Loading...
HomeMy WebLinkAboutSDP201800003 Plan - Approved Letter of Revision 2 2020-08-21LETTER OF REVISION #2 FOR LEGEND EXIST NEW DESCRIPTION 16, -rC x 125 TC TOP OF CURB ELEVATION W X 125 SPOT ELEVATION 16, TW x 125 TW TOP OF WALL ELEVATION 161BW x 125BW BOTTOM OF WALL ELEVATION BENCHMARK — STORM SEWER ---- RQ ROOF DRAIN —� — SEWER LINE WATER LINE ---- GAS GAS LINE c CHE OVERHEAD ELECTRIC WIRE UGE UNDERGROUND ELECTRIC . - GHT OVERHEAD TELEPHONE LINE ---�--ae UGT UNDERGROUND TELEPHONE LINE — — — — GAS CONDUIT DRAIN INLET (DI) O STORM/SANITARY MANHOLE E C PLUG OW ®N WATER VALVE & BOX . FIRE HYDRANT WATER METER LIGHT POI F M� UTILITY POLE PROPERTY LINE ADJACENT PROPERTY LINE ------- VACATED PROPERTY LINE -c — BUILDING SETBACK — PARKING SETBACK SANITARY EASEMENT CONSTRUCTION EASEMENT DRAINAGE EASEMENT �--®- ----- - �-- UTILITY EASEMENT ----•----- - WATER EASEMENT - -- - - - - - ACCESS EASEMENT -�- - ----- STORM DRAINAGE EASEMENT ---- GAS LINE EASEMENT LANDSCAPING EASEMENT TREE LINE - ---- ---� FENCE STREAM 312 12 INTERVAL CONTOUR 300— oo INDEX CONTOUR CG-2 Cc-2 STANDARD 6" CURB CG--6 CG-6 COMBINATION 6" CURB & GUTTER CONCRETE PAVEMENT / SIDEWALK RIPRAP ASPHALT GRASS EC-2 MATTING EC-3 MATTING •,•°°a°,•°•° WETLAND to 10 PARKING COUNT CROSSWALK HANDICAP ACCESSIBLE AISLE ZFN CG-12 6% clv HANDICAP PARKING HAN5EN ROAD CHURCH TMP 07800-00-00-O73AB, SDP 201600003 RIVANNA DISTRICT, ALBEMARLE COUNTY, VIRGINIA SHEET C2 IMAGE PROVIDED BY GOOGLE MAPS -T X Z-SHZTC I -COVER 5f1EE 5h1EET C3 -EXISTING CONDITIONS * DEMO SHEET C4 - EXISTING EASEMENTS CIEC - VIEW / 51GFiT DISTANCE LINES - SITE PLAN SHEETS C3 * C4rSNFF=T - GPADING PLAN SHEETS C5 � CG - AN S-CAPINC2 PL N H T S SHEET C7 I - LIGHTING PLAN SHEETS C8 * C9 SNFFT ' `' - DRAINAGE MAP - EI LES AND DETAILS SHEET C 14 - WATEP. � SEWEK PKOEI LES AND DETAILS SHEET C 15 - SITE DETAILS SHEET C I C- 19 - RETAINING WALL DETAILS SIGNATURE BLOCK CURRENT DEVELOPMENT PLANNER CURRENT DEVELOPMENT ENGINEER ALBEMARLE COUNTY SERVICE AUTHORITY FIRE OFFICIAL ARCHITECTURAL REVIEW BOARD BUILDING OFFICIAL OWNER / DEVELOPER Owner: Point Church 1428 Greenbrier Place Charlottesville VA, 22901 Developer: Core Real Estate and Development 195 Riverbend Drive Charlottesville VA, 22911 ZONING Planned Development Mixed Commercial Entrance Corridor (EC) Steep Slopes - Managed Parcel, Owner Impacted by Site Plan: 78-73AA, Albemarle Land LLC 78-7381+, Hansen Road Professional Center LLC et al. 78-3A6+, Virginia School Boards Association et al. Original Approved ZMA 1998-20 Amended ZMA 2002-08 ZMA 2018-2 Owner Subject to Four Party Road Improvement Agreement dated 09/21/1998, Deed Book 1899 Pg. 402 LEGAL REFERENCE TMP 07800-00-00-073AB - DB 4416 PG 460 DB 4786/17 PLAT BENCHMARK Benchmark for topographic survey is the top of a sewer manhole located northeast of the site. Elev. = 536.95' Datum: NAVD88 SOURCE OF BOUNDARY & TOPO Boundary & topographic survey information provided by. Commonwealth Land Surveying 319 Rio Road W Charlottesville, VA 22901 2/6/17 Additional topography provided by Albemarle County GIS BUILDING HEIGHT Maximum: 65' Floors above 40' or the third story shall be stepped back a minimum of 15' from the front of the building. Proposed Height: (Church) 34' SETBACKS Front Max: 30' from right of way or exterior edge of sidewalk if outside right of way Front Min: 10' from right of way or exterior