Loading...
HomeMy WebLinkAboutARB202000125 Plan - Submittal (First) Initial Site Plan 2020-11-16GENERAL NOTES APPLICANT: 05BA2-00— 00-02100 SCOTT'S IVY EXXON 4260 IVY ROAD CHARLOTTESVILLE, VA 22903 OWNER: SR&DR LLC 1031 MILTON DRIVE KESWICK, VA 22947 ENGINEER: COLLINS ENGINEERING 200 GARRETT ST. SUITE K, CHARLOTTESVILLE, VA 22902 TELEPHONE (434)293-3719 FAX (434)293-2813 CONTACT MR. SCOTT COLLINS, P.E. scot t0collins—engineering. com TAX MAP NO. 058A2-00-00-02100 (D.B. 5139/ PG. 134) AREA 1.587 AC ZONING C-1 COMMERCIAL, WITH FLOODPLAIN, CRITICAL SLOPES, & ENTRANCE CORRIDOR (EC) OVERLAY DISTRICTS NOTE: A SPECIAL USE PERMIT (SP 2020-06) WAS APPROVED BY THE BOS ON AUGUST 19, 2020 FOR THE USE OF THE PROPERTY AS AN AUTO SERVICE STATION WHEN NOT SERVED BY PUBLIC WATER OR AN APPROVED CENTRAL WATER SUPPLY. SETBACKS FRONT BUILDING SETBACK: 10' MINIMUM AND 30' MAXIMUM SETBACK FROM ROUTE 250 SIDE & REAR BUILDING SETBACK ABUTTING ZONED RESIDENTIAL USES: 50' MINIMUM & NO MAXIMUM SETBACK SIDE & REAR BUILDING SETBACK ABUTTING ZONED COMMERCIAL/INDUSTRIAL USES' SEPARA77ON IN ACCORDANCE WITH CURRENT BUILDING CODE PARKING SETBACK: 10' PARKING SETBACK FROM ROUTE 250 BUILDING HEIGHT MAXIMUM BUILDING HEIGHT: 65 FEET PROPOSED BUILDING HEIGHT24 CURRENT/PROPOSED USE: AUTO SERVICE STAT70N WITH (3) EXISTING SERVICE BAYS AND (4) PROPOSED SERVICE BAYS WITHIN THE 3,200 SF BUILDING EXPANSION CURRENT BUILDING: 1,950 SF W/ (3) SERVICE BAYS PROPOSED BUILDING EXPANSION: 3,200 SF W/ (4) SERVICE BAYS TOPO & SURVEY SURVEY AND BOUNDARY INFORMATION PROVIDED BY MERIDIAN PLANNING GROUP. AND FIELD SURVEY WAS PERFORMED IN FEBRUARY, 2020. DATUM SET BY SURVEYOR. DATUM NAD 83 DATUM ADJACENT PROPERTY OWNERS: SEE EXISTING CONDITIONS, SHEET 2. EXISTING VEGETATION THE SITE IS PARTIALLY WOODED IN THE REAR OF THE PROPERTY. CRITICAL SLOPES IN ACCORDANCE WITH THE ALBEMARLE COUNTY CRITICAL SLOPES COUNTY MAPPING, CRITICAL SLOPES EXIST ON THE PROPERTY AND ARE SHOWN ON SHEETS 2 AND 4. WATERSHED THIS DEVELOPMENT LIES WITHIN THE MOORES CREEK WATERSHED. THE SITE IS NOT LOCATED WITHIN A PUBLIC WATER SUPPLY RESERVOIR WATERSHED, IT IS LOCATED DOWNSLOPE FROM THE SOUTH FORK RIVANNA WATER SUPPLY WATERSHED. FLOODPLAIN/WPO BUFFERS THERE IS A 100—YEAR FLOODPLAIN AND WATER PROTECT70N BUFFER LOCATED ON THIS SITE PER FEMA MAP PANEL //51003CO265D DATED FEBRUARY 4, 2005 & COUNTY GIS, RESPECTFULLY. ALSO NOTE THE PARCEL IS OUTSIDE THE LIMITS OF THE FEDERAL & STATE DAM BREAK INUNDAT70N ZONES PER COUNTY GIS DATA. SITE ACCESS' THE SITE ACCESS FOR THE PARCEL IS PROVIDED VIA ROUTE 250 (IVY ROAD). THERE IS AN EXISTING ACCESS EASEMENT ACROSS A PORT70N OF THE PROPERTY TO SERVICE PARCEL TMP 58A2-24C & 58A2-24. THE ACCESS EASEMENT WILL BE EXPANDED WITH THE S17E PLAN AND PLATTED WITH AN EASEMENT PLAT RETAINING WALLS: NO RETAINING WALLS ARE PROPOSED WITH 7HE PROJECT LIGHTING: 7HE SERVICE STAT70N HAS EXIS77NG LIGHTS ON THE BUILDING AND CANOPY THAT WILL REMAIN. THE CANOPY HAS (8) EXIS77NG LED LIGHTS THERE ARE (2) EXIS77NG STREET LIGHTS ON THE PROPERTY TO REMAIN, AS SHOWN ON SHEET J. NO ADDIT70NAL LIGHTING IS PROPOSED AT THE FRONT OF THE SITE, AT THE CANOPY, OR ALONG THE FRONT OF THE EXISTING BUILDING. NEW BUILDING LIGHTS ARE PROPOSED IN THE REAR OF THE SITE AS SHOWN ON THE SITE PLAN. A FINAL LIGHTING PLAN WILL BE INCLUDED WITH THE FINAL SITE PLAN. EACH OUTDOOR LUMINAIRE EQUIPPED WITH A LAMP THAT EMITS 3,000 OR MORE INITIAL LUMENS SHALL BE A FULL CUTOFF LUMINAIRE AND SHALL BE ARRANGED OR SHIELDED TO REFLECT LIGHT AWAY FROM ADJOINING PROPERTIES AND AWAY FROM ADJACENT ROADS. THE SPILLOVER OF LIGHTING FROM LUMINAIRES ONTO PUBLIC ROADS AND ADJACENT PROPERTIES SHALL NOT EXCEED ONE—HALF FOOTCANDLE. LANDSCAPING: A LANDSCAPING PLAN HAS BEEN INCLUDED IN ACCORDANCE WITH ALBEMARLE COUNTY ORDINANCE SECTION 32.7.9, SEE SHEET 6. STREET TREES HAVE BEEN PROVIDED WITH THE LANDSCAPING DESIGN ALONG THE FRONTAGE OF THE PROPERTY EVERY 40' O.C. TRASH COLLECTION: AN ENCLOSED DUMPSTER SCREENED WITH LANDSCAPING IS PROVIDED ON THE PLANS. DUMPSTER ENCLOSURE MATERIAL SHALL BE A WOODEN TRASH ENCLOSURE LOCATED BEHIND THE BUILDING. SEE SHEET 6 FOR DETAILS. UTILITIES: AN EXISTING PRIVATE WELL AND SEPTIC SYSTEM WILL PROVIDE WATER AND SEWER SERVICE FOR THE AUTO SERVICE STAT70N EXPANSION. STORMWA TER MANAGEMENT FACILITY: STORMWATER MANAGEMENT WILL BE ACHIEVED FOR THE SITE WITH AN ONSITE SWM FACILITY AND DETENTION BASIN. THE FACILITY SHALL PROVIDE WATER QUAN77TY CONTROL FOR THE SITE WATER QUALITY SHALL BE ACHIEVED ONSITE WITH THE STORMWA TER MANAGEMENT FACILITY, FOREST AND OPEN SPACE EASEMENTS, AND/OR THE PURCHASE OF NUTRIENT CREDITS. ESTIMATED EMPLOYEES IT IS ANTICIPATED THAT APPROXIMATELY 10 EMPLOYEES WILL BE NEEDED AT THE LARGEST SHIFT. PARKING LOT/TRAVELWAYS CURB & GUTTER AGRICULTURAL/ FORESTAL DISTRICT: NONE IMPERVIOUS AREAS: BUILDING: 5,150 SF PAVEMENT/GRAVEL AREA: 28,480 SF SIDEWALK: 600 SF OPEN SPACE.' NONE PARKING REQUIRED: 1 SPACE/EMPLOYEE = MN. 10 EMPLOYEES x 1 SP/EMPLOYEE = 10 SPACES 2 SPACES / SERVICE STALL = 7 SERVICE STALLS x 2 SPACES = 14 SPACES TOTAL SPACES REQUIRED: 24 PARKING SPACES PROVIDED: 17 PARKING SPACES AVAILABLE TO THE PUBLIC (THIS INCLUDES 1 HANDICAP SPACE) 12 SERVICE SPACES IN THE GRAVEL STORAGE LOT BURIAL SITE: NO CEMETERIES WERE FOUND DURING FIELD INVESTIGATION OF THE SITE IMPERVIOUS AREAS: 34,230 SF (0.78 AC) TOTAL (507 IMPER WOUS SITE) PAVED PARKING AND