Loading...
HomeMy WebLinkAboutSDP202000010 Plan - Revision 2020-11-10PRELIMINARY CENTRAL SEWAGE SYSTEM PLAN FOR: REGENTS SCHOOL OF CHARLOTTESVILLE S D P2020-010 LEGEND TAX MAP 75, PARCEL 66 EXISTING NEW DESCRIPTION TAX MAP 76, PARCEL 17 BOUNDARIES 0!1111r BENCHMARK ALBEMARLE COUNTY, VIRGINIA SITE PROPERTY LINE ADJACENT PROPERTY LINE VICINITY MAPscALE:1 =1000' BUILDING SETBACK PARKING SETBACK OWN ER/DEVELOPER SITE TEXT Regents School of Charlottesville Inc. 10 10 PARKING COUNT 3045 Ivy Road TOPOGRAPHY Charlottesville, Virginia 22903 B U C K I N G H A M INDEX CONTOUR PLAN PREPARATION BALM 0 R A L INTERVAL CONTOUR Shimp Engineering, P.C. East High Street HEIGHTS RESERVOIR ROAD Umversdy 311.5 x n SPOT ELEVATION Charlottesville, 22902 Q Morttes5on School 311.5 TC x TOP OF CURB ELEVATION (434) 227-5140VA SITE Fontaine Research Park Q 311.5 TW x >� TOP OF WALL ELEVATION ZONING m� Rugged Mountain Q my PreSUytenan 311.5 B W x �— BOTTOM OF WALL ELEVATION EC -Entrance Corridor Hnmr+tl IC. �urch R1 - Residential — STREAM SP201800011 approved on September 18, 2019 STREAM BUFFER permitting a private school use on the site y+ and r ere•b,a 100 YEAR FLOODPLAI N MAGISTERIAL DISTRICT n BUILDING Samuel Miller BUILDING SOURCE OF TITLE RETAINING WALL DB 5237 P 251 STAIRS DB 660 P 780 (plat) EDGE OF PAVEMENT EXISTING USE IMAGE PROVIDED BY GOOGLE MAPS ROAD CENTERLINE Vacant Land FRONT OF CURB PROPOSED USE BACK OF CURB Private School (Grades K-12) I CG-12 TRUNCATED DOME 468 Students SIDEWALK NOTES BIKE PARKING Regents School site plan improvements shown for reference only. HANDICAP ACCESSIBLE AISLE This plan only proposes the new sanitary sewer system to serve .L HANDICAP PARKING Regents School and Trinity Church. (�• MATERIAL RELIABILITY CLASSIFICATION SHIMP CONCRETE Class 1 RIPRAP ENGINEERING2. ASPHALT LAND PLANNING -PROJECT MANAGEMENT EC-2 MATTING EC-3 MATTING SHEET INDEX 912E HIGH ST 434.227.5140 �� • WETLAND CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM TREELINE C1 COVER X X FENCE C2 SITE OVERVIEW UTILITY C3 SANITARY SEWER GRAVITY FLOW PLAN UTILITY POLE m m GUY WIRE C4 SANITARY SEWER FORCE MAIN PLAN �� TH q� OHU OHU OVERHEAD UTILITY CS SANITARY SEWER PROFILE & PUMP STATION DETAILS �c UGU UGU UNDERGROUND UTILITY C6 SANITARY SEWER PUMP STATION CALCULATIONS STORM U M. 9 STORM MANHOLE Lic D.1455183 itIO" " U k� q q DROP INLET STORM SEWER �rs�ONALG EEEE—RID--- a--K=R]D— ROOF DRAIN SANITARY 0 SANITARY MANHOLE SANITARY SEWER MAIN PRELIMINARY CENTRAL S S SANITARY SEWER LATERAL SEWAGE SYSTEM PLAN FOR: WATER W VV WATERLINE REGENTS ® 0 WATER METER SCHOOL 0 o WATER METER VAULT FIRE HYDRANT ALBEMARLE COUNTY, VIRGINIA A A FIRE DEPARTMENT CONNECTION SUBMISSION: GAS 2020.10.19 GAS GAS LINE EASEMENTS REVISION: CONSTRUCTION 1.2020.11.10 GRADING ACCESS SIGHT DISTANCE UTILITY STORMWATER FACILITY MAINTENANCE STORMWATER ACCESS FILE NO. DRAINAGE 18.020 SANITARY WATERLINE GASLINE COVER NOTE: 1. THE SIZE OF THE