edge of sidewalk if outside right of way *Note: Setbacks shown on the plans are measured from the private street easement from both Rolkin Road and Hansen Road Side & Rear: Adjacent to RA district boundary, residential, or Monticello Historic District Building Min. 50', Max. None Parking Min. 20', Max. None Adjacent to commercial or industrial Structure shall be constructed and separated in accordance with current edition of Building Code. EXISTING USE Vacant Land PROPOSED USE 28,246 SF Church with Associated Parking FLOOD ZONE According to the FEMA Flood Insurance Rate Map, effective date February 4, 2005 (Community Panel 51003CO289D), this property does not lie within the Zone AE 100-year flood plain. WATER & SANITARY SERVICES All water and sanitary sewer services are to be provided by Albemarle County Service Authority. Backflow prevention measures shall be installed in accordance with ACSA Standards. WATERSHED This site is not located within a water supply protection area. LIGHTING Proposed lighting and photometrics are included on Sheet C10. LAND USE SCHEDULE EXISTING Road Sidewalk Open space Area 29,833 SF 10,839 SF 226,863 SF % 11.15% 4.05% 84.80% Total= 267,535 SF (6.14 ac.) PROPOSED Area % Building 11,402 SF 8.19% Pavement 109,816 SF 78.91 % Walkways 17,948 SF 12.90% Impervious area 139,166 SF 52.02% Open space 128,369 SF 47.98.% Total= 267,535 SF (6.14 ac.) SIGNS All signs shall conform with the MUTCD Guidelines. ITE TRIP COUNT Trip Generation Manual, loth Edition AM PM Use Description ITE Qty in out Total in out Total Church Sunday Peak Hour 560 28246 sf 142 153 295 Church Weekday 560 128246sf 10 8 18 16 10 25 REOU I RED IMPROVEMENTS 1. In the event that the owner of the adjacent property TMP 78-73A1, which holds a stormwater easement across TMP 78-73AB as shown on this site plan, were to damage or destroy any of the required improvements shown on this site plan (including but not limited to parking areas, access aisles, curb and gutter, retaining walls, landscaping, as well as storm drain pipes and structures) the owner of TMP 78-73AB would be fully responsible for the �se n o e im eme or i olation of plan..poncompletion of path, its location must be surveyed and a 6 ft access easement must be recorded around its exact location, along with a maintenance agreement, prior to obtaining the certificate of occupancy. Lo4f 4-,-7 Submittal Type Reviewed and Approved by the Commur ty evelop ent Department Date �� File# � 20 bc�b �_ L D ✓: NOTE: 1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOWN. VIRGINIA DEPARTMENT OF TRANSPORATION atureAz, � �{ (4 S} / 1 J � i r� / / / e / EX ND III*, ST / ELO �,E WWA� j TREE PROTECTION FENCING / TREE PROTECTION FENCIN ttNtNG WA- -C` " AX�IEIG XMIX r � � r � r r ! r 30 SCALE: 1 " _ 0 30 BO 90 PROPOSED LANDSCAPE SCHEDULE Plant Symbol Planting Type Botanical Name Common Name Min Cal./Height Quantity Total Height(ft) CaSFpy Total Canopy Plan Reference in 10 Yrs SF Large Deciduous Tree Quercus alba White Oak 2.5" 25 22 243 6075 Large Deciduous Tree Quercus bicolor Swamp White Oak 2.5" 25 20 299 7475 Large Deciduous Tree Fagus grandifolia American Beech 2.5" 4 20 227 908 Large Deciduous Tree Acer x freemanii Autumn Blaze Maple 2.5" 8 20 397 3176 0 Large Deciduous Tree Ulmus americans cvs. American Elm Valley Forge' 2.5' 9 15 397 3573 Large Deciduous Tree Liquidambar