ 6"PRD / I / i / / ,-/ I as .. I 1 11 20 1 0 20 40 0 + I 10"CHRY ( hr r 4C is i I .1 t ,PL ; \` / I I I 11 SCA \ ' N r' 1 4NPG,: EASEEN PROPOSED } I° I 1 11 1-zo ` ^.: EX 15 DRA \. II ; + ' ' SITE I 'all CRITICAL SLOP PER AL RLE CO 4''OAKX� I Poj F'% s ENTRANCE I I I B A O NT GISI 1 I ® I Icetreeswithin the Conservation Areas snailne _ � PROPOSED -rI 0 K POP-- laced must be in excess of 12" dbh and shall be I I 5'I s r — — — _ ` SANITARY �, 1 1 � :less then 2.5" dbh, as determined by the County's ti ♦� CC)NNECTION 36" OpK I/, + I 1 \ I`t i 10;0A \\ 112 0 __ 1 1 / ! ; I 1 I II 24"PINE 8"MPL 1 I r "''J 8"C R+ 8 I 11"PO+� \2"POP 18"pervisws 1 I 24"PINE I 1 GI 1, � �1 I 1 8"oAl<r_� 30'i'OII / TMP 60E-3 18"PINE 18"POP I 1.05 ACRES 8"OAK ! sr Fi;P')P �. 9"PG 12"PINE �I s - w_MIN. 9.63' BUILDING CORNER 1 8VIN I� r f I 1 = / \ I ® I v) o„ r t, i 1 a w \ / / ® I 1 10"POP SPIN I \ +l I �P +Q _ i1 if + SETBACK �1 1� -! l 1 + I 0) iS H- �1 ZMA2006-14 m I a°. \ / / / 24 P P 1 =, Js21"P(ya I co I \ i I 1 INEI`) s' ,�, 30"POP + 12"b\K I 10' OPi/ v� 15'POP \I I10"MPL + 1 M 24"PINE F' r �.. W i CA 1 _ PRES AT 1N \ �\ G I \ I \\ <\ II \\ 1 I 1 O"Pop I \ a�En I / 12 Loc \ II ® ; \ \ \ \ ,� I 1 \ \ (SOIL E 0 MR 15'CH Y "SASS �- A /--------- \ \ \ \ 10"CHRY I �i a 20"MPL \ wl \ :. �\ z Q I 1 �(' \ ( / — \ \ 1 TMP 60E-2 \ 24"CHRY I 1 18"MPL ��'� 18POP GEORGETOWN GREEN \ ++ 8"MP I + MIN. 15.22'------i--- \ \ \ \ \ 1 ZONED: R-6 V 10"�CH 1 1 I BUILDING CORNER- \ USE: RESIDENTIAL \ \ I T SETBACK \ \ \ \\ \ 1 COMMON AREA / 12"P P \ II \ I ZMA2006-14 i �� ?���� �I 1 1 \ \\ ® -------------�--\ 0 P10 I Wr1BMP j 0' _. ,I' \ \\. xm \I �\\\ \ \ 1 \ \\`--------- / \ \ \ \ \ EX. CHAINLINK FENCE ✓ 0" Oq 4 I o f EXISTING TREES IN BOLD - - - _ - - - \ \ \ \ \ \ TO BE REMOVED (TYP) \\ \ I? T� is <°�\ \ 1 I \\-' -\ 6"PO 0' llOP Mri. _ , i + BOX 1 \ 1 / / / / / / / / / / / i / I 1 8"OAK ml oO" I is• n. v 1 v v ® \ - . ' I ° BENCHMARK BPOP ( 11d'DtJF' 20"POP 3A I 1 TRAFFIC BOX \ \ ---�_ A _ 8"OPIN 8"SiC �n,i I ELEVATION=614.7? - �- I A �4 i � i< �:: � �- �h y °a l 1 i f— j� �5. / J" s`2 r' MIN. 21.85' BUILDING CORNER 20"POP I + I ��Mg2e�<p 2"PO I + �' s `' SETBACK ZMA2006-14 1 V A'; '• '1i 1 �06,/<A0 21 + L , �'� I + 12"LOC I 1 65C A \ \ / I N1 a, (q (DEAD) / II i� 1 �1 EX. 15' RWSA EASEMENT 1 ® \ 1 - + i 12')~Po � ,: w(soILTYPE) 1 \ 12 "POP DB 466 PG 246 8"POP . " / I I ti� , a MIN. 13.4T "LOC BUILDING CORNER 24 MAP s V ® \ R PV + �•- ) SETBACK �8.5 la ` I EX. V W VEPCO EASEMENT 1 �I p I / 1 '�\ ZMA2006-14�............... + I DB 466 PG 246rSIGN \I t�n. ............::.............. ::>'".:::;':?':;`?:"""???a'':.;::. 12" 0 � , STOPLIGH POLE ..............................................:.... . 24"OAKX4 I z / � ♦ - :`:;::i.:'::::::r.;:�_.::.8°POP '�"Pop "POP r„T5,� ii:i:i:i: e.;'/!j / \ 1 \ / 1�"PINE FL''::::::...' ::::::::::::::::::::::::::::::. / \*�a✓' � � iO / @i ♦ I\I ,.;.:.%"."::::........:.`..`............:.....:1 /36" OAKX2 .:..............:..'::.:.:.::... 8"POP 15p) BEGIN CURB &/SIDEWALK DEMO 10 6"CHRY \ /i _ / 411 DEAD � ter' ( ) y / F / ' aP 1/......;'!4.............:::gix!"5iiiiiiiiii::.. �1L M, L " o� EX. 12 ACSA EASEMENT' :::::::.:::::.................. 1 "OAK / / DB 440 P 90 Cs' .'., }Q::tvi33 :::::i:::::::::.`:::..........::':.:::: + / / + / ® / ,:�;:.,,;,.,;:::::.. ,,,^!;iF� 12"CHRY / \ �/����� Jam / / ♦ 1 I �}"'ay 20;P + I I TMP 60-76B ♦ � 1, °..'°,'/�,,V � ��` / / / 0 // //� / MICHAEL & MELINDA �+ \ 11 I \, k'`';: :'>i>` ��l ��,? jV �� �o ® 27B I� I I \ w-,/ 7 /! / �h� ® (SOILTYPE) ZONED: RA USE: �ESIDENTI L ♦ I I +, // / �j ® ,/� 1 1 I _, NOTE: I I �-♦♦♦♦ I ® I F EXISTING ACSA WATERLINE. THIS IS / ♦ I ® I / ® / I \ A CRITICAL WATERMAN AND CARE I I PROPOSE / ♦♦♦♦ SHOULD BE TAKEN NOT TO DISTURB ♦ 1 I WATER / ♦♦ THE LINE DURING CONSTRUCTION. a. / I EXISTING 12' ACSA EASEMENT TO /7"60 EX. 12' ACSA EASEMENT - - - ` ® ) J �/ % ® BE VACATED. NEW 20' ACSA _ _ _ DB 440 PG 90 TO BE VACATED / EASEMENT TO BE CENTERED OVER / > PIPE. _ /// % zU g �I m w '• to 0 U -° Z z r O of Y; 2 QM <J 0 UBE U a� m aL w 0co 6-o D _j � a J Z v Q( 0 Z Ir - > o �j CO o M+1 lL Z BE0 Z BE a v BE N v t1 N w Q U7 z > 0 U J a J = 0 f ) O w aC)0 W w �a m= rn 0 z a z y u O� 00 z z 00 w � v n 0 0 zN PyTH Op Dt��,-� Jimmy L. Taggart Lic. NO. 22841 w4 4'oT 07/31/2020 tyG ��SlONAL E U_ J � a Q a - z z Cyy) O Hi Z _j CD E� - a Q wU > o J Er W tl = < _ A wzLL� 41 m Mz Cfl � z J 0 14. o Z ~ z ,�� �z o tr O � 0 z H W "' 0 x w DATE: 10-25-2019 SCALE: 1 ":20' JOB: 19.0125 SDP-2019-00062 SHEET: 2 OF 13 TYPICAL RETAINING WALL CROSS SECTIONS OF THE DIFFERENT TYPE OF WALLS USED ON THIS PROJECT NOT TO SCALE SEE RETAINING WALL DESIGN PLANS, BY OTHERS, UNDER SEPARATE COVER FOR ADDITIONAL DETAILS 42" Tall 5afety Handrail or Fence Post w/ Sleeve -It Fence -Post Anchor' 5 stem Max. 8'-0" O.C. Post Spacing Opt'oFnl (Handrail/Fence Installotion By Others) Top Dia. 7.4" Grout Fill After Post Installation w/ Min 3,000 psi Grout r Bottom Dia. 9.4" Non -Woven Filter Fabric - 4 FT Wide Mirofi 14ON or Equivalent r cantilever Bose 30.6"L x 15.3"W 12" Soil Cover 23 4" - I - I - - - - - - - • Reinforced Fill SLEEVE -IT SD1 FENCE -POST ANCHORING DETAIL (Not to Scale) Optional � I II II I I 8' SIDEWALK PROPOSED ALONG THE LENGTH OF THE PROPOSED 80' TAPER LANE I I CONNECT TO EXISTING CURB I qy RETAINING WALL #1:REDI-ROCK 13.5' I MAXIMUM HEIGHT. SEE RETAINING WALL PLAN j UNDER SEPARATE COVER, BY OTHERS. SEE I NOTE 4 THIS SHEET. SEE RETAINING WALL DETAIL FOR VEHICLE & PEDESTRIAN BARRIER J ■ I DESCRIPTION. w - I 80' PR POSED RIGHT RN TAPE I � . EXISTING CURB w io: � CRITICAL SLOPE PER ALBEMARLE COUNTY GIS - SLOPES GREATER J WM a w I I I THEN 25% - APPROXIMATELY 5860 SF TO BE DISTURBED. NO TMP 60E-1 �� CD no ti DISTURBANCE TO BE DONE IN PRESERVATION AREA DYNAMIC INVESTMENT aN . a. `�' ��� ► CAPITAL ENTERPRISES "' �� I RETAINING WALL #2:ANCHOR DIAMOND PRO BLOCK ZONED: C-1 USE: OFFICE BUILDiNO �� f� SEE SHEET 2 DEMO PLAN FOR EXTENTS OF 13.5' MAXIMUM HEIGHT. SEE RETAINING WALL PLAN I f f f I SAW CUT &MILLING OF PAVEMENT. UNDER SEPARATE COVER, BY OTHERS. SEE NOTE 4 2' CLEAR OVERHANG .No f wo PROPOSED PAVEMENT WIDENING IN THIS SHEET. SEE RETAINING WALL DETAIL FOR VEHICLE & PEDESTRIAN BARRIER DESCRIPTION. �. W- PROVIDED FOR VEHICLE �.., f0. _ __ - f 1 9•2 ACCORDANCE WITH VDOT STANDARDS. II I I ► 1 TMP 60E-2 ORGETOWN GREEN ZONED: R-6 � JSE: RESIDENTIAL � COMMON AREA � EX. CHAINLINK FENEE�� il ciz //\\ .BI00RLL OIO� gROW"W r"w1 r"eNe v11 FmH�wmw®�"dam¢ / rvn'W�-"mm�"'nGe�m"xvwraum � � awr x. aw_u. wwnmumunw mminvs ¢wniowmemiinsuereunc u,Ev .v"n�m"nsurnunio.�u �Welw V� .� . T FNC NIFBFANDOMK CFCOFINa REDHROCK' .-XCfFFESTwNaING FlO<F COFING REDIWOCK' WIM MCF A"ACNMBa lMll llNCF IawCMMENI f�e¢p"+"e.stivannxas r rve4Wwy.r��"uw 9". n,.n NEW 20' ACSA EASEMENT a3 f MANHOLE TO BE LOWERED TO PROP. GRADE e �f I !ADD TRAFFIC RATED COVER 20S1_�� q 2 2' OFFSET FROM TRAVEL LANE 20 -__ SPOIS X ■ PAINT ► r� - r�td s I,p -`- r I I I ► .........................::::-'� �. -. --- CG-3 SCALE: 1 /f:,; -e :� I 7 d -I of / I ................... ?/ ,;;;;;iiiiiiiiiiiiiiiiiiiiiii. o . ! -1 ?- 1 O� R i .? RIGHT-IN/RIGHT-OUT ► BOUNDARY CURVE TABLE Curve Length Radius Delta Tangent Chord Chord Bearing C6 16.68' 235.00' 4'04'03" 8.35' 16.68' N 00'37'30" E C7 64.64' 265.00' 13'58'33" 32.48' 64.48' S 04'19'46" E C11 97.24' 1696.02' 317'06" 48.63' 97.23' S 12'57'35" E C13 22.01' 60.00' 21-01'16" 11.13' 21.89' S 04'2131" E C17 23.84' 60.00' 22-45'58" 12.08' 23.68' S 27'29'12" W LEGEND: GIS CRITICAL SLOPES >25% PRESERVATION AREA CONSERVATION AREA / �.�„'ia1:ia; u.'ll ENTRANCE MEDIAN 1 �, � � PROPOSED HANDRAIL ' i /i � * � ALONG LANDSCAPING � � �1��_,r gS• •; t ISLAND I I r 40, * i* DENOTES START OF VEHICLE 1 FH � 15 i I C) ► � BARRIER; MOD�IED GR-2 p I ► t WITHOUT BLO�KOUTS OR �� 1;'I 1 APPROVED EQUAL IN FRONT OF G) � 1 1 � PARKING SPATS, CLEAR OF 2' I I �� li 12" WIDE I -.I • . �„ I � II 1 I OVERHANG. ' ESIGNED BY 1�t 11 ,CURB CUT ^ 0`1ERNANG RETAINING WALL � I 1 i OTHERS. SE WALL PLANS #4: BY OTHERS. 1 UNDER SEPARATE COVER FLUSH MAX HEIGHT 4' oo Ih I► CURB I ,,,•, {j. � I I ► r PEDESTRIAN FALL1� HANDRAIL w1 � PROTECTION PROVIDED I .I I'TMP 60E-3 9 x16 i�A'• �s 9 Egg' MINIMUM 9.63' BUILD -TO CORNER SETBACK PER ZMA2006-14 I WHERE FALL TALLER THAN 1.05 ACf1?ES (TM) Lot; I ■ ,y 30". DEi;IGNED BY OTHERS. FDC CONNECT TO EXISTING CURB ► ' 01 I SEE WFjLL PLAN UNDER EGRESS { Np LO1 I SEPAR�TE COVER � { ktil i �� f16� 1 (TYP) I { (REMOVAB � I I'.' `�. • ;: � I � I � ', PAINTED 1 I I I I % 111'I II STRIPING UNDER ► I 12' CLEAR OVERHANG BUILDING { 11,• � 1 Flj, •� `L = I ► � 1 � I PROVIDED FOR BUMPER 1 I VEHICLES BLOCK I { 1 1 "• •'t 1 %' PROPOSED I i II BENCH TIP) � ' 6 I I 1 - PRESERVATI:;N --' V�_ AREABUIINGI 651� I COLUMNS FFE= ► � 1'i , �- I BFE-605.8 { 1 �'.�.-=>� W (TYP) I { I � 1 1 11 • '' '� '•?� ^� 1 1 I II D � �' 1 "I I{ � 11 II � z = { . \I �I :�.•�• t;,35 � Q I ► I 3.5' GRASS STRIP � 1 1 � Q� i c: �,1,11 1 N `�a - :'.. • -:• ADD 9' CONC. SIDEWALK BEHIND EXISTING ID- "�••.i, :::� SIDEWALK PER CODE OF DEVELOPMENT (2) PICNIC TABLESt I � I \ �Im + •� 1 1 >< tI BUILDING"ATRA C � ► I IF CE 1�iiL�' .Box i .. •:::� 1 , 0 20 40 BOUNDARY LINE TABLE Line Direction Length L1 S 14'44'06" E 14.39' L2 N 77'42'45" W 4.50' L3 S 15'21'39" W 10.20' L4 S 82'18'27" E 5.22' L5 S 38'50'59" W 79.63' L6 N 6412'41" W 166.59' L7 N 10'52'19" E 210.70' LS N 80'05'19" E 143.39' NOTES: 1. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 2. PROPOSED SITE ENTRANCE TO BE RIGHT -IN &RIGHT -OUT ONLY 3. RETAINING WALL DESIGN TO BE SUBMITTED UNDER SEPARATE COVER, BY OTHERS. WALL A -SECTION 1, AS SHOWN, IS ASSUMED TO BE 2 FT WIDE WITH NO BATTER AND NO GEOGRID. 4. ALL RETAINING WALLS OVER 30 INCHES TALL WILL HAVE PEDESTRIAN SAFTEY RAILS AND/OR VEHICLE STOPS WHERE APPLICABLE. 5. CONTRACTOR IS TO CONTACT ACSA 3 DAYS PRIOR TO TYING SEWER MANHOLE, TO SCHEDULE AN INSPECTOR ON SITE. 6. EXISTING ACSA WATERLINE IS A CRITICAL WATERMAN AND CARE SHOULD BE TAKEN NOT TO DISTURB THE LINE DURING CONSTRUCTION. EXISTING 12' ACSA EASEMENT TO BE VACATED. NEW 20' ACSA EASEMENT TO BE CENTERED OVER PIPE. 6. THE ENTIRE TRAVEL WAY ON THE PROPERTY IS DESIGNATED AS A FIRE LANE. 7. A KNOX BOX WILL BE PROVIDED -LOCATION TO BE APPROVED BY THE FIRE CODE OFFICIAL. 8. THE 6-INCH BUILDING COLUMNS IN THE PARKING AREA UNDER THE BUILDING ARE SHOWN. THEY WILL BE LOCATED BETWEEN THE PARKING BAYS. THEY ARE DEPICTED WITH A CIRCLE THAT IS NOT TO SCALE FOR ILLUSTRATIVE PURPOSES. PLEASE SEE ARCHITECTURAL DRAWINGS, SUBMITTED BY OTHERS, FOR MORE DETAIL. 9. CURB RADII ARE MEASURED AT FACE OF CURB; FLOWLINES ARE MEASURED AT THE GUTTER PAN. AREA SUMMARY PRESERVATION AREA 11,445 SF CONSERVATION AREA 6,310 SF AMENITY AREA 1,010 SF A m U �J m C0 U o U -° O Z z U) Ot Q�> o QO) g� J U T J = Qi 00 aU m O- Z = w Ow Wo D -1 MQ ° aZ vU ZO \¢_ M / N wO o Cn n CEi a v fL w Q z J > O F W d >- C0 > _ 0 lL O a C UUO W w M �a rn = rn U Z 0 a O� L) U z z 00 0 0 w � � v W 0 0 ZN PVTx OF/Df�c2 Jimmy L. Taggart Uc. No. 22841 0 08/ 3/2020 ESSIONAL F'�G J Q g z°C`J5 N Q � LU a _ Cr W I� W Q y. �zLLW o FD �oQ J z� <0 _ w x � a �o �o F U U) /0 0 DATE: 10-25-2019 SCALE: 1 ":20' JOB: 19.0125 SDP-2019-00062 SHEET: 3 OF13 Rivanna Water & Sewer Authority (RWSA) General Water & Sanitary Sewer Notes Last Revised: April 2016 1. All materials and methods of construction shall comply with the latest version ofthe General Water and Sewer Design and Construction Standards - Version 1.0, adopted in December 2015, except as modified below or modified in special notes. 2. RWSA shall approve all construction materials and methods of construction. A preconstruction conference shall be held with RWSA prior to the start of any work. 3. The contractor shall be responsible for notifying Miss Utility (1-800-552-7001). 4. RWSA Engineer (Victoria Fort at (434) 977-2970 ext. 205) shall be notified three business days prior to the start of construction. 5. All work is subject to inspection by RWSA staff. No tie-ins to the existing system shall be made without coordination with and the presence of RWSA staff. No work shall be conducted on RWSA facilities on weekends or holidays without special written permission from RWSA. 6. For sanitary sewer line construction: RWSA may require bypass pumping for tie-ins to the existing system. All doghouse manholes must be pressure -tested before a connection is made to the system. 7. The location of existingutilities as shown on the plans is from data available at the time of design P and is not necessarily complete lete or accurate. The Contractor shall be responsible for the P verification of the location, size and depth of all existing utilities, both surface and subsurface. The Contractor shall immediate) notify the Engineer of an discre ancies between the plans and Y fY 8 Y P field conditions. The Contractor shall use due diligence to protect all utilities and structures from damage at all times, whether shown on the plans or not Damage to any existing utilities shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 8. Erosion and sediment control facilities shall not be permitted in the RWSA easement without special written permission from RWSA. No grading shall be permitted in the RWSA easement unless Permitted otherwise by RWSA in writing. 9. No blasting shall be permitted within 100 feet of RWSA facilities without written permission and RWSA approval of the blasting plan. Ground monitoring during blasting and a pre -blast survey may be required. For blasting within 100 feet of any operative RWSA sewerlines, bypass pumping and/or pre- and post -CCTV may be required. RWSA may also require certification from a licensed professional engineer stating that the proposed blasting will not damage any RWSA facilities. Damage to any utilities due to blasting shall be repaired by the Contractor to the original condition at no additional cost to the Owner. 