The County of Albemarle Planning Division will grant or recommend approval of the Minor
Amendment referenced above once the following comments have been addressed: [Each
comment is preceded by the applicable reference, which is to the Zoning Ordinance otherwise
specified.]
Planning
Rev 3 Comments:
1. , , u upuated landscaping plan says that there is the same number of plants, however
the new plan shows 86, and the previous shows 77. Please clarify.
a. REV 4: Addressed. New plan shows 93 plants, which is greater than the
requirement. Therefore, the requirement has been met.
2. Forth
,e canopy calculations
a. REV 4: Addressed. New plan shows a greater canopy calculation than the
original site plan. Therefore, the requirement has been met.
Rev 2 Comments:
1. Easements and deeds.
a. J1IUVV Ll IC �UcU Gook and Page Number for all existing easements. There are two
DB/PG for the 20' private drainage easement (4886/660 and 4732/678) which do
not appear to both be shown but were shown on previous submissions.
i. Addressed.
b. Sign easement: Is an easement needed for the proposed sign on Cascadia's open
space? Or is this already covered under Cascadia's covenants/maintenance? If an
easement is needed, it must be shown on an easement plat.
i. Addressed.
c. Clarify what 'adjusting' the 20' private drainage easement means. If the
easement is being moved, then the existing easement plat must be amended.
Any non-ACSA easement that is new or being revised must be shown on an
easemer
Addressed. Applicant clarified easement is not being adjusted.
d. A letter is needed from the owner (Towne District LLC) of TMP 78H-01-A
agreeing to the construction easements. Please include with the resubmittal.
i. REV 3: Not addressed. The letter says that the agreement is theoretical,
and not yet finalized. The letter needs to have the property owner fully
agreeing to the proposed off -site easements. Each easement (as shown
on the site plan) also needs to be specifically named in the letter.
ii. REV 4: Not addressed. Applicant states letter is forthcoming.
2. Include the maximum neigni o, u, an retaining waus ii i� a,umum neignt is only
listed for some, not all).
a. REV 3: Not addressed. Include on the site plan the maximum height for all
retaining walls that are labeled. Only some show a maximum height.
b. REV 4: Addressed.
3. Add note to SP5 that: "any luminaire fixture over 3,000 lumens shall be a full cutoff
luminaire."
a. Addressed.
4. SP1 lists SP5 as lighting plan adjustment to landscaping plan- please clarify (should this
just say 'lighting plan')? Also, SP6 is mislabeled as a second SP5 on the bottom right
corner.
a. Addressed.
5. All owners are not listed on SP2. The owner of record for TMP 78GH-01-267 is Virendra
and Nita Patel, according to the County's GIS. The owner for TMP 78H-01-A is Towne
District LLC.
a. Addressed.
6. Include in the Zoning note on SP2 that these parcels are in the Entrance Corridor.
a. Addressed.
Rev 1 Comments:
1. [Comment] Sheet 1 lists the office building as having one story, while Sheet 3 lists of the
office building has having three stories. Please clarify the total square footage of the
building and the number of stories of the building.
a. Not fully addressed. Now listed as two-story building on basement and 8,465
square feet, however some areas list as 8,500 square feet. Please consistently
label as 8,465 square feet.
b. Addressed.
2. [Comment] On Sheet 2, provide a table showing the open space calculations for all
Blocks, so that Planning Staff may determine if open space requirements are being met.
a. Addressed.
3. [Cascadia Code of Development] Loading spaces. According to Cascadia's COD, the
number of loading spaces is "based on the total non-residential gross leasable within
Block 1 and not upon a gross leasable square footage per lot basis." The proposed 8,500
square foot office is the only commercial (non-residential) use in Block 1. Therefore, one
(1) loading space is required, based on the COD's requirement of "one (1) space for the
first 8,000 square feet of non-residential gross leasable area". Please modify the site
plan to show this loading space.
a. Addressed.
4. [Cascadia Code of Development] Dumpsters. According to Cascadia's COD, the number
of dumpsters is also "based on the total non-residential leasable square footage within
Block land not upon a per lot basis. Dumpsters shall be provided on the basis of one (1)
dumpster pad, which does not impede any required parking or loading spaces, nor any
pedestrian or vehicular circulation aisles, for every four thousand (4,000) gross square
feet of non-residential building within Block 1". Since this is the only commercial use in
Block 1, please provide two (2) dumpsters to meet the COD requirement, as the gross
non-residential square footage would be 8,500.
a. Addressed.
5. [4.12.13 (e)] Loading areas and dumpsters. The dumpster pad shown on the site plan is
impeding access to one of the parking spaces. Relocate dumpster to meet 4.12.13(e)
requirement that "dumpster pad that does not impede any required parking or loading
spaces, nor any pedestrian or vehicular circulation aisles". Show that the dumpster pad
material will be concrete.
a. Addressed.
