NOTICE TO COMPLY
Hand delivered
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902
434 296-5832
Project: WP0201800069
Oak Forest Pump Station Abandonment Project - VESCP
Operator/Contractor: Linco Inc
ALBEMARLE COUNTY SERVICE AUTHORITY
Issued Date: 8/25/2020
Under section § 17-900 of the Albemarle County Code, this is your NOTICE TO COMPLY with
the requirements of the Land Disturbance Permit (or Agreement in Lieu of a Plan) for the
referenced project and to immediately take corrective measures to address erosion and sediment
control deficiencies on this property. This Notice to Comply is being issued because of the
following deficiencies:
Deficiency: Project has been dormant for longer than 14 days. Temporary stabilizing is needed
Corrective Action: Seed and straw mulch as required by the approved plan and VESCH manual
Deficiency: See comment and photo item 30
Corrective Action: Seed and straw mulch as required to reduce erosion of the slope.
Deficiency: Silt fence observed at time of visit to be under pressure from sediment buildup and
location related to proximity of the toe of fill.
Corrective Action: Remove all buildup from the silt fence, maintain as required, and remove silt
fence from toe. Silt fence is to have a minimum of 6 foot free space between it and the area of
disturbance.
Deficiency: Observed failing measures that will allow downstream damage
Corrective Action: Make corrections necessary to protect downstream properties
Deficiency: None observed at time of visit
Corrective Action: Ensure there is a practice in place.
Deficiency: None observed at the time of inspection
Corrective Action: If there will be a fuel tank onsite or any storage of petroleum, it must be
within a lined containment area.
Deficiency: None observed at time of inspection
Corrective Action: No wash rack or water observed. Install a containment for wash water and
ensure there is a rack and high pressure wash available
Deficiency: None observed, clear evidence of concrete wash directly on the ground.
Corrective Action: Install proper concrete washout.
Deficiency: Observed trash outside of a proper receptacle
Corrective Action: Cleanup all trash and contain to a protected receptacle
Deficiency: See item 54 photo and description
Corrective Action: Fuels and petroleum waste must be within a lined containment area for proper
disposal, as per manufacturer specifications.
Unless subsequently amended in writing by this office, it is expected all of these corrective
measures will be completed by.
Re -inspection of this notice to verify corrective measures will incur a $150 for land disturbing under
VESCP and single-family dwelling units (§ 17-207) or a $250 fee for land disturbing under VSMP (§ 17-
208). Failure to take effective corrective measures will result in a Stop Work Order upon re -inspection.
County Inspector Name: Geoff Elsie
County Inspector Phone Number: (434) 296-5832
orA1.4 Inspection Result: Notice to Comply
Ljk GI'.�ti�
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902-4596
Phone (434) 296-5832 Fax (434) 972-4126
VSMP/VESCP PERMIT SITE INSPECTION REPORT
Project Name:
Oak Forest Pump Station Abandonment
Project - VESCP
project/WPO Number:
WP0201800069
TMP:
061W10000000A0
DEQ Permit Number (if
applicable):
n/a
Project Operator:
Linco Inc
Operator Telephone #:
(540) 949-0370
Project Contact:
ALBEMARLE COUNTY SERVICE
AUTHORITY
Contact Telephone #:
(434) 977-4511
Contact E-Mail:
jlynn@serviceauthority.org
Qualified Personnel (QP):
Adam L. Critzer
Inspector:
Geoff Elsie
Weather (Wet/Dry/Rain):
Clear sunny
Disturbed Acreage:
Inspection Date & Time:
8/25/2020 1:00:00 PM
Single -Family:
Stage of Construction: Grading
Re -Inspection: No
COVERAGE & POSTING REQUIREMENTS
Compliant?