SYMBOLS MAY VARY FROM WHAT IS SHOWN. C1 / / O / NH / DAVID HA" , / D.B. 2690, PG. 54 / TM 75-61 \ / ZONE: R1 NTIA/ / USE: SINGLE FAMILYMILY R51 NTIAL I N /F / \ / RICHARD S / / D.B. TM 7 6G. 0 194 / \\ / USE: SINGLEENTIAL 7NERFAMILRESYDRESIDENTIAL N/F / / TON D B 4415, 5, PG. 7 / TM 75-61A ZONE R1 RESIDENTIAL USE: SINGLE FAMILY RESIDENTIAL > 71 7 / Cy N 4709,� 11 s � �\s9i REGENTS SCHOOL OF CHARLOTTESVILLE INC I m� D.B. 5237, PG. 251 i? TM 75-66 I 1 1 I 1 I 1 N/F 1 CECIL JOHNSON I D.B. 936, PG. 722 TM 76-14 ZONE: R1 RESIDENTIAL 1 USE: SINGLE FAMILY RESIDENTIAL 1 \ \ W'm REGENTS SCHOOL OF CHARLOTTESVILLE INC' D.B. 5237, PG. 251 TM 76-17 O I 1 1 I 1 I N/F 1 UNIVERSITY OF VIRGINIA FOUNDATION 1 D.B. 4170, PG. 689 I TM 76-13B ZONE: R1 RESIDENTIAL 1 USE: SINGLE FAMILY RESIDENTIAL 1 N 45'02'44" E 264.31' 03 A, _ REGENTS SCHOOL SITE LIMITS OF DISTURBANCE= 0.97 AC 12-1 =W W=W \ Aim n I .w.0 rri'§1Ws 4 O GAF 0 P AFT m - Wxws �U'L �s I / I � I � . / I 1 ewrwr awv ia.N. / I ' I � 1 I I � NEW GRAVITY SEWER 'I FROM REGENTS SCHOOL \ O \ 0 \ \ TRINITY PRESBYTERIAN CHURCH \\\ \\ "\ \ D.B. 730, PG. 459 \ TM 76-17C \ \ 1! f 1 1 1 \ \ \ 0 i• � i• Graphic• i• TRINITY PRESBYTERIAN CHURCH EXISTING 3" FORCE MAIN TO ACSA SANITARY SEWER SYSTEM EXISTING ACSA SANITARY SEWER SYSTEM TO REPLACE EXISTING PUMP STATION EXISTING PUMP STATION SERVES TRINITY PR .CHURCH NEW PUMP STATION TO SERVE REGENTS SCHOOL AND TRINITY PRIES. CHURCH 240 SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM U M. sfmAP a o. 45183 10[40 J�J \1AT PRELIMINARY CENTRAL SEWAGE SYSTEM PLAN FOR: REGENTS SCHOOL ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.10.19 REVISION: 1.2020.11.10 FILE NO. SITE OVERVIEW V 600 F ' 'I r CLAS ROOM C 'r\1 `J/^\TS — — — — /FE51 LLqqS 50 _ z ' F.F'E SR(yOM —\ \ \ \ i ` — — — — — — — — FL-ASSR90M IFE 514Yg0rolCo _ — — \ NEW / // \ \� —35 W NE FFE514.5 7 E Al \ —_ / BUILDING ELEVATED ON PIER N W241 LF- 8" \_ / / / / / AO �7 N \1> -�60;—_II Z \ \\ \ 1 o / I \ 1 \ \ \\ \ — I I I I I / \ \ 1 \ �� / I. � SHIMP I�� I \ \ \\ \\\�-. \\ \ \�-------- //_ l \ / I I\ �\ \\✓� / / 1 I I I I I I I A I / I 1 / / I. ENGINEERING LANDPLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 EW 20 FT PRIVATE — SANITARY SEWER EASEMENT _ � � CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM ----------- �0-)/ 00/ ( I I Y DER PA / / TH ----- / j/' / l l l l l l I I G� I I I / ZFoo / I o� �•p v ' \ Lic o.,45183 � / / / / / � / � , — — — — — — — A \ / PRELIMINARY CENTRAL SEWAGE SYSTEM PLAN FOR: / / / /' i / — — — - 3-S2 T BE BORED REGENTS \ 1 \ 1 \ \ \ SCHOOL o\ / ALBEMARLE COUNTY, VIRGINIA b / _ / SUBMISSION: \ OP \ \2020.10.19 '�� REVISION: 1.2020.11.10 FILE NO. \\�\ 18.020 - -\ \ \ \\ \ - - / / / '® _ _ - - - SANITARY SEWER \ I \ \ \ \ / \ \ \ ` \ \ \ ' SEW PUM STATION TO GRAVITY FLOW PLAN — —New 8" S \ \ RERVI" ISTING SUMP PUMP �� / �s SERVING TR ITY CHURCH \ \ \ \ \ \ \ \ 30 �0 3� 6 y0 / / / / / / — \ \pl'0 (APPROX41vv1A