Loading...
HomeMy WebLinkAboutSDP201900072 Plan - Revision Final Site Plan and Comps. 2020-08-26JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C0.0 - C0VER.dwg | Plotted on 8/26/2020 10:30 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSCOUNTY OF ALBEMARLE, VIRGINIA BEAVER CREEK - MEDICAL OFFICE BUILDING VICINITY MAP 1"=1000' DEVELOPER: TURNER ENTERPRISES 250 WEST MAIN STREET, SUITE 201 CHARLOTTESVILLE, VA 22902 CONTACT: JOHN THIER TELEPHONE: (434) 533-0788 ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVENUE, SUITE 200 CHARLOTTESVILLE, VA 22903 CONTACT: CRAIG KOTARSKI, P.E. TELEPHONE: (434) 327-1688 11/25/2019 SITE LOCATION WATER FLOW (AVERAGE DAILY DEMAND) AVERAGE FLOW RATES (FROM TABLE A 12VAC5-590-690, VDH WATERWORKS REGULATIONS): OFFICE: 250 GPD/1,000 SF = 26,600 X 250 GPD/1,000 SF = 6,650 GPD AVERAGE HOUR: 6,650 / 24 = 277 GALLONS PER HOUR MAX HOUR = 300% OF AVERAGE HOUR = 277 X 3 = 831 GALLONS PEAK DOMESTIC DEMAND = MAX HOUR X 2 = 831 X 2 = 1,662 GALLONS SEWER FLOW (AVERAGE DAILY FLOW) OFFICE: 26,600 SF X (250 GPD PER 1,000 SF) = 6,650 GPD UTILITY DEMANDS SIGNATURE PANEL: APPROVAL DATE DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNING & ZONING ENGINEERING INSPECTIONS ARCHITECTURAL REVIEW BOARD DEPARTMENT OF FIRE AND RESCUE ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIA DEPARTMENT OF TRANSPORTATION ALBEMARLE COUNTY ARCHITECTURAL REVIEW BOARD COVER SHEETC0.0 N/A Sheet List Table Sheet Number Sheet Title C0.0 COVER SHEET C1.0 NOTES AND DETAILS 1 C1.1 NOTES AND DETAILS 2 C1.2 NOTES AND DETAILS 3 C1.3 NOTES AND DETAILS 4 C2.0 EXISTING CONDITIONS C2.1 DEMOLITION PLAN C3.0 EROSION & SEDIMENT CONTROL NOTES C3.1 EROSION & SEDIMENT CONTROL DETAILS C3.2 EROSION & SEDIMENT CONTROL PHASE I C3.3 EROSION & SEDIMENT CONTROL PHASE II C4.0 SITE AND UTILITIES PLAN C5.0 GRADING AND DRAINAGE PLAN C5.1 GRADING SPOT SHOT PLAN C5.2 SIGHT DISTANCE PROFILES C6.0 STORMWATER MANAGEMENT PLAN C6.1 STORMWATER SUMMARY PLAN C6.2 STORMWATER CALCULATIONS C6.3 STORMWATER DETENTION DETAILS C7.0 STORM AND UTILITY PROFILES C8.0 EASEMENT PLAN L1.0 LANDSCAPE PLAN L2.0 LANDSCAPE NOTES AND DETAILS L3.0 ARCHITECTURAL ELEVATIONS TOTAL = 19 SHEETS NOTES TAX MAP PARCEL AND OWNER INFO:PARCEL 06000-00-00-03800 2246-2248 IVY ROAD LLC 2246-2248 IVY ROAD CHARLOTTESVILLE, VA 22903 ZONING: HC - HIGHWAY COMMERCIAL ENTRANCE CORRIDOR OVERLAY AIRPORT IMPACT AREA OVERLAY MAGISTERIAL DISTRICT: JACK JOUETT SOURCE OF SURVEY, BOUNDARY, AND TOPOGRAPHY:TIMMONS GROUP 28 IMPERIAL DRIVE STAUNTON, VA 24401 (504) 885-0920 CONTACT: MICHAEL W. DORSEY CONDUCTED: 7/18/2019 DATUM:VERTICAL:NAVD88 HORIZONTAL: NAD83 (NA2011), VIRGINIA STATE GRID, SOUTH ZONE WATERSHED:MOORES CREEK - NOT A WATER SUPPLY WATERSHED SETBACKS: FRONT (BUILDING): 10 FT (MINIMUM) FROM ROW OR EXTERIOR EDGE OF SIDEWALK IF THE SIDEWALK IS OUTSIDE OF THE ROW; 30 FT (MAXIMUM) FRONT (PARKING):10 FT FROM PUBLIC STREET ROW SIDE: ADJ. TO RESIDENTIAL: 50 FT (STRUCTURE), 20 FT (OFF-STREET PARKING OR LOADING SPACE) ADJ. TO COMMERCIAL: IN ACCORDANCE WITH BUILDING CODE REAR:ADJ. TO RESIDENTIAL: 50 FT (STRUCTURE), 5 FT (OFF-STREET PARKING OR LOADING SPACE)* ADJ. TO COMMERCIAL: IN ACCORDANCE WITH BUILDING CODE *SPECIAL EXCEPTIONS TO THE REAR PARKING SETBACK, PURSUANT TO 4.20(a), AND THE USE BUFFER, PURSUANT TO 21.7(c), FOR THIS DEVELOPMENT WERE APPROVED BY THE BOARD OF SUPERVISORS ON APRIL 15, 2020 WITH THE FOLLOWING CONDITIONS: 1. THE BUFFER DISTURBANCE WITHIN 20 FEET, AS MEASURED FROM THE REAR PROPERTY LINE, IS ALLOWED ONLY FOR SCREENING, LANDSCAPING, AND PARKING. NO DUMPSTER OR DUMPSTER PAD MAY BE LOCATED CLOSER THAN 20 FEET FROM THE REAR PROPERTY LINE. 2. ALL SCREENING, PARKING LOT LANDSCAPING, AND LANDSCAPING ISLANDS SHALL MEET ARCHITECTURAL REVIEW BOARD REQUIREMENTS. 3. SURFACE PARKING SHALL BE NO CLOSER THAN 5 FEET FROM THE REAR PROPERTY LINE, AS SHOWN ON THE EXHIBIT TITLED "BEAVER CREEK - MEDICAL OFFICE BUILDING - SPECIAL EXCEPTION: SITE LAYOUT WITH SPECIAL EXCEPTION REQUEST" AND DATED DECEMBER 19, 2019. STEPBACKS:15 FT FOR EACH STORY THAT BEGINS ABOVE 40 FT IN HEIGHT OR FOR EACH STORY ABOVE THE THIRD STORY, WHICHEVER IS LESS PRESENT USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) PROPOSED USE: ±26,600 SF MEDICAL OFFICE SPACE REQUIRED PARKING PER ORDINANCE: MEDICAL OFFICE: (26,600 SF x 0.8) X (1 SPACE / 200 SF) = 107 SPACES PROPOSED PARKING: 107 SPACES ADA PARKING REQUIRED: 5 SPACES (AT LEAST 1 VAN ACCESSIBLE SPACES) (PER 2012 VCC) ADA PARKING PROVIDED: 5 SPACES MAXIMUM BUILDING HEIGHT:65 FEET PROPOSED DISTURBED AREA:1.51 ACRES EXISTING IMPERVIOUS AREA:1.03 ACRES PROPOSED IMPERVIOUS AREA:1.24 ACRES AREA OF PAVED PARKING/CIRCULATION:0.93 ACRES PROPOSED OPEN SPACE:0 ACRES PROPOSED RECREATION AREA:0 ACRES LAND USE: MEDICAL OFFICE BUILDING ITE CODE: 720 AMOUNT: 26,600 UNITS: SF (GFA) TRIP GENERATION WEEKDAY ADT AM PEAK HOUR PM PEAK HOUR 926 IN OUT TOTAL IN OUT TOTAL 58 36 94 43 66 109 SE1.0 CALCULATED LIGHTING LEVEL PLAN SE5.0 FIXTURE DETAILS SE5.1 FIXTURE DETAILS FINAL SITE PLAN (SDP201900072) REF: INITIAL SITE PLAN SDP201900051 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C1.0 - NOTES AND DETAILS.dwg | Plotted on 8/26/2020 10:31 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSNOTES AND DETAILS 1C1.0 N/A + 240.5 200 200 ROADS LEGEND STORM PIPE & STRUCTURE NO. DROP INLET & STRUCTURE NO. CURB CURB & GUTTER DRY CURB & GUTTER PROPOSED PAVEMENT PAVED DITCH JUTE MESH DITCH CENTERLINE OF DITCH BENCH MARK CLEARING LIMITS VDOT STANDARD STOP SIGN EXISTING CONTOUR PROPOSED CONTOUR EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION EXISTING SANITARY SEWER SEWERTRAFFIC STOP BAR EXISTING WATER LINE PROPOSED WATER LINE PROPOSED VALVE PROPOSED TAPPING SLEEVE PROPOSED FIRE HYDRANT (COMPLETE) WATER GRADING R-1 100 100 TC 240.5 PARKING COUNT1 GENERAL NOTES 1.CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR AS BUILT DOCUMENTATION, AS REQUIRED BY THE LOCALITY. THIS INCLUDES, BUT IS NOT LIMITED TO, TESTING, INSTALLATION DOCUMENTATION, SURVEY, ETC. ALL REQUIREMENTS SHALL BE DISCUSSED WITH THE LOCALITY PRIOR TO BEGINNING CONSTRUCTION. 2.ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 3.PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS. 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT STANDARDS. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE-CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY . 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER'S REPRESENTATIVE FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 19. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 20. THE OWNER'S REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 22. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND BRIDGE STANDARDS. 24. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF WAY. (N/A) 25. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE OF ROAD. (N/A) 26. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG-7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. (N/A) 28.CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL FOR REVIEW BY THE ENGINEER, OWNER'S REPRESENTATIVE, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 29.ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON-SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2015 UNIFORM STATEWIDE BUILDING CODE, 2015 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI A117.1-03. 30.THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 31.HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. 32.ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 6" SHALL HAVE A 6:1 STONE WEDGE PLACED AT THE END OF THE DAY 33.VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 34.ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 35.ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. 36.SEPARATE DEMOLITION PERMIT REQUIRED FOR EXISTING BUILDING REMOVAL ALONG WITH UTILITY RELEASES. 37.BUILDING OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST HAVE AN ASBESTOS SURVEY PERFORMED IN ORDER TO APPLY FOR A PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF POSITIVE FOR SUCH. CONTACT VDOLI FOR ADDITIONAL REQUIREMENTS AND PERMITS FOR DEMOLITION PROJECTS. 38.RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN ALSO. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1.PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2.ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. 3.EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND MUST BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4.ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5.THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6.PAVED, RIP-RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7.ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8.UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 9.ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). BLASTING NOTES 1.BLASTING SHALL NOT BE PERMITTED ON THIS PROJECT. ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES 1.ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2.PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3.FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. GENERAL CONSTRUCTION NOTES FOR EROSION AND SEDIMENT CONTROL 1.THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE-CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. 2.ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. 3.ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 4.A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5.PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF-SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. 6.THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN APPROVING AUTHORITY. 7.ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8.DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. 9.THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF-PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 10.ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. 11.ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. 12.BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING ORDINANCE SECTION 5.1.28. 13.ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF ALBEMARLE. 14.BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL-TYPE POWER EQUIPMENT SHALL BE LIMITED TO THE HOURS OF 7:00AM TO 9:00PM. 15.BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF SLIDES, SINKING, OR COLLAPSE. 16.THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER PORTION OF THE PROPERTY. 17.TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 18.PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND MULCH. AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 1000LBS/ACRE AND CONSIST OF A 10-20-10 NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 19.MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT. ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY. SILT TRAPS SHALL BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. ALL SEEDED AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE CLEANED AND REPAIRED IMMEDIATELY. 20.ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS OF FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 21.THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF APPROVAL. (WATER PROTECTION ORDINANCE SECTION 17-204G.) 22.PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS WITHIN NINE (9) MONTHS AFTER THE DATE THE LAND DISTURBING ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE SECTION 17-207B) ACSA GENERAL WATER & SEWER CONDITIONS 1.WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2.THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 3.ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 4.DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 6.ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 7.ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 8.VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. 9.TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. 10.THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO-LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). + 240.5 200 200 ROADS LEGEND STORM PIPE & STRUCTURE NO. DROP INLET & STRUCTURE NO. CURB CURB & GUTTER DRY CURB & GUTTER PROPOSED PAVEMENT PAVED DITCH JUTE MESH DITCH CENTERLINE OF DITCH BENCH MARK CLEARING LIMITS VDOT STANDARD STOP SIGN EXISTING CONTOUR PROPOSED CONTOUR EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION EXISTING SANITARY SEWER SEWERTRAFFIC STOP BAR EXISTING WATER LINE PROPOSED WATER LINE PROPOSED VALVE PROPOSED TAPPING SLEEVE PROPOSED FIRE HYDRANT (COMPLETE) WATER TC = TOP OF CURB BC = BACK OF CURB EP = EDGE OF PAVEMENT TW = TOP OF WALL BW = BOTTOM OF WALL TS = TOP OF STAIRS BS = BOTTOM OF STAIRS N/A = NOT APPLICABLE TO THIS PROJECT GRADING R-1 100 100 TC 240.5 PARKING COUNT1 DETENTION PIPE MAINTENANCE JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C1.0 - NOTES AND DETAILS.dwg | Plotted on 8/26/2020 10:31 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSNOTES AND DETAILS 2C1.1 N/A DENOTES LIGHT DUTY ASPHALT PAVEMENT ON PLANS No Scale LIGHT DUTY ASPHALT PAVEMENT SECTION 8" TYPE 21B AGGREGATE BASE COURSE 2.0" BITUMINOUS CONCRETE SURFACE COURSE - SM-9.5A COMPACTED SUBGRADE DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PLANS No Scale HEAVY DUTY ASPHALT PAVEMENT SECTION 2.0" INTERMEDIATE BASE COURSE - BM25.0 8" TYPE 21-B AGGREGATE SUBBASE COURSE 2.0" ASPHALTIC CONCRETE SURFACE COMPACTED SUBGRADE COURSE - SM-9.5A NOTE:SIDEWALKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH VDOT STANDARDS. DENOTES CONCRETE SIDEWALK PAVEMENT ON PLANS NON-SLIP BROOM FINISH VARIABLE WIDTH' MAX. CROSS SLOPE 2% COMPACTED SUBGRADE 4" 3,000 PSI AIR-ENTRAINED CONCRETE 4" TYPE 21B STONE COVER No Scale CONCRETE SIDEWALK PAVEMENT SECTION No Scale HEAVY DUTY CONCRETE SECTION DENOTES CONCRETE SERVICE AREA PAVEMENT ON PLANS 6" TYPE 21A STONE COVER 10" 3,000 PSI AIR ENTRAINED PORTLAND CEMENT CONCRETE COMPACTED SUBGRADE (CBR 11.2) WWF 6x6 W2.9xW2.9 NON-SLIP BROOM FINISH 2" EXPANSION JOINT WITH PREMOLDED EXPANSION FILLER, "ZIP STRIP" OR EQUIV., SEAL WITH SILICONE SEALANT 1/4" SEALANT SPECIFIED ON PLANS SLOPE UNLESS OTHERWISE MATCH EX. CROSS SAWCUT EX. EDGE OF PAVEMENT COURSE SURFACE PROPOSED SURFACE COURSE PAVEMENT EXISTING PAVEMENT & REMOVE COURSE EX. SURFACE SAWCUT THROUGH IN WITH EXISTING PAVEMENT NOTE: PROPOSED PAVEMENT MUST TIE EX. E/PEXISTING PAVEMENT PROPOSED PAVEMENT AGGR. BASE BASE COURSE 2" + 2' MIN. MILL EX.EX. C/L PVMT.4" 21-B STONECOMPACTED SUBGRADE CONC. WALK EXPANSION JOINT AT MAX OF 30', WITH PREMOLDED EXPANSION FILLER CONTROL JOINT SPACED AT WIDTH OF WALK 14" 1" R= 14" No Scale CONCRETE SIDEWALK JOINT DETAIL No Scale PAVEMENT REPLACEMENT JOINT DETAIL REGULAR SPACEHANDICAP SPACES 2% MAX. CONCRETE BUMPER BLOCK ANCHOR WITH 5/8" REBAR IMBEDDED 24" IN GROUND HANDICAP SIGN LOCATION (VAN)HANDICAP SIGN LOCATION (TYP.) EOP EDGE OF PAVEMENTPAINTED PER VDOT SPEC. 18'18' 9'5'11'8'5'8' 4" PAINTED STRIPE (TYPICAL) 4" VAN ACCESSIBLE TYPICAL ACCESSIBLE No Scale TYPICAL PARKING SPACE DETAILS No Scale PARKING SIGNS FOR THE DISABLED SPACES SHALL BE IDENTIFIED BY ABOVE GRADE SIGNS AS RESERVED FOR PHYSICALLY DISABLED PERSONS. PROVIDE ONE (1) R-7-8 SIGN AT EACH PARKING SPACE INDICATED ON SITE PLAN. SIGN SHALL BE ALUMINUM (PAINTED WHITE) WITH GREEN LETTERS AND INTERNATIONAL WHEELCHAIR SYMBOL. SIGN SHALL BE PLACED ON STEEL POST 1-1/2" O PAINTED BLACK SET IN MIN. 2' OF CONCRETE. VA. SIGN FOR THE DISABLED ON 0.80 GAUGE ALUMINUM. COLORS: GREEN BORDER & LEGEND, BLUE SYMBOL FOR ACCESSIBILITY, WHITE BACKGROUND. 