10. The contractor shall observe minimum separation requirements for utility crossings. When a crossing is made under an existing facility, adequate structural support shall be provided for the existing pipe. The area of the crossing shall be backfilled with compacted 57 stone to the springline of the existing pipe. 11. New water main installations shall be pressure tested, chlorinated, flushed and have water samples approved prior to making any permanent connection to the public water system. Approved methods of filling and flushing new water mains will be required to prevent any contamination of the public water system. 12. All easements for new RWSA facilities shall be recorded prior to placing the new facilities into service. 13. No permanent structural facilities will be permitted in the RWSA easement. This includes building overhangs, retaining walls, footers for any structure, drainage structures, etc. 14. Trees are not permitted in the RWSA easement. TYPICAL SECTION OF UNDERGROUND DETENTION SYSTEM NOT TO SCALE. SEE VSMP FOR MORE DETAILS 1.5" SM 9.5A 1.5" BM 25.0 6" VDOT 21A 15" WELL COMPACTED CLEAN FILL GEOSYNTHETIC NON -WOVEN GEOTEXTILE -12" CLEAN WASHED #57 STONE - 42" ADS MC-3500 STORMTECH CHAMBERS (OR APPROVED SIMILAR). PLACED FLAT ON STONE BEDDING (0% SLOPE) -12" CLEAN WASHED #57 STONE BEDDING -WELL COMPACTED CLEAN FILL PER GEOTECHNICAL ENGINEER'S SPECIFICATION Project Hydraulic Office Building Occupancy B Business Occupants 100 gross WC -male 1 per 25 for first 50; 1 per 50 for remainder WC -female same Lavatones-male I pef 40 for first 90;1 per 80 for remainder Lavatories -female same Tubs/Showers n/a DF I per 1010 Service Sink 1 per building CRITICAL SLOPE PER ALBEMARLE COUNTY GIS - SLOPES GREATER THEN 25% - APPROXIMATELY 5860 SF TO BE DISTURBED. NO DISTURBANCE TO BE DONE IN PRESERVATION AREA RETAINING WALL 13.5' MAX. SEE NOTE 3 & 4 THIS SHEET II I I I II I � I I e.•. I I 80' PR POSED BOUNDARY CURVE TABLE Curve Length Radius Delta Tangent Chord Chord Bearing C6 16.68' 235.00' 4'04'03" 8.35' 16.68' N 00'3T30" E C7 64.64' 265.00' 13'58'33" 32.48' 64.48' S 0419'46" E C11 97.24' 1696.02' 3*17'06" 48.63' 97.23' S 12'57'35" E C13 22.01' 60.00' 1 21'01'16" 1 11.13' 1 21.89' 1 S 04121'31" E C17 1 23.84' 1 60.00' 1 22-45'58" 1 12.08' 1 23.68' 1 S 27-29'12" W RIGHT RN TAPE I LEGEND: t I t I I � GIS CRITICAL SLOPES >25% 0000 sows 1000 Novo 1 MANHOLE TO BE LOWERED TO PROPOSED PRESERVATION AREA t� GRADE. ADJUSTED TO FINISHED ASPHALT SURFACE. 1 I � CONSERVATION AREA ' 1 1 1 SEE SHEET 2 DEMO PLAN FOR EXTENTS OF n� ' /5 L8__ I I s SAW CUT & MILLING OF PAVEMENT. SF-��'NMN f f ��.-♦�: '..1. I �- PROPOSED PAVEMENT WIDENING IN 59� 5a f .�������� _ ACCORDANCE WITH VDOT STANDARDS. p 589 68 - - - _ - - _ - •� t 1 1 V �I 1 I I I RETAINING WALL #1: REDI-ROCK 13.5' MAXIMUM HEIGHT. SEE RETAINING WALL PLAN UNDER SEPARATE COVER, BY OTHERS. SEE NOTE 4 THIS SHEET. SEE RETAINING WALL DETAIL FOR VEHICLE & PEDESTRIAN BARRIER DESCRIPTION. 1 � II TMP 60E-1 DYNAMIC INVESTMEN CAPITAL ENTERPRIS _ ZONED: C-1 USE: OFFICE BUIL )INC. I logo f� S/ 000000 f 0000 a Z N w� � In ¢ o W � Co J � W ¢ �L t- ut¢ W j WM N in to Z w0 00 so BOUNDARY LINE TABLE Line Direction Length Li S 14'44 06 E 14 ' .39 L2 N 77'42'45" W 4.50' L3 S 15'21'39" W 10.20' L4 S 8218'27" E 5.22' L5 S 38'50'59" W 79.63' L6 N 6412'41" W 166.59' L7 N 10'52'19" E 1210.70' L8 N 80'05'19" E 143.39' /So s s sp BW599.o� - ____---- _I I 1 1 20 0 20 40 60 1 } ° -14 - - _ -I - 3 GATE VALVES, TEE CONNECTION AS SHOWN --__- I I a n I 1 SCALE: 1"=20' ,# s _ _ _ I I . 12" x 6" TS&V I ' CO - 20' WIDE ACCESS .'.. ff'W/ REDUCER a NOTES: c_)•o EASEMENT STATION 10+87.75 PROPOSED SANITARY LATERAL CONNECTION. CONTRACTOR , �' 1 " W Ss .G _ PROPOSED FHA SEE SHEET 5 _1_ 1 1. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE � � I IS TO CONTACT ACSA 3 DAYS PRIOR TO TYING INTO I �I f I CORRIDOR SHALL BE ELIMINATED. MANHOLE TO SCHEDULE AN INSPECTION ONSITE & 20' EASEMENT 11 2. PROPOSED SITE ENTRANCE L FH 1 1 1 1 1 II 3. RETAINING WALL DESIGN TOTBEB_SUBMITTEDNSEPARATERIGHT-OUT UNDER SEPARATEENLY COVER, BY RETAINING WALL GANCHOR DIAMOND PRO BLOCK 1 1 1� I I END OF ACSA 1 1; I OTHERS. \ 13.5' MAXIMUM HEIGHT. SEE RETAINING WALL PLAN p 1 ■ I I ` I PUBLIC WATER \ UNDER SEPARATE COVER, BY OTHERS. SEE NOTE 4 I O1II SYSTEM I 1 4. ALL RETAINING WALLS OVER 30 INCHES TALL WILL HAVE PEDESTRIAN \ THIS SHEET. SEE RETAINING WALL DETAIL FOR VEHICLE I Jr �4t 1 - _ _I ` 1 SAFTEY RAILS AND/OR VEHICLE STOPS WHERE APPLICABLE. \ & PEDESTRIAN BARRIER DESCRIPTION. 111 I -HUGE ° I I 11 5. CONTRACTOR IS TO CONTACT ACSA 3 DAYS PRIOR TO TYING SEWER \ \ 1 1 ) 1 1 1 TO SCHEDULE AN INSPECTOR ON SITE. I 11 I . \I � ► MANHOLE, I RETAININGsWALL #4 11 6. EXISTING ACSA WATERLINE IS A CRITICAL WATERMAIN AND CARE SHOULD \\ \\ 1 I 24"PINE -i f EXPECTED �LEC. 1..'..} \ rl I + �, 1 1 BE TAKEN NOT TO DISTURB THE LINE DURING CONSTRUCTION. EXISTING PRIMARY RgUTE \ { `l,rj. 1 1 I 12' ACSA EASEMENT TO BE VACATED. NEW 20' ACSA EASEMENT TO BE ,� LIGHT P01 T & CENTERED OVER PIPE. v 1 I + I 1; OVERHAN (TYP.) o I )1 + 6. THE ENTIRE TRAVEL WAY ON THE PROPERTY IS DESIGNATED AS A FIRE 1i 1 I I LANE. 10 "POP PIN I 1l LIGHTS (TYP) FDC F:.", :\ ...-� I 7. A KNOX BOX WILL BE PROVIDED - LOCATION TO BE APPROVED BY THE JI TMP 60E-3 J. I I I ..., 1 I 1.0q ACRES i t! 1 1 I I h' FIRE CODE OFFICIAL. 12"OAK _ / i I I 1 x ° 8. THE 6-INCH BUILDING COLUMNS IN THE PARKING AREA UNDER THE 1 ' ROOF DRAINS DISCHARGE TOWARDS BACK 11 TRAFFIC BEARING \ 6 I 1 I 1 'r..\. ;.11 1 1 1 BUILDING ARE SHOWN. THEY WILL BE LOCATED BETWEEN THE PARKING 1 8 ++L OF BUILDING & TIE INTO UNDERGROUND j ;j I I SANITARY CLEANOUT I 1 1 1 11 BAYS. THEY ARE DEPICTED WITH A CIRCLE THAT IS NOT TO SCALE FOR 1 STORAGE & WILL NOT CROSS VDOT ROW. n�_�_ N MIN INV ELEV: 591.6 FOR �\ PLEASE SEE ARCHITECTURAL DRAWINGS I �� I 2.08% TO EX. MANHOLE I \ 1 s 1 1 ILLUSTRATIVE PURPOSES. PLEASE SEE ARCHITECTURAL DRAWINGS, HVt bt1,,.6� S 1 s �# Pv� SAyt LAT I I SED SUBMITTED BY OTHERS, FOR MORE DETAIL. 5 i FOR MORE DETAILS I I I'. a:: •'•. W f1 1 1 124"PINE J l C.G >ti --- - :; = - 6' SDR3� I pROPO Y 1 1 PRESERVAT - -g_$TOR I \ 1\ G 1 1 I G 1 1 , ... •�,... 1 110"POP I AREA yr1 - BUILDIN 615.a I 1 I 1t .:� ►1 T 1 I I � r, ---- 1 I FFE= \ I , , .i..� ^•. �I L7j � 1 1 I 15"CHRY i ( I 1 I sFE=6D5.a 1 1 1b j 20"MP � � ,, 1 I 1 1 1 1\ 11 O 1 1 UNDERGROUND DETENTION 1 SYSTEM TO BE ADDRESSED I I I 10°CHRY I f �. I, j I I 1 1 I I ON VSMP SUBMITTED UNDER I 1 1 %� ;:::�1 70 Q 1 _ I 1 I SEPARATE COVER GEORGETOWN GREEN ' 8'MPL + ` 4 PROP. SWM EASEMENT TMP 60E-2 \ 24'CHRY I+ 8"MPL I 1 r ZONED: R-6 1O"BCH I 1 1 1 I :�. 1 1j ' 1', ::. NEW 20' RWSA EASEMENT 1 1 USE: RESIDENTIAL > 1 l I i ,\ COMMON AREA / I p__i. LIGHTS 1(TYP.) 11 1 I I I 1 1 �• 1\ 1 1 1 12"P P I'. / 0 OP I8"MPL I I I1 I 1 1 I I 1 A 1 1 ' \'•�''`1\ 1 0" 0P j + o M� I 1 DI-361 1 1 I I \. EX. CHAINLINK FENEE� I 1 I I I I `1 L-_ 8' \ 1 r1RA Fief 1 \-- -- 6"Pol 10"POP I 1 ) TOP: 1303.80 111 1 1 I I \ 1 I BOX �1 1 BENCHMARK 1 ' \ 8�POp I I I I \ TRAFFIC BOX I \'% // ) 1 1 11 II I i. I '• .\,y ''\\ELEVATION=614.79 1 III i+ I\ 1 / / 1 J I I I 1 10' PARKING SETBACK 1 N') 1 LIGHTS (TYP.) 1= 12"POP j ! ;% // / / ! I I >1j 1 1 NEW 20' A \' ! cC��, i / / / I^ LZ 1 EASEMENT \ 42"OAH I % / / / l / I y' 21.85 MINIMUM BUILDING CORNER SETBACK (ZMA 2006-14) - - I ' RIPRAP f I 1 " i 5x5 BOX .. I 7 / ' //` TOP:602.®0 ; // / / 12" ASSUMED / \ I I L4 sGN ^\< EX. VEPCO EASEMENT DB 723 PG 362 INSIDE FOOTER / ! I I \ HP®5� 2 / / / l 1 • ::. STOPLIGGH POLE 1 Code -Required Fixtures Discretionary Fixtures Tadets Lays Showers DF Bldg SerySink ollets Lan Showers Suite SerySink Other Sink SF Tenant Occupants M F M F M F ZA 1733 endodontist 18 9 9 1 1 1 1 0 0 1 1 0 1 6 ZB 1598 dentist 16 8 8 7 t U 0 1 1 0 1 2 2C 1691 prosthodontist I7 9 4 i 1 1 0 0 0 0 0 2 3A 1733 PT 18 9 9 1 I 1 0 0 0 0 0 2 36 1647 dentist 1J 9 9 1 1 1 0 0 U 0 ? 3C 1462 other 1= 8 8 1 1 0 i 0 0 1 0 connnnon n/a 1 Subtotals 103 6 6. 6 0 ? i 2 2 0 6 15 Total Estimated Fixtures s2 NOTE: a EXISTING ACSA WATERLINE. THIS IS / A CRITICAL WATERMAIN AND CARE SHOULD BE TAKEN NOT TO DISTURB THE LINE DURING CONSTRUCTION. EXISTING 12' ACSA EASEMENT TO BE VACATED. NEW 20' ACSA RETAINING WALL #3: 6' MAX. SEE EASEMENT TO BE CENTERED OVER NOTE 3 & 4 THIS SHEET - PIPE. PROP. 1.5" DO Tic j CONNECTION f I UP 1.5" ME BOX 000000 W� REDUC R ffffffff _ f / STATION 10+18.70 SEE SHEET 5 **NOTE TO CONTRACTOR: CONTRACTOR TO USE DISCRETION AND CARE WHEN CONNECTING TO ACSA MAIN. THE PROFILES OF EXISTING WATERMAINS SHOW ON PAGE 5 ARE SHOWN AT AN ASSUMED DEPTH BASED ON EXISTING GRADE. A r U o � ro W CO CO U Z ZaN O 0(0 Y> 2 J rn H 01 Q J U � J = �t 00 ¢J in w Din ¢o D �T•� 0 Q N Q fr Qyt J Z0 C7 W > o ti.j W o F+i wLL (7 n cn 0 Z rn N F--1 > o a W N N W Q z J > O aw li = U U J a J = CO � O aZw O _1 wfr MQ M m U z a N O� z Z 0 0 Z Z 0 0 w a 0 0 Z N T,T II aF Dr�� n 2• Jimmy L. Taggart Uc. No. 22841 -Po.„ 08/03/2020 4' �*SrONAL �lyG J Q Q z J Q W U _ W = a a a �zILL� �+ (n��pa Ey J Q O Q O w X Z V D ir 0 O ! V DATE: 10-25-2019 SCALE: 1 ":20' JOB: 19.0125 SDP-2019-00062 SHEET: 4 OF 13 PROFILE ALONG EX. RWSA 12" WATERLINE 625 620 615 610 605 ROP. GRADE EX. GRADE 3' MIN. COVER EX. J X U W J N Q W HO Izontcl Scale = 1 :20 d r Ve tical Scale = 1 :5 0 X w a o_ X w 10+00 10+20 10+40 10+60 620 615 610 605 595 590 585 580 575 570 565 10+80 11+00 11+20 11+40 11+60 11+80 12+00 12+20 12+40 12+60 12+80 13+00 13+20 PROFILE ALONG EX. ACSA 8" WATERLINE 13+40 X. GRADE 8s 3' MIN. COVER J a w 3 z Horizontal tale = 1 :20 Lu 0 Vertical Sc le = 1 :5 w = w a 0 0 w a 620 615 610 605 595 590 585 580 575 570 565 10+00 10+20 10+40 10+60 10+80 11+00 11+20 11+40 11+60 11+80 12+00 12+20 12+40 12+60 12+80 625 620 615 610 605 13+60 13+80 14+00 14+20 NOTE: 1. GRADE SHOWN FOR EXISTING WATERLINE ARE UNVERIFIED AND APPROXIMATE 2. THE EXISTING ACSA WATERLINE ALONG THE SOUTHERN PROPERTY LINE IS A CRITICAL WATERMAIN AND CARE SHOULD BE TAKEN NOT TO DISTURB THE LINE DURING CONSTRUCTION. EXISTING 12' ACSA EASEMENT TO BE VACATED. NEW 20ACSA EASEMENT TO BE CENTERED OVER PIPE. VARIES VALVE BOX TO METER BOX (SEE FIG. W-6A THRU W-7E). VARIES —2" COPPER WATER MAIN M.J. FITTING 4" DIP 4" PLUG THREADED FOR 2" COMPRESSION FITTING RESTRAINED JOINT FITTINGS NOTES: • GATE VALVE WILL BE 4" UNLESS OTHERWISE SPECIFIED BY THE ACSA. • SERVICE LINE TO CONNECT AT MAIN WITH X"xV TEE. • REFER TO FIG. W-3 FOR THRUST BLOCK DETAILS ON TEE. • REFERTO FIG. W-5 FOR THRUST BLOCK DETAILS AND DEPTH OF COVER ON GATE VALVE. • NO CONCRETE SHOULD BE POURED ON ANY PART OF THE RESTRAINED JOINT. USE PLASTIC SHEETING AS PROTECTION FOR BOLTS. • USE 2500 P.S.I. CONCRETE.. LARGE METER SERVICE LINE NTS FIG. W-6C TD-12 L METER SIZE DIMENSION DIMENSION DIMENSION A B C 1 1/2' 3'1' 5'0' 3'8' 2' 3'1' 510. 3'8' 3' 5' MIN. 4' 5' MIN. 12' MIN. TGREATER4 HAN ' PROPOSALS WILL BE SUBMITTED. B DOOR HINGES I I ( I I I I I I I I I I I I I LIFT HANDLE L— — — — — — — — — — — — — — — — TYPICAL METER VAULT N.T.S. FIG. W-7A TD-14 SIDE VIEW .75' ➢IAMETER DRILLED IDLE FOR TOUCH READ INITS, TOP VIEW 3" DIAMETER FLAT BEARING SURFACE UNDERNEATH ?4' 4LUMINUX36'M ACCESS 1ATCH "NOTE TO CONTRACTOR: CONTRACTOR TO USE DISCRETION AND CARE WHEN CONNECTING TO ACSA MAIN. THE PROFILES OF EXISTING WATERMAIN HEREON ARE SHOWN AT AN ASSUMED DEPTH BASED ON EXISTING GRADE. U w •. � N • VI O U OzU) O(0 zY> � GO Q 0 §< J 0 Co O U a ° m az =W pin wo D UQ �T � Q Z v U Z� V LD> o • In N W c� LLZ N O 0_ W N v N W Q Z J > O /1 Uw> a } 7 i _ Cl) O o z �/ 0 0 04 w Q rn = rn U Z O a 010 00 z z 22 2 2E 00 2 zz 00 u u 0 0 w Q N M � v � 0 0 Z '4 N �11TIl OF 41� �1�p do c r Jimmy L. Taggart Uc. No. ¢ 22841 '�0,,, 07/31/2020 �ssron�ai. U_ J Z a Q Q Z J CW W = 0- Q a �zLL2E M4 ��� j a z 0114 :E E w z w 0 D E� Ir ~ S 0 U DATE: 10-25-2019 SCALE: 1 ":20' JOB: 19.0125 SDP-2019-00062 SHEET: 5 OF13 CONTRACTOR RESPONSIBILITIES REGARDING ADA COMPLIANCE: CONTRACTORS SHALL PERFORM WITH REQUIRED CARE AND PRECISION IN CONSTRUCTION OF ADA (ACCESSIBLE) COMPONENTS AND \ \\ \ I I It It I I it I I I 1 ACCESSIBLE ROUTES WITHIN THE SITE. THESE CONSTRUCTED PRODUCTS, AS THE CONTRACTOR LEAVES THEM, MUST COMPLY WITH ALL l \ \ \ � � � I I 1 APPLICABLE STATE AND LOCAL ACCESSIBILITY LAWS AND REGULATIONS AND THE CURRENT ADA AND/OR STATE ARCHITECTURAL \ \\ \\ \ I I \ I I I �/ - CONNECT TO EXISTING CURB I 1 ACCESS BOARD STANDARDS AND REGULATIONS' BARRIER FREE ACCESS AND ANY MODIFICATIONS, INCLUDING REVISIONS OR UPDATES. \ \ \ I \ \ I FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE(S) FROM PARKING SPACES, PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, \ \\ \\ I \\ It INTER -BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCE OR EXIT, MUST COMPLY WITH THESE ADA OR ACCESS BOARD \\ \ \ I \ l \ \ \ CODE REQUIREMENTS. THESE INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: \ \ \ I I / \ \\ Lo ICI I 1. HANDICAP PARKING SPACES AND PARKING AISLES - SLOPE SHALL NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) IN \ \ \ \ I I \ z� ANY DIRECTION. \\ \\ \ I It 2. RAMPS (CONCRETE OR OTHERWISE) - SLOPE MUST NOT EXCEED 1:12 (8.3%) FOR A MAXIMUM OF SIX (6) FEET. \ \ \ V 1 / I N ° 3. LANDINGS - MUST BE PROVIDED AT EACH END OF RAMPS, MUST PROVIDE POSITIVE DRAINAGE, AND MUST NOT BOUNDARY CURVE TABLE Curve Length Radius Delta Tangent Chord Chord Bearing C6 16.68' 235.00' 4'04'03" 8.35' 16.68' N 00'37'30" E C7 64.64' 265.00' 13'58'33" 32.48' 64.48' S 0419'46" E C11 97.24' 1696.02' 3'17'06" 48.63' 97.23' S 12'57'35" E C13 22.01' 60.00' 21'01'16" 11.13' 21.89' S 04'21'31" E C17 1 23.84' 1 60.00' 1 22-45'58" 1 12.08' 23.68' S 27-29'12" W EXCEED 1:50 (1/4' PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. \ \ \ 1 I\ II I I '- co 80' PR POSED 4. ACCESSIBLE ROUTE PATH OF TRAVEL - MUST PROVIDE A 36-INCH OR GREATER UNOBSTRUCTED WIDTH OF TRAVEL \ \ \ \ 1 \\ II I 1 r I RIGHT RN TAPE I LEGEND: (ENCROACHMENTS SUCH AS CAR OVERHANGS OR HANDRAILS CANNOT REDUCE THIS MINIMUM WIDTH). THE SLOPE MUST BE NO 1 \ \ \ I \ II I I / <wo wv GREATER THAN 1:20 (5.0%) FOLLOWING THE DIRECTION OF TRAVEL, AND MUST NOT EXCEED 1:50 (1/4" PER FOOT OR \ \� \ I \ II N wQ NOMINALLY 2.08%) FOR CROSS SLOPE. WHERE PATH OF TRAVEL WILL BE GREATER THAN 1: 20 (5.0%), \�1 I 1 W wc� ws I I I ❑ 00 GIS CRITICAL SLOPES >25% RAMP SPECIFICATIONS I CRITICAL SLOPE PER LBEMARLE COUNTY GIS -SLOPES GREATER ( TMP 60E-1 ¢ I (ABOVE) MUST BE ADHERED TO. MAXIMUM SLOPE OF 1:12 (8.3%), FOR A MAXIMUM RISE OF 2.5 FEET, MUST BE PROVIDED. RAMPS THEN 25% - APPROXIMATELY 5860 SF TO BE DISTURBED.