CIRCULATION AREA: 28,480 SF PHASING. THIS PROJECT WILL DEVELOPMENT WITH (1) PHASE. SCOTT'S IVY EXXON INITIAL SITE PLAN SAMUEL MILLER MAGISTERIAL DISTRICT ALBEMARLE COUNTY, VIRGINIA GRAPHIC SCALE 3e ° 5 ( IN FEET ) 1 inch = 30 ft. Benchmark: F Iron Found N: 3908385.82 E. 11455502.05 Elev: 539.11 / / / / TMP 58A2-20 LENVIC, LLC DB 3801 PG 750 ZONED: C1 I I I I I I I I I — — — — — SIGN — � I I 20 120 WELL 20 D ASH CIw.,, SHED TMP 58A2-21 (PART 1) \F I I I I I I N73'50'25°W I 10.55' N22'50'28"W 16.58' TMP 58A2-20A JOSEPH W RICHMOND Jr TRUST DB 4992 PG 686 \ PLANTING ASPHALT BEDS ENTRANCE IF SHEtT LAYOUT SCALE: 1" = 30' I I / I I / w TMP 58A2-24C �p RIVANNA WATER & SEWER 2 AUTHORITY ZONED: C1 I H ILL ON \ d 7 I SR & DR, LLC - I DB 5139 PG 134 10 PARADISE ` ZONED: Cf ' 10 EDAD 1.587 AC 8 PARAUI pARADIS- I EX. RESIDENTIAL HOUSE #4272 i IF 12 TRP MAPLE, UP WOOD N0127'O6"E 20.00' NOTES: CONTRACTOR SHALL VERIFY LOCATION AND ELEVATION OF ALL UNDERGROUND UTILITIES SHOWN ON PLANS IN AREAS OF CONSTRUCTION PRIOR TO STARTING WORK. CONTACT ENGINEER IMMEDIATELY IF LOCATION OR ELEVATION IS DIFFERENT FROM THAT SHOWN ON THE PLANS, IF THERE APPEARS TO BE A CONFLICT, AND UPON DISCOVERY OF ANY UTILITY NOT SHOWN ON THE PLANS. THE CONTRACTOR MUST LOCATE ALL SURFACE AND SUB -SURFACE UTILITIES PRIOR TO ANY WORK ONSITE. ANY SIDEWALK AND/OR CURB DAMAGE IDENTIFIED IN THE SITE VICINITY DUE TO PROJECT CONSTRUCTION ACTIVITIES AS DETERMINED BY THE VDOT INSPECTOR SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. SIDEWALK WILL BE REPLACED AT THE DIRECTION OF THE VDOT INSPECTOR. ANY EXISTING SIDEWALK THAT IS CURRENTLY DAMAGED AND IN NEED OF REPAIR OR NOT IN COMPLIANCE WITH CURRENT STANDARDS SHOULD BE REPLACED AS PART OF THIS PROJECT AS WELL. IN ADDITION, ANY EXISTING CG-12S ALONG THE PERIMETER OF THE SITE SHOULD BE UPGRADED TO MEET CURRENT STANDARD IF NEEDED. ALL SIGNING AND PAVEMENT MARKINGS SHALL BE CONSISTENT WITH THE MUTCD. ALL WATER LINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. WADI 15 ` 15 '. PARADISE �f � 4RADI�(2Xl SEPTIC TANK LID - TMP 58A2-24 EATON, LOUIS S OR SUSAN E ZONED: RA ------- Benchmark `l Nail Found o U.S. ROUTE 250 EXISTING N: 13908037.54 1455637.8 �I IVY ROAD PAVEMENT E. v: 55637.87 80' R/W ROAD PAINT Elev: 517.13 DB 231 PG 585 (STRIPING) TRAFFIC GENERATION CALCULATIONS: TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL 10TH EDITION PROPOSED GASOLINE/SERVICE STATION W/ 2 EXISTING PUMPS (CODE 944) ACT: 2 EXISTING PUMPS x 172 VPD = 344 VPD AM PEAK: 10.28 TRIPS/HR x 2 PUMPS = 20 VPH (10 IN & 10 OUT) PM PEAK: 14.03 TRIPS/HR x 2 PUMPS = 28 VPH (14 IN & 14 OUT) ENTRANCE CORRIDOR NOTES AND REQUIREMENTS: 1. VISIBILITY OF ALL MECHANICAL EQUIPMENT FROM THE ENTRANCE CORRIDOR SHALL BE ELIMINATED. 2. ALL SIGNS FOR THE SITE SHALL BE REVIEWED AND APPROVED BY ARB UNDER A SEPARATE SIGN APPLICATION. NOTES: 1. THE SERVICE STATION SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 18.5.1.20 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. THIS INCLUDES THE SALE OR STORAGE OF THE PETROLEUM PRODUCTS SHALL SATISFY THE REQUIREMENTS ESTABLISHED BY THE FIRE PREVENTION CODE, AND NO NEW STORAGE TANKS OR LOADING FACILITIES SHALL BE LOCATED CLOSER THAN 100 FEET FROM ANY LOT LINE. 2. ALL PARTS, MATERIALS AND EQUIPMENT SHALL BE STORED WITHIN AN ENCLOSED BUILDING. 3. NO VEHICLE AWAITING REPAIR SHALL BE LOCATED ON ANY PORTION OF THE SITE SO AS TO BE VISIBLE FROM ANY PUBLIC STREET OR ANY RESIDENTIAL PROPERTY, AND SHALL BE LIMITED TO LOCATIONS DESIGNATED ON THE APPROVED SITE PLAN. 4. ALL SERVICES SHALL BE PERFORMED WITHIN AN ENCLOSED BUILDING. 5. NO BUILDINGS IN WHICH SERVICES ARE PERFORMED SHALL BE LOCATED CLOSER THAN 50 FEET FROM ANY RESIDENTIAL OR AGRICULTURAL DISTRICT. i � \ DB 22 PG 43 I 2°'e V. v Clover Lake � n5 Me.,.,e•„"a � � R SUBJECT PROPERTY i�yRa �ce� UPlkd SWt P. a, e " , IVY Rd Ivy Rd p VICINITY MAP SCALE: 1" = 11000, Sheet List Table - SITE PLAN � \ DB 22 PG 43 I 2°'e V. v Clover Lake � n5 Me.,.,e•„"a � � R SUBJECT PROPERTY i�yRa �ce� UPlkd SWt P. a, e " , IVY Rd Ivy Rd p VICINITY MAP SCALE: 1" = 11000, Sheet List Table - SITE PLAN Sheet Number Sheet Title 1 COVER 2 EXISTING CONDITIONS & DEMOLITION PLAN 3 SITE PLAN 4 GRADING & DRAINAGE PLAN 5 LANDSCAPING PLAN 6 NOTES & DETAILS C: TOTAL NUMBER OF SHEETS RESOLUTION TO APPROVE SP 202000006 SCOTT'S IVY EXXON BE IT RESOLVED that, upon consideration of the staff reports prepared for SP 20 000006 and all of their attachments, the info ation presented at the public hearings, any written comments eceived, and the factors relevant to special use permits in Albemarle County Code §§ 18-22.2.2(16)(a) aru 18-33.40, the Albemarle County Board of upervisors hereby approves SP 202000006, subject to the cond lions attached hereto. ass 1, Claudette K. Borgersen, do hereby certify that the foregoing writing is It true, correct copy f a Resolution duly adopted by the Board of Supervisors of Albemarle County, Virginia, by a vote of six to Eero, as recorded below, at a regular I iceting held on August 19, 2020. Cler , Board of County S is rs —Aye Nay Mr. Gallaway Y Ms. LaPisto-Kirtley Y Ms. Mallek Y -Ms. McKee] Y _ Ms. Palmer Y Ms. Price Y SP2020-06 Scott's Ivy Exxon SpecialI Use Per halt Conditions 1. Development of the use must be in general accord, as determined by the Director of Tanning and the Zoning Administrator, with the Conceptual