HomeMy WebLinkAboutSDP202000023 Review Comments Final Site Plan and Comps. 2020-08-170 County of Albemarle Department of Community Development Memorandum To: Scott Collins, P.E. (Scottkcollins-en ing eering com) From: Cameron Langille — Senior Planner II Division: Planning Services Date: April 23, 2020 First Revision: June 29 2020 Second Revision: August 17, 2020 Subject: SDP202000023 — Martha Jefferson Hospital Presidia Apartments — Final Site Plan The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approval of the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Applicable Comments from Initial Site Plan Action Letter (February 7, 2020): 1. [ZMA200100015]: The development appears to be in general accord with the approved ZMA-2001-00015 (including Exhibit B — Application Plan, sheets API-AP6): the residential use and number of dwelling units are in general accord with what is shown as Parcel I containing 250 residential units on AP-4; and the open space, trails, and pedestrian connectivity are in general accord with what is shown as Parcel J on AP-4 and AP-5, and as Anticipated Pedestrian Route — Connection to Gateway on AP-6. First submittal: Per proffer #4 of ZMA2001-15. reasonable Dedestrian access needs to be Drovided through the site down to the Countv owned ereenway. A 10' Class A asphalt path has been provided at the southern end of the development down to the erg enway. It appears that the path goes onto TMP 07800-00-00-020M1 which is owned by Worrell Land & Development Company LC. Please address the following: an easement over the 10' wide pedestrian path should be provided, owners of TMP the applicant is working with the owner of TMP 78-20M1 to prepare a boundary line adjustment, land reservation plat to obtain acreage from TMP 78-20M1 to incorporate into TMP 78-20M5. This will create a connected area of land from Peter Jefferson Pkwy to the existing Co"greenwaysystem adjacent to the river. This plat will be submitted to the County for review, approval, and recordation prior to final site plan approval. 3'" Submittal: SUB2020000130 has been submitted which shows the new easement. Once that plat is recorded, please update the site Dian so that the easement labels state the recorded instrument deed book and Dade on all applicable drawings. Additionally. staff acknowledges that the apDlicant has Drovided a 5' sidewalk through the site to access the 10' path. Staff with CDD and the Parks & Rec Department have evaluated the proposed pedestrian route through the site. See comment #3 from Parks & Recreation staff below. Several options are available that can be done on revised plans to accomplish the proffer's intent for providing reasonable access to the regr enway. This could include one or more of the following options (or a combination thereof): a. Providing a publicly -accessible trail connection (Class A shared use path: 10' wide / asphalt surface) through the property on the west side of the proposed private travel may. connecting to sidewalk along Peter Jefferson Parkway; and/or b. Revising the proposed private on -street pedestrian facilities (5' sidewalk) along the proposed private travel way to instead be a Class A shared use path (10' wide / asphalt surface) and providing a public use access easement: and/or C. Adjusting the —4.5-acre "special lot' to increase in size, so as to contain additional acreage to the west of the proposed private street, in order to create more opportunity/flexibility to install a public bike/ped connection through this physically constrained area that contains substantial steep slopes. A public access easement will need to be provided through the site over the pathway. Please see comment #3 under "New Comments Final Site Plan" section below for more information regarding the easement. 21 submittal: Please provide a variable width public access and use easement ex licitly for public bike/ped use) over one of the proposed travelways and over a portion of the proposed sidewalks on the Presidio property (TMP #78-20M6). Such an easement will ensure that members of the public will have reasonable access between the Peter Jefferson Parkway public right of way and the Rivanna Greenway property owned by the County prior to County construction of a shared use path (or other type of recreational connection) within the Presidio Special Lot (TMP #78-20M5). Specifically, in order to ensure that the proposed development `will provide reasonable provisions for access to the Greenway System" concurrent with the commencement of the proposed use(ss). See Parks & Rec. comment for description of requested easement locations inside of the Presidio site. 31 Submittal: SUB2020000130 has been submitted which shows the new easement. Once that plat is recorded, please update the site plan so that the easement labels state the recorded instrument deed book and pace on all applicable drawings. 2. [Section 32.5.2(a)]: The title on the Cover Sheet (Sheet IA) incorrectly states that this application is a "Final Site Plan." This application has been submitted, processed, and reviewed as an "Initial Site Plan." First submittal: Comment no longer applicable. 3. [Section 32.5.2(a)]: If the Open Space contained in the recently -created Special Lot (approximately 4.5 acres, identified as Tax Map/Parcel #78-20M5) is included in the calculations for this site plan, then please add this Tax Map/Parcel number and acreage to the "Tax Map No." and "Total Project Area" information in the General Notes on the Cover Sheet (Sheet IA). Please also correct any density calculations that may change based on revisions to the project area acreage. First submittal: Comment addressed. Only TMP 07800-00-00-020M6 is included in the acreage. 4. [Z.O. Section 32.5.2(a)]: Please identify Tax Map/Parcel #78-20M5 on the Overall Layout Sheet (Sheet 3) and include a note identifying it as Open Space reserved for future dedication to the County for public use. First submittal: Comment addressed. 5. [Z.O. Section 32.5.2(i), (j), (k), (1)1: Please ensure all existing and all proposed public and private easements are shown and labeled. First submittal: Comment not fully addressed. There is a conservation easement recorded in DB 2544, pages 243-251 that appears to now be located within both TMP 78-20M5 and 78-20M6. Please show this easement on the plans. Per the restrictions in the recorded instrument, limited activities may occur within that easement. Please provide a written response verifying that the applicant and owner have researched this and that the proposed site development complies with the restrictive covenants. Refer to DB 2607 PG 572-575 for other easements to which the property may be subject and show those easements that are located within TMP 78-20M6. 2°d submittal: Comment addressed. 6. [Z.O. Section 32.5.2(i), 0), (k), (1)1: Please ensure Deed Book/Page references are included for existing easements. First submittal: See comment #5, add DB/page references for existing easements. 2"d submittal: Two easement plats, SUB202000089 and SUB202000115, are currently under review and will create new easements associated with the project. These must be approved and recorded prior to final site plan approval. Once these easements are recorded, Please update the site plan so that all deed book and page numbers for recorded instruments are updated. 7. [Z.O. Sections 32.5.2(a), (b), (n), and (s)]: Please ensure that all portions of the subject property are included on each applicable Sheet. Staff acknowledges the Match lines on Sheets 2 and 3 (shown at a scale of 1' = 50'). However, other sheets (shown at a scale of 1" = 30') do not include all portions of the subject property; for example, the Layout Plan (Sheets 4 and 5), the Utility Plan (Sheets 6 and 7), and the Grading & Drainage Plan (Sheets 8 and 9) exclude the northwestern and southwestern portions of the property. First submittal: Comment addressed. 8. [Z.O. Sections 32.7.2.3 and 4.12.61: (Advisory Review Comment) — Based on the proposed number and types of units, a minimum of 425 parking spaces are required. Staff acknowledges that the "Parking Required" and "Parking Provided" sections of the "General Notes" on the Cover Sheet (Sheet IA) indicate that 426 spaces are provided, including 406 surface parking spaces and 20 garage spaces. Staff further acknowledges that 14 parking spaces appear to provide universal access towards meeting ADA requirements. First submittal: See comment #1 under the "New Comments Final Site Plan' section below. 9. [Z.O. Section 32.7.2.31: (Advisory Review Comment) — Staff acknowledges that a 5' wide concrete sidewalk is proposed in multiple locations throughout the development, including along Peter Jefferson Parkway between the (proposed) eastern entrance and the northwestern property boundary, in order to establish a safe and convenient pedestrian connection to adjoining properties and adjacent employment centers. Please note that this connection must be designed and constructed to the standards established in the Albemarle County Design Standards Manual, provided that all ramps for persons with mobility impairments shall be designed and constructed to the standards of VDOT. First submittal: Comment addressed pending confirmation from Engineering Division staff. 2nd submittal: Comment addressed. 10. [Z.O. Section 32.7.2.31: (Advisory Review Comment) — Staff acknowledges that a direct "pedestrian walkway" or pedestrian connection is proposed across Peter Jefferson Parkway, in order to enable safe, convenient pedestrian access between the subject property and the Martha Jefferson Hospital property. Please note that this connection must be designed and constructed to the standards established in the Albemarle County Design Standards Manual, provided that all ramps for persons with mobility impairments shall be designed and constructed to the standards of VDOT. Please also note that this proposed "pedestrian walkway" or pedestrian connection is subject to VDOT acceptance of a "justification report" as outlined in previous review comments provided by Mr. Adam Moore, PE (dated 5/16/2018). Community Development staff remain available to assist with the coordination of this "pedestrian walkway" at an unsignalized location. And CDD staff strongly support this proposed pedestrian crossing at an unsignalized location in order to: a.) proactively address the likelihood of frequent pedestrian crossings of Peter Jefferson Parkway at a location that would otherwise be unprotected and unsafe, and b.) to facilitate safe, convenient pedestrian mobility between places of residence and a major place of employment. More specifically, it can be reasonably anticipated that a relatively large number of pedestrian trips will occur on a daily basis between the two hundred fifty (250) dwelling units and Martha Jefferson Hospital. Even factoring in the provision of a new sidewalk along Peter Jefferson Parkway (as required pursuant to Zoning Ordinance §32.7.2.3, and as acknowledged above in Planner review comment #9), if no such pedestrian walkway is provided across Peter Jefferson Parkway then residents of the proposed apartment complex who want to walk from the apartments to the hospital would have to choose to walk approximately 3,000 linear feet on sidewalks, crosswalks, and walking paths in order to safely access the hospital — and would have to choose not to exit the development, cross Peter Jefferson Parkway (without any safe pedestrian infrastructure), and access the hospital via a much more direct route that is approximately 550 linear feet in length. A diagrammatic exhibit illustrating this issue is provided with this SRC review comment letter packet for reference. First submittal: Comment addressed. see VDOT comment letter. 11. [Z.O. Sections 32.7.2.3 and 25A.51: Staff acknowledges the provision of safe, convenient on -site pedestrian connections in many locations throughout this proposed development. However, staff have identified strategically important locations where additional safe and convenient on -site pedestrian connections are necessary. These connections must be designed and constructed to the standards established in the Albemarle County Design Standards Manual, provided that all ramps for persons with mobility impairments shall be designed and constructed to the standards of VDOT. Specifically, such safe, convenient pedestrian connections are required in the following general locations, as described below (listed a-d) and as conceptually shown below (in pink): / INPI / / 0 _ \ \ A G (PL /� NPI ITVP) \ LSR os (TYP) N� \I \ \ �p,� ✓ ITYPI IV CLUBHOUSE \ ) Ge \ ! (TYP) i' �. ce / ` BUILDING �. Jy (NPI / \ f 3/4 STORY IrvPI r/ \ / � 42UNI L UNITS BUILDING 4' i _ IrPI �j 4 STORY BLDG / N a) Between the Clubhouse and Building #1; First submittal: Comment addressed. b) Between the Clubhouse and Building #2; First submittal: Comment addressed. c) Between Building #3 and Building #2; First submittal: Comment addressed. d) Between Building #3 and Building #4. First submittal: Comment addressed. 12. [Z.O. Section 32.5.2(b)]: Please revise the sub -heading for the "Critical Slopes" section within the General Notes on the Cover Sheet (Sheet 1A) to "Steep Slopes Overlay District." Technically, there are no "Critical Slopes" within the Development Area; and Steep Slopes are technically an overlay zoning district. First submittal: Comment addressed. 13. [Z.O. Section 32.5.2(n)]: Show the proposed location(s) of outdoor trash containers. Staff acknowledges that the "Trash Receptacles" section within the General Notes on the Cover Sheet (Sheet 1A) references the proposed provision of a dumpster and trash compacter. Please also provide additional waste and recycling containers in the developed recreation areas and within other areas of the proposed development and show these on the final site plan. First submittal: Comment not fully addressed. As shown on the plans_ the concrete nad at the trash receptacle area does not extend at least 8' beyond the front of the dumpster, as required under Section 4.12.19 M. Please draw a concrete pad extending at least 8' beyond the front of the dumpster on all applicable sheets. Additionally, no screening details have been provided, as required by Section 32.7.9.7 (a)(3). Please either provide landscaping or a constructed screen around the trash receptacle area. If a wall or fence will be provided, please provide a cut sheet detail of the fence/wall in dumpster pad and enclosure on Sheets 3 and 5 so that it states "brick enclosure shall be at least 6' in height." 3' Submittal: Comment addressed. 14. [Z.O. Section 32.5.2(n)]: Show the proposed location(s) of outdoor lighting. Staff acknowledge that the "Lighting" section within the General Notes on the Cover Sheet (Sheet 1A) indicates that "Parking lot and building lighting is included with this final site plan." However, no such lighting information appears to be provided. Please note that a Lighting Plan that demonstrates compliance with Z.O. Sections 32.6.21 and 4.17 is required with the Final Site Plan application. First submittal: See comment #2 under the "New Comments Final Site Plan" section below. Additionally, because the subject property is within the Entrance Corridor Overlay District, this proposed project (including the Lighting Plan) is subject to review by the Architectural Review Board (ARB) and ARB staff, and approval/issuance of a Certificate of Appropriateness by the ARB is required. Staff acknowledges that application ARB-2019-00145 was submitted for review on 11/25/2019, and was then deferred indefinitely by the applicant(s) on 12/30/2019. First submittal: See comment #2 under the "New Comments Final Site Plan" section below. 4 15. [Z.O. Section 32.5.2(p)]: Staff acknowledges the Landscape Plan sheets (Sheets 12, 13, and 14).Because the subject property is within the Entrance Corridor Overlay District, this proposed project (including the Landscape Plan) is subject to review by the Architectural Review Board (ARB) and ARB staff, and approval/issuance of a Certificate of Appropriateness by the ARB is required. Staff acknowledges that application ARB-2019-00145 was submitted for review on 11/25/2019, and was then deferred indefinitely by the applicant(s) on 12/30/2019. First submittal: See ARB comments below. Once the ARB has issued a COA, this comment will be addressed. The plan is tentatively scheduled to go to the ARB in May. 2°d submittal: Comment addressed. ARB has approved the site plan, see APB comments below. 