�IQ DYNAMIC I60E- l EN CD, Woo wo ti MUST HAVE ADA HAND RAILS AND "LEVEL" LANDINGS ON EACH END THAT ARE CROSS SLOPED NO MORE THAN 1:50 IN ANY DISTURBANCE TO BE DONE IN PRESERVATION AREA \ \ CAPITAL ENTERPRIS ; 3�m NO 1 DIRECTION (1/4- PER FOOT OR NOMINALLY 2.08% FOR POSITIVE DRAINAGE. \ \ RETAINING WALL #1 jjjCO PRESERVATION AREA (/ ) ZONED: C-1 z w - 1 5. DOORWAYS ALONG ACCESSIBLE ROUTES -MUST HAVE A "LEVEL" LANDING AREA ON THE EXTERIOR SIDE OF THE DOOR THAT IS \ �� USE: OFFICE BUIL )ING �00 { 1 Y I SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (1/4" PER FOOT OR NOMINALLY 2.08% FOR POSITIVE DRAINAGE. THIS \\ FLOW LINE (/ ) � RI�TAINING WALL 13.5' MAX. SEE NOTE � & 4 THIS � � , I I 1 LANDING AREA MUST BE NO LESS THAN 60 INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE PERMITTED BY ADA STANDARDS SHOT _ - - 0000 I I I 1 FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICCANSI A117.1-2003 AND OTHER REFERENCED INCORPORATED BY CODE.) ,..� �� / I ► CONSERVATION AREA 6. IF PROJECT INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ADA COMPONENTS FROM EXISTING f��� _ -_ _ / 1 SEE INSET BOTTOM 1 1 DOORWAYS OR SURFACES, CONTRACTOR MUST VERIFY EXISTING ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF p3 ,, s �� / / ;,' OF SHEET FOR SLOPE 1 THE DEPARTMENT OF JUSTICE'S ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE 5 s��go CIRCUMSTANCES. THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES ANDOR FIELD 0 a0' e 5 COMMENCONDITIONS THAT CEMENT OFDIFFER THAT INANY WAY OR ANY RESPECT MPROVEMENTSPLACEDFBOMTHEHAT IS CONTRACTWN ON TOR MUSTHFAPL WITHIN THRITING, BEFOREMAXIMUM AND MINIMUM \ \ \ o� tS FP�yNM9 �' II BOUNDARY LINE TABLE Line Direction Length L1 S 14'44'06" E 14.39' L2 N 77'42'45" W 4.50' L3 S 15'21'39" W 10.20' L4 S 82*18'27" E 5.22' L5 S 38'50'59" W 79.63' L6 N 6492'41" W 166.59' L7 N 10'52'19" E 210.70' L8 N 80*05'19" E 143.39' LIMITATIONS IMPOSED BY THE BARRIER FREE REGULATIONS AND THE ADA REQUIREMENTS. \ 20 Sa 6ssMH Tw sos. - - i _ _--90 1 5�� /.'t :::::::. BW 599. x - - i 1 CONTRACTOR TO I 7. CONTRACTOR SHALL VERIFY THE SLOPES OF CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCE IS \ S��♦ �, �q / / !_-- I I ENSURE POSITIVE 1 20 0 20 40 60 ,- OBSERVED OR EXISTS, CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER PRIOR TO POURING CONCRETE. CONTRACTOR IS \� s ♦., DRAINAGE AROUND 1 RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND REPLACE NON -CONFORMING CONCRETE. ♦♦ / I A i i _ _ - b I 6 I ENTRANCE MEDIAN I 1 SCALE: 1"=20' 1 A _ CONTRACTOR IS URGED TO REVIEW THE INTENDED CONSTRUCTION WITH THE LOCAL BUILDING CODE AFTER FORMS ARE SET AND PRIOR \ ♦ - ' i+ I \ // 1 I f I TO COMMENCEMENT OF CONSTRUCTION OR IMPROVEMENTS. _ ♦ __--- ��lr_.o I 1 \`--- \\ ♦ I /+�" I I �\ i w`ea0, `✓�l' � � g�% CG-12 � 11 .:•:. r, I 1 ♦ L ;r Z_ �_ Z - - - I 11 ♦ RET,pININt WALL #2 ♦ +�+ I 1 1 \ 1 i "fs' I I'1, i ti 6gg� I I 11• 1 A + 10 FH I I 1 I i* I \t \\ t 1 :i 'il / r i 7°I i � � e b I. I I y I► I �C _ NOTE: ^� 5.0% 7 • �' - - CONTRACTOR TO USE PARTICULAR CARE TO AVOID DISTURBANCE OF 1- ---- PRESERVATION AREA J X - I \ \ ,I 1t r;,�o70 'I / ��p'I•I �N � ,,.:p: 1f 1 ', 7 i / - - _ _ _ _ / --j•� \ I I 1 IC;r-�,:Y BfiQO �, / 1% I ' ` •� :.' ti. :? I I II 1 / - \ ` \a y I 1 I I I \ ( i I L iIA'I,`---7--- 06X V 1 1/ 1 �I I I 1 / / I ,O.p�kl� �1 I \ li '' ►'/ 111 II OS( _--- •/� s9 + \ 1 I I l� I It czotit 0 1 �O�`, liti I1� XI ❑ F I I TMP (\OF-3 1 i i• I II 11 I I '' CONNECT TO I - " \ 1 1 \ 1.0q1 TES I 1 a�1 ' !i ! / I I 1 20' ACCESS I \' 2s k ':;1 \ EXISTING CURB I it I I EASEMENT CURB 1 O ¢ e 1 I I \ I I i i, \1 I 11... GUT 1 \ �• 1 I \ I I I '/ h" :,1 Y I I 1 1 " - cs � � O •9 a` 1 I v I 1 ) r� �,•,d e _; _, I I I 11 I '. 1� ;� �. Q 1 v lCD I - 1 ORY 11 1 ;' : >A1 N G \ . v 1 PRES�jiVAT ?4 _ _ - -i - - -1 I I 1 I 1 1 \ AAAA n C 1 I EA f I} i j BUILDING 1 1 J�( 1 \ 01 /\ a 1 I \ I \ 1 , / / I 1 1 �• I I 1 I 605.8 1 1 I`, 'h' 1 o BFE= I\ 1 1. `.' FLUSH CURB 'J.� �1 • �1.9 "., a 60E-2 \ 1 I \ 1 I \ . t �t'i I ¢`4 WN GREEN * \ I I 4 \• r< , t' .�..:' } �• 1 \ V \ I f I i LI �¢J, i I I I I- �. ' J' ::< NEW 20' RWSA 1 �j� J �r. \ 7. EP IDENTIAL > I I I i �.y k� •\. \�1 EASEMENT TRANS e. N AREA / 1 I I 1 I I 1 /I I `... � - 1 I x 11.7 \ , 1 \ II \ / li I' is I I 1 1 11 .l.•:::;i\ �\ 1 - - - - - - - - �86 �j4 I. \ / 1 I 1 I(/ ) I 1 / , 1 I I I i ,� I I I \I CHAINLINK FENEr 0 A INSET SCALE: � I 1.XI ixs ..`�1 1 BENCHMARK \ 1 I �' (/ II i> tl 10s I 1 I 5 TI ` '•''�\TRAFFIC BOX \ 1 NOTES: 1. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 2. PROPOSED SITE ENTRANCE TO BE RIGHT -IN & RIGHT -OUT ONLY 3. RETAINING WALL DESIGN TO BE SUBMITTED UNDER SEPARATE COVER, BY OTHERS. 4. ALL RETAINING WALLS OVER 30 INCHES TALL WILL HAVE HANDRAILS OR SAFETY FENCE WHERE APPLICABLE. 5. CONTRACTOR IS TO CONTACT ACSA 3 DAYS PRIOR TO TYING SEWER MANHOLE, TO SCHEDULE AN INSPECTOR ON SITE. 6. EXISTING ACSA WATERLINE IS A CRITICAL WATERMAIN AND CARE SHOULD BE TAKEN NOT TO DISTURB THE LINE DURING CONSTRUCTION. EXISTING 12' ACSA EASEMENT TO BE VACATED. NEW 20' ACSA EASEMENT TO BE CENTERED OVER PIPE. 6. THE ENTIRE TRAVEL WAY ON THE PROPERTY IS DESIGNATED AS A FIRE LANE. 7. A KNOX BOX WILL BE PROVIDED - LOCATION TO BE APPROVED BY THE FIRE CODE OFFICIAL. 8. SPOT SHOTS SHOWN INDICATE FLOW LINES 9. LIMITS OF CLEARING CAN BE FOUND ON THE EROSION CONTROL PLAN 1 , - ELEVATION=614.7 1 ENTRANCE GRADING DETAIL I } INSET SCALE: 1 ":10' LIGHA P LE &/ ! PROP. �WM / /� / I 1: :..: STAMPED CONCRETE 1 / I / OVE�FIEA I I t ._ R EASEMENT / CA QP�Y TYP)1 / / /� BUILDING FACE _ JI ;;.`' ':;Xi��b a 1I1 NEW 20' A / I // // / 12" ASSUMED 14.0 / / 1 / INSIDE FOOTER / ..: EASEMENT ;.'i Y:?.. ( \ / / l i I >I 10.0 i . � / RI�I{cP / \ / CONS EX. VEPCO EASEMENT THE EXISTING ACSA WATERLINE IS / ' r' %� _+'t'.� A CRITICAL WATERMAIN AND CARE / // ,� \ I cpp�?a f x.... `s' a 6045(�- SHOULD BE TAKEN NOT TO DISTURB'? / ' I I \ 99 �A� / L ` THE LINE DURING CONSTRUCTION. EXISTING 12' ACSA EASEMENT TOTMP 60-76B E MICHAEL & MELINDA �\ I I w \�(_ C, �� ,• BE VACATED. NEW 20' ACSA / SPRINKEL/�.; , •:.; Ja EASEMENT TO BE CENTERED OVER ZONED: RA I I " ��a USE: �ESIDENTI/�L PIPE. �` I I I / / / Imo/ \ , .' /PROP. 1.5" DL.,,_STIC CONNECTION H �'ls� I I I I Uj / 1.5" MET &BOX 0000000000 / I / RETAINING WALL #3: 6' MAX. i> SEE NOTE 3 & 4 THIS SHEE% • 0) FFH O \O`b' .9 .6 a 1` .e 11 RED-IROCK WALL, VEHICLE BARRIER ATOP, 2' OVERHANG 1Cj.b �03 e . a. o a a , rn a zU w U) m UvN OZ z (0 Y Q V] J H0) maw O Q � J = Ir r OU ¢> m dz =w Q 0 `0 W ON Wo °a Q J Z v U Z� ¢_ 0 > N w (5 0 Z m N a¢ I w N w "FQi`JI'' Q Z J > O U Ly d J J CO } 000 O a=zw OU w/ W w O �Q rn= rn U Z 0 F- rn O� 00 Z Z > > 00 w � � v W O O Z �Lzx of vf�c /1 / 2• u ` 17 y y Jimmy L. Taggart Lic. No. 22641 sn '�o�, W 08/03/2020 1{ ESSIONAL �\yG U_ J Q g Z ,LU 5 J 0 z w a = Q W W a a o W ( m z > Za o w Z X L.L D fr 0 O ! V DATE: 10-25-2019 SCALE: 1 ":20' JOB: 19.0125 SDP-2019-00062 SHEET: 6 OF 13 r/ R \ � i � � I I v 625 620 615 610 605 94 I NOTES 1. PROPOSED SITE ENTRANCE TO BE RIGHT —IN AND RIGHT —OUT ONLY, THEREFORE ONLY LEFT SIGHT DISTANCE PROFILE IS PROVIDED. 2. SIGHT DISTANCE REQUIREMENTS FROM VDOT APPENDIX F, TABLE 2-5: 2.1. SDR 5 LANE MAJOR ROAD (CONTINUOUS TWO—WAY TURN LANE) = 465 FEET PROVIDED:465 FEET ON PLAN VIEW ONLY 2.2. SDL 5 LANE MAJOR ROAD (CONTINUOUS TWO—WAY TURN LANE) = 440 FEET PROVIDED: 440 FEET J. LANDSCAPING PLANTS AND TREES ADJACENT TO THE SIGHT DISTANCE TRIANGLE WILL NEED TO BE MAINTAINED IN AREA BETWEEN 2 AND 7 FEET ABOVE THE GROUND AS A CLEAR ZONE TO PRESERVE SIGHT LINES AND ACCOMMODATE PEDESTRIANS SIGHT DISTANCE LEFT PROFILE PROFILE 1 - � aa�L'S11:1ilP11:QI)l��111:1■ � • L a �aaex.�:�ansncm�ea� --Illy -�:iQ1QClilJlh.7:111i91.`111ii111:h.UN17 Cl♦ 1i:16`IIII[lid:h_111i - � VERTICAL PROFILE SCALE: 1 "=10' HORIZONTAL PROFILE SCALE: 1 "=30' II \ \ \ 11 if LANDSCAPING PLANTS AND TREES ADJACENT TO THE SIGHT DISTANCE TRIANGLE WILL NEED TO BE MAINTAINED IN AREA BETWEEN 2 AND ' 7 FEET ABOVE THE GROUND AS A CLEAR ZONE TO PRESERVE SIGHT LINES AND — ACCOMMODATE PEDESTRIANS 1 � ----- - --------- — L J ------------- — SIGHT DISTANCE EYE HEIGHT 3.5FT DECISION POINT REQUIRED SIGHT DISTANCE LEFT 440 FT — — — If 1 1 1 zw 1 WN _ 1 'INd I� -_ L-- W li Q ��W \ � U � ----------- TO GEOk OAD � Va�a� .r 625 620 615 610 605 50 1 i r � Y � \ 30 0 30 60 90 / / SCALE: 1 "=30' J m U 6 m W w D N U Z zco dN O ONf J Q 00)) aQw U T J = Qi 00 aU m aZ =w ir pv) Wo D -1 �T ° aZ vU Z� (A > o �j o W W 0 cn O Z rn (E > No v (L w QW`JI" Q Z J > O pair a }_co>� Z W O O W W �a rn = rn O Z 0 u o� F-F- Z z 00 v u Z Z 00 0 0 0 0 a Z r N ��o�D rc2JitQ22841 �'04 U_ J Q a z z M 5 -, Q� v> a �= a J W a o �zm C04 J Q U Z 0 < 0 LL c Q Z A c ~ O O 0 DATE: 10-25-2019 SCALE: 1 ":30' JOB: 19.0125 SDP-2019-00062 SHEET: 70F 13 I, WP-2 3" IM 19, OVERLAP ADJACENT TRAVEL LANE ASPHALT PAVEMENT WIDENING EXISTING ASPHALT LAYERS 2" SM 12.5 12x EDGE OF ExISING PAVEMENT (AS DETERMINED N FIELD) PER SIGNED AND SEALED TACK COAT THE PROPOSED PAVEMENT DESIGN, ON 4" CONSTRUCTION JOINT EXISTING ASPHALT LAYERS PROPOSED ASPHALT LAYERS LAYER OF BM 25 SAW CUT AND ENSURE EXISTING SUBBASE PROPOSED SUBBASE EXISTING ASPHALT EDGE - - - - - - - - - - - - - - - - - - - - - - MATCH BOTTOM OF IS SOUND, TACK PER COMPACTED SUBGRADE EXISTING STONE BASE, SPECIFICATIONS THICKNESS - 12" MIN CONSTRUCTION JOINT DETAIL 21" MAX. ® REMOVE EXISTING ASPHALT LAYERS TO EXISTING SUBBASE AND REPLACE WITH PROPOSED ASPHALT WIDENING LAYERS ® PROPOSED MINIMUM 11/,, NCH THICK ASPHALT SURFACE COURSE (SEE NOTE 5) A MINIMUM 12 INCHES, OR GREATER AS NECESSARY TO ABUT THE FULL THICKNESS OF EXISTING ASPHALT LAYERS AS DETERMINED BY CORES (SEE NOTE 3) NOTES: 1, ASPHALT PAVEMENT WIDENING SHALL HAVE A PAVEMENT DESIGN IN ACCORDANCE WITH CURRENT VDOT PROCEDURES AND BE APPROVED BY THE ENGINEER. 2. THE PAVEMENT DESIGN FOR ASPHALT PAVEMENT WIDENING SHALL MEET OR EXCEED THE DEPTHS AND TYPES OF THE LAYERS O EXISTING PAVEMENT. SUBSURFACE DRAINAGE OF THE EXISTING MID PROPOSED PAVEMENT SHALL BE ADDRESSED N THE PAVEMENT DESIGN. 3. A MINIMUM OF THREE CORES SHALL BE TAKEN ALONG THE CENTER OF THE ADJACENT TRAVEL LANE TO DETERMINE THE TYPE AND THICKNESS O EXISTING PAVEMENT LAYERS. THESE CORES SHALL BE SPACED NO MORE THAN 500 FEET MART. 4. THE ADJACENT TRAVEL LANE SHALL BE MILLED A MINIMUM DEPTH OF 112 INCHES AND REPLACED WITH AN ASPHALT SURFACE COURSE TO MATCH THE PROPOSED PAVEMENT WIDENING SURFACE COURSE, UNLESS WAVED BY HE ENGINEER. 5. THE ENGINEER MAY REQUIRE THE MILLING DEPTH O THE EXISTING PAVEMENT TO BE ADJUSTED TO ACHIEVE AN ACCEPTABLE PAVEMENT CROSS -SLOPE AND EFFECTIVE SURFACE DRAINAGE. 6. EXISTING PAVEMENT MARKINGS AND MARKERS WITHIN THE PROJECT LIMITS SHALL BE RESTORED SUBJECT TO THE APPROVAL O THE ENGINEER. 7. FINAL TRANSVERSE PAVEMENT TIE-IN SHALL CONFORM TO THE REQUIREMENTS OF SECTION 315 OF THE SPECIFICATIONS EXCEPT THAT ALL JOINTS AT TIE-IN LOCATIONS SHALL BE TESTED USING A 10 FOOT STRAIGHTEDGE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 315 OF THE SPECIFICATIONS. `" ASPHALT PAVEMENT WIDENING ROAD AND BRIDGE STANDARDS SHEET I OF 1 REVISION DATE FOR WIDENING SUBJECT TO TRAFFIC 303.02 VIRGINIA DEPARTMENT O TRANSPORTATION 2016 ROAD & BRIDGE STANDARDS D A n 2" - '�. 1' R D.e SURFACE p.' .A.' BASE C Q SUBBASE NOTES( 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 F CAST N PLACE, 4000 PSI IF PRECAST, 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (LONG FACE OF CURB) WILL BE PAD FOR AS RADIAL CURB. 4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" (13" DEPTH) OR INCREASED AS MUCH AS 3" U9" DEPTH) IN ORDER THAT THE BOTTOM OF THE CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE, THE DEPTH IS TO BE 16" AS SHOWN. NO ADJUSTMENT IN THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE IN DEPTH. S. CG-3 IS TO BE USED ON ROADWAYS MEETING THE REQUIREMENTS FOR CG-7 AS SHOWN N APPENDIX A OF THE VOOT ROAD DESIGN MAMA N THE SECTION ON GS URBAN STANDARDS, 6, WHEN THIS STANDARD IS TO BE TIED INTO EXISTING BARRIER CURB. THE TRANSITION IS TO BE MADE WITHN 10' OR THE CHANGE N STANDARDS CAN BE MADE AT REGULAR OPENINGS. SPECIFICATION STANDARD 4" CURB FE EANCEE ROAD AN`RIv BRIDGESTANDARDSSTTANDARDS VIRGINIA DEPARTMENT OF TRANSPORTATION IDS 502 SHEET 1 OF 1 REVISION DATE 2GL02 NOTE+WHEN A PEDESTRIAN ACCESS ROUTE CROSSES A COMERCIAL ENTRANCE ( THE CROSSSHALL BE 2X FOR O 5 FE A� TO BE I o I MAINLINE APPROACH (SEE SURFACING 3) (RADIUS AS SHOWN ON PLANS) C rn (RADIUS TO BE AS _ SHOWN ON PLANSI CG-2 OR CG-e - - - / J - - - B r• 0 SIDEWALK SIDEWALK (SEE - NOTE 5) ¢ I OPTIONAL UNPAVED SPACE FLOW LINES >%PANSION ---- Q t---- JOINT NOTE: WIDTH "B" 2'-O" OR AS a -I c•I MAINLINE ROADWAY SHOWN ON TYPICAL SECTION. A PLAN VIEW MAINLINE ROADWAY SLOPE 10'PARABOLIC CURVE (ENTRANCE ONLY) SPECIFICATION REFERENCE 315 GENERAL NOTES 1. WHEN USED IN CONJUNCTION WITH STANDARD CG-3 OR CG-7, THE CURB FACE ON THIS STANDARD IS TO BE ADJUSTED TO MATCH THE MOUNTABLE CURB CONFIGURATION. 