Plan titled "Scott's Ivy Exxon — Special Use Permit — Conceptual Layout Plan", prepared by Collins Engineering, with the latest revision date of June 2, 2020. To be in genera I accord with the Conceptual Plan, development must reflect the following major elements within the development essential to the design of the development and as described in the narrative and concept plan: a. Location and building footprint of the propowd expansion. b. The number of auto service bays. c. Mitigating landscaping within the stream bulfer, to the satisfaction of the County Engineer. d. Location and type of proposed landscaping tuffer.The landscaping buffer must be a mixture of deciduous and evergreen plantings, to the satisfaction of the Planning Director. e. Location of the parking areas, 2. The following restrictions to any new outdoor lightin apply: a. all fixtures must be full cutoff; b. lighting is li mtted to 20 foot-candles at the +ound; c. new outdoor lighting must be on a timer or motion sensor between the hours of 10 PM and 6 AM, 3, All mechanical equipment must be fully screened froorl. the view of adjacent properties and adjacent public streets. 4. Hours of operation of the service station are limited to within 7 AM - 9 PM, Monday through Saturday. Fuel sales are permitted 24 hours per day, LEGEND ROADS EXIS77NG CULVERT EARTH DITCH CULVERT DRIVEWAY CULVERT Q DROP INLET &STRUCTURE N0. BENCH MARK u + CURB CLEARING LIMITS CURB &GUTIER — — — — PROPOSED PAVEMENT SS VDOT STANDARD STOP SIGN EC-3A DITCH EXISTING CONTOUR 200 6" DEPTH OF EC-3A DITCH PROPOSED CONTOUR 20o EC-2 DITCH 240.55 PROPOSED SPOT ELEVA77ON TBC DENOTES TOP/BACK OF CURB 6" DEPTH OF EC-2 DITCH TAB DENOTES TOP OF BOX APPROVALS DATE DEPARTMENT OF COMMUNITY DEVELOPMENT ENGINEER ALBEMARLE COUNTY SERVICE AUTHORITY VIRGINIADEPARMENT OF TRANSPORTATION HEALTH DEPARTMENT SCOTT/R. CbLLINS7 Lie. No. 035791 � p 11/16/20 `�Q1 0 L` ZM M a1 N M N O W O O N w J F U I w w a Ln JOB NO. 202183 SCALE 1"=30' SHEET NO. 1 BOUNDARY CURVE TABLE Curve Length Radius Delta Tangent Chord Chord Bearing C1 206.21' 2701.49' 4'22'25" 103.16' 206.16' N 71'23'40" E C2 220.12' 1870.00' 6'44'39" 110.19' 219.99' N 68'19'42" W ---�—� — — — — — — � // 7 l l 1 1 I I l l y l I RADISF(3X) II I e I I I I I ASH I i I I I I I I I 81 ASH CN I I I I I I I ASH I I /10 ASH I I I 12_A H I I I I I I I � I ASH / 8 POP 12 ASH Ln 20 - 15 ASH®/ J EIL'L// // / / I EXISTIN I / PARADISE CRITICAL SL PIES 10Ica 10 AS /�� / / ,20 T PL ASHTMP 58A2-24C I / / 2 (RIVAINA WATER &SEWER j PARADISE AUTHORITY 1 ZONED: Cf � co /H 15 � / / l j 6 PARADISE e PARADISE / P Benchmark: 10 A / 7 iron Found IF / N:3908385.82 10 ASH / / / / E: 11455502.05 ���-- SHED // I 'PARADISE PARADISE(2X) Elev:539.11 / ,- �525_ )(ISTIN� E1 ISTING TREES E /O 20 ASH TMP 58A2-21 (PART 1) / LIMITSTO�REMAIN / CRITICAL SLOPE l / SR & DR, LLC 5 ASH DB 5139 PG 134 5 ASH / ZONED: C1 / /PARADISE 10 DBL 1.587 AC. �� --- / // I I I 8 PARADIS PARADISE SEPTIC / (-,�) \� IJ r / TANK LID / 8 ASH �V I`(I 18 ASH � EXISTING BUILDING I � I TO REMAIN�y� I 10 MAPLE *8/PARAPI \ SE i� EX. RESIDENTIAL //CLUSTER / 10 ASH` / / ' I TMP 58 OR -24 HOUSE / � � / � / 0 /, o EATON, LOUTS S OR SUSAN E / ' N #4272 / / / j� uj ZONED: RA �� VEN 10 A,, �� i < / 10 DBL / // Oo EENC E / < MAPLE / 18 ASO / PA DISE EXISTING TREES / i/10 AS 100 FLOO PLAIN " \ TO BE REMOVED, (TYPICAL) 8 DOGWOOD / k) /. \ so / TMP 58A2 20 / ��� ��Q \\ moo jam, \ \ =o / LENVIC, LLC I / / / / /PROPOSED / DB 3801 PG 750 I L it �� i/ / /�� / 11 / ��� \ \� FLOODPLAINE BAS ED ON MODELING. i / 0//j 15 PARADISE I I EXISTING TREE / N CAI, iiNu ycrvumu I TO REMAIN / / #4260 / \- TO REMAIN.' (TYPICAL) / �� // MW _y BOLLARD', 60.5' o. ' WOOD FENCE EXISTING CONCRETE\ /// RIP AP o GV. (&X) SLABS AND TANKS TO J / / M"W �' REMAIN CONCRETE UD �_ EXISTIN�s ��� /� _ - L. J / I PE ANENT RAINAGE INV=521.08 EXISTING SHRUBS / - ASPN tT GAS^SIGf♦•.;.•'\ / / EAS ENT I TO REMAIN \ 30' FRONT MAX. BUILDIN SETBACK R�LOCATED p \ DB 22 PG 43 HEADWALL ° 1 �^ 50 G EXISTING (2) GAS PUMPS �.•' MW ; S . '44"W / ExlsnlvG s' SIGN CANOPY _ / 1 — N01'27 O6"E VDOT R/W -- J/ — — — — — — 20.00' / / ---- - -\ - -`-- 10' FRONT MIN. BUILDING / POST & PARKING SETBACK —7 — PLANTING— iF 1 / — — NL BEDS MB r� ASPHALT — — — a EEX, CURD NTRANCE /I ✓ /� TO BE REMOVED — / / Lj w / / / I \ \ / DITCH — —\ �// / EXISTING AS /GUARDRAILS /1-0 \ \ — ------ — _--- ' / PAVEMENTWIT�IN Benchmark: / THIS AREA TO/BE— \ DI / i Nail Found / REMOVED. \ TOP=515.06 z U.S. ROUTE 250 / / �J EASTING N: 39080374 INV=510.46 O IVY ROAD EXISTING, ASPHALT J PAVEMENT E: 114551 7.87 — — PAVEMENT WITHIN Elev: 5T7.13 / / — — — — _ — — GRAPHIC SCALE \ \ ��PG THIS AREA TO BE ROAD PAINT / — / DB 231 PG 585 REMOVED. (STRIPING) / — — /--------__— zo o ro zo ao ea \ / / f _ \-------------- — — — — — ( IN FEET ) �`-------------� —-- _-- 1 inch = 20 ft. Lie. No. 035791,E 11/16/20 Lrti L` zM V \ (V — � z M � Q J z W � w Q ~ LL,I � U) z O J ~ Z Q Jp I� o z L90 0 z x z o U O ~ W X o H W zp Ul > z'. ZW cn �--� 34 U � X, ° w J U O O W ti F a w � JOB NO. 202183 SCALE 1"=20' SHEET NO. 2 0 NOTE., MECHANICAL EQUIPMENT SHALL BE LOCATED ON THE ROOFTOP OF THE PROPOSED BUILDING. VISIBILITYOFALL ME ANICAL EQUIPMENT SHALL BE ELIMINATED FROM THE E NCE CORRIDOR WITH THE USE OF PARAPET WALLS. SEEARCHITECTURAL PLANS. �01 �������� „ „�I I � 8 ASH I C 24 A®S®Hi/�j 