HomeMy WebLinkAboutSDP201800003 Plan - Approved Letter of Revision 2 2020-08-21LETTER OF REVISION #2 FOR
LEGEND
EXIST NEW DESCRIPTION
16, -rC x 125 TC TOP OF CURB ELEVATION
W X 125 SPOT ELEVATION
16, TW x 125 TW TOP OF WALL ELEVATION
161BW x 125BW BOTTOM OF WALL ELEVATION
BENCHMARK
—
STORM SEWER
----
RQ
ROOF DRAIN
—�
—
SEWER LINE
WATER LINE
----
GAS
GAS LINE
c
CHE
OVERHEAD ELECTRIC WIRE
UGE
UNDERGROUND ELECTRIC
. -
GHT
OVERHEAD TELEPHONE LINE
---�--ae
UGT
UNDERGROUND TELEPHONE LINE
— — — —
GAS CONDUIT
DRAIN INLET (DI)
O
STORM/SANITARY MANHOLE
E
C
PLUG
OW
®N
WATER VALVE & BOX
.
FIRE HYDRANT
WATER METER
LIGHT POI F
M�
UTILITY POLE
PROPERTY LINE
ADJACENT PROPERTY LINE
------- VACATED PROPERTY LINE
-c — BUILDING SETBACK
— PARKING SETBACK
SANITARY EASEMENT
CONSTRUCTION EASEMENT
DRAINAGE EASEMENT
�--®- ----- - �-- UTILITY EASEMENT
----•----- - WATER EASEMENT
- -- - - - - - ACCESS EASEMENT
-�- - ----- STORM DRAINAGE EASEMENT
---- GAS LINE EASEMENT
LANDSCAPING EASEMENT
TREE LINE
- ---- ---� FENCE
STREAM
312 12 INTERVAL CONTOUR
300— oo INDEX CONTOUR
CG-2
Cc-2
STANDARD 6"
CURB
CG--6
CG-6
COMBINATION
6" CURB & GUTTER
CONCRETE PAVEMENT / SIDEWALK
RIPRAP
ASPHALT
GRASS
EC-2 MATTING
EC-3 MATTING
•,•°°a°,•°•°
WETLAND
to
10
PARKING COUNT
CROSSWALK
HANDICAP ACCESSIBLE AISLE
ZFN
CG-12
6%
clv
HANDICAP PARKING
HAN5EN ROAD CHURCH
TMP 07800-00-00-O73AB, SDP 201600003
RIVANNA DISTRICT, ALBEMARLE COUNTY, VIRGINIA
SHEET C2
IMAGE PROVIDED BY GOOGLE MAPS
-T X
Z-SHZTC I -COVER 5f1EE
5h1EET C3 -EXISTING CONDITIONS * DEMO
SHEET C4 - EXISTING EASEMENTS
CIEC - VIEW / 51GFiT DISTANCE LINES
- SITE PLAN
SHEETS C3 * C4rSNFF=T - GPADING PLAN
SHEETS C5 � CG - AN S-CAPINC2 PL N
H T S
SHEET C7 I - LIGHTING PLAN
SHEETS C8 * C9 SNFFT ' `' - DRAINAGE MAP
- EI LES AND DETAILS
SHEET C 14 - WATEP. � SEWEK PKOEI LES AND DETAILS
SHEET C 15 - SITE DETAILS
SHEET C I C- 19 - RETAINING WALL DETAILS
SIGNATURE BLOCK
CURRENT DEVELOPMENT PLANNER
CURRENT DEVELOPMENT ENGINEER
ALBEMARLE COUNTY SERVICE AUTHORITY
FIRE OFFICIAL
ARCHITECTURAL REVIEW BOARD
BUILDING OFFICIAL
OWNER / DEVELOPER
Owner: Point Church
1428 Greenbrier Place
Charlottesville VA, 22901
Developer: Core Real Estate and Development
195 Riverbend Drive
Charlottesville VA, 22911
ZONING
Planned Development Mixed Commercial
Entrance Corridor (EC)
Steep Slopes - Managed
Parcel, Owner Impacted by Site Plan:
78-73AA, Albemarle Land LLC
78-7381+, Hansen Road Professional Center LLC et al.