2. SEE STANDARD CG-12 FOR CURB RAMP DESIGN TO BE USED WITH THIS STANDARD. 3. MAINLINE PAVEMENT SHALL BE CONSTRUCTED TO THE R/W LINE (EXCEPT ANY SUBGRADE STABILIZATION REQUIRED FOR MANLIKE PAVEMENT WHICH CAN BE OMITTED IN THE ENTRANCE.) 4. RADIAL CURB OR COMBINATION CURB AND GUTTER SHALL NOT BE CONSTRUCTED BEYOND THE R/W LINE EXCEPT FOR REPLACEMENT PURPOSES. ENTRANCE NOTES 5. WHEN THE ENTRANCE RADII CANNOT ACCOMMODATE THE TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK TRAFFIC, THE DEPTH FOR SIDEWALK & CURB RAMPS WITHIN THE LIMITS OF THE RADIISHOULD BE INCREASED TO 7". (SEE CGS3) EDGE OF PAVEMENT OR OPTIONAL FLOW LINE 8% MAX. GRADE CHANCE ® _ D - 6. PLANS ARE TO INDICATE WHEN CONSTRUCTION OF A FLOW U (SEE LINE IS REQUIRED TO PROVIDE POSITIVE DRAINAGE ACROSS MANLIKE ROADWAY - - - - - - - - - - - - NOTE 7) THE ENTRANCE. 8X MAX. ® D 7. THE DESIRABLE AND MAXIMUM ENTRANCE GRADE CHANGES GRADE CHANGE 0" ARE LISTED IN THE ALLOWABLE ENTRANCE GRADE D TABLE. THESE VALUES ARE NOT APPLICABLE TO STREET CONNECTIONS, 5' M 20' MINNUM FOR COMMERCIAL ENTRANCE INTERSECTION NOTES 8. WHEN CG-111S USED FOR STREET CONNECTIONS. THE ® CONSTRUCT GRADE CHANGES WITH A PARABOLIC CURVE. CONNECTION MUST BE DESIGNED IN ACCORDANCE WITH AASHTO POLICY AND THE APPLICABLE REOUIREMENTS SECTION A - A OF THE ROAD IALUEGN REOUIREMENTSG STOPPING SIGHT DISTANCE AND K VOT 9. OPTIONAL FLOWLINE MAY REOIBRE WARPING O A PORTION OF GUTTER TO PROVIDE POSITIVE DRAINAGE B ACROSS THE INTERSECTION. ALLOWABLE ENTRANCE GRADE CHANGES SECTION C-C ENTRANCE VOLUME GRADE CHANGE "D" DESIRABLE MAXIMUM HGH MORE THAN 1500 VPD 0 % 3 % MEDIUM 500-1500 VPD 5 3 % 6 % LOW LESS THAN 500 VPD Project: Date: Street ( or section): Testing Firm: Testing Date(s): Design ADT Average Daily Traffic, or VPD Present Year: Design Year: Growth Rate (%): Design ADT at Design Year: Percent Trucks: Design Traffic Volume: Design Pavement Index: Flexible Pavement Design Evaluation Worksheet 28-Jul-20 Office parking lot (assumed fordesign purpose) Soil Support Measured CBR Results: 0- VDOT Entrance Design Project: Georgetown/Hydraulic Location: Albemarle County Date: 1-Oct-19 Description of Existing Use: Unimproved, Urban, Partially wooded Description of Proposed Use: Office Building Connecting Roadway: Hydraulic Road SR743 Functional Classification: Urban Collector Design Speed: 35 mph Trip Generations ITE Code Quantity Units Existing N/a N/a N/a Current Proposed (Use posted) Peak %AM %AM Period Rate in out Daily AM r VPD Peakt AM AM In Out Gen. Office 710 9.376 KSF Net Office Space 1.16 86% 14% 9.74 91 11 9 2 0 0.0 0 0 Measured CBR Average: 5 Future 0 0 0% 0% o 0 0.0 0 0 Design CBR: 3.3 Resiliency Factor 1 Proposed Total 91 11 9 2 Soil Support Value 3.3 Estimated Splits 6.7 Total Proposed Thickness Index: 8.6 Southbnd 100% Right toward Rt 29 Southbnd Northbnd 0% Left -turn forbidden for this Project Northbnd Surface Asphalt Concrete (SM-2A,B, orC) (Superpave SM-9.5A) Prime & Double Seal or Blotted Seal Surface Intermediate Asphalt Concrete (IM-1Aor 1B)(Superpave IM-19.OA) Base 1 Asphalt Concrete (BM-2 or BM-3)(Superpave BM-25.0) Full Depth Asphalt Concrete (BM-2 or BM-3) over Surface Untreated Aggregate (21A or 21 B) Cement Treated Aggregate Cement Treated Select Material, Type II, min. CBR=20 Select Material Type I & II, non -plastic, min CBR = 30 Select Material Type II, non -plastic, min CBR = 20 Soil Cement Cement Treated Select Material, Type II Cement Treated Select Borrow Base 2 Untreated Aggregate (21A or 21 B) Cement Treated Aggregate Select Material Type I, non -plastic, min CBR = 30 Select Material Type I & II, non -plastic, min CBR = 20 Soil Cement Soil Lime Cement Treated Select Material, Type II Cement Treated Select Borrow OK Material Equivalency Min. Max. Truck volume Thickness, (h) Value, (a) Inches Inches (a x h) 0°i0 (Estimated by RGA) Office parking lot only Southbnd Northbnd 1.5 1.67 1 1.5 2.5 Existing Highway Traffic 0 0.84 0.0 Source: Albemarle Traffic Date 2017 Highway: Hydraulic Road SR743 1.67 2 2 0.0 AADT= 23000 VPD 1.5 1.67 2.5 4 2.5 2&4 Tire Vehicles 98% or 22540 VPD Directional Factor (D)= 0.5189 or 11935 VPD in referenced direction Northbnd 0 1.60 6 0.0 Peak Hour Factor (k)= 0.0981 or 2256 VPH 1.00 6 6 0.0 0 1.67 6 6 0.0 Left Turn Analysis 0 1.50 6 F 6 0.0 Northbnd is Advancing direction 0 0.84 6 F 6 0.0 Design speed= 35 Posted 0 0.60 6 F 6 0.0 AADT= 23000 (see above) Peak H_our(K)= 0.0981 (see above) 0 1.00 6 6 0.0 Peak Hr. Volume= 2256 (AADTx K) 0 1.17 6 6 0.0 Advncing Directional Factor (Da)= 0.519 Percentage approaching site in direction requiring left turn into site 0 1.00 6 6 0.0 Advancing Volume= 1171 (AADT x K x Da) Opposing Directional Factor (Do)= 0.4811 Percentage approaching site in direction requiring right turn into site 6 0.60 4 8 3.6 Opposing Volume= 1086 (AADT x K x Do) Left Turn %= 0% Entrance is Right -in Right -out only 0 1.33 4 8 0.0 - 0 0.50 4 8 0.0 Using 1086 VPD opposing volume, and OPeak hour into site x advancing "K" factor 0 0.40 4 8 0.0 an advancing volume= 330 VPH is the warrant figure requiring a left turn lane 0 _ 1.00 6 8 0.0 Therefore, A left turn lane is required. (Ref. VDOT, See chart) 0 0.92 6 8 0.0 Left turn into the Site is forbidden for this project. + _ 0 1.17 6 8 0.0 Right Turn Analysis _ 0 1.00 6 8 0.0 Southbnd is Advancing direction PHV Approach Total= 1086 Peak hour volume approaching site in direction requiring right turn into site Total Proposed Thickness Index: 8.6 PHV Right Turn Volume=®(AM-in trips from Advancing direction (see Estimated Splits above)) Using 1086 VPD approach volume, and 11 Right turns into site No Right Turn or Taper is Required. (Ref. VDOT, See chart) However, 80'taper is proposed in accordance with the General Development Plan PER GENERAL I CONCRETE SIDEWALK DEVELOPMENT 4"- 3000 PSI PLAN OL e" NOTE: PER GENERAL DEV. 4" VDOT 21A PLAN, 9' SIDEWALK TO OVER COMPACTED BE ADDED BEHIND SUBGRADE EXISTING SIDEWALK PROPOSED SIDEWALK DETAIL NOT TO SCALE NOTES: I. THIS ITEM MAY BE PRECAST OR CAST N PLACE, 2. CONCRETE TO BE CLASS A3 F CAST IN PLACE. 4000 PSI IF PRECAST. 3- CURB HAVING A RADIUS O 300 FEET OR LESS (ALONG FACE OF CURB) WILL BE PAID FOR AS RADIAL CURB. THE DEPTH O CURB MAY BE REDUCED AS MUCH 4 AS 3" (IS" DEPTH) OR INCREASED AS MUCH AS 3" (2T' DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWISE, THE DEPTH IS TO BE IS" AS SHOWN. NO ADJUSTMENT N THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE N DEPTH. 5 CG-2 IS TO BE USED ON ROADWAYS MEETING THE REQUREMENTS FOR CG-6 AS SHOWN IN APPENDIX A O THE VDOT ROAD DESIGN MANUAL. IN THE SECTION ON GS URBAN STANDARDS. ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED v D.; t . D G Dom, D.;,o D,;TD.LTD A D D•;TD•;TD n' ,a D- D•' ' D R SURFACE 1 A' E SUBBASE PAVEMENT DESIGN NOTE: ROAD DESIGN IS BASED ON ASSUMED CBR OF 5. FINAL PAVEMENT SECTION TO BE DETERMINED FOLLOWING FIELD CBR TEST OF IN SITU SUBGRADE. 1.5" SM 9.5A 1.5" BM 25.0 SLOP 6" VDOT 21A� COMPACTED SUBGRADE PER GEOTECHNICAL ENGINEER REQUIREMENTS TYPICAL PARKING LOT DETAIL: 91 VPD 2" R i D ` o A • ff r 2'-0" -THIS AREA MAY BE CONCRETE AT THE OPTION OF THE CONTRACTOR Source ITE 10th Ed. CG-6 NOTES: 1. THIS ITEM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 IF CAST IN PLACE, 4000 PSI IF PRECAST. 3, COMBINATION CURB & GUTTER HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) SHALL BE PAD FOR AS RADIAL COMBINATION CURB & GUTTER. 4. FOR USE WITH STABILIZED OPEN -GRADED DRANAGE LAYER, THE BOTTOM OF THE CURB & GUTTER OF SUBBASE COURSESBE AND TO PARALLEL TO TDEPTH OF THE THE PAVEMENT, 5. ALLOWABLE CRITERIA FOR THE USE OF CG-6 IS BASED ON ROADWAY CLASSIFICATION AND DESIGN SPEED AS SHOWN IN APPENDIX A OF THE ROAD DESIGN MANUAL N THE SECTION ON GS URBAN STANDARDS. .• n • a D - • THE BOTTOM OF THE CURB AND GUTTER MAY BE CONSTRUCTED PARALLEL TO THE SLOPE O SUBBASE COURSES PROVIDED A MINNUM DEPTH O 7" IS MAINTAINED. NOTE: ALLOWABLE ENTRANCE GRADE TABLE IS NOT SPECIFICATION APPLICABLE TO STREET CONNECTIONS REFERENCE 1I `v�T SPECIFICATION IFICATION STANDARD 6 CURB ROAD AND BRIDGE STANDARDS REFERENCE n ERENCE METHOD OF TREATMENT �VD°T 105 REVISION DATE SHEET I OF 1 COMBINATION 6 CURB AND GUTTER ROAD AND BRIDGE STANDARDS 502 VIRGINIA DEPARTMENT OF TRANSPORTATION 105 502 (CONNECTION FOR STREET INTERSECTIONS AND COMMERCIAL ENTRANCES) REVISION DATE SHEET I OF 1 201.01 502 VIRGINIA DEPARTMENT O TRANSPORTATION VIRGINIA DEPARTMENT O TRANSPORTATION 07/15 203.04 ROAD AND BRIDGE STANDARDS REVISION DATE SHEET 1 OF 1 201.03 rn U g m w U) o C) U -° Z z U) N O0(D �Y> tf)J am <IJ C5 T J = Q( OU a� m w Ctd m055 IrO W OQIE �Q rQ�1 _J v 0 ZO 3: Oco � o Z�j Lu o LL Z �'V/) 0 Z rn 1- [L aW a w Q z > O vaiw a J 0 U) Oazw A/ UIZ U 0 FG� w to Q rn= rn U z 0 rA C� z z 0 0 z z 0 0 U U 0 0 N N a n 0 0 z H N ��o���DyTH Op `rpc� U 9'7 y Jimmy L. Taggart Lic. No. 22841 A�OF 07/31/2020 144j� ESSIONAL �tyG J Q Q I-1 co Z z °C _J °C Q > a= forw �zLL2I 5 LN<.1 W J � Q O Q O Z W X z c� U_ (D �p �. Icr O rO EI V DATE: 10-25-2019 SCALE: 1 ":20' JOB: 19.0125 SDP-2019-00062 SHEET: 8 OF13 r VDOT STANDARD NOTES: 1. TRIP GENERATION DATA: USE: GEN. OFFICE ITE CODE: 710 DAILY TRIPS: 91 VPD 2. ALL CONSTRUCTION METHODS AND MATERIALS WITHIN STATE MAINTAINED RIGHT OF WAY SHALL BE IN ACCORDANCE WITH CURRENT VDOT STANDARDS, SPECIFICATIONS, CURRENT "WORK AREA PROTECTION MANUAL", AND ALL APPLICABLE LOCATION AND DESIGN INSTRUCTIONAL AND INFORMATIONAL MEMORANDUM. INSPECTION DOCUMENTATION BEST PRACTICES MANUAL. 3. A LAND USE PERMIT SHALL BE OBTAINED FROM VDOT BEFORE ANY CONSTRUCTION IS STARTED WITHIN STATE MAINTAINED RIGHT OF WAY LIMITS, INCLUDING ACCESS. ALL LAND USE PERMIT APPLICATIONS MUST HAVE TWO (2) SETS OF APPROVED PLANS, A COPY OF THE PLAN APPROVAL LETTER A CHECK FOR THE PROCESSING FEE MADE PAYABLE TO TREASURER OF VIRGINIA AND SURETY OR BOND IN THE REQUIRED AMOUNT. 4. IN ACCORDANCE WITH THE PROVISIONS OF THE INSPECTION DOCUMENTATION BEST PRACTICES MANUAL, VDOT SHALL BE NOTIFIED PRIOR TO THE START OF ANY WORK WITHIN STATE MAINTAINED RIGHT OF WAY. THE CONTRACTOR WILL COORDINATE WITH THE VDOT POINT OF CONTACT AT SIGNIFICANT STAGES OF THE PROJECT. 5. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER WHO SEALED THE PLANS TO VERIFY THE APPROVAL OF THE PLANS BY ALL APPLICABLE FEDERAL, STATE, AND LOCAL AGENCIES. 6. THE CONTRACTOR SHALL HAVE AVAILABLE A COPY OF THE LAND USE PERMITS FINAL APPROVED PLANS ANY APPROVED REVISIONS AND A COPY OF THE APPROVAL LETTER ON SITE. 7. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC., PRIOR TO CONSTRUCTION. 8. ANY ERRORS, CONFLICTS, OR DISCREPANCIES FOUND ON THE APPROVED PLANS SHALL BE REPORTED TO THE ENGINEER WHO SEALED AND SIGNED THE PLANS. VDOT SHALL BE NOTIFIED FOR RESOLUTION BEFORE PROCEEDING FURTHER WITH THE WORK, IF THE STATE MAINTAINED RIGHT OF WAY IS AFFECTED. 9. DESIGN CHANGES, SPECIFIED MATERIAL CHANGES, AND/OR FIELD CHANGES FROM THE APPROVED PLANS SHALL BE RESUBMITTED TO VDOT FOR REVIEW AND APPROVAL, PRIOR TO PROCEEDING WITH THE WORK. 10. THE DEVELOPER IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING ROADS, UTILITIES, AND ANY OTHER INSTALLATIONS ALREADY IN PLACE WHICH OCCUR AS A RESULT OF PROJECT CONSTRUCTION WITHIN OR CONTIGUOUS TO STATE RIGHT OF WAY LIMITS. 11. THE COMMONWEALTH TRANSPORTATION BOARD, MEMBERS OF THE BOARD, THE COMMONWEALTH AND ALL COMMONWEALTH EMPLOYEES, AGENTS, AND OFFICES, SHALL BE ABSOLVED FROM ALL RESPONSIBILITIES, DAMAGES AND LIABILITIES AS A RESULT OF WORK ARISING FROM THE EXERCISE OF THE PRIVILEGES GRANTED BY PLAN AND/OR PERMIT APPROVAL. 12. NO STRUCTURE SHALL BE CONSTRUCTED ON VDOT RIGHTS OF WAY UNLESS SHOWN ON VDOT APPROVED CONSTRUCTION PLANS OR COVERED BY A VDOT LAND USE PERMIT. 13. VDOT SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF ANY STORMWATER MANAGEMENT FACILITY OR OUTFALL STRUCTURE LOCATED OUTSIDE OF STATE MAINTAINED RIGHT OF WAY LIMITS AND SHALL BE ABSOLVED FROM ALL RESPONSIBILITIES, DAMAGES AND LIABILITIES AS A RESULT OF SUCH. 14. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR IN ACCORDANCE WITH THE VIRGINIA EROSION & SEDIMENT CONTROL HANDBOOK AND VIRGINIA STORMWATER MANAGEMENT PROGRAM. AN INDIVIDUAL CERTIFIED BY THE VIRGINIA DEPARTMENT OF CONSERVATION AND RECREATION, HOLDING A RESPONSIBLE LAND DISTURBER CERTIFICATION, SHALL BE IN CHARGE OF THE LAND DISTURBING ACTIVITY AND ON THE WORK SITE AT ALL TIMES. 15. VDOT SHALL BE CONTACTED TO VERIFY SUBGRADE COMPACTION BY TEST ROLE PRIOR TO THE PLACEMENT OF BASE MATERIAL. WHEN UNSUITABLE MATERIALS FOR SUB -GRADES AND OTHER ROADWAY CONSTRUCTION ARE ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL CONTACT A GEOTECHNICAL ENGINEER AND VDOT. SUCH MATERIALS SHALL BE UNDERCUT AND BACKFILLED AS DIRECTED BY A GEOTECHNICAL ENGINEER, ACCORDING TO VDOT SPECIFICATIONS. 16. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS ACCORDING TO VDOT "ROAD AND BRIDGE SPECIFICATIONS". 17. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE SHALL BE REQUIRED PER VDOT STANDARDS AND SPECIFICATIONS. 18. VDOT SHALL HAVE APPROVED ALL BASE COURSES FOR DEPTH AND TEMPLATE AND PERFORMED THE REQUIRED VISUAL, PROOF ROLL, COMPACTION, AND ANY ADDITIONAL INSPECTIONS AS DETERMINED BY THE VDOT INSPECTOR PRIOR TO PLACEMENT OF ANY SURFACE COURSES. 19. IF THE DEVELOPER CHOOSES TO PROVIDE VDOT WITH DOCUMENTATION BY A LICENSED GEOTECHNICAL ENGINEER, CERTIFYING THAT ALL IN -PLACE PAVEMENTS MEET OR EXCEED THE APPROVED PAVEMENT DESIGN THICKNESS PRIOR TO VDOT ACCEPTANCE FOR MAINTENANCE, THE CERTIFYING DOCUMENTATION SHALL CONFORM TO VDOT SPECIFICATIONS AND THE APPROVED PLANS. 