HomeMy WebLinkAboutSDP202000052 Study Traffic Study 2020-06-10SHIMP ENGINEERING, P.C.
Design Focused Engineering
Warrant Analysis
Albemarle County TMPs 75-66 & 76-17
Regents School of Charlottesville
June 10, 2020
912 E. High St. Charlottesville, VA 22902 1434.227.5140 1 shimp-engineering.com
Contents:
1. Project Narrative
2. Trip Generation & Distribution
3. Warrant Analysis
4. Conclusion
1. Project Narrative
The proposed entrance is located on the southern side of State Route 702 Reservoir Road in Albemarle
County. This entrance is to serve a private school with enrollment of maximum 468 students; therefore
the analysis of this entrance assumes maximum enrollment. Please note that the current site plan proposes
280 students, so trip generation figures may differ from the site plan. This analysis uses trip generation
estimates from ITE 10`h Edition Trip Generation software to be conservative and is separate from the
traffic study submitted for the operational changes request. For more detailed trip generation data, please
refer to the October 12, 2018 analysis by EPR, P.C.
Both left and right turn lane warrant analyses were conducted, and neither were found to be required for
this project. Two key assumptions were made for these analyses:
1. A direction factor of 0.5 was assumed for the regular traffic (unrelated to the school) that exists
on Reservoir Road.
2. A direction factor of 0.95 was assumed for traffic related to the school. This direction factor was
assumed for traffic traveling towards the school in both the morning and the evening conditions.
Reservoir Road is a dead end road with very few residences located west of the site. Our direction factor
for school traffic assumes that most of the travel will be to and from Route 29.
2. Trip Generation & Distribution
The turns into and out of the site were analyzed based on the 1 Oh Edition ITE Trip Generation estimates
for a private school (K-12) with 468 students. Pairing this information with the assumed direction factor
of 0.95 for school traffic produces the information found in Table 1 below.
Table 1. ITE Trip Generation Summary
ITE TripGen, 10th
Edition AM PM
Use Description ITE Qty in out Total in out Total
Private School (K-12) 536
468
Students 228 146 374 34 46 80
Right Turn 11 2
Left Turn 217 33
The following figures are taken directly from the ITE Trip Generation web -based App, where we received
data for trips into and out of the site.
goEry Finer
l Trip Gen Manual, 19tlr Ed
dIt, e 111 Is available. Clidr hem ig upgrade. SEARCH
BY — USE LODE: 536
0 IAXR
USE GROUP: 50O-
599)Inslitugonal 536-
private School (K-12) LAXU
USE SUBCATEGORY: All
SRes INDEFEDIDENT
VARIJUBLE Irvh Students
IW—
W.y. Ft A Hour of Adjacent Street TralPX SETT
WILOCATION: General
DrbaNSuburban Vehicle
E468R
Iv vnwE To cA Calwlale,
Data
Plot and Equation Caution - Smarr Sample Srze w
3so F
I,
3OD
X
study Site Figure
1. ITE Trip Generation AM Peak Hour 900
450 X =
Number of Students Rese[
Zoom Res[ore Fitted
Curve soo
Average
Rate DATA
STATISTICS Private
School (K-12) (536) Click rgr mgrI details IntlepentleM
Venable: studen
nine
Period: Weekbey
Peak
Hour M AdJaee.t Street Tmfie One
It— Between T OUT 9 a m SeWnglLoragon:
Uenerel
lJrben E—rean Tnp
Type: Vehicle
Number
of Studies: 4
Avg.
Num. of Students'. 5Dfi
Average
Re. 0.
80 Range
of Rates: 049-
096 Standard
Deviation'. 021
IF
Curve Equation: T =
g.eotx)- 3.5T Ra
063
heed—
Dtstrmugon: 61%
entering 39%eniing Calculated
Trig, Ends: Avenge
Rnte: 374(TMeI), 228 U,17 ,1W Ui PiXed
Cu-: 371 (Trial), 226 (Erlhy), 145 (aft)
Query Filter
Trip Gen Manual, 101, Ed
Nely dal. edum i5 available Cllck hen: to upgrade.
S536cR ev uNo ®coDE.
50 g-699)Ins[dutional vl
536- Private Srdlodl (K-12)
USE SVBOATEGOM
All Sites
p—NDE LE W:
SWdelds
Weekday, Peak Hour of AtlI .. Street TralNr
s
General Udtard&bulban
Veh cle
EdfipR IV VALUE To taCaluiate IP
Data Plot and Equation caution- S—Ij samp)a size
X
loc
X
50
pD __20D_______________40O ____
L__________
600 ______
X = Numb—f 5tudents
Reset Zoom Resmre
X Study Site
Figure 2. ITE Trip Generation PM Peak Hour
Avuage Rate
DATA STATISTICS
d Use:
Pdvale School (K-12) (536) CI Iuk for more tlelalle
ndependent Mdable:
Students
Tme Period:
Weekday
Peak Hour of Mj....t Bbee1 Tmigc
One Hour Between 4 and 6 pm.
SeltinglL—b":
General 11NaNSubulban
Tnv Tyve:
Vehlde
Number of SW dies:
3
Avg. Num. of SWdenis:
581
Average R-
R - of Rates:
013-02a
Standard Deviatlnn.
p06
Filled Cume Equation:
Not Glven
Rv'
Direcdonal pistribuppn:
43% enledng, 57% a,iting
CaInuIWLV Trip Ends:
Average Rale'. 80 (Total). 34 (Erdry). 16 (Exu)
3. Warrant Analysis
A right and left turn warrant analysis was performed for the proposed entrance using the trip generation
information from the previous section in conjunction with VDOT 2018 Traffic Data. Please see the table
below for the traffic data for State Route 702 Reservoir Road.
