HomeMy WebLinkAboutWPO201500044 Review Comments WPO VSMP 2015-08-25 (2)John Anderson From: John Anderson Sent: Tuesday, August 18, 2015 11:21 AM To: 'Alan Franklin' Cc: Josh Woodson; Hunter McCardle; Geoff Elsie Subject: RE: Bundoran Farm Lot H81D Attachments: WPO_VSMP_Virginia_Stormwater_ Management _Program_Application.pdf; CGP Reg istration State ment2014 .pdf Alan, this is fine. Please submit VSMP Application, 2 copies (Attached) + fee ($145 —this is half total; remaining half of the Application fee is due at pre - construction meeting), Check blocks A. — H. Block A. — Owners: include owner /s of property to receive Mitigation planting (owners must sign). List all TMPs affected by site work, driveway, or Mitigation Plan. Block B. —List total Ac. proposed to be disturbed, 0.98 Ac. Please confirm this value is accurate —shown as 42,500 SF on plan. Block C. — Complete Attached General VPDES Permit Registration Statement. [Not strictly required since <1.0 Ac., so close, however, we request this form to be safe.] Submit with Application. Block F. /G. — check, but include no documents. Geoff Elsie will work with builders, will require single - family SWPPP as condition of building permit, each Lot —this addresses F. /G. requirements. May include note to this effect. resources / stream are protected with SF /riprap culvert outfall protection during driveway construction, and are protected from post - developed runoff via ELSs design. Thanks, everyone From: Alan Franklin [mailto:afranklin @waterstreetstudio.net] Sent: Monday, August 17, 2015 2:15 PM To: John Anderson <janderson2 @albemarle.org> Cc: Josh Woodson <j.woodson @naturalretreats.com >; Hunter McCardle <h.mccardle @naturalretreats.com> Subject: RE: Bundoran Farm Lot H8D John, 1. I've tweaked the Culvert 1 inverts and calculations to match. 2. Added dimensions and a detail for rip rap outlet protection for Culvert 2. 3. Added the missing information for LS 4 on the plan. What do we do next? Alan From: John Anderson [ mai Ito: janderson2Cabalbemarle.org] Sent: Tuesday, August 11, 2015 6:39 AM To: Alan Franklin Cc: Josh Woodson; Hunter McCardle Subject: RE: Bundoran Farm Lot H81D Alan, 1. Culvert 1, INV Elev. DN =951.0 (culvert l.PDF); compare with plan — please revise plan. 2. Please dimension culv. 2 riprap outfall protection: L X W x D + class stone (rich detail, may have overlooked). 3. Please provide DA for LS 4 Qio — should not prove critical (for consistency). Design L sufficient for Q2 discharge 0.93 CFS). 4. Mitigation Plan is Acceptable; comments addressed. Alan, design excels. If you'd like to resend, last preview < day /same day, then, submit. Thanks for your patience. From: Alan Franklin [ma ilto: af ran klin @waterstreetstudio.net] Sent: Tuesday, August 04, 2015 2:53 PM To: John Anderson <]anderson2 @albemarle.org >; Josh Woodson <Lwoodson @naturaI retreats. com >; h.mccardle @naturalretreats.com Subject: Bundoran Farm Lot H8D John, Revised plan in response to your comments. Thanks, Alan Franklin, PE waterstreet audio 418 East Main Street Charlottesville VA 22902 434.295.8177 www.waterstreetstudio.net I facebook I twitter