8 ASH / �j�/ Q� ASH 15 �i%! z PARADISE 10 ASH / 10ASH a<- ,,a y G� ,15 POP 20 ASH (ZX) /8 ASS 0 ASH 10 ASH 8 POP 12 ASH /iii l 15 ASH / / / WELL 20 5 EXISTIN / / VO ASH PARADISE CRITICALSL PES EXISTING WELL RIVANNATMP W58A2 &SEWER I 10 0 ASH /' 20 T ASH / 12 / PARADISE AUTHORITY / cr) ZONED: Cl C 15 6 AD SE PARADISE(2 lot BenchmarkIron ound N 3908385.82 /10 ASH .41PARADISE0 8 E:11455502.05 / PARADISE(2X) / Elev: 539.11 EXISTING TMP 58A2-21 (PART 1) O / 20 ASH CRITICAL SLOPES /j DB 5139 PG 134 10 \ 5 ASH I ZONED: Cl PARADISE 5 ASH 10 DBL 1.587 AC. O 8 PARADIS PARADISE / / \Q� SEPTIC / TANK LID \ / / / 10 ASH / LOCATION APPROX. EXISTING POWER POLE WITH / LOCATION OF o STREET LIGHT TO REMAIN EX. RESIDENTIAL EXISTING SEPTIC DRAIN 7 / � , TMP 58A2-24 HOUSE / EATON, LOUIS S OR SUSAN E #4272 �` / ZONED: RA VEN E 0 ,< GPAVEL STORAIE/ ' o� / FENC PA DISE / �' SERVICE PARKING ,AREA 100 FLOG PLAIN / / I ' PROPOSED TRASH ; \ DUMPSTER ENCLOSURE SEE DETAIL, SHEET 6 / MIN. HEIGHT= 6' \ . STD ()PROPOSE�sbZ/o p p, \ EXISTING DRIVEWAY I \ PROPOSED io' VDOT ♦� TMP 58A2-20 TO RESIDENTIAL HOUSE 2CONCRETE cv CG-2 (TYP.) ti EXTERIOR BLDG D p :.�SO p• t \ LENVIC, LLC TO REMAIN APRON / DB 3801 PG 750 MOUNTED LIGHTS O / VD T ZONED: Cl IF Oz op / STD. CG-6 VAR. WIDTH ACCES CURB EASEMENT N73'50'25"W O _ ° ° 3 \ DB. PG. I 10.55' 12 TRP y N22'50'28"W APLE U P PROPOSED 6' CONCRETE 18 TYP. 16.58' SIDEWALK FLUSH WITH PAVEMENT r \ \QF OO zo PROPOSED 3,200 SF 07 v e \ \ I 26BUILDING EXPANSION I WITH 4 SERVICE BAYS TMP 58A2-20A Z PROPOSED BUMPER BLOCK 26' 9 UP Qw QQw JOSEPH W RICHMOND JT o / SV1u " - QO o TRUST FP SEE DETAIL, SHEET 6 �AC1�FTY i o 0 FP DB 4992 PG 686 ��= ASPHALT PAVING 18.8 o VDOT \ VARIAB I � � � c' r ASPHALT PAVING SEE DETAIL, y I � SHEET6 h,n' e SEE DETAIL, , �<v o SHEET6 B 4922 PG 5 J N" 1-STORY BRICK L DE j s 4 DE MILL/OVERLAY 00 O Oo EXISTING PAVEMENT IVY EXXON j (TYP.) DE AROUND BUILDING #4260 / SP0 \ I MW AND CANOPY, SEE FP -- ✓ \ DETAIL SHEET 6 \ / - i.• WOOD FENCE ��" ,.00 EXISTING POWER POLE WITH 0 GV. (1JX) /� �• ,. ' °O �o STREET LIGHT TO REMAIN \ 00 PROPOSED NEW JETBACK`' i t' BUILDIN PAVEMENT FOR 30' FRONT MAX. TAPER ENTRANCE, \ % (8) EX. LED LIGHTS' SEE DETAIL SHEET 6 Cj / MW UO FOR PAVEMENT t SIGN / CANOPY DESIGN EXISTING / N01'27'06"E - o — — — 20.00' VDOT R/W i - -- -- i — 10' FRONT MIN. BUILDING — — PROPOSED STOP SIGN PCST 16 &PARKING SETBACK 25' I t> o ASPHALT PLANTING F - - PROPO�F� STOP�I6N_ - BEDS - - -/ - - PROPOSEDIANDSCARE- ENTRANCE ISLAND- 38' 4' PROPOSED LOCATION OF RELOCATED EXXON - - - - ggo' SIGHT DISTANCE- - - - - - - - - - - ago' SIGHT DIS /' Benchmark: SIGN DI Ile Nail Found TOP=515.06 / Z U.S. ROUTE 250 EXISTING N:3908037.54 EXISTING GUARDRAIL INV=510.46 /'/ IVY ROAD J PAVEMENT E: 11455637.87 TO REMAIN. / 80' R/W ROAD PAINT Elev:517.13 ATTRTHE CSTARTE TO END OF THE DB 231 PG 585 (STRIPING) GUARDRAIL / (. / �VDOT STD. PROPOSED CG-2 (TYP.) `^\ MILL/OVERLAY AREA GV° ALONG IVY ROAD, UP SEE DETAIL SHEET 6 O S66'11'40"E UP IIF 162.74'^� O NOTE: 1. CONTRACTOR SHALL VERIFY ALL ROAD CONNECTIONS, INCLUDING RECENTLY CONSTRUCTED AREAS, VERTICALLY AND HORIZONTALLY PRIOR TO CONSTRUCTION AND SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES. 2. CONTRACTOR SHALL CONFIRM ALL UTILITY, DRAINAGE, AND ROAD CONNECTIONS, AND SHALL NOTIFY ENGINEER OF ANY TIE-IN ISSUES OR I DISCREPANCIES. 3. 1Q REPRESENTS ONE PROPOSED PARKING SPACE. 4. OVERHEAD WIRING OR OTHER OBSTRUCTIONS SHALL BE HIGHER THAN I 13'-6". 5. ALL PAVEMENT SHALL BE CAPABLE OF SUPPORTING FIRE APPARATUS ' WEIGHING 85,000 LBS. 6. CONTRACTOR SHALL ENSURE ALL ON -SITE UTILITIES, ABOVE AND BEL W GROUND, SERVICING ADJACENT PROPERTIES SHALL CONTINUE TO SERwICE THE ADJACENT PROPERTIES THROUGHOUT CONSTRUCTION AND UPON / COMPLETION OF THE PROJECT TO THE FULLEST EXTENT POSSIBLE. 7. CURB RADII SHOWN, REPRESENTED WITH AN 'R', DIMENSION THE FAC OF I / CURB. 8. ANY RETAINING WALLS GREATER THAN 3 FEET IN HEIGHT REQUIRE SEPARATE BUILDING PERMIT. WALLS EXCEEDING 4 FEET IN HEIGHT REQUIRE A STAMPED ENGINEERED DESIGN FOR THE WALLS SYSTEM. 9. BUILDINGS OR STRUCTURES BUILT BEFORE JANUARY 1, 1985 MUST] HAV AN ASBESTOS SURVEY PERFORMED IN ORDER TO APPLY FOR A / DEMOLITION PERMIT. ASBESTOS REMOVAL PERMITS ARE REQUIRED IF POSITIVE FOR SUCH. CONTACT VDOLI FOR ADDITIONAL REQUIRE ENTS IAND PERMITS FOR DEMOLITION PROJECTS. 10. ALL PRIVATE TRAVELWAYS SHALL BE OWNED AND MAINTAINED TH / OWNER. NO PUBLIC AGENCY, INCLUDING VDOT AND THE COLIN OF ALBEMARLE WILL BE RESPONSIBLE FOR MAINTAINING THE TRAV L ON THE PROPERTY. / SITE PLAN NOTES: = 1. SEE SHEET 2 FOR BOUNDARY DIMEN S, METES AND BOUND SURVEY / INFORMATION. 2. TRASH SHALL BE STORED & LLEC I IN T PSTER CONTA ER, SHOWN ON THIS / SHEET. 3. ALL BUILDINGS WILL H E A SLAB O RADE FOUNDATION. 4. CONTRACTOR SHALLRELOCATE DERGROUND AND OVERHEAD TILITIE AS NECESSARY. CONTRACTOR TO RK WITH TILITY COMPANY FOR THE DESI D LOC IONS. 5. CONTRACTOR SH LL REPL E THE PORTION OF THE EXISTIN ASPHA TRAIL DAMAGED FROM THE PROPOSED ONSTR TION. / 6. INDIVIDUAL SI NS WIL EQUIRE SIGN APPLICATION D SIGN D SIGNS WILL BE REQUIRED TO MEET STANDARD SIG GUIDELINES REGARDING SIZE SCALE PROPORTION RELATIVE TO / THE SIGN BP AN THE OVERALL BUILDING. 