20. INSTALLATIONS OF PIPE CULVERTS AND STORM SEWERS SHALL CONFORM TO VDOT STANDARD PB-1. 21. ALL FIXED OBJECTS SUCH AS UTILITY CABINETS, PEDESTALS, AND STREETLIGHTS SHALL BE LOCATED IN ACCORDANCE WITH CLEAR ZONE REQUIREMENTS, AS NOTED IN THE ROAD DESIGN MANUAL. THERE SHALL NOT BE ANY CABINETS, PEDESTALS, OR FIRE HYDRANTS LOCATED ON THE SHOULDER. 22. FLOWERS, SHRUBS, AND TREES SHALL NOT BE PLACED WITHIN STATE MAINTAINED RIGHT OF WAY LIMITS WITHOUT AN APPROVED SET OF PLANS AND AN APPROVED PLANTING AGREEMENT. NO IRRIGATION (SPRINKLER) SYSTEMS, BRICK COLUMNS, ENDWALLS, AND/OR BRICK MAILBOXES WILL BE CONSTRUCTED OR INSTALLED WITHIN STATE MAINTAINED RIGHT OF WAY LIMITS WITHOUT A PERMIT. ANY OF THE ABOVE ITEMS FOUND IN THE RIGHT OF WAY WITHOUT A PERMIT SHALL BE REMOVED, AND ALL COSTS OF THE REMOVAL SHALL BE BORNE BY THE OWNER AND/OR DEVELOPER. 23.THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND AND OVERHEAD UTILITIES, WHETHER OR NOT THEY ARE SHOWN ON THE PLANS, PRIOR TO STARTING WORK. THE CONTRACTOR WILL BE RESPONSIBLE FOR REPAIRS, AT HIS OWN EXPENSE, OF ANY UTILITIES DAMAGED BY HIS CONSTRUCTION METHODS. MISS UTILITY MUST BE CONTACTED AT 811 AT LEAST 72 HOURS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. THE DEVELOPER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING OR PROPOSED RIGHT OF WAY. 24. ALL CONSTRUCTION DEBRIS, MATERIALS, DUMPSTERS, ETC. SHALL BE LOCATED OUTSIDE THE RIGHT OF WAY. 25. AUTHORIZED UNDERGROUND UTILITY INSTALLATIONS SHALL MAINTAIN A MINIMUM OF 36 INCHES OF COVER, INCLUDING UNDER DITCHES. 26. OVERHEAD UTILITY INSTALLATIONS WITHIN LIMITED ACCESS AND NON LIMITED ACCESS RIGHT OF WAY SHALL BE INSTALLED IN ACCORDANCE WITH VDOT LAND USE PERMIT REGULATIONS. 27.SIGHT DISTANCES AT ENTRANCES AND INTERSECTIONS SHALL BE MAINTAINED AT ALL TIMES DURING AND AFTER CONSTRUCTION. ANY OBJECT OR LANDSCAPING THAT OBSTRUCTS DRIVER VIEW SHALL BE RELOCATED AT THE DEVELOPER'S EXPENSE OR THE ENTRANCE MAY BE CLOSED AT VDOT'S DISCRETION. 28. THE PERMITEE IS RESPONSIBLE FOR PURSUING AND OBTAINING ANY AND ALL ENVIRONMENTAL PERMITS INCLUDING, BUT NOT LIMITED TO, WETLANDS, WATERS OF THE US, WATER QUALITY, THREATENED AND ENDANGERED SPECIES, HAZARDOUS MATERIALS, AND CULTURAL RESOURCES, REQUIRED TO PURSUE THE PROPOSED ACTIVITY BEFORE ANY CONSTRUCTION IS STARTED WITHIN STATE MAINTAINED RIGHT OF WAY LIMITS. DOCUMENTS RELATED TO THESE ACTIVITIES SHALL BE SUBMITTED WITH THE LAND USE PERMIT APPLICATION. 29. VDOT AND COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY FOR ACCEPTANCE FOR VDOT MAINTENANCE OR COMMERCIAL ENTRANCE TO A STATE MAINTAINED ROAD. MAINTENANCE OF TRAFFIC NARRATIVE: THE MAINTENANCE OF TRAFFIC IS OF CRITICAL CONCERN IN ALL ROADWAY IMPROVEMENT PROJECTS. IT IS IMPERATIVE THAT AN ESTABLISHED TRAFFIC CONTROL PLAN REMAIN IN PLACE FOR THE DURATION OF THE PROJECT. THIS PROJECT IS IDENTIFIED AS A MODIFIED VERSION OF "STATIONARY OPERATION ON SHOULDER", FIGURE TTC-4.0. THIS PROJECT PROPOSES TO ADD A COMMERCIAL ENTRANCE AT THE BEGINNING OF THE EXISTING RIGHT TURN TAPER LANE FOR SOUTHBOUND TRAFFIC ON HYDRAULIC ROAD (SR 743); APPROXIMATELY 233 FEET FROM THE INTERSECTION WITH GEORGETOWN ROAD (SR 656). ADDITIONALLY, THE EXISTING RIGHT TURN TAPER LANE WILL BE EXTENDED 80 FEET TO THE NORTH ON HYDRAULIC ROAD. THE WORK ZONE SHALL BE 145 FEET, STARTING AT THE BEGINNING OF THE PROPOSED RIGHT TURN TAPER LANE EXTENSION. THE WORK ZONE HOURS SHALL BE FROM 8pm-6am THE FOLLOWING MORNING. THE CONTRACTOR WILL MAKE ARRANGEMENTS TO STORE EQUIPMENT AND MATERIALS. RESIDENTS AND BUSINESS COMMUTERS WILL BE THE MAJOR TYPE OF TRAVELERS DURING THE DURATION OF THIS PROJECT. THE PROPOSED IMPROVEMENTS SHALL ALLOW CLEAR ACCESS BEYOND THE WORK ZONE TO ALLOW VEHICLES TO CONTINUE TO USE THE RIGHT TURN LANE ONTO GEORGETOWN ROAD. CONTRACTOR TO FOLLOW THE 2011 VIRGINIA WORK AREA PROTECTION MANUAL, REVISION 1, OR THE LATEST EDITION. NOTE CONTRACTOR TO USE THE SAME PRINCIPAL FOR SETTING UP THE WORK ZONE AS DEPICTED IN FIGURE TTC-16.2. THE EXISTING RIGHT -TURN TAPER WILL BE CLOSED AND CHANNELIZING DEVICES WILL BE USED ON THE SOUTH SIDE OF THE LANE CLOSURE TO ALLOW VEHICLES TO USE THE RIGHT TURN LANE BEYOND THE WORK ZONE. CONTRACTOR'S RECORD DRAWING REQUIREMENTS CONTRACTOR SHALL KEEP ACCURATE RECORDS OF ANY CHANGES SUBSTITUTIONS, ALTERATIONS, VARIATIONS OR UNUSUAL CONDITIONS ENCOUNTERED OR IMPLEMENTED WHILE ENGAGED ON THIS PROJECT. THESE RECORDS SHALL BE IN THE FORM OF 'REDLINES". 'REDLINES" SHALL REFER TO THE CONTRACTOR'S HAND ANNOTATIONS USING RED COLORED PEN/PENCIL TO DEPICT ACTUAL CHANGE, SUBSTITUTION, OR CONDITION. PRIOR TO CONTRACTOR REQUESTING PARTIAL OR FULL PAYMENT, CONTRACTOR SHALL PROVIDE THE OWNER WITH AN UP-TO-DATE CONTRACTOR'S RECORD DRAWING. SPECIFICALLY, THIS SET OF PLANS, ISSUED TO THE CONTRACTOR AS FINAL CONSTRUCTION DRAWINGS, SHALL BEAR THE 'REDLINE" MARKINGS LISTED BELOW AS WELL AS THE CONTRACTOR (AGENT OR SUPERINTENDENT) SIGNATURE AND CERTIFICATION BELOW: 1. REDLINES SHOULD ALWAYS BE ACCURATE NEAT, LEGIBLE, DATED AND REASONABLY SCALED. 2. ADD LARGE RED LETTERS TO TITLE SHEET WITH 'CONTRACTOR'S RECORD DRAWING' INCLUDING CONTRACTOR'S NAME, DATE, AND OTHER RELEVANT INFORMATION 3. CONTRACTOR'S REPRESENTATIVE OR SUPERINTENDENT SHALL INITIAL EACH SHEET. IF A SHEET HAS NOT BEEN CHANGED AT ALL OR NO MARK HAS BEEN ADDED, LABEL THE SHEET ONLY 'NO CHANGES' 4. IF A SHEET HAS BEEN CHANGED OR MODIFICATIONS HAVE BEEN ADDED, LABEL IT 'REVISED' 5. USE WRITTEN EXPLANATION TO DESCRIBE CHANGES. REFER TO SPECIFIC ACTIONS INSTEAD OF REFERENCING CHANGE ORDER NUMBERS OR RELATED DOCUMENTS 6. USE CLEAR LETTERING 7. NEVER REMOVE OLD VALUES OR DETAILS, JUST REDLINE OR "X" THROUGH THEM. IF THERE IS NO ROOM FOR THE NEW VALUE, YOU CAN GO TO THE SIDE AND REDLINE THE REPLACEMENT VALUE. 8. PROVIDE THE REDLINE DETAILS OF CHANGES OR ADDITIONAL INFORMATION, INCLUDING BUT NOT LIMITED TO FABRICATION, ERECTION, INSTALLATION, LOCATION, SIZING, MATERIAL, DIMENSION, ADDITIONS, RELOCATIONS, SUBSTITUTIONS, ETC 9. BE SPECIFIC WHEN MAKING NOTES TO UNDERGROUND UTILITIES, SHOWING EXACT LOCATION, DEPTH, AND MATERIAL USED (EXAMPLE: SEWER LATERALS) 10. PROVIDE ALL NECESSARY INFORMATION OF CONTRACTOR'S DESIGNED SYSTEMS OR SUBSTITUTIONS 11. CROSS OUT ANY PLAN REFERENCE TO "APPROVED EQUAL" AND REPLACE WITH ANY SPECIFIC INFORMATION OF VARIANCE USED DURING THE CONSTRUCTION PROCESS 12. ANY CHANGES IN INVERT ELEVATIONS, GRADE MODIFICATIONS, SLOPES, AND RELATED INFORMATION ON PIPING UTILITIES, EARTHWORK, ETC. SHALL BE REDLINED. 13. RECORD ALL UNEXPECTED OBSTRUCTIONS, COMPLICATING FACTORS, UNSUITABLE CONDITIONS FOUND IN THE PROJECT AREA INCLUDING ROCK, UNUSUAL TOPSOIL CONDITIONS, BURIED DEBRIS, ETC. 14. ATTACH OR INCLUDE ANY SHOW DRAWINGS OR SUPPLEMENTAL INFORMATION TO THE CONTRACTOR'S RECORD DRAWING 15. CHANGES MADE AS A RESULT OF ANY REGULATORY OR OWNER INSPECTION PROCESS CERTIFICATION STATEMENT: THIS HAND -MARKED SET OF DRAWINGS HAS BEEN 'REDLINED" TO PROVIDE ACCURATE DETAILED RECORD OF ANY SUBSTANTIVE CHANGES TO THE APPROVED DESIGN DRAWINGS. ANY ITEM NOT 'REDLINED" ON THIS PLAN SET OR SUBSEQUENT PAGES SHOULD BE CONSIDERED TO BE 'CONSTRUCTED IN ACCORDANCE WITH THE DESIGN AS SHOWN". NAME, TITLE FOR: DATE (CONTRACTOR) Page 6H-40 September 2019 Typical Traffic Control Outside Lane Closure Operation on a Four -Lune Roadnaq (Figure TTC-16.2) NOTES Standard: 1. On divided highways having a median wider than 8', right and left sign assemblies shall be required. Guidance: 2. Sign spacing should be 130W-1500'for Limited Access highways. For all other roadways, the sign spacing should be 500'-800' where the posted speed limit is greater than 45 mph, and 35W-500' where the posted speed limit is 45 mph or less. 3. When closing a lane, a PCMS should be used in advance of thefirst warning sign if all of the left side signs cannot he installed.' 4. Care should he exercised when establishing the limits of'the work --one to insure maximum possible sight distance in advance of the transition, based on the posted speed limit and at least equal to or greater than the values in Table 611-3. For Limited Access highways a minimum of 1000' is desired 5. All vehicles. equipment, workers, and their activities should be restricted to one side of the pavement. Standard: 6. Taper length (L) and channelizing device spacing shall beat the following: 7. Channelizing device spacing shall be at the following: 8. An arrow board shall be used when a lane is closed. When more than one lane is closed, a separate arrow board shall be used for each closed lane (see Figure TTC-18). 9. The buffer space length shall be shown in Table 6H-3 on Page 6H-5 for the posted speed limit. 10, A shadow vehicle with either a Type B or C arrow board operating in the caution mode, or at least one high intensity amber rotating, flashing, or' oscillating light shall be parked 80'-120' in advance of the first work crew. When the posted speed limit is 45 mph or greater, a truck - mounted attenuator shall be used. 11. Vehicle hazard warning signals shall not be used instead of the vehicle's high -intensity amber rotating, flashing, or' oscillating lights but can be used to supplement the amber rotating, flashing, or' oscillating lights. 12. When a side road intersects the highway within the TTC zone, additional TTC devices shall be placed as needed. O tion:' 13. PTRS and their supporting signs may be used. see Sections 6F.99 and 6G.25. Lone -term transverse rumble strips may be used in long -terns situations. see Section 6F.99 and TTC-20.' 14. The supplemental PTRS may be eliminated.' 1: Revision 1 - 4/1/2015 2: Revision 2 - 9/1/2019 (mph) Tape Length L Speed Limit (mph) Lane Width Feet Remarks Speed Limit (mph) Lane Width Feet Remarks 9 70 11 12 9 10 11 12 25 95 105 115 125 L=S�vY/so 50 450 500 550 600 L=SW 30 135 150 165 180 L=S�UVl60 55 495 550 605 660 L= SW 35 185 205 225 245 L=SRUV160 60 540 600 660 720 L=SW 40 240 270 295 320 L=S !6D 65 585 650 715 780 L=SW 45 405 450 495 540 L=SW 70 630 700 770 840 L=SW Limited Access highways shall use a 1000' merging to r regardless of the posted s ed. Shiftin Tapers sea Table 6H-Z' Shoulder Taper ='h L Minimum Channelizin Device Spacing Location Speed Limit m h Location Speed Limit (mph) Location Spacing Speed Limit September 2019 Page 011.41 Outside Lane Closure Operation on a Four -Lane Roadway (Figure TTC-16.2) Oa i 0 PTRS SPACING O (CENTER TO CENTER) POSTEDISTATUTORY SPEED LIMIT S40 MPH 10 FEET 41 - 55 MPH 15 FEET > 55 MPH 20 FEET SHADOW VEHICLE REQUIRED O (TMA REQUIREMENT SEE NOTE 10) rj ILLUMINATED FLASHING (AMBER CAUTION MODE SUPPLEMENTAL TYPE B OR C PTRS OPTIONAL SEE NOTE 14 SEE NOTE 2- O 0 o ILLUMINATED FLASHING old ARROW BOARD _ TYPE C SEE SEE NOTES 4 8 8 l NOTE 2 I ti i I W4-2R SEE _ ' NOTE2 KEEP LANE ENDS w9-2L R4-V7L j� MERGE LEFT `CPT RIGHT W9-3R SEE LANE NOTE 2 CLOSED R16Nf AHEAD LAME .y,r CLOSED M SEE PTRS OPTIONAL NOTE 2 SEE NOTE 13 RII RUMBLE STRIPS i STRIPS W20-V28R le REQUIRED y SEE WITH PTRS W20-V28L NOTE 2 REOUIRED WITH PTRS ROM RUMBLE W20-V26 STRIPS, - if STRIPS REQUIRED AHEAD WITH PTRS SEE NOTE 2 ROAD 1 1 ROAD WORK - MIT._ WORK W20-1 AHEAD AHEAD PCMS- SEE NOTE 3 U r m w 5 ro 0 U° O Z Z Co o(O �Y� 2 J H 00)) Maw O Q T �tIr J = �1 OU ¢� m �V dZ =w Q ow w 0 0 W OQ �a QZ v0 Z� oC EA > o h.j o Fit w Ij n a_ > No v F--d a W N w Q z J > O va w a J _ In O aZw Z w �a m= rn O Z 0 L W N O� z z 00 Z Z z z 00 U U � v 0 0 Z ti ,i ��o�D `r��2 U 9Jigart4A�'o1�,�G J Q a Z CJ Q� 0> < tll a 0- CE a 0 �zLL2 O m z O a o �O LL O Q 2 !R Z LL L1J X Z tr O `O V DATE: 10-25-2019 SCALE: NA JOB: 19.0125 SDP-2019-00062 SHEET: 9 OF 13 PLANTING REQUIREMENTS STREET TREE REQUIREMENTS 1 LARGE TREE PER 40' STREET FRONTAGE (ENTRANCE CORRIDOR -HYDRAULIC) 248.5 LF OF FRONTAGE TREES REQUIRED = (248.5/40)= 6.2 TREES REQUIRED TREES PROVIDED = 6 1 MEDIUM TREE PER 40' STREET FRONTAGE (GEORGETOWN) 79.6 LF OF FRONTAGE TREES REQUIRED = (76.6/40)= 2 TREES REQUIRED TREES PROVIDED = 2 TREE CANOPY CALCULATIONS TOTAL SITE AREA = 1.05 AC (45,747 SF) PRESERVATION AREA = 0.27 AC (11,648 SF) NET SITE AREA = 0.78 AC (34,099 SF) 10% TREE CANOPY REQUIRED = 3,410 SF TREE CANOPY PROVIDED = 7,979 SF (23.4%) LANDSCAPED PARKING AREA REQUIRED 5%/1 TREE PER 10 PARKING SPACES AREA REQUIRED = 13,304 SF PARKING AREA * 5% = 665.2 SF AREA PROVIDED = 1,164 SF (8.7%) TREES REQUIRED = 35 SURFACE PARKING SPACES / 10= 3.5 TREES TREES PROVIDED = 4 TREES (2-KP, 1-LN AND 1-AB) CONSERVATION AREA PLANTINGS 2:1 REPLANTING RATIO FOR EVERY TREE OVER 12" DBH TREES REQUIRES = 3 TREES REMOVED * 2 = 6 TREES TREES PROVIDED = 6 TREES PLANT SCHEDULE TREET TREE NOTES sun DETAILS NOTES & MINIMUM STANDARDS 1. TREES SHOWN HEREON WERE SELECTED FROM ALBEMARLE COUNTY'S RECOMMENDED PLANT LIST. SUBSTITUTIONS MUST BE APPROVED BY THE ALBEMARLE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT AND THE LANDSCAPE ARCHITECT. 2. IF A SUBSTITUTION BECOMES NECESSARY, FEMALE GINGKO BILOBA WILL NOT BE USED. 3. PLANT LIST TOTALS ARE FOR CONVENIENCE ONLY AND SHALL BE VERIFIED PRIOR TO BIDDING. 4. TREES SHALL BE 2.5" MINIMUM CALIPER MEASURED 6" ABOVE GROUND LEVEL WHEN PLANTED. 5. TIMING OF INSTALLATION: ALL LANDSCAPING SHALL BE INSTALLED BY THE FIRST PLANTING SEASON FOLLOWING THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY WITHIN THE DEVELOPMENT, OR PHASE THEREOF. 6. ALL TREES TO BE PLANTED SHALL MEET THE SPECIFICATION OF THE AMERICAN ASSOCIATION OF NURSERYMEN. PLANTING SHALL BE DONE IN ACCORDANCE WITH EITHER THE STANDARDIZED LANDSCAPE SPECIFICATIONS JOINTLY ADOPTED BY THE VIRGINIA NURSERYMEN'S ASSOCIATION, THE VIRGINIA SOCIETY OF LANDSCAPE DESIGNERS OR THE VIRGINIA CHAPTER OF THE AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS, OR THE ROAD AND BRIDGE SPECIFICATIONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. 