LOCATION) \ \ " Graphic Scale: 1 =30 a - / \ S, C 3 I � � 1, 1 1 t ddr I n f'tf)f% 11 11 S, 50 50 49 49 48 48 47 471 00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 SANITARY SEWER PROFILE GRAVITY ELOW C5 Scale: Harz: 1 "=30', Vert: 1 "=10' SS S6 n n S2 S3 n S5 S6 I 0 5 0 5 et m 5 Z � O M5 MT w CD —� wp 4. — — — oi / — r4. wow w o - rl IDJ J W O H a+ a y n �N roo _ N OJ W N a 4 H Z 0.60LF - 8" DUCTILE _ z > _ _ z O N O C5D O GO � >� z p z - D 15+50 16+00 16+50 17+00 17+50 1 M O O]M ro� O � a W O H W H - 8" S R-30:78 _ a a 95.00LF — P�SDR-35 ®0.697 n a .45L - -35 ® 0.70% z a SDR- Go _ GO GO o - - Fz z z z- z - z > z 17 00 7 + , +50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 I SANITARY SEWER PROFILE (GRAVITY FLOW) �,135 Scale: Harz: 1"=30', Vert: 1"=10' rr�an TOP VIEW CONCRETE PAD BACKUP GENERATOR CONTROL PANEL 0 23+00 23+50 24+00 510 505 500 495 490 485 480 475 0 24+50 L� N C) J- SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM v qM. 3�fIIvIP ? Lic '. 45183 14 1040 w� CONTROL PANEL BOX SHP11 CONTAIN A REMOTE MGNITGPING SYSTEM TO BE MANAGED BY A CONTRACTED a GRANTY INFLOW PROFESSIONAL THIRD PARTY. 0 0 CONTROL PANEL SUPPORT PORE & CONDUIT HIGH WATER ALARM LICNT 4•x3' REDUCER BACKUP GENERATOR CONTROL PANEL 3. 90' ELBOW � }• DISCHARGE LINE 3' DISCHARGE PLUG VALVE (3-WAY) 2' VENT PIPE PRELIMINARY CENTRAL TO 45' ELBOW CUT OF MET WELL TWO (2) W BENDS POINTED TOWARDS GROUND 3' DISCHARGE PLUG VALVE (3-WAY) SEWAGE SYSTEM PLAN FOR: 2T X 36" ALUMINUM 60. OIA. PRECABT WATERTGIIT ACCESS HATCH CWCREIE Y£T NELL T DISCHARGE FtUG(-WAY) TO 45' EB3W CUT OF WET N£LL EOVREGENTS TOP OF WET WELL ELEV. - 484.86' - 3" ELBOW - CCS TRACER WIRE INSTALLED ALONC DISCHARGE LINE 3' DISCHARGE LINE 8' D & TEE ROPL __ SCHOOL CONCRETE GENERATOR PAD FROM & DR ROWW HIGH WATER ALARM ELEV. - 181.59' — — — — — -- — — ALBEMARLE COUNTY, VIRGINIA LAG PUMP •GN•EREV._480.59' ----- ° --- SUBMISSION. — — — — — LEAD PUMP "ON" E V. _ 479.59' — — — — — 9.5 2020. 1 0. 1 9 POWER SUPPLY 1-PHASE 23OV SUBMERSIBLE PUMPS (2) MAX' 21.5A li REVISION: GOULDS W5_04 SERIES MODEL 3888D4-W530D4 ORDER N' 1.2020.11.10 ISCHARGE I 3' 90' ELBOW W/ 4"X3• REDUCER ALL PUMPS 'OFF' ELEV. = 475.32' — — PUMP INLET ELEV. = Q5.15' BOTTOM OF MET WELL ELEV. = 474.86' 5 0 " 4'X3' REDUCER FRONT VIEW SIDE VIEW s SANITARY SEWER PUMP STATION DETAILS C5 Scale: 1"=5' FILE N0. 18.020 SANITARY SEWER 30 0 30 60 90 PROFILE & PUMP STATION DETAILS Graphic Scale: Horx: 1 "=30' Vert: 1 "=10 C5 15+50 16+00 16+50 17+00 17+50 1 M O O]M ro� O � a W O H W H - 8" S R-30:78 _ a a 95.00LF — P�SDR-35 ®0.697 n a .45L - -35 ® 0.70% z a SDR- Go _ GO GO o - - Fz z z z- z - z > z 17 00 7 + , +50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 I SANITARY SEWER PROFILE (GRAVITY FLOW) �,135 Scale: Harz: 1"=30', Vert: 1"=10' rr�an TOP VIEW CONCRETE PAD BACKUP GENERATOR CONTROL PANEL 0 23+00 23+50 24+00 510 505 500 495 490 485 480 475 0 24+50 L� N C) J- SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM v qM. 3�fIIvIP ? Lic '. 