16. [Z.O. Sections 32.5.2(n) and 4.16]: The proposed development does not contain all of the required developed recreation areas and minimum facilities. Specifically, Z.O.4.16.2 ("Minimum Facilities") requires the following: a. Z.O. 4.16.2.1: One (1) tot lot (2,000 SF minimum) shall be provided for the first thirty (30) units and for each additional fifty (50) units. First submittal: Comment was informationaL b. As applied to SDP201900075: (250 units = Five (5) tot lots / minimum 10,000 SF total; see 4.16.2.1 for full details of this requirement). First submittal: Comment was informational. c. Z.O. 4.16.2.2: One-half (1/2) court for basketball shall be provided for each one hundred (100) units. First submittal: Comment was informational. d. As applied to SDP201800018: (250 units = Two (2) half -courts or one (1) full -court; see 4.16.2.2 for full details of this requirement). First submittal: Comment was informational. However, pursuant to Z.O.4.16, the planning director has some discretionary authority to consider proposed substitutions for the facilities that are required by this section of the Zoning Ordinance. The proposed provision of "trails/walking paths" which "shall be available for public use to access the Rivanna River trails" in lieu of some of the minimum required facilities would likely be partially acceptable and partially unacceptable. Please revise as follows: A. Provide the correct calculations (SF) of the required recreation facilities (info summarized above) by revising the "Recreation" section within the "General Notes" on the Cover Sheet (Sheet IA). First submittal: Comment addressed. B. Clarify the proposed recreation facilities; the General Notes on the Cover Sheet (Sheet IA) indicate that the proposed total area for recreation would be 51,200 SF (in the "Recreation" section), but the General Notes also indicate that the recreational areas equal 0.83 acres (in the "Land Area" section). First submittal: Comment addressed. C. Provide a recreation facilities proposal for review by the Planning Director and Chief of Planning that includes the calculations requested in comments # 14-A, and which describes any and all requested substitutions from the required minimum facilities (such as trails/walking paths, clubhouse and pool, dog park, etc.) with supporting explanations/rationale. First submittal: The plan has been updated to show the proposed recreational substitutions. However, a formal written request letter must be submitted so that it can be forwarded to the Planning Director for review. Include the require recreation calculations, and provide the proposed recreation area calculations and a description of the facilities themselves (for example, indicate what, if any, improvements will be provided within the beer garden and courtyards. Explain whether any fitness equipment or exercise areas are included in the 14,000 sq. ft. clubhouse). Also, is the 9.600 sq. ft. area figure of the walking trail the area within the dashed lines_ as shown on Sheets 3 & 5? Is the dashed line supposed to represent an access easement? 2' submittal: Formal substitution request has been received. The proposed substitutions meet the minimum area requirements of Section 18-4.16.1. However, additional details are needed regarding how the proposed substitutions are equivalent to the minimum facilities specified by Section 18-4.16.2. Please provide additional clarification about the types of facilities/equipment that are proposed in the 12,650 sq.ft. active recreation courtyard. Is this area just goingto o be grassed? Per Section 18-4.16.2.1_ substitution requests can be approved provided that proposed equipment and facilities "are appropriate to the needs of the occupants." Based on the description of the recreational areas in the substitution request, it appears that no tot lot equipment is provided at all, as required by Section 4.16.2.1. Since multifamily dwelling residents typically include younger children, staff can support the substitution request if the minimum facilities required for one (1) tot lot are provided on the site plan. Please provide a response and update the substitution request/site plan as necessary. Staff suggests converting the proposed beer garden into a tot lot that contains the facilities as described in Section 18-4.16.2.1. Cut -sheets of playground equipment will need to be provided on the construction detail sheets. 3'd Submittal: Comment addressed. Charles Rapp. Director of Plannin¢, has approved the recreational facility substitution request. No tot lots are needed. D. Please review the proposed locations, alignments, material specifications, and "Classification" of the "proposed primitive trail way," and any other proposed or potential trail or park infrastructure, in collaboration with Mr. Dan Mahon in the Albemarle County Parks & Recreation Department (ACPR). First submittal: A callout on Sheet 5 states that there is a gate on the path and to refer to the detail on Sheet 10. No gate detail is provided on Sheet 10. Please verify whether a gate is proposed, and the purpose for the gate. 2°" submittal: Gate has been removed from Sheet 5, comment addressed. As stated in comment #1 above, staff is requesting revisions to the proposed public access. If the 5' sidewalk on the east side of the western travel way will be converted to a 10' wide Class A asphalt path throughout the site up to Peter Jefferson Parkway, this comment will be addressed. If the applicant chooses one of the other options mentioned in comment #1, staff will review this on a future submittal to verify whether it provides reasonable access. 21 submittal: Public access proposal has been revised since first submittal after conversations between the applicant and Parks & Recreation staff. Applicant proposes to reserve land on TMPs 78-20M1 and 78-20M5 for future dedication to public use so that a trail system can be built by the County in the future to enable access to the existing greenM, Wr ZMA2001-15. Please provide a variable width public access and use easement ex licitly for public bike/ped use, over an internal travelway and sidewalk on the Presidio property (TMP #78-20M6). Such an easement will ensure that members of the public will have reasonable access between the Peter Jefferson Parkwakpublic right of may and the Rivanna Greenway property owned by the County prior to County construction of a shared use path (or other type of recreational connection) within the Presidio Special Lot (TMP #78-20M5). Specifically, in order to ensure that the proposed development "will provide reasonable provisions for access to the Greenway System" concurrent with the commencement of the proposed use(ss). See Parks & Rec. comment for description of requested easement locations inside of the Presidio site. 31 Submittal: SUB2020000130 has been submitted which shows the new easement. Once that plat is recorded, please update the site plan so that the easement labels state the recorded instrument deed book and pace on all applicable drawin¢s. Furthermore, please revise the callout on Sheet 13 for the trail. It states that it will be gravel. 2°" submittal: Comment addressed, labels have been updated to state that the trail will be a 10' Class -A Type 1 low maintenance asphalt trail. 17. [Z.O. Sections 32.5.2(b) and 32.5.2(i)]: In consideration of this subject property's strategic location relative to the Rivanna River, the Old Mills Trail, and the County's Rivanna Greenway and Blueway System, and following the extensive coordination between the applicant team and County staff in 2019, CDD-Planning staff believe additional coordination with Mr. Dan Mahon in ACPR is necessary. The purpose of this additional coordination would be to revisit the previous collaborative efforts related to park planning and trail planning efforts, and to review and (potentially) refine the proposed public access and publicly -accessible amenities that are shown and annotated on this site plan. a. Please note that ACPR staff have provided written review comments (dated 1/17/2020), which are attached to this comment letter. Please also note that Mr. Mahon intends to attend the 1/23 SRC meeting to represent ACPR and discuss these issues with the applicant team in person. First submittal: If the 10' wide Class A asphalt path is provided through the site and a new public access easement is provided over the path on both TMPs 07800-00-00-020M1 and 07800-00-00-020M6 as mentioned in comment #1, comment #16, this comment will be addressed. Otherwise, staff from CDD and Parks & Recreation will need to revisit this with the applicant to ensure that reasonable access is provided, per proffer #4 of ZMA2001-15.2nd submittal: Public access proposal has been revised since first submittal after conversations between the applicant and Parks & Recreation staff. Applicant proposes to reserve land on TMPs 78-20M1 and 78-20M5 for future dedication to public use so that a trail system can be built by the County in the future to enable access to the existing erg enwayper ZMA2001-15. Please provide a variable width public access and use easement ex licitly for public bike/ped use) over the travelway and sidewalk on the Presidio property (TMP #78-20M6). Such an easement will ensure that members of the public will have reasonable access between the Peter Jefferson Parkwakpublic right of way and the Rivanna GreenM property owned by the County, prior to County construction of a shared use path (or other type of recreational connection) within the Presidio Special Lot (TMP #78-20M5). Specifically, in order to ensure that the proposed development "will provide reasonable provisions for access to the Greenway System" concurrent with the commencement of the proposed use(s). See Parks & Rec. comment for description of requested easement locations inside of the Presidio site. 31 Submittal: SUB2020000130 has been submitted which shows the new easement. Once that plat is recorded, please update the site plan so that the easement labels state the recorded instrument deed book and page on all applicable drawings. 18. [Advisory / For Future Reference]: Please note that the following approvals will be required prior to County approval (as may be applicable) of a final site plan for this proposed project: a. [Z.O. Sections 32.4.2.2 and 32.4.3.31: Architectural Review Board Certificate of Appropriateness / ARB- 2019-00145. First submittal: See ARB comments below. Once the ARB has issued a COA this comment will be addressed. The plan is tentatively scheduled to go to the ARB in May. 2°" submittal: Comment addressed. b. [Z.O. Section 32.7.4.1(a)]: Water Protection Ordinance Plan (and corresponding legal documents) / WPO- 2018-00027. First Submittal: WP0201800027 is still under review. 2°" submittal: Comment addressed WPO201800027 has been approved. c. [Z.O. Sections 32.7.4.2 and 32.7.5.31: Easement Plat(s) (and corresponding legal documents) / SUB-2019- 00084 and SUB-2019-00118. First Submittal: See comment #3 under the "New Comments Final Site Plan' section below. 2"" submittal: Per previous comments, once the easement plats. SUB202000089 and SUB202000115 are approved and recorded, update all blank labels so they state recorded instrument number. Furthermore, once the BLA/special lot plat. SUB202000016. for TMP 07800-00-00-020M5 is approved and recorded, update the parcel label so it states the correct acreage and recorded instrument for that property on all applicable sheets. 3'd Submittal: Once SUB202000089. SUB202000115. and SUB202000130 are recorded. please update the site plan so that all easement labels and property labels specify the recorded instrument numbers and accurate acreages of the parcels. d. [Z.O. Section 32.7.1.11: Special Lot Plat / Note: Staff acknowledges approval and recordation of Special Lot Plat SUB-2019-00034. First Submittal: Comment addressed. e. [Z.O. Section 32.4.3.6(a) and 32.4.3.6(c)]: Tentative approvals (review status of No Objection") from all applicable SRC members for final site plan. First submittal: See comments from other reviewers below. This New Comments Final Site Plan 1. 132.7.2.3 and 4.12.61 Please make the following revisions related to parking: a. On Sheets 3 & 5, please draw the missing 131 parking space in the row of parking in front of Building #5. 2°d submittal: Comment addressed. b. On Sheet 5, there is a row of parking that totals 14 spaces in front of Building #5, but the callout states 15. Please revise the callout. 21 submittal: Comment addressed. c. On Sheets 4 & 5, there is a row of parking in front of Building #4 that totals 16 parking spaces, but the callout states 18. Please revise the callout. Be aware that the northernmost space in this row does not meet the minimum 9' x 18' requirement and cannot be counted toward meeting required parking unless its dimensions are revised. This does not appear to be an issue, because it appears that space was not counted based on staff accounting of all parking proposed. 2°d submittal: Comment addressed. d. Revise the amount of handicap parking spaces provided in the note on Sheet 1. The plan shows 14 handicap spaces provided, not 12 as currently stated. 2°" submittal: Comment addressed. 2. [32.7.8 and 4.171 The Lighting Plan on Sheet 26 must be revised to comply with all application regulations contained in Section 4.17. Please address the following: a. [4.17.4 (b)(1)] Provide a photometric plan that identifies footcandle measurements across the property and along all property boundaries. Footcandle measurement spillover cannot exceed 0.5 footcandles onto public roads or adjacent properties zoned RA. Show all proposed light locations and identify different lamp types with unique symbology. 2°" Submittal: Comment addressed. b. [4.17] Provide a luminaire schedule identifying outdoor lighting type, manufacture/model number, quantity proposed, pole height, lumens, wattage, and light loss factor (LLF) used to calculate the footcandles for each luminaire type. Albemarle County requires lighting plans to use a LLF of 1.0. Include a legend that identifies the symbology used for each luminaire type on the plan. 21 submittal: Comment not fully addressed. The Luminaire Schedule states that a LLF factor Of 0.950 was used to calculate footcandle measurements. Albemarle County requires a LLF factor of 1.0 to be used. Revise the schedule so that it states that the LLF used is 1.0, and revise footcandle measurements as necessary. 31 Submittal: Comment addressed. The Lumens column in the Luminaire Schedule states "N.A" for each lamp type. Provide the lumens for each lamp tvve. 3'" Submittal: Comment addressed. The quantity of luminaire types provided is different in the Site Lighting Fixture Schedule and the Luminaire Schedule. Please revise so that the accurate quantity of each luminaire type is stated in both tables. 31 submittal: Comment not addressed, the quantity of luminaries provided is different in the Site Li¢htina Fixture Schedule and the Luminaire Schedule. Please revise so that the accurate quantity of each luminaire type is stated in both tables. c. [4.17.4 (a)] Highlight sections from the manufacturer cut sheets that identify the lumens/wattage emitted, and confirm that each outdoor luminaire will be equipped with a full -cutoff fixture. 2°d submittal: Comment addressed. d. Revise the lighting plan as necessary to comply with any ARB requirements. 2°d submittal: Comment addressed. 3. [32.6.2 (g), 32.7.4.2, and 32.7.5.3] An Application For Easement Plat will need to be submitted, reviewed, approved, and recorded prior to final site plan approval. The following must be addressed: a. Once the easement plat is approved, all easement labels on the final site plan will need to be revised so they state "existing" and state the deed book/page number for the easement plat and any associated deeds of easement. 2"d submittal: Per applicant comment response letter, all blank easement labels will be revised to state the recorded instrument number once SUB202000089 and SUB202000115 are approved and recorded. Revise the label for TMP 07800-00-00-020M5 so it states the correct acreage and instrument number for TMP 78-20M5 once the BLA/easement plat. SUB202000016. is approved and recorded. 31 Submittal: Once SUB202000089. SUB202000115 and SUB202000130 are recorded, please update the labels for each parcel so that the acreaees and recorded instrument numbers are correct. b. As mentioned in comment # 1 above, a new public access easement will need to be provided on TMPs 07800- 00-00-020M1 and 07800-00-00-020M6 for the entire length of the 10' Class A asphalt path. The owners both properties will need to sign the plat prior to County approval. 