Loading...
HomeMy WebLinkAboutARB202000104 Plan - Submittal (First) Initial Site Plan 2020-10-05TH SITE DATA: TAX MAP PARCEL AND OWNER INFO: PARCEL(S) 58A2-14 AND 58A2-20 LENVIC LLC 2506 BRANDERMILLPL CHARLOTTESVILLE, VA 22911 TOTAL PARCEL AREA: 0.87 ACRES (PARCELS 58A2-14 AND 58A2-20 COMBINED) LIMITS OF DISTURBANCE: 0.61 ACRES ZONING: C-1 (COMMERCIAL); ENTRANCE CORRIDOR OVERLAY DISTRICT MAGISTERIAL DISTRICT: SAMUEL MILLER SOURCE OF SURVEY, BOUNDARY, AND TOPOGRAPHY: BASED ON FIELD SURVEY BY TIMMONS GROUP DATED 1/11/19. VERTICAL DATUM REFERENCE: NAVD 88 UTILITIES: PRIVATE WELL AND SEPTIC ON SITE. SEPTIC SYSTEM APPROVED BY VDH FOR UP TO 875 GPD. DRAINAGE DISTRICT: IVY CREEK - LITTLE IVY CREEK ZONING SITE REQUIREMENTS: USE CURRENT: VACANT PROPOSED: 6,500 SF GENERAL OFFICE PROPOSED OPEN SPACE: 0.29 ACRES (34% OF SITE) SETBACKS PRIMARY STREET FRONTAGE (IVY ROAD): 10' MINIMUM SIDE AND REAR: NONE BUILDING HEIGHT MAXIMUM ALLOWABLE BUILDING HEIGHT: 65 FT (COMMERCIAL DISTRICT) PARKING REQUIRED PARKING: GENERAL OFFICE: 1 SPACE PER 200 SQUARE FEET OF GFA 1 SPACE X (6,500 SF X 0.8) / 200 SF = 26 SPACES PARKING FOR ADJACENT PARCEL (4282 IVY ROAD): 7 SPACES TOTAL PARKING REQUIRED: 33 SPACES PARKING PROVIDED: 35 SPACES IMPERVIOUS AREA EXISTING IMPERVIOUS AREA: 0.19 ACRES PROPOSED IMPERVIOUS AREA: 0.48 ACRES NOTES: 1. LANDSCAPING SHALL BE PROVIDED PURSUANT TO SECTION 32.7.9 OF THE COUNTY ZONING ORDINANCE AND THE ARB DESIGN GUIDELINES. PROPOSED PAVED PARKING AND VEHICULAR CIRCULATION AREAS ARE 0.31 ACRES. 2. SITE LIGHTING SHALL BE PROVIDED PURSUANT TO SECTION 4.17 OF THE COUNTY ZONING ORDINANCE AND THE ARB DESIGN GUIDELINES. UTILITY DEMANDS ESTIMATED WATER USAGE: 875 GALLONS PER DAY VEHICLE TRIP GENERATION LAND USE: GENERAL OFFICE ITE CODE: 710 6,500 SF ADT (WEEKDAY): 9.74 TRIPS PER 1000 SF -> 64 AVERAGE DAILY TRIPS IVY PROPER INITIAL SITE PLAN COUNTY OF ALBEMARLE OCTOBER 2, 2020 4 g r Nf iJiYa 0. p 4 a a s3 PROJECT SITE qve n ae g` 4 VICINITY MAP SCALE 1" :1000' OWNER: LENVIC LLC 2506 BRANDERMILL PL CHARLOTTESVILLE, VA 22911 DEVELOPER: BUILDING MANAGEMENT CO. 400 LOCUST AVE, SUITE 3 CHARLOTTESVILLE, VA 22902 CONTACT: REID MURPHY PHONE: 434-977-6406 ENGINEER OF RECORD: TIMMONS GROUP 608 PRESTON AVENUE, SUITE 200 CHARLOTTESVILLE, VA 22903 CONTACT: CLINT SHIFFLETT, P.E. TELEPHONE: 434-327-1690 Sheet List Table Sheet Number Sheet Title C0.0 COVER C1.0 NOTES AND DETAILS C1.1 NOTES AND DETAILS C2.0 EXISTING CONDITIONS C4.0 SUP CONCEPT PLAN C4.1 SIGHT DISTANCE PROFILE C5.0 GRADING PLAN C6.0 CONCEPTUAL SWM PLAN C7.0 STORMWATER PROFILES TOTAL: 9 SHEETS SITE PLAN LEGEND EXISTING PROPERTY LINE POST/BOLLARD SIGN CONCRETE WHEEL STOP SATELLITE DISH TRAFFIC CONTROL BOX 0 UNKNOWN MANHOLE STORM SEWER O STORM SEWER MANHOLE 99 CATCH BASIN CATCH BASIN WITH DOME GRATE TRENCH DRAIN SAN— SANITARY SEWER SANITARY SEWER MANHOLE w— WATER LINE WATER MANHOLE 0 WATER VALVE WATER LINE MARKER FIRE HYDRANT MONITORING WELL c GAS LINE A GAS METER GAS VENT 4 GAS MARKER UGT— COMMUNICATIONS/TELEPHONE LINE O TELEPHONE/COMMUNICATIONS MANHOLE M TELEPHONE PEDESTAL COMMUNICATIONS VAULT UGc-- ELECTRIC LINE m ELECTRIC MANHOLE ELECTRIC PULLBOX m ELECTRIC METER fY UTILITY POLE DECIDUOUS TREE GUARDRAIL FENCEX— xxx— MAJOR CONTOUR Xxx- MINOR CONTOUR 0 SOIL BORING SURVEY CONTROL MONUMENT SURVEY CONTROL POINT PROPOSED w WATER G GAS STORM SANS SANITARY UGT COMM DUCT BANK UGr ELECTRIC DUCT BANK CATCH BASIN STORM MANHOLE SANITARY MANHOLE OO SANITARY CLEAN OUT P R-} FIRE HYDRANT FDC METER SETBACK - AT/FP STANDOFF WATER VALVE A GAS VALVE O BOLLARD STREET SIGN O GAS METER LIMITS OF DISTURBANCE GUARDRAIL X FENCE XXX MAJOR CONTOUR XXX MINOR CONTOUR Q SITE LIGHT PARKING SPACE COUNT GRADING TC = TOP OF CURB BC = BOTTOM OF CURB EP = EDGE OF PAVEMENT EC = EDGE OF CONCRETE TW = TOP OF WALL BW = BOTTOM OF WALL TS = TOP OF STAIRS BS = BOTTOM OF STAIRS N/A = NOT APPLICABLE TO THIS PROJECT CLINT W. $ S F LET Lic. N . 543110 ; 10-02-2020 Aml N z 0 f f AL Z0 UU LUw0 ZO w cke DATE 10-02-2020 DRAWN BY A. FONTAINE DESIGNED BY C. SHIFFLETT CHECKED BY C. SHIFFLETT SCALE W U) Z J Q ce z o> LU w 0 i U LL LU LULUmJ a a 0 LL a 1--I L IOB NO. 42932 SHEET NO. C0.0 GENERALNOTES T H 6;4 LEGEND ROADS SEWER CD g EXISTING SANITARY SEWER STORM PIPE & STRUCTURE NO. CD DROP INLET & STRUCTURE NO. WATER CURB 0 CURB & GUTTER BENCH MARK CLEARING LIMITS 200 - -- EXISTING CONTOUR 200 - PROPOSED CONTOUR 240.5 EXISTING SPOT ELEVATION TC 240.5 PROPOSED SPOT ELEVATION 1D PARKING COUNT ACSA GENERAL WATER & SEWER CONDITIONS EXISTING WATER LINE GRADING TC = TOP OF CURB BC = BACK OF CURB EP = EDGE OF PAVEMENT TW = TOP OF WALL BW = BOTTOM OF WALL TS = TOP OF STAIRS BS = BOTTOM OF STAIRS N/A = NOT APPLICABLE TO THIS PROJECT JUNE 27, 2019 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE ALBEMARLE COUNTY SERVICE AUTHORITY SHALL HAVE ACCESS TO USE THE AIRSPACE ABOVE THE LOCATIONS OF CONSTRUCTION FOR THE FLIGHT OF UNMANNED AERIAL VEHICLES FOR THE PURPOSE OF IMAGERY COLLECTION. 3. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 4. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 5. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 7. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 8. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 9. VALVES ON DEAD END LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. 10. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. 11. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO -LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). 12. THE SEWER LATERAL BEYOND THE CONNECTION AT THE SEWER MAIN SHALL BE PRIVATE. THE SEWER LATERAL STUB -OUT SHALL UNDERGO THE ACSA LOW-PRESSURE AIR TEST TO SATISFY COUNTY TESTING REQUIREMENTS. VISUAL INSPECTION OF THE SEWER LATERAL STUB -OUT SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 13. THE SEWER LATERAL BEYOND THE CONNECTION AT A MANHOLE SHALL BE PRIVATE. VISUAL INSPECTION AND PRESSURE TESTING OF THE SEWER LATERAL SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING' PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 14. THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE IS PRIVATE. VISUAL INSPECTION AND TESTING OF THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING' PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 15. ALL FLUSHING OF FIRE SPRINKLER MAINS SHALL NOT OCCUR UNTIL APPROVAL IS GIVEN BY THE ACSA. 16. ALL WATER AND SEWER FACILITIES TO BE DEDICATED TO PUBLIC USE AND THE EASEMENTS FOR THOSE FACILITIES AND SHALL BE IDENTIFIED BY A STATEMENT THAT THE FACILITIES ARE TO BE DEDICATED TO THE ALBEMARLE COUNTY SERVICE AUTHORITY. GENERAL CONSTRUCTION NOTES FOR EROSION AND SEDIMENT CONTROL 1. THE PLAN APPROVING AUTHORITY MUST BE NOTIFIED ONE WEEK PRIOR TO THE PRE -CONSTRUCTION CONFERENCE, ONE WEEK PRIOR TO THE COMMENCEMENT OF LAND DISTURBING ACTIVITY, AND ONE WEEK PRIOR TO THE FINAL INSPECTION. 2. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CONSTRUCTED AND MAINTAINED ACCORDING TO MINIMUM STANDARDS AND SPECIFICATIONS OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK AND VIRGINIA REGULATIONS VR 625-02-00 EROSION AND SEDIMENT CONTROL REGULATIONS. 3. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO OR AS THE FIRST STEP IN CLEARING. 4. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. 5. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO, OFF -SITE BORROW OR WASTE AREAS), THE CONTRACTOR SHALL SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND APPROVAL BY THE PLAN APPROVING AUTHORITY. 6. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY ADDITIONAL EROSION CONTROL MEASURES NECESSARY TO PREVENT EROSION AND SEDIMENTATION AS DETERMINED BY THE PLAN APPROVING AUTHORITY. 7. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. 8. DURING DEWATERING OPERATIONS, WATER WILL BE PUMPED INTO AN APPROVED FILTERING DEVICE. 9. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. 10. ALL FILL MATERIAL TO BE TAKEN FROM AN APPROVED, DESIGNATED BORROW AREA. 11. ALL WASTE MATERIALS SHALL BE TAKEN TO AN APPROVED WASTE AREA. EARTH FILL SHALL BE INERT MATERIALS ONLY, FREE OF ROOTS, STUMPS, WOOD, RUBBISH, AND OTHER DEBRIS. 12. BORROW OR WASTE AREAS ARE TO BE RECLAIMED WITHIN 7 DAYS OF COMPLETION PER ZONING ORDINANCE SECTION 5.1.28. 13. ALL INERT MATERIALS SHALL BE TRANSPORTED IN COMPLIANCE WITH SECTION 13-301 OF THE CODE OF ALBEMARLE. 14. BORROW, FILL OR WASTE ACTIVITY INVOLVING INDUSTRIAL -TYPE POWER EQUIPMENT SHALL BE LIMITED TO THE HOURS OF 7:OOAM TO 9:OOPM. 15. BORROW, FILL OR WASTE ACTIVITY SHALL BE CONDUCTED IN A SAFE MANNER THAT MAINTAINS LATERAL SUPPORT, OR ORDER TO MINIMIZE ANY HAZARD TO PERSONS, PHYSICAL DAMAGE TO ADJACENT LAND AND STRUCTURES/IMPROVEMENTS, AND DAMAGE TO ANY PUBLIC STREET BECAUSE OF SLIDES, SINKING, OR COLLAPSE. 16. THE DEVELOPER SHALL RESERVE THE RIGHT TO INSTALL, MAINTAIN, REMOVE OR CONVERT TO PERMANENT STORMWATER MANAGEMENT FACILITIES WHERE APPLICABLE ALL EROSION CONTROL MEASURES REQUIRED BY THIS PLAN REGARDLESS OF THE SALE OF ANY LOT, UNIT, BUILDING OR OTHER PORTION OF THE PROPERTY. 17. TEMPORARY STABILIZATION SHALL BE TEMPORARY SEEDING AND MULCHING. SEEDING IS TO BE AT 75 LBS/ACRE, AND IN THE MONTHS OF SEPTEMBER TO FEBRUARY TO CONSIST A 50/50 MIX OF ANNUAL RYEGRASS AND CEREAL WINTER RYE, OR IN MARCH AND APRIL TO CONSIST OF ANNUAL RYE, OR MAY THROUGH AUGUST TO CONSIST OF GERMAN MILLET. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 18. PERMANENT STABILIZATION SHALL BE LIME AND FERTILIZER, PERMANENT SEEDING, AND MULCH. AGRICULTURAL GRADE LIMESTONE SHALL BE APPLIED AT 90LBS/1000SF, INCORPORATED INTO THE TOP 4-6 INCHES OF SOIL. FERTILIZER SHALL BE APPLIED AT 1000LBS/ACRE AND CONSIST OF A 10-20-10 NUTRIENT MIX. PERMANENT SEEDING SHALL BE APPLIED AT 180LBS/ACRE AND CONSIST OF 95% KENTUCKY 31 OR TALL FESCUE AND 0-5% PERENNIAL RYEGRASS OR KENTUCKY BLUEGRASS. STRAW MULCH IS TO BE APPLIED AT 80LBS/100SF. ALTERNATIVES ARE SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 19. MAINTENANCE: ALL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL EVENT. ANY DAMAGE OR CLOGGING TO STRUCTURAL MEASURES SHALL BE REPAIRED IMMEDIATELY. SILT TRAPS SHALL BE CLEANED WHEN 50% OF THE WET STORAGE VOLUME IS FILLED WITH SEDIMENT. ALL SEEDED AREAS SHALL BE RESEEDED WHEN NECESSARY TO ACHIEVE A GOOD STAND OF GRASS. SILT FENCE AND DIVERSION DYKES WHICH COLLECT SEDIMENT TO HALF THEIR HEIGHT MUST BE CLEANED AND REPAIRED IMMEDIATELY. 20. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS OF FINAL SITE STABILIZATION, WHEN MEASURES ARE NO LONGER NEEDED, SUBJECT TO APPROVAL BY THE COUNTY EROSION CONTROL INSPECTOR. 21. THIS PLAN SHALL BE VOID IF THE OWNER DOES NOT OBTAIN A PERMIT WTIHIN 1 YEAR OF THE DATE OF APPROVAL. (WATER PROTECTION ORDINANCE SECTION 17-204G.) 22. PERMANENT VEGETATION SHALL BE INSTALLED ON ALL DENUDED AREAS WITHIN NINE (9) MONTHS AFTER THE DATE THE LAND DISTURBING ACTIVITY COMMENCED. (WATER PROTECTION ORDINANCE SECTION 17-207B) 1. CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS FOR AS BUILT DOCUMENTATION, AS REQUIRED BY THE LOCALITY. THIS INCLUDES, BUT IS NOT LIMITED TO, TESTING, INSTALLATION DOCUMENTATION, SURVEY, ETC. ALL REQUIREMENTS SHALL BE DISCUSSED WITH THE LOCALITY PRIOR TO THE BEGINNING CONSTRUCTION. 2. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION'S SPECIFICATIONS AND STANDARDS. 3. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR SHALL CONSULT THE ENGINEER AND VERIFY THE APPROVAL OF THE PLANS BY ALL FEDERAL, STATE AND LOCAL AGENCIES. 3. LAND USE PERMITS (LUP-A) MUST BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION PRIOR TO BEGINNING ANY CONSTRUCTION WITHIN THE EXISTING STATE MAINTAINED RIGHT OF WAY (INCLUDING ACCESS). 4. VDOT IS TO RECEIVE WRITTEN NOTIFICATION 48 HOURS PRIOR TO COMMENCING WITH INITIAL CONSTRUCTION ACTIVITIES. 5. THE CONTRACTOR SHALL VERIFY THE ELEVATIONS OF ALL POINTS OF CONNECTION OR PROPOSED WORK TO EXISTING CURBS, SANITARY LINES, WATERLINES, ETC, PRIOR TO CONSTRUCTION. 6. UPON DISCOVERY OF SOILS THAT ARE UNSUITABLE FOR FOUNDATIONS, SUBGRADES, OR OTHER ROADWAY CONSTRUCTION PURPOSES, THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE OWNER. THESE AREAS SHALL BE EXCAVATED BELOW PLAN GRADE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED IN ACCORDANCE WITH SPECIFICATIONS. 7. ALL STORM SEWER DESIGN AND CONSTRUCTION TO BE IN ACCORDANCE WITH VDOT STANDARDS. 8. ALL STORM SEWER PIPE SHALL BE REINFORCED TONGUE AND GROVE CONCRETE PIPE IN ACCORDANCE WITH ASTM-C-76. PIPE WITHIN THE RIGHT OF WAY SHALL BE MINIMUM CLASS III OR GREATER IN ACCORDANCE WITH CURRENT VDOT STANDARDS AND SPECIFICATIONS. 9. IF PRE -CAST UNITS ARE TO BE USED, VDOT SHALL BE NOTIFIED AND THE MANUFACTURER SHALL SUBMIT DRAWING DETAILS FOR REVIEW. CERTIFICATION AND VDOT STAMP WILL BE REQUIRED ON ALL UNITS. 10. ALL CONCRETE SHALL BE A3-AE (AIR ENTRAINED 3,000 PSI), UNLESS OTHERWISE NOTED. 11. ALL ENTRANCES ARE TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CURRENT VDOT STANDARDS. 12. DESIGN CHANGES, SPECIFIED MATERIALS CHANGES AND/OR FIELD CHANGES FROM THE APPROVED PLANS NEED TO BE RESUBMITTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. A LETTER OF EXPLANATION SHALL ACCOMPANY THE REVISED PLANS AND/OR THE DRAINAGE CALCULATIONS, WHICH MUST BE SUBMITTED AND APPROVED BY THE ENGINEER. 13. CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON PLAN. IF THERE APPEARS TO BE A CONFLICT, AND/OR UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THIS PLAN, CALL MISS UTILITY OF CENTRAL VIRGINIA AT 1-800-552-7001. THE OWNER SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY UTILITY WITHIN EXISTING AND/OR PROPOSED RIGHT-OF-WAY REQUIRED BY THE DEVELOPMENT. 14. CASING SLEEVES SHALL BE PLACED AT ALL ROAD CROSSINGS FOR GAS, POWER, TELEPHONE AND CABLE TV SERVICE TRUNK LINES. (N/A) 15. THE INSTALLATION OF SEWER, WATER, AND GAS MAINS (INCLUDING SERVICE LATERALS AND SLEEVES) SHALL BE COMPLETED PRIOR TO THE PLACEMENT OF AGGREGATE BASE COURSE. 16. VDOT & ALBEMARLE COUNTY APPROVAL OF CONSTRUCTION PLANS DOES NOT PRECLUDE THE RIGHT TO REQUIRE ADDITIONAL FACILITIES AS DEEMED NECESSARY. 17. VDOT SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER'S REPRESENTATIVE FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 18. A PRIME COAT SEAL BETWEEN THE AGGREGATE BASE AND BITUMINOUS CONCRETE WILL BE REQUIRED AT THE RATE OF 0.30 GALLONS PER SQUARE YARD (REC-250 PRIME COAT) PER VDOT STANDARDS AND SPECIFICATIONS. 19. THE SCHEDULING OF AGGREGATE BASE INSTALLATION AND SUBSEQUENT PAVING ACTIVITIES SHALL ACCOMMODATE FORECAST WEATHER CONDITIONS PER SECTION 315 OF THE ROAD AND BRIDGE SPECIFICATIONS. 