styraciflua Sweetgum 2.5" 8 15 249 1992 Broadleof Evergreen Magnolia grandiflora Southern Magnolia 3-4' Ht. 12 14 54 648 .j Broadleaf Evergreen Juniperus virginiana Eastern Redcedar 3-4' Ht. 12 14 16 192 { Broadleaf Evergreen Pinus strobus White Pine 2.5" 26 24 118 3068 Evergreen Tree Tsuga canadensis Eastern Hemlock 2.5" 5 10 16 80 S?i�s Small Flowering Tree Magnolia virginiana Sweet Ba y Magnolia 6' 26 10 113 2938 Small Flowering Tree Cersis canadensis Eastern Redbud 6' 15 10 124 1860 Broadleaf Evergreen Shrub Magnolia grandiflora 'Little Little Gem Magnolia 6' 60 22 82 4920 Gem' Broadleaf Evergreen Shrub Myrica penslyvanica Northern Bayberry 24" Ht. 60 3 18 1080 Broadleaf Evergreen Shrub Ilex vomitoria Youpon Holly 24" Ht. 60 3 16 960 Deciduous Shrub Fathergilla gardenii Dwarf Fathergilla 24" Ht. 60 0 Low Maintenance Ground Cover 1 Southeast Native Grass Seed Mix .866ac Low Maintenance Ground Cover 2 Southeast Wildflower Seed Mix 101b TOTAL SF: 38945 LANDSCAPING REQUIRED: SITE REQUIREMENT (32.7.9.8): 10% CANOPY REQUIRED. SITE AREA 267,535 SF x 10% = 26,754 SF CANOPY REQUIRED: 26,754 SF CANOPY PROVIDED: 38,945 SF CANOPY PROVIDED STREET TREES (32.7.9.5): LARGE SHADE TREES (2.5" CAL.) — 40' O.C. PARALLEL TO ROAD HANSEN RD — 396 LF/40 = 10 ROLKIN RD — 1,320 LF/40 = 33 ROLKIN RD (OFF PROPERTY) — 428 LF/40 = 11 REQUIRED 54 LARGE SHADE TREES PROVIDED 54 LARGE SHADE TREES 11 ALONG HANSEN RD & 45 ALONG ROLKIN RD. NOTE: TREES OCCASIONALLY NOT 40' O.C. DUE TO SITE RESTRAINTS SUCH AS 'SIGHT DISTANCE TRIANGLE' AND EASEMENTS. THREE PRESERVED TREES ALONG ROLKIN COUNTED TOWARD STREET TREE CALCULATION. INTERIOR/PARKING LANDSCAPE (32.7.9.6): 5% OF PARKING PAVED AREA, 46,281 SF X .05 = 2,314.05 SF REQUIRED 2,314.05 SF OF LANDSCAPED AREA PROVIDED: 9,106 SF OF LANDSCAPED AREA LARGE SHADE TREES (2.5" CAL.) 160 PARKING SPACES (16 / 10 = 16) REQUIRED 16 LARGE SHADE TREES PRQVIDED:16 LARGE SHADE TREES SCREENING SHRUBS — AS NECESSARY TO MINIMIZE APPEARANCE OF PARKING & AND RETAINING WALLS NOTES: 1. Contractor to apply 4' diameter by 2-5" mulch bedding around all proposed trees, and mulch bedding around shrubs. 2. All other landscaped areas shall be sodded. 3. All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant. 4. All landscaping and screening shall be maintained in a healthy condition by the current owner or property 1� owners' association and replaced when necessary. Replacement material shall comply with the approved w landscape plan. 5. All new planting shown on the plan will be completed after building and road construction to avoid tree planting damage. 6. All disturbed slopes 3:1 or steeper to have low maintenance ground cover. f 7. Any existing tree proposed to remain shall be replaced in kind if negatively impacted by improvements / associated with this project. MAINTENANCE: * LOW MAINTENANCE GROUND COVER —The best time of year to mow is during the fall through late winter. Mow , on a three—year cycle where 1/3 of the area is mowed each year. Do not mow during the spring or summer months because of the nesting season. When mowing, cut grass no lower than 6 inches and allow stubble to remain until spring to help insulate plant roots and provide cover for wildlife. If native warm —season grasses are / cut lower than 6 inches during the active growing season, the stand will be reduced significantly. / — PLANTING GUIDE 