6' ABOVE FINISHED GRADE 6' ABOVE FINISHED GRADE STD. U POST GALVANIZED SIGN POST TO BE DRIVEN No Scale SIGN AND POST DETAIL 6' 2' ANCHOR WITH 5 8" REBAR IMBEDDED 24" IN GROUND; 2 PER WHEEL STOP 7-1/2" 5" 6' LENGTH 0.5' FROM EP 6" 5' EP No Scale CURB TRANSITION DETAIL No Scale PRECAST CONCRETE WHEEL STOP No Scale BOLLARD DETAIL 6" DIA. STEEL PIPE FILLED WITH CONCRETE AND POWDER COATED (COLOR TO BE SELECTED BY OWNER) 3,000 PSI AIR-ENTRAINED 2'-0" DIAMETER PAVEMENT PATCH 3.5' 3.5' STEEL CAP CONC. FOOTING BELOW STEEL PIPE 2" MINIMUM CONCRETE No Scale MUTCD R7-6 SIGN DETAIL 6"x6" POST 2"x6" RAIL CONCRETE FOOTING 3,000 PSI @ 28 DAYS8'4" VDOT #57 STONE 1"x6" FENCE BOARD FINISH GRADE 6' 1"x6" FENCE BOARD - DOG EARED 6"x6" POST @ 6' O. / C. ± NOTES: - ALL LUMBER TO BE PRESSURE TREATED, SOUTHERN YELLOW PINE. - ALL FASTENERS TO BE GALVANIZED. 18" DIA.2'-6"2"x6" RAIL 0'-1 1/2"JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C1.0 - NOTES AND DETAILS.dwg | Plotted on 8/26/2020 10:31 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSNOTES AND DETAILS 3C1.2 N/A D No Scale DUMPSTER PAD & ENCLOSURE DETAIL D D OPAQUE SCREENING FENCE DETAIL No Scale 3" CONCRETE COLLAR CRUSHED STONE BEDDING (NEENAH R-1975 OR EQUIVALENT) METAL INSPECTION FRAME W/ SOLID LID 6" DI CLEANOUT OF LINE PLUG AT END EXIST GRADE CLEANOUT DETAIL No Scale COLOR: BEACH DUNE JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C1.0 - NOTES AND DETAILS.dwg | Plotted on 8/26/2020 10:31 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSNOTES AND DETAILS 4C1.3 N/A 18" TREE RD RD RD RD RD RD RD RD RD SIGN HAIR SIGN HC SIGN HC SIGN ANGELA SIGN CO LP WATER TANK LP SIGN SIGN RD RD LP X X OHU 20" WALNUT SIGN SIG N WATER METER VAULT GUY GUY SIGN CO SEPTIC TANK OHUOHUOHU SAN SAN G G GGGGGGGG W W W W W W W W OHU OHU OHU SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHPMHS TOP=583.74 INV.4"IN=574.95 (NW) INV.8"INPVC=574.74 INV.OUT8"PVC=574.89 MHS TOP=580.64 INV.4"IN= 578.24 INV.IN 2-2"PVC=577.79 INV.8"INPVC= 575.84 INV.OUT=575.76 MHS TOP=579.44 INV.8"IN PVC=573.40 INV.OUT8"IN PVC=566.66 MHS TOP=566.26 INV.8"IN=559.81(W) INV.8"IN=560.30(S) INV.OUT=559.96(E) 8" PV C 8" PVC8" P V C MHS TOP=568.87 INV.4"IN=565.62 (W) INV.4"IN=562.70 (W) INV.3"IN=564.45 (SW) INV.6"IN=566.02 (S) INV.OUT8"IN=562.65 (E) SIGN SIGN SIGN SIGN LANDSCAPE PAVEMENT PAVEMENTPAVEMENT PAV E M E N T POLE PPF1 POLE PPF2326 POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1POLE PPF1OHUPOLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 SD INLET TOP=576.08 INV.IN 6"PVC=574.83 INV.OUT 12"RCP=574.44 SD INLET TOP=583.30 INV.OUT 6"RCP=581.50 6" PVC 12" RCPPOLE PP POLE PP 12" STONE WALL BUILDING 1-1/2 STORY STONE AND FRAMEAC UNITS WOODEN FENCE 20' SANITARY SEWER EASEMENT DB 488 PG 624 CURB CURB CURBCURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP 574.76 PPF1 SAN SAN UG T UG T BUILDING 2 STORY BLOCK AND STUCCO 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN APPROXIMATE LOCATION OF SANITARY PIPE, STORM PIPE/STRUCTURE, CURB, AND SIDEWALK TO BE CONSTRUCTED BY COUNTY AS IVY ROAD SIDEWALK PROJECT. COORDINATION WILL BE REQUIRED. 8''W 8''W 8''W 8''W 8''W 8''W 8''W EXISTING WATER LINE (TO BE RELOCATED DURING IVY ROAD SIDEWALK IMPROVEMENTS) 8" WATER LINE TO BE CONSTRUCTED BY THE COUNTY AS PART OF THE IVY ROAD SIDEWALK PROJECT. IPF IPF BENT ROD /F ROD /F S71 ° 1 1 ' 0 4 " E 246. 5 0 'S24°20'26"W156.05'N79°15' 0 4 " W 15.00'S2°18'34"E106.55'N85°16'44"W 217.00'N10°37'39"E312.85'TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK APPROXIMATE LOCATION OF RELOCATED POLE DUE TO IVY ROAD SIDEWALK PROJECT. LANDSCAPE SHRUB (TYP.) SHRUB (TYP.)5805855775785795815 8 2 583584580 576 577 578 579 581 5 7 0 5 7 5 580 5 6 6 5 6 7 5 6 8 5 6 9 5 7 1 5 7 2 573 5 7 4 57657757 8 579 581 582 583 584 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C2.0 - EXISTING CONDITIONS.dwg | Plotted on 8/26/2020 10:31 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSEXISTING CONDITIONSC2.0 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 18" TREE RD RD RD RD RD RD RD RD RD SIGN HAIR SIGN HC SIGN HC SIGN ANGELA SIGN CO LP WATER TANK LP SIGN SIGN RD RD LP X X OHU 20" WALNUT SIGN SIG N WATER METER VAULT GUY GUY SIGN CO SEPTIC TANK OHUOHUOHU SAN SAN G G GGGGGGGG W W W W W W W W OHU OHU OHU SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHPMHS TOP=583.74 INV.4"IN=574.95 (NW) INV.8"INPVC=574.74 INV.OUT8"PVC=574.89 MHS TOP=580.64 INV.4"IN= 578.24 INV.IN 2-2"PVC=577.79 INV.8"INPVC= 575.84 INV.OUT=575.76 MHS TOP=579.44 INV.8"IN PVC=573.40 INV.OUT8"IN PVC=566.66 MHS TOP=566.26 INV.8"IN=559.81(W) INV.8"IN=560.30(S) INV.OUT=559.96(E) 8" PV C 8" PVC8" P V C MHS TOP=568.87 INV.4"IN=565.62 (W) INV.4"IN=562.70 (W) INV.3"IN=564.45 (SW) INV.6"IN=566.02 (S) INV.OUT8"IN=562.65 (E) SIGN SIGN SIGN SIGN LANDSCAPE PAVEMENT PAVEMENTPAVEMENT PAV E M E N T POLE PPF1 POLE PPF2326 POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1POLE PPF1OHUPOLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 SD INLET TOP=576.08 INV.IN 6"PVC=574.83 INV.OUT 12"RCP=574.44 SD INLET TOP=583.30 INV.OUT 6"RCP=581.50 6" PVC 12" RCPPOLE PP POLE PP 12" STONE WALL BUILDING 1-1/2 STORY STONE AND FRAMEAC UNITS WOODEN FENCE 20' SANITARY SEWER EASEMENT DB 488 PG 624 CURB CURB CURBCURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP 574.76 PPF1 SAN SAN UG T UG T BUILDING 2 STORY BLOCK AND STUCCO 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN APPROXIMATE LOCATION OF SANITARY PIPE, STORM PIPE/STRUCTURE, CURB, AND SIDEWALK TO BE CONSTRUCTED BY COUNTY AS IVY ROAD SIDEWALK PROJECT. COORDINATION WILL BE REQUIRED. 8''W 8''W 8''W 8''W 8''W 8''W 8''W EXISTING WATER LINE (TO BE RELOCATED DURING IVY ROAD SIDEWALK IMPROVEMENTS) 8" WATER LINE TO BE CONSTRUCTED BY THE COUNTY AS PART OF THE IVY ROAD SIDEWALK PROJECT. IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK APPROXIMATE LOCATION OF RELOCATED POLE DUE TO IVY ROAD SIDEWALK PROJECT. LANDSCAPE SHRUB (TYP.) SHRUB (TYP.)5805855775785795815 8 2 583584580 576 577 578 579 581 5 7 0 5 7 5 580 5 6 6 5 6 7 5 6 8 5 6 9 5 7 1 5 7 2 573 5 7 4 57657757 8 579 581 582 583 584 X X REMOVE INLET REMOVE BUILDING AND SURROUNDING LANDSCAPING, CURB, AND SIDEWALK REMOVE BUILDING REMOVE REMOVE SIGNS REMOVE/RELOCATE UTILITY POLES/ GUY WIRES REMOVE SIGNS (TYP.) REMOVE WALL SAWCUT SAWCUT SAWCUT REMOVE INLET AND DOWNSTREAM PORTION OF 12" PVC STORM LINE EASEMENT TO BE ABANDONED (SEE SHEET C8.0) EASEMENT TO REMAIN (SEE SHEET C8.0) REMOVE BOLLARDS (TYP.) REMOVE OVERHEAD POWER LINE REMOVE OVERHEAD POWER LINE ABANDON SANITARY LATERAL AT MANHOLE REMOVE REMOVE REMOVE REMOVE REMOVE REMOVE REMOVE REMOVE REMOVE 6" PVC STORM LINE ABANDON EXISTING GAS SERVICE TO BUILDING ABANDON REMOVE REMOVE ABANDON SANITARY LATERAL AT MANHOLE EASEMENT TO REMAIN (SEE SHEET C8.0) EASEMENT TO EXPIRE UPON COUNTY COMLETION OF IVY ROAD SIDEWALK IMPROVEMENTS CONSTRUCTION REMOVE REMOVE REMOVE REMOVE XXX XX X X X X X X X X X X XXXXXXXXX X X X X