20. THE OWNER'S REPRESENTATIVE SHALL HAVE APPROVED THE AGGREGATE BASE COURSE(S) FOR DEPTH, TEMPLATE AND PERFORMED THE REQUIRED FIELD INSPECTION (PROOF ROLL) PRIOR TO PLACEMENT OF ANY SURFACE COURSE(S). CONTACT THE OWNER FOR INSPECTION FOR THE AGGREGATE BASE COURSE(S) 48 HOURS PRIOR TO APPLICATION OF THE SURFACE COURSE(S). 21. A GEOTECHNICAL ENGINEER IS TO ASCERTAIN CAUSE AND CERTIFY RECOMMENDED METHOD OF REPAIR FOR ALL PAVEMENT STRUCTURAL FAILURES PRIOR TO STATE ACCEPTANCE. (N/A) 22. ALL VEGETATION AND ORGANIC MATERIAL IS TO BE REMOVED FROM THE PROPOSED PAVEMENT LIMITS PRIOR TO CONDITIONING OF THE SUBGRADE. 23. CERTIFICATION AND SOURCE OF MATERIALS ARE TO BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR ALL MATERIALS AND BE IN ACCORDANCE WITH THE ROAD AND BRIDGE SPECIFICATIONS, AND ROAD AND BRIDGE STANDARDS. 24. APPROVAL OF A DETAILED CONSTRUCTION SEQUENCING/MAINTENANCE OF TRAFFIC NARRATIVE FOR THE WORK ZONE IS A PREREQUISITE FOR ISSUANCE OF A LAND USE PERMIT ALLOWING ACCESS TO AND CONSTRUCTION WITHIN VDOT MAINTAINED RIGHT OF WAY. (N/A) 25. GRADE LINES ON PROFILES DENOTE FINISHED GRADE OF CENTER LINE OF ROAD. (N/A) 26. ALL APPROACH GUTTERS TO SAG INLETS SHALL MAINTAIN A MINIMUM SLOPE OF 0.004 ft./ft. 27. WHERE A TYPE "B" NOSE IS SPECIFIED ON AN INLET IN CONJUNCTION WITH ROLL FACE CURB AND GUTTER OR CG-7, THERE SHALL BE A 20' TRANSITION ON EACH SIDE OF THE INLET. (N/A) 28. CONTRACTOR SHALL PROVIDE A SEQUENCE OF CONSTRUCTION/MAINTENANCE OF TRAFFIC PLAN IN ACCORDANCE WITH THE STANDARDS AND GUIDELINES CONTAINED IN THE 2011 EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL FOR REVIEW BY THE ENGINEER, OWNER'S REPRESENTATIVE, AND VDOT PRIOR TO STARTING WORK THAT IMPACTS TRAFFIC ON STATE ROADS. 29. ALL NEW HANDICAP ACCESSIBLE REQUIREMENTS ON -SITE AND WITHIN ALL NEW STRUCTURES SHALL COMPLY WITH THE 2006 UNIFORM STATEWIDE BUILDING CODE, 2006 VIRGINIA CONSTRUCTION CODE, AND ICC/ANSI A117.1-03. 30. THE CLEAR ZONE IS TO BE FREE OF STORED MATERIALS AND PARKED EQUIPMENT. 31. HORIZONTAL AND VERTICAL SIGHT DISTANCES SHALL BE FREE OF PARKED VEHICLES. 32. ALL EXCAVATED AREAS WITHIN THE CLEAR ZONE THAT HAVE A DEPTH GREATER THAN 6" SHALL HAVE A 6:1 STONE WEDGE PLACED AT THE END OF THE DAY 33. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 34. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL NOT HAVE A SURFACE SLOPE GREATER THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACE THEY SERVE. ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AND ACCESSIBLE BUILDING ENTRANCE. IN PARKING FACILITIES THAT DO NOT SERVE A PARTICULAR BUILDING, ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ROUTE TO AN ACCESSIBLE PEDESTRIAN ENTRANCE TO THE PARKING FACILITY. WHERE BUILDINGS HAVE MULTIPLE ACCESSIBLE ENTRANCES WITH ADJACENT PARKING, ACCESSIBLE PARKING SPACES SHALL BE DISPERSED AND LOCATED NEAR THE ACCESSIBLE ENTRANCES. 35. ALL ROOF DRAINS SHALL DISCHARGE IN A MANNER NOT TO CAUSE A PUBLIC NUISANCE AND NOT OVER SIDEWALKS. ALBEMARLE COUNTY ENGINEERING GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT OF WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT. 3. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND MUST BE INSTALLED PRIOR TO ANY CLEARING GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2:1 (HORIZONTAL:VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:1 OR BETTER ARE TO BE ACHIEVED. 6. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS III. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). 10. RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN ALSO. WALLS REQUIRE INSPECTIONS AS OUTLINED IN THE USBC. 11. ALL WATER LINES, SEWER LINES AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. BLASTING NOTES CLINT W. !:iZ S FFLET > Lic. N SIJSO 4 10-02-2020 G •• i 0010i 064` am O cc t7 N 1. BLASTING SHALL NOT BE PERMITTED ON THIS PROJECT. ALBEMARLE COUNTY STORMWATER MANAGEMENT NOTES I z 1. ALL DAMS AND CONSTRUCTED FILL TO BE WITHIN 95% OF MAXIMUM DRY DENSITY AND 2% OF OPTIMUM MOISTURE CONTENT. ALL FILL MATERIAL TO BE APPROVED BY A GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS TO BE PRESENT DURING CONSTRUCTION OF DAMS. 2. PIPE AND RISER JOINTS ARE TO BE WATERTIGHT WITHIN STORMWATER MANAGEMENT FACILITIES. 3. FOR TEMPORARY SEDIMENT TRAPS OR BASINS WHICH ARE TO BE CONVERTED TO PERMANENT STORMWATER MANAGEMENT FACILITIES; CONVERSION IS NOT TO TAKE PLACE UNTIL THE SITE IS STABILIZED, AND PERMISSION HAS BEEN OBTAINED FROM THE COUNTY EROSION CONTROL INSPECTOR. 0 E H DATE 10-02-2020 DRAWN BY A. FONTAINE DESIGNED BY C. SHIFFLETT CHECKED BY C. SHIFFLETT SCALE N/A Lu I- 1 Q V/ z J J I- Lu Q Z z O z I- U Lu Q i IY w Lu m O Q z O I- JOB NO. 42932 L SHEET NO. C1.0 4" CNLTH 0i 00 EXPANSION JOINT WITH TOP OF CURB j"j R=2" yPREMOLDEDEXPANSION1/4" SEALANT ZIPFILLER, STRIP" OR NON -SLIP BROOM FINISH CLINT W. S OEQUIV., SEAL WITH SILICONE SEALANT WWF6x6W2.9xW2.9 2" 6" V $ V LET > 54380 40 10" 3,000 PSI AIR ENTRAINED PORTLAND SURFACE I ic. N . 