Reviewed during re -inspection? No
Comments/Description
1
Construction site has permit coverage? (Va. Code §62.1- 44.15:34.A)
(9VAC25-870-31 0)(Al b. Co. Code §17-300, 17-302)
2
A copy of the notice of coverage letter is posted conspicuously near the
main entrance of the construction activity? (CGP Part II.C)
Notice of the location of the SWPPP is posted near the site's entrance, if
3
applicable, and information for public access is provided? (9VAC25-870-
54.G)(CGP Part II D.2 & 3)
SWPPP AVAILABILITY AND CONTENTS
Compliant? Reviewed during re -inspection? No
Comments/Description
4
The SWPPP is on -site or made available during the inspection? (CGP
Part II D.1 & 2)(9VAC25-870-54.G)
5
The SWPPP contains a signed copy of the registration statement?
(CGP Part II A.1.a)
6
The SWPPP includes, upon receipt, a copy of the notice of coverage
letter and the CGP? (CGP Part II A.1.b & c)
The SWPPP includes a narrative description of the nature of the
7
construction activity, including the function of the project? (CGP Part II
A.1.d)
The SWPPP includes a legible site plan identifying all appropriate
8
measures and that includes the locations of support activities and the
onsite rain gauge, when applicable? (CGP Part II A.1.e(1-7))
Page 1 of 5
9
The SWPPP contains the name, phone number and qualifications of
"Qualified Personnel" conducting inspections? (CGP Part II A.6)
10
The SWPPP contains an approved erosion and sediment control plan?
(9VAC25-870-54.B)(CGP Part II.A.2)
The SWPPP contains an approved stormwater management plan or an
11
existing construction site has a stormwater management plan that
ensures compliance with the water quality and quantity requirements?
(9VAC25-870-54.C)(CGP Part II.A.3) Technical Criteria 11.113 ❑ II.0 ❑
12
The SWPPP contains an adequate pollution prevention plan? (9VAC25-
870-54.D)(CGP Part II.A.4)
The SWPPP identifies impaired water(s), approved TMDL, pollutant(s) of
13
concern, exceptional waters and the additional controls measures
applicable? (9VAC 25-870-54.E)(CGP Part IIA.5 (a-b))
14
Delegation of Authority is provided and signed in accordance with Part III
K? (CGP Part 11 A.7)
15
The SWPPP is signed and dated in accordance with Part III K? (CGP Part
11 A.8)
SWPPP AMENDMENTS, MODIFICATIONS AND UPDATES
Compliant?
Reviewed during inspection? No
Comments/Description
Is the SWPPP being amended whenever there is a change in the design,
16
construction, operation, or maintenance that has a significant effect on the
discharge of pollutants to surface waters? (CGP Part 11 B(1))(9VAC25-870-
54.G)
Has the SWPPP been amended if inspections or investigations by the
17
operator's qualified personnel, or by local, state or federal officials find that
existing control measures are ineffective in minimizing pollutants in
discharges? (CGP Part II B(2))(9VAC25-870-54.G)
18
Contractor(s) that will implement and maintain each control measure are
identified? (CGP Part 11 B(3))(9VAC25-870-54.G)
Have there been updates to the SWPPP when any modifications to its
implementation have occurred, including a record of dates when major
19
grading activities occur, construction activities temporarily or permanently
cease on a portion of the site or stabilization measures are initiated? (CGP
Part 11 B.4(a))(9VAC25-870-54.G)
20
Is there documentation in the SWPPP of replaced or modified controls?
(CGP Part 11 B.4(b))(9VAC25-870-54.G)
21
Is the SWPPP updated to indicate areas that have reached final
stabilization? (CGP Part 11 B.4(c))(9VAC25-870-54.G)
Is the SWPPP updated to indicate properties that are no longer under the
22
legal control of the operator and the dates on which the operator no longer
had legal control over each property? (CGP Part II B.4(d))(9VAC25-870-
54.G)
Does the SWPPP identify the date of any prohibited discharges, the
23
volume released, actions taken to minimize the impact of the release and
measures taken to prevent the recurrence of any prohibited discharge?
(CGP Part 11 B.4(e-f)) (9VAC25-870-54.G)
24
mendments, modifications, or updates to the SWPPP are signed in
accordance with Part III K? (CGP Part II B(5))(9VAC25-870-54.G)
INSPECTIONS AND CORRECTIVE ACTIONS
Compliant?
