Loading...
HomeMy WebLinkAboutSDP202000002 Review Comments Minor Amendment 2020-08-25pF AL@F, C u �'� in County of Albemarle Department of Community Development To: Craig Kotarski, Timmons Group From: Tori Kanellopoulos — Senior Planner Division: Planning Services Date: August 25, 2020 REV 3 Subject: SDP202000002 —Keswick Hall Spa —Minor Amendment The Planner for the Planning Services Division of the Albemarle County Department Community Development will approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Planning (Tori Kanellopoulos) i Sheet C2.0, the slopes are listed as `managed', but u�UII,y ,� ,mcal'. a.List as critical and include reference on SDP to critical slopes waiver that was approved by the Board of Supervisors. b. REV 2: Addressed. 2. [18-32.5.2 and 18-32.6.2] Ownership information: Some demolition and improvements appear to be shown on the adjacent parcel (TMP 80-90), such as removing and replacing the gate. Other parcel/ownership information should be included. a. REV 2: Addressed. 3. [18-32.7.2.3] Safe pedestrian movement: The crosswalk, as shown on SDP2018-79, has been removed across Club Drive. The crosswalk should be provided for safe pedestrian access across the area. a. REV 2: Addressed. 4. [18-32.7.2.3] Safe pedestrian movement: A crosswalk should also be provided across the entrance to the Spa area: a. REV 2: Addressed. 5. [18-4.16.12] Parking dimensions: Clarify the area of paver parking that is unstriped. Is ng space" +ure pote parking? 2: Ads 6. [18-32.7.4.2 and 18-32.7.5.31 Easement Plats: An easement plat is required for the proposed SWM facilities management easement. An easement plat was previously approved for this easement, however the dimensions and design have changed. o1 IUMI d6 Ud51 ICU d11U Id UCIUU III ICS, IUI d6 d IId IU ICU dlCd, d6 11116 WUUIU UU difficult to read. b. REV 2: An easement plat is required. Ensure final version of this site plan and easement plat match. c. REV 3: The 20' public drainage easement (as shown on the recorded plat) appears to be labeled as a SWM easement on the site plan. d. REV 3: The full revised SWM boundaries need to be more clearly labeled/shown on the site plan. 7. [18-a oposed utilities on the landscaping plan. I' is not r. with landscaping and utilities. a. REV 2: Proposed tree near end of parking area appears to be conflicting with proposed waterline: b. REV 3: Addressed. 8. [18-32.5.2 and 18-32.6.2] Utilities: Clarify the reference on Sheet C4.0 to "see standard ACSA sewer service lateral connection detail". as this site is not in the ACSA jurisdictional area. a. REV 2: Addressed. 9. [18-4.17] Outdoor lighting: No changes to the lighting plan were shown or included as part of this minor amendment submittal. However, looking at the approved lighting plan per SDP2018-79, it appears that the new site design with this minor amendment would necessitate changes to the lighting plan. For example, the parking areas have changed, and the fountain/walking area in the garden is no longer provided. Provide an updated lighting plan and cloud all changes. a. REV 2: Include the required note (typed out) on the lighting plan: "Each outdoor luminaire emitting 3,000 or more lumens shall be a full cutoff fixture." b. REV 2: The Light Loss Factor must be 1.00. c. REV 2: Clarify "NIA" for lamp lumens for L1, DF-M, and L2. Is N/A listed as these lights are less than 3,000 lumens? d. REV 2: Move the light cutsheet to be with the rest of the lighting plan. e. REV 3: All lighting plan comments have been addressed. 10. [18-32.7.9] Landscaping plan comments: a. Sheet L3.3 from SDP2018-79: Include an updated landscape mitigation plan. Given that the design and orientation of the building and parking has changed, it appears there would be some changes to this sheet as well. i. REV 2: Addressed. b. [18-32.7.9.7] Screening: The reference to `vegetated screen' in SDP2018-79 was removed with this submittal. Screening vegetation should be provided, to screen the parking lot from adjacent residential uses and RA districts. i. REV 2: Addressed. c. [18-32.7.9.4] Landscaping plan requirements: Revise counts and labeling for t following: Fagus Grandiflora, Thuja Occidentalis, and Juniperis Virginiana. i. REV 2: Addressed. Engineering (John Anderson) 1. REV 3: Easement plat recorded Aug 14, 2020. Please provide deed bk.-pg. reference to recorded easements on C6.6. Drainage deed recorded at bk.-pg. 5368/613; SWM facility deed + plat at bk.-pg. 5368/603. [review item 4] 2. REV 2: See attached comment letter, dated May 7, 2020. 3. See attached comment letter dated February 11, 2020. VDOT (Adam Moore) 1. No objection. See attached letter dated February 20, 2020. Fire/Rescue (Shawn Maddox) 1. REV 3: Fire Rescue received the fire flow calculations via email on 5/26/2020 and updated the status to no objections, thank you. 2. REV 2: Please provide the needed fire flow for the structure. This can be done via email and then fire rescue can change review comments to no objections. Health Department (Alan Mazurowski) 1. No objection. See attached correspondence dated February 19, 2020. Inspections (Michael Dellinger) 1. REV 2: No Objection. Architectural Review Board (Margaret Maliszewski) 1. No Objection. Please contact Tori Kanellopoulos in the Planning Division at vkanellopoulosCa.albemarle.oro or 434-296-5832 ext. 3270 for further information.