HomeMy WebLinkAboutZMA202000010 Review Comments Zoning Map Amendment 2020-10-02County of Albemarle
Department of Community Development
October 2, 2020
Tim Miller
Meridian
440 Premier Circle, Suite 200
Charlottesville, VA 22901
RE: Review Comment Letter #1: ZMA202000010 Arbor Oaks Townes
Mr. Miller,
Staff has reviewed your submittal for a zoning map amendment (ZMA) for Arbor Oaks Townes.
We have a number of questions and comments which we believe should be addressed before
we can recommend favorably on your ZMA request. We would be glad to meet with you to
discuss these issues. Our comments are provided below:
Zoning Map Amendment Comments
Planning Comments: Rezoning (Tori Kanellopoulos vkanellopoulos(aD-albemarle.org)
1. The application narrative states that no proffers are proposed as part of the rezoning.
Since the rezoning is not for a Planned District, anything shown on the submitted plan
will not be a proffered commitment without a written proffer statement. This means that
the improvements and project layout shown on the current layout plan will not be a
proffered design of the neighborhood. This also means that there has not been a
commitment to density or a specific unit count or range. If a proffered Conceptual Plan is
provided, the proffer statement should refer to the Plan and list the major elements.
a. If the Conceptual Plan is proffered, note that the level of detail currently shown
may not be appropriate for a rezoning. For example, specific square footages for
lot sizes are shown, however this does not allow for flexibility during site
planning. A Block Plan would be more appropriate, while still showing that site
requirements (e.g. landscaping) can fit within the site.
b. If changed to a Conceptual Plan, title "ZMA202000011 Conceptual Plan".
2. The Comprehensive Plan (Housing Chapter, Strategy 6b) recommends that a minimum
of 15 percent affordable housing units be provided in developments subject to rezoning
approvals. During the preapplication meeting, the applicant proposed affordable units for
an affordable housing density bonus. However, this application does not appear to
propose any affordable units.
3. Revisions are needed to the frontage area along Hydraulic Road to address
Transportation Planning, ARB, and Planning comments. A planting strip is needed
between the street and the sidewalk to provide a buffer. Additional information is needed
to show ARB street tree requirements can be met.
a. The Places29 Master Plan also calls for street trees and landscaping along this
frontage — see Comprehensive Plan/Master Plan comments in the following
section. The landscaped residential yard frontage treatment recommended by
the Master Plan has not been addressed.
b. Street sections should be provided.
4. Provide an updated project narrative stating the potential impacts to schools, public
utilities, streets, and fire service.
5. Include the Comprehensive Plan designation of the property on Sheet 1
6. Remove reference to 'minimum lot area proposed'. A minimum lot for R-15 cluster
cannot be established.
7. More information is needed for the R-15 cluster development request:
a. Include the open space calculation for the development. Per cluster development
regulations (18-2.2.3), at least 25% of the site must be in common open space.
b. Provide additional information on the proposed amenities for the open and
recreation spaces.
c. Part of the open space is adjacent to Hydraulic Road. Would any buffering (e.g.
landscaping or fencing) be provided here, to create a safer and more pleasant
space?
d. Consider how residents will access the open space. Consider providing paths
internally to the site for access, instead of residents needing to walk along
Hydraulic Road to access the open space.
8. Provide building height requirements and stepback requirements proposed for this
rezoning on Sheet 1. Note that the R-15 zoning district allows up to 65 feet in height,
however the Places29 Master Plan recommends up to 4 stories or 45 feet in Urban
Density Residential designations. If a Conceptual Plan is provided, a height should be
specified. If no Conceptual Plan is proposed, then the height requirement will be the
standard R-15 requirement.
9. Revise setbacks notes on Sheet 1 per Zoning comments (non-infill residential setbacks).
10. See additional comments/details provided with Neighborhood Model Principles section
below. Note that the narrative did not specifically address these principles.
11. A community meeting is scheduled for Monday, October 19 from 5:30 — 7 PM with the
Places29 Hydraulic CAC. Note that additional considerations and concerns from
residents may be brought up during the meeting. The Planning Commission and Board
of Supervisors will consider input from community members.
