RE: Senior Center Pepsi Place — Minor Site Plan Amendment Review — SDP202000047 -
Comment Response Letter — Rev. 1
Dear Ms. Gleason:
We have reviewed your comments from October 15, 2020 Rev. 1; and made the necessary
revisions. Please find our responses to the comments below in bold lettering.
1. [32.7.9, 32.5.2(b)] Landscaping.
a. The landscape features shown on the minor site plan amendment do not appear
to match the landscape plan that was approved with the previous 1990 site plan.
The minor site plan will need to align with the previously approved landscaping
plan OR provide a landscaping plan that meets the requirements of the zoning
ordinance (Sec. 32.7.9). Review and revise accordingly.
A landscape plan has been provided to meet current zoning requirements. See Sheets
1-1.0 — L2.0.
Rev. 1: Comment acknowledged in the applicant's comment response letter. The site
plan was revised to meet current zoning requirements. See additional comments below.
b. On the Existing Conditions sheet, identify each existing tree species. A common
species name is sufficient.
Existing tree species have been noted on Sheet C2.0.
Rev. 1: Comment not fully addressed. Please identify the trees shown below.
Trees have been identified and labeled on sheet C2.0 and C2.1.
c. If a revised landscaping plan will be submitted, provide the maximum square
footage of paved parking and other vehicular circulation areas. This will be used
in the evaluation of the proposed landscaping. *Note: A copy of the 1990 site
plan can be found using the link.
Maximum square footage of paved parking/vehicular circulation areas has been
provided on Sheet 1-3.0.
Rev. 1: Additional revisions are needed. Demonstrate that the landscape plan meets the
requirements of:
ENGINEERING I DESIGN I TECHNOLOGY
d. 32.7.9.6 Landscaping within a parking area.
A requirement chart has been added to sheet 1-2.0.
e. 32.7.9.8 Tree Canopy.
A requirement chart has been added to sheet L2.0.
2. [32.5.2(n), 4.12.191 Dumpster pad. The dumpster pad does not appear to be in the
location that was approved by the 1990 site plan. Submit details and information to
show that the zoning ordinance requirements of Sec. 4.12.19 are being met by the
location shown on the current plan.
Additional dimensions have been added to Sheet C3.0 showing that the existing dumpster
enclosure meets Zoning Ordinance requirements.
Rev. 1: Comment addressed.
3. [Advisory Comment] Easement holders. Based on the proposed fence location, staff
recommends reaching out to relevant easement holders, such as Century Link,
Dominion Power, VEPCO, to make them aware of improvements that are proposed
within the respective easement areas.
Acknowledged.
Rev. 1: Comment acknowledged by applicant with the comment response letter.
4. [32.5.2(a)] Application ID. Include the application ID on the Cover Sheet
(S D P202000047).
The application ID has been added to Sheet C0.0.
Rev. 1: Comment addressed.
5. [32.5.2(a)] Zoning. Include in the Zoning Notes that this property is subject to the
Airport Impact Area and Steep Slopes (Managed and Preserved) overlay districts.
Applicable overlay districts have been added to Sheet C0.0.
Rev. 1: Comment addressed.
6. [32.5.1(c), 4.20] Setbacks. Rev. 1: Comment addressed.
a. Revise the Setback Notes to provide greater alignment with the setback
requirements provided in Sec. 4.20, whereas:
i. 20ft minimum for off-street parking or loading spaces, 50ft minimum for
structures (if abutting residential lots).
ii. In accordance with the current edition of the Building Code (if abutting
commercial lots).
b. Revise the "proposed" setback information accordingly.
All setback information has been revised as requested on Sheet C0.0.
7. [32.5.2(a), 32.5.2(n)] Building information. Provide the height and square footage of the
existing building.
Height and square footage of existing building has been provided on Sheet C0.0.
Rev. 1: Comment addressed.
8. [32.5.2(n)] Walkways. Provide width dimensions for walkways surrounding the building.
Width dimensions for walkways surrounding the building have been provided on Sheet C3.0.
Rev. 1: Comment addressed.