SANITARY LATERAL SERVES 2260 IVY ROAD. SERVICE TO BE MAINTAINED THROUGHOUT CONSTRUCTION. REMOVE REMOVE REMOVE CONCRETE REMOVE ASPHALT ASPHALT TO BE MILLED REMOVE TREE/SHRUB SAW CUT LEGEND: X X JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C2.1 - DEMOLITION PLAN.dwg | Plotted on 8/26/2020 10:32 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSDEMOLITION PLANC2.1 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHPMHS TOP=583.74 INV.4"IN=574.95 (NW) INV.8"INPVC=574.74 INV.OUT8"PVC=574.89 MHS TOP=580.64 INV.4"IN= 578.24 INV.IN 2-2"PVC=577.79 INV.8"INPVC= 575.84 INV.OUT=575.76 MHS TOP=579.44 INV.8"IN PVC=573.40 INV.OUT8"IN PVC=566.66 MHS TOP=566.26 INV.8"IN=559.81(W) INV.8"IN=560.30(S) INV.OUT=559.96(E) 8" PV C 8" PVC8" P V C MHS TOP=568.87 INV.4"IN=565.62 (W) INV.4"IN=562.70 (W) INV.3"IN=564.45 (SW) INV.6"IN=566.02 (S) INV.OUT8"IN=562.65 (E)PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP 20' SANITARY SEWER EASEMENT DB 488 PG 624 CURB CURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W EXISTING WATER LINE (TO BE RELOCATED DURING IVY ROAD SIDEWALK IMPROVEMENTS) 8" WATER LINE TO BE CONSTRUCTED BY THE COUNTY AS PART OF THE IVY ROAD SIDEWALK PROJECT. IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK DD D DD 16 14 9 10 18 69' TYP. 18' TYP. 5 10' F R O N T S E T B A C K (PA R K I N G A N D S T R U C T U R E ) 8' 5' 24' TYP. 24' TYP. 24' TYP. 2 STORY MEDICAL OFFICE BUILDING (UNDERGROUND PARKING) ±26,600 SF R5' R5' R15' R10' CONCRETE WHEEL STOP (TYP.)CG-6CG-2 CG-2BOLLARD (TYP.) 8' 24' TYP. R12'±180'SECONDARY ENTRANCE TO IVY ROAD±22 5 ' PRI M A R Y E N T R A N C E T O T W I N SYC A M O R E S L A N E 24' TYP. R15' X X X X X X OPAQUE SCREENING FENCE 91' 154.5' 164.7' 73.7' R30'CG-6±45 0 ' PRI M A R Y E N T R A N C E T O S T I L L F R I E D L A N E ±58 0 ' PRI M A R Y E N T R A N C E T O C O L O N N A D E D R I V E CG-2 CG-2 5'5' CONCRETE SIDEWALK50' REAR SETBACK (STRUCTURE) BUILDING OVERHANG (TYP.) 12' X 25' LOADING SPACE R5' R5' R5' R3' TYP. R2' R5' R5' R1' R2' R2' R3' TYP. R2' R3' R3' TYP. 28' R25' X CURB WIPE DOWN (5) ADA PARKING SIGNS "NO PARKING LOADING ZONE" SIGN (R7-6) R5' R2' R2' R2' CG-12 5' REAR SETBACK (PARKING) - PER SPECIAL EXCEPTION TIE TO COUNTY SIDEWALK PROJECT. ADA RAMP TO REMAIN. 12'8'16'-WIDE DUMPSTER ENCLOSURE 7 9 6 7 18' TYP. 9' TYP. 24' FLUSH CURB ALONG ADA SPACES COORDINATE SIDEWALK CONNECTION WITH IVY ROAD SIDEWALK PROJECT FDC 1.5" WATER METER VAULT 8" x 6" TS&V 1 FHA 6" x 6" TEE WWWWW WWWWWW WATERLINE B 6" DIP WATERLINE A 6" DIP WATERLINE C 6" DIP PORTION OF EXISTING SANITARY SEWER PIPE TO BE REPLACED IN PLACE BY ACSA. CONTRACTOR TO COORDINATE WITH ACSA. IF CONSTRUCTION BEGINS ON SUBJECT PROPERTY PRIOR TO WATER MAIN RELOCATION, CONNECTION SHOULD BE MADE TO EXISTING WATER MAIN.WWWWWW6" x 4" TEE TO 4" THREADED PLUG WATERLINE D 2" COPPER BACKFLOW PREVENTER CONCRETE SIDEWALK HEAVY DUTY CONCRETE HEAVY DUTY ASPHALT LIGHT DUTY ASPHALT MILL AND OVERLAY LEGEND: NOTE: 1.A KNOX BOX SHALL BE INSTALLED. COORDINATE LOCATION WITH THE FIRE MARSHAL'S OFFICE. 2.PAVING/MILL AND OVERLAY AT ENTRANCE WILL REQUIRE FLAGGING OPERATION AND LAND CLOSURES ON IVY ROAD. SEE MOT DETAIL ON SHEET C1.3. 3.FIRE HYDRANT ASSEMBLY, FIRE SUPPRESSION AND WATER SERVICE CONNECTIONS, AND WATER METER VAULTS ARE NOT INCLUDED IN THE IVY ROAD SIDEWALK PROJECT TO BE CONSTRUCTED BY THE COUNTY. BUILDING FOOTPRINT: 1ST FLOOR:±13,300 SF 2ND FLOOR:±13,300 SF TOTAL: ±26,600 SF JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C4.0 - SITE PLAN.dwg | Plotted on 8/26/2020 10:43 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSSITE AND UTILITIES PLANC4.0 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHP8" PV C 8" PVC8" P V C PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP CURB CURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHP8" PV C 8" PVC8" P V C PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP CURB CURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK X X X X X X X 7 9 6 7 57 0 5755805675 6 8 56 9 5 7 1 5 7 2 5735745 7 6 57 7 57 8 579581 582 583 584 GARAGE FFE: 572.0' BUILDING FFE: 583.0'5805785795815825835 7 0 575 580 5665 6 7 5 6 8 5 6 9 5 7 1 5 7 2 5 7 3 5 7 4 576 577 578 579 581 582 571 575 5 7 1 5 7 2 573 574 576 EXISTING TOPOGRAPHY IN THIS AREA BASED ON INFORMATION PROVIDED BY KIMLEY-HORN AND ASSOCIATES FOR THE IVY ROAD SIDEWALK PROJECT. COORDINATION REQUIRED FOR FINAL TIE-INS.5805855775785795815825835845 7 5 571 57 2 57 3 57 4 5 7 6 577 578 579 573574TIE INTO COUNTY SIDEWALK PROJECT. ADA RAMP TO REMAIN. WWWWW WWWWWW WWWWWW8" HDPE RD 1 WITH CLEANOUT TRENCH DRAIN WITH CLEANOUT 600 LF OF 36" UNDERGROUND CMP STORAGE 502 302 202 102D100 WEIR PLATE 402 EX 500 D D D101 103 201 301 8" HDPE RD 2 WITH CLEANOUT 401 501 D 602 601 36" ACCESS RISER WITH VDOT MH-1 TOP 36" ACCESS RISER WITH VDOT MH-1 TOP 36" ACCESS RISER WITH VDOT MH-1 TOP 36" ACCESS RISER WITH VDOT MH-1 TOP INSERTA TEE CONNECTION STORM PIPE TABLE PIPE # RD2 RD 1 101 103 201 301 401 501 601 DIA 8" 8" 12" 12" 12" 12" 12" 12" 12" UPSTREAM INVERT 566.06 576.20 574.00 574.50 574.91 574.66 574.80 565.00 574.81 DOWNSTREAM INVERT 564.95 574.50 573.89 574.00 574.50 574.50 574.50 564.70 574.50 SLOPE 5.00% 5.00% 0.87% 0.82% 0.49% 0.50% 5.00% 0.51% 0.50% LENGTH 22.21 LF 33.93 LF 12.62 LF 61.21 LF 82.06 LF 30.98 LF 5.93 LF 59.34 LF 62.07 LF STORM STRUCTURE TABLE STRUCTURE # EX 500 100 102 202 302 402 502 602 TOP 568.31 577.00 576.75 577.81 579.84 581.96 572.00 577.25 STRUCTURE HEIGHT 3.71' 3.11' 2.75' 2.91' 5.18' 7.16' 7.28' 2.44' DESCRIPTION DI-3B 14 ft Throat MH-1 DI-1 DI-2C 8 ft Throat DI-1 DI-1 6'' Cleanout DI-1 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 PARKING GARAGE ENTRANCE PROFILE 565 570 575 580 585 565 570 575 580 585 9+50 10+00 11+00 PROP. GRADE EXIST. GRADE TRENCH DRAIN PARKING GARAGE (FFE = 572.00') 8 . 5 9% R10' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C5.0 - GRADING AND DRAINAGE PLAN.dwg | Plotted on 8/26/2020 10:33 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSGRADING AND DRAINAGE PLANC5.0 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 620TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHP8" PV C 8" PVC8" P V C PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 620TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHP8" PV C 8" PVC8" P V C PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK X X X X X X X 7 9 6 7 57 0 5755805675 6 8 56 9 5 7 1 5 7 2 5735745 7 6 57 7 57 8 579581 582 583 584 GARAGE FFE: 572.0' BUILDING FFE: 583.0'5805785795815825835 7 0 575 580 5665 6 7 5 6 8 5 6 9 5 7 1 5 7 2 5 7 3 5 7 4 576 577 578 579 581 582 571 575 5 7 1 5 7 2 573 574 576 EXISTING TOPOGRAPHY IN THIS AREA BASED ON INFORMATION PROVIDED BY KIMLEY-HORN AND ASSOCIATES FOR THE IVY ROAD SIDEWALK PROJECT. COORDINATION REQUIRED FOR FINAL TIE-INS.5805855775785795815825835845 7 5 571 57 2 57 3 57 4 5 7 6 577 578 579 575 574 576 577 TC 577.82' TC 578.22' TC 577.90' TC 584.54' TC 584.36' TC 584.58'TC 583.85' TC 583.65' TC 583.00'TC 583.43' TC 582.30'TC 580.70' TC 582.90' TC-BC 582.95' TC 582.50' TC-BC 582.00' TC 572.95' TC 572.50' TC 572.50' FFE=572.00' TC 578.27' TC 579.07' TC 579.29' TC 580.02' TC 581.33' TC 582.18' TC 583.21' TC 582.73' TC 581.37' TC 581.34' TC 580.60' TC 579.65' TC 578.65' EX GND 583.00' EX GND 585.07' EX GND 585.03' EX GND 577.23' EX GND 584.25' FFE= 583.00' TC 578.25' TC 576.94' TC 578.48' TC 582.51' TC 583.16' EX GND 568.11' TC 577.65' TC 576.44' EX GND 570.44' 571.44' 571.23' EX GND 576.80'573574FFE= 572.00' SWK 