7. CONTRACTOR SHALL ASCERTAIN LOCATION OF ALL UTILITIES PRIOR TO EXCAVATION. PRIOR TO COMMENCING ANY WORK, CONTACT "MISS UTILITY" AT 1-800-552-7001. 8. ALL PLANT MATERIAL TO BE GUARANTEED DURING INSTALLATION AND UNTIL FINAL PROJECT ACCEPTANCE. ANY PLANT MATERIAL WHICH DIES, IS DAMAGED OR DISEASED, OR IS UNHEALTHY AND IN UNSIGHTLY CONDITION, OR OTHER CAUSES DUE TO CONTRACTOR'S NEGLIGENCE SHALL BE REPLACED IMMEDIATELY AT THE CONTRACTOR'S EXPENSE. 9. MAINTAINING AND REPLACING STREET TREES: ALL STREET TREES SHALL BE MAINTAINED IN A HEALTHY CONDITION BY THE OWNER AND REPLACED WHEN NECESSARY. REPLACEMENT MATERIAL SHALL COMPLY WITH THE APPROVED PLAN. 10. ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT MATURE HEIGHT. THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. KEY QNTY. BOTANICAL NAME COMMON NAME SIZE NOTE 10-YEAR TREE COVERAGE AREA (SF) TOTAL (SF) Canopy Tree AB 5 Acerrubrum "Brandywine" BRANDYWINE RED MAPLE 3.5" Cal B&B 452 2260 KP 2 Koelreuteria paniculata GOLDENRAIN TREE 2.5" Cal. B&B 380 760 LS 1 Liquidambarstyraciflua SWEETGUM 2.5" Cal. B&B 288 288 LT 1 Lirodendrontulipifera TULIP POPLAR 2.5" Cal. B&B 430 430 QC 4 Quercus coccinea SCARLET OAK 2.5" Cal. B&B 419 1676 Understory Tree SB 1 5 lAmelanchierx grandiflora "Autumn Brilliance" AUTUMN BRILLIANCE SERVICEBERRY 6-T Ht. B&B 130 650 CC 1 2 ICercis canadensis "Forest Pansy" FOREST PANSY REDBUD 6-T Ht. B&B 124 248 LN 1 2 Lagerstroemia x 'Natchez' NATCHEZ CREPE MYRTLE 7-8'Ht. B&B 88 176 Evergreen Tree IC 1 6 Illex x'Conty' I LIBERTY HOLLY 3-4' Ht. B&B 10 60 IP 9 Ilex x "Cono" PATRIOT RED HOLLY 7-8' Ht. B&B 44 396 TO 11 Thuja occidentalis "Emerald Green" EMERALD GREEN ARBORVITA 3-4' Ht. B&B 8 88 Shrub AG 18 lAbeliaxgrandiflora 'Little Richard' LITTLE RICHARD ABELIA 24" Ht. Cont. BG 24 Buxus x "Glencoe" CHICAGOLAN D GREEN BOXWOOD 24" Ht. Cont. HQ 14 Hydrangea quercifolia "Ruby Slippers" RUBY SLIPPERS OAKLEAF HYDRANGEA 24" Ht. Cont. JC 14 Juniperus chinensis "Nick's Compact" N ICK'S COMPACT J UN I PER 24" Ht. Cont. VD 13 Viburnum dentatum "Christom" BLUE MUFFIN ARROWWOOD VIBURNUM 24" Ht. Cont. 31 403 VP 17 Viburnum x pragense PRAUGUE VIBURNUM 4-5'Ht. B&B 32 544 Grasses SS 1 129 Schizachyrium scoparium 'Carousel' ICAROUSEL LITTLE BLUESTEM 1Gal. 24"O.C. TOTAL 7,979 County of Albemarle Conservation Plan Checklist -To be placed on Landscape Plans (Handbook pp III-284-111-297 for complete specifications) 1. The following items shall be shown on the plan: ❑ Trues to be saved; ❑ Limits of clearing (outside dripline of trees to be saved); ❑ Location and type of protective fencing; ❑ Grade changes requiring tree wells or walls; ❑ Proposed marching ortunneling beyond the limits of clearing. Z. Marldaea: ❑ All trees to be saved shall be marked with print or ribbon at a height clearly visible to equipment operators. ❑ No grading shall begin until the tree marking has been inspected and approved by a County Inspector. 3. Pre -Construction Conference: ❑ Tree preservation and protection measures shall be reviewed with the contracmr on site. 4. Eauloment Oueration and Storaue: ❑ Heavy equipment, vehicular traffic and storage of construction mmerials including soil shall not be permitted within the dripline, of trees to be saved. S. Soh Erosion and Stormwater Detention Devices: ❑ Such devices shall not adversely affect trees to be saved 6. ❑ Fires arenot permitted within 100 feet of the dripline of trees to be saved. 7. Toxic Materials: ❑ Toxic materials shall not be stored within 100 feet ofthe dripline of trees to be saved. S. Protective Factor. ❑ Trees to be retained within 40 feet of proposed building or grading activity shall be protected by fencing. ❑ Fencing shell be in place and shall be inspected and approved by a County Inspector prior to grading or construction. 9. Tree Wells: ❑ When the ground level must be raised within the dripline of a tree to be saved, a tree well shall be provided and a construction detail submitted for approval. 10. Tree Walla: ❑ When the ground level must be lowered within the dripline once to be saved, a tree wall shall be provided; and a construction detail submitted for approval. 11. Trenching a ad Tunneling: ❑ When trenching is required within the limits of clearing it shall be done as faraway from the trunks of trees as possible. Tunneling under a large tree shall be considered as an alternative when it is anticipated that necessary trenching will destroy feeder mots. 12. Cleanup: ❑ Protective fencing shall be the last items removed during the fmnl cleanup. 13. Damaged Tres: ❑ Damaged trees shall be treated immediately by pruning, ferdliudion or othermethods remmmaded by a tree specialist NOTE: IT IS THE DEVELOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION REQUIREMENTS. E�e..f (DATE) . 5/1/06 Page 1 of 1 TREES TO BE REMOVED: - TREES 12" OR GREATER TO BE REMOVED IN CONSERVATION EASEMENT ARE: ♦" `� + 1. 18" POPLAR 2. 20" POPLAR 3. 18" OAK #0 o"oA I 1 Ji I DECIDUOUS TREE PLANTING DETAIL GALVANIZED - GUY WIRE/ / 2"X2" HARDWOOD STAKES �1\12U GALVANIZED I /RUBBER HOSE GUY WIRE I n 2"X2" HARDWOOD I 24"PINE QC "MPL I I TMP 60E-1 DYNAMIC INVESTMEN CAPITAL ENTERPR/), ZONED: C-UIL1 USE: OFFICE BG 44C - KIP KIP I_ A II FH I I � I I- 11 � 2 1 j Pop 11 1 t 1 li �' �t; •,, I, I i 1 rl I 24"PINE >I I 1 !F I I 01 I i it I I 10"POP 5"PIN j h rill ' 1 1 I 1 1� ' ) � � ' 'i1 t' 1 1 wE 12"oAK . 18"++L 10"POP Z1 11 11 I „ 1 i LS 1 1215"POP 1 i �_ s 4"PINE I _ 1 1 PRESmvmi iN 10"PoP AREA i 1 o"MP 5'c Rv QC I ; t 11 II II I + 22 I j �' i1Y 1 ' 18"MPL / D2. 1i F9 t 11 I 11 1 II 24"CHRY + ') �� ;a � an 8 + + "MPL ' 10"BCH I 12"PP + i18"MPL + 10"M jL 10" OP L 111 II 1 20"POP + \w I NEW 20' A II EASEMENT � SHREDDED HARDWOOD ,� 36" OAKX2 �_/ REMOVE BURLAP FROM �♦ . MULCH MIN. 3" DEPTH TOP 1/3 OF BALL w 10"MPL " ♦ ♦ w \ \ \�\R\j�\\\\XEARTH BERM ♦♦ ♦ TO 'AREE ROUND T 1 \ ♦♦ TWICE ./'' BALL DIAMETER TMP 60-76B MICH MELINDA ♦♦ APR& KEL ZONED: RA ♦- 20 0 20 40 60 USE: RESIDENTIAL SCALE: 1 "=20' li��♦ Sn♦ LN 1 / 0 X. e i e VD 7 VD 7 e M h I M6 - N ffia 111 14 B� i 9;_ 3 t LEGEND: GIS CRITICAL SLOPES >25% PRESERVATION AREA CONSERVATION AREA - LANDSCAPING PLANTS AND TREES ADJACENT TO THE SIGHT DISTANCE TRIANGLE WILL NEED TO BE MAINTAINED IN AREA BETWEEN 2 AND 7 FEET ABOVE THE GROUND AS A CLEAR ZONE TO PRESERVE SIGHT LINES AND ACCOMMODATE PEDESTRIANS I I 1 1 1 II 1 I 1 'I 1 I 'I 1 BG 1 1 6 1 1 uI i I :.: '< 1��o BG i 1 ..•.:1� SS 1 23 1 1 +'AB K PROP. 1.5" DOMESTIC CONNECTION WITH 1.5" METER & BOX SS 45 SS AB 61 20' RWSA EASEMENT 1 r o zU w C0 C0o U -m OO(o Z Z co �Y> 2 rn J a0 2�Ld 0 OIr U ¢CJw 1. W pm ¢o OD °a �Q JZ vU ZO �> o w o w F+i Z Oj o � W N N w a Z > �V o U wl J a J _ C) C n O aZw 00 Wm U Q rn U Z 0 d N zw O� z z 22 0 0 z z 0 0 w CD CD in a 0 0 Z N ��Pt,TH OF Dr�� / 2 Jimmy L. Taggaft Lie. No. 22841 4 'Po�, 08/03/2020 �w SSSIONAL Sl' U D a a< Q E+ Z �Cf z� 0 j Q Q Ld t'fJ CE W LL = Q J CID W W o_ a o � Z LL z >>0W QOQLLa I j a IZ-i Q Z 0 ir U Q O ( V DATE: 10-25-2019 SCALE: 1 1 ":20' JOB: 1 19.0125 SDP-2019-00062 10 SHEET: OF13 TYPE A sa VSS-1 SITE LIGHTING 7RANCTION lde housingr optimum thermal management _ • Low depreciation rate • Optical system designed for: - Parking Lots - Commercial Applications --._._- CONSTRUCTION • Die Formed heavy duty Aluminum • Corrosion resistant external hardware • One-piece silicone gasket ensures IP-65 seal for electronics compartment • Two-piece silicone Micro Optic system ensures IP-67 level seal around each PCB FINISH 3.5 mils electrostatic powder coat. • NLS'standard high -quality finishes prevent corrosion LISTINGS protects against extreme environmental conditions Certified to UL 1598 • CSAC22.2No.250.0 WARRANTY . DesignLights Consortium°i(DLC) go Five-year limited warranty for drivers and LEDs. . Design Lights Consortium Premium"(Di • IP65/IP67 Rated R•Ne �co n Sc �L us �i 1 �. LISTED d r LED WATTAGE CHART Me m0liaays - - neMllrlamW - - no retaliation, 71. IGhe 13aw IM5 m H%w laet, 2osw Project Name GEORGETOWN HYDRAULIC "' A VSS-1 T4 48L 1 40K UNV DP6 BRZ HSS Value series Type 2 32 (32L) 700 300DK 12U-i Duec[ P. P bronze End so ken (U) Squz7e1 (y2) 48(gy M (3010 (UNV) ypyP DISO (Bill Marnemam Finish(1141 toss-1) 6" (DP6 Surge Pmtecte, Ilex) 64(64L) 1050 : 4000K 340-4tl0 ) White Name 7-Pm Rancor;:. (PET) Type 3 : (1) (40K) : (HV) Dq0 T90 T120 no tltll/i) Photocell (PC) (Till 10-(DP70) Silver •la"w"'ulV°ir'"-. ` ' 5000K ror,PowdfN.. corn« gm arewm (�) Photocell+ Recept... �c(POR) -sae„e.rma• rn, am c,�,r Type 4 (SOIh motion Sens. MS) : ECP z11 with Unrest mnsn, (i4) Knuckle Mount (Kith (8LK� For e'+Below Map-0) Trunlon Mount Far91.20' BP.20 ) Grap�.kirte Types Fa21'1o40'� OP•40) Wall Mount(Wu) (Gr^I •Awlgnaena.WFSP-]I r are mreg""s CM) •MGWea 6"Boll On Arm tl4e fiAUaa Grey Tenors Arm (TA) (0RY) Oulek Mount Brarkel(0Mo) edema 3 (MOMS) Quick Mourn Brackeion CIce) • Im4mal bhaowave Motions • 30" ei A Son (INNS) eats, Beam (CS) RlHate Optic Right (ROIq OR) (/13) Battle Dpnc Left (ROL) - Bound Pole Adaptor YA' Pole (RPM) Round Pole Adaptor V 6' Pole (RPM) House Side Shields OMI •NSrn. Wheask wan N3 Noun to'mnrs A Rcmolwe House Sde Eh,eb (AHD) Acrylic Optics ("I TYPE D VSS-1 SITE LIGHTING FORM AND FUNCTION • Sleek, low profile housing . Engineered for optimum thermal management • Low depreciation rate -_ • Optical system designed for: - Parking Lots - Commercial Applicationsw�F2•-a" CONSTRUCTION • Die Formed heavy duty Aluminum • Corrosion resistant extemal hardware • One-piece silicone gasket ensures IP-65 seal for electronics compartment • Two-piece silicone Micro Optic system ensures IP-67 level seal around each PCB FINISH 3.5 mils electrostatic powder coat. • NLS'standard high -quality finishes prevent corrosion LISTINGS protects against extreme environmental conditions .Certified to UL 1598 • CSAC22.2No.250.0 WARRANTY • DesignLights Consortiuma(DLC) Five-year limited warranty for drivers and LEDs. . Design Lights Consortium Premium" (DLCP) • IP65/IP67 Rated Rave a••ii- ■C@us ® � LED WATTAGE CHART Me moomp. NO MIWnp• - - ND intense, 71w IN. 130. Io50 IG6w latest 2061 Project Name: GEORGETOWN HYDRAULIC type: D VSS-1 T4 32L 7 40K UNV DP6 BRZ HSS Value Sens Type 32(32L) 7011 n000K 120-1. Direct Pale Bronze Bird Spkes(BS) Squares (y2) 48(py (7) (30K) (UNV) $Ipglp_n1Np (8112) Marne Grace Fnish(MGF) (VSS-I) 64 641 ( ) 1050 4000K 6"(DP6) 340-480 White surge Protects (le(P edema 7-Ph Receptacle (PDT) Type 3 (1) (40K) : (IRh Dan TOO T120 0n (ltll/n Photocell (Po) (T3) 10.(DP70) Silver •Louversal Voflope 7M277 5000K "For,Aseve, z :: vow gm lre�rn• ( ) -sae,¢.rm9e lr am c.�,r Pho[ocelN Neceptacle (PCR) Type 4 (6010 Marian Sensor (DID) : (T4) Knuckle Mount (KM) (8�� FSP.III with Motion run.,., , Trunion Mount(TM) - Grapk�_ite For O'+Below(la p-B) Far 9'fo 20'(FBP-20) ' Types Wall Mount (With (0PN1 Fw2i'H4O'(FW-40) •AM1NonSamnaratlfifil aHvil,,tl to (T6) •wGIAes 6"Bolt On Arm Grey aefiApn Tenors Arm (TA) (DRY) Quick Mount Bracket (OMB) Nectar 3 Pm.1 Mi Oka,enive MountBracketOMM • 30" Custom, So ., • In lemal Mrcrowawe Motion sen:o, (INM6) ealraW Beam (CS) Rotale Optic Right (NOR) (113) Rotate Optic Left (ROL) - Round Pole Adaptor YA' Pole (APA4) Round Pole Adaptor 5' 6' PUic (RPA5) House Side Shields 0Ms1 •R3snetWka nap B3 NtlIA ao-ma=s Aut.nolive HDU6 sideawed(MIS) Acrylic pants (AD) OPTICAL CONFIGURATIONS Rotatable Optics (FOR) Rotated Right, (ROL) Rotated Left options available. Optics field and factory rotatable MT MIMBER •DLC 9 Standard {'= Premium ,M DPX ARM LENGTH VSS-1132L VSS-1/48L VSS-1/64L wl am s BI-UO41 5e A118 � NS8 1165112 R 7e IlM1lHFGlfell Ii]1xwotfewi ao 4615UFGzTear 72 Daaz1oaa,% J-G�l 2s 6466xF62was m MailUB•G2idea n ofxFG2gG2-In -0 6760FG2 L232 72 NOT $7 sMq-02 118. Ix 9516 61 Bt G2 1. as 01 a5 atLNw2 9TT i) 152 5r BOigG2 w5n . use 61 BtLO•G2 1. a9 WIT 65 B1i (32 14Tm 12 11695 M1 B1.U�G2 I SSxO 1x IzSn 61 e1�ro-Gs 1Mm m r 65 B1.G1 BOB I TO IIMMloscl N9G T4 IraW 1l i BOG In I-IDLCI BOB L70/L90 DATA Term,vss-I 25'C L70 483 coo >60 000 CO sD°c n2o� aD lo� EPA 0' p EPA SOL190 D90 D80 T90 0'-open l rG'-ewxlo s ns0 1.52 .0 L43 2.34 0Px AAM LENmH sGL� 090� 01801-8 T90 vsSl 6' 10' 6' 1W MOUNTING OPTIONS �>r To - DIRECT POLE (DP) standard mounting arm is extruded alumloum in lengths of 6', And 10' ^Arm lengths may vary depending on Configuration WALLMOUNT (WM) Cast Aluminum Plate for direct wall mount. 6' extruded aluminum a" mounts directly to a cast wall mount box, NLS701 Kingshil Place, Carson, CA 90746 alslighting.eom LIGHTING Cal Us Today 1310) 341.2037 Rotatable Optics (FOR) Rotated Right, (ROL) Rotated Left options available. Optics held and factory rotatable 0:ll:.'i -DLC A Standard P Premium DPX ARM LENGTH am AIM Miss Lane &A 5112 s3M i2 M aQ 4a11 51 or 6011FG1 BO41G.dt s6e4 eE 4615 65 ewucz Taal 72 W2 57 fKauli xO% 16 fal 61 BODUG2 was so 6aB0 0 BOUB.G2 riw n Slue 57 BOlOG2 Isdt . 6314 61 RO4gG2 x3N a0 6760 65 60.iii 11293 72 NOT $7 RI.41G02 118.1 Is 9516 61 61 @G2 ta•m as 0, 65 8s110Ga 91?T i) 152 5r BDF til mx Te 829E 61 Bwa•G2 I rem a0 OHO 65 81i1.G2 Him a nem s B1.r16G2 *W le 125M 61 B11A G3 m istraS 63 sf rs•G8 N3G ITS ILWWIDLCI sin T4 IIaWslD l BUG I TO Ia spied BUG L70/L90 DATA VSS 25'C LT 483000 L .60000 so°c n2o� aD� EPA 0' r EPA SGL "0 DIOD TSO 1120 D a• -open l rO'-ewxlo vsS1 I n90 1.52 B 4 DPX ARN LENmH SOLI 090% DIB01-B T90 vsSl r f0' 6' 1W MOUNTING OPTIONS -r- TV DIRECT POLE (DP) Standard mounting arm Is extruded aluminum in lengths of 6, And 10' -Arm lengths may vary depending on Configuration WALLMOUNT (WM) Cast Aluminum Plate for direct wall mount. 