HomeMy WebLinkAboutZMA201900010 Plan - Approved 2020-10-22ederil.Storaye
Sentara.Martha I IF f n 4V
a
Outpatient Care Center...
ve
SITE71
• � _ • otfit Rd'
` Walgreens
t �� " i •
UGHT310yaE F , ,,�• �� !
1 CHARLOTTE. LE= ` !
• Christi pl Chu h' �iBan rd Steve
y
® Bgght Beginnings
`-
i %eschAb
ool e
1 qn! I
t
F
Co1xwY t•n•
Google '
NTS,
1
4 i .�
ST = y
Q
gy' ,
$ A e•a!
f -
��•�
_ Q�
, ~'.
b .
a
1
r 6=9 Gcade. Nan dra 1111211l9C-=-= -
OYA PM
ZONING MAP AMENDMENT
CONCEPT PLAN
ZMA201900010
OWNER/DEVELOPER
Albemarle Land Development LLC
1949 Northside Dr
Charlottesville, VA 22911
PROPERTY ADDRESS
3223 Proffit Rd
Charlottesville, VA 22911
MAGISTERIAL DISTRICT
Rivanna
STEEP SLOPES £s STREAM BUFFER
The project area contains areas of managed slopes. There are
no stream buffers within the project area.
SOURCE OF BOUNDARY AND
TOPOGRAPHY
Boundary and topographic survey for property provided by:
Roger W. Ray & Associates, Inc. April 15, 2019
Boundary and topographic information for adjacent parcels
compiled from the Albemarle County Office of Geographic
Data Services GIS Data.
F LOODZON E
According to the FEMA Flood Insurance Rate Map, effective
date February 4, 2005 (Community Panel 51003CO286D),
this property does not lie within a Zone A 100-year flood
plain.
WATER SUPPLY WATERSHED
Non -Watershed Supply Watershed
WATER AND SANITARY SERVICES
Provided by Albemarle County Service Authority (ACSA)
PARKING
All parking shall comply with Sec. 4.12 of the Albemarle
County Zoning Ordinance
USE
EXISTING: Single -Family Residential
COMPREHENSIVE PLAN: Urban Density Residential
PROPOSED: R15 - Residential
ZONING
EXISTING: R15 - Residential, Airport Impact Area (AIA)
Overlay, Steep Slopes - Managed Overlay
PROPOSED: R15
SIGNS
All signs and pavement markings shall conform with the
latest edition of the MUTCD Guidelines.
ACREAGE
TOTAL: 7.29 AC
PROPOSED UNITS
Maximum 80 units. Maximum gross and net density of 11
dwelling units per acre.
OPEN SPACE + RECREATION
REQUIREMENTS
Open space area shall be provided in accordance with Sec. 4.7
of the Albemarle County Zoning Ordinance. The proposed
open space area shall be privately owned. A minimum of 25%
of the site shall be designated as open space.
Recreational areas and facilities shall be provided in
accordance with Sec. 4.16 of the Albemarle County Zoning
Ordinance.
3223 P RO F F I T ROAD
SITE & ZMA DETAILS
Sheet 2 of 7
USE TABLE
BLOCK
BLOCK
BLOCK
TOTAL
ALLOWED USES
All uses listed under section 18.2.1 of the Albemarle
All uses listed under Section 18.2.1 of the Albemarle
County Zoning Ordinance will be permitted by right
County Zoning Ordinance will be permitted by right
within Block A. All uses listed under Section 18.2.2
within Block B. All uses listed under Section 18.2.2 of the
of the Albemarle County Zoning Ordinance will be
Albemarle County Zoning Ordinance will be permitted
permitted through approval of a special use permit
through approval of a special use permit within Block B.
within Block A.