45183 14 1040 w� CONTROL PANEL BOX SHP11 CONTAIN A REMOTE MGNITGPING SYSTEM TO BE MANAGED BY A CONTRACTED a GRANTY INFLOW PROFESSIONAL THIRD PARTY. 0 0 CONTROL PANEL SUPPORT PORE & CONDUIT HIGH WATER ALARM LICNT 4•x3' REDUCER BACKUP GENERATOR CONTROL PANEL 3. 90' ELBOW � }• DISCHARGE LINE 3' DISCHARGE PLUG VALVE (3-WAY) 2' VENT PIPE PRELIMINARY CENTRAL TO 45' ELBOW CUT OF MET WELL TWO (2) W BENDS POINTED TOWARDS GROUND 3' DISCHARGE PLUG VALVE (3-WAY) SEWAGE SYSTEM PLAN FOR: 2T X 36" ALUMINUM 60. OIA. PRECABT WATERTGIIT ACCESS HATCH CWCREIE Y£T NELL T DISCHARGE FtUG(-WAY) TO 45' EB3W CUT OF WET N£LL EOVREGENTS TOP OF WET WELL ELEV. - 484.86' - 3" ELBOW - CCS TRACER WIRE INSTALLED ALONC DISCHARGE LINE 3' DISCHARGE LINE 8' D & TEE ROPL __ SCHOOL CONCRETE GENERATOR PAD FROM & DR ROWW HIGH WATER ALARM ELEV. - 181.59' — — — — — -- — — ALBEMARLE COUNTY, VIRGINIA LAG PUMP •GN•EREV._480.59' ----- ° --- SUBMISSION. — — — — — LEAD PUMP "ON" E V. _ 479.59' — — — — — 9.5 2020. 1 0. 1 9 POWER SUPPLY 1-PHASE 23OV SUBMERSIBLE PUMPS (2) MAX' 21.5A li REVISION: GOULDS W5_04 SERIES MODEL 3888D4-W530D4 ORDER N' 1.2020.11.10 ISCHARGE I 3' 90' ELBOW W/ 4"X3• REDUCER ALL PUMPS 'OFF' ELEV. = 475.32' — — PUMP INLET ELEV. = Q5.15' BOTTOM OF MET WELL ELEV. = 474.86' 5 0 " 4'X3' REDUCER FRONT VIEW SIDE VIEW s SANITARY SEWER PUMP STATION DETAILS C5 Scale: 1"=5' FILE N0. 18.020 SANITARY SEWER 30 0 30 60 90 PROFILE & PUMP STATION DETAILS Graphic Scale: Horx: 1 "=30' Vert: 1 "=10 C5 + , +50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 I SANITARY SEWER PROFILE (GRAVITY FLOW) �,135 Scale: Harz: 1"=30', Vert: 1"=10' rr�an TOP VIEW CONCRETE PAD BACKUP GENERATOR CONTROL PANEL 0 23+00 23+50 24+00 510 505 500 495 490 485 480 475 0 24+50 L� N C) J- SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM v qM. 3�fIIvIP ? Lic '. 45183 14 1040 w� CONTROL PANEL BOX SHP11 CONTAIN A REMOTE MGNITGPING SYSTEM TO BE MANAGED BY A CONTRACTED a GRANTY INFLOW PROFESSIONAL THIRD PARTY. 0 0 CONTROL PANEL SUPPORT PORE & CONDUIT HIGH WATER ALARM LICNT 4•x3' REDUCER BACKUP GENERATOR CONTROL PANEL 3. 90' ELBOW � }• DISCHARGE LINE 3' DISCHARGE PLUG VALVE (3-WAY) 2' VENT PIPE PRELIMINARY CENTRAL TO 45' ELBOW CUT OF MET WELL TWO (2) W BENDS POINTED TOWARDS GROUND 3' DISCHARGE PLUG VALVE (3-WAY) SEWAGE SYSTEM PLAN FOR: 2T X 36" ALUMINUM 60. OIA. PRECABT WATERTGIIT ACCESS HATCH CWCREIE Y£T NELL T DISCHARGE FtUG(-WAY) TO 45' EB3W CUT OF WET N£LL EOVREGENTS TOP OF WET WELL ELEV. - 484.86' - 3" ELBOW - CCS TRACER WIRE INSTALLED ALONC DISCHARGE LINE 3' DISCHARGE LINE 8' D & TEE ROPL __ SCHOOL CONCRETE GENERATOR PAD FROM & DR ROWW HIGH WATER ALARM ELEV. - 181.59' — — — — — -- — — ALBEMARLE COUNTY, VIRGINIA LAG PUMP •GN•EREV._480.59' ----- ° --- SUBMISSION. — — — — — LEAD PUMP "ON" E V. _ 479.59' — — — — — 9.5 2020. 1 0. 