2°d submittal: Comment addressed. 4. [32.7.91 Please remove the callout for the primitive trail from Sheet 12. It is the County's understanding that this primitive trail is no longer proposed. 2°" submittal: Comment addressed. 5. [32.7.91 On Sheet 14, please add a column to the Plant Schedule so that is includes the symbology used for each plant type. 2°d submittal: Comment addressed. 6. [32.7.9.4 (b)] The County of Albemarle Conservation Checklist is provided on Sheet 14. However, the landscaping plans do not identify the locations, species, and sizes of existing vegetation that will be retained. Please add this information to the landscaping plans, and provide a table on Sheet 14 identifying the species, sizes, and quantity of each landscaping material that will be retained. Provided a canopy coverage calculation so that staff can verify the overall 15% tree canopy requirement is being met. See comment #8 below for information on how to obtain canopy coverage information, or explain the source used to identify the canopy coverage for existing plants if they are larger than the calipers listed in the Albemarle County Plant Canopy Calculations. 2°d submittal: Comment addressed. 7. [32.7.91 On Sheet 14, please add a column to the Plant Schedule that states the type of landscaping material that each proposed species is categorized as by the Albemarle County Recommended Plants List (i.e. Large Deciduous Tree, Ornamental tree, etc.) 2°d submittal: Comment addressed. 8. [32.7.91 On Sheet 14, please add a column to the Plant Schedule that states the canopy coverage of each landscaping material proposed per plant, and the overall canopy coverage based on the overall quantities of each species provided. Individual plant canopy coverage can be found in the Albemarle County Plant Canopy Calculations. 21 Submittal: Comment not fully addressed. The individual canopy figures given for numerous landscaping species do not match the Albemarle County Plant Canopy Calculations list. This appears to be because the caliper/sizes of materials are larger than required. Staff cannot independently verify that the individual canopy (and therefore, total,) canopy figures for those species are correct. Per comment #10 below, please revise the caliper/size at time of installation to match Ordinance requirements. Please revise the Plant List on Sheet 14 so that the individual and total canopy coverage for the following species match the list. Species with incorrect canopy figures are identified below by the acronym stated in the "Symbol' column on the Plant List: a. Shade trees: AR BN, GB, LSR, LT, OB, OP, and OS. 3" Submittal: Comment not addressed, canopy figures are still incorrect. See attached document for accurate canopy coverage for each species. Please revise the b. attached document for accurate canopy coverage for each species. Please revise the table on Sheet 14 as necessary. c. Screening: UK, ISH, and PT. 31 Submittal: Comment not addressed, canopy figures are still incorrect. See attached document for accurate canopy coverage for each species. Please revise the table on Sheet 14 as necessary, d. Shrubs: IG, IV, IVL, PL, LS. 3'" Submittal: Comment not addressed, canopy figures are still incorrect. See attached document for accurate canopy coverage for each species. Please revise the table on Sheet 14 as necessary, 9. [32.7.91 The landscaping plans on Sheets 12-13 do not show the same quantities of certain plants as specified by the Plant Schedule on Sheet 14. Staff has identified the following inconsistencies that need to be addressed: 2°d submittal: Comment addressed. a. No ISH Satyr Hill Holly plants are shown on Sheets 12-13, but the Plant Schedule says 51 are provided. 2" submittal: Comment addressed. b. No LS Creeping Liriope plants are shown on Sheets 12-13, but the Plant Schedule says 6,532 are provided. 2n1 submittal: Comment addressed. c. 33 AR October Glory Red Maples are shown on Sheets 12-13, but the Plant Schedule says 37 are provided. 20" submittal: Comment addressed. d. 16 IJK Jersey Knight Holly plants are shown on Sheets 12-13, but the Plant Schedule says 17 are provided. 2' submittal: Comment addressed. e. 32 LSR Rotunidiloba Sweetgums are shown on Sheets 12-13, but the Plant Schedule says 29 are provided. 2°" submittal: Comment addressed. f. 34 LT Tulip Poplars are shown on Sheets 12-13, but the Plant Schedule says 43 are provided. 2"d submittal: Comment addressed. g. 12 PT Loblolly Pines are shown on Sheets 12-13, but the Plant Schedule says 17 are provided. 2"d submittal: Comment addressed. h. 5 NT Nuttall Oaks are shown on Sheets 12-13, but the Plant Schedule says 6 are provided. 2"d submittal: Comment addressed. i. 33 QS Shumard Oaks are shown on Sheets 12-13, but the Plant Schedule says 34 are provided. 2"d submittal: Comment addressed. 10. [32.7.9.51 Large shade trees need to be provided along the entire length of the property frontage along Peter Jefferson Parkway. a. [32.7.9.5 (c)] Each tree must be a minimum of 1 '/z caliper at time of installation. 2"d submittal: The OP trees being provided along the frontage are proposed to be installed at 2 %" caliper. Please revise so that these trees are installed at a size between 1 % - 1 %" per Ordinance requirements. Revise the Plant List on Sheet 14 as necessary. 3" Submittal: Comment addressed. b. 132.7.9.5 (d)] Trees shall be spaced evenly at 1 tree per 50' of frontage. 2°" submittal: Comment addressed. c. [32.7.9.5 (e)] Pending ARB review, additional shrubs may need to be located along the property frontage to screen off-street parking. 2°d submittal: Comment addressed. 11. [32.7.9.81 The overall canopy calculation on Sheet 14 is incorrect. According to the Land Area notes on Sheet 1, there is 8.1 acres of area that the 15% calculation should be based from. This means a canopy coverage of 1.26 acres is required. Please revise. 2"d submittal: Please note that the canopy figures for certain landscaping species do not match the Albemarle County Plant Canopy Calculations, as previously mentioned in comment #8 above. Please revise the Plant List on Sheet 14 so that individual and total canopy coverage for each species is correct, and revise the total canopy provided figure as necessary. 31 Submittal: Comment not addressed. Once the canopy figures are adiusted as mentioned in comment #8 above, please update the individual canopy coverage for each species, and the total canopy coverage provided. 12. [32.5.2 (b), 25A.6, 21.7, and 4.20] Please revise the setback note on Sheet 1 so that it states all minimum and maximum setback requirements. No setbacks were established with the proffers/Application Plan ofZMA2001-15. Therefore, the setbacks for conventional commercial districts apply to this property. See Section 4.20 (a) of the Zoning Ordinance. 2"d submittal: Comment not fully addressed. The note does not state all applicable setbacks. They are as follows: a. Front minimum: 10 feet from the right-of-way or the exterior edge of the sidewalk if the sidewalk is outside of the right-of-way: for off-street parking or loadingVaces. 10 feet from M public street right-of-way. 31 submittal: Comment stands, setback note was not revised as previously specified. b. Side and rear minimum: Primary structures shall be constructed and separated in accordance with the current edition of the Building Code. 31 submittal: Comment stands, setback note was not revised as previously specified. 13. [32.5.2 (b), 25A.6, 21.7, and 4.201 Please revise the stepback note on Sheet 1 so that it states: "Front stepback (minimum): For each story that begins above 40 feet in height or for each story above the third story, whichever is less, the minimum stepback shall be 15 feet." 21 submittal: Special Exception for a stepback waiver for building#3 is going to the Board on Julv 15. 2020 for approval. Once annroved_ please update the note so that it states: front stepback requirement waiver for northeast facade of building #3 approved by Albemarle County Board of Supervisors July 15, 2020." 31 Submittal: Please update the stepback note on Sheet 1 so that it states: "front stepback requirement waiver for northeast facade of building #3 approved by Albemarle County Board of Supervisors July 15, 2020." 14. [General Comment] It appears that some sheets do not show the full extent of improvements proposed. For example, proposed landscaping is not visible at the southern portion of the property on Sheet 13. Please amend the drawings so that all proposed improvements are visible across applicable sheets. 2°d submittal: Comment addressed. a. The full extent of the proposed 10' Class A path on TMP 07800-00-00-020M1 should be visible on the layout and grading drawings. 2°d submittal: Comment addressed. 15. [4.7] Per note 1 on Sheet 1, all open space areas inside of the Presidio development are to be privately owned and maintained. On sheets 15-17, please revise the open space labels so they do not say "to be dedicated." This implies they will be dedicated to Albemarle County for public use. 3'd Submittal: Comment addressed. a. On applicable drawings, revise the label for TMP 78-20M5 so that it states it is open space reserved for dedication to Albemarle County. Once SUB202000016 and the other BLA plat mentioned in comment #1 above are recorded, update the property label so that it states the recorded instrument. 3'd submittal: Comment stands. Once all outstanding subdivision applications are approved and recorded. please revise the property labels for TMP 78-20M5 so that it states that the open space is reserved for dedication to Albemarle County and includes the correct recorded instrument numbers. Please contact Cameron Langille at the Department of Community Development at blanig llegalbemarle.org or 296-5832 ext. 3432 for further information. 10 Albemarle County Engineering Services —John Anderson, janderson2galbemarle.org —No objection, see attached. Albemarle County Fire Rescue —Shawn Maddox— smaddox&albemarle.org —No objection, see attached. Albemarle County Department of Parks & Recreation — Tim Padalino, ipadalino@albemarle.org — Requested changes, see attached. Albemarle County Service Authority (ACSA) — Richard Nelson, melson@serviceauthority.org — See attached approval letter. 11 � AI ?"h �IRGINrP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 229024596 Phone (434) 296-5832 Fax (434) 972-4126 Project: Project file number: Plan preparer: Owner or rep.: Applicant: Plan received date: (Rev. 1) (Rev. 2) (Rev. 3) (Rev. 3a /update) Date of comments: (Rev. 1) (Rev. 2) (Rev. 3) (Rev. 3a /update) Reviewer: Project Coordinator: Site Plan review Martha Jefferson Hospital Presidio Apartments - FSP SDP2020-00023 Scott Collins; Collins Engineering [200 Garrett St., Suite K, Charlottesville, VA 22902, scott(a)collins-engineering.coml Presidio Pantops LLC / 455 Second St. SE 5t' Floor Charlottesville, VA 22902 [ alanAriverbenddev.com ] Castle Development Partners LLC / 230 Court Square, Suite 202 Charlottesville, VA 22902 19 Mar 2020 26 May 2020 19 Jun 2020 - digital /dropbox 17 Jul 2020 (retaining wall design); Rev. ESP 4 Aug 2020, link to complete FSP (8/4/2020 2:27 PM) 2 May 2020 6 Jun 2020 25 Jun 2020 23 Jul 2020 -Note: Need complete FSP to complete review 10 Aug 2020 John Anderson - No objection Cameron Langille Note: Given review constraints, Engineering welcomes .PDF preview of revised final site plan andFelated �W9201800027. Preview SIT at this point implies accelerated review er-pfierit3,-review ahead of competing items in review queue/s, if possible. (Rev. 2) Engineering welcomes .PDF preview of Hillis - Carnes' (HC) revised design of the retaining walls. (Rev. 3) Engineering requests link to complete 7/23/20 FSP, and requests that the current FSP display actual revision date, which may be later than 30-Jun 2020. (Rev. 3a) With link to complete FSP, comparison with Hillis -Carnes retaining wall (RW) design possible (PE -seal date 7/10/20). Prior review comments addressed. See pg. 12 for sample comparison of HC RW design with FSP. SDP202000023 (Also, SDP2019-00075 comments, which are basis of Engineering Final Site Plan review comments.) PIP - Peter Jefferson Parkway (Ex.) ACDSM -Albemarle County Design Standards Manual Note: Engineering is grateful for Applicant's immediate written response (1/23/2020 10:42 PM), which reflects sincere interest in limiting comments effect on ISP approval. That Collins Engineering (CE) affords chance to revise comments prior to expanding audience is considerate. Comments relating to guardrail along PIP, review errors, are withdrawn. CE coordinated with VDOT on this (and other projects), and reports slopes graded 3:1 or flatter do not require guardrail (grayscale ikethFetlg :.) Discussion with CE may help resolve line work comments. CG-6 (with gutter) for concentrated runoff in parking areas and travelways is the expectation. CG-2 is fine for high side of parking areas. Appleton Way must meet VDOT Road Design Manual and county code requirements (CG-6 on both sides of the travelway). Parking areas must meet county code requirements. Since this is a site plan, requirements listed at 18-4, 18-32, and Ch. 14 apply to various degree. ACDSM applies. Review errs in stating storm pipe grade of 0.50.0.52. and 0.53%, may not be approved. They can be. Albemarle, having revised review to recommend increase in slope (0.60%) may take skeptical stance concerning any pipe at any depth installed at less than county stone pipe min. slope. Initial comment should have recommended conservative design. As -built drawings routinely reveal pipes (designed at 0.50%) installed at <0.50%, which may lead to failure and expense to remedy. 25 comments identified objectionable are highlighted red. A portion are withdrawn (grayscale/^�-"�..,, ed o"---e :), a portion maybe revised after discussion. Comment 4 is withdrawn provided Engineering Review Comments Page 2 of 12 the ISP plan explicitly states topographic survey performed in support of design meets state code requirements for surveys; otherwise, Albemarle has insufficient information at this point, and cannot assume an aerial survey meets state code. Given this, no comment imperils initial site plan approval from Engineering perspective. Comment #4 has been discussed internally, and Engineering anticipates written response from a licensed surveyor. Engineering is appreciative of thoughtful Applicant response. Misplaced review comments place a burden on Applicants that we hope to avoid. Review errors relate to: guardrail along PIP, inadequate research of suitability of HDPE pipe (permissible to use), and to possible misunderstandings. We regret mistakes. In one day, CE revised ISP in response to comments. Albemarle commends remarkable response. Engineering has not reviewed revisions, but revisions address many comments, now shown in light grayscale. (These will be checked with plan re -submittal.) * Comments relating to guardrail (PJP), prompted by safety concerns, are withdrawn. Request for guardrail along the entire west side of Appleton Street (design relies on retaining walls and slopes steeper than 3:1 above unrecoverable slopes), addressed. Sheet 1-A 1. Recommend revise site plan title to include SDP201900075, Initial Site Plan (FSP) As follow-up: Recommend include SDP202000023 in final site plan, plan title. (Rev. 1) Addressed, 2. Revise SWM Note to include ref. to W0O201800027. Note 1: SWM Facility easement plat is under review. Easement plat recordation required for WPO Plan approval. Note2: SWM Facility Easement widths should be checked against ACDSM, Easement width diagram, ACDSM, p. 15. (Link: https://www.albemarle.org/upload/images/forms center/departments/community development/forms/design standards _manual/Albemarle County Design Standards Manual 2015-04-25 draft.pddf ) 3. Revise Additional Notes: a. (Rev) R.eeenp. le, Notes � and 7, Maieh indicate public stwets (streets in the jovelopment aFe { vat ys). Withdrawn (Clarification to be added to plans.) b. (Rev) Revise Note 6i Drainage easements upstwam of SIVA14 delention eF tFealfflent facil t es Are °SlAr hT facil,ly aFepublie easements,dediioatedto publie use. Withdrawn (Clarification to be added to plans.) c. (Rev) nP;ayidde de 4^n:on nele fe. r cn rr (cur .,.,a rvur so Note 9 may be aluatee^gainst design. Coup.., .,....,. Gig .._ee of 1cn plevation :...,,.eeptable. Withdrawn (ARB purview.) d. Note: Note 2 stating that site travelways will not meet the standards for acceptance into the secondary system of state highways may appear to suggest a standard less than VDOT design for this development. VDOT standards apply to drainage, and to site Travelway A /Appleton Street pavement (depth) sections, entrance geometry, and FC-FC width, as well as on -street parking (Appleton Street). Ref. ACDSM and Code 18-32.7.2.2.a., 14-4I0.