Reviewed during inspection? No
Comments/Description
Inspections required by the SWPPP are conducted at the required
25
frequency, including a modified frequency for impaired water(s), approved
TMDL(s), and exceptional waters when applicable? (CGP Part II F (2))
(CGP Part II A.5.b.3)
26
Inspection reports are completed and signed in accordance with CGP
Part 11 F (3-4)? (CGP Part 11 F (3-4))
Page 2 of 5
27
Corrective actions are taken consistent with the requirements of the
CGP? (CGP Part II G(1-2))
ESC AND SWM PLAN IMPLEMENTATION
Compliant?
Reviewed during inspection? Yes
Comments/Description
28
Have stream buffers and steep slopes been protected as shown on the
yes
plan?
Sequencing of the project is implemented in accordance with the
yes
29
approved erosion and sediment control plan and stormwater management
plans? (9VAC25-870-54.B and C)
Have all denuded areas requiring temporary or permanent stabilization
Project has been dormant for longer than 14 days.
been stabilized, and have stabilization requirements for impaired waters,
Temporary stabilizing is needed
30
approved TMDL(s), pollutants of concern and exceptional waters, when
No
applicable, been met? (9VAC 25-840-40.1) (9VAC25-870-54.B) (9VAC25-
880-60) (CGP Part I F.1(a)) (CGP Part II A.5.b(1)) (CGP Part II A.2.c (8))
(CGP II E(1-2))
Are soil stockpiles adequately stabilized with seeding and/or protected
N/A
31
with sediment trapping measures? (9VAC 25-840-40.2) (CGP Part II
A.2(c)) (9VAC25-870-54.B)
A permanent vegetative cover has been established that is uniform,
N/A
32
mature enough to survive and will inhibit erosion? (9VAC 25-840-40.3)
(CGP Part II A.2(c)) (CGP II E(1-2)) (9VAC25-870-54.B)
Have sediment trapping facilities been constructed as the first step in land
N/A
33
disturbance activities? (9VAC 25-840-40.4) (CGP Part 11 A.2(c)) (CGP II
E(1-2)) (9VAC25-870-54.B)
Have earthen structures been stabilized immediately after installation?
N/A
34
(9VAC 25-840-40.5) (CGP Part II A.2(c)) (CGP II E(1-2)) (9VAC25-870-
54.13)
Are sediment traps and basins installed in accordance with MS-6 and the
N/A
35
approved plan? (9VAC 25-840-40.6) (CGP Part II A.2.c (9)) (CGP Part II
A.2(c)) (CGP II E(1-2)) (9VAC25-870-54.B)
Are finished cut and fill slopes adequately stabilized to prevent or correct
No
See comment and photo item 30
36
excessive erosion? (9VAC 25-840-40.7) (CGP Part II A.2(c)) (CGP II E(1-
2)) (9VAC25-870-54.B)
Is concentrated runoff down cut or fill slopes contained in an adequate
Silt fence observed at time of visit to be under
37
permanent or temporary structure? (9VAC 25-840-40.8) (CGP Part II
No
pressure from sediment buildup and location related
A.2(c)) (CGP II E(1-2)) (9VAC25-870-54.B)
o proximity of the toe of fill.
Is adequate drainage or other protection provided for water seeps?
N/A
38
(9VAC 25-840-40.9) (CGP Part II A.2(c)) (CGP II E(1-2)) (9VAC25-870-
54.13)
Do all operational storm sewer inlets have adequate inlet protection?