1 9 POWER SUPPLY 1-PHASE 23OV SUBMERSIBLE PUMPS (2) MAX' 21.5A li REVISION: GOULDS W5_04 SERIES MODEL 3888D4-W530D4 ORDER N' 1.2020.11.10 ISCHARGE I 3' 90' ELBOW W/ 4"X3• REDUCER ALL PUMPS 'OFF' ELEV. = 475.32' — — PUMP INLET ELEV. = Q5.15' BOTTOM OF MET WELL ELEV. = 474.86' 5 0 " 4'X3' REDUCER FRONT VIEW SIDE VIEW s SANITARY SEWER PUMP STATION DETAILS C5 Scale: 1"=5' FILE N0. 18.020 SANITARY SEWER 30 0 30 60 90 PROFILE & PUMP STATION DETAILS Graphic Scale: Horx: 1 "=30' Vert: 1 "=10 C5 rr�an TOP VIEW CONCRETE PAD BACKUP GENERATOR CONTROL PANEL 0 23+00 23+50 24+00 510 505 500 495 490 485 480 475 0 24+50 L� N C) J- SHIMP ENGINEERING LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM v qM. 3�fIIvIP ? Lic '. 45183 14 1040 w� CONTROL PANEL BOX SHP11 CONTAIN A REMOTE MGNITGPING SYSTEM TO BE MANAGED BY A CONTRACTED a GRANTY INFLOW PROFESSIONAL THIRD PARTY. 0 0 CONTROL PANEL SUPPORT PORE & CONDUIT HIGH WATER ALARM LICNT 4•x3' REDUCER BACKUP GENERATOR CONTROL PANEL 3. 90' ELBOW � }• DISCHARGE LINE 3' DISCHARGE PLUG VALVE (3-WAY) 2' VENT PIPE PRELIMINARY CENTRAL TO 45' ELBOW CUT OF MET WELL TWO (2) W BENDS POINTED TOWARDS GROUND 3' DISCHARGE PLUG VALVE (3-WAY) SEWAGE SYSTEM PLAN FOR: 2T X 36" ALUMINUM 60. OIA. PRECABT WATERTGIIT ACCESS HATCH CWCREIE Y£T NELL T DISCHARGE FtUG(-WAY) TO 45' EB3W CUT OF WET N£LL EOVREGENTS TOP OF WET WELL ELEV. - 484.86' - 3" ELBOW - CCS TRACER WIRE INSTALLED ALONC DISCHARGE LINE 3' DISCHARGE LINE 8' D & TEE ROPL __ SCHOOL CONCRETE GENERATOR PAD FROM & DR ROWW HIGH WATER ALARM ELEV. - 181.59' — — — — — -- — — ALBEMARLE COUNTY, VIRGINIA LAG PUMP •GN•EREV._480.59' ----- ° --- SUBMISSION. — — — — — LEAD PUMP "ON" E V. _ 479.59' — — — — — 9.5 2020. 1 0. 1 9 POWER SUPPLY 1-PHASE 23OV SUBMERSIBLE PUMPS (2) MAX' 21.5A li REVISION: GOULDS W5_04 SERIES MODEL 3888D4-W530D4 ORDER N' 1.2020.11.10 ISCHARGE I 3' 90' ELBOW W/ 4"X3• REDUCER ALL PUMPS 'OFF' ELEV. = 475.32' — — PUMP INLET ELEV. = Q5.15' BOTTOM OF MET WELL ELEV. = 474.86' 5 0 " 4'X3' REDUCER FRONT VIEW SIDE VIEW s SANITARY SEWER PUMP STATION DETAILS C5 Scale: 1"=5' FILE N0. 18.020 SANITARY SEWER 30 0 30 60 90 PROFILE & PUMP STATION DETAILS Graphic Scale: Horx: 1 "=30' Vert: 1 "=10 C5 APPLICATION DATAAND CONSTRUCTION DETAILS Maximum Solid Size 3" Minimum Casing Thickness 516" Casing Corrosion Allowance W. Maximum Workin Pressure 30 PSI Maximum Submergence 50 feet Minimum Submergence Fully submerged for continuous operation 6" below top of motor for intermittent operation Maximum Environmental Temperature 400 C(104° F) continuous operation, 60*CIt40" F) intermittent operation Power Cable -Type (See Motor Information forAWG data/size.) Type SJTOW: single phase, 1 6 and 2 HP Type STOW: single phase, 1'k - 3 HP and 5 HP, 460 V Type STOW: single phase, 3 and 5 HP, three phase 5 HP, 230 V and 7rh HP Motor Cover, Bearing Housing, Seal Housing, Casing Gray Cast Iron -ASTM A48, Class 30 Impeller - Standard, Optional Gray Cast Iron -ASTM A48 or Cast Bronze - ASTM