(B.,F.,G.,H.,L). Also, Final Site Plan checklist for plan reviewers, p. 2, Entrances. Also, 14-412.B. (Rev) Note serves as reminder VDOT standards apply to travelway /drainage design (note does not request plan revision). 4. Topo and survey: Aerial survey performed by Virginia Resource Mapping dated January 2006 (with field verification by Collins Engineering, August 2019) is insufficient basis of design. Engineering recommends Applicant contact GIS /Ruth Emerick to discuss this review comment. Note: Ms. Emerick anticipates extended leave in the near future. Until an acceptable source of topography is basis of design, Engineering recommends disapproval of ISP, and resubmittal of ISP with acceptable basis of topographic design. (Rev) Comment revised. Ref. JA email to Applicant January 24, 2020 10:50 AM), also, please see above. Comment 4 is withdrawn once ISP plan explicitly states topographic survey performed in support of design meets state code requirements for surveys, otherwise, Albemarle has insufficient information (at this point) and does not assume that aerial survey meets state code. Given this, no comment imperils initial site plan approval from Engineering perspective. Comment 44 was reviewed, internally. Please provide a written certification from licensed surveyor that 2006 aerial survey basis of design meets state survey requirements. (FSP) Partially addressed. Applicant response: `As discussed in the meeting on March 5', Roudabush and Gale have performed additional onsite survey and topography on the site, and have confirmed that the topography is accurate. This additional topo information has been added to the plan sheet and the note on the cover sheet has been updated to reflect this additional information.' Asfollow-uj2: Revise (1A) Topo and Survey Note as requested in lead paragraph, p. 1. Please state that `topographic survey performed in support of design meets state code requirements for surveys.' This was discussed internally, would seem non -objectionable. The site plan is not a plat, does not carry a LS seal, so we restate request for this specific language on the final site plan. Also, please provide date/s of recent survey plats. Recent is non-specific. (Rev. 1) Addressed. Engineering Review Comments Page 3 of 12 5. Revise sheet index to list demolition plan (sheet), retaining wall design, or any other change to plan index. 6. Sheet 2: Existing site elements will be demolished (Ex. gaarAfail /asphalt walk /PJP curb, for example). Provide separate demolition sheet with details of items to be removed (TBR). Please note that Ex. .....,_a_.,May en4, be Femoved to Provide site aeoess. Ex. guaFdFail not Fequired to be remain n t deail�a.� '^ 4. (Rev) Portion of comment relating to guardrail is withdrawn, rest, persists. (FSP) Addressed. Applicant:'_ this portion of the guardrail is being removed per VDOT requirements.' Sheet 3 7_ Label trails 8. Show dthmpsto_. ifa.... Asters aFe .._..yided at each building. (Rev) Withdrawn, dumpsters are not provided at each building. 9. Recommend show sight distance lines at internal travelway intersections on this sheet, they must be shown on sheets 4/5 Ref Code 18412.15.d. For example Appleton St_ and Moraga St.; Appleton and parking ar ind I; Travelway A an(' ppleton and Fisher Street. 10. Evaluate all parking spaces in parking areas for adequate corner clearance with Appleton Street, Ref. Final Site Plan checklist for plan reviewers, p. 3, second item. (Rev) Ref. 18-32.7.2.2: `... Each private street and travelway within a development shall be designed and constructed to the standards for private streets in chapter 14.' 14-412.13. (Private streets serving non-residential, non-agricultural, attached residential, multi- unit residential and combined residential and non-residential uses): `Each private street... shall satisfy Virginia Department of Transportation standards or an alternative standard deemed adequate by the agent, upon the recommendation of the county engineer, to be equivalent to or greater than the applicable standard in the design standards manual, so as to adequately protect the public health, safety or welfare.' ACDSM: page 19 / — standards for private streets in Albemarle County: [ removed w/ FSP comments. ] (FSP) Addressed. Applicant: `As discussed at the March 5' meeting, the parking lot entrances from the main travelways have been updated and reflect the requested turning radii. The location of the parking spaces in conjunction with the intersections have been updated to ensure adequate clearances. The auto turn has also been shown on the plans. In addition, only the requirements of [Ch.] 18 apply to the development and not the requirements from Section 14, which is the subdivision of land. Because no land is being subdivided, there are no private streets, only private travelways.' I I _ Do not show existing Ceatures TBR, existing trail /walk along PJP, Lor example_ This comment applies to a// plan sheets_ 12. Align detectable surface in direction of pedestrian travel. Revise to reflect proper alignment of detectable surface. Show radial detectable surface in radius curves. Revise to remove CG-2 curbing at CG-12 ramps. All line work and site features should accurately reflect design intent. Design should minimize ambiguity. This comment applies to all plan sheets. (Ref. /include CG-12 detail, sheet 10) (Rev) A possible misunderstanding' not a request to remove tie-in (CG-2 or CG-6 to CG-12' transition understood). Just do not want CG-2 /-6 to be shown continuing unbroken across base of CG-12 ramp —regret misunderstanding. (FSP) Partially addressed. As follow-up: Please see sheet 10 VDOT CG-12 detail, lower -left corner of detail, which depicts plan view alignment of detectable surface in a radial curb. Revise layout plan CG-12 wherever inconsistent with VDOT detail (ramps in radial curbs, multiple locations), else contractor may install improperly. Goal is to avoid later tear -out /replacement to meet VDOT CG-12 standard. (Rev. 1) Addressed, 13. Show /label internal stop /yield signs at internal intersections (travelways /parking areas) to establish which thru movement has precedence /right-of-way. Applies to plan sheets 4 and 5, as well. Sheets 4, 5 14. Provide CG-12 wherever asphalt travelway or parking surface runoff is concentrated /conveyed to a storm inlet. Design must provide curb and gutter (18-4.12.15.g). Note recent review comment for 2415 Ivy Road Redevelopment. Waiver, if requested, will likely be disapproved. Ref. 2415 Ivy Road Redevelopment waiver request. Storm conveyance is a priority. Gutter is required by county code, and runoff in parking areas with grade z5% is concentrated. (Note: It appears all inlet capacity and spread calculations include gutter cross -slope, so gutter is assumed in design calculations.) (Rev). Applicant response (1/23/20): `We Engineering Review Comments Page 4 of 12 will provide CG-6 on the curbs that channel water to a drainage structure, but the remaining curb will all be CG-2. This is consistent with the design manual.' Engineering accepts this response. (FSP) Addressed. 15. Eliminate CG-2 at CG-12 ramps. (Rev) Please see item 12, above. (FSP) Withdrawn. 16. Provide and label stop and yield signs. 17. Label site street name/s and stop signs at PIP entrances. 18. Show bumper blocks for parking spaces in front of 5' sidewalks. (FSP) Partially addressed. As follow-up: Several 6' walks appear to need labels, ensure all 6' walks adjacent to 18' L parking spaces are labeled. (Rev. 1) Addressed. 19. Revise labels for any proposed wall with wall ht. >30" to proposed wall with handrail. (FSP) Partially addressed. As follow-up: Revise sheet 5 (elsewhere, if needed) Note specifying handrail for wall ht. > 6'. Handrail is required for retaining wall height >30". (Rev. 1) Addressed. 20. delai1q. Pnqiffe sheets 4 and 5, and sheet 10 pi:wate 4avolway details (width, notes, seetion [asphalt, basol) afe e0H5i5feR4 With Effie and with applieable VDOT- design, ineleding 3,11)OT- feed design and ,damage mantia1_ and VDOT- 2018 pavemeR4 design guide. (Rev.) Withdrawn. Applicant response: `Easement width has been provided over Appleton. Easements are not required on the other travelways in an apartment complex.' Engineering accepts this response. 21. Eliminate CG-2, which does not provide gutter. (Rev) Please see item 14, above. (FSP) Addressed. 22, Provide CG-6, as requested elsewhere. 23. Align detectable surface with direction of pedestrian travel. Provide radial detectable surface detail on this plan view sheet, and provide detail on sheet 10, as requested elsewhere. (FSP) Partially addressed. As follow-up: See item 12, above. (Rev. 1) Addressed. 24. Include ref, to sheet 10 detail for proposed 5' trailway. Sheet 10 includes 5' asphalt pedestrian trail detail, and Class A — Type 1 low maintenance pedestrian pathway detail (both w/ asphalt surfaces), but does not include detail that corresponds with proposed 5' primitive trailway. Note: sheet 4 identifies the same pedestrian facility as both a 5' trailway and a primitive trailway, which differ. Please revise for clarity. 25. Revise 16' L parking spaces fronting 6' walkway width, design is impermissible. Ref. ACDSM, Sec. 7.c.6. (18' L fronting 6' sidewalk is acceptable). 26. Provide Autotum figure (typical passenger vehicle). Eliminate any travel width issues with revised design: a. 12' R entrance, travelway B onto Moraga Street (N intersection), (FSP) Not addressed. Provide auto turn at this location (sheet 4). (Rev. 1) Addressed. b. Rt. Tom in at 6' R entrance, Appleton into parking areas S of building 1, and 5, (FSP) Addressed. c. Rt. Tom in at 12' R entrance, Appleton onto Fisher Street, (FSP) Addressed. d. Ensure entrance radii are 12.5', minimum, (FSP) Addressed. Minimum design radius =12'. e. Revise any entrance into any parking area or internal travelway that does not meet 14-410.B. Angle of intersection design requirement, which stipulates angle of intersection be not less than eighty (80) degrees. See entrance from Appleton into parking area S of building 1, which is —45 degrees. This entrance does not meet min, entrance radii. Autotum may reveal other issues. (Rev.) Applicant response: `We need to discuss this comment [26.a.-e.] as it seems excessive for a parking lot design in an apartment complex.' Turning movements are less problematic with right angle design, but acute turning movements are required with this design, Engineering must ensure vehicles may pass without collision. Request for Autoturn for turning movements off Appleton are not within a parking lot, but primary site access and are evaluated against VDOT standards. Also, item 10, above. (FSP) Partially addressed. Applicant response: `As discussed at the meeting on March 5'", the auto turns have been added to the plan sheet and graphically shown on sheets 4 and 5. Even though the travelways are not required to be designed to street standards, the radii have been updated based on the auto turns, to ensure safe and adequate travelways through the site.' As follow-up: see item 26.a., above. (Rev. 1) Addressed. 27. . See a:..,.......:on relating to else .lio-e. (Rev) Withdrawn. 28. Do not show portions of Ex. trail along PIP that will be demolished. (Rev). Once Ex. trail across front of development is demolished, it does not need to appear on site plan sheets showing improvements. (May be easier to discuss.) (FSP) Addressed. 29. Label entrances with a VDOT designation (CG-9a, etc.), especially Appleton Street onto internal travelways, or areas mentioned elsewhere. Engineering Review Comments Page 5 of 12 30. Provide travehvay stationing corresponding with sheet 18 and 19 travekvjq profiles_ Additional commenu possihle once stationing shown_ 31. Provide detailed PE -sealed geotechnical retaining wall design (not generic design) for any walls supporting infrastructure; for example: walls west of Appleton Street and tiered retaining walls upslope of wet pond. Ref. Retaining Wall checklist for reviewers. Revise plan set index to accommodate additional plan sheets. (ESP) Not addressed. Applicant response: `As discussed at the meeting on March 5 ", the retaining wall designs will be submitted for a building permit during the building construction aspect of the development. The site plan will be approved, and the approved site plan will be submitted with the building permit application and wall designs.' As follow-up: There is an issue with Applicant response: Unless Applicant can provide contemporaneous meeting notes, Engineering recollection differs. Standard review practice is outlined in published documents that guide review of virtually all projects. Engineering restates request for detailed wall designs. Please ref. Final Site Plan checklist for plan reviewers, last item, p. 1 /attached. Also, Retaining Wall Plan checklist for plan reviewers, attached. Information listed in checklist documents is required prior to Final Site Plan approval. (Rev. 1, D Partially addressed. As follow-YJ2: A comprehensive retaining wall design by Hillis -Carnes (HC) Engineering (cover undated /without professional seal) was submitted. Retaining wall (RW) sheets 2-18 are d. Feb. 7, 2020. Plans include overall (plan view) index, profile for ea. wall, with stationing, and typical details. Profiles for forty (40) proposed site retaining walls: a. Walls: (Rev. 2) Comment persists. Applicant response: `Hillis -Carnes' (HQ design of the retaining walls is being updated to match Collins Engineering's (CE) current plans.' Engineering appreciates this response. (Rev. 3a) Addressed. i. IA— 1H (8 walls), near building 1 /or along Appleton St. ii. 2A — 2E (5 walls), near building 2 iii. 3A — 3H (8 walls), near building 3 iv. 4A-4D (4 walls), near building 4 v. 5A-5F (6 walls), near building 5 vi. 4A-4D (4 walls), near building 6 vii. Wall Pond A, B, C, D, E (5 walls), near pond, Note: Wall 4B is continuous from well N of building 4 to W end of wet pond, L=827.5'. b. As follow-up: i. Revise site plan grading or RW design for consistency. Apparent inconsistencies 1. Wall 4B (Rev. 2) Addressed. Applicant: `On sheet 9, immediately below Moraga Street's station 16+00, retaining wall 4B previously showed an incorrect TW elevation of 427'. Sheet 9 now correctly lists the top of wall elevation as 426'. Also, the HC design incorrectly listed this wall height's maximum height as 8' and it will be corrected.' HC-8 [ Rev. 1 image removed with Rev. 2 comments. ] HC-9 [ Rev. 1 image removed with Rev. 2 comments. ] Final Site Plan, sheet 9 (FSP-9): [ Rev. 1 image removed with Rev. 2 comments. ] 2. Note: all five TWBW labels in image above indicate 7' ht. Compare with Max. height =6' label. Revise for consistency /per ACDSM, 18-30.7.5, as applicable. (Rev. 2) Addressed. Applicant: `On sheet 9, the previous CE plans incorrectly listed a maximum wall height of 6' for Wall Pond A, B, C, D and Wall 4B. Sheet 9 has been revised, in the middle -right portion of the page, to list a maximum wall height of 7' in the vicinity of the wet pond for Wall Pond A, B, C and D. Also, Wall Ponds B, C and D transition to a maximum height of 6' further to the east. Sheet 9 was updated to label this, as well as to provide additional transitional spot shots. Additionally, there is a small 5' horizontal section at the end of Wall Pond A that encroaches into the end of a County defined steep slopes area. The wall in this 5' horizontal section has a maximum wall height (2') that is less than the 6' threshold. Sheet 9 has been updated Engineering Review Comments Page 6 of 12 accordingly. Lastly, in a June 18' phone conversation between Mr. Murray of CE and Mr. Anderson of County Engineering it was confirmed maximum wall heights may exceed 6' outside of steep slopes, but walls within steep slopes must not be greater than 6'. The plans reflect this.' 3. Note: HC-8/-9 and SP-9 elev. differ by —2.5'. Revise for consistency /accuracy. (Rev. 2) Addressed. Applicant: `Sheet 9, in the middle -right portion of the page immediately adjacent to the border, previously listed (incorrectly) the maximum wall height as 7' in this area. The plans have been revised to now read a maximum wall height of 6' in this vicinity. Please also see response above to comment 3 La.' 4. HC-1 is inconsistent with later HC RW design sheets. C,....paw, r _ o. . ple s of 14C 8/ o (above) with 14C ,.oyeF (below) Wall 4B, image belo Note: HC plans appear internally inconsistent and inconsistent with FSP). HC-cover. [ Rev. 1 image removed with Rev. 2 comments. ] (Rev. 2) Addressed. Applicant: `Please see response above to comment 3 La., 5. FSP-9 Wall 4B TW-BW labels inconsistent with HC-cover. Revise for accuracy. (Rev. 2) Addressed. Applicant: `Please see response above to comment 3 La. and 3 Lb.1. The bottom of Wall 4B remains at elevation 420, and the wall has a maximum wall height of 6'.' 