No
39
(9VAC 25-840-40.10) (CGP Part II A.2(c)) (CGP II E(1-2)) (9VAC25-870-
54.13)
Are stormwater conveyance channels adequately stabilized with channel
N/A
40
lining and/or outlet protection? (9VAC 25-840-40.11) (CGP Part II A.2(c))
(CGP II E(1-2)) (9VAC25-870-54.B)
Is in -stream construction conducted using measures to minimize channel
N/A
41
damage? (9VAC 25-840-40.12) (CGP Part II A.2(c)) (CGP II E(1-2))
(9VAC25-870-54. B )
Are temporary stream crossings of non -erodible material installed where
N/A
42
applicable? (9VAC 25-840-40.13) (CGP Part II A.2(c)) (CGP II E(1-2))
(9VAC25-870-54. B )
43
Is necessary restabilization of in -stream construction complete? (9VAC
N/A
25-840-40.15) (CGP II E(1-2)) (9VAC25-870-54.B)
Are utility trench operations conducted and stabilized in accordance with
yes
44
MS-16? (9VAC 25-840-40.16) (CGP Part II A.2(c)) (CGP II E(1-2))
(9VAC25-870-54. B )
Are soil and mud kept off paved or public roads to minimize the transport
yes
45
of sediment? (9VAC 25-840-40.17) (CGP Part II A.2(c)) (CGP II E(1-2))
(9VAC25-870-54. B )
Page 3 of 5
Have all temporary control structures that are no longer needed been
46
removed and disturbed soil resulting from their removal permanently
N/A
stabilized? (9VAC 25-840-40.18) (CGP Part II A.2(c)) (CGP II E(1-2))
(9VAC25-870-54. B )
Are properties and waterways downstream from development adequately
Observed failing measures that will allow downstream
47
protected from erosion, sediment and damage in accordance with the
No
damage
standards and criteria specified by 9VAC25-840.19(a-n)? (9VAC 25-840-
40.19(a-n))
48
Permanent control measures included in the SWPPP are in place?
N/A
(9VAC25-870-54.C) (9VAC25-880-60) (CGP Part II F.1(a))
POLLUTION PREVENTION PLAN IMPLEMENTATION
Compliant?
Reviewed during inspection? Yes
Comments/Description
Practices are in place to prevent and respond to leaks, spills, and other
releases including (i) procedures for expeditiously stopping, containing,
yes
49
and cleaning up spills, leaks, and other releases; and (ii) procedures for
reporting leaks, spills, and other releases in accordance with Part III G?
(CGP Part II A.4.e(1))(9VAC25-870-56)
Practices are in place to prevent the discharge of spilled and leaked fuels
No
None observed at time of visit
50
and chemicals from vehicle fueling and maintenance activities? (CGP Part II
A.4.e(2))(9VAC25-870-56)
Practices are in place to prevent the discharge of soaps, solvents,
None observed at the time of inspection
51
detergents, and wash water from construction materials, including the
No
clean-up of stucco, paint, form release oils, and curing compounds? (CGP
Part II A.4.e(3))(9VAC25-870-56)
Practices are in place to minimize the discharge of pollutants from vehicle
No
None observed at time of inspection
52
and equipment washing, wheel wash water, and other types of washing?
(CGP Part II A.4.e(4))(9VAC25-870-56)
53
Concrete wash water is directed into a leak -proof container or leak -proof
No
None observed, clear evidence of concrete wash
directly on the ground.
settling basin? (CGP Part II A.4.e(5))(9VAC25-870-56)
Practices are in place to minimize the discharge of pollutants from
No
Observed trash outside of a proper receptacle
54
storage, handling, and disposal of construction products, materials, and
wastes? (CGP Part II A.4.e(6))(9VAC25-870-56)
Practices are in place to prevent the discharge of fuels, oils, and other
No
See item 54 photo and description
55
petroleum products, hazardous or toxic wastes, and sanitary wastes?
(CGP Part II A.4.e(7)(9VAC25-870-56)
Practices are in place to minimize any other discharge from the potential
N/A
56
pollutant -generating activities not addressed above, when applicable?
(CGP Part II A.4.e(8))(9VAC25-870-56)
Page 4 of 5
Page 5 of 5
Construction General Permit Site Inspection Report
Request for Correction Action
Check
Regulatory
Occur.