10-02-2020 A,3 I CEMENT CONCRETE 18 jj jj j a' ,d ° ° sS/AL twso 0 0 0 0 0 0 0 0 6" TYPE 21 A STONE COVER MCOMPACTEDSUBGRADE (CBR 11.2)° a O o VDOT A-3 CONCRETE N N SUBBASES N EXISTGRAD METAL INSPECTION FRAME W/SOLID LID NEENAH R-1975 OR EQUIVALENT) DENOTES CONCRETE SERVICE AREA PAVEMENT ON PLANS w a E 3"CONCRETE COLLAR H w ,„ 3 RUSHED STONE BEDDING CONTINUE 2IB STONE BASE Q LL o 3 HEAVY DUTY CONCRETE SECTION FROM ADJACENT PAVEMENT 0 U.— 6"DICLEANOUT SECTION UNDER CURB W t Md _j i5 z0NoScales d NVDOTSTANDARDCG-2 CURB o a NO Scale PLUG AT END OFLINE SIGN u w STD. U POST s ry 0 Z CLEANOUT DETAIL GALVANIZED x ¢' mF O 4" 2 R S NNoScale d . CONIC CURB AND GUTTER CLASS 3A, a v Pc=3,000 PSI) CONCRETE o w SIGNAGE NOTES: 6„ 1. ALL SIGNING AND PAVEMENT MARKING SHALL BE IN ACCORDANCE WITH 6 THE MOST CURRENT EDITION OF EACH OF THE FOLLOWING AND ANY 13" ° ° ° °- REVISION THERE TO: REFER TO VDOT STD STP-1 DETAIL j ° : ° a ° 7" O A. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. FOR MOUNTING REQUIREMENTS B. THE VIRGINIA SUPPLEMENT TO THE MANUAL ON UNIFORM TRAFFIC m ° a O CONTROL DEVICES. a a ° 0 C. THE VIRGINIA DEPARTMENT OF TRANSPORTATION ROAD AND BRIDGE SPECIFICATIONS. w D. THE 2000 INTERNATIONAL FIRE CODE. 4" MIN. Luw x 2. SIGN LOCATIONS ARE APPROXIMATE AND ARE TO BE MODIFIED IN THE a FIELD TO AVOID CONFLICT WITH UNDERGROUND UTILITIES OR OTHER IIIIIIIIIIIIIII—III- 6" 6" 2'4" Z 0 DATECONSTRUCTIONS, AND TO COMPLY WITH STANDARDS REFERENCED IN CONTINUE 21B STONE NOTE 1 ABOVE. COMPACTED BASE FROM ADJACENT SIGN AND POST DETAIL SUBGRADE PAVEMENT SECTION 10 02-2020 3. ALL SIGNS AND PAVEMENT MARKINGS ARE TO BE FURNISHED AND UNDER CURB 0NoScale DRAWN BYINSTALLEDBYTHECONTRACTOR. ALL SIGNS TO BE FURNISHED AND FIB MOM INSTALLED WITH STANDARD U POST GALVANIZED BY THE CONTRACTOR. A. FONTAINE SOLID WHITE LINE 24" r(TYP.) p9m pffm VDOT STANDARD CG-6 CURB & GUTTER DESIGNED BY C. SHIFFLETT No Scale CHECKED BYST0PI} 2" ASPHALTIC CONCRETE SURFACE 12 PwLTY COURSE - SM-9.5A C. SHIFFLETT SM -$5WRE MOW7WAYTZONE SCALESTD. (VARIES) R1-1 TOW AWAY ZOPE 8" TYPE 21-B AGGREGATE SUBBASE COURSE NIA STOP BAR DETAILNOTE: STOP SIGNS TO BE 30" WITH HIGH INTENSITY SHEETING NO SCALE 6' ABOVE AOLE 6' ABOVE FINISHED FINISHED COMPACTED SUBGRADE GRADE GRADE PER GEOTECHNICAL REPORT) SPACES SHALL BE IDENTIFIED BY ABOVE GRADE SIGNS AS RESERVED FOR SOLID WHITE LINE PHYSICALLY DISABLED PERSONS. PROVIDE ONE (1) R-7-8 SIGN AT EACH PARKING SPACE INDICATED ON SITE PLAN. SIGN SHALL BE ALUMINUM (PAINTED WHITE) DENOTES LIGHT DUTY ASPHALT PAVEMENT ON PLANSQLLzD WITH GREEN LETTERS AND INTERNATIONAL WHEELCHAIR SYMBOL. SIGN SHALL BE PLACED ON STEEL POST 1-1/2" O PAINTED BLACK SET IN MIN. 2' OF CONCRETE. LIGHT DUTY ASPHALT PAVEMENT SECTION6' VA. SIGN FOR THE DISABLED ON 0.80 GAUGE No Scale ALUMINUM. COLORS: GREEN BORDER & LEGEND, BLUE SYMBOL FOR ACCESSIBILITY, Z 2' 2' WHITE BACKGROUND. 2" ASPHALTIC CONCRETE SURFACE QTYP.) (TYP.) COURSE - SM-9.5A JPARKINGSIGNSFORTHEDISABLED3" INTERMEDIATE BASE COURSE - BM25.OA 0 0 0 oSTRIPINGANDSIGNAGEDETAIL No scale W No Scale 8" TYPE 21-B AGGREGATE SUBBASE COURSE CONCRETE BUMPER BLOCK CONCRETE BUMPER BLOCK Q ANCHOR H 5/8" REBAR AS NOTED ON C40 & C41 IMBEDDED 24IN GROUND HANDICAP SIGN .. U7 OVERLAP LOCATION ( VAN) HANDICAP SIGN LOCATION ( TYP.) COMPACTED SUBGRADE PER GEOTECHNICAL REPORT) J Q w 6" TYPE 21-B AGGREGATE I— FABRIC 8" MIN. o BASE COURSE 2' _ 2' 2' DENOTES HEAVY DUTY ASPHALT PAVEMENT ON PLANS Z 0 o o z0Z 8\%\\/\\\%' COMPACTED SUBGRADE EOP FCURBACE F U Z PAINTED HEAVY DUTY ASPHALT PAVEMENT SECTION I —I VDOT# 57 FILTER FABRIC WRAP 18 1s a W STONE12" MIRAFI 140N OR EQUIV. 4„ 4" DIA. PERFORATED 4„ SPEC. PAINTED w PVC PIPE STRIPE W °' TYPICAL) 8 5 8 8 8 J aZ TYPICAL VAN NON - SLIP BROOM FINISH O 4" DIAMETER STEEL DENOTES GRAVEL SECTION ON PLANS p p p ACCESSIBLE ACCESSIBLE PIPE FILLED WITH CONCRETE. BOLLARD HANDICAP SPACES REGULAR SPACE GRAVEL SECTION TYPICAL PARKING SPACE DETAILS SHALLBEPAINTEDVARIABLE WIDTH' YELLOW MAX. CROSS SLOPE 2% No Scale No Scale 4 PAVEMENT 1.5" 2" BITUMINOUS CONCRETE SURFACE COURSE SM 9.5A 2' FROM EP q. 7- 1/2" 2'- 0" DIAMETER 6' LENGTH 4" 3,000 PSI AIR -ENTRAINED CONIC. FOOTING CONCRETE a 6". 5 COMPACTED SUBGRADE 4" TYPE 21 B STONE COVER Ep EXISTING AGGREGATE BASE X/ Cy ANCHOR WITH 5REBAR IMBEDDED 24" IN GROUND; 5' i COMPACTED SUBGRADE 2 PER WHEEL STOP NOTE: SIDEWALKS SHALL BE CONSTRUCTED IN 3.5' ACCORDANCE WITH VDOT STANDARDS. 4 MILL AND OVERLAY SEQUENCE: REMOVE O ROLLTEST EXISTING BASE COMPACT N COURSE. JOB No. u NEW ASPHALT SURFACE. DENOTES CONCRETE SIDEWALK PAVEMENT ON PLANS 42932 BOLLARD DETAIL CURB TRANSITION DETAIL MILL AND OVERLAY PAVEMENT SECTION PRECAST CONCRETE WHEEL STOP CONCRETE SIDEWALK PAVEMENT SECTION SHEET NO. C1.1 No ScaleNoScaleNoScaleNoScaleNoScaleL 0 0 0 0 24"HDPE 0 0 0 o lNV=537.13 0 0 o - 0 0 00 I I ' y39 --- 0 0 00 0 0 1 1' EXTENTS OF / o 0 0 0 00 1I J/ 500-YFLOODPLAN / //// 0000000 0° 0000 ill v C& 0RAIMBRANCH Ro28 4$ X536.2' / \ X53o9. 