6. Transfer HC wall labels to ESP sheets 8, 9. (Rev. 2) Addressed. Applicant: `Sheets 8 & 9 were updated to label the retaining walls.' 7. Pond Wall E (Rev. 2) Addressed. Applicant: `Wall Pond E correctly lists the maximum top of wall elevation as 432' and the bottom of wall elevation as 428'. Please also see response above to comment 3 La.' a. HC-14 /FSP-9 TW labels are consistent (432'). b. HC-cover /FSP-9 TW labels are inconsistent: 434' v. 432' respectively. c. HC-cover /HC-14 TW labels are inconsistent: 434' v.432' respectively. d. HC-1 /FSP-9 BW labels are inconsistent: 429' v. 428', respectively. e. HC-1 /HC-14 BW labels are inconsistent: 429' v. 425', respectively. 8. Wall 4D (Rev. 2) Addressed. Applicant: `Sheet 8 correctly lists the top of wall elevation as 408' and the bottom of wall elevation as 402' for the majority of its run. Sheet 8 was updated and now shows additional spot shots at the beginning and ending transitional lengths for clarity. The maximum retaining wall height when in steep slopes is 6', as shown, in accordance with County requirements. Please also see response above to comment 31.a.' a. HC-cover /FSP-8 TW-BW labels are consistent (408'- 402'). b. HC-10 /FSP-8 TW labels are inconsistent: 406'- 408'. c. HC-cover /HC-10 TW labels are inconsistent: 408' - 406'. d. HC-10 /FSP-8 BW labels are inconsistent: 399' - 402'. e. RW design proposes 7.66' wall on Managed Steep Slopes. Max, ht. =6'. Revise. HC-14 (TW=432.33: BW = 425.33') — Wall Pond E [ Rev. 1 image removed with Rev. 2 comments. ] HC-10 (TW=406.33; BW = 398.67') — Wall 4D, Note: Wall height =7.66' [ Rev. 1 image removed with Rev. 2 comments. ] HC-cover, Wall 4D [ Rev. 1 image removed with Rev. 2 comments. ] FSP-8 [ Rev. 1 image removed with Rev. 2 comments. ] (Rev. 2) Addressed. Applicant: `In the aforementioned June 18`h phone conversation, it was determined labeling the beginning wall stations (0+00) and the end of the walls on Collins Engineering's plans was sufficient to address comment 8.ii since the timing and completion of CE's plans likely will precede the timing and completion of HC's plans. As such, sheets 8 and 9 have been revised to add the following labels to each retaining wall: Sta 0+00 and End. Also, please see response above to comment 3 La.' Engineering Review Comments Page 7 of 12 ii. Provide site plan wall stations to guide inspection and review, at a minimum, label site plan with Hillis -Carnes retaining wall begin (0+00) /end stations. Provide 100' station ticks /labels, or closer spacing. iii. Ensure HC Engineering plans are sealed (P.E. /geotechnical), with seal signed and dated. iv. Additional comments possible. c. Note: i. Elevation departure between retaining wall design and plans should be negligible for ESP approval. (Rev. 2) Addressed. Applicant: `Additional spot shots were added to CE's plans to provide farther clarity. Special attention was also given to the perimeter walls, where elevations along the walls transition more.' ii. Retaining wall plans must be internally consistent and accurate. (Rev. 2) Addressed. Applicant: `(ii and in) Please see the response above to comment 3 La., iii. Retaining wall plans must be consistent with ESP TWBW design elevation labels, tie-in grades, etc. iv. Design includes forty (40) retaining walls, all relevant to site layout, many critical to parking, buildings, etc. (Rev. 2) Addressed. Applicant: `(iv-vii) These comments are acknowledged. CE has provided additional retaining wall spot shots to provide further clarity. Please also see the response above to comment 3 La.' v. All initial (3) comparison checks for consistency revealed issues. vi. Given multiple review issues with each of first 3 of 40 retaining wall comparisons, review is suspended pending Applicant revision of grading, ESP, HC RW designs, across all sheets (with care /adequate QC) to resolve Max. height, labeling, grading, cross -plan, and internal design inconsistencies and inaccuracies. vii. Given scope of change, follow-up Engineering ESP review may not be immediate. 32. Provide oil -site CG-12 receiving ramp on the N side of PJP, for ramp on south side of PJP_ 33. Show site entrance lane striping for turn lanes located on PJP. 34, At S end of Travelway B, revise CG-2 at small island at extreme S end of parking E of building 3 to roll- top curb; otherwise, CG-2 may not endure_ 35. In same general location, extend and label GR-2 to protect 6 additional parking spaces which face south (4) or east (2) located upslope of retaining walls (and not currently afforded guardrail barrier protection). (Rev.) 3:1 slopes above a retaining wall require guardrail. Albemarle required guardrail for a separate site plan with flat slope with curb facing a retaining wall in 2019 (Oak Hill Convenience Store). (FSP) Partially addressed. As follow-up: Please provide VDOT GR-2 (guardrail) for 11 radial parking spaces shown on sheet 8 (northernmost section of Travelway B parking lot). (Rev. 1) Addressed. 36. Provide drainage (ditch, etc., with adequate velocity dissipation at end of ditch line) for Driveway Access, Note: Driveway access appears to be Ex. gravel road to be removed (TBR) on sheet 2. Please clarify. (Rev) It may be easier to discuss, please schedule a meeting. (FSP) Withdrawn. Applicant response: `As discussed in the meeting on March 5'", the driveway will have a cross slope and will not collect or create [a] ditch to channel the runoff. The runoff will pass over the roadway, therefore, no ditch or outfall design is necessary.' Sheets 6, 7 37. Label all proposed private yard drain inlets. All inlets that appear in calc. tables (sheets 15, 24) must be labeled in plan view. Also, provide storm profiles for all drainage, including roof leader and yard grate systems. Display graphically with INV information, each point where Nyloplast roof /yard pipes enter structures. Show in drainage profiles. Label these storm conveyance elements (sheets 16, 17). Note: Please see review recommendation or request for design revision relating to allowable storm pipe material type, or system type, specifically relating to depth of fill (-30' in certain locations), listed elsewhere. (Rev) Applicant response: `We have never been required to provide profiles for yard drains and roof leaders. This comment is excessive and needs to be removed. We will provide a drainage schedule for these inlets and roof leaders, but will not provide profiles.' Please ref Drainage Plan Checklist (p. 1-2) Drainage prot➢es: (applicable to site plans, road and drainage plans) [14-311, 18-32] drainage profiles for each pipe, structure or channel must contain: existing ground proposed ground any channel linings Engineering Review Comments Page 8 of 12 all utility crossings a VDOT designation (MH-1, DI-3B, etc.) for each structure throat length for each drop inlet grate type for each grate inlet a label on each structure to correspond with the computations material and strength class or gage of each pipe manhole access every 300' for 15"-42" or 800' for 48" or greater pipe slopes at 0.5% min. to 16% max. (per VDOT studs for anchors over 16%) concrete inlet shaping (IS-1) specified on any structure with a 4' or greater drop safety slabs (SL-1) in any structure taller than 12'. top or rim elevation for each structure all invert elevations for each structure (with positive flow drop between inverts). end sections (ES-1) or endwalls (EW-1) on all pipe outlets. Endwalls for culverts 48" or taller scour outlet protection at all outlets, corresponding to computations (Green Brook, OP) Roof leader lines and yard drains are not incidental items with this design, at times they are, but nearly all (save 2) roof /yard grates lead to parking /road DI -pipe system. Roof -yard systems pass beneath retaining walls, and there may be conflicts. Engineering has requested Nyloplast profiles on other projects (Keswick), review proved helpful to design and Applicant. (FSP) Addressed, in this instance. Also, Applicant response: Item 48 below. See Item 48 for important clarification. 38. Wherever roof /yard drain storm conveyance systems pass beneath a retaining wall, show wall in profile view. Provide detail for lintel above these system pipes if deplh of cover beneath retaining wall is minimal. 39. Show and label ACSA utility easements consistent with easement plat under review. 40. Show /label or revise as necessary all private and public drainage easements, consistent with easement plat under review, consistent with Albemarle County Design Standards Manual easement diagram. Also, see item 2. above. 41. Label all easement widths. Ref. ACDSM, p. 15, easement width diagram. (FSP) As follow-up: Please confirm all drainage easement widths have been evaluated against ACDSM, p. 15, easement diagram. (Rev. 1) Addressed. Applicant: `Easement width chart has been included on Sheet 8 — Grading & Drainage Plan.' 42. Revise especially public drainage easement width at north corner of building 6, since depth to pipe trench floor of this 24` DIA pipe is — 18-11. No portion of any building may occupy any portion of a drainage easement. 43. Pipe 77 is in public easement and may not pass beneath a retaining wall Relocate pipe 77_ 44. Avoid roof /yard drain system pipe location beneath SWM retaining wall at the E end of the wet pond, conflict may be avoided by shifting pipe location —5'. (FSP) Addressed. Applicant response: `All the roof drain and storm pipe conflicts with the retaining walls have been removed. None of the pipes cross under the walls.' Sheets 8, 9 45. Label building 3. 46, Note: Roof /yard storm pipes enter structure numbers 24, 30, 64, 68, 2, 8, and 72. Show graphically, in profile view (sheets 16, 17). Include INV elevations requested elsewhere. 47. In parking west of building 4, provide grade (%) for surface runoff to Sir_ 20 to ensure positive drainage. 48. Label all roof /yard system inlets. Propose grading to ensure surface runoff reaches yard system inlets by proposing grade or providing spot elevations (grate INV) lower than adjacent grade. (FSP) Applicant response: `All the roof drains have been labeled on the plans, as requested. The elevation of the tie-in connections to the storm sewer manhole have been shown on the profiles. Inverts have been added to the yard drain system. Per the recent engineering's determination of roof drains, profile designs are not required for roof drains 8" in size or smaller.' As follow-up: Provide recent engineering determination, else do not rely on this response to request for design information for roof drains or yard inlet /pipe systems. Reviewer is unaware of this determination. If discussed March 5'", please share recollection. Engineering encountered yard /pipe installation issues on a recent project that may require developer to replace sections of pipe (prior to bond release). Reviewer is unaware of recent determination that would exempt a portion (in this case, critical portion) of drainage system from drainage review, or drainage design requirements. Notwithstanding recollections which may differ, Engineering does not request additional information /design revision in context of this review comment, for this project. Engineering Review Comments Page 9 of 12 49. Provide sealed engineering certification from Mfr. that Nyloplast® system elements meet VDOT drainage design specifications (equivalent load, deflection, strength rating, etc.). Settling is a major concern with design that proposes fill approaching 30' with entire pipe runs well above undisturbed ground, placed completely in fill. (Rev) Comment requests professional engineer's certification that a proposed material substitute for a VDOT standard be submitted. If there is settling in significant fill sections and pipe systems deflect or fail, review may be faulted for not requesting material certification of equivalent strength, resilience, etc. of proposed substitute to a VDOT reference standard (FSP) Withdrawn. Applicant response: `As discussed in the March 5' meeting, the storm pipe and plastic Nyloplast design is in accordance with the specifications and requirements.' 50. Show GR-2 along PIP (comment applies to other sheets, as well). Ensure GR-2 end treatments are shown, and labeled. Provide all relevant VDOT guardrail std. details (sheet 10).(FSP) Withdrawn. 51. Add additional existing contour labels N of PIP. (FSP) Addressed. 52. Revise proposed VDOT std allows 3.1 f ;.de W extend to the edge of PiP(Rev) Withdrawn. Guardrail removed along Peter Jefferson Parkway need not be removed. 53. Opposite Travelway A, north of PIP, eliminate asphalt walk line -work at entrance to MJH, since path does not exist beyond curbed limits of entrance to hospital. (Rev) It may be easier to discuss (during meeting). (FSP) Withdrawn. Review error. 54. Guardrail is required along the entire west side of Appleton Street, from PIP to entrance to SWM facility access, given unrecoverable slope beyond curb. Provide /label guardrail. 55. N of building 1, arrows indicate surface runoff, but proposed grading does not match direction of runoff. Provide grading that ensures runoff from slope between PIP and building 1 does not reach building 1, but is conveyed via swale to yard grate inlet/s on the N side of building 1. (FSP) Addressed. Applicant response: `The arrows north of Building # 1 are correct, there is positive drainage away from the building and positive drainage down the slope of the hill. These intersect to drain into the yard inlets, as shown.' 56. At wet pond, revise design to ensure pipe is aligned with riprap; otherwise, wet pond slope will erode. That is, direction of flow cannot change once it exits pipe. Ensure riprap and last pipe section align. Additional MH /pipe section may be required. Revise WPO201800027 to reflect change to site plan. Revise easement plat to reflect change to private drainage easement. 57. At both surface SWM facilities, provide L x W dimensions for riprap at pipe discharge to SWM facilities. 58. Reverse direction of 3:1 slope arrow, S of building 6. (Rev) Minor, slight revision. (FSP) Withdrawn. Review error. 59. Label 2:1 slopes W of Appleton Street near entrance to parking S of building 5. Provide note that these slopes will be planted with ground cover that does not require mowing (species hardier than grass. Note may ref WP0201800027). (FSP) Addressed. `Seeded meadow' mix to be used. See landscape plan. 60. Confirm Easement width is sufficient for proposed UG detention system depth, per ACDSM Easement diagram (Also, see item 2). Revise SWM facility easement plat (under review), if necessary. (FSP) Applicant response. `The underground detention pipes have been deleted from the plan design and are no longer needed.' As ollow-up: please see email to Collins Engineering, 5/2/2020 9:16 AM. (Rev. 1) Comment NA. VSMP /WPO201800027 Amendment 1 is approved (6/5/20). 61. Relocate proposed UG detention system access out of parking space. Revise WPO via letter to file, and w/ .PDF of plan sheet showing change to the WPO Plan. WPO Plan Amendment is not required for this change, alone. (FSP) Applicant response, `The underground detention pipes have been deleted from the plan design and are no longer needed.' As follow-up: please see email to Collins Engineering, 5/2/2020 9:16 AM. (Rev. 1) Comment NA. UG detention removed from design. 62. Label structure #53 (pipe), and #54 (inlet). (FSP) Not addressed. Comment persists. (Rev. 1) Addressed. 63. Reviseproposed retaining wall/s labels to include reference to handrail (`with handrail'). Virtually every retaining wall requires handrail 64. Label preserved steep slopes. 