12. Note the following requirements that will be needed during site planning. This may not
be a complete list, however given the size of the site, it is important to consider how
these requirements will be met:
a. Note that development of townhouses would require an initial and final site plan,
a preliminary and final plat, a road plan, and a VSMP/WPO, meeting all local and
state requirements, including County Code Chapters 14, 17, and 32.
b. Parking areas of at least five (5) spaces must have at least five (5) percent of the
parking area landscaped. Additionally, one (1) tree is needed for every 10
spaces.
c. The parking area will need to be screened from adjacent residential districts.
d. Street trees will be required.
e. The minimum tree canopy for the site will be 15 percent.
f. Recommend lots be revised so that lot lines are not within the proposed private
street. There is no minimum lot size for R-15 cluster developments.
g. The proposed private access easement will need to be a 'private street
easement'. Additionally, the easement seems to be adjacent to the proposed
townhouses. The easement should only extend to the edge of the parking areas
(or to the edge of the sidewalk). Setbacks are measured from the sidewalk or the
street right of way.
Private Street Request
Per 14-233(B)(1), the agent may authorize one (1) or more new private streets in the
Development Areas when the subdivision will contain attached residential units where units are
to be located on individual lots.
In accordance with 14-234(C), the agent may authorize one (1) more private streets if it finds
that:
1. The private street will be adequate to carry the traffic volume which may be reasonably
expected to be generated by the subdivision;
Engineering has no objection to the private street request. The amount of traffic
expected on the requested private street for this development is minimal. Note that the
proposed parking design could cause a safety hazard if there was a future connection to
the adjacent parcel to the east.
2. The comprehensive plan does not provide for a public street in the approximate location
of the proposed private street;
The Places29 Master Plan (in the Comprehensive Plan) does not provide for a public
street in this location.
3. The fee of the private street will be owned by the owner of each lot abutting the right-of-
way thereof or by an association composed of the owners of all lots in the subdivision,
subject in either case to any easement for the benefit of all lots served by the street;
The applicant has included information with the private street request that the private
street would be owned and maintained by an HOA. A private street easement and
private street maintenance agreement meeting 14-317 will be required during site
planning.
4. Except where required by the commission to serve a specific public purpose, the private
street will not serve through traffic nor intersect the state highway system in more than
one location; and
The street would only intersect with Hydraulic Road in one location. It is unclear if there
is a stubout for a potential future connection to the adjacent parcel to the east. Is a
retaining wall necessary in this location, or is there still potential for a future connection
between the two parcels? Note that per 14-234(B)(ii), a private street "should not serve
as the primary or sole interconnection between the subdivision and abutting property'.
However, it is not clear if the adjacent parcel has other reasonable means of access to
Hydraulic Road that would meet VDOT standards. Additional information is needed for
review.
5. If applicable, the private street has been approved in accordance with section 30.3, flood
hazard overlay district, of the zoning ordinance and other applicable law.
The parcel is not located within the flood hazard overlay district.
Special Exception Request (Planting Strip Waiver)
The required planting strip may be waived by the Planning Commission per 14-422(F). Staff
provides a recommendation to the Commission on this request. The recommendation will be
provided with the staff report.
In reviewing a request to vary or except any requirement for planting strips, the Commission
shall consider whether:
(i) a variation or exception to allow a rural cross-section has been granted;
A waiver to allow a rural cross-section has not been granted or requested and is not
necessary for this development.
(ii) a sidewalk variation or exception has been granted;
A sidewalk variation or exception has not been requested.
(iii) reducing the size of or eliminating the planting strip promotes the goals of the
comprehensive plan, the neighborhood model, and the applicable neighborhood
master plan; and
It could be challenging to develop this small site at the recommended density in the
Comprehensive Plan and with sufficient open space with a full street including
curb/gutter, sidewalk, and planting strip. It may be appropriate to not have street
trees in this location. However, other landscaping and street trees should be
provided in other areas of the site, and more information should be provided on how
the site planning and ARB landscape requirements will be met.