30' 04go / o/ 000 0 0 1 1 BOCKINWIOTH R.0 W T-89•07 1„ d o 0 0 00 0 0 0 ° 000 ' '1 / / 0 1 1 _ A-4°Nj5°pg50 E / ' o% ° ° 0 0 ° ° / / / i 24" HDPE I 1 C6= g9, ' ° ° ° _ / co / / zl // o ° 0 INV=53588 I I _ - - ' - C;177 / 0 0 o d ° 0 0 0 0 - _ _ _ _ - , , _ _ _ _ _ _ _ o 0 0 0 0 0 0 0 _ - - - - - moo-' I ono- 0 0 0 0 0 0 0 0 0 ° °'°g° ° ° 0 01+0 ° ° ° 0/, o / z/ - - - - - - - 538 l X5353' / _ - - - - - _ _ _ - - - - i ' l/ l l l l TMP 58A2-21 04' / / _ _ _ CRITICAL SLOPES, TYP. - - - - - - - \ ` l / l / / l/ l l /l ROGER L. GIBSON AND rpTAL) , ` _ 29 4.8 - - - - - - - - - ` \ l/l /l/ /ll / STEPHENSON L. GIBSON 167. 78' \/ll l/l D.B.1597,PG. 226 535 %-__-- - 77°35'55"E _ --- 533-------- - - - D.B. 231, PG.585 D. 8.130,PG. 109 530 138. N 530X 523.5' 1. 5'CONC. BLOCK BRIDGE ABUTMENT 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 T3= 2"BRIDGE HEIGHT SIGN O O O 0 0 O O O 0 O OVERHEAD- PowES LINE TO BE - - - - - - _ _ _ _ _ ?4 \ 1 I I If I , RELOCATED. COORDINATENEVIh REMOV LOCATION WITH DOMINION - _ - - - - - _ _ BOARDF X521. 4' 523- _- 5 . 3' S . 4' -- -- - - - -\ h• 4' \ TMP 58A2-20 X 520.5' ` f l LENVIC, LLC Al D. B`3W, PG. 7550 i - 1 Oca SAWCUT R= 1179.40' EP F P IC REMOVE D.B. 469, PG. 009 L= 20.89' E V 5 .7 ' GRAVEL 0.76ACRES REMOVE T= 10.45' X 519.5' BOARD FENCE A= 1°0053" I /} C8= N5504048"W C= 20.89' o. oryGrF \ R \ X 5>8.7' j 4'' o. So ` \ Xg7j0 \ TMP 58A2-20A R SBA o \ JOSEPH W. RICHMOND, JR X 519.4' ` 4 9 g' TRUSTEE 9N } D.B. 4992, PG. 686 D. B. 821, PG.218 7, 2 ' \ - 518 - I D.B. 268, PG.151 2 7 SIGNTE X 518.6' \ Q 1 1 si Si 1 e NO7F °SD ° 0 TOP= LETIWGRATE o 0 0 SAWCUT X516.5' 0 INV. IN=513.45'4"PVC 0 515. 15 ° ° liyF X5176' \ B " CONNECTION UNKNOWN o o ° IvINV. OUT=511.60'24"CMP o 0 516- - 0 0 p o 0 0 O OA o O O 0 0 0 0 0 o q/ YEAR q b EXTENTS OF o ° o ° 24" CMP W/BROKEN ° FLOODODPLA/N 0 HEADWALL i o o INV. 511.Oa' ° 0 0 0 // I/III-, I 0 ° ° ° ° ° y^IN III 515 o o ° / //b / 11 0 0 0 0 I/ 000 . 000000 o 0 0 0 0 0 0 0 o o o o o o 0 o o .0 00 0 0 0 .0 0 0 00 o° o 0 0 0 TMP58A2- 14 pN' VACATE ----- \ \ \ / r161111h1 LE- N19G,ELC-523-------- - PR \ \ 1 1 IIIIIIIIIN, X522.6' D. B. 3801, PG. 750 101! II I I D. B.470, PG.01 ' - - - - 525 X 530.1' 1 IIII 1 I D.B. 469, PG. 009 o X 522.6' _- --_--------\11 0.11 ACRES ' -l- - _ _ - - - s I III I I I I It 522 - 5 c+) co SCALE1 "= 20' 0 20' 40' f•-44t l.Tll Op',• C CLINT W. x: v S F LET Lie. N 51380 ? 10-02- 2020woo fy', G M E O OUN NCQOEvE w 3 w wQLL 3 p LL w oLumV 00z w u O rn C7w a w v 30 x U) w 0Xc ry z O FvwcU) o nO W M Lu 00 H 0 x c 0pw Lw H Qz 0 V) DATE 10-02- 2020 0 DRAWN BY A. FONTAINE DESIGNED BY C. SHIFFLETT CHECKED BY C. SHIFFLETT am O oc t7 SCALE i" = 20' JOB NO. 42932 L SHEET NO. Cz. 0 0 0 O 0 0 0 24"HDPE 0 o 0 /NV=537.13 0 o O ° 0 1 13UCKINGHAM BRANCH RAILROAD APPROXIMATE LOCATION OF 0' oj- -0 00000° 00/ RIMARYDRAI539 00° 0 I/ EXTENTS °/ / oo° o AN °° o0 LON' 0° oRAIRCHo00pMBRA0O 00 00 II ONNROW 0 1 1 BUr'KVIIDT--- ---- i 0 0 00 11 So• APPR)XNIATE LOCATION 00000 00 /It yiORSERVE DRAIN FIELD 0 0° HDPE o 24 o oINV=535.88 I I 'F0 0 ETAIN G WALLS_ Oi o° 0 0 0" So 0 0 ° 0/ 0 00 A_ii - 0-O o°° 0 o G°o o 0 0 0 o- o-o CRITICAL SLOPES, TYP. - - - - - - - - - - - - / l l l /11 /lI / TMP 58A2-21 ROGER L. GIBSON AND PHENSON L. 533- J I - - ---- --- — — — — — — — — — \- ---\ l/l!/l/ STED.B-1597,PG.2260N 535 kQAIMNGVGALL---------- -_--_- -. /l 11/l D.B. 231, PG.585 IO AX-HEIGHT=4_5- - -__--- ---- _ ---- ------ \ 11/llll l D.B. 130,PG.109 APPROXIMATE 1.5' CONC. BLOCK q - - - - - LOCATION OF _ _ _ - _ - BRIDGEABUTMENT 2 WELL - - -- - -- 52 ---- y 525 — — \ \ 1 1 III I 1 I 24, -TYP. _ \ \ \ 1 1 - JI I I I I I I I III j 3'-2"BRIDGE HEIGHT SIGN 522-' u R5' m 6, 500 SF FFE = 522.00j \ TMP 58A2- 20 RT Z , LENVIC, LLC R iI • D.8r`3W, PG. 750 D.B.470, PG.09 a 0'e(i D.B. 469, PG. 009 520 — " r TIE TO EXISTING PAVEMENT 0.76 ACRES CONCEPTUAL PLANTING LOCATIONS T9q 3 SHOWN. LANDSCAPE PLAN PROVIDED j C _ _ y R5' WITH FINAL SITE PLAN SHALL MEET ALL APPLICABLE COUNTY REQUIREMENTS. SHARED ACCESS AND PARKING AGREEMENT SHALL BE SUBMITTED AND APPROVED PRIOR O7 TO FINAL SITE PLAN APPROVAL. DUMPSTER PAD AND ENCLOSURE 41 TMP 58A2- 20A JOSEPH W. RICHMOND, JR TRUSTEE D.B. 4992, PG. 86 D.B. 82121,PG.218 I D.B. 268, PG. 151 F O/I'Y F CG-11 \ I/ 0 ° ENT CO RCIAL o E n \ 15 8\ 0 0 SD / W G ooGe F F\ I / NTOP- 515. 0 o/y ` / / p INV. IN=513.45 0 /1F 1 "CONNECTIOI I R v INV. OUT= 511. ° 0 1 II 516- 0 - s/ IN O o / O 0 00 EX.10 % 00 0 0 0 / ° 0 O o / o 0 o // O o o ° ° ° 0 ° q/q EXTENTS OF o ° o 0 24"CMP W/ BROKEN o° / f00-YEAR FLOODPLA/N o HEADWALL i o o INV. 511. Oa' ° O 0 ° ° ° o ° 0 ° ° 0 y^/ ry 111 515 O o ° / Ilb 111 000000 . 