6. [4.12.6 and Cascadia Code of Development] Minimum number of parking spaces. The
parking tabulations on the site plan and Section 4.12.6 indicate that the site should have
34 parking spaces, however only 33 are shown on the site plan. Revise the site plan to
show the additional parking space.
a. Not fully addressed. Please label the 34" space (parallel space) as 'parking
space' to be clear. Must be striped as a parking space. Sufficient parking is now
provided.
b. Addressed.
[4.12.16] Minimum design requirements and improvements for parking spaces within
parking areas and parking bays. For the parking spaces that have a reduced length of 16
feet (versus the standard 18 feet), revise plan to show that there will be sufficient
overhang in the areas where the parking spaces abut the planting median and the
planting areas with small shrubs. A 2-foot overhang is required. Some of the shrubs may
need to be removed or the type changed in order to accommodate the 2-foot overhang.
a. Not addressed. Remove plants (small shrubs) or move them further back along
the upper portion of the row of 7 parking spaces (in front of the trees labeled
RL-11 and RL-10) that conflict with the two -foot overhang. These plants are not
required and should not be shown on the site plan or need to be moved out of
the 2' overhang line.
i. The shrubs in the lower row of 10 parking spaces in front of the 6'
landscape easement are acceptable and are not in the overhang.
ii. Addressed.
8. [4.12.15(g)] Pedestrian access. Provide pedestrian access, in the form of a concrete
sidewalk (at least 5-feet, per COD standards) to connect the sidewalk along Cascadia
Drive with the proposed 6-foot concrete sidewalk along the front of the proposed office
building.
a. Addressed.
9. [32.7.9.7] Landscaping and screening. On the original site plan (SDP201400075), 12
evergreen type trees are shown in the landscape easement between the parking lot and
the residential units behind the parking lot. Indicate if both the 25 shrubs and 12
evergreen trees will between the parking lot and residential units. If the evergreen trees
are still being provided, the shrubs are not needed in addition, allowing for more
ov= -hicles in the 16-foot long parking spaces.
a. Addressed.
Inspections (Michael Dellinger)
1. Ketaining wails greater than 3 feet in height require a separate building permit. Walls
exceeding 4 feet in height require a stamped engineered design also.
a. REV 2: Not fully addressed: Please add following language (not just noting):
"building permits required for retaining walls" Otherwise no objection.
(3/15/2019)
b. REV 3: No Objection.
2. Parking spaces and access isles shall not have a surface slope greater than 1:48. Access
isles sh '- - -` `'- - same level as the parking space they serve.
a Addressed.
ARB (Margaret Maliszewski)
REV 3: Approved by ARB on 08/15/2019.
1. EC guidelines require that retaining walls 6' high and taller be terraced and planted.
Please revise the plan accordingly.
2. A note on the plan indicates that plant counts haven't changed. For each plant that has
been moved, please identify approved location and proposed relocation.
3. The building shown on the plan has not been approved by the ARB. Either: 1) remove
the footprint from the plan; OR 2) provide architectural drawings for ARB review; OR 3)
include the note on the drawing that was previously provided: "NOT INCLUDED IN ARB-
2015-05" (see below). Note that ARB review of the building is required. It is
recommended that an ARB submittal be made as soon as possible.
Fire Rescue (Shawn Maddox)
1. Thank you for addressing the previous comments. Fire Rescue has no objections to the
plans as submitted. SNM (3/19/2019)
2. What will the height of the building be? If over 30' then the travel way must increase to
2F'
a. Addressed
3. The iravei way exceeds 150' so a turnaround or additional exit is required.
a. Addressed
4. Is the building to be sprinklered? If so then a FDC must be shown and it must be located
within 100' of a fire hydrant.
a. Addressed
5. A knox box will be required for the building. Please add a note to the plan showing the
requirement and that the location can be coordinated with the fire marshal's office.
a. Addressed
ACSA (Richard Nelson)
Add note that ACSA is to be notified 3 days prior to fire hydrant relocation to get an
inspector on site.
a. Addressed.
2. Add details TD-3 and TD-8 from the General Water and Sewer Construction
Specifications.
a. Addressed.
3. REV 3: There is an existing water meter setter to serve the property. It appears the
storm along Cascadia Drive is on top of it. This meter should be used for domestic use
or irrigation. If not used it will need to be abandoned.
a. Addressed.
4. REV 3: If the existing meter setter is not used for domestic use, move the domestic
meter in the grass area by the proposed fire hydrant.
a. Addressed.
5. REV 3: Move the Tire line gate valve after the fire hydrant tee. This will indicate the end
of ACSA ownership.
a. Addressed.
6. REV 3: Provide fixture counts if domestic use of the existing meter setter is explored, to
confirm if the size is adequate.
Addressed.
7. REV 4: Add note to have contractor contact ACSA 3 days prior to the hydrant relocation
and meter abandonment, to coordinate an inspector to be on site.
Engineering (Matt Wentland)
1. No Objection (03/15/2019)