HomeMy WebLinkAboutSDP202000019 Approval - County 2020-09-21COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902-4596 Phone (434) 296-5832 Fax (434) 972-4126 September 21, 2020 Scott Collins Collins Engineering RE: SDP-2020-019 and SUB2020-033 Pleasant Green Phase 2- Initial Site Plan and Preliminary Plat Mr. Collins: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced initial site plan and preliminary plat. This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final site plan and final plat for all or a portion of the site within one (1) year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 and Section 14-226 of the Code of the County of Albemarle, and thereafter diligently pursues approval of the final site plan and final plat. In accordance with Chapter 18 Section 32.4.2.8 Early or Mass Grading may be permitted after the following approvals are received: 1. Engineering approval of a VSMP plan meeting the requirements of Chapter 17 of the Code of the County of Albemarle. 2. Approval of all easements for facilities for stormwater management and drainage control. 3. Submittal of a tree conservation checklist with areas for tree preservation identified. 4. Applicable conditions from SP2019-002 related to the stream crossing have been completed. The final site plan will not be considered to have been officially submitted until the following items are received: 1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. 2. Applicable fee outlined in the application. The final plat will not be considered to have been officially submitted until the following items are received: 1. A final plat that satisfies all of the requirements of section 14-303 and sections 14-304 through 14-318 of the Code, and the conditions attached to this letter. 2. Applicable fee outlined in the application. Please submit 8 copies of the final plans or electronic plans to the Community Development Department (for ACSA, please submit 3 copies of construction plans directly to them, as stated in their comments). The assigned Lead Reviewer will then distribute the plans to all reviewing agencies. Once you receive the first set of comments on the final site plan, please work with each reviewer individually to satisfy their requirements. The Department of Community Development shall not accept submittal of the final site plan or final plat for signature until tentative approvals for the attached conditions from the following agencies/reviewers have been obtained: SRC Members: Albemarle County Engineering Services (Engineer)- 2 copies Albemarle County Planning Services (Planner)- 3 copies- Megan Nedostup (m nedostu p@a I bema rle.org) Albemarle County Department of Fire Rescue-1 copy- Shawn Maddox (smaddox@albemarle.org) Albemarle County Service Authority- 1 copy Richard Nelson (rnelson@serviceauthority.org) Virginia Department of Transportation- 1 copy —Adam Moore (Adam. Moore@vdot.virginia.gov) Albemarle County Information Services (E911) Albemarle County Building Inspections (Building Official) If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3004, mnedostup@albemarle.org. Sincerely, Megan Nedostup Principal Planner �IRCI, �1\P County of Albemarle Department of Community Development Memorandum To: Scott Collins From: Megan Nedostup- Principal Planner Division: Planning Services Date: April 17, 2020 Updated: September 21, 2020 Subject: SDP2020-019; SUB2020-033 Pleasant Green Phase 2- Initial Site Plan and Preliminary Subdivision Plat The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Requirements for Site Plan and Subdivision: 1 [32.5.2(a); 14 302(B)(5)1 Both the initial site plan and then elirninaFy S bdi.d.inn plat cannet be a .ed unto! the SP u ndeF Feview is appFeved fn. then elsr OR the plans aFe ...d t. Fnatch the existing co that was ed (SP20 6 003 West Glen). The 2. [32.5.2(a); 14-302(B)(5)] The conditions of the SP need to be included on the plans. 3. r r SP canditiensl Per the cenditiens of the special use peRnit, lets density ....lewlatinnIn nl.. 89 W nit. a peFFAine d (see att....hed ... n) 5. 132.5.2(a); 14-302(B)(5)] Not all the parcels are listed or shown. As stated above, the crossing is required for this phase and needs to be included with the plans. Also, the tax map and parcels corresponding to this crossing need to be added to the plans (56-115; 56A1-01-30A; 55C-03-A1). 6. [32.5.2(a); 14-302(B)(8)] On some of the sheets the rear setback is labeled as "front", revise. 7. [32.5.2 (k); 14-302(A)(13)] Stormwater management facilities need to be shown on the plans. 8. [32.5.2(a); 14-302(A)(16)] These properties are within the dam break inundation zone, this should be shown on the plans. Site Plan Requirements: 1. See attached direction from the Post Master regarding group mailboxes. Please coordinate location with the Post Master. 2. [32.5.2(b); 32.5.2 (n)] A chart should be provided to outline the recreation and amenities. This should include what is required for each phase and what is being provided and where and the application numbers under which they were approved. In addition, if substitutions of the requirements are needed, a request should be made for consideration of the Planning Director. 3. [32.5.2(b)] If the parking space along McComb will be removed for Phase 3, a plan for how the parking requirements will be met for this phase should be considered. 