'AMERICUS'INDIANGRASS Sorghastrum nutans USDA—NRCS Jimmy Carter PMC Americus, Georgia SEED MIXES:} SOUTHEAST NATIVE GRASS SEED MIX (AMERICAN MEADOWS INC.) — Mix the following seeds:- • Kentucky 31 Fescue (Festuca arundinacea) — 100 lb/acre, Red Top Grass (Agrostis gigantea) — 20 Ib/acre, Virginia Wildrye (Elymus virginicus) — 20 lb/acre, Little Bluestein Grass (Schizachyrium scoporium) — 20 lb/acre, Purpletop (Tridens flavus) — 20 lb/acre, and Broomsedge (Andropogon virginicus) — 20 lb/acre, Indian Grass (Sorghastrum nutans) — 20 lb/acre. SOUTHEAST WILDFLOWER SEED MIX (AMERICAN MEADOWS INC.) — The mixture includes: 30 i 30 ri •i SCALE:i , TREE PROTECTION FENCIN `[NINE WA —C" - AX. HEIG - /' E S _� E� INN (� WA�L 12-0 TREE PROTECTION FENCING Z// i f ` tl l } �J � 1 I / I i f 1 I J f f� f f 1 -J t f X_ND I;f' ER D N 8 ELOC E I DV/ A/LL/ / TREE PROTECTION FENCING / / ! / SEE PLANS FOR EXACT LAYOUT. SPACE PLANTS AS SPECIFIED IN PLANT LIST OR AS SHOWN. ADJUST SPACING AS NECESSARY OR AS DIRECTED BY LANDSCAPE ARCHITECT. MULCH 2" DEEP IMMEDIATELY AFTER PLANTING AND WATER v THOROUGHLY. e PLANTING PIT. PREPARED SOIL FOR SHRUBS SOIL SURFACE ROUGHENED TO BIND NEW SOIL SHRUB PLANTING DETAIL - In Not To Scale SET TRUNK PLUMB. SEE PLANS FOR EXACT LAYOUT AND SPACING. ARBOR TIES, OR SIMILAR 1-1/2" SQ. OAK STAKES SET 180 DEGREES APART FINISHED GRADE APPLY 2" OF WOOD CHIPS AFTER PLANTING AND WATER THOROUGHLY 4" COMPACTED EARTH WATERING BERM EXISTING GRADE PLANTING PIT, SEE SPECS FOR EXACT REQUIREMENTS, PLANTING SOIL, AND PLANTING SOIL AMENDMENTS. REMOVE BURLAP & STRING FROM TOP 1/3 OF ROOT BALL UNDISTURBED SOIL 2 TREE PLANTING DETAIL C� � Nat To Scale SET SHRUB PLUMB. TOP OF ROOTBALL SHALL NOT BE MORE THAN 1" ABOVE FINISHED GRADE REMOVE BURLAP FROM TOP 1/3 OF ROOTBALL 3" TALL WATERING BERM FINISHED GRADE �•DIA:.�MIIV::•i��i U) w �� I ry > TWO TIMES BALL DIA. (MIN) 1992 3.38 Source. Va. DSWC III - 401 Plate 3.38-2 SEE TREE PLANTING DETAIL FOR STAKING ROOT BALL MODIFIED AS REQUIRED ROUND —TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CENTERED ON THE DOWNHILL SIDE OF THE ROOT BALL FOR 240. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. 4 LAYER OF MULCH. NO MORE THAN 1" OF MULCH ON TOP OF ROOT BALL. 1. 3X WIDEST DIMENSION OF ROOT BALL TREE ON SLOPE @ 25% (4:1 -) to 50% (2:1 Not To Scale County of Albemarle Conservation Plan Checklist —To be placed on Landscape Plans (Handbook, pp 1I1-284-111-29 7 for complete specifications) ORIGINAL SLOPE SHOULD PASS THROUGH THE POINT WHERE THE TRUNK BASE MEETS SUBSTRATE/SOIL PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED. POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. LOOSENED SOIL. DIG AND TURN THE SOIIL TO REDUCE THE COMPACTION TO THE AREA AND DEPTH SHOWN. SLOPE SIDES OF LOOSENED SOIL, ORIGINAL GRADE EXISTING SOIL 1. The following items shall be shown on the plan: Trees to be saved; Limits of clearing (outside dripline of trees to be saved); Location and type,ofprotective fencing; Grade changes requiring tree wells or wails: CQ Proposed trenching or tunneling beyond the limits of clearing. 2. Markings: All trees to be saved shall be marked with print or ribbon at a height clearly visible to equipment operators. Ll No grading shalt begin until the tree marking has been inspected and approved by a County Inspector. 