MAXIMUM BUILDING HEIGHT
4574-Stories whichever is less
45'/4-Stories whichever is less
SETBACKS
FRONT MINIMUM: 5' from Right-of-way
FRONT MINIMUM: 5' from Right-of-way
FRONT MAXIMUM: 25' from Right-of-way
FRONT MAXIMUM: 25' from Right-of-way
SIDE: 5' feet, unless the building shares a common wall;
SIDE: 5' feet, unless the building shares a common wall;
provided that (a) in the R-10 and R-15 districts if the
provided that (a) m the R-10 and R-15 districts if the
abutting lot is zoned residential other than R-10 and
abutting lot is zoned residential other than R-10 and
R-15, Rural Areas, or the Monticello Historic district,
R-15, Rural Areas, or the Monticello Historic district,
MY dwelling unit that exceeds 35 feet in height shall be
any dwelling unit that exceeds 35 feet in height shall be
set back five feet plus one foot for each foot the dwelling
set back five feet plus one foot for each foot the dwelling
unit exceeds 35 feet in height; and (b) any minimum
unit exceeds 35 feet in height; and (b) any minimum
side setback otherwise required by this section may be
side setback otherwise required by this section may be
reduced in accordance with section 4.11.3
reduced in accordance with section 4.11.3
REAR 20'
REAR: 20'
FRONT STEPBACKS
For each story that begins above 40 feet in height or for
For each story that begins above 40 feet m height or for
each story above the third story, whichever is less, the
each story above the third story, whichever is less, the
minimum stepback shall be 15 feet
minimum stepback shall be 15 feet
DRIVEWAY STANDARDS AND
Single-family attached and single-family detached
Single-family attached and single-family detached units
GARAGE SETBACKS
units in Block A, Area 1 on Sheet 4 shall be subject
located outside of Block A, Area 1, on Sheet 4 shall be
to the following: driveways shall be rear -loaded and
subject to the following front -loading garages shall be
only enter onto internal `Road B' Block A Area 1'may
setback a minimum of 3 feet from the building facade of
permit double frontage lots without screening or with
which the garage is located or porch/deck on the facade
a modification to screening of double frontage lots
of which the garage is located.
required by 32.7.9.7, as permitted by the agent. Waivers
and/or exceptions from the prohibition of double
frontage lots and screening of double frontage lots may
be pursued during site plan or subdivision plat.
Single-family attached and single-family detached units
located outside of Block A, Area 1, on Sheet 4 shall be
subject to the following: front -loading garages shall be
setback a minimum of 3 feet from the building facade of
which the garage is located or porch/deck on the facade
of which the garage is located.
GARAGE MAXIMUM: None
GARAGE MAXIMUM: None
PROPOSED AREA OF BLOCK
5.2 AC
2.09 AC
7.29 AC
MINIMUM NUMBER OF
44
0
44
DWELLING UNITS
MINIMUM DENSITY BASED UPON
9 DUA
0 DUA
6 DUA
AREA
MAXIMUM NUMBER OF
80
30
80*
DWELLING UNITS
MAXIMUM DENSITY BASED UPON
16 DUA
15 DUA
11 DUA
AREA
1
*Total number of dwelling units in the development not to exceed 80
TMP 32-A-02-2
Submitted 17 June 2019 Revised 23 July 2020 project: 19.029
Revised 11 March 2020 Revised 10 August 2020
Revised 12 May 2020 REVISED 08 SEPTEMBER 2020 SHIMP ENGINEERING, P.C.
80 0 80 160 240
(D
Graphic Scale: 1"=80'
ZONING MAP AMENDMENT
CONCEPT PLAN
Z MA201900010
3223 P RO F F I T ROAD
BLOCK PLAN
Sheet 3 of 7
Key
Vehicular
circulation
Managed
slopes
Emergency
Access
Easement
Right-of-way
dedication
Existing
Channel
TMP 32-A-02-2
Submitted 17 June 2019
Revised 11 March 2020
Revised 12 May 2020
Revised 23 July 2020
Revised 10 August 2020
REVISED 08 SEPTEMBER 2020
project: 19.029
SHIMP ENGINEERING, P.C.
y
I I I I I
I
,
CYM FAbRR16 lIN PMMd9xp. ``'/
IIH,I I /
ill
l ;� tl 1 1
/ I
Disturbance of i t
Retaining wall design
managed slopes to
to follow the design
follow the design
standard in Zoning
standards in
ordinance Section 18-
Zoning ordinance `, i
I • \\
30.7.5 for any portion
Section 18-30.7.5
of the retaining wall that
Ir
Tw mz
i r
Natural
is proposed within the
aW 5a5
` ' '10
•\ recreation area 2
�
managed steep slope area
OW.500 '(approximately to,000 SF)
strian trail connects
m ramed and natural
recreation areas
SWMEPN 6T61D. Oi.MMB
D.B. 1961-20, 250 PLAT
/
ROW extends to property line. / / --
Roadway will be extended I / ---------
in accordance with Sec.14-,' _
409 of the Albemarle County,,; I ,�
Subdivision Ordinance as / •q _
amended 12-4-13, effective
I I I
I �
Programmed �
t�
recrea lon area
(approximatel, --,,Ono SF) .',
TW514 =
.
�..
TW 50 -`
_ .�.
�..'.'.
ew say
be
proffered
80 0 80 160 240
Graphic Scale: 1"=80'
rX6]011ReIjAG\7\Jd:1ZlUj&lQl l
CYM PRCPpII eM11MITET PARTRDR P
CONCEPT PLAN
D.& M11] PLAT
DB..`°`T "AT Z MA201900010
ROW extends to property line.
