HomeMy WebLinkAboutSDP202000006 Correspondence 2020-10-07 (2)BOHLERI Albemarle County Department of Community Development 401 McIntire Road North Wing Charlottesville, VA 22902 Attn: Paty Saternye Re: Dear Ms. Saternye: 28 Blackwell Park Lane, Suite 201 Warrenton, VA 20186 o. 540.349.4500 October 7, 2020 Via Electronic Mail SDP202000006 Minor Site Plan Amendment — 3rd Review Response Chick-fil-A Store #1856 350 Woodbrook Drive Charlottesville, VA 22901 Albemarle, County BE #V166505 Bohler is pleased to submit on behalf of Chick-fil-A, Inc., the Minor Submission for the Chick-fil-A Store #1856. The following is our addressing comments received from various departments. Each cl responded to as follows: Planning Division — Brent W. Nelson, Paty Saternve Site Plan Amendment 41h comment response letter mment is addressed and Landscape Comment 4: [32.7.9.41 Revise Sheet C-1.0 Boundary & Partial Topographic Survey and Demolition Plan to show all required landscaping shown on the approved SDP 2006-90 Site Plan Amendment. Ensure species of all plantings are specified. A number of plants shown on that plan are not shown as existing in this proposed minor amendment. If approved plantings are no longer on site, show them as proposed with this site plan. Shrubs on the east and south sides of the building along with six trees (three along Rt 29 and three along Woodbrook Drive) are not shown as existing. Rev. 1: Comment not fully addressed. a) Address all ARB comments regarding previously approved landscaping not shown (see Comment 2, ARB letter dated May 22, 2020) Rev. 2: Comment not fully addressed. Address all ARB comments regarding previously approved landscaping not shown (see Comment 2, ARB letter dated August 25, 2020) Response 4: The ARB comments have been addressed. Please see comment response letter associated with the ARB resubmission. w . BohlerEngineering.com PatSat BOHLER �' Chick-f I -A Store #1856 Review onse Minor Site Plan 3�d Review Response October 7, 2020 Page 2 of 3 Lighting Comment 5: [32.6.2 (k)] Provide a photometric plan (including manufacturer's cutsheets) showing all light fixtures (existing and proposed) including fixtures under the canopies. Rev. 1: Comment not fully addressed. a) Revise the photometric plan to include a cutsheet for the proposed canopy lighting. The proposed fixture must be a full cutoff style fixture due to the number of proposed lumens. Rev. 2: Comment not yet addressed. Incorporate the manufacturer's cut sheet for each of the proposed light fixtures into the site plan. If the cut sheets cannot fit on the existing sheets, then a sheet should be added to the site plan. b) Revise the luminaire schedule to show a Light Loss Factor (LLF) of 1.0 for all fixtures to meet county requirements. Rev. 2: Comment not fully addressed. The Light Loss Factor (LLF) has been revised to 1.0 for most of the fixtures. However, CRUS-1 & CRUS-2 still have LLFs of less than 1.0. Revise the luminaire schedule to show a LLFs of 1.0 for all fixtures to meet county requirements. Response 5: The photometric plan has been revised to reflect the updated luminaire schedule and LLF. Please see sheet E1.5-E1.7. Comment 7: Address all comments provided by other members of the Site Review Committee. Rev. 1: Address all outstanding comments from ARB and ACSA reviewers Rev. 2: Comment not fully addressed. Address all outstanding comments from ARB and ACSA reviewers Response 7: Acknowledged. Albemarle County Service Authority (ACSA) — Richard Nelson Comment 2: The existing domestic meter is 1.5" with a 1.5" meter vault. This will need to be relocated outside of the proposed concrete. Response 2: The label has been revised to read "Relocated 1.5" WM and Meter Vault". Please see sheet PS1.0. Comment 3: The existing irrigation meter is located in the same island as the domestic meter. This will need to be relocated as well. Response 3: The existing irrigation meter has been relocated to the same island as the domestic meter. Please see sheet PS1.0. Comment 1: Add note that the contractor is to contact the ACSA 3 business days prior to making the new service connection to the existing ACSA water main, to schedule an inspector to be on site. Response 1: A note to the contractor has been added at the ACSA water main tap location. Please see sheet PS1.0. w . BohlerEngineering.com BOHLER// Paty Saternye Chick-f I -A Store #1856 Minor Site Plan To Review Response October 7, 2020 Page 3 of 3 Should you have any questions regarding this project or require additional information, please do not hesitate to contact me at (540) 349-4500. Sincerely, Bohler Engineering VA, LLC C. Wright, P.E. JCW/jb H:\16\V166505�Administrative\Letters\201007 Minor Site Plan Amendment 3rd Review CRL .doc www. BohlerEngineering.com