3. Pre -Construction Conference: Tree preservation and protection measures shall be reviewed with the contractor on site. 4. E uC ment O ration and Storage: Heavy equipment, vehicular traffic and storage of construction materials including soil shall not be permitted within the driplines of trees to be saved. 5. Solt Erosion and Stormwater Detention Devices: Such devices shall not adversely affect trees to be saved. 6. Fires: Fires are not permitted within 100 feet of the dripline of trees to be saved„ 7 I I M t A 1.4 oxc ® Toxic materials shall not be stored within 100 feet of the dripline of trees to be saved. 8. Protective Fencing: Trees to be retained within 40 feet of a proposed building or grading activity shall be protected by fencing. Fencing shall be in place and shall be inspected and approved'by a County Inspector prior to grading or construction- *. Tree Wells: El When the ground level must be raised within the dripline of a tree to be saved, a tree well shall be provided and a construction detail submitted for approval. 10. Tree Walls- 0 When the ground level must be lowered within the dripline a tree to be saved, a tree wall shall be provided; and a construction detail submitted for approval. 11. Trenching and Tunneling: C! When trenching is required within the limits of elearing, it shall be done as faraway from the trunks of trees as possible. Tunneling under a large tree shall be considered as an alternative when it is anticipated that necessary trenching will destroy feeder roots. 12. Cleanup: Protective fencing shall be the last items removed during the Final cleanup. 13. Damaged Trees: Damaged trees shall be treated immediately by pruning, fertilization or other methods recommended by a tree specialist. NOTE: IT IS THE EVELOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION 1-11 - � / REQUIREMENTS. 06/13/2018 CONTRACT PURCHASER SIGNATURE (DATE) 5/1/U6 Page 1 of 1 Ij iySTy M. Na. S 183 �'0 ��SS jONAL ��� TREE PROTECTION FENCING (TP CONSERVATION PLAN CHECKLIST Schedule Symbol Label Quantity Manufactur Catalog Description Lamp Number Filename Wattage Light Loss Factor er Number Lamps 6 PHILIPS ECF-S-48L- ECOFORM AREA LED LED 1 ECF-S-48L- 135.1 1 GARDCO 900-NW-G2 ECF-SMALL, 48 LED'S, 900-NW-G2- -4-HIS 4000K CCT, TYPE 4-HIS OPTIC, HOUSE -SIDE 4-HIS.IES A INTERNAL SHIELDING 2 PHILIPS ECF-S-48L- ECOFORM AREA LED LED 1 ECF-S-48L- 135.1 1 GARDCO 900-NW-G2 ECF-SMALL, 48 LED'S, 900-NW-G2- -5 4000K CCT, TYPE 5-HIS 5-HIS.IES OPTIC, NO SHIELD 0 B 7 LITHONIA KBA8-LED- KBA8 WITH 3 LIGHT LED 1 KBA8_LED_ 22.0 1 LIGHTING 12C-530-40 BOARDS (12 LEDs), 530 12C_530_40K C -ASY-MVOLT mA DRIVER, 4000K COLOR TEMP, AND ASYMMETRIC OPTIC _ASY-MVOLT IES N OTE: 1. All pole mount fixtures shall be mounted at a total height of 15' from the finished grade which includes the pole base, unless noted. 2. Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielde to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads! a property in residential or rural areas zoning districts shall not exceed one half footcandle. 3. New free-standing pole mounted light fixtures (and poles) and new wall mounted fixtures shall be a black finish. +0.0 +0.0 +0.0 +0. +0°0 + +0+0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 a* 0 -'8. +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.1 +0.1 +0.1 +0.0 +0.0 +0.0 +0.0 +o.0 +0.0 +0.0 *c +0.0 +0.0 +0.0 +0.0 +0,0 t0.2 +0°0 +0,0 + + +0.0 +0.0 +0.2 +0.0 .0 +0.0 +0.0 +0.0 #0. 