78-3A6+, Virginia School Boards Association et al.
Original Approved ZMA 1998-20
Amended ZMA 2002-08
ZMA 2018-2
Owner Subject to Four Party Road Improvement
Agreement dated 09/21/1998, Deed Book 1899 Pg. 402
LEGAL REFERENCE
TMP 07800-00-00-073AB - DB 4416 PG 460
DB 4786/17 PLAT
BENCHMARK
Benchmark for topographic survey is the top of a sewer
manhole located northeast of the site.
Elev. = 536.95'
Datum: NAVD88
SOURCE OF
BOUNDARY & TOPO
Boundary & topographic survey information provided by.
Commonwealth Land Surveying
319 Rio Road W
Charlottesville, VA 22901
2/6/17
Additional topography provided by Albemarle County GIS
BUILDING HEIGHT
Maximum: 65'
Floors above 40' or the third story shall be stepped back
a minimum of 15' from the front of the building.
Proposed Height:
(Church) 34'
SETBACKS
Front Max: 30' from right of way or exterior edge of
sidewalk if outside right of way
Front Min: 10' from right of way or exterior edge of
sidewalk if outside right of way
*Note: Setbacks shown on the plans are measured from
the private street easement from both Rolkin Road and
Hansen Road
Side & Rear: Adjacent to RA district boundary, residential,
or Monticello Historic District
Building Min. 50', Max. None
Parking Min. 20', Max. None
Adjacent to commercial or industrial
Structure shall be constructed and separated in
accordance with current edition of Building Code.
EXISTING USE
Vacant Land
PROPOSED USE
28,246 SF Church with Associated Parking
FLOOD ZONE
According to the FEMA Flood Insurance Rate Map, effective date February 4, 2005
(Community Panel 51003CO289D), this property does not lie within the Zone AE
100-year flood plain.
WATER & SANITARY SERVICES
All water and sanitary sewer services are to be provided by Albemarle County
Service Authority.
Backflow prevention measures shall be installed in accordance with ACSA
Standards.
WATERSHED
This site is not located within a water supply protection area.
LIGHTING
Proposed lighting and photometrics are included on Sheet C10.
LAND USE SCHEDULE
EXISTING
Road
Sidewalk
Open space
Area
29,833 SF
10,839 SF
226,863 SF
%
11.15%
4.05%
84.80%
Total=
267,535 SF (6.14 ac.)
PROPOSED
Area
%
Building
11,402 SF
8.19%
Pavement
109,816 SF
78.91 %
Walkways
17,948 SF
12.90%
Impervious area
139,166 SF
52.02%
Open space
128,369 SF
47.98.%
Total=
267,535 SF (6.14 ac.)
SIGNS
All signs shall conform with the MUTCD Guidelines.
ITE TRIP COUNT
Trip Generation Manual, loth Edition
AM
PM
Use Description
ITE
Qty
in
out
Total
in
out
Total
Church Sunday Peak Hour
560
28246 sf
142
153
295
Church Weekday
560
128246sf
10
8
18
16
10
25
REOU I RED IMPROVEMENTS
1. In the event that the owner of the adjacent
property TMP 78-73A1, which holds a stormwater
easement across TMP 78-73AB as shown on this site
plan, were to damage or destroy any of the required
improvements shown on this site plan (including but
not limited to parking areas, access aisles, curb and
gutter, retaining walls, landscaping, as well as storm
drain pipes and structures) the owner of TMP
78-73AB would be fully responsible for the
�se
n o e im eme or i olation of
plan..poncompletion of path, its location must be
surveyed and a 6 ft access easement must be
recorded around its exact location, along with a
maintenance agreement, prior to obtaining the
certificate of occupancy.
Lo4f 4-,-7
Submittal Type
Reviewed and Approved by the
Commur ty evelop ent Department
Date ��
File# � 20 bc�b �_ L D ✓:
NOTE:
1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOWN.