65. Continue driveway access line -work. Indicate limits of project relative to driveway access construction (i.e., tie to existing gravel road /drive. Avoid downslope conflicts)_ 66. If geogrid is needed for retaining walls, ensure tiered walls work with geogrid design. Avoid conflicts (landscaping /storm conveyance). (FSP) Persists to a degree. Also. item 31, above. Detailed retaining wall plan designs required. Applicant response: `The geogrid will not be in conflict with the landscaping and storm sewer. The geogrid will only extend 6' from the walls and will be outside of the pipes and structures. The geo-grid can be cut and molded around any of the storm sewer structures, as necessary.' Engineering Review Comments Page 10 of 12 (Rev. 1) Additional retaining wall comments possible. Please see item 31, above. (Rev. 2) Persists. Addressed pending review of pending revised HC Engineering revised retaining wall design plans. Applicant: `Please see the response above to comment 3 La.' (Rev. 3a) Addressed. Sheet 10 67_ Provide the following and additional relevant details: a. GR-2, b. CG-12," c. Roll Lace curb, d. Dumpster pad, e. Primitive trail, f Nyloplast details, (FSP) Comment persists. Please provide Nyloplast ® details. (Rev. 1) Persists. Also, see item 74, below. (Rev. 2) Addressed. Applicant response: `Sheet 11, in the middle left portion of the page, shows a standard detail for Nyloplast Drain Basins (yard inlets). Per note 41 in the lower left portion of this detail, this design applies to grate inlets ranging from 12"-30" and is applicable to this project. Additionally, sheet 17 was updated to include `installation requirements for ADS Yard/Roof drain system'. In the June 18' phone conversation, it was determined adding these notes to sheet 17 for the private/smaller roof and yard drains exceed the requirements to address this comment. g. Drive Access section, (FSP) Comment persists. See Driveway Access, lower edge sheet 5. (Rev. 1) Partially addressed. As follow-up: Confirm driveway access to receive: 2" SM-9.5 surface course, 3" BM-25 intermediate course, 5" 21-A base course (stone). This may be unintentional. (Rev. 2) Addressed. Applicant response: `The two asphalt paving details in question, located on sheet 10 in the center portion of the page, were combined and are no longer redundant. The consolidated detail now reads `main travelways' and `drive aisles'. The 2"/3"/5" layers are correctly shown.' h. Pipe lintel detail (at walls), (FSP) Withdrawn. Design revised, pipes no longer pass beneath retaining walls. i. Pavement section based on ADT, j_ Reconcile ions with plan view. Note, for example 7' on -street parking width is<9'min _required _ Rel_18-4.12.16.c.2. k. Ensure typical travelway sections are accurate, and match sheets 4, S. Revise typical travelway sections to show CG-6 rather than CG-2 (18-4.12_ IS.g_)_ 1. Please ref. VDOT Road Design Manual B(1)-7 Table 1, Min. travel width, parking 1-side. * Also: CG-12 detectable surface with radial curb. (FSP) Persists at Item 12. As follow-up: Revise CG-12 in layout views to reflect VDOT Std, for detectable surface in radial curb section. (Rev. 1) Addressed. 68. Sheet 11: Provide VDOT pipe bedding std. details. Sheets 12, 13: 69. Show /label intersection sight lines on these plan sheets, all travelway intersections (18-4.12.15.d). Avoid landscape/sight line conflicts. (FSP) Partially addressed. Applicant response: `The intersection sight distances have been shown on the layout sheet and landscaping sheet, as requested. The note about the pruning of the landscaping has been added to the sheet.' As follow-up: Please show sight distance lines on Landscaping Plan, sheet 12. (Rev. 1) Addressed. 70. Avoid landscape canopy species (extensive root systems) - storm system conflicts (Str.# /location), at: a. Str. #64, 24, 60B, U, (FSP) Partially addressed. Conflict persists at Str. 64, 6013; resolved at 24. No structure 88. (Rev. 1) Addressed. b. relocate /remove 3 canopy trees directly opposite Moraga St. entrance, (FSP) Partially addressed. Partial conflict persists. (Rev. 1) Addressed. c. roof /yard system E of building 3 label and W of building 4 label (canopy trees coincident with Nyloplast proposed pipe location), and N of N comer of clubhouse, (FSP) Partially addressed. Conflict persists W of building 4 label. (Rev. 1) Addressed. d. roof /yard system E of building 3, —1/3 building length N of SE comer of building, e. remove trees from SV Engineering Review Comments Page 11 of 12 Sheets 16, 17 71. Recommend Avoid proposed pipe grade < 0.6%. Pipe cannot be removed /replaced with this design without prohibitive expense. Design of 0.50, 0.52, 0.53% cannot -be approved, but invites risk. This design imperils CO unless any deficiency of pipe installation (slope, elevation, deformation, deflection) can be and is addressed. (Rev) Revised to a recommendation. See pg. L, above. (FSP) Applicant response: `Comment removed, pipes may be installed per the engineering minimum which is 0.5%' Design does not reflect Engineering recommendation to increase slope slightly to provide tolerance for error of construction. 72. WgUOSt ...00'iRg With l4HgiROO^^^'^ di8GW,^ rRev) Withdrawn. Up to 16' cover permissible with PE, 24" DIA pipe. Design at UG SWM — Outfall, pipe 77, Sta. 1+00 approaches max. depth, but is acceptable. [ Rev. I image removed with Rev. 2 comments. ] 73. _RoL-a. Limits will apply. HDPE impefils design sinee it may defeFfn, eellapse, efe., while RG12will . Rev) Applicant response: `This comment needs to be removed. This is not accurate and the system is a private drainage system.' Withdrawn /review error. See item 72. 74. HDPE Note references detail. sheet 17. No HDPE pipe bedding detail is provided on sheet 17. (FSP) Comment persists. (Rev. 1) Not addressed. Applicant: `Sheet reference updated to Sheet 11, where bedding detail is located.' Nyloplast ® Inserta-Tee ® detail does not indicate stone bedding depth, compaction, minimum cover requirements, etc, in any detail. (Rev. 2) Withdrawn /review error. Detail provided but overlooked. 75. Provide HDPE pipe bedding detail, (FSP) Comment persists. Please provide ref to sheet with this detail. (Rev. 1) Not addressed. Also, item 74. (Rev. 2) Withdrawn /error. Detail provided but overlooked. 76. Revise profiles per comments, elsewhere (yard/roof system INV, provide roof /yard system profiles, etc.) (Rev) Please see item 37, above. (FSP) Withdrawn. Note (future reference): Important clarification at Item 48, above. 77. Provide and label Y:" steel plate for stepped vertical drops within MHs. Ref. VDOT Drainage Manual, 9.4.8.7 (p. 9-37). Label each MH str. that require a Y:" steel plate floor. (FSP) Comment persists. For example: see sheet 17, Str. 62 and 46. (Rev. 1) Addressed. 78. Label retaining walls in storm profiles. (FSP) Applicant response: `All wall crossings with the storm sewer have been removed.' 79. Ensure retaining wall design works with proximate storm elements (MIL for example). (FSP) Comment persists. Also, Item 31, above. Applicant response: `The comment is acknowledged. The wall design will take into account all existing and proposed infrastructure.' (Rev. 1) Persists. Applicant: `Acknowledged.' (Rev. 2) Persists. Applicant: `The wall design will take into account all existing and proposed infrastructure. Please see the response above to comment 3 La.' (Rev. 3a) Addressed. 80. Specify geotechnical reports of daily inspection of pipe /DI installation operations in fill sections with more than minimal fill beneath storm elements, i.e., for pipe runs installed over significant fill (Str-24 — Str-6, for example). Propose daily inspection with qualified geotechnical reports to be submitted to Albemarle County for verification of backfill (% moisture, content /contamination, compaction, dry density, etc.) (FSP): Comment persists. Please indicate where highlight items (geotechnical specifications /inspection /reporting Notes) occur on plans. Applicant response: `This comment is acknowledged.' As ollow-up: Engineering requests Notes on sheets 16, 17 (similar to ACSA General Water and Sewer Conditions, sheet that reflect request for highlight information (to appear on plans). (Rev. 1) Addressed. 81. Sheet 19: Ensure Fisher Street profile is smooth, VC at each grade transition. (FSP) Comment appears to persist; see Sta. 11+70 (f), Fisher Street. (Rev. 1) Addressed. 82. Sheet 22: Provide sight distance (right) at Int. Appleton Street and PJP. (FSP) Not addressed. Provide sight distance (right) at Int. Arguello Street and PIP. (Rev. 1) Withdrawn. Review error. Applicant: `The median along Peter Jefferson Parkway blocks traffic leaving via Arguello Street from taking a left turn. This is a right-in/right-out entrance, therefore, sight distances aren't needed for a left turn out of the entrance.' Sheets 23, 24 83. Label all design tables (LD-204, LD-229, etc.). Use VDOT designations /ref drainage manual. Engineering Review Comments Page 12 of 12 84. Provide design calculations for Nyloplast roof /yard systems. (FSP) Partially addressed. As ollow-up: Table 9, sheet 24, does not appear to provide pipe capacity. Revise table to provide pipe capacity for all listed drainage pipes. (Rev. 1) Addressed. Ref. sheet 24. 85.pecommendogwm«*-rr,Ioplast (g) s�-,otem r�. 0.37 A, PA rvn i re (Rev) A recommendation, (FSP) As follow-up: See request for capacities of pipes in Table 9 (Item 84). Applicant response: `The nyloplast is adequate to handle this area.' Additional comments possible, once table revised. (Rev. 1) As follow-up: Please revise structure type, YD-1C, so that all 4 descriptions reference 24". (Rev. 2) Addressed. 86. New: Review and respond to FSP- /WPO-related email sent to Collins Engineering, 5/2/2020 9:16 AM. Also, see CE response, email received 5/2/2020 10:56 AM. (Rev. 1) Withdrawn, WPO201800027 Amendment 1 was approved 5 Jun 2020. 87. New: Orient sheets to landscape (rotate counterclockwise, as needed), to aid review (sheets 5B, 12A, 15, 22, etc.). (Rev. 2) Withdrawn per discussion 18-Jun (telecon). Please feel free to call if any questions: 434.296-5832-x3069. Thank you SDP2020-00023 Martha Jefferson Hospital Presidio Apts-FSP 081020rev3a Sample: HC RW (020720 Retaining Wall plan) v. FSP (vi 8/420 link); minor inconsistencies (circled, blue) visible in 2/7/20 HC RW plan v. FSP are resolved with 7/920 HC RW print plan (PE -seal date 7/1020). Engineering has No objection to the ESP. Cameron Langille From: Cameron Langille Sent: Tuesday, July 21, 2020 12:59 PM To: Shawn Maddox Subject: RE: SDP202000023 Presidio Apartments at Martha Jefferson Hospital - 2nd Submittal Final Site Plan Thanks Shawn, I'll update Countyview. From: Shawn Maddox <smaddox@albemarle.org> Sent: Tuesday, July 21, 2020 12:18 PM To: Cameron Langille <blangille@albemarle.org> Subject: RE: SDP202000023 Presidio Apartments at Martha Jefferson Hospital - 2nd Submittal Final Site Plan Cameron — I've reviewed their submissions, will you change the comments in CV to no objection for fire rescue? Thank you, Shawn JUNEE U ALMEMARLE OVLAW" Shawn N. Maddox, CFO, EFO Deputy Fire Marshal Office: 434-296-5833 Cell: 434-326-2623 From: Cameron Langille <blangille@albemarle.org> Sent: Wednesday, July 15, 2020 5:36 PM To: Shawn Maddox <smaddox@albemarle.org> Subject: FW: SDP202000023 Presidio Apartments at Martha Jefferson Hospital - 2nd Submittal Final Site Plan Hi Shawn, Once you're back in the office, would you mind giving me a status update for Fire Rescue review of this site plan? Thanks, Cameron From: Cameron Langille Sent: Tuesday, May 26, 2020 4:10 PM To: John Anderson <0anderson2@albemarle.org>; Margaret Maliszewski <MMaliszewski@albemarle.org>; Shawn Maddox <smaddox@albemarle.org>; Michael Dellinger <mdellinger@albemarle.org>; Brian Becker <bbecker@albemarle.org>; Tim Padalino <tpadalino@albemarle.org>; Richard Nelson <rnelson@serviceauthority.org> Subject: SDP202000023 Presidio Apartments at Martha Jefferson Hospital - 2nd Submittal Final Site Plan Good afternoon, This final site plan has been res-submitted for review. Documents from the resubmittal have been uploaded to County View, and their titles are in the system as follows: • Applicant comment response letter— "SDP202000023 Correspondence 2020-05-11" • Revised final site plan—"SDP202000023 Plan - Revision Final Site Plan and Comps. 2020-05-11" • Fire truck auto turn exhibit — "SDP202000023 Plan - Other (not approved) 2020-05-20 (2)" • Retaining wall design plans— "SDP202000023 Architectural Drawings Final Site Plan and Comps. 2020-05-22" • Recreational amenity substitution request— "SDP202000023 Request of Modification, Variance, Waiver 2020- 05-14" You can access these materials through the following link: https:Hlfwe b.a I bema rle.org/webl i n k/sea rch.aspx?d bid=3&sea rchcom ma nd=%7b%5 bCDD- P la nni ne%5d:%5 bAppl icatio n N um ber%5d=%22SDP202000023%22%7d I have entered all of you names as reviewers in County View. Please send me your comments or enter them into County View by Tuesday, June 16". Please let me know if you have any questions. Thanks, Cameron Cameron Langille I Senior Planner Community Development Department Planning Division blaneille@albemarle.org (434) 296-5832 ext. 3432 Cameron Langille From: Tim Padalino Sent: Friday, August 7, 2020 11:49 AM To: Cameron Langille Subject: Planning Application Review for SDP202000023 MJH PRESIDIO APARTMENTS. The Review for the following application has been completed: Application Number = SDP202000023 Reviewer = Tim Padalino Review Status = No Objection Completed Date = 08/07/2020 No objection. Previous Parks & Rec review comments (# LA and #1.B, dated 6/26/2020) have been addressed on this revised final site plan and/or are otherwise being addressed through associated BLA plat SUB202000130. Thank you for these efforts to provide public access along PJP ROW, through a portion of the Presidio site, through Worrell property, and to the Rivanna Greenway on Albemarle County property. This email was sent from County View Production. Cameron Langille From: Scott Collins <scott@collins-engineering.com> Sent: Thursday, July 23, 2020 10:40 AM To: Jeremy Lynn Cc: Adam Long; Cameron Langille Subject: RE: MJH Presidio Apartments CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Thanks Jeremy! Adam, can you send the link over to Jeremy. Scott From: Jeremy Lynn <jlynn@serviceauthority.org> Sent: Thursday, July 23, 2020 9:59 AM To: Scott Collins <scott@collins-engineering.com> Cc: Adam Long <adam@collins-engineering.com>; Cameron Langille (blangille@albemarle.org) <blangille@albemarle.org> Subject: MJH Presidio Apartments Scott, I'm recommended approval of these plans. Can you send me a link to download the electronic documents for our records? Jeremy M. Lynn, P.E. Senior Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434)977-4511 LAcl]g Water W.,_.. , PLANT CANOPY CALCULATIONS LARGE DECIDUOUS TREES (50'-70) (Shade and/or Street) Botanical Name Common Name rmmum a�peror Height tat Planting m over 10 Years ote t /n 10 Years atroo to Height ote /n f0 Years Area of Canopy (Min. Cal-") (x) (Y) X+Y=T (R) (R) T=D (D)"2'3.14/4= Acer nigrum & cvs. Black Maple (11A" -1%" Cal.) 10 12 22 0.66 14.52 166 Acer rubrum & cvs. Red (Swamp) Maple (Oct. Glory, Red Sunset) (1'S4" -1%" Cal.) 10 20 30 0.75 22.5 397 Acer rubrum "Armstrong" "Armstrong" Red Maple (11/2" -1%" Cal.) 10 20 30 0.25 7.5 44 Acer saccharum & cvs. Sugar Maple (Bonfire, Commemoration, Green Mountain, Legacy) (11/2" -1%" Cal.) 11, 10 21 0.75 15.75 195 Acer x freemanii "Jeffersred" Autumn Blaze Maple (11/2" -1%" Cal.) 10 20 30 0.75 22.5 397 Aesculus hippocastanum Common Horsechestnut (11/2" -1%" Cal.) 12 16 28 0.90 25.2 499 Betula nigra "Heritage" "Heritage" River Birch (10'-12' ht.; 10 15 25 0.90 22.5 397 Carya glabra Pignut Hickory (134" - 131" Cal.) 11 5 16 0.55 8.8 61 Carya ovate Shagbark Hickory (134" - 131" Cal.) 11 5 16 0.60 9.6 72 Celtis x occidentalis & cvs. Hackberry (Magnifica, Prairie Pride) (11/2" -1%" Cal.) 10 20 30 0.90 27 572 Diospyros virginiana Persimmon (11/2"-1%"Cal.) 11 8 18.5 0.75 13.875 151 Fagus grandifolia American Beech (11/2" -1%" Cal.) 10 10 20 0.85 17 227 Fagus sylvatica & cvs. European Beech (11/2" -1%" Cal.) 10 10 20 0.75 15 177 Fraxinus americans & cvs. White Ash (Autumn Purple) (11W -1%" Cal.) 12 151 271 0.75 20.251 322 Fraxinus americana "Rosehill" "Rosehill" White Ash (11W -1%" Cal.) 12 15 27 0.50 13.5 143 Fraxinus americans "Greenspire" "Greenspire" White Ash (11W -1%" Cal.) 12 15 27 0.25 6.75 36 Fraxinus pennsylvanica & cvs. Green Ash (Newport, Patmore, Summit, Urbanite) (11W -1%" Cal.) 12 25 37 0.75 27.75 604 Ginkgo biloba "Magyar" "Magyar" Ginkgo (11W -1%" Cal.) 11 10 21 0.50 10.5 87 Ginkgo biloba "Princeton Sentry" "Princeton Sentry" Ginkgo (11W -1%" Cal.) 11 