000000 o o O° 0 0 0 0 o o o o o 0 0 o o .0 0 0000 0 0 .0 000000000 O 0' 0 O E 0 ° 00PVC 0 ° JKNOWN o ° 24" CMP 0 0 ° 0 O 0 O 0 O00SCALE1 "= 20' 0 20' 40' f•-44t l.Tll Op',• C CLINT W. x: v S F LET Lie. N 51380 ? 10-02- 2020woo fy', G M E O O U N NCQOEvEw3w w Q LL 3pLL w 0 m j V20zn O rn Nv a fn W w j XU) w Ln i c ryz O Fva c U) NWw W M 00 HO x C7 0 p w wHz ODATE 10-02- 2020O DRAWN BY A. FONTAINE DESIGNED BY C. SHIFFLETT CHECKED BY C. SHIFFLETT Lm SCALE 1" = 20' uj Z J z0U Lu w z O oC w U W i a a- D JOB NO. 42932 SHEET NO. C4.0 L i i_ = =_'/ / / -_ II <BdD gU WIDTH R.o'%'/// //' i----- j- // // a 0 0 o ° p O l ice' -- -__ `\-_'/ /' / / /l IT- 0 II -__'' pp/o o,se'O/ pO o/ l o ° - - ' o o o o 0 0 O / / / - - - - - - - / /% / iZ o .0 0 9. a- ono=o- -o _o= — II 1 N" --_ - I I T` 39r' ___ I I I/ / / / / , r r IIIII / r/ I fl Illli I cj / • r I I I \ \ — \ •- \ ' // / / r / I IIIII I r I I I I \ \ r f I I I \\ \ r I o_ o ° o o o o ° 0 0 p ° / \ / \ 1 j / \ / 1 / o o ° sw ` // / / 1 / 0 Go0oop//'/ z- _ / /'/ \ \<<o<'NF \\ ` / I \\'y p ° o ° o / j Q o \ I CFFT / II 1 1 /_ °oo -\ _'' _-' o rT \ I 1 \ r' /' / p° p Ooo.00000": 0°°°'0° ' ' / \ `\\ \ `\ //` 01ti O r / / _ o /---- O \ b 0 of f- HEIGHT OF HEIGHT OF 530 OBJECT = 3.5' OBJECT = 3.5' 530 SDR - 390' EIGHT OF SDL - 390' 525 EYE = 3.5' 525 IL 520 520 515 515 EXISTING GRADE 510 510 IVY ROAD POSTED SPEED LIMIT: 35 MPH 505 505 119+ 50 10+00 11+00 12+00 13+00 14+00 15+00 IVY ROAD SIGHT DISTANCE PROFILE HORIZ SCALE: 1 "=50' VERT SCALE: 1 "=5 16+ 00 17+00 18+00 o pjJ 11 %F /,t' 0 CLINT W. x: S F LET A Lie. N 54380 ? 10- 02-20206 CGM E 0rnuN NC E v E w Q LL o 3 p LL wOLu mom V 00 z w u O rn a w 30' x n< U) oa w LLi c ry z OFva c U) LU W M lo H- M O x C70F 0 wL w HQ z ODATE 10- 02-2020 O DRAWN BY A. FONTAINE DESIGNED BY C. SHIFFLETT CHECKED BY C. SHIFFLETT SCALE 1"= 30' FT 7 J 0- W W J LL V a 0 Z J I W zz zu< w cn two LUmJ0- a O = LL U 0 > I- M 00 z Z SCALE 1"=30' JOB NO. 0 3lp 0' 60' 42932 SHEET NO. C4. 1 L 0 0 0 0 0 0 0 0 0 0 IN M ANCH RAILROAD y, 0 1 1 BUCK GHA BR 00 I I ' y39 ---- > o ° ° 0 0 o I I' EXTENTS OF 0 0 0 0 o I I O - J / FLOODPLAIN / / / / 0 0 0 ° ° ° ° ° 0 0 RAII-ROA NCH 0 /0 0 ° o C 0 M RA i i i\ 0 0 0 &INOHA BD'A------- - ' 0 0 00 ' I I BDr'K WIDTN R" - i i ' / 0 0 0 0 ° ° o // / I I i 8 ' / i ' 0 0 0 0 ' 1 / i o ° 24"HDPE I I - =' _ _ i' ' / ' o ° °% ° o / ' / %/ 0 INV=53588 I I TW 534.89' / 0 0 0 0/ 0 0°° 1.5'CONC. BLOCK BRIDGE ABUTMENT fX-2"BR/DG HEIGHTSIGN 24" HDPE o lNV= 537.13 0 0 I i 8: — SW529.72' 0 0 0 0/0 O o O ' /// / o - - _ - _ - _ o o / / - - 529. V'_ 0 -6- 0 ° / / // 000 - - -- -- 000000000°°'° / / --538 0 0 0 0-0 o-o 0 0-9 a o v o- o-v'*F 0-0-0 / 53 TW 529.1_41- — TW 529.68' / /- - - - - - - - - - - - — — — _ l lllll/l l l / TMP 58A2-21 W523.14' BIN523.68' / CRITICAL SLOPES, TYP. — — — — — l l 11 /lll/l//// ROGER L. GIBSON AND 533 — --- -- `- _ ---- — — — — — — — — — — — --- l /lll l//l STEPHENSON L. GIBSON Ji l l l/ l/ D.B. 1597, PG. 226 y35 _ — — — — - WL=BW5284 -_----------------- \-. 1/l D.B. 231, PG.585 TW 88'--__---------22- ------ \ rrll// ll/l l D.B.130,PG. 109 TIN BIN B 29.t0' —_ -- ———— — — — — —— lVtl = B4v a fs9 - ` - - 528.— ' — - - - --T- W-528.92'- y25 - --- - ------ ----- W52 30- BW-523-221 0) 523 N528:4II'_ _ --sz/_ ------ _ yti 522-BW5 2A4 - --_ - - - --- TW526.24' 52 1ryti_ ----,--521- g22 --- --- - - - BW523.05'TW 52 Illllllllhl) f).00' BIN 522 45' Tj2 - ` _ - - 525 — — \ \ I I I 1 I I 111ITW528. l l l I IIIIII E W522.3 III III I II 522 ---_ • 109 110 - - - - -- 521 - - - 108 52? _ _ /// < ' ;S22• / — _ \ ` _528 = = I I I 1 J l / \ 522. 00 \ TW = m ` \ B 522.03' FFETMP 58A2-20 \ f — — l , LENVIC, LLC PROPOSED 48" CMP PIPE D. B`3W, PG. 750 107 ® \ STORAGE FACILITY D. B.470, PG.09 -520 S2T, 140 L.F. D. B. 469, PG. 009 — \ 106 105 TMP 58A2-20A S27 JOSEPH W. RICHMOND, JR TRUSTEE D. B. 4992, PG. 686 113 D.B. 821, PG.218 51 103 I D.B. 268, PG.151 sum \ \ ` - - 10 2S' T OST8 IVt 114 s19 102 \ 1 O O 101 0 0 o OOGe` FPF\ \ `/ NF / N TOP=515.15 SO INLETIW G o INV. 1N=513.45 0/ 1F \ u CONNECTIOI 0 \ I N v INV. OUT=511. 0 15" HDPE PIPE (TYP.) \ s o i o O 0 00 1X.-10 % 000 O / O / ° O 0 0 o 0 O o // cf0 o o ° 0 0 0 ° q/ q EXTENTS OF o ° 0 0 24"CMP W/BROKEN o o // / ODYEAR FLOODPLA/N HEADWALL i o o INV. 511.Oa' ° O / 0 0 /I I/III -, I o o° o° o° 0 0 y^ IN 1II 515 0 0 ° / llb l II 0 0 0 0 / / I OOO O ° 0 . o O ° ° ° ° 0 0 0 0 0 0 0 O ° ° 0 0 ° O ° 0 0 .O ° O ° ° ° ° O . O 0 ° ° ° ° ° ° ° ° O 0 0E ° 0 0 0 PVC 0 ° JKNOWN o ° 24" CMP 0 0 ° 0 0 O 0 00 0 0 SCALE 1 "=20' 0 20' 40' e44 l.Tll Op',• 0 CLINT W. x: v S F LET Lie. N 51380 ? 10- 02-2020woo fy', G M E OUUN NC QOEo E w 3 wwQ LL 3 p LL w0m j V20 z w u O rn f n Lu a w 30V) x U) w0i c ry z OFva c U) ry W M Lu 00 0 x c 0p wL w HQ z ODATE 10- 02-2020 O DRAWN BY A. FONTAINE DESIGNED BY C. SHIFFLETT CHECKED BY C. SHIFFLETT SCALE i" = 20' 0 I^ Q Z V / zz J D Q Q J I I_ z z0 uzI- U w j 0 w LLI J Qv 0— LL JOB NO. 42932 SHEET NO. C5. 