578.23' SWK 577.16' TC 584.36' TC 584.36' EX GND 568.17' EX GND 569.06' TC 573.43' TC 584.57' TC 577.94' GND 571.81' GND 571.73' TC 572.23' TC 572.31' EX GND 565.03' EX GND 571.14' EX GND 574.79' EX GND 582.52' TC 578.30' 578.00' RIM 577.25' RIM 581.96' RIM 576.75' TIE INTO COUNTY SIDEWALK PROJECT. ADA RAMP TO REMAIN. TC 574.97' 573.60' 571.88' 571.67' 571.88' 571.77' 571.67' 571.85' 571.82' TC 571.87' TC 571.78' SWK 578.58' TC-BC 583.41' TC 573.38' TC 574.90' TC 573.86' WWWWW WWWWWW WWWWWWDD D DD JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C5.0 - GRADING SPOT SHOT PLAN.dwg | Plotted on 8/26/2020 10:33 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSGRADING SPOT SHOT PLANC5.1 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 HEIGHT OF EYE = 3.5 FT EXISTING GRADE HEIGHT OF OBJECT = 3.5 FT FINISHED GRADE HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 TWIN SYCAMORES LANE SIGHT DISTANCE PROFILE 565 570 575 580 585 590 565 570 575 580 585 590 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 IVY ROAD SIGHT DISTANCE PROFILE 550 555 560 565 570 575 580 550 555 560 565 570 575 580 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 168 ' S I G H T D I S T A N C E - R I G H T 280' SIGHT DISTA N C E - L E F T HEIGHT OF OBJECT = 3.5 FT HEIGHT OF OBJECT = 3.5 FT HEIGHT OF OBJECT = 3.5 FT HEIGHT OF EYE = 3.5 FT243' SIGHT DI S T A N C E - L E F T 372' S I G H T D I S T A N C E - R I G H T EXISTING GRADE FINISHED GRADE ASSUMED SPEED = 25 MPH SPEED = 35 MPH GRADE TIE IN TO BE COORDINATED WITH THE VDOT IVY ROAD SIDEWALK PROJECT RD HC SIGN HC SIGN LP SIG N SAN G GGGGGW W W W W SANSANSANSANSAN SAN IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 620OHPOHPOHPOHPOHPOHPOHPS S S VA R I A B L E W I D T H R / W S S SAN UGT 8" D I P SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W X X X X 5' X 57 0 5755805675 6 856 9 5 7 1 5 7 2 5735745 7 6 57 7 57 8 579581 582 583 584580 5785795815825835 7 0 575 580 5665 6 7 5 6 8 5 6 9 5 7 1 5 7 2 5 7 3 5 7 4 576 577 578 579 581 582 571 575 5 7 1 5 7 2 573 574 576 5805855775785795815825835845 7 5 571 57 2 57 3 57 4 5 7 6 577 578 579 573574RD HC SIGN HC SIGN LP SIG N SAN G GGGGGW W W W W SANSANSANSANSAN SAN IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 620OHPOHPOHPOHPOHPOHPOHPS S S VA R I A B L E W I D T H R / W S S SAN UGT 8" D I P SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W14+48.1010+0010+5011+0011+5012+0012+5013+0013+5014+0010+ 0 0 10+ 5 0 11+ 0 0 11+ 5 0 12 + 0 0 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+15. 2 9 280' SIGHT DISTANCE - LEFT168' SIGHT DISTANCE - RIGHT243 ' S I G H T D I S T A N C E - L E F T 372' SI G H T D I S T A N C E - R I G H T SANG GGGW W W W SANSANSANIVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11OHPOHP OHPOHPOHPS VA R I A B L E W I D T H R / W S S 8" D I P SAN SAN SAN 8''W 8''W 8''W 8''W 5' SANG GGGW W W W SANSANSANIVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11OHPOHP OHPOHPOHPS VA R I A B L E W I D T H R / W S S 8" D I P SAN SAN SAN 8''W 8''W 8''W 8''W JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C5.1 - SIGHT DISTANCE PROFILES.dwg | Plotted on 8/26/2020 10:34 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSSIGHT DISTANCE PROFILESC5.2 1" = 30' 0 SCALE 1"=30' 60'30'NAD 83PROFILE SCALE 0 0 50 5 SIGHT DISTANCE PLAN PARKING GARAGE - AUTOTURN ANALYSIS HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 STR 302 - UG DETENTION 560 565 570 575 580 585 560 565 570 575 580 585 9+50 10+00 11+00 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 STR 202 - UG DETENTION 560 565 570 575 580 585 560 565 570 575 580 585 9+50 10+00 11+00 11+50 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 STR 402 - UG DETENTION 565 570 575 580 585 590 565 570 575 580 585 590 9+50 10+00 11+00 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 STR 502 - EX STR 500 555 560 565 570 575 580 555 560 565 570 575 580 9+50 10+00 11+00 301 30.98' OF 12" HDPE @ 0.50% PROP. GRADE 302: DI-1 STA 10+03.28 TOP 579.84 INV OUT 574.66 (301)402: DI-1STA 10+02.15TOP 581.96INV OUT 574.80 (401)PROP. GRADE EXIST. GRADE EXIST. GRADE PROP. GRADE 502: 6'' CleanoutSTA 10+01.78TOP 572.00INV OUT 565.00 (501)EX 500: DI-3B 14 ft ThroatSTA 10+61.12TOP 568.31INV IN 564.70 (501)PROP. GRADE EXIST. GRADE 401 5.93' OF 12" HDPE @ 5.00% 501 59.34' OF 12" HDPE @ 0.51% HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 UG DETENTION - STR 100 560 565 570 575 580 585 560 565 570 575 580 585 APPROX. LOCATION OF 8" WATERLINE. EXISTING WATERLINE IS TO BE RELOCATED WITH IVY ROAD SIDEWALK IMPROVEMENTS. CONTRACTOR TO FIELD VERIFY LOCATION. 9+50 10+00 11+00 11+50 103 61.21' OF 12" HDPE @ 0.82% 102: DI-1 STA 10+63.62 TOP 576.75 INV IN 574.00 (103) INV OUT 574.00 (101) 100: MH-1 STA 10+76.24 TOP 577.00 INV IN 573.89 (101) 36" CMP EXIST. GRADE PROP. GRADE 1.5' MIN. HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 STR 602 - UG DETENTION 560 565 570 575 580 585 560 565 570 575 580 585 PROP. GRADE EXIST. GRADE 101 12.62' OF 12" HDPE @ 0.87% 201 82.06' OF 12" HDPE @ 0.49% 36" CMP 36" CMP 36" CMP 36" CMP1.7' 1.7' 3' MIN. 3' MIN. 2.5' 1.5' EXIST. 12" RCP EXIST. GRADE EXISTING GAS LINE. LOCATION AND DEPTH TO BE FIELD VERIFIED. 9+50 10+00 11+00 11+50 601 62.07' OF 12" HDPE @ 0.50%602: DI-1STA 10+01.73TOP 577.25INV OUT 574.81 (601)202: DI-2C 8 ft ThroatSTA 10+00.06TOP 577.81INV OUT 574.91 (201)HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 SANITARY - BLDG TO MAIN 555 560 565 570 575 580 585 555 560 565 570 575 580 585 9+50 10+00 11+00 11+50 2STA 10+13.41 TOP 579.59 INV IN 567.54 (BLDG-2) INV OUT 567.44 (2-1) 2-1 19.00' OF 6" PVC @ 1.00% BLDG-2 13.41' OF 6" PVC @ 1.00% LOWER STRUCTURE TOP OF EX. MANHOLE TO 577.75 PROPOSED GARAGE PROPOSED BUILDING 1 STA 10+32.41 TOP 579.45 INV IN 573.40 (EX.3-1) INV IN 567.25 (2-1) INV OUT 566.66 (1-EX.1) EXISTING GRADE PROPOSED GRADE HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 WATERLINE 'A' - SERVICE 555 560 565 570 575 580 585 590 555 560 565 570 575 580 585 590 9+50 10+00 11+00 12+00 12+50 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 WATERLINE 'D' - DOMESTIC SERVICE 555 560 565 570 575 580 585 590 555 560 565 570 575 580 585 590 HORIZ SCALE: 1"=50' VERT SCALE: 1"=5 WATERLINE 'C' - FIRE SERVICE 555 560 565 570 575 580 585 590 555 560 565 570 575 580 585 590 EXISTING GRADE PROPOSED GRADE 6" CLASS 52 DIP WATERLINE 6"x6" TEE; WATERLINE 'C'45° BEND; FHA ASSEMBLY8" X 6" TS&V45° BEND6" GATE VALVE6"x4" TEE; WATERLINE 'D'6" GATE VALVEHORIZ SCALE: 1"=50' VERT SCALE: 1"=5 WATERLINE 'B' - FDC SERVICE 560 565 570 575 580 585 590 595 560 565 570 575 580 585 590 595 9+50 10+00 11+00 EXISTING GRADE PROPOSED GRADE 6" CLASS 52 DIP WATERLINE 3.5' MIN. CONNECTION TO EXISTING WATERLINE. VERIFY LOCATION AND ELEVATION.FDC SIAMESE CONNECTIONTIE TO PROPOSED BUILDING9+50 10+00 11+00 9+50 10+00 11+00 11+50 PROPOSED GRADE 3.5' MIN.6"X6" TEE; WATERLINE 'A'EXISTING GRADE 6" CLASS 52 DIP WATERLINE TIE TO PROPOSED BUILDING2" TYPE K COPPER LINE EXISTING GRADE PROPOSED GRADE 6"X4" TEE TO 4" PLUG;WATERLINE 'A'TIE TO PROPOSED BUILDING4" GATE VALVEWATER METER VAULT EX. GAS MAIN APPROX. LOCATION OF EX. GAS MAIN. CONTRACTOR TO FIELD VERIFY DEPTH AND LOCATION. EX. GAS MAIN EX. GAS MAIN 45° BEND90° BEND90° BEND3.5' MIN.90° BEND1' MIN. 3.5' MIN. 1' MIN.6" GATE VALVEWATERLINE 'D'90° BENDBACKFLOW PREVENTER 90° BENDJOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C7.0 STORM AND UTILITY PROFILES.dwg | Plotted on 8/26/2020 10:34 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSSTORM AND UTILITY PROFILESC7.0 1" = 30' PROFILE SCALE 0 0 50 5 RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHPMHS TOP=583.74 INV.4"IN=574.95 (NW) INV.8"INPVC=574.74 INV.OUT8"PVC=574.89 MHS TOP=580.64 INV.4"IN= 578.24 INV.IN 2-2"PVC=577.79 INV.8"INPVC= 575.84 INV.OUT=575.76 MHS TOP=579.44 INV.8"IN PVC=573.40 INV.OUT8"IN PVC=566.66 MHS TOP=566.26 INV.8"IN=559.81(W) INV.8"IN=560.30(S) INV.OUT=559.96(E) 8" PV C 8" PVC8" P V C MHS TOP=568.87 INV.4"IN=565.62 (W) INV.4"IN=562.70 (W) INV.3"IN=564.45 (SW) INV.6"IN=566.02 (S) INV.OUT8"IN=562.65 (E)PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP 20' SANITARY SEWER EASEMENT DB 488 PG 624 CURB CURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK RD HC SIGN HC SIGN LP SIG N SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN TMP 06000-00-00-03700 JOSEPH W. & MARY JANE TEAGUE DB 775 PG 154 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (FUNERAL HOME) TMP 06000-00-00-03600 300 TWIN SYCAMORES LANE LLC DB 3995 PG 533 ZONE: COMMERCIAL OFFICE USE: COMMERCIAL (OFFICE) TMP 06000-00-00-036A0 STILLFRIED LANE LLC DB 4709 PG 224 ZONE: R1 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) TMP 06000-00-00-040C5 CHARLOTTESVILLE INVESTMENT PROPERTIES DB 860 PG 568 ZONE: R15 RESIDENTIAL USE: RESIDENTIAL (MULTIFAMILY) IVY R O A D ( R O U T E 2 5 0 )TWIN SYCAMORES LANE (PRIVATE)21' ROAD ESMT PLAT DB 488 PG 62020' ROAD RW DB 248 PG. 11 TMP 06000-00-00-03800 2246-2248 IVY ROAD LLC DB 1805 PG 670 1.42 ACRES FROM RECORDED PLAT 2246 IVY ROADOHPOHPOHPOHPOHP OHPOHPOHPOHPOHPMHS TOP=583.74 INV.4"IN=574.95 (NW) INV.8"INPVC=574.74 INV.OUT8"PVC=574.89 MHS TOP=580.64 INV.4"IN= 578.24 INV.IN 2-2"PVC=577.79 INV.8"INPVC= 575.84 INV.OUT=575.76 MHS TOP=579.44 INV.8"IN PVC=573.40 INV.OUT8"IN PVC=566.66 MHS TOP=566.26 INV.8"IN=559.81(W) INV.8"IN=560.30(S) INV.OUT=559.96(E) 8" PV C 8" PVC8" P V C MHS TOP=568.87 INV.4"IN=565.62 (W) INV.4"IN=562.70 (W) INV.3"IN=564.45 (SW) INV.6"IN=566.02 (S) INV.OUT8"IN=562.65 (E)PAVEMENTPAV E M E N T POLE PPF1 POLE PPF1 POLE PP F5X POLE PPF1 SD INLET TOP=576.19 INV.IN 12"RCP=573.79 INV.OUT 12"RCP=573.72 POLE PP POLE PP 20' SANITARY SEWER EASEMENT DB 488 PG 624 CURB CURB TEMP. EASEMENT FOR CONSTRUCTION OF CURB AND SLOPES AND ENTRANCE SEE DB 5144 PG 303 PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 766 PERMANENT VDOT UTILITY EASEMENT TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 12" STONE WALL S S S VA R I A B L E W I D T H R / W S S PP SAN SAN UG T UG T 8" D I P TMP 06000-00-00-03900 WEST END SHOPS-EAST LLC DB 1805 PG 664 ZONE: HIGHWAY COMMERCIAL USE: COMMERCIAL (NEIGHBORHOOD SHOPPING CENTER) SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W IPF IPF BENT ROD /F ROD /F TREE LINETREE LINEBENCHMARK BENCHMARK BENCHMARK BENCHMARK X X X X X X X 7 9 6 7 WWWWW WWWWWW PORTION OF EXISTING SANITARY SEWER PIPE TO BE REPLACED IN PLACE BY ACSA. CONTRACTOR TO COORDINATE WITH ACSA.WWWWWWDD D DD STORMWATER FACILITY EASEMENT DB 5359 PG 212 24' PRIVATE VARIABLE WIDTH SHARED ACCESS EASEMENT DB 5359 PG 212 STORMWATER ACCESS EASEMENT DB 5359 PG 212 10' TYP. PRIVATE VARIABLE WIDTH SHARED ACCESS EASEMENT DB 5359 PG 212 HEREBY ABANDONED PERMANENT DOMINION ENERGY EASEMENT SEE DB 5134 PG 786 EASEMENT TO REMAIN EASEMENT TIMING TO BE COORDINATED WITH COUNTY EASEMENT TO EXPIRE UPON COUNTY COMLETION OF IVY ROAD SIDEWALK IMPROVEMENTS CONSTRUCTION 20' ACSA WATERLINE EASEMENT 20' SANITARY SEWER EASEMENT DB 488 PG 624 PORTION OF EXISTING SANITARY SEWER PIPE TO BE REPLACED IN PLACE BY ACSA. CONTRACTOR TO COORDINATE WITH ACSA. EASEMENT TO REMAIN TEMP. EASEMENT FOR ENTRANCE SEE DB 5134 PG 766 ACCESS EASEMENT STORMWATER FACILITY EASEMENT STORMWATER ACCESS EASEMENT ACSA WATERLINE EASEMENT LEGEND: JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 C8.0 EASEMENT PLAN.dwg | Plotted on 8/26/2020 10:35 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSEASEMENT PLANC8.0 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 PRIVATE VARIABLE WIDTH SHARED ACCESS EASEMENT DB 5359 PG 212 PRIVATE VARIABLE WIDTH SHARED ACCESS EASEMENT DB 5359 PG 212 20' ACSA WATERLINE EASEMENT 57 0 5755805675 6 856 9 5 7 1 5 7 2 5735745 7 6 57 7 57 8 579581 582 583 584580 5785795815825835 7 0 575 580 56656 7 5 6 8 5 6 9 5 7 1 5 7 2 5 7 3 5 7 4 576 577 578 579 581 582 571 575 5 7 1 5 7 2 573 574 576 5805855775785795815825835845 7 5 571 57 2 57 3 57 4 5 7 6 577 578 579 573574SAN SAN G G GGGGGGGG W W W W W W W W SANSANSANSANSANSANSAN SAN SAN S S S S S SAN SAN UG T UG T 8" D I P SAN SAN SAN SAN SAN SAN SAN SAN 8''W 8''W 8''W 8''W 8''W 8''W 8''W TREE LINETREE LINEDD D DD X X X X X X X 7 9 6 7 WWWWW WWWWWW WWWWWW202' I V Y R O A D TWIN SYCAMORES LANE (PRIVATE)PROPOSED BUILDING WITH UNDERGROUND PARKING (4) CER FOR (4) COR FLO (2) CER FOR (4) BET HER (3) GIN PRI (6) NYS SYL (1) COR FLO (12) ILE WIN (14) ILE GLA (9) ACE BON (9) ILE GLA (10) QUE PHE TREES BOTANICAL NAME ACE BON ACER SACCHARUM CBONFIREC BET HER BETULA NIGRA CHERITAGEC GIN PRI GINKGO BILOBA CPRINCETON SENTRYC NYS SYL NYSSA SYLVATICA QUE PHE QUERCUS PHELLOS FLOWERING TREES BOTANICAL NAME CER FOR CERCIS CANADENSIS CFOREST PANSYC TM COR FLO CORNUS FLORIDA SHRUBS BOTANICAL NAME ILE GLA ILEX GLABRA ILE WIN ILEX VERTICILLATA PLANT SCHEDULE X X X PARKING LOT LANDSCAPING 2,109 SF - INTERIOR PARKING LOT LANDSCAPE AREA SCALE: 1" = 40' JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 L1.0 - LANDSCAPE PLAN.dwg | Plotted on 8/26/2020 10:59 AM | by Kim MellonM. RACHNER M. RACHNER F. HANCOCK 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA43567MOMOCNo. 1491 FRANK W. HANCOCK III THEALWN I V RIG NIOF ALANDS CAPE A R C H ITECT08/26/20 02/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSLANDSCAPE PLANL1.0 1" = 20' 0 SCALE 1"=20' 40'20'NAD 83 CANOPY SF 214 464 17 419 124 124 TREES QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE ROOT ACE BON 9 ACER SACCHARUM CBONFIREC BONFIRE SUGAR MAPLE 2.5" CAL.B&B BET HER 4 BETULA NIGRA CHERITAGEC HERITAGE RIVER BIRCH 2.5" CAL.B&B GIN PRI 3 GINKGO BILOBA CPRINCETON SENTRYC PRINCETON SENTRY GINKGO 2.5" CAL.B&B NYS SYL 6 NYSSA SYLVATICA SOUR GUM 3.5" CAL.B&B QUE PHE 10 QUERCUS PHELLOS WILLOW OAK 2.5" CAL.B&B FLOWERING TREES QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE ROOT CER FOR 6 CERCIS CANADENSIS CFOREST PANSYC TM FOREST PANSY REDBUD 6C-8C HT.B&B COR FLO 5 CORNUS FLORIDA EASTERN DOGWOOD 6C-8C HT.B&B SHRUBS QTY BOTANICAL NAME COMMON NAME MIN. INSTALLED SIZE ROOT ILE GLA 23 ILEX GLABRA INKBERRY HOLLY 24" HT./SPRD.CONTAINER ILE WIN 12 ILEX VERTICILLATA WINTERBERRY 24" HT./SPRD.CONTAINER 2020-03-19 16:47 PLANT SCHEDULE 181 TREE COVER CALCULATIONS * per Sec. 32.7.9.8 of the Albemarle County Code SITE AREA REQUIREMENT CALCULATION REQUIRED QUANTITY PROVIDED QUANTITY 1.42 AC (GROSS SITE AREA)10% COVER 1.42 AC x .1 = 0.142 AC = 6,205 SF 6,204 SF 9,430 SF INTERIOR PARKING LOT LANDSCAPE AREA REQUIREMENTS * per Sec. 32.7.9.6 of the Albemarle County Code REQUIREMENT PARKING LOT AREA CALCULATIONS REQUIRED PROVIDED 5% GROSS PARKING AREA 40,381 SF 40,381 x .05 = 2,019 SF 2,019 SF 2,109 SF LANDSCAPING OF PARKING AREAS * per Albemarle County ARB DESIGN GUIDELINES REQUIREMENT PARKING LOT SPACES CALCULATIONS REQUIRED PROVIDED 1 LG. SHADE TREE PER 10 PARKING SPACES 78 PARKING SPACES 78/10 = 7.8 8 LG. OR SHADE TREES 8 LARGE SHADE TREES NOTE: -WHERE A PARKING AREA IS LOCATED SO THAT PARKED CARS ARE VISIBLE FROM AN OFF-SITE STREET, SHRUBS ARE TO BE INSTALLED AT A MINIMUM HEIGHT OF 12". -ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. LANDSCAPING ALONG INTERIOR STREETS * per Albemarle County ARB DESIGN GUIDELINES STREET LENGTH REQUIREMENTS CALCULATIONS REQUIRED PROVIDED TWIN SYCAMORES LANE 296 LF 1 LG TREE PER 40 LF 296/40 = 7.4 8 LARGE TREES 8 LARGE TREES LANDSCAPING ALONG THE FRONTAGE OF E.C. STREETS * per Albemarle County ARB DESIGN GUIDELINES STREET LENGTH REQUIREMENTS CALCULATIONS REQUIRED PROVIDED IVY ROAD 202 LF 1 LG TREE PER 35 LF WITH INTERSPERSED FLOWERING TREES 202/35 = 5.8 6 LARGE TREES 6 LARGE TREES 8 FLOWERING TREES LANDSCAPE NOTES AND DETAILSL2.0 N/A JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 L2.0 - LANDSCAPE NOTES AND DETAILS.dwg | Plotted on 8/26/2020 10:59 AM | by Kim MellonM. RACHNER M. RACHNER F. HANCOCK 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA43567MOMOCNo. 