Loading...
HomeMy WebLinkAboutSDP202000056 Review Comments Minor Amendment 2020-10-29oe +t&, �2�y ��i u �'� in County of Albemarle Department of Community Development Memorandum To: Andrew Allison From: Megan Nedostup- Principal Planner Division: Planning Services Date: September 28, 2020 Revl: October 29, 2020 Subject: SDP-2020-056 Keswick Hall Additions- Minor Amendment The Planner for the Planning Services Division of the Albemarle County Department Community Development will recommend approve the plan referred to above when the following items have been satisfactorily addressed. (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.) [Each comment is preceded by the applicable reference to the Albemarle County Code.] Requirements: 1. Please clarify the provided parking. I counted 135 total spaces, and the plan states 246 are provided. Does that include Spa spaces? if so, those should be removed from this site plan. Revl: Comment not addressed. Per the plan there are the following: Proposed spaces: 134 Proposed handicap spaces: 7 Existing parking to remain: 107 Existing Handicap spaces to remain: 2 Total: 250 However, there is not 250 spaces. The total needs to be the total provided, not the proposed plus existing. It doesn't appear that you are adding 134 new spaces but adding 27 new spaces (134-107). Please clarify and revise accordingly. 2. Provide more information regarding the tent. There is a note on the plans that says "see landscape and structural details", however I don't see that information provided in the plans. More information is needed regarding this tent. Is this a permanent installation since anchors are being installed? What will this be used for? Covid seating for the restaurant (ie temporary)? Events? Permanent outdoor space for the restaurant? This might have parking implications. Notes should be added to the plan on the intent for the tent use. Revl: Comment addressed. 3. An email indicated that there would be lighting changes. No lighting plans were submitted. Please include all information in the letter for changes and on the plans for all changes that are being requested. Revl: Newly submitted lighting plan does not meet the requirements of section 4.17 of the zoning ordinance. Revise to include the following for all light fixtures over 3000 lumens: a. Cut sheets of the fixtures that include the height of the fixture and information that they will be full cutoff as required. b. Information on the LLF, which must be 1.0. 4. Bubbled areas are identified in the area where the spa is to be located. The information shown does not match the most recent approved spa minor amendment (SDP2020-002). If there are changes to the spa parcel and site plan, a letter of revision needs to be submitted for that site plan, and not contained on this site plan. Remove any changes to the spa site plan from this request, and this plan should indicate the limits of the spa site plan with the site plan number that it was approved under. Please contact Megan Nedostup at the Department of Community Development 296-5832 ext. 3004 for further information.