VIRGINIA DEPARTMENT OF TRANSPORATION
atureAz, � �{
(4 S}
/ 1
J �
i
r�
/
/
/ e
/
EX ND III*,
ST /
ELO �,E WWA� j
TREE PROTECTION FENCING /
TREE PROTECTION FENCIN
ttNtNG WA- -C` " AX�IEIG
XMIX
r
� � r
� r
r
!
r
30
SCALE: 1 " _
0 30 BO 90
PROPOSED LANDSCAPE SCHEDULE
Plant
Symbol
Planting Type
Botanical Name
Common Name
Min
Cal./Height
Quantity
Total
Height(ft)
CaSFpy
Total
Canopy
Plan
Reference
in 10 Yrs
SF
Large Deciduous Tree
Quercus alba
White Oak
2.5"
25
22
243
6075
Large Deciduous Tree
Quercus bicolor
Swamp White Oak
2.5"
25
20
299
7475
Large Deciduous Tree
Fagus grandifolia
American Beech
2.5"
4
20
227
908
Large Deciduous Tree
Acer x freemanii
Autumn Blaze
Maple
2.5"
8
20
397
3176
0
Large Deciduous Tree
Ulmus americans cvs.
American Elm
Valley Forge'
2.5'
9
15
397
3573
Large Deciduous Tree
Liquidambar styraciflua
Sweetgum
2.5"
8
15
249
1992
Broadleof Evergreen
Magnolia grandiflora
Southern Magnolia
3-4' Ht.
12
14
54
648
.j
Broadleaf Evergreen
Juniperus virginiana
Eastern Redcedar
3-4' Ht.
12
14
16
192
{
Broadleaf Evergreen
Pinus strobus
White Pine
2.5"
26
24
118
3068
Evergreen Tree
Tsuga canadensis
Eastern Hemlock
2.5"
5
10
16
80
S?i�s
Small Flowering Tree
Magnolia virginiana
Sweet Ba y
Magnolia
6'
26
10
113
2938
Small Flowering Tree
Cersis canadensis
Eastern Redbud
6'
15
10
124
1860
Broadleaf Evergreen Shrub
Magnolia grandiflora
'Little
Little Gem
Magnolia
6'
60
22
82
4920
Gem'
Broadleaf Evergreen Shrub
Myrica penslyvanica
Northern Bayberry
24" Ht.
60
3
18
1080
Broadleaf Evergreen Shrub
Ilex vomitoria
Youpon Holly
24" Ht.
60
3
16
960
Deciduous Shrub
Fathergilla gardenii
Dwarf Fathergilla
24" Ht.
60
0
Low Maintenance Ground
Cover 1
Southeast Native
Grass Seed Mix
.866ac
Low Maintenance Ground
Cover 2
Southeast
Wildflower Seed Mix
101b
TOTAL
SF:
38945
LANDSCAPING REQUIRED:
SITE REQUIREMENT (32.7.9.8): 10% CANOPY REQUIRED.
SITE AREA 267,535 SF x 10% = 26,754 SF
CANOPY REQUIRED: 26,754 SF
CANOPY PROVIDED: 38,945 SF CANOPY PROVIDED
STREET TREES (32.7.9.5): LARGE SHADE TREES (2.5" CAL.) — 40' O.C. PARALLEL TO ROAD
HANSEN RD — 396 LF/40 = 10
ROLKIN RD — 1,320 LF/40 = 33
ROLKIN RD (OFF PROPERTY) — 428 LF/40 = 11
REQUIRED 54 LARGE SHADE TREES
PROVIDED 54 LARGE SHADE TREES
11 ALONG HANSEN RD & 45 ALONG ROLKIN RD.
NOTE: TREES OCCASIONALLY NOT 40' O.C. DUE TO SITE RESTRAINTS SUCH AS 'SIGHT DISTANCE
TRIANGLE' AND EASEMENTS. THREE PRESERVED TREES ALONG ROLKIN COUNTED TOWARD
STREET TREE CALCULATION.
INTERIOR/PARKING LANDSCAPE (32.7.9.6): 5% OF PARKING PAVED AREA, 46,281 SF X .05 = 2,314.05 SF
REQUIRED 2,314.05 SF OF LANDSCAPED AREA
PROVIDED: 9,106 SF OF LANDSCAPED AREA
LARGE SHADE TREES (2.5" CAL.)