B584 C87600 Motor Shaft AISI 300 Series Stainless Steel Motor Design NEMA 56 Frame, oil filled with Class F Insulation Motor Overload Protection Single haw: on winding thermal overload protection auto reset Threephase: requires Class 10 overloads in control panel External Hardware 300 Series Stainless Steel Im ellerT a Semi -open with pump out vanes on back shroud Oil Capacity- Seal Chamber 1.5 quarts Oil Capacity - Motor Chamber life-5 HP single and threephase: 7 quarts 7%HPthreephase: 6.5 quarts Mechanical Seals - Standard Upper rbon/Ceramic; Type 21 Lower I Silicon Carbide/Silicon Carbide; Type 31 Mechanical Seals- Optional Lower I Silicon Carbiderrungsten Carbide; Type 31 (All dimensions are in inches. Do not use for construction purposes.) 25 a it FLAN E 3.50" APPLICATIONS Used in a variety of residential, commercial and industrial applications such as: • Sewage systems, Flood and Pollution Control, Dewatering/Effluent, Farms, Hospitals, Trailer Courts, Motels SPECIFICATIONS Pump: • Maximum solid size: 3" • Discharge size: 4 , 125 # ANSI flange • Maximum capacity: 620 GPM • Maximum total head: 60 feet • 300 Series stainess steel fasteners • 20' Power cord • Standard silicon carbide/silicon carbide outer seal Motor: • Maximum ambient temperature: 1040 F (40' C) continuous duty, 140' F (60' C) intermittent duty • Rated for continuous duty when fully submerged • Insulation: Class F e 60 Hertz • Single row ball bearings • 300 Series stainless steel keyed shaft Single Phase: • 1.5 - 5 HP, 208 and 230 volts e Built-in thermal overloads with automatic reset e Built-in capacitors MODELAND MOTOR Throe Phase: • 1.5 - 7.5 HP; 200, 230,460 and 575 volts • Class 10 overload protection must be provided in control panel MOTORS • Fully submerged in oil -filled chamber: High grade turbine oil surrounds motor for more efficient heat dissipation, permanent lubrication of bearings and mechanical seal for complete protection against outside environment. • Class F insulation • Designed for Continuous Operation: Pump ratings are within the motor manufacturer's recommended working limits and can be operated continuously without damage when fully submerged. • Bearings: Upper and lower heavy duty ball bearing construction for precision positioning of parts and to carry thrust loads. • Power Cable: Severe duty rated, oil and water resistant. Epoxy seal on motor end provides secondary moisture barrier in case of outer jacket damage and to prevent oil wicking. 20 foot standard with optional lengths available. • O-ring: Assures positive sealing against contaminants and oil leakage. AGENCY LISTINGS c Tested to UL 778 and CSA 22.2 108 Standards By Canadian Standards Association File #LR38549 Order No. HIP Phase VoRs RPM Impeller Dia. in. Maximum Am Lit Am KVA Code Power Cable KL Motor Efficiency % Resistance Wt. (lbs.) Start Line -Line WS1518D4M WS1512D4M 1.5 1 208 1750 5.63 17.2 50.8 B 14/3 80 1.1 0.9 