10 21 0.20 4.2 14 Gleditsia triacanthos inermis & cvs. Thornless Honeylocust (11W -1%" Cal.) 11 20 31 0.75 23.25 424 Gymnocladus dioicus & cvs. Kentucky Coffeetree (Crosswicks Male) (11W -1%" Cal.) 10 25 35 0.77 26.95 570 Halesia monticola Mountain Silverbell (11W -1%" Cal.) 10 15 25 0.66 16.5 214 Liquidambar styraciflua Sweetgum (11W -1%" Cal.) 12 15 27 0.66 17.82 249 Liquidambar styraciflua "Rotundiloba" "Rotundiloba" Sweetgum (11W -1%" Cal.) 121 151 27 0.601 16.2 206 Liriodendron tulipifera Tuliptree or Tulip Poplar (11W -1%" Cal.) 12 25 37 0.60 22.2 387 Magnolia acuminata Cucumbertree Magnolia (134"- 1%" Cal.) 10 20 30 0.60 18 254 Metasequoia glyptostroboides Dawn Redwood (10'- 12'ht.) 10 25 35 0.25 8.75 60 Nyssa sylvatica Blackgum Tree (11W -1%" Cal.) 11 8 19 0.66 12.54 123 Platanus x acerifolia & cvs. London Planetree (Bloodgood) (11W -1%" Cal.) 11 18 28.5 0.76 21.66 368 Platanus occidentals American Planetree (Sycamore) (11W -1%" Cal.) 12 35 47 0.85 39.95 1253 Quercus alba White Oak (11W -1%" Cal.) 10 12 22 0.80 17.6 243 Quercus bicolor Swamp White Oak (11W -1%" Cal.) 11 20 31 0.63 19.53 299 Quercus coccinea Scarlet Oak (11W -1%" Cal.) 11 20 31 0.70 21.71 370 Quercus falcate Southern Red Oak (11W -1%" Cal.) ill 201 31 0.75 23.25 424 Quercus imbriraria Shingle Oak (11W -1%" Cal.) 10 10 20 0.66 13.2 137 Quercus palustris Pin Oak (11W -1%" Cal.) 11 20 31 0.70 21.7 370 Quercus palustris "Green Pillar Pin Oak (Green Pillar) (11W -1%" Cal.) 11 20 31 0.20 6.2 30 Quercus phellos Willow Oak (11W -1%" Cal.) 11 20 31 0.70 21.7 370 Quercus prinus Chesnut Oak (11W -1%" Cal.) 10 10 20 0.70 14 154 Quercus robur English Oak (11W -1%" Cal.) 11 20 31 0.66 20.46 329 Quercus robur & cvs. English Oak (Fastigate, Attention!, Skyrocket) (11W -1%" Cal.) 11 10 21 0.20 4.2 14 Quercus rubra Northern Red Oak ("l % -1%" Cal.) 11 20 31 0.75 23.25 424 Quercus shumardi! Shumard Oak (11W -1%" Cal.) 11 20 311 0.66 20.461 329 Salix alba & cvs. Golden Weeping Willow (134" -1%" Cal.) 101 30 40 0.85 34 907 Taxodium distichum & cvs. Bald Cypress (Shawnee Brave) (10'- 12'ht.) 10 15 25 0.40 10 79 Tilia americans "Redmond" "Redmond" Linden (11W -1%" Cal.) 11 15 26 0.60 15.6 191 Tilia cordata "Greenspire" "Greenspire" Littleleaf Linden (11W -1%" Cal.) 12 15 27 0.66 17.82 249 Tilia tomentosa "Green Mountain" "Green Mountain" Silver Linden (11W -1%" Cal.) 10 15 25 0.75 18.75 276 Ulmus americana & cvs. American Elm (Princeton, Washington) (11W -1%" Cal.) 10 15 25 0.90 22.5 397 Ulmus pawifolia "Allee" "Allee" Elm (11W -1%" Cal.) 12 15 27 0.80 21.6 366 Zelkova serrate "Green Vase" "Green Vase" Zelkova (1i4" -1%" Cal.) 12 20 32 0.66 21.12 350 Zelkova serrate "Village Green" "Village Green" Zelkova (11W -1%" Cal.) 12 20 32 0.75 24 452 05 February 2003 1 of 11 LD-6 MEDIUM DECIDUOUS TREES (40 -50) Botanical Name Common Name rnrmum arperor Height tef Planting m over 10 Years ote t In 10 Years atroo to Height ote In f0 Years Ala or Canopy (Min. CaL/HL) (x) (Y) X+Y=T (R) (R)T=D (D)-2. 3.1414= cer ru rum ak cvs. Kea maple (Autumn Marne, ow a - . Cal.) Acer saccharum "Goldspire" "Goldspire" Sugar Maple (11W" - M, Cal.) 10 20 30 0.50 15 177 Acer truncatum x platanoides "Keithsform" Norwegian Sunset Maple (1"-1W, Cal.) 8 10 18 0.66 11.88 111 Aesculus camea Red Horsechestnut (1"-1W, Cal.) 8 13 21 0.66 13.86 151 Carpinus betulus European Hornbeam (11/2" -1W Cal.) 10 10 20 0.75 15 177 Celtis laevigata "At Seasons" "All Seasons" Sugar Hackberry (11/2" -1W Cal.) 10 201 30 0.751 22.51 397 Cercidiphyllum japonicum Katsuratree (1"-1W, Cal.) 8 20 28 0.60 16.8 222 Corylus celurna Turkish Filbert (1"-1W, Cal.) 9 18 26.5 0.50 13.25 138 Salix nigra Black Willow 10 30 40 0.75 30 707 Sassafras albidum Common Sassafras (1"-1W, Cal.) 9 15 24 0.66 15.84 197 Sophora japonica "Princeton Upright" "Princeton Upright" Scholartree (1"-1W, Cal.) 8 20 28 0.70 19.6 302 Sophora japonica "Regent" "Regent" Scholartree (1"-1W, Cal.) 8 20 28 0.80 22.4 394 SMALL DECIDUOUS TREES (2040) (Street and/or under utility lines) cer Duergeranurn I n en ape - Acer campestre & cvs. Hedge Maple(Evelyn) (6'- 8' ht.) 7 12 19 0.90 17.1 230 Carpinus betulus "Fastigiate" Pyramidal European Hornbeam (6'-8') 7 10 17 0.55 9.35 69 Carpinus caroliniana American Hornbeam (6'-8') 7 9 16 0.80 12.8 129 Cladrastis kentukea (lutea) & cvs. Yellowwood (Perkin's Pink, Sweelshade) (1"-1W, Cal.) 9 15 24 0.80 19.2 289 Crataegus crusgalli var. inermis Thornless Cockspur Hawthorn (6'-8') 7 10 17 0.90 15.3 184 Crataegus laevigata (oxyacantha) Paul's Scarlet English Hawthorn (6'-8') 7 7 14 0.90 12.6 125 Crataegus phaenopyrum Washington Hawthorn (6'-8') 7 10 17 0.80 13.6 145 Crataegus viridis'Winter King" "Wnter King" Hawthorn (6'-8') 7 10 17 0.90 15.3 184 Koelreuteria paniculata Goldenraintree (6'-8') 7 15 22 1.00 22 380 Maackia amurensis & cvs. "Starburst" Amur Maackia (6'-8') 7 51 12 0.90 10.8 92 Malus baccata'Walters" 'Walters" Siberian Crabapple (6'-8') 7 10 17 0.66 11.22 99 Ostrya virginiana American Hophombeam (6'-8') 7 10 17 0.66 11.22 99 Oxydendrum arboreum Sourwood (6'-7') 7 12 18.66 0.71 13.2486 138 Phellodendron amurense "Shademaster' "Shademaster' Amur Corktree (6'-7') 7 15 22 0.90 19.8 308 Pistacia chinesis Chinese Pistache (6'-7') 7 10 17 0.90 15.3 184 Prunus cerasifera & cvs. Flowering Plum (Kreuter Vesusvius, Thundercloud, Newport) (6'-7') 7 8 15 0.90 13.5 143 Prunus incise x Campanulata "Okame" Flowering Cherry (6'-7') 7 8 15 0.75 11.25 99 Prunus sargentil & cvs. Sargent Cherry (Columnar) (6'-7') 7 10 17 0.75 12.75 128 Prunus serrulata & cvs. IJapanese Flowering Cherry (6'-7') 7 7 14 0.75 10.5 87 Prunus x subhirtella "Accolade" "Accolade" Flowering Higan Cherry (6'-7') 7 7 14 0.66 9.24 67 Prunus yeodensis &cvs. Yoshino Flowering Cherry (Afterglow, Akebono) (6'-7') 7 8 15 0.75 11.25 99 Pyrus calleryana & cvs. I Pear (Aristocrat, Autumn Blaze, Capital, Chanticleer, Redspire) (6'-8') 7 121 19 0.70 13.3 139 Sorbus alnifolia & cvs. I Korean Mountainash (Redbird) (6'-8') 7 81 15 0.60 9 64 05 February 2003 2 of 11 LD-( ORNAMENTAL TREES (20=40) Botanical Name Common Name Minimum Caliperor Height Heightat Planffng Growthmier 10 Years TotalHeight In 10 Yees RatioofLiVft to Heght Tote In f0 Yeen Ala or Canopy (Min. CeL") (x) (Y) X+Y=T (M (R) T=D (D)"2. 3.14/4= Acer griseum Paperbark Maple (6'- 8' ht.) 7 9 16 0.66 10.56 88 Amelanchier canadensis & cvs. Shadblow Serviceberry (White Pillar) (6'-7' ht.; clump) 7 13 19.5 0.66 12.87 130 Amelanchier x grandiflora & cvs Serviceberry (Autumn Brilliance, Robin Hill) (6'-7' ht.; clump) 7 13 19.5 0.66 12.87 130 Amelanchier laevis & cvs. Allegheny Serviceberry (Cumulus, Majestic) (6'-7' ht.; clump) 7 13 19.5 0.66 12.87 130 Betula jacquemontii White -Barked Himalayan Birch (6'-7') 7 15 22 0.60 13.2 137 Betula platyphylla "Whitespire" 'Whitespire' Asian White Birch (6'-7" ht.; Gump) 7 151 221 0.60 13.21 137 Catalpa bignoides Southern Catalpa (6'-8' ht.) 7 15 22 0.90 19.8 308 Cards canadensis & cvs. Eastern Redbud (Alba, Forest Pansy, Oklahoma White, Texas White) (6'-7') 7 10 17 0.74 12.58 124 Comus florida & cvs. Flowering Dogwood (Cherokee Princess & Chief, Cloud Nine, Rubra, (6'-7' ht.) 7 10 17 0.74 12.58 124 Comus kousa & cvs. Kousa Dogwood (Celestial, Constellation, Heart Throb, Rosabella, Summer (6'-7' ht.) 7 8 15 0.85 12.75 128 Comus x (Rutban, Rutcan, Rutdan, Rutgers Series Flowering Dogwood (6'-7' ht.) 7 10 17 0.74 12.58 124 Halesia carolina & cvs. Carolinia Silverbell (Rosea) (6'-8') 7 12 19 0.66 12.54 123 Halesia diptera "Magniflora" Two -Winged Silverbell (6'-8') 7 10 17 0.75 12.75 128 Magnolia grandiflora & cvs. Southern Magnolia (Edith Bogue, Victoria, Little Gem) (6'-8') 7 10 17 0.60 10.2 82 Magnolia x loebneri & cvs. Loebner Magnolia (Ballerina, Leonard Messel, Merrill) (6'-8') 7 8 15 0.70 10.5 87 Magnolia x soulangiana & cvs. Saucer Magnolia (Alexandrina, Jane, Verbanica) (6'-8') 7 101 171 0.80 13.6 145 Parrotia persica Persian Parrotia (6'-8') 7 12 19 0.75 14.251 159 Prunus Corinthian & cvs. Flowering Peach (Mauve, Rose) (6'-8') 7 8 15 0.75 11.25 99 Prunus subhirtella'Autumnalis' Autumn Flowering Higan Cherry (6'-8') 7 8 15 0.66 9.9 77 Prunus subhirtella'Pendula Rosa' Weeping Cherry (6'-8') 7 8 15 0.66 9.9 77 Salix babylonica Babylon Weeping Willow (6'-8') 7 10 17 0.80 13.6 145 Stewartia koreana Korean Stewartia (6'-8') 7 7 14 0.66 9.24 67 Stewartia pseudocamellia Japanese Stewartia (6'-8') 7 8 15 0.66 9.9 77 Syringa reticulate & cvs. I Japanese Tree Lilac (Ivory Silk, Regent) (6'-8') 1 8 10 18 0.75 13.5 143 05 February 2003 3 of 11 LD-6 SMALL ORNAMENTAL TREES (W-20) Botanical Name Common Name Minimum Caliperor Heght Heightat Planting Gmwthmr 10 Years TotalHeight In 10 Years Ratio to Haight ote In f0 Years Ala orCanopy (Min. Cat") (x) (Y) X+Y=T (R) (R) T=D (D)"2.3.1414= Acer ginnala "Flame" "Flame" Amur Maple (6'-7') 6 12 18 0.90 16.2 206 Acer palmatum Japanese Maple (6'-7') 6 10 16 0.90 14.4 163 Acer tataricum Tartadan Maple (6'-7') 6 7 13 0.90 11.7 107 Catalpa bungei Umbrella Catalpa (6'-7') 6 10 16 0.90 14.4 163 Chionanthus retusus Chinese Fdngetree (6'-7') 6 6 12 0.90 10.8 92 Chionanthus virginicus White Fdngetree (6'-7') 6 81 141 0.90 12.61 125 Comus mas Comeliancherry Dogwood (6'-7') 6 10 16 0.75 12 113 Cotinus ceggygria & cvs. Royal Purple Smoketree (6'-7') 6 10 16 0.90 14.4 163 Enkianthus campanulatus Redvein Enkianthus (6'-7') 6 7 13 0.65 8.45 56 Franklinia altamaha Franklinia (6'-7') 6 10 16 0.70 11.2 98 Hamamelis virginiana Common Wtchhazel (6'-7') 6 10 16 0.75 12 113 Laburnum x watered Goldenchain Tree (6'-7') 7 10 17 0.65 11.05 96 Lagerstroemia indica x cvs. Crapemyrtle (6'-7') 6 9 15 0.66 9.9 77 Magnolia liliiflora Magnolia (Ann, Betty, Galaxy, Jane) (6'-7') 6 2 8 0.75 6 28 Magnolia stellata & cvs. Star Magnolia (Royal Star, Watertily) (6'-7') 6 6 12 0.66 7.92 49 Magnolia virginiana Sweet Bay Magnolia (6'-7') 6 101 16 0.75 121 113 Malus floribunda Japanese Flowering Crabapple (6'-7') 6 8 14 0.70 9.8 75 Malus hupehensis & cvs. Tea Crabapple (Cardinal, Strawberry Parfait) (6'-7') 6 10 16 0.80 12.8 129 Malus sargentil Sargent Crabappple (6'-7') 6 2 8 0.90 7.2 41 Malus & cvs. Crabapple (Indian Summer, Narragansett, Pink Spires, Prairiefire, Red Baron, Snowdrift, Sutyzarr) (6'-7') 7 9 16 0.80 12.8 129 Malus transitoria "Schmidtcutleal" "Golden Raindrops" Crabapple (6'-7') 7 8 15 0.75 11.25 99 Malus zumi calocarpa Zumi Crabappple (6'-7') 7 9 16 0.75 12 113 Pyrus fauriei "Westwood" Korean Sun Flowering Pear (6'-7') 6 10 16 0.70 11.2 98 Stewartia ovate Mountain Stewartia (6'-7') 6 10 16 0.75 12 113 Styrax japonica Japanese Snowball (6'-7') 7 8 15 0.73 10.95 94 Viburnum prunifolium Blackhaw Viburnum (6'-7') 7 8 15 0.73 10.95 94 Vibumnum sieboldii Siebold viburnum (6'-7') 6 81 141 0.6ral 9.241 67 05 February 2003 4 of 11 LD-6 BROADLEAVED EVERGREENS (Screening) AND ORNAMENTAL CONIFERS (20'-70) Botanical Name Common Name minimum i7aliperor Height He taf Planting m over 10 Years ote t In 10 Years atroo to Height ote In f0 Years Ala orCenopy (Min. Cal-") (x) (Y) X +Y =T (R) (R) T = D (D)-2.3.1414= Abies concolor White Fir, Concelor Fir (4'-5') 5 10 15 0.50 7.5 44 Cedrus atlantica "Glauca" Blue Atlas Cedar (4'-5') 4.5 10 14.5 0.50 7.25 41 Cedrus deodara Deodar Cedar (4'-5') 4.5 20 24.5 0.55 13.475 143 Cedrus libani Cedar of Lebanon (4'-5') 4.5 10 14.5 0.65 9.425 70 Chamaecyparis lawsoniana Lawson Falsecypress (4'-5') 4.5 20 24.5 0.55 13.475 143 Cryptomeria japonica & cvs. Cryptomeria (Black Dragon, Yoshino, Ben Franklin) (4'-5') 5 201 251 0.50 12.51 123 X Cupressocyparis leylandii Leyland Cypress (4'-5') 4.5 20 24.5 0.22 5.39 23 Cupressus arizonica "Carolina Sapphire" Blue Arizona Cypress (4'-5') 5 10 15 0.50 7.5 44 Ilex opaca & cvs. American Holly (4'-5') 4.5 10 14.5 0.58 8.41 56 Ilex x aquipernyi'San Jose' San Jose Holly (4'-5') 5 10 15 0.63 9.375 69 Ilex x attenuate Tosteri' Foster Holly (4'-5') 4.5 10 14.5 0.31 4.495 16 Ilex x'Nellie R. Stevens' Nellie R. Stevens Holly (4'-5') 2 10 12 0.63 7.5 44 Juniperus virginiana & cvs. Eastern Redcedar (4'-5') 4.5 10 14.5 0.31 4.495 16 Larix decidua Eurpoean Larch (4'-5') 5 20 25 0.40 10 79 Magnolia grandiflora Southern Magnolia (4'-5') 4.5 10 14.5 0.57 8.265 54 Picea abies Norway Spruce (4'-5') 4.5 101 14.51 0.50 7.25 41 Picea glauca White Spruce (4'-5') 4.5 10 14.5 0.30 4.351 15 Picea orientalis Oriental Spruce (4'-5') 5 10 15 0.40 6 28 Picea omorika Serbian Spruce (4'-5') 5 10 15 0.40 6 28 Picea pungens var. glauca Colorado Blue Spruce (4'-5') 4.5 10 14.5 0.30 4.35 15 Pinus bungeana Lacebark Pine (4'-5') 4.5 8 12.5 0.66 8.25 53 Pinus cembra Swiss Stone Pine (4'-5') 4.5 10 14.5 0.50 7.25 41 Pinus densiflora Japanese Red Pine (4'-5') 5 12 17 0.75 12.75 128 Pinus flexilis Limber Pine (4'-5') 4.5 10 14.5 0.50 7.25 41 Pinus parviflora Japanese White Pine (4'-5') 4.5 10 14.5 0.80 11.6 106 Pinus resinosa Red Pine (4'-5') 5 121 171 0.75 12.75 128 Pinus strobus Eastern White Pine (4'-5') 4.5 20 24.5 0.50 12.251 118 Pinus sylvestris Scotch Pine (4'-5') 4.5 12 16.5 0.65 10.725 90 Pinus taeda Loblolly Pine (4'-5') 5 20 25 0.65 16.25 207 Pinus thunbergiana Japanese Black Pine (4'-5') 4.5 11 15 0.90 13.5 143 Taxodium distichum Bald Cypress (4'-5') 5 12 17 0.40 6.8 36 Taxus baccata English Yew (4'-5') 4.5 8 12.5 0.62 7.75 47 Taxus cuspidata "Capitals" Upright Japanese Yew (4'-5') 4.5 8 12.5 0.62 7.75 47 Thuja occidentalis & cvs. Eastern Arborvitae (Emerald, Nigra, Techny) (4'-5') 4.5 10 14.5 0.25 3.625 10 Thuja orientalis & cvs. Oriental Arborvitae (Berckman's, Bonita) (4'-5') 4.5 10 14.5 0.30 4.35 15 Thuja plicata & cvs. I Giant Arborvitae (Atrovirens, Green Giant) (4'-5) 1 4.51 101 14.51 0.20 2.9 7 05 February 2003 5 of 11 LD-6 BROADLEAVED EVERGREEN/SEMI-EVERGREEN SHRUBS (Screening) (X-15) Botanical Name Common Name rmmum arperor Heght ref Planting m over 10 Years ore t /n 10 Years atroo to Height ore /n f0 Years Ala orCanopy (Min. Cal") (x) (Y) X +Y =T (R) (R) T = D (D)"2. 3.14/4= Abelia grandiflora Glossy Abelia (1''A'-2%) 2 3 5 0.85 4.25 14 Aucuba japonica Japanese Aucuba (1''A'-2%) 2 4 6 0.85 5.1 20 Barbells julianae Wintergreen Barberry (11A'-2%) 2 3 5 0.85 4.25 14 Barbells verruculosa Warty Barberry (134-2%) 2 3 5 0.50 2.5 5 Barbells x gladwynensis'WMlliam Penn" 'Wiliam Penn" Barberry (11A'-2%) 2 2 4 0.50 2 3 Buxus microphylla & cvs. Littleleaf Box (Green Beauty, Wintergreen) (11A'-2%') 21 11 3 0.751 2.25 4 Buxus semper Arens & cvs. American Boxwood (Myer's, Graham Blandy) (11A'-2%') 2 3 5 0.75 3.75 11 Buxus semperArens "Suffruticosa" Dwarf English Boxwood (11A'-2%') 2 2 4 0.90 3.6 10 Buxus & cvs. Boxwood (Green Mountain, Green Velvet) (134-2Yz') 2 2 4 0.90 3.6 10 Cotoneaster dammed & cvs. Bearberry Cotoneaster (Coral Beauty) (134-2%) 1 1 2 0.90 1.8 3 Cotoneaster salic'dollus Willowleaf Cotoneaster (11A'-2%') 2 5 7 0.75 5.25 22 Daphne cneorum Rose Daphne (11A'-2%') 2 4 6 0.90 5.4 23 Daphne odora Fragrant Daphne (11A'-2%') 2 2 4 0.90 3.6 10 Daphne x burkwoodii "Somerset" "Somerset Daphne" (134-2Yz') 2 2 4 0.90 3.6 10 Hypericum caycinum Aaronsbeard St. Johnswort (11A'-2%) 2 2 4 0.90 3.61 10 Ilex cornuta "Burfordii" Burford Holly (11A'-2%') 2 81 101 0.85 8.5 57 Ilex cernuta & cvs. Chinese Holly (Dwarf Burford, Carissa, Rotunda) (11A'-2%') 2 3 5 0.85 4.25 14 Ilex crenata & cvs. Japanese Holly (Compact, Green Luster, Hailed, Hoogendorn, Soft Touch) (11A'-2%') 2 3 5 0.90 4.5 16 Ilex crenata & cvs. Japanese Holly (Bullata 151, Steeds, Nigra) (11A'-2%) 2 2 4 0.90 3.6 10 Ilex glabra & cvs. Inkberry Holly (Compacta, Nigra, Shamrock) (11A'-2%) 2 4 6 0.90 5.4 23 Ilex vomitoria Yaupon (11A'-2%') 2 10 12 0.75 9 64 Ilex x aquipernyi "Dragon Lady" "Dragon Lady" Holly (11A'-2%') 2 10 12 0.65 7.8 48 Ilex x meserveae & cvs. Meserve Holly (Blue Princess/ Prince, Blue Stallion, China Boy/ Girl) (11A'-2%') 3 3 6 0.90 5.4 23 Jasminum nudiflorum Winter Jasmine (11A'-2%) 2 2 4 0.90 3.6 10 Juniperus chinensis & cvs. Chinese Juniper (Kalys Compact, Compact Pfltzer, Blue Pfitzer, Hetz, Sea (11A'-2%') 3 2 5 0.75 3.751 11 Juniperus scepulorum "Wichita Blue" "Wichita Blue" Juniper (1i4'-2'/:') 3 21 51 0.75 3.75 11 Kalmia latifolia Mountain Laurel (Elf, Kaufman's Pink, Olympic Fire) (11A'-2%') 2 2 4 1.50 6 28 Leucothoe axillaris Coast Leucothoe (11A'-2Yz') 2 2 4 1.50 6 28 Leucothoe fontanesiana(catasbaei) Drooping Leucothoe (11A'-2%) 2 3 5 0.75 3.75 11 Ligustrum japonicum Japanese Privet (11A'-2%') 2 4 6 0.80 4.8 18 Mahonia aquifolium Oregon Hollygrape (11A'-2%') 2 2 4 0.40 1.6 2 Mahonia bealei Leatherleaf Mahonia (11A'-2%') 2 4 6 0.50 3 7 Myrica cerifera & cvs. Southern Wax Myrtle (11A'-2Yz') 3 7 10 0.75 7.5 44 Myrica penslyvanica Northern Bayberry (11A'-2%) 3 3 6 0.80 4.8 18 Nandina domestics Nandina or Heavenly Bamboo (11A'-2%') 2 5 7 0.66 4.621 17 Osmanthus heterophyllus & cvs. Holly Osmanthus (11A'-2%') 2 81 101 0.85 8.5 57 Osmanthus x fortunei Fortune's Osmanthus (11A'-2%') 5 10 15 0.75 11.25 99 Photinia x frazeri Red Pholinia (11A'-2%) 2 8 10 0.50 5 20 Picea abies'Little Gem' Dwarf Norway Spruce (11A'-2%) 2 1 3 0.65 1.95 3 Picea abies'Nidiformis' Birds Nest Spruce (11A'-2%') 2 3 5 0.66 3.3 9 Pieris floribunda Mountain Pieris (11A'-2%') 2 3 5 0.85 4.25 14 Pieris japonica & cvs. Japanese Pieris (Dorothy Wycoff, Mountain Fire, Snowdrift, Valentine) (11A'-2%') 3 6 9 0.75 6.75 36 Pinus mugo Mugo Dwarf Mountain Pine (11A'-2%) 3 9 12 0.90 10.8 92 Prunus laurocerasus & cvs. Cherry Laurel (Otto Luyken, Schipkaensis) (11A'-2%') 2 2 4 0.90 3.6 10 Pyracantha'Lowboy' Lowboy Firethom (11A'-2%') 2 1 3 0.90 2.71 6 Pyracantha x cvs. Firethom (Fiery Cascade, Mohave, Navaho, Rutgers) (11A'-2%') 21 7 91 0.90 8.1 52 Pyracantha coccinea'Lalandei' Orange Laland Firethom (11A'-2Yz') 2 6 8 0.75 6 28 Rhododendron spp. Azalea (Glenn Dale, Gable, Girard, Kurume, Satauki) (11A'-2%) 2 2 4 0.90 3.6 10 Rhododendron spp. Rhododendron (Catawba, Fortune's, PJM, Rosebay, Scintillation) (11A'-2%') 3 5 8 0.50 4 13 Sarrwcocca Hookerana var. humilis Dwarf Himalayan Sweet Box (11A'-2%') 2 2 4 0.90 3.6 10 Sarcococca ruscifolia Sweet Box (11A'-2%') 2 1 3 0.90 2.7 6 SWmmia japonica Japanese Skimmia (11A'-2Yz') 2 1 3 0.90 2.7 6 Taxus baccata "Repandens" English Spreading Yew (1i4'-2%) 2 2 4 1.50 6 28 Taxus cuspidata &cvs. Japanese Yew (Hunneywelliana, Intermedia, Sieboldii (1i4'-2%') 2 4 6 1.60 72 0 reoruwy 200 v Vr t 1 > "-v Botanical Name Common Name rmmum arper,r Height Heightat Planting GmwMmr 10 Years lotatHeight In 10 Years HaWo to Height almikIth In f0 Years Ala orCanopy (Min. CeL/Ht.) (xf (Y) X+Y=T (R) (R)T=D (D)"2'3.14/4= Taxus x media & cvs. Anglojap Yew (Brown's, Cedar Hill, Densiformis, Hatfield, Hick's, Kelsey, (1'A'-2%') 2 1 3 0.65 1.95 3 Vibumum x burkwoodii Burkwood Vibumum (1'A'-2%') 4 4 8 0.66 5.28 22 Vibumum x pragense Prague Viburnum (1'A'-2%') 5 5 10 0.75 7.5 44 Vibumam rhytidophyllum"Alleghany" "Alleghany"Yburnam (1i4-2%) 5 5 10 0.90 9 64 Vibumum utile "Conoy" "Conoy" Vibumum (1'A'-2%) 2 2 4 1.20 4.8 18 05 February 2003 7 of 11 LD-6 DECIDUOUS SHRUBS (3=30) Botanical Name Common Name rmi� Height tat Planting m over 10 Years ote t In 10 Yees atroo to Height ote In f0 Years Ala orCenopy (Min. CeL") (x) (Y) X +Y =T (M (M T = D (D)"2.3.1414= Aesculus parviflora Bottlebrush Buckeye (1'-1'/=') 1 7 8 0.85 6.8 36 Aronia arbutifolia "Brilliantissima" Brilliant Red Chokeberry, (1--IY.) 1 5 6 0.50 3 7 Buddlela davidii Butterfly Bush (1--IY.) 1 6 7 0.65 4.55 16 Callicarpa dichotoma Purple Beautyberry (1'-I Y.-) 1 3 4 1.20 4.8 18 Callicarpa japonica Japanese Beautyberry, (1'-1'/=') 1 3 4 0.90 3.6 10 Calycanthus floridus Common Sweetshrub or Carolina Allspice (1--1 %') 1 51 61 0.95 5.71 26 Caryopteris "Longwood Blue" Blue Mist Shrub (1--IY.) 1 3 4 0.90 3.6 10 Cephalanthus occidentalis Buttonbush (1--IY.) 1 3 4 0.85 3.4 9 Clethra alnifolia & cvs. Summersweet Clethra (Hummingbird, Roses, Ruby Spice, September Beauty) (1'-I Y2) 1 5 6 0.75 4.5 16 Comus alba "Argenteo-marginata" European Variegated Dogwood (1'-1'/=') 1 7 8 0.75 6 28 Comus racemosa Gray Dogwood (1'-1 %') 1 9 10 0.90 9 64 Comus sericea & cvs. Red -twig Dogwood (Bailey's, Cardinal) (1'-I Y2.) 1 7 8 1.20 9.6 72 Comus sericea "Flaviramea" Yellowtwig Dogwood (1'-I Y2.) 1 7 8 1.20 9.6 72 Cotoneaster apiculatus Cranberry Cotoneaster (1'-1 %) 1 2 3 1.00 3 7 Cotoneaster horizontalis Rockspray Cotoneaster (1'-I Y2) 1 2 3 1.20 3.6 10 Deutzia gracillis & cvs. Slender Deutzia (Nikko) (1'-I Y2.) 1 2 3 1.20 3.6 10 Forsythia x intemtedia & cvs. Forsythia (Lynwood, Spectabills, Spring Glory) (1'-1'/=') 3 21 51 0.90 4.51 16 Fothergilla garden!! Dwarf Fothergilla (1'-IY2.) 1 1 2 0.90 1.8 3 Fothergilla major Large Fothergilla (1'-I Y2) 1 5 6 0.85 5.1 20 Hamamelis x intermedia & cvs. Witchhazel (Arnold Promise, Diana, Winter Beauty) (1'-I Y2) 1 10 11 0.90 9.9 77 Hamamelis mollis Chinese Witchhazel (1'-I Y2.) 1 9 10 0.90 9 64 Hamamelis vernalls Vernal Wtchhazel (1'-IY2.) 1 5 6 0.90 5.4 23 Hydrangea quercifolia & cvs. Oakleaf Hydrangea (Alice, Snowqueen, Ellen Huff) (1'-I Y2') 1 4 5 0.90 4.5 16 Hypericum x "Hidcote" "Hidcote" St. Johnswort (1'-I Y2) 1 2 3 0.90 2.7 6 Ilex decidua Possumhaw (1'-IY2) 1 8 9 0.80 7.2 41 Ilex verticillata & cvs. Winterberry Holly (Harvest Red, Late Male, Red Sprite, Winter Red, (1'-I Y2.) 1 7 8 0.90 7.2 41 Itea virginica "Henry's Garnet" "Henry's Garnet" Sweetspire (1'-1'/=') 1 51 61 1.50 91 64 Kerrie japonica Japanese Kerrie (1'-I Y2.) 1 7 8 1.20 9.6 72 Ligustrum amurence "North River" "North River" Privet (1'-I Y2) 1 11 12 0.66 7.92 49 Lindera benzoin Spicebush (1'-IY2.) 1 5 6 0.90 5.4 23 Physocarpus opulifolius Darfs Golden "Dart's Golden" Ninebark (1'-I Y2.) 1 4 5 1.00 5 20 Potentilla fruticosa & cvs. Cinquefoil (Abbotswood, Gold Drop, Goldfinger, McKay's White) (1'-1'/=') 1 2 3 1.00 3 7 Prunus cistena Purpleleaf Sand Cherry (1'-1 %) 1 6 7 0.85 5.95 28 Rhus aromatics Fragrant Sumac (1'-1 %) 1 4 5 1.30 6.5 33 Rhus copallina Flameleaf Sumac (1'-I Y2.) 1 15 16 1.20 19.2 289 Rhus glabra Smooth Sumac (1'-1 %') 1 8 9 1.00 9 64 Rhus typhina Staghom Sumac (1'-I Y2.) 1 14 151 1.20 181 254 Spiraea x bumalda & cvs. Spires (Neon Flash) (1'-I Y2) 1 2 3 1.00 3 7 Spiraea nipponica & cvs. Spires (Snowmound) (1'-I Y2) 1 2 3 1.00 3 7 Spiraea x vanhouttei Vanhoutte Spires (1'-1'/=') 1 5 6 1.20 7.2 41 Syringe meyeri "Palibin" Compact Meyer Lilac (1'-1'/=') 1 4 5 1.50 7.5 44 Syringe patula "Miss Kim" "Miss Kim" Manchurian Lilac (1'-I Y2.) 1 4 5 1.00 5 20 Syringe x chinensis Chinese Lilac (1'-I Y2) 1 7 8 1.00 8 50 Viburnum dentatum Arrowwood Viburnum (Chicago Lustre) (1'-I Y2) 1 6 7 0.90 6.3 31 Viburnum lantana & cvs. Wayfaringtree Viburnum (Mohican) (1'-I Y2.) 1 11 12 1.00 12 113 Viburnum lentago Nannyberry Viburnum (1'-IY2.) 1 14 15 0.60 9 64 Viburnum nudum "Winterthur" "Winterthur" Viburnum (1'-IY2) 1 51 61 1.00 6 28 Viburnum opulus "Sterile" Old Fashioned Viburnum (1'-IY2.) 1 7 8 1.20 9.6 72 Viburnum plicatum & cvs. Snowball Viburnum (Popcorn, Triumph) (1'-I Y2.) 1 7 8 1.00 8 50 Viburnum plicatum tomentosum & cvs. Doublefile Viburnum (Igloo, Mariesil, Shasta, White Delight) (1'-I Y2.) 1 7 8 1.00 8 50 Viburnum prunifollum Blackhaw Viburnum (1'-IY2.) 1 11 12 0.75 9 64 Viburnum trilobum American Cranberrybush Viburnum (1'-I Y2.) 1 7 8 1.00 8 50 Viburnum x carlcephalum & cvs. Fragrant Viburnum (Cayuga) (1'-I Y2) 1 5 6 1.00 6 28 I-Vibumurn x u u' I Judd Viburnum - ENTRANCE CORRIDOR PLANT CALCULATIONS LARGE DECIDUOUS TREES (50.70) 3W Caliper (Shade and/or Street) Botanioel Name Common Name rmmum a�peror Height tat Planting m over7WHeight 10 Years /n 10 Years atroo to Height ote /n f0 Yeers Area of Cenopy (Min. Call") (x) (Y) X+Y=T (R) (R) T=D (D)"2.3.1414= Acer nigrum & cvs. Black Maple (31A" Cal.) 14 12 26 0.66 17.16 231 Acer rubrum & cvs. Red (Swamp) Maple (Oct. Glory, Red Sunset) (31/4" Cal.) 14 20 34 0.75 25.5 510 Acer rubrum "Armstrong" "Armstrong" Red Maple (31/4" Cal.) 14 20 34 0.25 8.5 57 Acer saccharum & cvs. Sugar Maple (Bonfire, Commemoration, Green Mountain, Legacy) (31/2" Cal.) 14 10 24 0.75 18 254 Acer x freemanii "Jeffersred" Autumn Blaze Maple (31/2" Cal.) 14 20 34 0.75 25.5 510 Aesculus hippocastanum Common Horsechestnut (31/4" Cal.) 16 16 32 0.90 28.8 651 Betula nigra "Heritage" "Heritage" River Birch (31/2" Cal.) 14 15 29 0.90 26.1 535 Carya glabra Pignut Hickory (31/4" Cal.) 15 5 20 0.55 11 95 Carya ovate Shagbark Hickory (31/4" Cal.) 15 5 20 0.60 12 113 Celtis x occidentalis "Magnifca" "Magnifca" Hackberry (31/4" Cal.) 14 20 34 0.90 30.6 735 Diospyros virginiana Persimmon (31/4" Cal.) 15 8 22.5 0.75 16.875 224 Fagus grandifolia American Beech (31/2" Cal.) 14 10 24 0.85 20.4 327 Fagus sylvatica & cvs. European Beech (31/2" Cal.) 14 10 24 0.75 18 254 Fraxinus americans & cvs. White Ash (Autumn Purple) (31/2" Cal.) 16 151 31 0.75 23.251 424 Fraxinus americana "Rosehill" "Rosehill" White Ash (31/2" Cal.) 16 15 31 0.50 15.5 189 Fraxinus americans "Greenspire" "Greenspire" White Ash (31/2" Cal.) 16 15 31 0.25 7.75 47 Fraxinus pennsylvanica & cvs. Green Ash (Newport, Patmore, Summit, Urbanite) (31/2" Cal.) 16 25 41 0.75 30.75 742 Ginkgo biloba "Magyar" "Magyar" Ginkgo (31/4" Cal.) 15 10 251 0.50 12.5 123 Ginkgo biloba "Princeton Sentry" "Princeton Sentry" Ginkgo (31/4" Cal.) 15 10 25 0.20 5 20 Gleditsia triacanthos inermis & cvs. Thornless Honeylocust (31/2" Cal.) 15 20 35 0.75 26.25 541 Gymnocladus dioicus & cvs. Kentucky Coffeetree (31/4" Cal.) 14 25 39 0.77 30.03 708 Halesia monticola Mountain Silverbell (31/2" Cal.) 14 15 29 0.66 19.14 288 Liquidambar styraciflua Sweetgum (31/4" Cal.) 16 15 31 0.66 20.46 329 Liquidambar styraciflua "Rotundiloba" "Rotundiloba" Sweetgum (31/4" Cal.) 16 15 31 0.601 18.6 272 Liriodendron tulipifera Tuliptree or Tulip Poplar (31/2" Cal.) 16 25 41 0.60 24.6 475 Magnolia acuminata Cucumbertree Magnolia (31/2" Cal.) 14 20 34 0.60 20.4 327 Metasequoia glyptostroboides Dawn Redwood (31/4" Cal.) 14 251 39 0.25 9.75 75 Nyasa sylvatica Blackgum Tree (31/4" Cal.) 15 8 23 0.66 15.18 181 Platanus x acerifolia & cvs. London Planetree (Bloodgood) (31/2" Cal.) 15 18 32.5 0.76 24.7 479 Platanus occidentalis American Planetree (Sycamore) (31/4" Cal.) 16 35 51 0.85 43.35 1475 Quercus alba White Oak (31/2" Cal.) 14 12 26 0.80 20.8 340 Quercus bicolor Swamp White Oak (31/4" Cal.) 15 20 35 0.63 22.05 382 Quercus coccinea Scarlet Oak (31/2" Cal.) 15 20 351 0.70 24.51 471 Quercus falcate Southern Red Oak (31/2" Cal.) 14 23 37 0.75 27.75 604 Quercus imbriraria Shingle Oak (31/2" Cal.) 14 10 24 0.66 15.84 197 Quercus palustris Pin Oak (31/2" Cal.) 151 20 35 0.70 24.5 471 Quercus palustris "Green Pillar Pin Oak (31/4" Cal.) 151 20 35 0.20 7 38 Quercus phellos Willow Oak (31/2" Cal.) 15 20 35 0.70 24.5 471 Quercus prinus Chesnut Oak (31/2" Cal.) 14 12 26 0.70 18.2 260 Quercus robur English Oak (31/4" Cal.) 15 20 35 0.66 23.1 419 Quercus robur & cvs. "Fastigate" English Oak (31/4" Cal.) 15 10 25 0.20 5 20 Quercus rubra Northern Red Oak (31/4" Cal.) 15 20 35 0.75 26.25 541 Quercus shumardii Shumard Oak (31/4" Cal.) 15 20 351 0.66 23.11 419 Salix alba & cvs. Golden Weeping Willow (31/4" Cal.) 14 30 44 0.85 37.4 1098 Taxodium distichum & cvs. Bald Cypress (31/4" Cal.) 14 15 29 0.40 11.6 106 Tilia americans "Redmond" "Redmond" Linden (31/4" Cal.) 15 15 30 0.60 18 254 Tilia cordata "Greenspire" "Greenspire" Littleleaf Linden (31/4" Cal.) 16 15 31 0.66 20.46 329 Tilia tomentosa "Green Mountain" "Green Mountain" Silver Linden (31/2" Cal.) 14 15 29 0.75 21.75 371 Ulmus americana & cvs. American Elm (Princeton, Washington) (31/2" Cal.) 14 15 29 0.90 26.1 535 Ulmus pawifolia "Allee" "Allee" Elm (31/2" Cal.) 16 15 31 0.80 24.8 483 Zelkova serrate "Green Vase" "Green Vase" Zelkova (31/4" Cal.) 16 20 36 0.66 23.76 443 Zelkova serrate "Village Green" "Village Green" Zelkova (31/2" Cal.) 1 16 20 36 0.75 27 572 05 February 2003 9 of 11 LL-6 LARGE DECIDUOUS TREES (50 -70) 216" Caliper (Shade and/or Street) Botanical Name Common Name rmmum a�peror Height tat Planting m over 10 Years ote t /n 10 Years atroo to Heght ote /n f0 Years Ala orCenopy (Min. Cal-") (x) (Y) X+Y=T (R) (R) T=D (D)"2.3.1414= Acer nigrum & cvs. Black Maple (21/." Cal.) 12 12 24 0.66 15.84 197 Acer rubrum & cvs. Red (Swamp) Maple (Oct. Glory, Red Sunset) (21/2" Cal.) 12 20 32 0.75 24 452 Acer rubrum "Armstrong" "Armstrong" Red Maple (21/2" Cal.) 13 20 33 0.25 8.25 53 Acer saccharum & cvs. Sugar Maple (Bonfire, Commemoration, Green Mountain, Legacy) (21/2" Cal.) 12 10 22 0.75 16.5 214 Acer x freemanii "Jeffersred" Autumn Blaze Maple (21/2" Cal.) 12 20 32 0.75 24 452 Aesculus hippocastanum Common Horsechestnut (21/2" Cal.) 14 16 30 0.901 271 572 Betula nigra "Heritage" "Heritage" River Birch (21W Cal.) 12 15 27 0.90 24.3 464 Carya glabra Pignut Hickory (21W Cal.) 13 5 18 0.55 9.9 77 Carya ovate & cvs. Shagbark Hickory (21W Cal.) 13 5 18 0.60 10.8 92 Celtis x occidentalis "Magnifca" "Magnifca" Hackberry (21W Cal.) 12 20 32 0.90 28.8 651 Diospyros virginiana Persimmon (21W Cal.) 13 8 20.5 0.75 15.375 186 Fagus grandifolia American Beech (21W Cal.) 12 10 22 0.85 18.7 275 Fagus sylvatica & cvs. European Beech (21W Cal.) 12 10 22 0.75 16.5 214 Fraxinus americans & cvs. White Ash (Autumn Purple) (21W Cal.) 14 15 29 0.75 21.75 371 Fraxinus americans "Rosehill" "Rosehill" White Ash (21W Cal.) 14 15 29 0.50 14.5 165 Fraxinus americans "Greenspire" "Greenspire" White Ash (21W Cal.) 141 151 29 0.251 7.25 41 Fraxinus pennsylvanica & cvs. Green Ash (Newport, Patmore, Summit, Urbanite) (21W Cal.) 14 25 39 0.75 29.25 672 Ginkgo biloba "Magyar" "Magyar" Ginkgo (21W Cal.) 13 10 23 0.50 11.5 104 Ginkgo biloba "Princeton Sentry' "Princeton Sentry" Ginkgo (21W Cal.) 13 10 23 0.20 4.6 17 Gleditsia triacanthos inermis & cvs. Thornless Honeylocust (21W Cal.) 13 20 33 0.75 24.75 481 Gymnocladus dioicus & cvs. Kentucky Coffeetree (21W Cal.) 12 25 37 0.77 28.49 637 Halesia monticola Mountain Silverbell (21/2" Cal.) 12 15 27 0.66 17.82 249 Liquidambar styraciflua Sweetgum (21/2" Cal.) 14 15 29 0.66 19.14 288 Liquidambar styraciflua "Rotundiloba" "Rotundiloba" Sweetgum (21/2" Cal.) 14 15 29 0.60 17.4 238 Liriodendron tulipifera Tuliptree or Tulip Poplar (21/2" Cal.) 14 25 39 0.60 23.41 430 Magnolia acuminata Cucumbertree Magnolia (21W Cal.) 121 201 32 0.60 19.2 289 Metasequoia glyptostroboides Dawn Redwood (21W Cal.) 12 25 37 0.25 9.25 67 Nyasa sylvatica Blackgum Tree (21W Cal.) 13 8 21 0.66 13.86 151 Platanus x acerifolia & cvs. London Planetree (Bloodgood) (21W Cal.) 13 18 30.5 0.76 23.18 422 Platanus occidentalis American Planetree (Sycamore) (21W Cal.) 14 35 49 0.85 41.65 1362 Quercus alba White Oak (21W Cal.) 12 12 24 0.80 19.2 289 Quercus bicolor Swamp White Oak (21W Cal.) 13 20 33 0.63 20.79 339 Quercus coccinea Scarlet Oak (21W Cal.) 13 20 33 0.70 23.1 419 Quercus falcate Southern Red Oak (21W Cal.) 12 21 33 0.75 24.75 481 Quercus imbricaria Shingle Oak (21W Cal.) 12 10 221 0.66 14.521 166 Quercus palustris Pin Oak (21W Cal.) 131 20 33 0.70 23.1 419 Quercus palustris "Green Pillar Pin Oak (21W Cal.) 131 20 33 0.20 6.6 34 Quercus phellos Willow Oak (21W Cal.) 13 20 33 0.70 23.1 419 Quercus prinus Chesnut Oak (21W Cal.) 12 12 24 0.70 24 452 Quercus robur English Oak (21W Cal.) 13 20 33 0.66 21.78 372 Quercus robur & cvs. "Fastigate" English Oak (21W Cal.) 13 10 23 0.20 4.6 17 Quercus rubra Northern Red Oak (21W Cal.) 13 20 33 0.75 24.75 481 Quercus shumardii Shumard Oak (21W Cal.) 13 20 33 0.66 21.78 372 Salix alba & cvs. Golden Weeping Willow (21W Cal.) 12 30 42 0.85 35.7 1000 Taxodium distichum & cvs. Bald Cypress (21/2" Cal.) 12 15 27 0.401 10.81 92 Tilia americans "Redmond" "Redmond" Linden (21W Cal.) 13 15 28 0.60 16.8 222 Tilia cordata "Greenspire" "Greenspire" Littleleaf Linden (21/2" Cal.) 14 15 29 0.66 19.14 288 Tilia tomentosa "Green Mountain" "Green Mountain" Silver Linden (21W Cal.) 12 15 27 0.75 20.25 322 Ulmus americana & cvs. American Elm (Princeton, Washington) (21W Cal.) 12 15 27 0.90 24.3 464 Ulmus pawifolia "Allee" "Allee" Elm (21W Cal.) 14 15 29 0.80 23.2 423 Zelkova serrate "Green Vase" "Green Vase" Zelkova (21W Cal.) 14 20 34 0.66 22.44 395 Zelkova serrate "Village Green" "Village Green" Zelkova (21W Cal.) 14 20 34 0.75 25.5 510 LL MEDIUM DECIDUOUS TREES (40 -50) 2W Caliper Botanical Name Common Name rmr� Height tef Planting m over 10 Years ote t /n 10 Years atroo to Height ote /n f0 Years Ala ofCanopy (Min. Cal") W (Y) X+Y=T (R) (R) T=D (D)-2. 3.14/4= Acer rubrum & cvs. Red Maple (Autumn Flame, Bowhall) (21A" Cal.) 13 10 23 0.75 17.25 234 Acer saccharum "Goldspire" "Goldspire" Sugar Maple (21/2" Cal.) 14 10 24 0.50 12 113 Acer truncatum x platanoides "Keithsform" Norwegian Sunset Maple (21/2" Cal.) 12 10 22 0.66 14.52 166 Carpinus betulus European Hombeam (21/2" Cal.) 13 10 23 0.75 17.25 234 Celtis laevigata 'Al Seasons" "Al Seasons" Sugar Hackberry (21/2" Cal.) 12 20 32 0.75 24 452 Cercidiphyllum japonicum Katsuratree (21/2" Cal.) 12 20 32 0.60 19.2 289 Corylus celurna Turkish Filbert (21/2" Cal.) 12 18 29.5 0.50 14.75 171 Salix nigra Black Willow (21/2" Cal.) 0 0 0 Sassafras albidum Common Sassafras (21/2" Cal.) 12 15 27 0.66 17.82 249 Sophora japonica "Princeton Upright" "Princeton Upright" Scholartree (21/2" Cal.) 12 20 32 0.70 22.4 394 Sophora japonica "Regent" "Regent" Scholartree (21/2" Cal.) 12 20 32 0.80 25.6 514 05 February 2003 11 of 11 LD-6