Roadway will be extended
in accordance with Sec.14- 3223 P RO F F I T ROAD
409 of the Albemarle County
/ Subdivision ordinance as CONCEPTUAL SITE LAYO U T
amended 12-4-13, effective
1-1-14. Sheet 4 of 7
- _
_
�`.
Ww .1xD 9lYH HET fNlRr 1MST
D.Bs Wo
"i,J•„�
6.
- 0 D.B. Po-675 PLAT
------------
rossw sown on
,
—
isconceptualsite
�n
ayout to be
"- -_
provided
DA„¢„1,. �, A,,,,r
permitted by VDOT
78
D.6.D68 s°x690 Poo
�Ia
; -
K�NWIS'
TM. J3-.MI
% raC
PlLL PAA¢ As4L¢r a aMtlAT1E .
¢d 1991 5. PUT
/
— Da 11.-n,
D69]9-wT PLAT
access;
ted for
Notes:
1. "Block A Area 1" may permit double frontage lots without
screening or with a modification to screening of double frontage
lots required by 32.7.9.7, as permitted by the agent. Waivers
and/or exceptions from the prohibition of double frontage and
screening of double frontage lots may be pursued during site plan
or subdivision plat.
2. Natural recreational area encompasses area designated as
minimally disturbed buffer and extends beyond area designated as
minimally disturbed buffer.
Key
Managed
slopes
Emergency
Access
Right-of-way
dedication
Sidewalk
Planting strip
Open space
Ll
Existing
Channel
Block A
Area 1
Crosswalk LU
TMP 32-A-02-2
Submitted 17 June 2019
Revised 11 March 2020
Revised 12 May 2020
Revised 23 July 2020
Revised 10 August 2020
REVISED 08 SEPTEMBER 2020
project: 19.029
SHIMP ENGINEERING, P.C.
ZONING MAP AMENDMENT
CONCEPT PLAN
Z MA201900010
11 aE 11 �L10 JL-6
TURN LANE TRAVEL LANE LANDSCAPE SIDEWALK
BUFFER
39.5'
PROPOSED RIGHT-OF-WAY
DEDICATION ALONG
PROFFIT ROAD
Turn lane to be provided if warranted by final use
5 0 5 10 15
Graphic Scale: 1"=5'
3ED
3223 P RO F F I T ROAD
TYPICAL STREET SECTION
Sheet 5 of 7
TMP 32-A-02-2
Submitted 17 June 2019
Revised 11 March 2020
Revised 12 May 2020
Revised 23 July 2020
Revised 10 August 2020
REVISED 08 SEPTEMBER 2020
project: 19.029
SHIMP ENGINEERING, P.C.
ZONING MAP AMENDMENT
CONCEPT PLAN
Z MA201900010
3223 P RO F F I T ROAD
TYPICAL STREET SECTION
Sheet 6 of 7
L 8' 1 10 1 10' � 2.5' 6 31F 5
PARKING TRAVEL LANE TRAVEL LANE PLANTING SIDEWALK
STRIP
57'
INTERNAL ROAD "A" & "C"
5 0 5 10 15
Graphic Scale: 1"=5'
TMP 32-A-02-2
Submitted 17 June 2019
Revised 11 March 2020
Revised 12 May 2020
Revised 23 July 2020
Revised 10 August 2020
REVISED 08 SEPTEMBER 2020
project: 19.029
SHIMP ENGINEERING, P.C.
ZONING MAP AMENDMENT
CONCEPT PLAN
Z MA201900010
10' 2.5' �- 6' �� 5' -�
TRAVEL LANE PLANTING SIDEWALK
STRIP
50'
INTERNAL ROAD "B", "D"
5 0 5 10 15
Graphic Scale: 1"=5'
3223 P RO F F I T ROAD
TYPICAL STREET SECTION
Sheet 7 of 7
TMP 32-A-02-2
Submitted 17 June 2019
Revised 11 March 2020
Revised 12 May 2020
Revised 23 July 2020
Revised 10 August 2020
REVISED 08 SEPTEMBER 2020
project: 19.029
SHIMP ENGINEERING, P.C.
ZONING MAP AMENDMENT®
3223 PROFFIT ROAD 9i'I
� i f
0
-
- ww... A __ •�I - --- 0
ZONING MAP AMENDMENT
ZMA201800006 APPROVED CONCEPT EXHIBIT
Z MA201900010
r
�
rr
�.�
r
BLOCK
---- - -
j
m
%!%!.iii
a
n
-
r
-
�
I
r
,
/
/
/f r
1
I
NW
L
/
-
3223 P IW F F 1 T ROAD
Z MA201800006
Sheet 1 of 1
project: 19.029
SHIMP ENGINEERING, P.C.