0 L 0 ofpLTHn 00 PRELIMINARY WATER QUANTITY ANALYSIS POINT 1 CLINT W. DRAINAGE AREA ANALYSIS (PRE -DEVELOPMENT) FLOW THROUGH PIPE STORAGE SYSTEM. V S FFL/E T > pv' i PRE -DEVELOPED ONSITE AREA FLOWS ROUTED THROUGH DETENTION o o 0 LicN S13S0 49 vs10- 02-2020 AREA = 0.65 ACRES Q (CFS) y; o o 0 0 010 G,,•, 0. 03 ACRES (MANAGED TURF) 10 YEAR 14.68 0 0. 19 ACRES (IMPERVIOUS) o 0 Tc = 9.7 MIN POST -DEVELOPED ONSITE AREA, UNDETAINED co AREA = 0.12 ACRES 0 0 0 o Q ( CFS) V (AC -FT) 0.00 ACRES (FORRESTED) 0 0 0 0 1 YEAR 0.83 0.037 0.09 ACRES (MANAGED TURF) 10 YEAR 2.80 0.03 ACRES (IMPERVIOUS) 0 o Tc = 6 MIN CALE°1" 100' E PRE - DEVELOPED OFFSITE AREA w " E N AREA = 4.17 ACRES Q (CFS) V (AC -FT) p 1 PRE -DEVELOPED OFFSITE AREA 0 0 0 ° H w 3 3 1.52 ACRES (FORRESTED) 1 YEAR 0.14 0.006 TOTAL: 4.17 AC 0 0 LL o 1. 14 ACRES ( MANAGED TURF) 10 YEAR 0.50 0 I WOODS: 1.52 AC 0 0o 0 U. wom IMPERVIOUS) 1.14 ACRES IMPERVIOUS o TURF: 1.50 AC 0 o 0 0uw L `^ a v m z Tc = 6 MIN POST -DEVELOPED OFFSITE AREA, UNDETAINED IMPERVIOUS: 1.14 AC o 0o " 0 w - u O AREA = 0.67 ACRES o CN = 71 o d o a Q ( CFS) V (AC -FT) 0.15 ACRES (FORRESTED) 0 Tc = 9.7 MIN. 0° o 0 o z Fir' v0- 1 YEAR 4.57 0.236 0.22 ACRES (MANAGED TURF) 0 0 0 03 0 N x 10 YEAR 15.94 0.30 ACRES (IMPERVIOUS) 0 0 d ix a LL u 0Tc= 6MIN 0 00 000 00 o c ry PRE - DEVELOPED COMBINED AT ANALYSIS POINT 1 0 0 0 ° v > m O Q ( CFS) V (AC -FT) Q (CFS) V (AC -FT) 0 0 0' v 1 YEAR 5.31 0.273 1 YEAR 1.25 0.055 0 0 o 0 0 00 0 rn 10 YEAR 18.52 10 YEAR 3.49 0 0 0 ° 0 0 DRAINAGE AREA ANALYSIS (POST -DEVELOPMENT) POST -DEVELOPED COMBINED FLOW AT ANALYSIS 0 0 0 0 0 0 co J H POINT 1 0 0 0 ° POST - DEVELOPED ONSITE AREA, DETAINED 0 o 0 AREA = 0.53 ACRES 0 (CFS) PRE -DEVELOPED ONSITE AREA 0 ° 0 0. 00 ACRES (FORRESTED) 1 YEAR 4.47 TOTAL: 0.65 AC o o 0 0. 08 ACRES (MANAGED TURF) 10 YEAR 18.50 o / ! g -- WOODS: 0.43 AC 0 0. 45 ACRES (IMPERVIOUS) TURF: 0.03 AC 0 0 ° Jo Tc = 6MIN IMPERVIOUS: 0.19 AC 000 0 0 CN= 71 ° 0 Q ( CFS) V (AC -FT) Tc = 6 MIN. 0° o 1 YEAR 1.90 0.090 0 0 0 10 YEAR 3.82 00 Lu a POST - DEVELOPED OFFSITE AREA, DETAINED 00 0 x O AREA = 3.50 ACRES 0 ° 0 0 O DATE 1.37 ACRES (FORRESTED) 0 0 \ 0° 0 ° 1. 39 ACRES (MANAGED TURF) 0 I 0 o 10- 02-2020 0. 74 ACRES (IMPERVIOUS) 0 00 0 0 Tc= 9.7MIN o o 0 I DRAWN BY Q ( CFS) V (AC -FT) 0 0 0 0 A. FONTAINE 1 YEAR 3.02 0.162 10 YEAR 11.98 0 ANALYSIS POINT ° 0 0 , O o DESIGNED BY 0 o' o 0 0 ° ° C. SHIFFLETT CHANNEL PROTECTION (ENERGY BALANCE): 0 0 CHECKED BY 0 0 0 0 Q ." DEVELOPED <- 080' ("/ RVWRE-DEVELOPEDONSITEPRE -DEVELOPED ON -SITE) /RV DEVELOPEDON -SITE +Q PRE -DEVELOPED OFF -SITE 0 0 C. SHIFFLETT PRE - DEVELOPED SCALE OK4.47 CFS <_ 0.80 ' (0.83 CFS " 0.037 AC -FT) / (0.090 AC -FT 0.006 AC -FT) + 4.57 CFS = 4.83 CFS q 0 00 000 000 0 1"=30' FLOOD PROTECTION: 0 o POST - DEVELOPED Quo <_ PRE -DEVELOPED QiD o OK 18.50 CFS <_ 18.52 CFS 0 0 0 o 0 0 TOP OF 48" STORAGE PIPE 0 ELEV. = 517.00 0 0 TOP OF WEIR 10 YEAR WSE 0 0 0 PLATE 516.10 516.95 0 o 0 10"x4" ORIFICE 0 CALE01" 00' INV 515.00 2YEAR WSE ui Z 516. 20010POST - DEVELOPED OFFSITE AREA, DETAINED 0 0° TOTAL: 3. 50 AC 0 0 Q V l Z J o WOODS: 1.37 AC o°° 0° o TURF: 1. 39 AC o° 0 0 J ( IMPERVIOUS: 0.74 AC o 'O 1YEAR WSE CN=68 00 Q > 515.14 Tc = 9.7 MIN. 0 o I --I 0 0 o v, POST -DEVELOPED OFFSITE AREA, UNDETAINED 0 0° 0 0 I -I z J TOTAL: 0. 67 AC o o o ° z O Q WOODS: 0.15 AC 0 ° TURF: 0.22 AC 0 ° 0 w IMPERVIOUS: 0.30 AC 0 0 ° o 1 STEEL PLATE CN= 77 Tc = 6 MIN. 1 1 o 00 Qww 0 0 wmU ELEV. 513.00 0 POST -DEVELOPED ONSITE AREA, DETAINED 0 o TOTAL: 0.53 AC 0 0 0 0 ° o ° 0 Q O Z O II 0/ Oi o / / ° - _..- WOODS: 0. 00 AC U 10" ORIFICE WITH TRASH o o- 0 RACK TURF: 0. 08 AC ° o 101- INV 513.00 a - _ _ IMPERVIOUS: 0.45 AC CN=92 J 00 SWM WEIR PLATE SECTION DETAIL Tc=6MIN. 0 0 y// II, JX1 POST -DEVELOPED ONSI10 TE AREA, UNDETAINED 0 0 TOTAL: 0.12 AC o 0 0 WOODS: 0.00 AC o d 0 TURF: 0. 09 AC 0 IMPERVIOUS: 0. 03 AC CN = 70 o o ° Tc= 6MIN. 0 ANALYSIS POINT O ° ° 0 : °" °. 0 0° o o° o 0 0 0 0 0 0 0 o n ° ° JOB NO. 42932 0 POST - DEVELOPED SHEET N0. 9 0 o C6.0 p00. 71 0L Nl.Tll pp'•• I%• i CAb CLINT W. x: rn S F LET A Lie. N 54380 ? 10-02-2020 fy', G M EOOUN N 0E a E 0, 110: DI-31B 6 it Throat W .Nca3 0 0 2 cn m o 0 o STA 12+93.97 w w 3 F Ln t o t o TOP 520.86 o w oo N ( 0 H- H- r. INV IN515.51(111) 0s6 o LuymLO N M m ai m N o , INV OUT 515.41 109 w V00 Oz+ DOS LO M LO m°0N F p OM LO UcornV Lo M ro+uiz,n ,+D r1 cn+H- c?+c,4 112:DI-1 a>ory C) Lo > z C] Q (L O cj p LO Z 0 p LO Z 0 STA 13+13.84 0 Lu wry a XHO» U)P- oH0> oF0>> TOP520.90 3G x 525 wcn ? ? Fz z Fz z INV OUT515.81 (111) 525 J a odLL U Q 7 i v ry Z Fv> O c U) om W M a o520520 w EXISTING GRADE PROPOSED 520 GRADE 520 EXISTING GRADE 515 515 7140 LF OF 510 48" CMP 510 INV. = 513 00 505 505 L