160 PARKING SPACES (16 / 10 = 16)
REQUIRED 16 LARGE SHADE TREES
PRQVIDED:16 LARGE SHADE TREES
SCREENING SHRUBS — AS NECESSARY TO MINIMIZE APPEARANCE OF PARKING & AND RETAINING WALLS
NOTES:
1. Contractor to apply 4' diameter by 2-5" mulch bedding around all proposed trees, and mulch bedding around
shrubs.
2. All other landscaped areas shall be sodded.
3. All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the
topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health
of the plant.
4. All landscaping and screening shall be maintained in a healthy condition by the current owner or property
1�
owners' association and replaced when necessary. Replacement material shall comply with the approved
w
landscape plan.
5. All new planting shown on the plan will be completed after building and road construction to avoid tree planting
damage.
6. All disturbed slopes 3:1 or steeper to have low maintenance ground cover.
f
7. Any existing tree proposed to remain shall be replaced in kind if negatively impacted by improvements
/
associated with this project.
MAINTENANCE:
* LOW MAINTENANCE GROUND COVER —The best time of year to mow is during the fall through late winter. Mow
,
on a three—year cycle where 1/3 of the area is mowed each year. Do not mow during the spring or summer
months because of the nesting season. When mowing, cut grass no lower than 6 inches and allow stubble to
remain until spring to help insulate plant roots and provide cover for wildlife. If native warm —season grasses are
/
cut lower than 6 inches during the active growing season, the stand will be reduced significantly.
/
— PLANTING GUIDE 'AMERICUS'INDIANGRASS Sorghastrum nutans USDA—NRCS Jimmy Carter PMC
Americus, Georgia
SEED MIXES:}
SOUTHEAST NATIVE GRASS SEED MIX (AMERICAN MEADOWS INC.) — Mix the following seeds:-
• Kentucky 31 Fescue (Festuca arundinacea) — 100 lb/acre, Red Top Grass (Agrostis gigantea) — 20 Ib/acre, Virginia
Wildrye (Elymus virginicus) — 20 lb/acre, Little Bluestein Grass (Schizachyrium scoporium) — 20 lb/acre, Purpletop
(Tridens flavus) — 20 lb/acre, and Broomsedge (Andropogon virginicus) — 20 lb/acre, Indian Grass (Sorghastrum nutans)
— 20 lb/acre.
SOUTHEAST WILDFLOWER SEED MIX (AMERICAN MEADOWS INC.) — The mixture includes:
30 i 30 ri •i
SCALE:i ,
TREE PROTECTION FENCIN
`[NINE WA —C" - AX. HEIG - /'
E S _� E� INN (� WA�L
12-0
TREE PROTECTION FENCING
Z// i f
`
tl
l
}
�J
�
1
I
/
I
i
f
1
I
J
f
f�
f f
1
-J
t f X_ND I;f'
ER D N
8
ELOC E I DV/ A/LL/
/ TREE PROTECTION FENCING / /
! /
SEE PLANS FOR EXACT LAYOUT. SPACE
PLANTS AS SPECIFIED IN PLANT LIST OR
AS SHOWN. ADJUST SPACING AS
NECESSARY OR AS DIRECTED BY
LANDSCAPE ARCHITECT.
MULCH 2" DEEP IMMEDIATELY
AFTER PLANTING AND WATER v
THOROUGHLY.
e
PLANTING PIT.
PREPARED SOIL FOR SHRUBS
SOIL SURFACE ROUGHENED
TO BIND NEW SOIL
SHRUB PLANTING DETAIL
-
In Not To Scale
SET TRUNK PLUMB. SEE PLANS
FOR EXACT LAYOUT AND
SPACING.
ARBOR TIES, OR SIMILAR
1-1/2" SQ. OAK STAKES
SET 180 DEGREES APART
FINISHED GRADE
APPLY 2" OF WOOD CHIPS AFTER
PLANTING AND WATER THOROUGHLY
4" COMPACTED EARTH
WATERING BERM
EXISTING GRADE
PLANTING PIT, SEE SPECS FOR EXACT
REQUIREMENTS, PLANTING SOIL, AND
PLANTING SOIL AMENDMENTS.