7. THE PROP SED E RANCE PAVEMENT SHALL AT H TH EXISTING PAVEMENT ON ROUTE 250 (IVY ROA ) AND S ALL TIE -INTO THE EXISTING IVY CAD AVEMENTATA MINIMUM OF i' FROM THEE D OF PA EMENT. I I I 1 %l SCOTT/R. CbLLINSZ_ Lie. No. 035791 � p 11/16/20 `�Q1 00*11 / / M / M d, fV S z N LU W N W EXISTING DRIVEWAY W J �ACCESS TO ADJACENT PROPERTIES TOREMAIN Z t Q I ---I _E WIDTH ACCESS ASEMENT 788 PG 841 841 PG 721 a 907 PG 509 / / x O O QRIP AP / X / CONCRETE UD I .�+ X J - PER ANENT RAINAGE INV=521.08 W w SIGN - �--r DB B22 PG 43 HEADWALL S28' '44"W /- _ _ _ - - - - \\ Ln 1 . 8'J — ------ / - -390' SIGHT DISTANCE - - - - - , ^ moo - ---- ------ -Il---------- --- --- 39oSDISTANCE 'IGHT � J W rol -,.,_VDOT STD. �, U CG-2 (TYP.) GUARDRAILS O O W J 800' TO NEAREST INTERSECTION (MORGANTOWN ROAD) \ S11'07'42"W 2.64' W O W a Ln JOB NO. 202183 HEADWALL GRAPHIC SCALE SCALE 20 0 10 20 40 80 1 //-201 SHEET NO. ( IN FEET ) 3 1 inch = 20 ft. Benchmark - Iron Iron Found N: 3908385.82 E:11455502.05 Elev:539.11 / I III I III I �15 ASH I II II II I I C� Q 8 ASH / 81 ASIH � OQ� 24 ASH 5 I I I PARADISE ASH 10 ASH O �QflI f10 ASH 12-A G� 20 'A H ;1� POP / ( ) 8 ASH 0 ASH 10 ASH I I 12 ASH I LO I 20 - 15 ASH / �L// / // / / / I I EXISTIN I 10 ASH PARADISE CRITICALL PES W EXISTIN E L1L TMP 58A2-24C O 10 / 0 ASH /f �J / ,20/T PL ASH 12 RIVANNA WATER & SEWER PARADISE AUTHORITY co ZONED: ui �I P ASH / u 15 O 6 PARADISE/ PARADISE X, q!, lot 10 A ASH / /10 8 SHED / / PARADISE PARADISE(2X) / �525— / �� EXISTING` NF i O <J �20 ASH / CRITICAL SLOP TMP 58A2-21 (PART 1) SR & DR, LLC - 15 ASH \ DB 5139 134 - - - ' / 100 I / O ZONED:: 15 ASH C1 / /PARADISE 10 DBL 1.587 AC /� / / / I I 8 PARADIS V PARADISE I / \ - / SEPTIC / I i / TMP 58A2-20 LENVIC, LLC DB 3801 PG 750 ZONED: C1 Ln o TANK LID/ / 10 ASH / / A�PROX. I A\ \ - LOCATION OF / A �" ✓ EXISTING SEP CDRAIN EX. RESIDENTIAL / � � TMP 58A2-24 �F IHOUSE / -/ o EATON, LOUIS S OR SUSAN E N #4272%'--- - !!!; u) ZONED: RA ulfil'tLn VEN E 10 4 i // I ' I FENC PA DISE II /��� I\ 100 FLOG PLAIN VAR. WIDTH SWM FACILITY & ACCESS 0�\� A ASEMENT � � DB.___ PG.--- V OT STD �s�o /0 1 06 �, A z PROPOSED CG-2 (TYP.) !•%Q / �\ oo. \ \ SWM FACILITY VDOT IF o / �� v v STD. VAR. WIDTH ACCESS \�\\\ IF\ CURB EASEMENT N73'50'25"W \ j \ // \ \ \ DB. PG. y� I 10.55' 12 TRP 0 / FFE= 6.55 \ L` APLE e N22'50'28"W \\ U P \ '� / / / \ / \ o \ X OX 16.58' \ I / S \ 6 , \ 0 PROPOSED 3,200 SF /S BUILDING EXPANSION a X N . WITH 4 SERVICE BAYS C \ s� F m9 \\ EXISTING DRIVEWAY TMP 58A2-20A UP w I w ACCESS TO ADJACENT z I ! � Q JOSEPH W RICHMOND Jr 'o, I / Q' Q w PROPERTIES TO REMAIN TRUST PROPOSED\2' \ oz , o FP \ - CURB CUTS WI X I\ NI�N DB 4992 PG 686 �m /> 188' o 0 0 \ RIPRAP DITCH I I I 45.0' e (TYP.) V OT \ \ VARIABLE WIDTH ACCESS FFE=516.55 B 492 PG EASEMENT DB 788 PG 841 /f 1-STORY BRICK / `dSj6 \ \ DB 841 PG 721 / IVY EXXON DB 907 PG 509 NOTE: MECHANICAL EQUIPMENT SHALL BE LOCATED ON THE ROOFTOP OF THE PROPOSED BUILDING. VISIBILITYOFALL ME�IANICAL EQUIPMENT SHALL BE ELIMINATED FROM THE E NCE CORRIDOR WITH THE USE OF PARAPET WALLS. SEEARCHITECTURAL PLANS. I / FP j Mw OLLARD' 6 .5' / WOOD FENCE / RIP AP o MWGV.(F§X) \ /// 7 a CONCRETE UD / / / !_ / / I'. r / ,� ® • i �� INV=521.08 _ _ PER ANENT RAINAGE �` • / / / EAS ENT -SIGN - / / r �' 2 43 HEADWALL I 30' FRONT MAX. BUILDINETBACK 2 PG / n \ DB / EXISTING 18" \ /, U d MW / �.•.•' // —, — — = __ = _ - i - / CULVERT TO BE G % �° S28 '44"W / EXTENDED WITH i _-_ - SIGN N01° T EXISTING '! CANOPY \ -- - --- / C�7 / / 1 $ //i / / VDOT STD. EW-1 2 06"E \ < C - J/ - S� - _ HEADWALL 20.00' / VDOT R/W - — / J 10' FRONT MIN. BUILDING - - & PARKING SETBACK - / up / - I J i I I I I PLANTING - I F / � k / - - -a - - I ASPHALT BEDS / / / o o / / CD n ENTRANCE / A j -� / / / � / VDOT STD. / / I I LC) ----- �u /� / CG-2 (TYP.) /GUARDRAILS - - - -- �� Benchmark: 51DI / i Nail Found - EXISTING GUARDRAIL TOP=515.06 Z U.S. ROUTE 250 EXISTING N: 3908037,54- ��� INV=510.46 0 IVY ROAD / ' ' J� PAVEMENT E: 11455¢37.87 TO REMAIN. ENTRANCE TO START _ �' - - - --80LR/V� - - - - ROAD PAINT Elev�5'C7.13 AT THE END OF THE- j - DB 231 PG 585 (STRIPING) / - GUARDRAIL - - - - - _ - - - - - / = *v 800' TO NEAREST 1 INTERSECTION ------------- ^--- ---- _------_---- -- VDOT STD. -- --__ ^- (MORGANTOWN ROAD) - --_ IIII II\�- � / — -- G 7 II �ih\\ 1j _--_ � � ,515- UP _ _ — \ - _ --'� �_- HEADWALL GRAPHIC SCALE A IIIII III ,-� 0 �� - S66'11'40"E UP ` — 20 0 10 20 40 162.74' O \ 7 42 W 2164 ( IN FEET ) 1 inch — 20 ft. 80 SCOTT/R. CbLLINSZ_ Lie. No. 035791 p 11/16/20 `�Q1 O O N w J H w W w a Ln JOB NO. 202183 SCALE 1"=20' SHEET NO. 4 RADISE(3X) PARADISE(2X) I I I I I I I I I I II II I I o I I II II II 1_ I I I I I 5 ASH 8 ASH I of trees o8 ASH 1 j I i� I i I I OQ� C 24 ASH 15 I �1y� PARADISE 10 ASH ASH I 0 ASH 2 A H i 1l 20 ASH ;15 POP / (2X) 8 ASH 10 ASH 0 ASH railq/�/ / �� 8 POP / 2 ASH �� ELL / ��, ;�� 20 - 15 ASH / J / I / // / / / / / 15 / EXISTIN I 10 ASH PARADISE r I CRITICALSL PES W g / ASH l I / / / / / TMP 58A2-24C p 10 / / 10 ASH / ,20 PL ASH / 2 J / / 12 I I RIVANNA WATER &SEWER / j / /PARADISE I AUTHORITY I CIO ZONED: Cf N // j // // ASH 15 6 P aRADISE / PARADISE IF /10 ASH SHED // // jV/ /PARADISE PARADISE(2X) I 5nI06 Page I of / r- �525 / PROPOSED T.R�E EXISTING �O TMP 58A2-21 (PART 1) P/1%TECTION' FENCEJI/////�20 ASH , / CRITICAL SLOPES SR & DR, LLC / ✓/i DB 5139 PG 134 10 I 15 �H ASH � ZONED: CI / /'PARADIS I I PTO DEL 1.587 AC. - - / / I I 8 PARADI PARADISE / SEPTIC\100, / / O- �I II / TANK LIDI/ /KIDI`I I (1) A I if Ili I EX