4. [32.5.2(c)] It is unclear which phase the area north of McComb will be developed under with the current phase lines. Please clarify. Will this be a part of Phase 3, or will this be open space for this phase? 5. [32.5.2 (e)] Sheet 6 does not include the utilities to determine whether or not there are conflicts with the street trees. Also, some of the trees are not in the right of way, even when there are not conflicts. A full review of the landscape requirements will be completed during the final site plan. 6. [32.5.2 (n)] The cover sheet mentions a trail being provided; however, it is not shown on the plans. The trail, including its material, type, dimensions, and if it will be dedicated to the county or a public easement should be shown on the plans. Subdivision Requirements: 1. [14-302(A)(3)] Provide the width, names and right of way of all existing and platted streets (Cling Lane, and label the stated width as proposed right of ways). 2. [14-302 (A)(4)(5)] Show the location and dimension for all easements for all utilities, trails, etc. 3. [14-302(A)(8)] Show how the existing lot lines will be modified. Will they be removed? Land hooks showing a boundary line adjustment are needed. The existing conditions sheet needs to clarify the lot lines and the phase lines. 4. [14-302(A)(14)] Indicate the land that will be dedicated to public use or reserved for common use of the owners in the subdivision, such as trails and open space. Please contact Megan Nedostup at the Department of Community Development mnedostuoCcDalbemarle.ore for further information. Review Comments for SDP202000019 Initial Site Plan Project Name: Pleasant Green - Phase 2 - Initial Date Completed: Sunday, April 05, 2020 Department/Division/Agency: Review Status: Reviewer: Michael Dellinger CDD Insoections Requested Changes Add the following note to the general notes page: ALL water lines, sewer lines, and fire lines from the main to the structure MUST have a visual inspection performed by the building department. Add the following note to the general notes page: Where the flood level rims of plumbing fixtures are below the elevation of the manhole cover of the next upstream manhole in the public sewer, the fixtures shall be protected by a backwater valve installed in the building drain, branch of the building drain or horizontal branch serving such fixtures. Plumbing fixtures having flood level rims above the elevation of the manhole cover of the next upstream manhole in the public sewer shall not discharge through a backwater valve. Note to developer: Due to required distances from lot lines and structures as required by the NFPA, underground propane tanks may be prohibited. Plan accordingly. Review Comments for SDP202000019 I Initial Site Plan Project Name: Pleasant Green - Phase 2 - Initial Date Completed: Friday, March 27, 2020 Department/Division/Agency: Review Status: Reviewer: Brian Becker CDD E911 Requested Changes Critical Issues: McComb Street connects to the end of Cline Drive and will need to change names at an intersection. The most appropriate intersection for the name change is at Lexi Lane. Please label the road currently lableled McComb St. as McComb St. east of Lexi Lane and Cline Drive west of Lexi Lane. (Z) COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION Stephen C. Brich, P.E. 1401 East Broad Street (804) 786-2701 Commissioner Richmond, Virginia 23219 Fax: (804) 786,2940 April 15, 2020 County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Attn: Megan Nedostup Re: Pleasant Green — Phase 2 SDP-2020-00019 SUB-2020-00033 Review #1 Dear Ms. Nedostup: The Department of Transportation, Charlottesville Residency Transportation and Land Use Section, has reviewed the above referenced plan as submitted by Collins Engineering, dated 24 February 2020, and offers the following comments: 1. TTE trip generation was not verified at this time. 2. Please show parking bump -outs on McComb Street per AASHTO Green Book 2011— 4.20 On -Street Parking. 3. Sidewalks adjacent to curb will be 8' in width per RDM B(1)-31. 4. Please remove trees within 30 of intersections per B(1)-44 RDM. 5. Landscaping plants and trees adjacent to the sight distance triangle will need to be maintained in area between 2 and 7 feet above ground as a clear zone to preserve sight lines and accommodate pedestrians. 6. Approved road plans meeting SSAR, and in compliance with the VDOT Road Design Manual are required prior to plat approval. 7. Please show mill and overlay on plans in accordance with WP-2. Show limits of mill and overlay to adjacent travel lane. Also, please add the WP-2 detail to the plans. 8. Please provide an MOT plan in accordance with the Virginia Work Area Protection Manual. MOT plan should be on a separate sheet and designed for this project, include the proposed mill and overlay areas. 9. Please show "No Parking" sign locations. VirginiaDOT.org WE KEEP VIRGINIA MOVING 10. CG-12 at intersection of Alston Road and Litchford Street is miss -labeled as CG-913. 11. All CG-12's should be shown and shaded in place. 12. Please label radii for both entrances into Phase 3 and proposed entrance detail. 13. Please show sight distance lengths onto McComb Street from both Lexi Lane and Dunnagan Drive. 