(iv) waiving the requirement would enable a different principle of the neighborhood
model to be more fully achieved.
Additional information should be provided to address the Neighborhood Model
Principles comments in this letter.
Zoning (Kevin McCollum kmccollum0albemarle.org)
1. The applicable setbacks for the property are as provided in Section 4.19. The
development will be considered "non-infill."
a) Front — 5'
b) Side — 5'
c) Rear — 20'
2. Since they are doing a cluster development Section 2.2 requires that 25% of the land
area be open space subject to Section 4.7. It appears they are meeting these
requirements; however, I have a couple questions. Who will own the open space? Is the
open space on the north side of the property accessible? Will this be open space the
residents and/or the public can use?
3. The minimum parking requirements of 28 spaces (2 per dwelling unit) is correct, but I
have some concerns about this.
a) Typically, townhouse developments will provide some number of guest parking
spaces — such as 1 per 4 spaces.
b) There are two ADA spaces being proposed. These two are counted towards the
requirement on the plan, but what happens if no one in the community requires
an accessible space? This would imply they are 2 parking spaces short. From an
accessibility standpoint providing accessible spaces seems like a good thing, but
I think they should be in addition to all 28 required spaces.
c) 4.12.15(i) implies that if accessible spaces are provided, they should provide the
shortest practical route and should not cross vehicular access ways. If accessible
parking were proposed on the South side of the street, I think it would only make
sense if there were accessible parking spaces on the North side of the street as
well. If they are adamant about providing only two accessible spaces, they could
provide 1 on one side and the other on the other side of the street.
4. 1 have no objections to the exception request for the planting strip requirement.
Engineering (Frank Pohl fpohl(&albemarle.org)
1. No objection.
VDOT (Adam Moore adam.moore(&ydot.virginia.gov)
1. See attached letter dated 09-24-20.
Albemarle County Service Authority (Richard Nelson rnelson(&_serviceauthoritv.org)
1. See attached letter.
RWSA (Dyon Vega dvega(&rivanna.ora)
RWSA has reviewed application ZMA2020-10 lb&0 Arbor oaks. Below is a completed copy of the form that was provided to us by Elaine
Echols for SP & ZMA Applications.
To be fitted out by RWSA for ZMA's and SP's
1. Capacity issues for sewer that may affect this proposal Non. Known
2. Requires Rivanna Water and Sewer Authority Capacity Certlficabon Yes x- No
3 Water now or pressure issues that may affect this proposal None Known
4. "Red flags" regarding service provision (use attachments it s-: ,, 'Ion. Known
Let me know if you have any questions. RWSA has no conflict.
Transportation Planning (Kevin McDermott kmcdermott0albemarle.org)
1. The existing sidewalk along Hydraulic Rd does not meet minimum standard. This should
be removed and reconstructed with a minimum buffer strip of 4' and a minimum 5'
sidewalk behind that are all contained within dedicated right-of-way.
Fire/Rescue (Shawn Maddox smaddox(a)albemarle.org)
1. There does not appear to be an emergency apparatus turn around on the site. The travel
way appears to exceed 150' in length.
2. The fire hydrant should be placed at the entrance to the development.
Architectural Review Board (Margaret Maliszewski mmaliszewski(a'albemarle.orci
1. Show on the plan how Entrance Corridor frontage planting requirements can be met
(large shade trees 35' on center and interspersed ornamentals) while accommodating
sidewalk and sight distance requirements and avoiding conflicts with utilities and utility
easements.
2. Add the planting area and relocated utility easement to the plan.
CDD E911 (Brian Becker bbecker(&albemarle.org)
1. No objection.
Building Inspections (Michael Dellinger mdellinger0albemarle.oro)
1. Add the following note to the general notes page: Retaining walls greater than 3 feet in
height require a separate building permit. Walls exceeding 4 feet in height require a
stamped engineered design also. Walls require inspections as outlined in the USBC.
Wall will also require a maintenance agreement.