RESIDENTIAL SCHEDULE TOTALSITE SYM BOTANICAL COMMON NAME SIZE CANOPY (sf QUANTITY1 COVERAGE (sf) TREES BN I BETULA NIGRA I RIVER BIRCH 10'-12' ht. 1 397 1 1 1 397 PA IPLATANUSACERIFOLIA I LONDON PLAN ETREE 21/2"cal. 1 422 1 2 1 844 QP IQUERCUS PALUSTRIS I PIN OAK 31/2" cal. 1 471 1 5 1 ,355 JUNDERSTORY TREES G AMALANCHIER x GRANDIFLORA SERVICEBERRY 6-Tht. 1 130 1 1 1 130 CIF CORNUS FLORIDA IDOGWOOD 6-7'ht. 1 124 1 2 1 248 PY PRUNUSYEDOENSIS IYOSHINOCHERRY 6-7'ht. 1 99 1 5 1 495 EVERGREEN TREES IN ILEX x'NELUE R STEVENS' I NELLIE R STEVENS HOLLY V-71 1 44 1 12 1 2,376 MG I MAGNOLIA GRAN DIFLORA LITTLE GEM' I LITTLE GEM MAGNOLIA 6'-8' ht. 1 82 1 10 1 2,214 SHRUBS B ABELIAGRANDIFLORA GLOSSYABELIA 24"1min 14 8 420 S CORN USSERICEA RED TWIG DOGWOOD 18"1min 72 8 576 IIV ILEX CORNUTA CHINESE HOLLY 24" 1 min 14 8 112 ITEA VIRGINICA'HENRY'S GARNET' HENRY'S GARNETSWEETSPIRE 18"1min 1 64 8 512 EXISTING TREE CANOPY Existing Tree Canopy 14,190 TOTAL CANOPY 24,869 CALCULATIONS: z EXISTING TREE CANOPY: TOTAL TREE CANOPY ON THE PROPERTY: 14,190 SF 24,869 SF TOTAL PARKING LOT TREES REQUIRED: PARKING SPACES: 29 # TREES REQ'D (1 / 10) 3 TREES PROPOSED: 5 PAVED PARKING & VEHICULAR CIRCULATION AREA:28,480 SF SF PLANTING SPACE REQUIRED (5%): 1,425 SF SF PLANTING SPACE PROVIDED: 1,920 SF STREET TREES: TOTAL LINEAR FOOTAGE OF PROPERTY FRONTAGE: 190 LF TOTAL STREET TREES REQUIRED (1 TREE PER 40') = 5 TREES TOTAL STREET TREES PROVIDED = 5 TREES I / 1 l /_� I I TMP 58A2-24 �F HOUSE / / / / o EATON, LOUIS S OR SUSAN I " N #4272 , / / / / i' / / ZONED: RA ,ItU n VEN E 10 / I FENC PA DISE ✓< // // / 100 FLOO PLAIN A \ \ / \ I , I o CIF �s /tea ��oo° A A o V II II II F �z (2) MG \ \ C �\ \ \ \ o / / /� + 2) P + I N73'50'25"W \ / / FFE=S 6.55 A ` / I 10.55' �12 ITT / / / 2) IV APLE ' « \ N22.50'28"W ��\ " UP A / //o + OO 1 BN 16.58' \ I PROPOSED 3,26o SIF s O 3 1C \ _ \ / BUILDING EXPANSION j °� \ o I / WITH 4 SERVICE BAYS } V Q • A VA I (2) MG TMP 58A2-20A Z¢w'O JOSEPH W RICHMOND Jr 4 F \ w o w I, TRUST - P \ Jo 0 + (s) Iv VA Source: Va. DSWC Plate 3.38-2 I DB 4992 PG 686 m /) ❑18.8' o P❑ T \ N w 3, Conservation Plan Notes: I // 45.0' / l FFE=516.55 49 PG 5 �\ \ 1.ALL TREES TO BE PRESERVED AND PROTECTED SHALL BE MARKED WITH N // 1-STORY BRICK / ' 6 ,� \\ PAINT OR RIBBON AT A HEIGHT CLEARLY VISIBLE TO EQUIPMENT +I OPERATORS. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE / IVY EXXON (6) MG TREE MARKING HAS BEEN INSTALLED BY THE CONTRACTOR AND / #4260 / « �•'�j \ \ INSPECTED AND APPROVED BY THE COUNTY ENGINEERING DEPARTMENT. I / (2) CS MW 2. HEAVY EQUIPMENT, VEHICULAR TRAFFIC, AND THE STORAGE OF + FP / \ I CONSTRUCTION MATERIALS AND SOIL SHALL NOT BE PERMITTED WITHIN I ---� OLLARD� 6 .5' / p11 , _ -c\,1 \ III THE OUTSIDE DRIPLINE OF TREES TO BE PRESERVED AND PROTECTED. WOOD FENCE �• /� / « f 3. TEMPORARY EROSION CONTROL MEASURED AND/OR PERMANENT STORMWATER MANAGEMENT FACILITIES LOCATIONS SHALL BE { COORDINATED SUCH THAT THEY SHALL NOT ADVERSELY AFFECT TREES (3) IN ' a f >.'e'�J k.•� TO BE PRESERVED AND PROTECTED. 4. FIRES SHALL NOT BE PERMITTED WITHIN 100 FEET OF THE OUTSIDE -G= ,� • /..\\ i {f ` DRIPLINE OF TREES TO BE PRESERVED AND PROTECTED. 5. TOXIC MATERIALS SHALL NOT BE STORED WITHIN 100 FEET OF THE G a• - IMW '_' OUTSIDE DRIPLINE OF TREES TO BE PRESERVED AND PROTECTED. SIGN CANOPY 6. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE TREE NOl-2T06"E \ , /f PROTECTIVE FENCING HAS BEEN INSTALLED BY THE CONTRACTOR AND 20.00' INSPECTED AND APPROVED BY THE COUNTY ENGINEERING DEPARTMENT. -- - / 10' FRONT MIN. BUILDING _ - / 5 CK i � ° d I Y - - � 7. WHEN TRENCHING FOR ANY KIND OF UNDERGROUND WATER, SEWER, - , - - - - - &PARKING CS ELECTRICAL, CABLE, TELEPHONE, OR OTHER UTILITY SERVICE IS - - County of Albemarle Conservation Plan Checklist- To be placed on Landscape Plans (Handbook, TIP III-284-111-297 for complete specifications) 1. The to llow Ina Items stall he shown on the plam El Trees to'oe oavc6, EI Lindnofelearing(outaidedriphneofinestobesaved); EI Locationand type ofprotective Penang, Grade changes requiring tree wells or walb; Proposed trenching or tuanding beyond the India of Blearing. 2. Markus: ZI All trees to be saved shall be marked with print or ribbon at a height clearly visible to equipment operators. EI No grading shall begin until the lace marking has been inspected and approved by a County Inspector. 3. PreLon nairtion Conference: ZI Tree preservation and protection nommms shall be reviewed with the contractor on site. 4. Eanioment Operation and Storaee: LI Heavy equipment, vehicular traRcand storage ofeoastmction materialsinchriing soil shall nolbepermitted within the driphnes to be saved. 6. son Ertl and Stormwaeer Dennis. Devices: U Such devices shall not adversely affect trees m be saved. 6. trial E1 Fires are not permitted within 100 feet ofthe dripline of trees to be saved. 7. Took Materials: ® Toxic materials shall not be stored within 100 feet of the dripline oftrees to be saved. S. Protective Fencine: EI Trees to be retained within 40 feet of a proposed building or grading activity shall be protected by fencing. ZI Fendng shall be in place and shall be inspected and approved by a County Inspectorprier to grading ar construction 9. Troe Wells: ® When the ground level must be raised within the dripline of atese to be saved, a was well shall be provided and a construction de submitted for approval. 