14. Please show and label driveway access through proposed right-of-way. CG-9D is recommended see RDM B(1) pages 28 to 30. 15. Please check CG-6 for parking space near proposed lot 76. 16. Please note Appendix B(1)-22 requires a minimum intersection spacing of 200' and this distance shall be adjusted upward based on upstream and downstream intersection turning movement volumes. 17. Note that the final site and subdivision (road) plans must show conformance with the VDOT Road Design Manual Appendices B(1) and F, as well as any other applicable standards, regulations or other requirements. 18. Due to the level of items noted in this review, these comments may not be exhaustive. 19. Please provide a comment response letter with each submission after the initial. Please provide a copy of the revised plan along with a comment response letter. If further information is desired, please contact Max Greene at 434-422-9894. A VDOT Land Use Permit will be required prior to any work within the right-of-way. The owner/developer must contact the Charlottesville Residency Transportation and Land Use Section at (434) 422-9399 for information pertaining to this process. Sincerely, Adam J. Moore, P.E. Area Land Use Engineer Charlottesville Residency Review Comments for SDP202000019 Initial Site Plan Project Name: Pleasant Green - Phase 2 - Initial Date Completed: Monday, March 30, 2020 Department/Division/Agency: Review Status: Reviewer: Shawn Maddox Fire Resc I No Objection A current fire flow test is required before final acceptance. Fire Rescue has no objections. SNM � AI ?"h �IRGRTF County of Albemarle Department of Community Development Memorandum To: Megan Nedostup From: Emily Cox Date: 20 April 2020 Subject: Pleasant Green Phase 2 - ISP (SDP202000019) The initial site plan for Pleasant Green Phase 2 has been reviewed by Engineering. The following comments will need to be addressed before approval: 1. WPO Plan must be approved before final site plan can be approved. 2. Road Plan must be submitted and approved before final site plan can be approved. Please remove applicable road plan sheets from final site plan. 3. Professional seal should be signed and dated. 4. Per County Code 17-601-C, each stream buffer shall be incorporated into the design of the development by keeping stream buffers in open or natural spaces, and out of residential lots or areas of active use, to the fullest extent possible. Please remove lots from the WPO buffer. 5. What is the layout for Phase III? Will this change any requirements, for example, will the alley need to be public? 6. Provide more contour labels. It is difficult to follow the grading. 7. Slopes steeper than 2:1 are not allowed. Slopes steeper than 3:1 must have something specified to grow that can handle the slopes. 8. Sight distance lines cannot go through parking spaces. � AI ?"h �IRGRTF County of Albemarle Department of Community Development Memorandum To: Megan Nedostup From: Emily Cox Date: 20 April 2020 Subject: Pleasant Green Phase 2 - PP (SUB202000033) The Preliminary Plat for Pleasant Green Phase 2 has been reviewed by Engineering. The following comments will need to be addressed before approval: 1. WPO Plan must be submitted and approved before final plat can be approved. 2. Road Plan must be submitted and approved before final plat can be approved. 3. Professional seal should be signed and dated. 4. Per County Code 17-601-C, each stream buffer shall be incorporated into the design of the development by keeping stream buffers in open or natural spaces, and out of residential lots or areas of active use, to the fullest extent possible. Please remove lots from the WPO buffer. Megan Nedostup From: Dyon Vega <DVega@rivanna.org> Sent: Tuesday, April 21, 2020 3:12 PM To: Megan Nedostup Cc: vfort@rivanna.org; Richard Nelson Subject: Pleasant Green Phase 2 comments CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Megan, RWSA has reviewed the Pleasant Green Phase 2 Initial site plans dated February 241h 2020 and has the following comments. General comments: RWSA will require a sewer flow acceptance prior to final site plan approval. The request will need to be sent to us by ACSA and will include the following: • Estimated average daily dry weather sewage flow (ADDWF) • Point of connection into RWSA system (which manhole) • Number of units/square footage • Estimated in-service date Sheet 4: 1. Lots 153 and 154 call out a patio and deck which would encroach on the RWSA easement, please make sure this is not within the easement. Sheet 7: 1. Show and label the RWSA waterline easement. Include deed book and page number. 2. Please provide a footer and deck/patio design for lots 153-154. RWSA does not allow footers or any other structures in the easement (see comment below). 3. Overhangs, footers, or subterranean structures are not allowed in the RWSA easement. These could interfere with access to our waterline, please make a note of this for lots 153-154. 