2. Add the following note to the general notes page: Where the flood level rims of plumbing
fixtures are below the elevation of the manhole cover of the next upstream manhole in
the public sewer, the fixtures shall be protected by a backwater valve installed in the
building drain, branch of the building drain or horizontal branch serving such fixtures.
Plumbing fixtures having flood level rims above the elevation of the manhole cover of the
next upstream manhole in the public sewer shall not discharge through a backwater
valve.
3. Note to developer: Due to required distances from lot lines and structures as required by
the NFPA, underground propane tanks may be prohibited. Plan accordingly.
Comprehensive Plan
Comments on how your project conforms to the Comprehensive Plan will be provided to the
Planning Commission and Board of Supervisors as part of the staff report that will be prepared
for the public hearing. Initial comments are provided with this comment letter.
The proposed development is designated Urban Density Residential in the Places29 Master
Plan. The intent of this designation is to provide residential uses between 6 and 34 units/acre,
with some non-residential uses permitted as secondary uses. Residential uses should be a
maximum height of 4 stories or 45 feet. Open space should be usable for residents.
L
.a
Wr PW. y
D—o""9 o
e!eelri�raewbned0rYwUr.]s.
eWwWndevrnY
abII.IrreOewItrr
URa•mrwMek
b.lP
ennl0utlILw.e
OW." a 01 - 34
Iba
FVl
NgM4M.P.!
Mry•.rr.
miaulrmIa
WM•
Nam
act
•ll
.
NOW&C'N,oci"w
• A.-Wylrlrn
IN. d"nonvl
ftmowrrlaw
CaeRewq&Regrow
• TMM.A
e��abalhba
IM•r•r.
amxra}e b aleeba
PAW
CaRwa aby ha bcaYd
la. rb.e CMIIr.
OCIIrb CalwbrcW
IM eaaWal
Wi1M
aa1'aaaaaa
9Ygr YaiYM r W
OYOOff
T•� aac ur•. b/
.oar•
• a�rrrrw
Wlr
rraael
• rrrr,gr
Mrb CenwlrCbl Pelee
sm�
i $91NI e
SeiO••ISMaarW
4el the
•HM.rnr.w.
rIr]rs rrrb
Net eanlllae
•w.aww
w.�r...err
rrrar..
• I.rrs
trot
rrr
eaMra.sr
lo..r
• �Saaw]•
CIRCe
• TIbYlIIM1e
AMMCIIi
.®aePebbrreb
rrw.a•ss�
OenMe/ebN
Caeae slay C. baaM
.r
tR��p
In Ne�rbr Cube
rM..Yw Y.M
N.ar—
Stly YSYarW
IFyeawpllm
•yrllrrer•Iy
Mn..bw. Psr b
.Wr.
rwer�rswwe
Wr enall•ww
n19n
V.M VPfe"eebvavoer. 1nIi a[frpernvo raIoc. m.... l lT. x. rbnllramnY
r houang xnh , ara.. dcri" r& b.weer 6.OI vad 74 urib M acre a d tc d. II b.Ilo.pphed
School
to evebng razntrnbd acas wiUl drunks x]Ihrn thn rmlge lsee Lad V.r Tabk LU'_I Tbu
1�- -
do oyxo ...s ezumiolly IN, sane m the VIbI. Ikra r Reudemul Jrnpulnn m the 1996 Lad
I I
Use plm.
1-,, u,: ".1t4c ly.bl Nagle-lawk mdrnnnL , dIwa g Mv'. Mw kuvmg
1
IYpa.
Secmd m ese.: mail, mwmadd. ad off ice use char s.pp.al the rc.ghbaNaJ,
bmwork wU, inar".rmal RemlI.
apen space. ad u.es cmwttciul. alfcc, and
inow wi aal ware maweprd b locaa m I calm w they arc acnc.•.hk" reddens
ihrwldvan th, swc. unJwy area, end w dlcy t.enetit fnlm rnkwon.n wn! .nha
1\� 3°
--
ncigflM.rhlad-.c].Ing Mnlrtcur.. IlaxrssT. thry any Ir 6w 1 by culTgn.n nI in ca.