1491 FRANK W. HANCOCK III THEALWN I V RIG NIOF ALANDS CAPE A R C H ITECT08/26/20 02/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSGENERAL NOTES PRE-CONSTRUCTION ·CONTRACTOR IS RESPONSIBLE FOR CONTACTING "MISS UTILITY" AT 1.800.552.7001 FOR LOCATION OF ALL UTILITY LINES.TREES SHALL BE LOCATED A MINIMUM OF 5 FEET FROM SEWER/WATER CONNECTIONS. NOTIFY LANDSCAPE ARCHITECT OF CONFLICTS. ·VERIFY ALL PLANT MATERIAL QUANTITIES ON THE PLAN PRIOR TO BIDDING, PLANT LIST TOTALS ARE FOR CONVENIENCE ONLY AND SHALL BE VERIFIED PRIOR TO BIDDING. ·PROVIDE PLANT MATERIALS OF QUANTITY, SIZE, GENUS, SPECIES, AND VARIETY INDICATED ON PLANS. ALL PLANT MATERIALS AND INSTALLATION SHALL COMPLY WITH RECOMMENDATIONS AND REQUIREMENTS OF ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK". IF SPECIFIED PLANT MATERIAL IS NOT OBTAINABLE, SUBMIT PROOF OF NON AVAILABILITY TO THE ARCHITECTS, TOGETHER WITH PROPOSAL FOR USE OF EQUIVALENT MATERIAL. ·PROVIDE AND INSTALL ALL PLANTS AS IN ACCORDANCE WITH DETAILS AND CONTRACT SPECIFICATIONS CONSTRUCTION/INSTALLATION ·LANDSCAPE ARCHITECT RESERVES THE RIGHT TO REJECT ANY PLANTS AND MATERIALS THAT ARE IN AN UNHEALTHY OR UNSIGHTLY CONDITION, AS WELL AS PLANTS AND MATERIALS THAT DO NOT CONFORM TO ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK" ·LABEL AT LEAST ONE TREE AND ONE SHRUB OF EACH VARIETY AND CALIPER WITH A SECURELY ATTACHED, WATERPROOF TAG BEARING THE DESIGNATION OF BOTANICAL AND COMMON NAME. ·INSTALL LANDSCAPE PLANTINGS AT ENTRANCES/EXITS AND PARKING AREAS ACCORDING TO PLANS SO THAT MATERIALS WILL NOT INTERFERE WITH SIGHT DISTANCES. ·CONTRACTOR IS RESPONSIBLE FOR WATERING ALL PLANT MATERIAL DURING INSTALLATION AND UNTIL FINAL INSPECTION AND ACCEPTANCE BY OWNER. CONTRACTOR SHALL NOTIFY OWNER OF CONDITIONS WHICH AFFECTS THE GUARANTEE. INSPECTIONS/GUARANTEE ·UPON COMPLETION OF LANDSCAPE INSTALLATION, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR WHO WILL VERIFY COMPLETENESS, INCLUDING THE REPLACEMENT OF ALL DEAD PLANT MATERIAL. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING A FINAL INSPECTION BY THE LANDSCAPE ARCHITECT. ·ALL EXTERIOR PLANT MATERIALS SHALL BE GUARANTEED FOR ONE FULL YEAR AFTER DATE OF FINAL INSPECTION AGAINST DEFECTS INCLUDING DEATH AND UNSATISFACTORY GROWTH. DEFECTS RESULTING FROM NEGLECT BY THE OWNER, ABUSE OR DAMAGE BY OTHERS, OR UNUSUAL PHENOMENA OR INCIDENTS WHICH ARE BEYOND THE CONTRACTORS CONTROL ARE NOT THE RESPONSIBILITY OF THE CONTRACTOR ·PLANT MATERIAL QUANTITIES AND SIZES WILL BE INSPECTED FOR COMPLIANCE WITH APPROVED PLANS BY A SITE PLAN REVIEW AGENT OF THE PLANNING DEPARTMENT PRIOR TO THE RELEASE OF THE CERTIFICATE OF OCCUPANCY. ·REMOVE ALL GUY WIRES AND STAKES 12 MONTHS AFTER INSTALLATION. PLAN VIEW NOTE: ONLY STAKE TREES WITH LARGE CROWNS, 2" CALIPER OR GREATER, IF LOCATED ON WINDY SITES, OR WHERE TAMPERING MAY OCCUR. PRUNE CODOMINATE LEADERS REMOVE BROKEN, BADLY DEFORMED, RUBBING, NARROW CROTCH ANGLES, WATER SPROUTS, OR CROSS-BRANCHES. REMOVE TAGS, LABELS, AND PLASTIC SLEEVING. DO NOT STAKE UNLESS SPECIFIED (SEE NOTE) DO NOT WRAP TRUNK PRUNE SUCKERS IF FIELD GROWN, CUT AWAY ALL BALLING ROPES. REMOVE BURLAP OR WIRE BASKET FROM TOP 13 OF BALL. IF CONTAINER GROWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS 1:1 SLOPE OF SIDES OF PLANTING HOLE SCARIFY SIDES BEFORE PLANTING PLACE ROOTBALL ON UNEXCAVATED OR TAMPED SOIL TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOTBALL DOES NOT SHIFT 1" COMPOST LAYER 6" SAUCER BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER SET ROOTBALL FLUSH TO GRADE OR 1-2" HIGHER IN SLOWLY DRAINING SOILS. DO NOT COVER THE TOP OF THE ROOTBALL WITH SOIL. ROOTFLARE SHALL BE VISIBLE ABOVE FINISHED GRADE 2-3" MULCH LAYER TO EDGE OF DRIPLINE. KEEP 4-6" AWAY FROM TRUNKFLARE 8' 2"x2" HARDWOOD STAKE, 2'-6" MIN BELOW SURFACE. STAKE SHALL BE DRIVEN A MIN 18" OUT FROM TRUNK AND OUTSIDE OF ROOTBALL GALVANIZED WIRE GUY 12 GAUGE. ALLOW FOR A SLIGHT AMOUNT OF MOVEMENT 3-2"x2" HARDWOOD STAKES 12 GAUGE GALVANIZED WIRE ROOT BALL 3 X ROOTBALL DIAMETER 1 DECIDUOUS TREE - STAKING SPECIFIED NOT TO SCALE 2 MULTI-STEM TREE - STAKING SPECIFIED NOT TO SCALE PLAN VIEW ROOT BALL 3- 2" x 2" HARDWOOD STAKES 12 GAUGE GALVANIZED WIRE 12 GAUGE GALVANIZED WIRE ALLOW FOR SLIGHT MOVEMENT SET ROOTBALL FLUSH TO GRADE OR 1-2" HIGHER IN SLOWLY DRAINING SOILS. DO NOT COVER THE TOP OF THE ROOTBALL WITH SOIL. ROOTFLARE SHALL BE VISIBLE ABOVE FINISHED GRADE PRUNE SUCKERS 1:1 SLOPE ON SIDES OF PLANTING HOLE SCARIFY SIDES BEFORE PLANTING PLACE ROOTBALL ON UNEXCAVATED OR TAMPED SOIL TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOTBALL DOES NOT SHIFT IF FIELD GROWN CUT AWAY ALL BALLING ROPES. REMOVE BURLAP OR WIRE BASKET FROM TOP 13 OF BALL. IF CONTAINER GROWN, REMOVE CONTAINER AND CUT CIRCLING ROOTS 6" SAUCER 1" COMPOST LAYER BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER 2-3" MULCH LAYER TO EDGE OF DRIPLINE. KEEP 4-6" AWAY FROM TRUNK FLARE PRUNE BROKEN BRANCHES REMOVE TAGS, LABELS AND PLASTIC SLEEVING DO NOT WRAP TRUNK DO NOT PRUNE TERMINAL LEADER OR BRANCH TIPS NEW 1/2" RUBBER HOSE 3 2x2 HARDWOOD STAKES, 2'-6" MIN BELOW SURFACE. STAKE SHALL BE DRIVEN A MIN. 18" OUT FROM TRUNK AND OUTSIDE OF ROOTBALL 3 X ROOTBALL DIAMETER B&B CONTAINER REMOVE ALL STRING, WIRE, AND BURLAP FROM TOP 13 OF BALL REMOVE ALL DEAD, BROKEN, DISEASED, AND WEAK BRANCHES AT TIME OF PLANTING INSTALL SHRUBS SO THAT THE TOP OF THE ROOTBALL IS AT THE SAME GRADE AS ORIGINALLY GROWN OR 1-2" ABOVE IN POOR DRAINING SOILS. DO NOT COVER THE TOP OF THE ROOTBALL WITH SOIL 2-3" MULCH LAYER, KEEP AWAY FROM TRUNK 1" COMPOST LAYER PROVIDE MULCH UP AND OVER SAUCER 6" SAUCER REMOVE CONTAINER. SCARIFY PERIMETER ROOTS BACKFILL PLANTING PIT WITH NATIVE SOIL. INCORPORATE SLOW-RELEASE GRANULAR FERTILIZER SCARIFY BOTTOM AND SIDES OF PIT 3 SHRUB PLANTING NOT TO SCALE JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICES:\103\43567-Ivy_Beaver\DWG\Sheet\CD\43567 L3.0 - ARCH ELEVATIONS.dwg | Plotted on 8/26/2020 10:36 AM | by Kim MellonK. MELLON K. MELLON C. KOTARSKI 11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA4356702/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/26/2020COUNTY COMMENTSARCHITECTURAL ELEVATIONSL3.0 N/A ARCHITECTURAL ELEVATIONS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY, NOT TO SCALE X X X X X X X 8" D I P 6 6 6 6 6 6 6 6 &$/&8/$7('/,*+7,1*/(9(/ 32,17$7//)7<3821 6 6 6 6 6 3523(57</,1(7<3821 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.6 0.7 0.6 0.6 0.6 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.4 1.5 1.5 1.4 1.2 1.0 0.9 0.7 0.6 0.5 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.3 0.5 0.6 0.9 1.2 1.5 1.9 2.3 2.5 2.4 2.2 1.9 1.5 1.2 0.9 0.8 0.6 0.6 0.5 0.6 0.6 