6' extruded aluminum arm mounts directly to a cast wall mount box, NLS701 Kingshil Place, Carson, CA 90746 rdslightin9.cern LIGHTING Cal Us Today 1310) 341.2037 SQUARE STRAIGHT STEEL POLE POLES BASES POLE Shall be Straight Steel Grade B Extrusion with yield of 46,000 PSI. Conforms to ASTM A500 Standards. Poles have ground lug welded inside hand -hole opposite side of the pole extrusion. Pole Extrusion is conjoined to Anchor Base by welding internal to pole shaft and external to pole shaft. Hand Hole reinforcement is Constructed of 3"x 5" rectangular steel tubing which is welded to pole shaft for added strength. ANCHOR BASE Manufactured from A36 Steel rated at 36,000 PSi, conforms the ASTM -A36 standards. Base Plate vary in size from 1" thick for poles 21 feet and over, 3/4" thick for poles 10 to 20 feet COATING All poles have minimum 3mm powder coat finish. All poles are sandblasted prior to powder coat application. ANCHORAGE All anchor bolts are fully hot dipped galvanized and come with two galvanized nuts and washers per bolt. BASE COVER, HAND HOLE COVER AND POLE CAP All poles come with removable polymer pole cap installed. All poles caps are black finish. All base covers are made of aluminum and powder coated to match the pole. The hand hole covers are provided with internal bridge support and also powder coated to match pole finish. Ai& 0 ect Name'TypeEORGETOWN HYDRAULIC A,D POLE P SSP 15 4S 7G 9BC SGL BRZ 3430 •e 4 Square w Dof 4- Square 120 in 'S Single P Z, SVaight o2) (45) (110) 6 10snr, (SOL) (BRZ) (3430) tan) Steel Polr : Bolt circle .+, Feame.on Oke, 114) White -, (PRo19 5' Square : 180 m (9BC) : Double twtm (16) (68) : (TG) : (D-20) (136) Galvanized Oq ._ .: (D-100) : Silver - (am 6' Square (20) (8VR) And colro5gn (22'-351 Triple (Airy I72) 11IT-14- j R-f0) Green - r74) Boll Circle (GAN) A•m 1251 (12BL) Quad Hunter Green : =sea""na roll) - I (OD) rBo„m lib)._... : (NON) (mill ax R rmi m 128) (39') Black n P T(141n) 130) 15 m (BLK) a+s �mml Bolt Circle 29 ,.-,Train) pp tti mrN) - - Grey -. (CRY) Custom (CS) 140 TYPE E MAXiLUME LIUCUITECTURAL LI0M r1Y6 By ONE L ahhna 40 I&-.qda 11 404040"am 40�. s CL- CLd 11 0Q-9r(I N0-MD wf AFw1l MB-wil CL-Bx sell A SOOL to 4000L Haight= !i A WOOL to 8000E Height = 9- B: Trim ApenvH= b3/6' QCuF0ut=6F13/lV D. Trim Winds Ua=7.3/r E WMIh = I V F Length = ZO33' NOM aLUMENS DEIIW:REOLNAms WAWIMSE 8000 7772 Sow 6000 606 72W 40m 4649 46 W 3000 3374 36W 2000 n52 22W 1500 17AS 20W 12M 1.22 16W Bad INS 12W Based on 400190+CR1 with semFspeculor chrome reflector. Actual wattage may vary+/-5% saw Land "power Oisfribwon Curve -. HH6-LED 61/ 6" Architectural High Lumen LED Downlight FEATURES A highly sustainable and ultra -efficient architectural LED downlight that provides even. glare -free illumination. Available in a range of finishes. distributions, and lumen packages, it is ideally suited for use in corporate office space, hospitality, healthcare, commercial, academic, churches and retail. OPTICS AND REFLECTOR The reflector has a 45- visual cutoff, and is shipped standard with a Solite lens in a smooth frosted finish. Spun from 0,05" thick aluminum, with a I -step anodized finish, and available in different colors or custom RAL finishes. Reflector flange options include self - flanged and white painted flange. Various distribution options are available, and all optics are field changeable. 900.1200. 1600. 20DO, 3000. 4000, 6DDO, 8000 room Timm packagesaraissNel K 3D(, 35K 4pL 50(, TIF1aNe BOB WIOe. oBnsto Warm, HG0K. 3 ® 96+Slandard. 9B+OMlmal . . - . 2 step MecAddra 9p3se . • : • WD Wide DB01Ustlml, MD Biledum Db116utlml and ND INalmw Darrib n1 Dwatll0m. Wall Wash. Double Wall Wash. WM Ltxatlon HCILem). WT lyenihr Channel), SfQ 0.ow Ini,L•scem Sati11 • • • • Hem). kVT (WheaU. W M'Nkel. MB ff." p Plamlq. fid WR Ent Safi I). ®SRZ • , . (Los Hai SHZ IION kllkscalt Satin Haml. B(IBbr10 OK cN 1antlad DN11DI. WTI(. LUT2W. ®LUTFT ELD01 .1. ELD B, LUf2W. ELD014,. BD00fALt, t3.DOMLL1. gMTR DIMT 1001-Up N 1BOX Dutrad (Bodine BST110 ) 2OW-Lip N 2000. Outplx ( Sadne BSL201 ® L70 at 102,000 Hours In Accordance with ES LM7406, LM80 and TM i0 TM-21 .,ndlep vea Distribution cue• 4OY �M m. yaN• W" AMWG 0 ehW www.luseelite.corrl F•*nNo D POLE 121w 12' Base Bolt Circle Aow 9.0 i1 9" Base Eck Circle 092 POLE EPA DATA Maximum EPA (R) Allowable POLE HEIGHT POLE dA SIZE BASE PLATE BOLT CIRCLE BOLTS BOLTS 80 Mph 90 Mph 100 Mph 10' 4' SQ .120 9" SOL x %, 9". S' x 30' 26.8 18.7 15.5 12' 4' SO 120 9" Sq. x'/•' 9 •^" %'s 30- 20.5 15.5 9.7 14' 4"SQ .120 9' .xW 9-v Wx30 16.5 11A 9.1 15' 4' SQ .180 T Sq.. % 9 v.n" it' x 30" 18.2 12.2 t 0A 16, 4" SQ .120 9' Sq. x %, 9 vw M." x 30' 13.5 2.8 8.6 17-X' 4' SQ .120 9" Sq. x %- 9 1'+" A' x so- 12.4 9.0 7.2 18' 41SO .120 9"Sq.x'/.' 91W Y.'x 30' 9.8 7.2 5.4 20' 4' SQ .120 9" Sq, x'G' 9 >"+" W x 30' 8.2 5.5 4.0 20' 4' SO .180 9" Sq. x $" 9 vW W x 30' 14.5 10.0 7.6 20' T SQ .120 12' Sq. x 1' 12 ?: 1'x 36" 16.2 11.3 7.9 20' 5' SO .180 12' SO.. V 12 "A' IN 36" 26.2 21.2 15.4 22, 4' SQ .120 12" SR. x P 12 W' V. 36' 6.3 3.7 1.8 22' 4' SO .180 IT Sq. is 1' 12 W' 1'x 36' 11A 7.9 5.3 22' 5" SQ .120 12' Sq. x V 12 W" IN 36" 12.5 8.3 5A 27 S' SQ .180 IT S x V 12 W' 1'. W 21.1 152 10.9 24' 4' SO .120 12'Sq.s 1' 12 W" 1's 36" 5.3 2.7 1.5 24' 4" SQ .180 12' Sq. x V 12 W" IN 36' 10.8 6.8 4.2 24' 5' SQ .120 12" Sq. x 1' 12 la 1'x 36' 5.3 2.7 1.5 24' S" SO .180 12"Sq. x V 12 W' 1'x 3W 19.8 13.7 9.1 25' 4" SO .180 17 Sq. x 1' 12 W" I'x 3T 10.9 7A 5.2 25' 5' SO .120 12" S0. x 1' 121E 1'x 36" 10.2 6.6 L6 26' 6' SO .180 12" % 1' 12 +u' 1'x 38" 18.9 132 9.6 26' 4" SQ .120 IT Sq. x 1' 12 ia' 1'x 36' 4.7 2.5 1.2 28' 4' SO .180 12" S a.. 1' 12 W- 1'x 38" 10.7 7.1 4.9 26' 5" SQ .120 12' Sq. x 1' 12', Vir 36' 9.8 6.3 1.3 26' 5" SQ .180 12' Sq. x 1' 12 W" Tax 36" 18.5 12.9 9.4 28' 4" SQ .180 12" Sq. x 1' 121E 1'x 36' 6.0 2.2 1.6 28' S-SO .120 ITSq.x 1' 12 W' IN 36" 5.8 3.2 1.5 28' 5' SQ .180 12' Sq. x 1' 12 +� 1's 36" 12.2 7.8 4.6 28' 6' SO .180 12" Sq. x 1' 12 Yi IN 36" 21.7 14.6 9.8 30' 5" SQ .120 12" Sq. s 1' t2 ?. 1'. 36' 5.2 2.3 - 30' 5" so .180 12'Sq.xV 12W IN 36' 11.6 6.9 4.1 30' 6' SQ .180 12' Sq, x 1' 12 W' Vx 36" 18.8 12.7 8.3 32' 5' SQ .180 12' Sq. x 1' 12 Yi 1'x 36' 10.1 4.9 2.6 32' 6'Sa .180 IT Sq. xV 12 A'i Vx 36' 16.6 8.4 5.2 35, 5' SQ .180 12' Sq. x 1' 12 W 1'x 36' 8.8 2A 1.9 35' 6' SO .180 12' Sq. x 1' 12 W' Vx 36" 12.2 7.1 3.9 39' S" SO .180 12' Sq. x 1' 12 W 1"x 36' 3.1 39' 6' So .180 12' Sq. x 1' 12 W' 1"x 36" 7.3 3.0 NLS701 Kingshil Place, Carson, CA 90746 LIGHTING CA UsToday (310)141.2037 dslighting.com MAXIOLUME rARCUl160TUBAL LIOUTINOT By Elite Liandna THERMAL MANAGEMENT SYSTEM Passive coolingDiecast Aluminum Heat Sin LED light engine and k g g driver are replaceable, upgradeable, and can be accessed from below the ceiling. The consistency in the quality of light is delivered with precision performance by the use of a unique locking mechanism that aligns the reflector with the light engine. MOUNTING FRAME & BRACKETS The downright mounting frame is a fabricated assembly constructed of 16-gauge steel. with C-channel mounting brackets. included. The versatility of the mounting brackets allow for an adjustability, of up to 28" horizontally, and 2-3/4" vertically, locking into place. With the added die -formed construction of the mounting frame, it provides maximum heat dissipation and rust protection. DRIVER ELECTRICAL INFORMATION The LED driver is rated for 50 to 60Hz at 120V1277V, also available in 347V input, produces less than 20%THD, has a power factor between 90% and 100%, and is thermally protected for additional safety. Junction box and Driver can be accessed from below the ceiling and above the ceding. Junction Box is Listed for through branch circuit wiring. DIMMING & DRIVER INFORMATION DIM10 - D•1 OV dimming on either MVOLT 120. 277 or 347V. Dimmable down to 1 % of initial lumens. standard. DIMTR -Triac & Electronic low voltage dimming. Available in 120V, and up to 3000 lumens only. LUT2W - Lutron LTEA2W HLLume 1%. 2-wire LED Driver Forward Phase Control, 1 % dimming in 120V only. Available on all luminaires up to 3000 lumens. LUTH-Lutron LDEI Hi-Lume Eco System. 1 %dimming with Soft in Fade to Black dimming technology. Available on al luminaires up to 3000 lumens. LUTFS - Lofton PEQO Hi-Lume Premier Eco System. 0.1 % dimming with Soft in Fade to Black dimming technology. Available on all luminaires up to 1500lumens. ELDO70.1 - ENdoLED SoloDrlve 0.1 OV. Dimming down to 0.1%. Available on all luminaires up to 100 watts. DAU- DAL] DT6, DT8 dimming down to 1 %. Available on all luminaires up to 100 watts. ELDODMX - EJdoLED PowerDrive dimming down to 0.1 %. Available on all luminaires up to 100 watts. Please see EldoLED webshe for wiring diagrams and a list of compatible DMX and DALI control systems. HH6-LED G 6" Architectural High Lumen LED Downlight LED DYNAMIC PLATFORM OPTIONS Tunable White with Smart White Technology utilizing the Lumenetix Platform allows you to colortune the luminaire via various controls. Create the perfect environment for the desired use of the space, while maintaining a CRI of 9o+ across the tunable range of 8000 to 1650K. (Click here for more details) x Dims to Warm with Smart Dimming Technology. At 100% full brightness the luminaire is at 3000K When dimmed to I %, the light transitions to 1 BOOK creating a warm ambiance within the space. (Click here for more details) .at► RGB+White with Smart Hue Technology provides full color 'i mixing of ROB and white colors. Utilizing the Lumenetix Platform allows you to choose from unlimited RGB color options, via various controls. Ideal for Circadian Rhythm applications or to create the perfect human centric environment. (Click here for more details) WARRANTY Fivei warranty for parts and components. (Labor not included) LISTINGS c-ULy s-Listed for Wet Location if used with HH6.6501 Trim. c-ULyus -Listed for Feed Through Wiring. U.S Patent No. - D685,118S CP-City of Chicago environmental air (CCEA) marking for plenum applications. Energy Star and California Title 24 compliant Lsai•. HH E0-2000L-GNIO•MeOLT-MD401(-90-HH6.6: L-WK IIIIfr 0 J 900E J i 10 J 120 J 21K J EEG-LFO.toil U WI6fi501 J 120OL Li DR"M J 277 J 30K J [MG-LED-20W J H O-6507 J 1500L J LUTH J MVOLT J 35K J INFG•EMG-LED-1 OW J 2000E U WTZW J 347 J 40K J IMG-EMG-LED-20W Hanged Well Wa9Y ,.. 11 ' - U BrtiE577 J 3000L U LUTFTB J 50K _.: nmyel Doubts War Wu1, J4M yELDOl(nl -. '.. . J GOOOL J ELOODALF.1 a J 8000L U ELDOOMx-.1 J WO J 90+ J CP u,us=+nan, J MD J 98+ J ND J HH6-TL-6501 ,bit.;. --:,: 111 m16-TLHi507 IA 1• r J INTG ware nl Trio« R,m a,e+,nwe,mnubbrnollm- 1 s" DMt05%Is' aeaibde only f. 8000E LOTH, EADOIAt, ELOODM7.1. mid ELOODM211 me avai n 120y act MY ' SM( saes are &stable with 85, CP10id', ' 98+CR Is madil9e In 27K 30F 1-0 I^ . A, LOTH and LUT2w. OMM A.uibd0 for luminaires up, Is 3000L "UIIFTB Avaiablo [or kill**%up to 151p1 42Ma4nce lest me for Cored Options el vww.luseelrte.com U� o IH( W is U o udN O oto Y> � d0 ��l( 3W x 0U 7d� 7 o �4 W „ 'V W Din Cd0 0 U a - y� Q cU E z C7 0 s o � � o C!1 0 > On d 1--� H W > W Z O 14 CA OpZW W 4 � 5 m U Z O d zo f0 Z z 0 0 U U Z Z Z Z 0 0 O O V V O O � � W Q � N O a W O O I,0 0p ti D � I � Jimmy L. Taggart Up. No. 22841 1 A�OF 08/03/2020 l$w '&&TONAL RaG U_ J Ir 0 z 5 U w a = Q a Q W 0- a z W '�^ 'o^ � v 1 (lJ � it C) Is7 ~� X F+ W z H ~ o a �0 V DATE: 10-25-2019 SCALE: NA JOB: 19.0125 SDP-2019-00062 12 SHEET: OF 13 F/ D-3A. 38. 3C EXPANSION KEYED TCONST. BARB JOIN BM G 0 BM C 2„ I z ARS F !r I ,a I I��,II ---------------�--.'•�i�Jl• �� l 'aazm PLAN a'-u- f%­-B SIX w� in t• ------------- - - - - - - -- I - BARS i BMS E Lee_B -0 3" DIAMETER KEYED CONST. JOINT A E WEEP HOLE FRONT ELEVATION SEES F-' / - r-e^ 6^ BMs B -N-4 - (GUTTER REMOVED) Y/4"r*�� SECTION B-B 5%' "BEN 8" � , N TYPE A NOSE METAL SHONL BE USED WITH CF3 M CG4 STANDARDSL2 "%21TYP N DE AL SHN1 BE U D W TH CG- I C-6 TANDMDSGAL1 DE B OSE SE 2 C S T A TYPE TYPE B I % 4" SSTEM CONNECTOR WELDED CONVECTO IRON PLATE FOR TYPE A TO BE BENT AN ANGLE OF 68•}0' TO ANGLE IRON AT 2-C-C. CONNECTORS AND IS BE ENCHOREp WITH 1/2"2" p• % 4" STUD SHEAR NOSE DETAILSWELDED TO BENT PLATE AT 2-C-C. 2" APPR. PAVEMENT DF3A L DI-38 L 01-3c L -!-' WARPED PAVEMENT `�pW FLOW711. OW ..-•. p.p.. DETAIL WHEN USED FOR USE ON GRADES ADJACENT TO CURB FOR VSE N SAGS WITHOUT GUTTER BOTH SOEB i0 BE SYMMETRICAL �VDOT SPECIFICATION ROAD AND BRIDGE STANDARDS STANDARD CURB DROP INLET REFERENCE SHEET I OF 2 REASON DATE 12" - 30" PIPE: MAXIMUM DEPTH (H) - 8' 233 104.09 08/10 VRGMA DEPARTMENT OF TRANSPORTATION 302 2016 ROAD & BRIDGE STANDARDS EMBEDMENT SPRING LINE OF PIPE NO. 68 STONE 8"MIN TABLE OF QUANTITIES DI -}A 38 3C TYPE L AREA OF SLOT REINFORCING STEEL Concrete BAIRS BARS 8 PAIRS C BARS D BARS E BARS F BARS G WEIGHT Ft. . FL Co. No, F Lin. FL • No. Le,. Ft. • N1 Lin. FL 8r No. Lin. FL No. Lin. Ft W NO. Lin. F1.4 No. Lin, CDs. DI-3A Y'-6" 1.15 6 2.26 - - - - I 5'q" 3 3'-2" - - - - 6 11- 1, 22 4' 1.83 2.59 5 T.I.. 2 6'-T' - 3 5'O" 3 3•.2•• 4 1'-6" 3 1'-6" 4 T- " 64 ] 5 3'-6" _ _ _ T• 3 }•-2•' 4 - 3 1'-6" 4 67 .4 5 5'-6" 10 -7" 3 3'd•' 4 T- . 3 I'-6" 4158 DI-3B 10' 4. s 7--6" 14 6•-7" to 6'-10" '• " 3 Y' 2" 4 3 V-6" a - 1 ' 5.50 4.34 5 9'_6•' IS _ _ •-7" } y-2•' 4 •-6" 3 1'-6" 4 1 14' 642 4.78 5 11'-I" 22 6'-7" - •• 3 51.711 3 3•-2" 4 11'-6•' 3 I'-6" 4 '- 16' 7.33 522 5 IS-6" 26 '-T' -I " 3 5'-7" 3 Y-2" 4 11'-6" 3 1'-6" 4 P- 4 1 5 15'-6" 0 '- " '- '•-7" 3 3'-2" 4 1 '- " 3 I'-6" 4 '- 1 20' 9.17 6,09 5 O'-6" 34 6'O" to 6'-10" 3 5'-]" 3 3'-2" 4 IT-6" 3 T-6" 4 I'- " 438 6• 2.75 3.01 10 1'-9" 4 6'-7" to V-IU" 5 5'-7" 3 3'-2" 8 Y-9" 8 T.6" 2 1'- " T1 8' 3,67 3-45 1 10 T-9•' 8 1 6'-7" to V-D" 1 5 1 5'-T' 3 3'-2" 1 8 2•-94' 6 V-6" 2 T- " 158 ICr 4.58 10 3;_g�; 12 6._]. t _D.. ._ ,. } .. ;� ._ . P_6.. 2 DI-3C 14' 6.42 4.77 10 5'-9•' 20 6'-7" to 6'-D•' S 5'-7" } Y-2" 8 5'-9" 6 1'_6.