x_
.nmld ('cram design acd 1. rhun rlca•ay Re oknunl pmcded they arc ro jai( ihk w nh
Legend
Forested Buffer
Open Landscape
Landscaped Development
Landscaped Residential Yard
Urban Frontage
Landscaped Residential Yard Frontage
Landscaped Residential Yard is the reaxnnrrndA truntage condition for wgmrnts of rntranee
Corridors where existing and future midential yards face a strect. Along US -19. residential
yards arc not expected to face the street. For all other Entrance Comdors in the Placcs29 area, the
intent of this designation is to recognirc the need for separation between residential properties.
both single and multifamily residences. and the street. Properties with landscaped frontages
facing the Entrance C orridox should allow for nsidennal buildings, or portions of these buildings.
to be visible from the street and adjacent sidewalks (see Figures 7.13 and 7.14). This will provide
travelers along the Entrance Corridor with a sense of the street's residential character
In a Landscaped Residential Yard Frontage, street trees are expected in the right -of --wan between
the sidewalk and JK street. Street Imcs introduce vertical elements that help create a sense of
enllusure along Entrance Corridors. This is important as Entrance Coriiduts lend to be widen than
mast other sireviv and can easily lose Ibe• desimJ sense of enclosure. The landscaped area between
the sidewalk and the building front should have sufficient depth to wperate the private residential
space from the pobhc space of the sidewalk.
In areas designated Landscaped Residential Yard, the height of street -facing hedges or fences
should not exceed four (4) feet. Such a low height allows pedestrians and drivers to have a sense
of the residential mturc of the area.
Neighborhood Model Principles
Projects located within the Development Areas are reviewed for consistency with each of the
Neighborhood Model Principles found in the Comprehensive Plan. Comments are provided
below on relevant aspects of the Neighborhood Model. Revised comments may be given after
additional information is submitted.
Pedestrian Orientation
This principle is partially met. Sidewalks are provided
within the development and connect to existing sidewalks
along Hydraulic Road. Additional information should be
provided for how residents can access the site's open space
without needing to walk along Hydraulic Road, such as
through internal pathways. Revisions are needed to the
existing sidewalk along Hydraulic Road to address
Transportation Planning and Planning review comments. A
buffer is needed between the sidewalk and the road.
Mixture of Uses
This principle is met. This site is less than one acre, is
directly adjacent to other residential development, and is not
located within a Center. It is located within walking distance
of non-residential development and parks/green systems.
Neighborhood Centers
This principle is met. The development is not located within a
Center. It is within walking distance of a Neighborhood
Service Center, Albemarle H.S., and Charlotte Humphris
Park.
Mixture of Housing Types
This principle is partially met. Given the variety of housing
and Affordability
types in the immediate area and the size of this site, staff
finds it consistent with the Neighborhood Model Principles to
provide one housing type on this site. However, the proposal
does not meet Strategy 6b in the Housing Chapter of the
Comprehensive Plan.
Relegated Parking
This principle is partially met. Parking is relegated from
Hydraulic Road. However, parking is not relegated from
dwelling units.
Interconnected Streets and
This principle is partially met. Pedestrian connectivity is
Transportation Network
provided, although revisions to pedestrian connectivity along
Hydraulic Road are needed. No future connection is shown
with the property to the east. If this property were to
redevelop in the future, it may need access through this site
(as spacing requirements may not allow for a second
adjacent entrance).
Multimodal Transportation
This principle is met. The development connects to existing
Opportunities
sidewalks along Hydraulic Road. The development is located
approximately 500 feet from a bus stop for the Route 5 bus
route.
Parks, Recreational
This principle is partially met. Additional information must
be provided to ensure the 25 percent open space
Amenities, and Open Space
requirement for cluster developments is being met. Additional
information should be provided for pedestrian connectivity to
open space through the site. There is also limited information
on what types of amenities or usable open space would be
provided for residents. Consider landscaping and buffering
along Hydraulic Road.
Buildings and Spaces of
This principle is partially met. Consider landscaping and
ARB requirements along Hydraulic Road. Additionally, the
Human Scale
Places29 Master Plan recommends a maximum height of 45'
or 4 stories for residential uses while R-15 allows up to 65'.