0.6 0.6 0.7 0.6 0.6 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.5 0.5 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.4 0.6 0.8 1.1 1.6 2.2 2.9 3.6 3.9 3.9 3.5 2.9 2.2 1.7 1.3 1.0 0.8 0.7 0.7 0.7 0.8 0.9 0.9 1.0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.8 1.4 1.4 0.8 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.5 0.7 1.0 1.4 2.1 3.1 4.3 5.4 6.0 5.3 4.2 3.2 2.3 1.6 1.2 1.0 0.9 0.9 1.0 1.1 1.3 1.4 1.5 1.5 1.4 1.2 1.0 0.8 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.4 1.6 3.8 3.5 1.5 0.5 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.5 0.8 1.2 1.8 2.7 4.1 5.7 7.2 7.9 7.2 5.8 4.2 2.9 2.0 1.5 1.2 1.1 1.2 1.3 1.6 1.9 2.2 2.3 2.3 2.1 1.8 1.5 1.1 0.8 0.6 0.5 0.3 0.3 0.2 0.1 0.0 0.0 2.0 7.0 6.1 1.7 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.6 0.9 1.3 2.0 3.1 4.8 6.7 7.9 8.0 8.5 7.2 5.2 3.5 2.3 1.7 1.4 1.3 1.5 1.8 2.3 2.8 3.4 3.7 3.7 3.3 2.8 2.1 1.6 1.1 0.8 0.6 0.4 0.3 0.2 0.2 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.4 0.6 0.9 1.4 2.2 3.4 5.2 7.2 8.9 7.9 5.7 3.8 2.5 1.8 1.6 1.6 1.8 2.4 3.2 4.2 5.1 5.7 5.0 4.1 3.1 2.2 1.5 1.0 0.7 0.5 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.3 0.5 0.7 0.9 1.4 2.2 3.4 5.1 7.1 9.0 7.7 5.5 3.7 2.6 1.9 1.7 1.8 2.2 3.0 4.3 5.8 7.2 7.8 7.1 5.7 4.2 2.8 1.9 1.2 0.8 0.6 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.5 0.7 0.9 1.4 2.1 3.1 4.6 6.5 8.0 8.8 8.2 6.6 4.8 3.3 2.4 1.9 1.7 2.0 2.6 3.6 5.3 7.4 8.8 7.3 5.3 3.5 2.2 1.4 0.9 0.6 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.5 0.7 0.9 1.3 1.9 2.7 3.9 5.3 6.6 7.2 6.4 5.2 3.9 2.8 2.1 1.8 1.7 2.0 2.7 4.0 6.0 8.2 9.1 8.2 6.0 3.9 2.4 1.5 1.0 0.7 0.4 0.3 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.5 0.7 0.9 1.2 1.7 2.4 3.2 4.1 4.9 5.4 5.3 4.7 3.9 3.1 2.4 1.9 1.7 1.7 2.0 2.7 4.0 5.9 8.2 9.2 9.1 8.2 6.0 3.9 2.5 1.6 1.0 0.7 0.5 0.3 0.0 0.5 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.5 0.7 0.9 1.2 1.6 2.1 2.7 3.3 3.8 4.0 3.9 3.5 3.0 2.5 2.0 1.7 1.6 1.6 1.9 2.5 3.6 5.3 7.3 8.8 9.2 8.9 7.4 5.3 3.6 2.3 1.5 1.0 0.7 0.5 3.2 2.0 0.8 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.3 0.4 0.5 0.7 0.9 1.2 1.6 2.0 2.5 3.0 3.3 3.4 3.3 3.0 2.6 2.2 1.9 1.6 1.5 1.5 1.7 2.2 3.1 4.3 5.8 7.2 8.0 7.3 5.9 4.3 3.0 2.0 1.4 1.0 0.7 0.5 5.1 3.5 1.3 0.4 0.2 0.1 0.0 0.0 0.0 0.3 0.4 0.6 0.8 1.0 1.3 1.7 2.2 2.7 3.1 3.4 3.4 3.3 3.0 2.6 2.2 1.8 1.6 1.4 1.4 1.6 2.0 2.6 3.4 4.4 5.3 5.9 5.9 5.3 4.3 3.3 2.4 1.8 1.4 1.0 0.8 0.5 4.5 2.5 1.1 0.4 0.2 0.1 0.0 0.0 0.0 0.3 0.5 0.6 0.8 1.1 1.5 2.0 2.5 3.1 3.6 3.9 4.0 3.8 3.4 2.9 2.4 1.9 1.6 1.4 1.4 1.5 1.7 2.1 2.7 3.3 3.8 4.2 4.1 3.8 3.2 2.6 2.0 1.6 1.4 1.4 1.1 0.7 0.7 1.3 1.1 0.6 0.3 0.1 0.1 0.0 0.0 0.0 0.4 0.5 0.6 0.9 1.2 1.7 2.3 3.0 3.8 4.4 4.8 4.5 4.0 3.4 2.7 2.1 1.7 1.5 1.3 1.4 1.6 1.8 2.2 2.7 3.0 3.2 3.2 2.9 2.5 2.1 1.8 1.6 1.8 2.3 2.4 1.4 0.5 0.6 0.5 0.3 0.2 0.1 0.0 0.0 0.0 0.3 0.4 0.5 0.7 1.0 1.3 1.9 2.6 3.5 4.4 5.1 5.4 5.3 4.8 4.0 3.1 2.4 1.9 1.5 1.3 1.3 1.5 1.7 2.1 2.5 2.8 2.9 2.8 2.5 2.2 1.9 1.7 1.7 2.4 4.4 6.6 1.4 0.8 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.3 0.4 0.5 0.7 1.0 1.4 2.0 2.9 3.9 4.8 5.2 5.2 5.6 5.4 4.6 3.5 2.6 2.0 1.6 1.4 1.3 1.4 1.7 2.1 2.6 2.9 3.1 2.9 2.6 2.2 1.9 1.7 1.8 2.9 6.7 14.0 3.7 1.4 0.5 0.2 0.1 0.1 0.0 0.0 0.0 0.3 0.4 0.5 0.7 1.0 1.5 2.1 3.0 4.1 4.9 5.5 5.7 4.9 3.7 2.7 2.0 1.6 1.3 1.3 1.4 1.7 2.2 2.9 3.6 3.4 2.9 2.4 2.0 1.7 1.9 2.7 5.3 9.1 6.5 3.7 1.5 0.5 0.2 0.1 0.0 0.0 0.0 0.3 0.4 0.5 0.7 1.0 1.5 2.1 3.0 4.1 4.9 4.9 5.6 5.7 4.8 3.7 2.7 2.0 1.5 1.3 1.3 1.4 1.7 2.2 4.3 4.0 3.3 2.6 2.1 1.8 1.9 2.1 2.6 2.6 0.0 2.1 1.7 0.9 0.3 0.2 0.1 0.0 0.0 0.0 0.3 0.4 0.5 0.7 1.0 1.4 2.0 2.8 3.8 4.8 5.4 5.6 5.7 5.3 4.4 3.4 2.5 1.8 1.4 1.3 1.2 1.3 1.5 2.0 4.0 4.7 4.5 3.8 2.9 2.3 1.9 2.0 2.1 1.9 1.1 0.2 0.5 0.6 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.3 0.3 0.5 0.6 0.9 1.3 1.8 2.5 3.4 4.3 5.0 5.5 5.2 4.6 3.7 2.9 2.1 1.6 1.3 1.2 1.2 1.3 1.5 1.8 4.9 4.8 3.9 3.0 2.4 2.1 2.4 3.3 3.4 0.1 0.1 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.2 0.3 0.4 0.6 0.8 1.1 1.5 2.1 2.8 3.5 4.1 4.5 4.5 4.2 3.6 3.0 2.3 1.8 1.4 1.2 1.1 1.1 1.3 1.6 2.1 4.1 4.9 4.7 3.8 2.9 2.3 2.3 3.2 6.5 9.8 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.2 0.3 0.4 0.5 0.7 0.9 1.2 1.7 2.1 2.6 3.1 3.3 3.3 3.1 2.7 2.2 1.8 1.4 1.2 1.0 1.0 1.1 1.3 1.7 2.4 4.2 4.5 4.1 3.3 2.6 2.1 2.2 3.5 8.1 14.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.3 0.4 0.6 0.8 1.0 1.3 1.6 1.9 2.2 2.3 2.3 2.2 1.9 1.7 1.4 1.1 1.0 0.9 0.9 1.0 1.3 1.7 3.6 3.7 3.3 2.7 2.2 1.8 1.8 2.6 4.6 6.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.2 1.4 1.5 1.6 1.6 1.5 1.4 1.2 1.0 0.9 0.8 0.7 0.8 0.9 1.1 1.5 2.0 2.5 2.8 2.8 2.5 2.1 1.7 1.4 1.4 1.6 1.8 1.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.7 0.9 1.0 1.1 1.1 1.1 1.1 1.0 0.9 0.8 0.7 0.6 0.6 0.7 0.8 1.0 1.2 1.5 1.8 2.0 2.0 1.8 1.5 1.3 1.1 1.0 0.9 0.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.5 0.6 0.7 0.8 0.8 0.8 0.8 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.6 0.8 0.9 1.1 1.3 1.4 1.4 1.3 1.1 0.9 0.8 0.7 0.6 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5 0.6 0.6 0.5 0.5 0.5 0.4 0.4 0.4 0.4 0.4 0.5 0.6 0.7 0.8 0.9 0.9 0.9 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.7 0.6 0.6 0.5 0.4 0.3 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.6 2.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.7 2.2 5.0 4.4 1.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.3 0.6 1.2 1.9 1.6 0.7 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.5 0.7 0.6 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICEU:\19110\BIM DWGS\DWGS\19110_SE1.0.dwg | Plotted on 8/12/2020 10:34 AM | by Andrew Rowe11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA43567 #19110 GRAPHIC SCALE:02/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/12/2020COUNTY COMMENTS1" = 20'CALCULATED LIGHTING LEVEL PLAN8/12/20 SE1.0 A. ROWE A. ROWE J. STUTZMAN 1" = 20' &$/&8/$7('/,*+7,1*/(9(/3/$1 6&$/(˛ ˇ ($&+287'225/80,1$,5((48,33(':,7+$/$037+$7(0,7625025(,1,7,$//80(166+$//%($)8//&872)) /80,1$,5($1'6+$//%($55$1*('256+,(/'('725()/(&7/,*+7$:$<)520$'-2,1,1*5(6,'(17,$/',675,&76 $1'$:$<)520$'-$&(1752$'67+(63,//29(52)/,*+7,1*)520/80,1$,5(6217238%/,&52$'6$1'3523(57< ,15(6,'(17,$/25585$/$5($66+$//127(;&(('21(+$/))227&$1'/( 67$1'$5'/,*+7,1*127( /,*+7,1*/(9(/&$/&8/$7,216800$5< $5($6<0%2/81,76$9*0$;0,1 $9*0,1 //) 3$5.,1*/27 IF ˇˇ˛ 1213$5.,1*$5($IF ˇ1$ //) )& $9* 0$; 0,1 7<3 821 $%%5(9,$7,216 /,*+7/266)$&725 )227&$1'/( $9(5$*( 0$;,080 0,1,080 7<3,&$/ 81/(6627+(5:,6(127(' ),;785(02817('$7˙$%29(),1,6+('*5$'( 127(67+,66+((7 )5((67$1',1*32/(02817('/80,1$,5(66+$//%( 02817('72127(;&(('$%29(),1,6+('*5$'( ,1&/8',1*32/(%$6($1'32/( /80,1$,5(02817,1*+(,*+7 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICEU:\19110\BIM DWGS\DWGS\19110_SE5.0.dwg | Plotted on 8/12/2020 10:34 AM | by Andrew Rowe11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA43567 #19110 02/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/12/2020COUNTY COMMENTSN/A FIXTURE DETAILSSE5.0 A. ROWE A. ROWE J. STUTZMAN 8/12/20 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.608 Preston Avenue, Suite 200 | Charlottesville, VA 22903TEL 434.295.5624 FAX 434.295.8317 www.timmons.comTHIS DRAWING PREPARED AT THECHARLOTTESVILLE OFFICEU:\19110\BIM DWGS\DWGS\19110_SE5.1.dwg | Plotted on 8/12/2020 10:34 AM | by Andrew Rowe11/25/2019 BEAVER CREEK - MEDICAL OFFICE BUILDINGALBEMARLE COUNTY, VIRGINIA43567 #19110 02/04/2020COUNTY COMMENTS04/21/2020COUNTY COMMENTS07/31/2020COUNTY COMMENTS08/12/2020COUNTY COMMENTSFIXTURE DETAILSSE5.1 N/A A. ROWE A. ROWE J. STUTZMAN 8/12/20