195 230 14.7 29.5 E 70 1.4 1.8 WS1538D4M WS1532D4M 3 200 11.5 40.9 H 1414 81 NA 1.7 230 10.0 40.0 F 83 P.3 W 15 4D4M WS1537D4M 46 5.0 20.0 F 9.3 575 4.0 14.4 H 74 14.8 WS1518D4 WS1512D4 WS1538D4 WSM2D4 1.5 1 208 1750 6.25 17.2 50.8 B 14/3 80 1.1 0.9 195 230 14.7 29.5 E 70 1.4 1.8 3 200 11.5 40.9 H 14/4 81 NA 1.7 230 10.0 40.0 F 83 2.3 W 15 4D4 WS1537D4 46 5.0 I 20.0 11 8 9.3 575 4.0 1 14.4 1 H 74 14.8 WS2018D4 WS2012D4 WS2038D4 WS2032D4 WS203404 2 1 208 1750 6.63 20.3 50.8 B 14/3 80 1.1 0.9 200 230 17.3 36.9 D 75 1.4 1.5 3 200 13.3 40.9 H 14/4 81 NA 1.7 230 1 40.0 F 83 2.3 460 5.8 20.0 F 83 9.3 W52037D4 575 4.6 14.4 H 74 14.8 WS3018D4 iWS3012D4i WS3038D4 WS303204 3 208 1750.': 7.00 25.5 50.8 B �C; f10%3. 80 1.1 09 ;230� ;21.5', '46.41 7T �.TO) 1..0' 3 200 16.6 53.8 G 10/4 85 NA 1.3 205 230 14.4 49.5 H 14/4 83 1.9 WS3034D4 W53037D4 460 7.2 24.8 H 83 75 575 5.8 17.3 G 78 i 11.6 WS5012D4 WS5038D4 5 1 230 1750 7.25 26.5 57.7 A 10/3 80 1.0 0.8 213 3 200 19.1 73.9 F 10/4 84 0.9 210 14/4 WS5037D4 575 6.6 22.8 E 80 7.4 WS7532D4 WS7534D4 7.5 3 230 1750 7.69 23.0 105.0 G 10/4 83 NA 0.7 225 460 11.5 52.5 G 83 2.8 WS7537D4 575 9.2 42.0 E 84 4.4 2 PUMP SPECIFICATIONS C6 Scale: N/A Discharge Pipe Information Pipe 1 3" force main Pipe 1 Pipe length (feet) 450 it Pipe diameter (inches) 3 in Pipe C-factor 120 Portion of Flow 1 Cross -sectional area (feet) 0.049 it Hydraulic radius 0.063 it Suction water surface elevation (A) 474.34 feet Suction water surface elevation (B) 475.34 feet Discharge water surface elevation 500.00 feet Static head (A) 25,7 feet Static head (B) 24.7 feet Daily Average Flowrates Type: Unit: Nu(rber of Units: qpcVunit Total Grade School w/ Showers Each 466 16 7,486 *Church w/ Daycare Each 50.68 25 1,267 ' estirrate based on water bill data Overage. Total 8,755 Daily Peak Flowrates Type: Unit: Nurrber of Units: Daily Average Flow gpd 8,755 Daily Average Flow gpm 6.08 Peaking factor n/a 2.5 Peak Daily Flow gpm 15.20 Wet Well Sizing Type: Unit: Nurrber of Units: Diameter ft 5 Volume perfoot gallons 100 Wet Working Depth ft 4.73 Total Storage gallons 1,422 Pumping Rate gpm 67 Time to Empy minutes 21 Ave-(gpm) Design Pump Row: is DuplexPLrrp (2 Rxrps) Parameter Plessure Rpe Length, (ft) Rpe Dia., (in) HazerrWilliarrs Coati C 450 3 120 *Pipirg from purrp basin to dscharge, pant Minor Losses Type K-values # Fittino Cate Valve 0.19 0 loug Valve 99% en 0.86 1 BUtedlyValve 0.4 0 Swina Check Valve 2.5 1 90* Bard 0.25 0 45* Bend 0.2 0 22.5" Bend 0.12 0 11.26* Bend 0.06 0 Tee thr h 0.6 0 Tee side oull 1.8 0 Cross throh 0.6 0 Cross side att 1.8 0 Redlcer Increaser 0.1 0 Disoharcie to air 1 1 System & Pump Curves - Regents School/Trinity Church 70.00 60.00 _- ---.. 