Redevelopment
This principle is met. The proposed development is within an
underutilized site within the development areas. The
proposed residential units appear compatible with existing
nearby and adjacent residential development.
Respecting Terrain and
This principle is met. There are no environmental features or
Careful Grading and
significant slopes on this site.
Regrading of Terrain
Clear Boundaries between
This principle is met. The development is located across
the Development Areas and
Hydraulic Road from the Rural Area. The Places29 Master
the Rural Area
Plan does not have any boundary recommendations for this
location.
Action after Receipt of Comments
Staff will work with you to choose a Planning Commission date for public hearing.
Resubmittal
If you choose to resubmit, please use the attached form. There is no fee for the first
resubmittal. The resubmittal date schedule and other related resources are provided for your
convenience online at https://www.albemarle.org/home/showdocument?id=358
Notification and Advertisement Fees
Additional notification fees will not be required unless a deferral takes place and adjoining
owners need to be notified of a new date.
Community Meeting
Prior to requesting a public hearing with the Planning Commission and Board, a community
meeting must be held in accordance with Zoning Ordinance Section 18-33.37. Due to current
circumstances surrounding the COVID-19 pandemic, community meetings are being held
virtually. This application has been scheduled for a community for Monday, October 19, from
5:30 PM — 7:30 PM with the Places29 Hydraulic CAC.
Feel free to contact me if you wish to meet or need additional information. My email address is
vkanell000ulos(a-)albemarle.oro
Sincerely,
Tori Kanellopoulos
Senior Planner
Community Development
434-296-5832 ext. 3270
vkanellopoulos@albemarle.org
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
Stephen C. Brich, P.E. 1401 East Broad Street
Commissioner Richmond, Virginia 23219
September 24, 2020
Tori Kanellopoulos
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Re: ZMA-2020-00010 — Arbor Oaks Townes
Dear Ms. Kanellopoulos:
(804) 7862701
Fax: (804) 7862940
The Department of Transportation, Charlottesville Residency Transportation and Land Use
Section, has reviewed the above referenced, as submitted by Meridian Planning Group, LLC, dated
August 17, 2020 and offer the following comments.
Land use
1. Please provide trip generation data.
2. Please provide right turn lane and taper analysis.
3. Sidewalk will need 411., buffer strip along hydraulic road.
A VDOT Land Use Permit will be required prior to any work within the right of way. The
owner/developer must contact the Charlottesville Residency land Use Section at (434) 422-9399
for information pertaining to this process.
If you have Rather questions please contact Willis Bedsaul at (434) 422-9866
Sincerely,
Adam J. Moore, P.E.
Area Land Use Engineer
Charlottesville Residency
VirginiaDOT.org
WE KEEP VIRGINIA MOVING
ALBEMARLE COUNTY COMMUNITY DEVELOPMENT— Information from Service Providers
To be filled out by ACSA for ZMA's and SP's
1) Is this site in the jurisdictional area for water and/or sewer? Yes
2) What is the distance to the closest water and sewer line, if in the jurisdictional area? On site.
3) Are there water pressure issues which may affect the proposed use as shown on plan? Water
pressures are between 60-75 psi.
4) Are there major upgrades needed to the water distribution or sewer collection system of which the
applicant and staff should be aware?
5) Are there other service provision issues such as the need for grinder pumps? Grinder pumps maybe
needed. Applicant's engineer to confirm.
6) Which issues should be resolved at the SP/ZMA stage and which issues can be resolved at the site
plan/plat stage?
7) If the project is a large water user, what long term impacts or implications do you forsee?
8) Additional comments? RWSA will need to approve the water main connection to their existing 12"
water main along Hydraulic. Things to consider during site plan review; Is it possible to tie into EX
MH-B with the wall outside the ACSA sewer easement. Permeable pavers are not permitted in ACSA
easements. Water will most likely need to come from Olde Oak Ct if RWSA does not approve water
main connection. Existing water meter on site will need to be abandoned.