HomeMy WebLinkAboutSP202000015 Traffic Study 2020-10-19SHIMP ENGINEERING, P.C.
Design Focused Engineering
October19,2020
Mr. Adam Moore, P.E.
Virginia Department of Transportation
701 VDOT Way
Charlottesville, VA 22911
RE: Preliminary Turn Lane Analysis SP2020-15 Animal Wellness Center TMP 56A2-01-00-7
Mr. Moore,
Please find enclosed a right and left turn lane warrant analysis for Animal Wellness Center, located on
Route 240 (Crozet Avenue). The enclosed analysis is based off a long-term proposed build -out on the site
and is meant to be preliminary in nature; turn lane warrants will be presented to you concurrent with site
plan submittal and will be more precise in nature once the specifics of the proposed veterinary expansion
are finalized.
The following items are included with this report:
VDOT 2019 Traffic Data
ITE Trip Generation (I& Edition) Summary
Warrant Analysis Exhibit
Our analysis shows that a right -turn taper and a left turn lane are not warranted for this project.
If you have any questions you may contact me atjustin@shimp-engineering.com or by phone at 434-953-
6116.
Best Regards,
Justin Shimp
Shimp Engineering, P.C.
912 E. High St. Charlottesville, VA 22902 1434.227.5140 1 shimp-engineering.com
Future Build -Out Preliminary Analysis: 12,000 SF Veterinary Office
1. VDOT 2019 Traffic Data
Speed Limit 25 MPH
ROUTE 240 Crozet Avenue
1.43 mi segment between US 250 Rockfish Gap Turnpike and
02-819; Three Notchd Rd
K 0.0965
D 0.5564
AADT 7900
Peak Hour Total 762
Peak Hour Approach (Direction A) 424
Above is the VDOT 2019 traffic data which was used to determine the peak hour trips in each
direction. It was assumed that the majority of morning trips would be heading south along Crozet
Avenue in the morning to get to Rt. 250, while the majority of evening trips would be heading
north back from Rt. 250. Both the left -in and right -in movements for this use were greatest in the
morning and so the warrant analyses were based on morning traffic patterns. This assumption was
used in conjunction with ITE Trip Generation information to create the estimate of right and left
turns into the site. Please see the table below.
2. ITE Trip Generation (IW' Edition) Summary
Trip Gen Manual, 30th Ed
AM
I PM
Use Description
I ITE
JQty
in
out
Total
in
out
Total
0
0
0
0
0
0
Veterinary
1 64012000sf
29
15
44
17
25
42
Total
29
44
17
42
Right Turn
16
7
LeftTurn
13
9
3. Warrant Analysis Exhibit
For the right turn warrant analysis, the morning situation was analyzed as it had the highest
advancing volume of traffic. With 16 right turns and an approach total of 441 vehicles, a right
turn taper is not warranted.
16
441
PKV APPROACH TOTAL. VE,w. PER YOUR
F-79
Appropriate Radius required at all Intersections and Entrances (Commercial or Private).
LEGEND
PHV - Peak Hour Volume (also Design Hourly Volume equivalent)
Adjustment for Right Turns
For posted speeds at or under 45 mph. PHV right turns > 40. and
PHV total < 300.
Adjusted right turns = PHV Right Turns - 20
If PHV is not known use formula- PHV = ADT x K x D
K = the percent of AADT occurring in the peak hour
D = the percent of traffic in the peak direction of flow
Note An average of 1 1% for K x D will suffice
When night turn facilities are warranted, see Figure 3-1 for design criteria. -
FIGURE 3-26 WARRANTS FOR RIGHT TURN TREATMENT (2-LANE HIGHWAY)
Rev. 1/15
For the left turn warrant analysis, the morning situation was analyzed as it had the highest left
turns into the site, when compared with the evening movement and the highest percent left turns
when compared to the evening movement. With 13 left turns into the site and an advancing
volume of 351 vehicles, a left turn lane is not warranted. Table 3-1 is applicable to a 40 mph
minimum design speed; at a speed limit of 25 mph, the thresholds warranted a turn lane in this
location may be higher.
Warrants for Left Turn Storage Lanes on Two -Lane Highways
Advancing volume and opposing volumes (VPH), speed and percent left turns are used
to determine whether a left turn storage lane is warranted on two-lane highways
The warrants in table below are taken from the 2011 AASHTO Green Book, Chapter 9.
Section 9.7 3, Page 9-132. Table 9-23. They were derived from Highway Research
Report No 211. Figures 2 through 19. for required storage length delemnnat ons-
WARRANTS FOR LEFT TURN LANES ON TWO-LANE HIGHWAYS
vPH
ADVAN004 VOLL"
OPPD503
VOLUM
5% 10% 20% 30%
1arnPaa7 U!rrrveo UWrnauclarn
40WH DESIGN SPEW
9W
330
240
190
150
000
410
305
225
1
200
400
510
no
275
245
200
040
470
350
305
100
720
515
390
340
504ff" DESIGN SPEED'
Sao
280
210
165
135
000
350
290
105
170
400
430
320
240
210
200
500
400
1
300
270
1o0
015
440
335
205
004in DESIGN SPEED'
$00
230
170
12e
115
000
290
210
100
140
400
305
270
1
200
175
1
200
450
330
250
215
100
506
370
275
240
TABLE 3-1
Source. Adapted from 2011 AASHTO
Green Book, Chapter 9. Section 9.7.3,
Page 9-132, Table 9-23
aPv9w
vONritA10
4F
NrvAYhG urr^
r0N4l MN 19tu1 "
Example -
Two -lane highway with 40-MPH
operabrg speed
Opposing Volume (VPH) - 600
Advancing Volume (VPH) - 440
Lek-Tum Volume (VPH) - 44 or 10% of
Advancing Volume
With opposing volume (VPH) of 600 and
10% of advancing volume (VPH) making
left turns, and advancing volume (VPH)
of 305 or more will warrant a left -turn
lane
USE DESIGN SPEED IF AVAILABLE. When the Average Running Speed on
IF NOT USE LEGAL SPEED LIMIT an existing facility is available, the
corresponding Design Speed may be
obtained from Appendix A, Section A-1.
Rev. 7114
Conclusions:
Right and left turn lanes are not warranted for a 12,000 SF veterinary office in this location. This
preliminary analysis is provided for informational purposes. Once a site plan is submitted to the County
for review, a more specific turn lane analysis will be provided to VDOT.