0.0 .0 +0.0 +0.0 +0.0 +0.0 + 0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.2 +0.0 +0.0 +0.0 +0°0 +0.0 +0°0 • 0 30 .0 •• Ordering guide Project: Location: Cat.No:� Type: Qty: Notes: The Philips Gardco EcoForm Gen-2 combines economy with performance in an LED area luminaire. Capable of delivering up to 26,400 lumens or more in a compact, Low profile LED luminaire, EcoForm offers a new Level of customer value. EcoForm features an innovative retrofit arm kit, simplifying site conversions to LED by eliminating the need to dritL additional holes in most existing poles. Integral control systems avaitable for further energy savings. example: ECF-S-64L-900-NW-G2-AR-5-120-HIS-MGY Number Drive LED Color- Prefix pfLEps Current Generation Mounting Distribution Voltage Dimming controls Motion sensing Photo -sensing Electrical Luminajre Finish ECF-s 748- -1 oo �1 L ] C �J l � � C� His CJ Ilvw-c2 � ECF-S 32L 530 WW-G2 AR Type2 120 120V DO 0-I0VExternal IMRI3 PCB Fusing Square Pole Textured EcgFonn 32LEDs 530mA WannVJhite Aim Mount 208 208V dimming(byothea)' Integral with Photoconlrol Adapter 2 Type2 Fl Single gK Black siteandarea, (2 modules) 700 3000K,70CRl (standard)' 2-90 Rotated 240 240V DCC Dual Circuiteontrols #3lens, Button" (120,277,347VAC)r included in WH While Small 700mA Generation left90' 277 277V FAWS Field Adjustable" IMR17 TLRDS F2 Double standard RZ Bronze Thefclfowing 1A NW-G2 2-270 Rotated 347 347V SW Interface module Integral g Twist Luck (208,240,480VAC) , product DGY Dark Gray 1050mA Nenral While mounting right270° 480 480V forSiteWise'21 #7lens' Receptacle TS MGY Medium Gray 11A 4000K,70CRI kits must UNV 120-277V LLC2 Integral module lMRO 5P1ns Pole Mount Fusing Terminal Customer specified FPt Single 1200mA Generation be ordered Type3 (54J60Hz) ie with #2tens Pole mounted TLRD7 Block' 3Type 3 RAL Specify spiourafely HVU 347-480V LLC3 hitegralmodule motion sensor' Twist Lock (120,277.341VAC: RPA 48L 900 CW-G2 (See 3.90 RpWled (50/6011z) with #3lens" (see accessories) Receptacle fP2 Double Round Pole optional 48LEDs 900mA Cool While accessuries) left LLC4 Integral g 7PIn" {208,240,460VAC)' Adapter color or RAL (3 modules) 1A 5000K,1OCR1 SF 3.270 Rotated with #4lensr' TLRPC FP3 Canadian Double (fits to3"-39' (ex:RAl7024) CC Custonlcolor IOSOmA Generation Slip Fitter right270' DynaDimmer. Automatic Twist Lock Pult(203,240,480VAQ O.D. pole)'" (Must supply 12A Mount' Type Profile Dimming Receptaclew/ ' HIS colorchip 1200mA (fitsto211e" Photocell' Surge Internal for required 4Type4 CS50 Safety 64L 900 O.O.tenon) Dimming. 7 hours' (tokAstandard) Housing factory quote) 64 LEDs 900mA WS 4-90 Rotated left90` CM50 Median 50% SP2 Increased 2OkA Side Shield' 0modules) 1A Wall mount 4 270 Rotated Dimming, 8 hours' 1050mA with right270' tE59 Economy54% conduit Dimming, 9 hours' fear entry Type DA50 All Night507. permitted 5Type 5,T- Dimming' RAM SW Type 5VJ C530 Safety 30% Retrofit arm AFR Diroming,7hours' mountkit' Auto Front Row CM30 Median 30% AFR-90 Dimming,8 hours' Auto Front Row. CE30 Economy30% Rotated left 90 Dimming, 9 hours' DA30 Ali Night AFR-270 Dimming' Auto Front Row, Rotated right 270' I Available only on 120.208.240. and 277 (or UNV) 8. ECF-IMRI equippedwith out -boarded sensor housing when 13. Available only on 120V and 2T7V 2. Specify Voltage voltage is HVU(347-48OV) 14. Not available with DCC,IMRI3, IMR17, 5W, LLC and CS/CM7CE/DA 3. Not available with 347or480 voltage 9. Mounts to a4'round pole with adapter included for (DynaDirnmer). 