40.00 _ TDH - Max. TDH - Min. 30.00 - - -A- Pump 20.00 -EL i7 10.00 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 Flow (gpm) . a E 0 m 3 0 N a)O � LL � 3 on � ra � o � °p v � .a a O N N o a a a System Curve - Head Loss Calculations Flowrate Water Velocity In: Dynamic Losses, ft Total Dynamic Head Total Dynamic Head (+20%) gpm cfs Velocity ft/s Minor Losses Pipe Friction Max. Lift ft Min. Lift ft Max. Lift ft Min. Lift ft 0 0 0 0 0 25.66 24.66 30.79 29.59 5 0.01 0.23 0.00 0.06 25.73 24.73 30.87 29.67 10 0.02 0.45 0.01 0.23 25.90 24.90 31.08 29.88 15 0.03 0.68 0.03 0.48 26.17 25.17 31.40 30.20 20 0.04 0.91 0.06 0.82 26.53 25.53 31.84 30.64 25 0.06 1.13 0.09 1.23 26.98 25.98 32.37 31.17 30 0.07 1.36 0.13 1.73 27.51 26.51 33.01 31.81 35 0.08 1.59 0.17 2.30 28.13 27.13 33.75 32.55 40 0.09 1.82 0.22 2.94 28.82 27.82 34.59 33.39 45 0.10 2.04 0.28 3.65 29.60 28.60 35.52 34.32 50 0.11 2.27 0.35 4.44 30.45 29.45 36.54 35.34 55 0.12 2.50 0.42 5.30 31.38 30.38 37.65 36.45 60 0.13 2.72 0.50 6.22 32.38 31.38 38.86 37.66 65 0.14 2.95 0.59 7.21 33.46 32.46 40.16 38.96 70 0.16 3.18 0.68 8.27 34.62 33.62 41.54 40.34 75 0.17 3.40 0.78 9.40 35.85 34.85 43.02 41.82 80 0.18 3.63 0.89 10.59 37.15 36.15 44.58 43.38 85 0.19 3.86 1.01 11.85 38.52 37.52 46.22 45.02 90 0.20 4.08 1.13 13.17 39.96 38.96 47.96 46.76 95 0.21 4.31 1.26 14.56 41.48 40.48 49.77 48.57 100 0.22 4.54 1.39 16.01 43.06 4206. 51.68 50.48 Wet Well Calculations Wet Well Diameter 5 ft Wet Well Height 10 ft Pump Rate 67 gpm *Pump rate is where system curve and pump curve cross Min active wetwell volume: 1) Min of 1 minute pump rate time 67 gallons 2) 10 minutes pump cycle time( 3 cycles/hr/pump) 167.5 gallons Dimensions of sloped portion around base ofwetwell (t): height= 1.00 width = 1.00 Volume per foot of depth ofwetwell : Depth (ft) Volume (gal) 0 0 1 100 2 247 3 394 4 540 5 687 6 834 7 981 8 1128 9 1275 10 1422 Inflow rate into Wet Well Qin= Discharge Flow Out of Wet Well Qout= Tmin= 15.20 gpm 67.00 gpm 0 min Minimum Submergence Hx Fd= 0.012 Hx= 0.172 ft Hmin= 4.265 ft 0.034 cfs 0.149 cfs Pump settings: 1) Bottom ofwetwell 474.86 ft 2) Pump Inlet 475.15 ft 2) At pumps off 475.32 ft 3) Lead pump on 479.59 ft (Condition A) 4) Lag pump on 480.59 ft (Condition B) 5) High Water Alarm 481.59 ft 6) Top of wet well 484.86 ft 3 PUMP STATION CALCULATIONS C6 Scale: N/A SYSTEM & PUMP CURVES C6 Scale: N/A Pump Selection Pump 5 Goulds WS_D4 Series Model: 3888D4 WS30D4 Oder No. WS3012D4 3 " (Solids) 4"Discharge Flange 1-Phase 230V 1750 RPM Max Amps: 21.5 Flow Pump 5 TDH (gpm) TDH (ft) 0 46.00 5 45.50 10 45.00 15 44.50 20 44.00 25 43.75 30 43.50 35 42.88 40 42.25 45 42.13 50 4200. 55 41.50 60 41.00 65 40.63 70 40.25 75 40.13 80 40.00 85 39.50 90 39.00 95 38.75 100 38.50 105 38.25 110 38.00 115 37.75 120 37.50 125 37.00 130 36.50 SHIMP ENGINEERIN 32 LAND PLANNING - PROJECT MANAGEMENT 912 E. HIGH ST. 434.227.5140 CHARLOTTESVILLE VA, 22902 JUSTIN@SHIMP-ENGINEERING.COM 10 l M 183 0 PRELIMINARY CENTRAL SEWAGE SYSTEM PLAN FOR: REGENTS SCHOOL ALBEMARLE COUNTY, VIRGINIA SUBMISSION: 2020.10.19 REVISION: 1.2020.11.10 FILE NO. 18.020 SANITARY SEWER PUMP STATION CALCULATIONS C6