4. RWSA is evaluating its needs for an easement to access the waterline located behind lots 143-154. One possible option for an access easement is between lots 148 and 149. RWSA will work to finalize this request and asks that any requested easements be included in the final site plan. Sheet 11: 1. No trees are allowed in RWSA easement. Let me know if you have any questions. Dyon Vega Civil Engineer Megan Nedostup From: Richard Nelson <rnelson@serviceauthority.org> Sent: Tuesday, April 21, 2020 3:19 PM To: Megan Nedostup Subject: RE: Pleasant Green (SDP2020-019 and SUB2020-033) CAUTION: This message originated outside the County of Albemarle email system. DO NOT CLICK on links or open attachments unless you are sure the content is safe. Megan, I recommend Pleasant Green (SDP2020-019 and SUB2020-033) for approval with the following conditions: Submit a PDF copy of the plan set and water/sewer data sheets to ACSA, attn: Richard Nelson, for review. RWSA sewer capacity certification will be required. RWSA approval of the Final Site Plan will be required prior to ACSA approval. Thanks, Richard Nelson Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (434)977-4511 From: Megan Nedostup <mnedostup@albemarle.org> Sent: Tuesday, April 21, 2020 3:16 PM To: Richard Nelson <rnelson@serviceauthority.org> Subject: Pleasant Green (SDP2020-019 and SUB2020-033) Hey Richard, Wondering if you had comments for the Pleasant Green submittals? Thanks, Megan Nedostup, AICP (pronounced nuh-DAHST-up) she/her/hers (What is this?) Principal Planner Community Development Department Planning Services ph: 434.296.5832 ext. 3004 MANAGER, OPERATIONS PROGRAM SUPPORT UNITED STATES POSTAL SERVICE POUNITEDSTATES T POSTAL SERVICE Date: November 23,2015 Subject: New Developments In April 2012, the USPS revised regulation to clarify options for delivery and to provide the USPS greater autonomy in determining how deliveries are added to the Postal Service network. While curbline and sidewalk delivery remain viable and approved modes of delivery, the USPS will determine how and when to approve these modes of delivery consistent with existing Postal Operations Manual (POM) regulation regarding in -growth and both establishment and extension of delivery. Each year, new delivery addresses are added to our city, rual and contract routes which has a major impact to our delivery cost. To control costs, we need to ensure new residential deliveries are being made via centralized delivery. We must adhere to the guidelines that govern establishment of new delivery. The City/County authorities (Planning and Zoning) can not give approval of delivery service. The Postal Service cannot honor agreements that have been made between Planning and Zoning and the developer. At a minimum, the USPS will work with the builders and developers to determine what the best mode of delivery is for the area prior to establishing or extending delivery service. However, as a national agency, the USPS reserves the right to establish delivery in the most consistent and cost effective means viable to meet our federal mandate of providing a free form of service that best meets the need to establish and maintain a safe, reliable and efficient national Postal Service. Please review the changes to the POM regarding Modes of Delivery and Delivery Equipment. The changes are designed to enhance our ability to increase centralized and CBU delivery. • Centralized and CBU delivery is now the default mode of delivery in business areas. Any exceptions to centralized or CBU delivery mode in business areas must be approved by the District. (631.2) For new residential delivery, CBU is now the default. Exceptions to permit curbline delivery must be approved by the District. (631.32) • New deliveries within an existing block with an established mode of delivery no longer assume the existing mode of delivery. We can require a more efficient mode of delivery (sidewalk delivery, for example). (631.41) • While we do not control addresses for buildings, we do control the sequential ordering of addresses within any centralized delivery equipment. (631.442) If more than one building in a complex has the same street address, the delivery equipment must be grouped at a single location even if some of the units are in a different building. (631.452) • Centralized delivery or CBU is the default option for delivery in mobile homes or trailer parks that are permanent residences. Any exceptions to centralized or CBU delivery mode must be approved by the District (631.462b) • For dormitories and residence halls not directly affiliated with colleges, the Postal Service determines the mode of delivery and can require the property owner to accept mail for all the tenants. We will not distribute mail into centralized delivery equipment. (631.52) • Delivery equipment must conform with the USPS standards for CBUs and high-rise delivery equipment, USPS STD 4C wall mounted mail receptacles. Local offices do not have the authority to approve any other centralized delivery equipment. (631.441) -2- • When obsolete delivery equipment is replaced in multi -unit buildings, it must be replaced with equipment that meets current standards. (632.621) The USPS standards include options for parcel lockers that we should ensure are provided. There was also great consideration regarding safety of delivery, which also resulted in the determination the the type of delivery warrented in your area. Keith Smarte Crozet Postmaster 1210 Crozet Virginia 22932 Work 434-823-9847 Cell434-529-0241 Keith.A. Sm a rteO usps.aov