4. HIS not available with Type 5 or 5W optics square poles. 15. TLRD5/7 option not available with LLC, PCB, TLRPC or DCC. S. DO is required for LL(R.Dimming leads are supplied through back of 10. Not available with SF and WS. RPAS provided with black Max arming angle 45:. Works with 3 or 5 pin NEMA photocell/dimming luminaire. Must be ordered separately (See accessories page) finish standard Dimming will not be connected to NEMAreceptadeitordering with 6. DCC and LLC2/3/4 not available with any other controls 11. Limited to a maximum of 45 degrees aiming above horizontal DO, CS/CM/CE/DA,IMRIand IMRO. 7. TB not available withD(C 12. SW option is not available with any other control options with the exception of IMR13. IMR17 and SW-IMRO motion response options ECF-S-EcoForm_area_smat[ 03/18 page 1 of 9 LIGHT FIXTURE SPECIFICATION Catalog Number Notes r Type Introduction The KBA8 Bollard is a stylish, fully integrated LED solution for walkways. It features a sleek, modern design and is carefully engineered to provide long-lasting, energy -efficient lighting with a variety of optical and control options for customized performance. With an expected service life of over 20 years of nighttime use and up to 70% in energy savings over comparable 10OW metal halide luminaires, the KBA8 Ballard is a reliable, low -maintenance lighting solution that produces sites that are exceptionally illuminated. e it EXAMPLE: KBA8 LED 16C 700 40K SYM MVOLT DDBXD AC(eSsolt te5 t . €aster nt hw�� euaraa ... MRADU Anchor bolts for KDA8LED' MOD While Striping' )NAXD Natural SDDB Dark aluminum bronze )DBXD Dark 5DWN 'Nhite bronze SDBL Black )BLXD `clack SDNA Natural )DBTXD Textured aluminum dark SDTG Tennis bronze greed )BLBXD Textured SDBR Brlghifed buck SDBUA Dark blue )NATXD Textured MILD Yellow aluminum )WHGXD Textured ,eifute NOTES 1 Only available in the 12C, ASY version. 2 Only available in the 16C, SYM version. 3 Only available with 450 AMBUN version. 4 Not available with ELCVV. S MVOLT driver operates on any lino voltago from 120-277V (50/60 Hz), Specify 120, 208, 240 or 277 options only when ordering with fusing (SF, DF options), or photoconnol (PE option). 6 Not available with 347V. Not available with fusing. Not available with 450 AMBLY4 7 Single fuse (5F) requires 120, 277, or 347 voltage option. Double fuse (OF) requires 208 or 240 voltage option- 8 MRAB U not available with UAB4 option. 9 Striping isavailab!eonly inthe oa!arslisted. �lrl-10 VIA One Liihonia VVay • Conyers, Georgia 30012 • Phone: 600.279.8041 • ,�v mvJth0nia corn 0 2012-2018 Acuity Brands Lighting, Inc. All rights reserved. ° o w U w N W W Z Z W W 0 y[T� 0 cL Q nT I D z � 1= N a N F-- W Q W i t- 01 W J z J O > = W V) F� 0 0 W J W Dr Cq or U � N C/) C/) 'C a1 m Q V (D o E E O O U U 0 C U Cj Q O j� cV 4 1 � O` C7 C:) Date 06/08 20 Scale 1 "=30' Sheet No. C7 OF 9 File No. 16.025 OVAOO i / al ac i / �lc Ma ,' TEf, pt PE�EST LE,PHOE, , (O Al C ' C (,-- I CTIQ T NSF MER ; �b EE S / / `' / t t X ND HQ E U ERD N Sri B ELO /E1 IIWA�L/ NOTE: THIS PAGE SHOWN FOR THE SAKE OF COMPLETION ONLY. NO CHANGES TO THE DRAINAGE AREA OR RUNOFF COEFFICIENT RESULTED FROM THE REVISED PEDESTRIAN PATH LOCATION. 90