REMOVE BURLAP & STRING FROM
TOP 1/3 OF ROOT BALL
UNDISTURBED SOIL
2 TREE PLANTING DETAIL
C� � Nat To Scale
SET SHRUB PLUMB. TOP OF
ROOTBALL SHALL NOT BE MORE THAN
1" ABOVE FINISHED GRADE
REMOVE BURLAP FROM TOP
1/3 OF ROOTBALL
3" TALL WATERING BERM
FINISHED GRADE
�•DIA:.�MIIV::•i��i
U)
w
��
I
ry
>
TWO TIMES
BALL DIA. (MIN)
1992 3.38
Source. Va. DSWC
III - 401
Plate 3.38-2
SEE TREE PLANTING DETAIL
FOR STAKING
ROOT BALL MODIFIED AS
REQUIRED
ROUND —TOPPED SOIL
BERM 4" HIGH X 8" WIDE
ABOVE ROOT BALL SURFACE SHALL
BE CENTERED ON THE DOWNHILL
SIDE OF THE ROOT BALL FOR 240.
BERM SHALL BEGIN AT ROOT BALL
PERIPHERY.
4 LAYER OF MULCH. NO MORE THAN 1"
OF MULCH ON TOP OF ROOT BALL.
1. 3X WIDEST DIMENSION OF ROOT BALL
TREE ON SLOPE @ 25% (4:1 -) to 50% (2:1
Not To Scale
County of Albemarle
Conservation Plan Checklist —To be placed on Landscape Plans
(Handbook, pp 1I1-284-111-29 7 for complete specifications)
ORIGINAL SLOPE SHOULD PASS
THROUGH THE POINT WHERE THE
TRUNK BASE MEETS SUBSTRATE/SOIL
PRIOR TO MULCHING, LIGHTLY TAMP
SOIL AROUND THE ROOT BALL IN 6"
LIFTS TO BRACE TREE. DO NOT OVER
COMPACT. WHEN THE PLANTING
HOLE HAS BEEN BACKFILLED. POUR
WATER AROUND THE ROOT BALL TO
SETTLE THE SOIL.
LOOSENED SOIL. DIG AND TURN
THE SOIIL TO REDUCE THE
COMPACTION TO THE AREA AND
DEPTH SHOWN.
SLOPE SIDES OF LOOSENED SOIL,
ORIGINAL GRADE
EXISTING SOIL
1. The following items shall be shown on the plan:
Trees to be saved;
Limits of clearing (outside dripline of trees to be saved);
Location and type,ofprotective fencing;
Grade changes requiring tree wells or wails:
CQ Proposed trenching or tunneling beyond the limits of clearing.
2. Markings:
All trees to be saved shall be marked with print or ribbon at a height clearly visible to equipment operators.
Ll No grading shalt begin until the tree marking has been inspected and approved by a County Inspector.
3. Pre -Construction Conference:
Tree preservation and protection measures shall be reviewed with the contractor on site.
4. E uC ment O ration and Storage:
Heavy equipment, vehicular traffic and storage of construction materials including soil shall not be permitted within the driplines of trees
to be saved.
5. Solt Erosion and Stormwater Detention Devices:
Such devices shall not adversely affect trees to be saved.
6. Fires:
Fires are not permitted within 100 feet of the dripline of trees to be saved„
7 I I M t A 1.4
oxc
® Toxic materials shall not be stored within 100 feet of the dripline of trees to be saved.
8. Protective Fencing:
Trees to be retained within 40 feet of a proposed building or grading activity shall be protected by fencing.
Fencing shall be in place and shall be inspected and approved'by a County Inspector prior to grading or construction-
*. Tree Wells:
El When the ground level must be raised within the dripline of a tree to be saved, a tree well shall be provided and a construction detail
submitted for approval.
10. Tree Walls-
0 When the ground level must be lowered within the dripline a tree to be saved, a tree wall shall be provided; and a construction detail
submitted for approval.