Table 2. VDOT 2018 Traffic Data
Reservoir Road
35 mph
1.7 mi section from 0.5 ME Dead end
and 2.20 ME Dead End
K
D Assumed .5
AADT 400
Peak Hour Approaching 44
Note: K*D assumed 11%
The right turns into the site are highest in the morning, with 11 trips. This traffic generated by the
proposed school is added to the peak hour approach total for the right turn lane warrant analysis. Please
see Figure 3 below for the results of the right turn lane warrant analysis.
120
1 ''.}},• {{ ••'}} ;•; FULL —WIDTH TURN LANE AND TAPER FIEF MM
tiff =''•' ==.. _
Lij -':.}}'+';+;'}.{{:f}}{r{W};:}}}*,:,fir,•.
i
s
60 •TAPER REQLa1RED+ -
y:;:•}:tip:•.
ZE
CL---------------------
20
1 Q TUFEN L NT S --------------- OR
TAPERS REQUIRED 11
55
I100 200 S00 400 Soo Soo 700 1
PHV
APPROACH TOTAL, VEHICLES PER HOUR Appropriate
Radius required at all Intersections and Entrances (Commercial or Private)- PHV -
Peak Hour Volume (also Design Hourly VoIume equivalent) Adjustment
for Right Turns Far
posted speeds at or under 45 mph, PHV right turns > 40, and PHV
fatal < 300- Adjusted
right turns = P h V Right Turns - 20 If
PHV is not known use formula: PHV = ADT x K x D K =
the percent of AADT occurring in the peak hour D =
the percent of traffic in the peak direction of flow Note:
An average of 11% for K x D will suffice. When
right turn facilities are warranted, see Figure 3-1 for design criteria FIGURE
3-26 WARRANTS FOR RIGHT TURN TREATMENT (2-LANE HIGHWAY) Figure
3. Warrant for Right Turn Taper Figure
3 shows that no right turn lane or taper is warranted for this site.
For the left turn lane warrant analysis, the traffic generated by the proposed school is added to advancing
and opposing volumes. The direction factor of baseline traffic on Reservoir Road is assumed to be 0.5,
therefore the baseline peak hour advancing volume is equal to the peak hour opposing volume. Morning
left turns were analyzed as this scenario produces the most trips with a total of 217 left turns into the site.
This traffic added to the baseline peak hour of 44 trips gives an advancing volume of 261 (left turns
comprise 43% of advancing volume). Morning right turns into the site plus the baseline traffic gives an
opposing volume of 55 trips. Please see Figure 4 below for the left turn taper warrant.
F-58
Warrants for Left Turn Storage Lanes on Two -Lune Highways
Advancing volume and opposing volumes (VPH), speed and percent left turns are used
to determine whethera left turn storage lane is warranted on two-lane highways_
The warrants in table below are taken from the 2011 AAS HTO Green Book, Chapter 9,
Section 9.7.3, Page 9-132, Table 9-23. They were derived from Highway Research
Report No. 211, Figures 2 through 19, for required storage length determinations.
WARRANTS FOR LEFT TURN LANES ON TWO-LANE HIGHWAYS
VPH
ADVANCING VOLUME
OPPOSING
VOLUME 5%6 10%6 20% 311%
LEFT TURNS LEFTTiIRIG LEFT TURNS LEFT TURNS
40-MPH DESIGN SPEED'
BOD 33D 240 ia0 100
601) 41D 305 225 200
40D 51D 380 275 245
201) 54D 470 350 305
101) 72D 515 390 34U
54MPH DESIGN SPEED'
BOD 28D 210 165 1W
00D 35D 280 195 170
401) 43D 320 240 210
201) 55D 4110 300 270
10D 015 445 335 295
94MPH DESIGN SPEED'
80D 23D 170 125 115
1001) 29D 210 1100 140
401) 365 270 2110 175
20D 45D 330 250 215
101) 505 370 275 240
TABLE 3-1
Source: Adapted from 2011 AAHTO
Green Book, Chapter 9, Section 9.7.3,
Page 9-132, Table 9-23
USE DESIGN SPEED IF AVAILABLE,
IF NOT USE LEGAL SPEED LIMIT.
Figure 4. Warrant for Left Turn Taper
OPKINNG
k ytlLLYE1VPFl)
AD' CIHG HT7X1RN
x+i4L4 P FU vOLuAEP+'W
Example -
Two -lane highway with 40-MPH
operating speed
opposing Volume (VPH) - 600
Advancing Volume (VPH) -440
Left -Turn Volume (VPH) - 44 or 10% of
Advancing Volume
With opposing volume (VPH) of 600 and
10 of advancing volume (VPH) making
left turns, and advancing volume (VPH)
of 305 or more will warrant a left -turn
lane_
When the Average Running Speed on
an existing facility is available, the
corresponding Design Speed may be
obtained from Appendix A, Section A-1.
Advancing volume does not exceed 340 vehicles per hour, therefore a left turn taper is not warranted.
4. Conclusion
Enrollment for Regents School at Reservoir Road is only permitted to reach a maximum of 468 students.
Based on ITE Trip Generation, 10th Edition figures for this site in combination with VDOT 2018 Traffic
Data for existing traffic on Reservoir Road, neither a right taper/turn lane nor left turn lane is warranted
for this site.
Please contact me with any questions or comments at (434)227-5140 or justin(&shimp-en ing eerieg com.
Regards,
Justin Shimp, PE