9. [32.5.2(a)] Steep slope areas. Locate on the plan map areas of managed and preserved
steep slopes on the subject property.
Steep slopes have been located and shown on all applicable sheets.
Rev. 1: Comment not fully addressed. Label the managed slope area shown below.
A label has been added to all sheets as well as a legend label on sheet C2.0.
10. [32.5.2(f), WRPA Ordinance] Stream and stream buffer. Rev. 1: Comment addressed.
a. Show and label the stream adjacent to the site.
The stream adjacent to the site has been shown on all applicable sheets.
b. Show and label the stream buffer area on site.
The stream buffer adjacent to the site has been shown on all applicable sheets.
11. [32.5.2(r)] Labels. Ensure all linework paralleling Greenbrier Dr on the site is labeled. It
looks like one of the lines may be an unlabeled site distance line.
All linework has been labeled for clarification. See Sheet C2.0.
Rev. 1: Comment addressed.
12. [32.5.2(i)] Easement area. Add an additional arrow(s) to help identify the bounding area
of the "R/W Easement DB 4743 PG 300" in the southwest corner of the property.
An extra arrow has been added as requested. See Sheet C2.0.
Rev. 1: Comment addressed.
13. [32.5.1(c), 32.5.2(a)] Boundary dimensions. Provide the bearings and dimensions for the
parcel boundary.
Bearings and distances have been provided for the parcel boundary. See Sheet C2.0.
Rev. 1: Comment addressed.
14. [Albemarle County Engineering Policy] Benchmarks. Reference the benchmarks used for
the survey.
Benchmarks have been shown on all applicable sheets.
Rev. 1: Comment addressed.
15. [32.5.2(a)] Departing lot lines. Show the departing lines of abutting properties.
Departing lot lines have been shown on all applicable sheets.
Rev. 1: Comment addressed.
16. [32.5.2(a)] Abutting parcel information. In addition to the TMP and ownership
information, also provide the zoning district and present uses of each abutting parcel.
Abutting parcel information, including zoning districts and present uses, have been added for
all adjacent parcels. See Sheet C2.0.
Rev. 1: Comment addressed.
17. [Advisory Comment] Linework. On Sheets C3.0 and C4.0, remove the shadow curb line
between the parcel line and the existing road curb.
The shadow curb line has been removed as requested.
Rev. 1: Comment addressed.
18. [Advisory Comment] Heading. Revise the "Zoning Site Requirements" heading on the
cover sheet to more clearly identify the proceeding information as "Site Requirements"
or "Zoning Ordinance Requirements".
The heading has been modified as requested on Sheet C0.0.
Rev. 1: Comment addressed.
Additional comments based on revised plan provided via email on 10/08/2020:
19. [Comment] On Sheet C2.1 Demolition Plan, similar to the symbolization for trees and
shrubs to be removed from the parking area ("X"), please use the same symbolization to
indicate if/when existing trees or shrubs between the building and Greenbrier Dr will be
removed.
Comment Acknowledged. The demolition plan shows all trees to be removed during the
project.
20. [Comment] Please provide a revision date for any new submittal so staff can easily track
between versions..
A revision date has been added to the title blocks.
Albemarle County Engineering Services (Engineer) — Matthew Wentland:
1. No objection.
Albemarle County Building Inspections — Michael Dellinger:
1. Sheet C1 item 29. ICC ANSI standard should be A117.1-09 instead of 03 for future
refence. Other than this, no objection.
The note has been revised on Sheet C1.0.
2. No objection.
Albemarle County Department of Fire Rescue — Shawn Maddox:
1. No Objection.
Albemarle County Service Authority— Richard Nelson:
1. Continue to work directly with ACSA.
Acknowledged.
2. Rev. 1: No Objection to the revised plan provided via email on 10/08/2020.
Acknowledged.
Virginia Department of Transportation —Adam Moore:
1. No Objection; see comment letter attached.
We have included PDF copies of the plans and calculations for your review. If you have any
questions or comments, please feel free to give me a call at 434.295.5624.
Sincerely,
Jonathan Showalter, PE
Project Manager