11. Trenching and Tunneling:
C! When trenching is required within the limits of elearing, it shall be done as faraway from the trunks of trees as possible. Tunneling
under a large tree shall be considered as an alternative when it is anticipated that necessary trenching will destroy feeder roots.
12. Cleanup:
Protective fencing shall be the last items removed during the Final cleanup.
13. Damaged Trees:
Damaged trees shall be treated immediately by pruning, fertilization or other methods recommended by a tree specialist.
NOTE: IT IS THE EVELOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION
1-11 - � / REQUIREMENTS.
06/13/2018
CONTRACT PURCHASER SIGNATURE (DATE)
5/1/U6 Page 1 of 1
Ij iySTy M.
Na. S 183
�'0
��SS jONAL ���
TREE PROTECTION FENCING (TP
CONSERVATION PLAN CHECKLIST
Schedule
Symbol
Label
Quantity
Manufactur
Catalog
Description
Lamp
Number
Filename
Wattage
Light Loss
Factor
er
Number
Lamps
6
PHILIPS
ECF-S-48L-
ECOFORM AREA LED
LED
1
ECF-S-48L-
135.1
1
GARDCO
900-NW-G2
ECF-SMALL, 48 LED'S,
900-NW-G2-
-4-HIS
4000K CCT, TYPE 4-HIS
OPTIC, HOUSE -SIDE
4-HIS.IES
A
INTERNAL SHIELDING
2
PHILIPS
ECF-S-48L-
ECOFORM AREA LED
LED
1
ECF-S-48L-
135.1
1
GARDCO
900-NW-G2
ECF-SMALL, 48 LED'S,
900-NW-G2-
-5
4000K CCT, TYPE 5-HIS
5-HIS.IES
OPTIC, NO SHIELD
0
B
7
LITHONIA
KBA8-LED-
KBA8 WITH 3 LIGHT
LED
1
KBA8_LED_
22.0
1
LIGHTING
12C-530-40
BOARDS (12 LEDs), 530
12C_530_40K
C
-ASY-MVOLT
mA DRIVER, 4000K
COLOR TEMP, AND
ASYMMETRIC OPTIC
_ASY-MVOLT
IES
N OTE:
1. All pole mount fixtures shall be mounted at a total height of 15' from the finished grade which includes the pole base, unless noted.
2. Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielde
to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads! a
property in residential or rural areas zoning districts shall not exceed one half footcandle.
3. New free-standing pole mounted light fixtures (and poles) and new wall mounted fixtures shall be a black finish.
+0.0 +0.0 +0.0 +0. +0°0 +
+0+0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0
a* 0 -'8. +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0 +0.0
+0.1 +0.1 +0.1 +0.0 +0.0 +0.0 +0.0 +o.0 +0.0 +0.0
*c +0.0 +0.0
+0.0 +0.0 +0,0
t0.2 +0°0 +0,0 + + +0.0
+0.0
+0.2
+0.0
.0
+0.0
+0.0
+0.0
#0.
0.0
.0
+0.0 +0.0
+0.0
+0.0
+
0.0
+0.0
+0.0 +0.0
+0.0
+0.0
+0.2
+0.0
+0.0
+0.0 +0°0
+0.0
+0°0
• 0 30 .0 ••
Ordering guide
Project:
Location:
Cat.No:�
Type:
Qty:
Notes:
The Philips Gardco EcoForm Gen-2 combines economy with performance in an LED
area luminaire. Capable of delivering up to 26,400 lumens or more in a compact,
Low profile LED luminaire, EcoForm offers a new Level of customer value. EcoForm
features an innovative retrofit arm kit, simplifying site conversions to LED by
eliminating the need to dritL additional holes in most existing poles. Integral control
systems avaitable for further energy savings.