Observation
Recommended Corrective
List #
Citation/Legal
Action
Requirement*
30
(9VAC 25-840-40.1)
Project has been dormant for
Seed and straw mulch as
(9VAC25-870-54.B)
longer than 14 days.
required by the approved
(9VAC25-880-60) (CGP
Temporary stabilizing is
plan and VESCH manual
Part I F.1(a)) (CGP Part
needed
11 A.5.b(1)) (CGP Part II
A.2.c (8)) (CGP 11 E(1-2))
36
(9VAC 25-840-40.7)
See comment and photo item
Seed and straw mulch as
(CGP Part 11 A.2(c))
30
required to reduce erosion of
(CGP 11 E(1-2))
the slope.
(9VAC25-870-54. B)
37
(9VAC 25-840-40.8)
Silt fence observed at time of
Remove all buildup from the
(CGP Part 11 A.2(c))
visit to be under pressure
silt fence, maintain as
(CGP 11 E(1-2))
from sediment buildup and
required, and remove silt
(9VAC25-870-54.B)
location related to proximity of
fence from toe. Silt fence is to
the toe of fill.
have a minimum of 6 foot free
space between it and the
area of disturbance.
47
(9VAC 25-840-40.19(a-
Observed failing measures
Make corrections necessary
n))
that will allow downstream
to protect downstream
damage
properties
50
(CGP Part 11 A.4.e(2))
None observed at time of visit
Ensure there is a practice in
(9VAC25-870-56)
place.
51
(CGP Part 11 A.4.e(3))
None observed at the time of
If there will be a fuel tank
(9VAC25-870-56)
inspection
onsite or any storage of
petroleum, it must be within a
lined containment area.
52
(CGP Part 11 A.4.e(4))
None observed at time of
No wash rack or water
(9VAC25-870-56)
inspection
observed. Install a
containment for wash water
and ensure there is a rack
and high pressure wash
available
53
(CGP Part 11 A.4.e(5))
None observed, clear
Install proper concrete
(9VAC25-870-56)
evidence of concrete wash
washout.
directly on the ground.
54
(CGP Part 11 A.4.e(6))
Observed trash outside of a
Cleanup all trash and contain
(9VAC25-870-56)
proper receptacle
to a protected receptacle
55
(CGP Part 11 A.4.e(7)
See item 54 photo and
Fuels and petroleum waste
(9VAC25-870-56)
description
must be within a lined
containment area for proper
disposal, as per manufacturer
specifications.
Recommended 9/3/2020
Corrective Action
Deadline:
Targeted Re- 9/7/2020
Inspection Date:
Comments:
*Refers to applicable regulation found in the most recent publication of the State Water Control Law (Va. Code § 62.1-44.2 et seq.), Virginia Erosion and
Sediment Control Regulations (9VAC25-840), the Virginia Stormwater Management Program (VSMP) Regulations(9VAC25-870), or the General Permit for
Discharges of Stomroneterfrom Construction Acti Aties (9VAC25-880).
Construction General Permit Site Inspection Photo Log
Photos for Item 2
Photos for Item 4
Fhoto Description:
Photos for Item 10
Photo Description:
Photos for Item 30
Image_637339741044879990.jpg 1.88MB
Photo Description: Shot of current conditions, slope is eroding without temporary seed
Photos for Item 37
20200825_133010(0).jpg.jpg 612.95KB
Photo Description: Example of the silt fence with build up and pressure from material tight to it.
Photos for Item 39
20200825_133059.jpg.jpg 356.64KB
Photo Description: Example of partially protected Filtera.
Photos for Item 53
20200825_133128.jpg.jpg 761.23KB
¢� R
Asa ,
Photo Description: Example of concrete not contained as per SWPPP requirements.
Photos for Item 54
20200825_133258.jpg.jpg
Ow
w7w--� �M- �M�
Photo Description
341.14KB
Photo shows example of trash not contained in a proper receptacle. Also shows a
bottle that appears to have some type of chemical or petroleum product in it and
not contained.
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road
Charlottesville, Virginia 22902
434 296-5832
Inspection Date: 8/25/2020
County Inspector