10. Tree Walls: EI When the ground level most be lowered within the dripline a tree m be saved, ones wall shall be provided; and a censtmction dets submitted for approval. 11. Urnchim, a ad T anneline: LI. When trenching is required Milan the limits of clearing, it shall be done as far away from the tanks oftrees as possible. Traveling under a large two shall be considered as an altemative when it is anticipated that necessary trenching will destroy feeder roots. 12. Clete W Protective fencing shall be the last items removed during the final cleanup. 13. Damaeed Trcer: ® Dan Laces shall be treated immediately by pruning, fertilicim m or othcuradbods recommended by atree specialist. NOTE: IT IS EDEVELOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATIO REQUIREMENTS. 11/16/2020 'Alt CONTRACT PURCHASER SIGNATURE (DATE) 1992 FENCING AND ARMORING I I BRA LINE� I SNOW FENCE 'IIIIIIII��II�II�I,llill�ill,!It,, . �..n�ual'IIIIIIIIIIIIII I�► e iOWM" :III Landscape Notes NOTES• 1. ALL TREES TO BE PLANTED SHALL MEET THE SPECIFICATIONS OF THE AMERICAN ASSOCIATION OF NURSERYMEN. THE PLANTING OF TREES SHALL BE DONE IN ACCORDANCE WITH EITHER THE STANDARDIZED LANDSCAPE SPECIFICATIONS JOINTLY ADOPTED BY THE VIRGINIA NURSERYMENS ASSOCIATON, THE VIRGINIA SOCIETY OF LANDSCAPE DESIGNERS AND THE VIRGINIA CHAPTER OF THE AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS, OR THE ROAD AND BRIDGE SPECIFICATONS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION. 2. ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH, AND BE MAINTAINED AT MATURE HEIGHT- THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. 3. THE LANDSCAPING PLANTS AND 7REES ADJACENT TO THE SIGHT DISTANCE TRIANGLE WILL NEED TO BE MAINTAINED IN THE AREA BETWEEN 2' AND 7' ABOVE GROUND AS CLEAR ZONE TO PRESERVE SIGHT LINES AND ACCOMMODATE PEDESTRIANS DOUBLE STRAND #12 GAUGE WIRE WITH RUBBER HOSE & TURNBUCKLES 2"x2" HARDWOOD STAKE CUT & REMOVE BURLAP FROM TOP 1/3 OF BALL AS SHOWN SCARIFY SUBSOIL TO 4" MIN DEPTH MULCH SAUCER FINISHED GRADE TREES UP TO 4 CAL SHALL BE STAKED. TREES 4" CAL OR LARGER SHALL BE GUYED WITH 3 EQUALLY SPACED TWISTED, #12 GAUGE WIRE WITH HOSE AND TURNBUCKLES LOOP HOSE AROUND TRUNK ABOVE BRANCHES AS SHOWN, FLAG WIRES WITH COURV£Y TAPE. REFER TO SPECS FOR ADDITIONAL INFORMATION. AMENDED SOIL MIX COMPACTED SUBGRADE Tree Planting and Staking Detail Not To Scale Evergreen Tree Planting Detail Not To Scale TREES UP TO 4" CAL. SHALL BE STAKED WITH 2 2"x2" HARDWOOD STAKES. TREES OF 4" CAL. OR LARGER SHALL BE GUYED WITH 3 EQUALLY SPACED, TWISTED, AND TURNBUCKLES. LOOP HOSE AROUND TRUNK. FLAG WIRES WITH COURWY TAPE. REFER TO SPECIFICATIONS FOR FURTHER INFORMADON GUYWIRES WITH RUBBER HOSE AND TURNBUCKLES 2/3 UP TREE 2"x2" HARDWOOD STAKES, AHGN TOP OF STAKES MULCH SAUCER AMENDED SOIL MIX CUT AND REMOVE BURLAP FROM TOP 1/3 OF BALL AS SHOWN SCARIFY SUBSOIL TO 4" MIN. DEPTH COMPACTED SUBGRADE / I RIP AP CONCRETE UD PER ANENT RAINAGE INV=521.08 EAS ENT SIGN - DB 22 PG 43 HEADWALL S28° '44"W i NECESSARY WITHIN THE LIMITS OF TREE PROTECTION OR BEYOND THE - - J LIMITS OF CLEARING, THE SEPARATION FROM THE TRUNKS OF TREES M� \ PLANTING SHALL BE MAXIMIZED TO THE FURTHEST EXTENT POSSIBLE. TUNNELING ASPHALT ASPHALT I BEDS \ t - k e p / / I I I I SHALL BE REQUIRED WHEN DEEMED, BY THE COUNTY ENGINEER, THAT TRENCHING WILL SIGNIFICANTLY DAMAGE FEEDER ROOTS OF TREES TO ENTRANCE // BE PRESERVED AND PROTECTED. I 8. ANY DAMAGE TO THE CROWN, TRUNK, OR ROOT SYSTEM OF ANY TREE / TO BE PRESERVED AND PROTECTED SHALL BE REPAIRED IMMEDIATELY, (5) PY / /GUARDRAILS IN ACCORDANCE WITH THE PRACTICES IN THE EROSION AND SEDIMENT -- ----- -----\ / / / / CONTROL HANDBOOK. CARE FOR SERIOUS INJURIES SHALL BE - / Benchmark: PRESCRIBED BY A PROFESSIONAL FORESTER OR TREE SPECIALIST. \ - -- J DI (5) Nail Found 9. SOILS WHICH HAVE BEEN COMPACTED, OVER THE ROOT ZONES OF \ ` TOP=515.06 S U.S. ROUTE 250 (8) AB EXISTING N: 3908037y4 TREES TO BE PRESERVED AND PROTECTED, SHALL BE AERATED BY S% g, \ INV=510.46 o IVY ROAD / ' J / / PAVEMENT E: 11455¢37.87 PUNCHING HOLES WITH AN IRON BAR EVERY 18" OVER THE ROOT _ ` / / - - - - - (5) I Elev:,517.13 / / _ _ _ _ _ - GRAPHIC SCALE ZONE. THE BAR SHALL BE DRIVEN 12" DEEP AND MOVED BACK AND - - \ - A01"I - - - - J ROAD PAINT - -_- _ FORTH IN EACH HOLE UNTIL SOIL IS LOOSENED. \ / - DB 231 PG 585 (STRIPING) / - - - - - - - - - - - - - 20 0 10 20 40 80 10. TREE PROTECTIVE MEASURES SHALL BE THE LAST OF THE TEMPORARY EROSION CONTROL PLAN MEASURES REMOVED DURING THE / J _ _ - - - - FINAL CLEAN-UP. - / - - - - - - --- ------- ---_ ( IN FEET ) \ `��-- ---- 1 inch = 20 ft. _- ------ `�------- ��---- --- %l SCOTT/R. C1!ILLINS7 Lie. No. 035l p 11/16/20 `�Q1 z O � U Z w M 00a Z J z W W W CD W N o 0 L` ZM M N - � z M � J CN a W N w N W (n Z� w J Q 1� Z L9z z z x z U O U W X z X W Q (~ J W o V O O N w J H I w CL w � JOB NO. 202183 SCALE 111=20' SHEET NO. 5 A PERMISSIBLE COMET. JOINT A EJ -TRUNCATE[ SEE SHEET TANGENT PLAN 2'-0" I W-D" FOR DETAILS STD. CC-2 BACK OF CUR 1 12 :1 1 46A I 20'1 4:1 wo 2'MIN. SECTION A -A NOTE: FOR GENERAL NOTES ON THE DETECTABLE WARNING SURFACE. SEE SHEET IOF 4. TYPE C PARALLEL & PERPENDICULAR APPLICATION ROADWAY GRADE IN PERCENT MINIMUM RAMP LENGTH IN FEET 4" CURB 6" CURB 0 2 4 2 5 2 3 5 3 3 6 4 4 B 5 5 0 6 7 4 7 3 5 8 15 15 NOTE' THE REQUIRED LENGTH OF A PARALLEL RAMP IS LIMITED TO 15 FEET, REGARDLESS OF THE SLOPE. o u - 3 o � rc o= �CROSSWALK� TYPICAL PLACEMENT AT INTERSECTION WITH BUFFER STRIP THE SELECTION OF CURB TYPE AND THE CONFIGURATION OF THE UTILITY STRIP MAY VARY TO MEET EXISTING FIELD CONDITIONS AND ROADWAY GEOMETRICS PROVIDING THE OIMNSIONS AND SLOPES ME AS NOTED. a �,1 MAx 2:1 M Y�� 2' MIN AT X . 