example: ECF-S-64L-900-NW-G2-AR-5-120-HIS-MGY
Number
Drive
LED Color-
Prefix
pfLEps
Current
Generation
Mounting
Distribution
Voltage
Dimming controls
Motion sensing
Photo -sensing
Electrical
Luminajre
Finish
ECF-s
748- -1
oo
�1
L ]
C �J
l �
�
C�
His
CJ
Ilvw-c2
�
ECF-S
32L
530
WW-G2
AR
Type2
120 120V
DO 0-I0VExternal
IMRI3
PCB
Fusing
Square Pole
Textured
EcgFonn
32LEDs
530mA
WannVJhite
Aim Mount
208 208V
dimming(byothea)'
Integral with
Photoconlrol
Adapter
2 Type2
Fl Single
gK Black
siteandarea,
(2 modules)
700
3000K,70CRl
(standard)'
2-90 Rotated
240 240V
DCC Dual Circuiteontrols
#3lens,
Button"
(120,277,347VAC)r
included in
WH While
Small
700mA
Generation
left90'
277 277V
FAWS Field Adjustable"
IMR17
TLRDS
F2 Double
standard
RZ Bronze
Thefclfowing
1A
NW-G2
2-270 Rotated
347 347V
SW Interface module
Integral
g
Twist Luck
(208,240,480VAC) ,
product
DGY Dark Gray
1050mA
Nenral While
mounting
right270°
480 480V
forSiteWise'21
#7lens'
Receptacle
TS
MGY Medium Gray
11A
4000K,70CRI
kits must
UNV 120-277V
LLC2 Integral module
lMRO
5P1ns
Pole Mount Fusing
Terminal
Customer specified
FPt Single
1200mA
Generation
be ordered
Type3
(54J60Hz)
ie
with #2tens
Pole mounted
TLRD7
Block'
3Type 3
RAL Specify
spiourafely
HVU 347-480V
LLC3 hitegralmodule
motion sensor'
Twist Lock
(120,277.341VAC:
RPA
48L
900
CW-G2
(See
3.90 RpWled
(50/6011z)
with #3lens"
(see accessories)
Receptacle
fP2 Double
Round Pole
optional
48LEDs
900mA
Cool While
accessuries)
left
LLC4 Integral
g
7PIn"
{208,240,460VAC)'
Adapter
color or RAL
(3 modules)
1A
5000K,1OCR1
SF
3.270 Rotated
with #4lensr'
TLRPC
FP3 Canadian Double
(fits to3"-39'
(ex:RAl7024)
CC Custonlcolor
IOSOmA
Generation
Slip Fitter
right270'
DynaDimmer. Automatic
Twist Lock
Pult(203,240,480VAQ
O.D. pole)'"
(Must supply
12A
Mount'
Type
Profile Dimming
Receptaclew/
'
HIS
colorchip
1200mA
(fitsto211e"
Photocell'
Surge
Internal
for required
4Type4
CS50 Safety
64L
900
O.O.tenon)
Dimming. 7 hours'
(tokAstandard)
Housing
factory quote)
64 LEDs
900mA
WS
4-90 Rotated
left90`
CM50 Median 50%
SP2 Increased 2OkA
Side Shield'
0modules)
1A
Wall mount
4 270 Rotated
Dimming, 8 hours'
1050mA
with
right270'
tE59 Economy54%
conduit
Dimming, 9 hours'
fear entry
Type
DA50 All Night507.
permitted
5Type 5,T-
Dimming'
RAM
SW Type 5VJ
C530 Safety 30%
Retrofit arm
AFR
Diroming,7hours'
mountkit'
Auto Front Row
CM30 Median 30%
AFR-90
Dimming,8 hours'
Auto Front Row.
CE30 Economy30%
Rotated left 90
Dimming, 9 hours'
DA30 Ali Night
AFR-270
Dimming'
Auto Front Row,
Rotated right
270'
I Available only on 120.208.240. and 277 (or UNV)
8. ECF-IMRI equippedwith out -boarded sensor housing when
13. Available only on 120V and 2T7V
2. Specify Voltage
voltage is HVU(347-48OV)
14. Not available with DCC,IMRI3, IMR17, 5W, LLC and CS/CM7CE/DA
3. Not available with 347or480 voltage
9. Mounts to a4'round pole with adapter included for
(DynaDirnmer).
4. HIS not available with Type 5 or 5W optics
square poles.