• 2 16' 7.3 .21 to 6'-9" 24 '- " '- ^ 5 5'- " } 3'-2" 6'-9" 6 I'_6" 2345 18' 8.25 565 1 D 1 7'-9" 1 28 1 6'-7k'to 6'-10" 1 5 1 5'.7'• 1 } 1 y_2` 1g p.g.• 6 p-6" 2 392 to 6'-1 " 1 5 1 5'-7" 1 } 1 3'-2" 1 8 1 8'-9" 1 6 1 F-6" 1 2 •_ •• 439 NOTES I. DEPTH OF INLET (H) TO BE SHOWN ON PLANS. 7. N4 X 8" SMOOTH DOWELS AT APPROXIMATELY 15. THIS AREA MAY BE EARTHEN, N WHICH CASE 12" C-C TO BE PLACED IN ALL AREAS ADJACENT THE EXPANSION JOINTS WILL APPLY ONLY TO 2. THE "H" DIMENSION SHOWN ON THE STANDAROS TO ABUTTING CONCRETE TO PREVENT CURB AND GUTTER, AND SPEOFED ON THE PLANS WILL BE SETTLEMENT. MEASURED FROM THE INVERT OF THE C TFALL 16. CONCRETE OUANTITES SHOWN ME FOR DEPTH PPE TO THE TOP OF THE STRUCTURE S. Y' DIAMETER WEEP HOLE TO BE LOCATED TO (H) OF 5'-2" WITHOUT PIPES THE AMOUNT PLAN "H" DIMENSIONS ME APPROXIMATE ONLY MAN SUBBASE MATERIAL. WEEP HOLE WITH DISPLACED BY PIPES MUST BE DEDUCTED TO FOR ESTIMATHG PURPOSES AND THE ACTUAL 12"X12" PLASTIC HARDWARE CLOTH I/4" MESH OSTNN TRUE QUANTITIES. FOR INLETS OF DIMENSIONS SHALL BE DETERMINED BY THE OR GALVANIZED STEEL WIRE, MINIMUM WIRE DIFFERENT DEPTHS AID OR SUBTRACT 0.32 CONTRACTOR FROM FELD CONDITIONS. KK DIAMETER 0.03" NUMBER 4 MESH HARDWARE CUBIC YARDS OF CONCRETE FOR EACH FOOT CLOTH ASTRUCTU FIRMLY TO THE OUTSIDE OF DEPTH. J. WHEN SPECIFIED ON THECO ALMS THE MVERT IS OF THE STRUCTURE. TO BE SHAPED H ACCORDANCE STANDARD 17. LENGTH OF ANGLE IRON AS SHOWN ON SLEET 1 MID THE COST OF FL AND PLACING ALL 9. ALL REINFORCING STEEL SHALL. HAVE A MIN. OF 2 6 TO BE L+16" AT 4.D CBS./FT.. MAT TO THE MATERIALS INCIDENTAL THE SHAMING IS TO BE COVER OF 2". RI INCLUDED N THE BD PRICE FOR THE STRUCTURE. 18. CH DENOTES LENGTH OF ONE Ell BM. B, ALL REINFORCING STEEL i0 BE CUT CLEAR OF IN THE EVENT THE INVERT OF THE OUTFONL ALL OPENINGS BY 2". 19. ALL REINFORCING BARB TO BE"5. 4. PPE THAN THE BOTTOM OF THE RE, THE STRUCTURE, THE INVERT OF THE STRUCTURE II. PLACE CONCRETE IS TO BE CLASS A7 20, WHEN INLET IS USED MEDIAN, BACK OF SHALL SHAPED WITH CEMENT MORTAR TO (3000 (3000 PSI). PRECAST CONCRETE IS TO BE HLET 15 TO RE SHARED TO CONFORM TO E TO T PREVENT STATURE OR PCOF WATER 4000 PSI. PROPOSED CURB. IN THE STRUCTURE. THE COST OF FURNISHING AND PLACING ALL MATERIALS ACCIDENTAL 12, LENGTH OF SLOT ICI WILL. IN EVERY CASE. BE THE SHARING TO INCLUDED W THE BID BITURE. SHOWN ON PLATS. PRICE FOR THEE STRUCTURE 13. INLET 5 CONSTRUCTED IN MEDIAN CURB OR s. STEPS ARE PROVIDED WHEN H W WITH INTEGRAL CURB. GUTTER IS TO BE OR GREATER.. FOR DETAILS A ST- DETASTANDARDLS BEE STANDARD ST-1. OMITTED (SEE DETAIL). 6. THIS REM MAY BE PRECAST OR CAST -IN -PLACE. 14. STANDARD INLETS MAY BE CONSTRUCTED WITH CONCRETE BLOCKS IN ACCORDANCE WITH THE DETAILS SHOWN ON STANDARD DRAWING DI-MB. REFERENCE STANDARD CURB DROP INLET " ROAD AND BRIDGE STANDARDS 233 12" - 30" PIPE: MAXIMUM DEPTH (H) - 8' REVISION Dare SHEET 2 OF 2 302 VIRGINIA DEPARTMENT OF TRANSPORTATION D4.D ILL SHALL 'K MATERIAL IN ANY 1IAL BACKFILL* LIFTS) THOROUGHLY COMPACTED BY HAND OR APPROVED MECHANICAL TAMPER 1UNCHING :DOING Be max 4" min WNDATION (SHALL BE NOTE : 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE BACKFILLED ENTIRELY WITH NO. 21A STONE. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF N0. 68 STONE SHALL BE PROVIDED' 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE' SEWER SERVICE LATERAL CONNECTION NOTES: 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST Of HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 09 (1/4" PER FOOT ) A ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN DIAMETER OF V. 5. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. SALT TREATED FINISHED GROUND MARKER PLUG END OF - MAIN UNE-HS I ____,_„ SERVICE LATERAL LINE WYE-TEE PLAN VARIES E SEWER SERVICE LATERAL CONNECTION N.T.S. FIG. S-2 TD-33 TYPICAL SEWER PIPE INSTALLATION IN TRENCH NTS FIG. S-3 TD-34 COVER LIFT NOTCH 14 1/2' 1 12 1/2' 2 3/8" WATER • CAST IRON UD 18' METER BOX 18" + •• 8" EXTENSION PIPE SLOT (2 PLACES) NOTES: (1) A 1-3/4" DIAMETER HOLE IS REQUIRED IN THE LID FOR TOUCH READ METERS. TYPICAL METER BOXES (5/8"-1" METERS) NTS FIG. W-7 TD-13 GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL B'?4- I B• INITIAL BACKFILL B24 1 B" MIN MIN. MIN. MIN. 6" BEDDING %'" #68 STONE * STABLE SOIL ROCK • SCRAPE THE BOTTOM OF THE TRENCH. REMOVE ALL STONES TO INSURE THE PIPE DOESN'T REST ON ROCK AND THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF #58 STONE FOUNDATION IN POOR SOIL UNDER -CUT CONDITION 4 I INITIAL BACKFILL 4 UNSTABLE e^ Be 5- SOIL MIN. M MN #68 STONE •+,, ANULAR FILL AS APPROVED BY ACSA / \ T STABLE SOIL OR ROCK, NOTE 1. NO ROCKS SHALL BE ALLOWED WITHIN 240 OF THE WATER LINES. 2. NO ROCKS LARGER THAN Be IN ANY DIMENSION SHALL BE ALLOWED ABOVE THE INITIAL BACKFILL 3.THE INITIAL BACKFILL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. 4. NO ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED IN THE TRENCH. 5. BELL HOLES SHALL BE DUG OUT IN ALL CASES. DUCTILE IRON WATER PIPE INSTALLATION & BEDDING NTS FIG. W-2 Ta2 CG-12 GENERAL NOTES: 1. THE DETECTABLE WARNHG SHALL BE PROVIDED BY TRUNCATED DOMES. 2. ALL DETECTABLE WARNING SURFACE PRODUCTS SHALL MEET THE REOUIREMENTS OF SECTION 504 OF THE SPECIFICATIONS FOR CG-12 DETECTABLE WARNING SURFACE. DETECTABLE WARNING SUFACE PRODUCTS USED SHALL BE FROM THE MATERIALS APPROVED PRODUCT LIST NUMBER 72. 3. SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP FLOOR OR BY USING PERMISSIBLE CONSTRUCTION JOINT WITH REOUIRED BARS. 4. REQUIRED BARS ARE E TO BE NO.5 X S" PLACED 1- CENTER TO CENTER ALONG BOTH SIDES COOF VER F/2RAMP FLOOR, MAD -DEPTH OF RAMP FLOOR. MINIMUM 5. ROADWAY CURB / CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS ARE INCLUDED IN PAYMENT FOR CURB / CURB AND CUTTER. 6. CURB RAMPS ARE REWIRED FOR SIDEWALKS AND SHARED USE PATHS. THE WIDTH OF TIME CURB RAMP SHALL MATCH SIDEWALK WIDTH. WHEN CURB RAMPS ARE USED IN CONJUNCTION WITH A SHARED USE PATH, THE MINIMUM WIDTH SHALL BE THE WIDTH OF THE SHARED USE PATH. 7. DETECTABLE WARNINGS SHALL EXTEND THE FULL WIDTH OF THE CURB RAMP LANDING FLOOR. B. CURB RAMPS WILL BE INSTALLED AND LOCATED WITHIN PEDESTRIAN CROSSWALKS AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER. CURB RAPS SHOULD NOT BE LOCATED BEHIND VEHICLE STOP LINES, LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. 9. RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT THE CURB OPENING IS PLACED WITHIN THE LIMITS OF THE CROSSWALK AND THAT THE SLOPE AT THE CONNECTION OF THE CURB OPENING IS PERPENDICULAR TO THE CURB. 10. DETECTABLE WARNING SURFACE PANELS SHALL BE INSTALLED FLUSH WITH THE BACK OF CURB. 11, WHERE CURB RAMPS INTERSECT A RADIAL SECTION OF CURB AT ENTRANCES OR STREET CONNECTIONS THE DETECTABLE WARNING SURFACE SHALL HAVE 5• A FACTORY RADIUS OR BE FIELD -MODIFIED AS RECOMMENDED BY THE MANUFACTURER TO MATCH THE BACK OF CURB, SEE CG-12-INS PAGES 204.06 MID 204.07 FOR METHODS OF INSTALLING DETECTABLE WARNINGS ON A RADIUS NOTE COMPONENTS OF CURB RAMPS CONSIST OF THE FOLLOWING- HYDRAULIC CEMENT SIDEWALK (DEPTH IN INCHES. AREA IN SQUARE YARDS) CURB WHEN REWIRED (CG-2 OR CG-3 IN LINEAR FEET) DETECTABLE WARNING SURFACE (AREA IN SQUARE YARDS) EACH OF THE ABOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CURB CUT RAMP. SIDEWALK RNAP 12�1 MAX 481 MAX 8 MAX 101 TYPE A PERPENDICULAR Y g' MH a W2l tbl MAX TYPE B PARALLEL ' AT W.. 2" HIGHER THAN EDGE OF PAVEMENT AT )KX . SAME AS TOP OF CURB TYPE C PARALLEL & PERPENDICULAR TRUNCATED DOME bi .6"-2.4" C-C o I 0 0 0 0 0 L O O O O O O O O O O O O 0 0 0 0 0 O O O O O O O TT LANDING RAMP + O 000 00 0 0 0 000 0000 la ;A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r 000000000000000 )? 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 /.-6 X DI DIAMETERTO AMETER 000 00 0 0 0 000 0000 DETECTABLE WARNING o AT BACK OF CURB 0.9"-1.4" SEE NOTE 11. BASE DIAMETER r VARIABLE FULL WIDTH OF RAMP FLOOR _ PAY LIMITS DETECTABLE WARNING TRUNCATED DOME DETECTABLE WARNING INSTALLED ON A RADIUS DETAL DETAIL `VDOT A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE SPECIFICATION ROAD AND BRIDGE STANDARDS CG-12 DETECTABLE WARNING SURFACE REFERENCE SKEET f OF 5 REVISION DATE (GENERAL NOTES) t05 s02 204.01 04/19 VIRGINIA DEPARTMENT OF TRANSPORTATION 504 FRAME & COVER (SEE FIG. S-I-D,E) STREET SURFACE OR NON -PAVED AREA SLOPED AREA 1'-O" MAX RUBBER COATED STEEL 3'-MIN STEPS CAST IN PLACE PRECAST REINFORCED � CONCRETE SECTIONS 12" MIN "0' RING SEALS " 16' MAX MINIMUM ELEVATION DIFFERENCE ACROSS M.H. 5" V- - FROM INLET TO OUTLET SHALL BE 0.20 FEET. - DEFER FLOW �FILNCR P VARIES LETS CHANNELL TO BE 3/4 DIAMETER OF S•�---- CONTRIBUTING -- SEWER. ••, 12" ' •4 A FILLETED INVERT OR A SM00 . •,!': TRANSITION OF FLOW BETWEEN M'QPWMIN. INLET & OUTLET PIPE SHALL BE PROVIDED, 6" BEDDING NOTE : W/ NO. 68 STONE 1. BEDDING THICKNESS REQUIREMENT SHOWN IS MINIMUM AND SHALL BE SPECIFICALLY DETERMINED BY THE CONSULTANT FOR THE SOIL CONDITIONS. 2. THE CONSULTANT WILL DETERMINE WHETHER MANHOLES SHALL HAVE EXTENDED OR NON -EXTENDED BASES. 3. ALL JOINTS, LIFT HOLES, INLETS, OUTLETS TO BE SEALED & GROUTED INSIDE AND OUT. TYPICAL MANHOLE SECTION SHOWING BRANCH TIE-IN N.T.S FIG. S-I-A M-25 NUTS HYDRANT MUST BE EQUIPPED WITH ORAINDTIES- VI1 E THI READS M#OH IS QTHE LOCAL STANDARD. LENGM OF BRANCH VARIES 6' MN 2" TO 10 (2�7 7 DU. FT. ALVE Box #68 STONE 42•MIN ';� .' 6^ GATE •�., VALVE ' �' • WEE 2500 P.S.I. CONCRETE / Ivt .E ' T'( BASE AND THRUST ; i I } •; BLOCK AGAINST ', \\V/f UNDISTURBED STABLE SOIL STEEL PILE RESTRAINED JOINT FITTINGS WHEN THE SOIL IS DISTURBED OR WHEN A HYDRANT IS LOCATED IN A FILL N ADDITION TO POURING CONCRETE, A STEEL PILE SIWE BE USED AS ADDITIONAL SUPPORT. NOTE : 1. SURRCUND MEEP HOES WITH GRAVEL AND KEEP FREE OF CONCRETE. 2. MAINTAIN A 3 T/2• RBN. MYER FROM THE MAIN TO THE FIRE HYDRANT ( INCLUDING DITCHES ) 3. FINISHED GRADE SHALL SLOPE AWAY FROM THE FIRE HYDRANT AND VALVE BOX. 4. THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH, IT IS NOT ALLOWED IN THE DITCH 5. FIRE HYDRANTS SHALL RE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE ABOVE THE PREVAILING GROUNDWATER ELEVATION. IF REQUIRED TO BE IN WET AREAS, THE WEEP HOES SHALL BE PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. TYPICAL FIRE HYDRANT ASSEMBLY DETAIL N.T.S. FIG. W-4 Tab PLACE 5' GALVANIZED " WITNESS " POST WITH CAPPED ENDS PAINTED BLUE IN REMOTE AREAS c AS DIRECTED. MARKER LOCATION MAY BE SUBJECT p TO HIGHWAY DEPARTMENT APPROVAL. FINISHED GRADE c ADJUSTABLE TRAFFIC RATED II VALVE BOX W/ LID II a D Z Z M.J. GATE VALVE WATER LINE 2500 P.S.I. ' CONCRETE '• 1 A 2'x 2' BEARING AREA. THRUST BLOCK '; a A e • d . a .. All NOTE : IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (8) INCHES ABOVE GRADE. TYPICAL GATE VALVE NTS FIG. W-5 TD-9 TYPE 8 PARALLEL APPLICATION ROADWAY GRADE IN PERCENT MINIMUM RAMP LENGTH IN FEET P' CURB 6" CURB 0 4 6 1 5 7 2 5 8 3 6 9 4 8 12 5 t0 15 6 14 IS lz 3000 PSI CONC. BASE BENCH SLOPED TO FLOW CHANNEL 1/4" : V MIN n t- r �i1 BRANCH 12 R ) p- 2„ FLEXIBLE CONNECTION NOTE: WITH STAINLESS STEEL ALL CONNECTIONS TO BAND EXISTING MANHOLES SHALL BE CORED AND A FLEXIBLE CONNECTION " BOOT " o INSTALLED TYPICAL MANHOLE PLAN SHOWING BRANCH TIE - IN NTS FIG. S-1-B TD-27 V COMPRESSION A 3/4• MALE PIPE APPROVED EQUAL i=PUNGOOR PE •HODPAFOR USE ON ATTACHED SINGLE FAMILY RESIDENTIAL SERNOES M DUAL RESIDENT& MID IRRIGATION SERVICES. TEE 0 NOTE NO SWFAIEO NTTNCS � 1, DUAL SERVICE V CONPR66NON % 8/4• MARE PIPE CQUPLRA OR APPROMW EQUAL I" TSPE -M' )OFT COPPER W FOR USE ON DETACHED SINGLE FAMILY RUIDBMAL SERMCE "ERE M IRRIGATION METER IS NOT PROMISED. SINGLE SERVICE � ITZI DUES SHML BE USED EN PVC NNE, CAST IRON UD MISHFO GRADE IY5-10 LOCNNNG ME= e. BOX W MIN. MPPERSETRA 1/8 BEND CMPUNO� y - METER CORPORATION 8TOP • ,y(��4�5• �, BRICK AS NECESSARY SANG tlt MST UNOER �ti,i ,A'N,. H,yw�TNM,-T 4• DIAMETER DRAIN PIPE 12• Nl( AW 9E11ER (2-INCH i Vv,.' .' J LONG SINE POCKET, ,�, t WOT M WMUM maxx I ''v,'.. w'y'.r \*''Tq SPEC. 203, NO. 57 AGGREGATE TYPICAL SERVICE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W-BA TD-10 VARIES VALVE BOX 4•• DIAMETER BRANCH AND VALVE M.J. PLUG VARIES 7 `\ WATER MAI RESTRAINED JOINT MTRNGS ON-LINE (TYPE "BIN) VARIES THREADED COUPUNG PVC SLEEVE BRASS NIPPLE AND PVC o CAP T LUBRICATE ALL THREADS THRUST BLOCK METER BOX (SEE FIG. W-7) VALVE NO. 57 STONE M.J. FITTIN 2" PIPE SLOPED TO DRAIN IF - GRADE ALLOWS VARIES VARIES 2" BRASS PIPE WATER MAIN AND VALVE 2" THREADED TAP ARE SAME SIZE PLUG DEAD END (TYPE "A") TYPICAL BLOW -OFF ASSEMBLY NTS FIG. W-8 Tots -FINISHED GRADE AIR RELEASE VALVE PIPE BRONZE GATE �BRRAApSNNS'7EOOoRGGBRONZE IF PIOSSIBLERADE h. gq� K g� p p7� p SOLSD CEMPEHPT BL & CRUSHED STONE 7yyppgg KK SOFT CORPORATION STOPCOPPER" NOTES: 1) A PRECAST MANHOLE CONE AND COVER WITH WATER CAST ON LID FOR TRAFFIC AREAS, OR A METER BOX ASSEMBLY IN NON -TRAFFIC AREAS, OR APPROVED EQUAL, SHALL BE USED. 2) FOR WATFsRUNES SMALLER THEN 12" USE A 1" A.R.V. AND FITTINGS, FOR WATER UNES 12 AND LARGER USE 2 A.R.Y. AND FITTINGS. 3) IN SITUATIONS WHERE THE A.R.V. ASSEMBLY CANNOT BE OFFSET FROM THE MAIN AN ADEQUATE FOUNDATION SHALL BE INSTALLED SO THE WATER LINE DOES NOT SUPPORT THE MANHOLE CONE. AIR RELEASE VALVE (ARV) NTS FIG. W-9 TD-20 V a W a' N Q (N L� u Z Q D Q( 20 UE� 4 J 0 0 IK Ld OZW JJ Cf)Q CC LLJ LU or- I C) Q 00 _J N Q a ? Q LLO Wu�Zcc00) O� N 0 M 0 v Ir X It 0 LL y aIII� wL0 ^ U0 ( Q 0 Son L I PIP to rn W :Tco co W 2 Z OW�a i PtiTH OF Gf cam, U /,7 ! 9 Jimmy L. Taggart LiC. No. 22841 W4 lli A'4'QF, 07/30/2020 -1{{ �SSIONAL E�0 U_ ,J Z � co Lu J a U H a _ < j A zI o cn 5 CO- a U a 0 IL 0 Z ~ W � z z z 0 'V fr 00 //0'R V DATE: 10-25-2019 SCALE: NA JOB: 19.0125 SDP-2019-00062 SHEET: 13 OF13