Loading...
HomeMy WebLinkAboutWPO201500044 Review Comments WPO VSMP 2015-07-30John Anderson From: Alan Franklin <afranklin @waterstreetstudio.net> Sent: Thursday, July 30, 2015 1:44 PM To: John Anderson Cc: Johnathan Newberry Subject: RE: Bundoran Lot 81-11D I follow. Will get right on it. Thanks alot, Alan From: John Anderson [ mailto :janderson2 @albemarle.org] Sent: Wednesday, July 29, 2015 5:54 PM To: Alan Franklin Cc: Johnathan Newberry Subject: RE: Bundoran Lot 8HD Alan, Level spreader design and location must avoid stream buffer. We've pressed as much as we can. It is reasonable to propose culverts, but please focus on areas upslope /outside of 100' buffers for level spreaders. Highlight locations below that run with contours may or may not work, but my sense and recommendation are for more level spreaders (13' L or less) with ditch discontinuous downslope. With more level spreaders, there is reasonable expectation that concentrated ditch flow may in fact become sheet flow —which is what we need to comply with 9VAC25- 870 -66.D. 1) Irxreased Y41LInes Of sha6t kW F195URIFMJ ROM pervious or dbsconnecfed Impetuous areas, yr from physical spreading of concentrated Row througn level spreadairs, must be identified and evaluated for potential impacts on down - gradient prupertas or resources Increased volumes of sheet flow that YM cause or conthlbale to erosion. sedimentalon. or Ooo&ng of down gradranl pioperlies or resources shad be divarled to a stonmaler management faerhly or a stormwater canwyanca system thal conveys Ilia runoff wiuioul causing do wn gracfient erosion, sedirnentatron, or flooding. If all runoff from the svte cs sheet Row and the c or`dibans of this wbsection are mal_ no furlher water quanMy corrtrors are required Please revise. Please show ditch discontinuous 5 -10' below ea. Level spreader, then show ditch beginning again. Culverts are reasonable, but we cannot approve level spreaders in the stream buffer. Provide only ESC outlet protection (OP /stone aprons) at culvert outfalls. RAP LNNG, Typ aribwl? - 1 N + 711f1 .Sy t. \' * +'• wl NEW 34' LU7E6 k A-CC1;9SEA8ENe nR 7€ 13JnFikt x } I r ~ y rLOJ4 1 .. 'w rm 61;GTI Ns . i w '. .?ELFQF 6'CULwEIit 4•.' - INV deMT6 T t y. per~ ENOS€CTIONS . y• Ud+CUTINW.. IfN RIE9E40r' ' 11 TSUF iT7EAMCR X1101) ,6 ReANCE S'IP .-k .-- L } lye _ Thy 9Ff' T.lffrt t,W Tc 43 L13M 8, ic 193 CFl 14'-11 M404 3 7'lP G+T TYR 4t + 1 RAP IPNO4a2FLEVEL F + - — t - A4+ KWiS.F) Tyr 4 6 P6# Yi KOV VI? I xy+ = l X000 aF iao sTi0.F UPI ICE } k-7 Alan, You have the right idea —sheet 3 Level Spreader with Rigid Lip is the right detail, but please consider label /note that states that Level Spreaders shown with this design are not Water Quali BMPs, that VA DEQ Stormwater Design Specification No. 2 downslope profile may or may not be achievable. Please revise `Maintenance Easement' label to read `SWM Access Easement' This easement allows Alb. County access to inspect/maintain LS (if need be). Level spreaders are considered SWM facilities in that they are means by which concentrated flow is converted to sheet flow. They are quantijy control as opposed to quality control, but SWM facilities nonetheless. They are not ESC measures and will require SWM bond, maintenance agreement, and (SWM Access) Deed of Easement. JT is better positioned to offer guidance /advice on Access easement requirements. The proposed planting grid works but a diagonal or diamond pattern may give canopies more space. Without reference to clear guide, it's intuition; square pattern is acceptable, but diagonal may be better. Last, and more an item for Hunter or Josh, property owners of parcels proposed to receive Mitigation plantings will be party to Mitigation Plan bond. Please feel free to pass this along, and feel free to call. Thanks for pulling this together so quickly, Alan. I will respond as quickly as I can. Please continue to send .PDFs- 434.296 -5832 —x3069 4 0 k 4ADw D OR PnE !91CDJHG 551 KARDWOOD ANDPDR ME! 5EEDLHGS WN TiJM& AND MATS MITIGATION PLANTING GRID From: Alan Franklin [ma ilto: af ran klin @waterstreetstudio.net] Sent: Tuesday, July 28, 2015 10:57 AM To: John Anderson <janderson2 @albemarle.org> Subject: RE: Bundoran Lot 8HD I prepared a SWPPP report using the template as well but I must not have hit save. Back to the drawing board. From: John Anderson [ma i Ito: janderson2 @albemarle.orq] Sent: Tuesday, July 28, 2015 10:38 AM To: Alan Franklin Subject: RE: Bundoran Lot 8HD Alan, Can you send .PDFs for me to preview? - thanks From: Alan Franklin [ma ilto: af ran klin @waterstreetstudio.net] Sent: Monday, July 27, 2015 3:03 PM To: John Anderson <janderson2 @albemarle.org> Subject: Bundoran Lot 8HD John, I've completed the plans and calculations and Josh gave me a copy of a previously submitted application to submit. Is that really going to work when I go to submit? What else do we need? Alan waterstreet studio 418 East Main Street Charlottesville VA 22902 434.295.8177 www.waterstreetstudio.net I facebook I twitter