15. TLRD5/7 option not available with LLC, PCB, TLRPC or DCC.
S. DO is required for LL(R.Dimming leads are supplied through back of
10. Not available with SF and WS. RPAS provided with black
Max arming angle 45:. Works with 3 or 5 pin NEMA photocell/dimming
luminaire. Must be ordered separately (See accessories page)
finish standard
Dimming will not be connected to NEMAreceptadeitordering with
6. DCC and LLC2/3/4 not available with any other controls
11. Limited to a maximum of 45 degrees aiming above horizontal
DO, CS/CM/CE/DA,IMRIand IMRO.
7. TB not available withD(C
12. SW option is not available with any other control options with the
exception of IMR13. IMR17 and SW-IMRO motion response options
ECF-S-EcoForm_area_smat[ 03/18 page 1 of 9
LIGHT FIXTURE SPECIFICATION
Catalog
Number
Notes
r Type
Introduction
The KBA8 Bollard is a stylish, fully integrated
LED solution for walkways. It features a sleek,
modern design and is carefully engineered to
provide long-lasting, energy -efficient lighting
with a variety of optical and control options for
customized performance.
With an expected service life of over 20 years of
nighttime use and up to 70% in energy savings
over comparable 10OW metal halide luminaires,
the KBA8 Ballard is a reliable, low -maintenance
lighting solution that produces sites that are
exceptionally illuminated.
e it EXAMPLE: KBA8 LED 16C 700 40K SYM MVOLT DDBXD
AC(eSsolt te5 t
. €aster nt hw�� euaraa ...
MRADU Anchor bolts for KDA8LED'
MOD While Striping'
)NAXD Natural SDDB Dark
aluminum
bronze
)DBXD
Dark
5DWN
'Nhite
bronze
SDBL
Black
)BLXD
`clack
SDNA
Natural
)DBTXD
Textured
aluminum
dark
SDTG
Tennis
bronze
greed
)BLBXD
Textured
SDBR
Brlghifed
buck
SDBUA
Dark blue
)NATXD
Textured
MILD
Yellow
aluminum
)WHGXD
Textured
,eifute
NOTES
1 Only available in the 12C, ASY version.
2 Only available in the 16C, SYM version.
3 Only available with 450 AMBUN version.
4 Not available with ELCVV.
S MVOLT driver operates on any lino voltago from 120-277V (50/60
Hz), Specify 120, 208, 240 or 277 options only when ordering with
fusing (SF, DF options), or photoconnol (PE option).
6 Not available with 347V. Not available with fusing. Not available
with 450 AMBLY4
7 Single fuse (5F) requires 120, 277, or 347 voltage option. Double
fuse (OF) requires 208 or 240 voltage option-
8 MRAB U not available with UAB4 option.
9 Striping isavailab!eonly inthe oa!arslisted.
�lrl-10 VIA One Liihonia VVay • Conyers, Georgia 30012 • Phone: 600.279.8041 • ,�v mvJth0nia corn
0 2012-2018 Acuity Brands Lighting, Inc. All rights reserved.
° o
w U
w N W
W
Z
Z
W
W 0
y[T� 0 cL
Q nT I
D z
� 1=
N
a
N
F--
W Q
W i
t-
01 W
J
z J
O >
= W
V) F�
0 0
W J
W Dr
Cq
or U
� N
C/) C/)
'C a1 m
Q V (D
o E E
O O
U U
0 C
U Cj
Q O
j� cV 4
1 � O`
C7 C:)
Date
06/08 20
Scale
1 "=30'
Sheet No.
C7 OF 9
File No.
16.025
OVAOO
i
/
al
ac
i /
�lc
Ma
,' TEf, pt
PE�EST
LE,PHOE,
,
(O
Al
C '
C (,--
I CTIQ
T NSF MER ; �b
EE
S
/
/ `'
/ t t
X ND HQ E
U ERD N
Sri B
ELO /E1 IIWA�L/
NOTE:
THIS PAGE SHOWN FOR THE SAKE OF
COMPLETION ONLY. NO CHANGES TO THE
DRAINAGE AREA OR RUNOFF COEFFICIENT
RESULTED FROM THE REVISED PEDESTRIAN
PATH LOCATION.
90