2" HIGHER THAN F EDGE OF PAVEMENT AT)X.T",.SAME AS TOP OF CURB THIS COMBINED (PARALLEL 6 PERPENDICULAR) DESIGN FOR ALTERATIONS CAN BE USED WITH ADJOINING BUFFER STRIP. LANDING AT BOTTOM OF TWO SLOPING SIDES WITH 60" X 50" MIN. DIMENSIONS THE SHORT PERPENDICULAR RUN TO THE STREET CAN BE PROTECTED BY A LANDSCAPED SETBACK OR CONNECTED TO THE SIDEWALK WITH A WARPED SURFACE. CG-12 DETECTABLE WARNING SURFACE REV. 7/05 TYPE C (PARALLEL & PERPENDICULAR) APPLICATION 203.07 VIRGINIA DEPARTMENT OF TRANSPORTATION NOTES: 1. THIS REM MAY BE PRECAST OR CAST IN PLACE. 2. CONCRETE TO BE CLASS A3 F CAST IN RACE, 4000 PSI IF PRECAST. 3. CURB HAVING A RADIUS OF 300 FEET OR LESS (ALONG FACE OF CURB) WILL BE PAD FOR AS RA MIL CURB. - 4. THE DEPTH OF CURB MAY BE REDUCED AS MUCH AS 3" ITS" DEPTH) OR INCREASED AS MUCH AS 3" (21" DEPTH) IN ORDER THAT THE BOTTOM OF CURB WILL COINCIDE WITH THE TOP OF A COURSE OF THE PAVEMENT SUBSTRUCTURE. OTHERWSE THE DEPTH IS TO BE 15" AS SHOWN. v NO ADJUSfAENT N THE PRICE BID IS TO BE MADE FOR A DECREASE OR AN INCREASE N DEPTH. g 5. CG-2 IS TO BE USED ON ROADWAYS MEETING THE REQUIREMENTS FOR CG-B AS SHOWN N APPENDIX A OF THE VDOT ROAD DESIGN MANUAL, IN THE SECTION ON CS URBAN STANDARDS. ,;A• 2" RADIUS D.' o Y G.�' G. • e. . SURFU :� �D :�•, BASE DAD B" ACCEPTABLE ALTERNATIVE IF CURB IS EXTRUDED ERENCE STANDARD 6" CURB DS 502 VIRGINIA DEPARTMENT OF TRANSPORTATION WP-2 4" R CII G!c ROAD AND BRIDGE STANDARDS REVISION DATE SHEET 1 OF 1 201.01 EDGE EXING PAVEMENT I I DETERMINED IN FIELD) TACT( COAT THE PROPOSED CONSTRUCTION JOINT EXISTING ASPHALT LAYERS - PROPOSED ASPHALT LAYERS EXISTING SUBBASE ---- PROPOSED -------- SUBBASE COMPACTED SUBGRADE CONSTRUCTION JOINT DETAIL ® REMOVE EXISTING ASPHALT LAYERS TO EXISTING SUBBASE AND REPLACE WITH PROPOSED ASPHALT WIDENING LAYERS ® PROPOSED MINIMUM 11/, INCH THICK ASPHALT SURFACE COURSE (SEE NOTE 5) x MINIMUM 12 INCHES. OR GREATER AS NECESSARY TO ABUT THE FULL THICKNESS OF EXISTING ASPHALT LAYERS AS DETERMINED BY CORES (SEE NOTE 3) NOTES: 1. ASPHALT PAVEMENT WIDENING SHALL HAVE A PAVEMENT DESIGN N ACCORDANCE WITH CURRENT VDOT PROCEDURES AND BE APPROVED BY THE ENGINEER. 2. THE PAVEMENT DESIGN FOR ASPHALT PAVEMENT WIDENING SHALL MEET OR EXCEED THE DEPTHS AND TYPES OF THE LAYERS OF EXISTING PAVEMENT. SUBSURFACE DRAINAGE OF THE EXISTING AND PROPOSED PAVEMENT SHALL BE ADDRESSED IN THE PAVEMENT DESIGN. 3. A MINIMUM OF THREE CORES SHALL BE TAKEN ALONG THE CENTER OF THE ADJACENT TRAVEL LANE TO DETERMINE THE TYPE AND THICKNESS OF EXISTING PAVEMENT LAYERS. THESE CORES SHALL BE SPACED NO MORE THAN 500 FEET APART. 4. THE ADJACENT TRAVEL LANE SHALL BE MLLED A MINIMUM DEPTH OF 1 I/. INCHES AND REPLACED WITH AN ASPHALT SURFACE COURSE TO MATCH THE PROPOSED PAVEMENT WIDENING SURFACE COURSE. UNLESS WAVED BY TFE ENGINEER. 5. THE ENGINEER MAY REQUIRE THE WILLING DEPTH OF THE EXISTING PAVEMENT TO BE ADJUSTED TO ACHIEVE AN ACCEPTABLE PAVMENT CROSS -SLOPE AND EFFECTIVE SURFACE DRAINAGE. 6. EXISTING PAVEMENT MARKINGS AND MARKERS WITHIN THE PROJECT LIMITS SHALL BE RESTORED SUBJECT TO THE APPROVAL OF THE ENGINEER. 7. FINAL TRANSVERSE PAVEMENT TIE-IN SHALL CONFORM TO THE REQUIREMENTS OF SECTION 315.05(c) OF THE SPECIFICATIONS EXCEPT THAT ALL JOINTS AT TIE-IN LOCATIONS SHALL BE TESTED USING A 10 FOOT STRAIGHTEDGE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 315,01 OF THE SPECIFICATIONS. ASPHALT PAVEMENT WIDENING SPECIFICATION REFERENCE kRE11,1,/07 FOR WIDENING SUBJECT TO TRAFFIC 305 VIRGINIA DEPARTMENT OF TRANSPORTATION 315 ALBEMARLE COUNTY GENERAL NOTES FOR SITE PLANS: PA VEMEN T 1. AN ACTUAL COPY OF THE CBR REPORT IS TO BE SUBMITTED PRIOR TO THE PLACEMENT OF THE AGGREGATE BASE MATERIAL. IF THE SSV VALUES ARE LESS THAN 10, THE DEVELOPER WILL BE REQUIRED TO SUBMIT FOR ENGINEERS APPROVAL THE PROPOSED METHOD OF CORRECTION. 2. SUBGRADE MUST BE APPROVED BY THE ENGINEER FOR GRADE, TEMPLATE AND COMPACTION BEFORE BASE IS PLACED. 3. TEST REPORTS ON SELECT MATERIALS MUST BE SUBMITTED SHOWING THE MATERIAL MEETS REQUIRED GRADATION FOR TYPE 1, Il, OR N PRIOR TO PLACING AGGREGATE BASE. 4. THE REQUIREMENTS TO PUGMILL AGGREGATE BASE WILL BE WAIVED IN THE EVENT THAT THE SURFACE COURSE IS BEGINNING AT THE COMPLETION OF THE INSTALLATION OF THE AGGREGATE BASE. IN THE EVENT THAT THE SURFACE COURSE IS APPLIED PRIOR TO 60 DAYS, THE PUGMILL REQUIREMENT WILL APPLY 5. THE USE OF AN AGGREGATE SPREADER IS REQUIRED WHEN PLACING AGGREGATE BASE. 6. BASE MUST BE APPROVED BY ENGINEER FOR DEPTH, TEMPLATE, AND COMPACTION BEFORE SURFACE TREATMENT IS APPLIED. 7. PRIME COAT MUST BE APPLIED TO BASE MATERIAL PRIOR TO PLACEMENT OF ASPHALT (PRIME COAT RC-250 @ 0.3 GAL./SQ. YD.). 8. BITUMINOUS SURFACE TO BE APPLIED IN ACCORDANCE WITH CURRENT VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS. 9. ENCROACHMENT POSTS, WALLS, SIGNS, OR SIMILAR ORNAMENTAL STRUCTURES THAT DO NOT ENHANCE A ROADWAYS CAPACITY OR TRAFFIC SAFETY, SHALL NOT BE PERMITTED WITHIN THE RIGHT OF WAY. ONLY THOSE STRUCTURES SPECIFICALLY AUTHORIZED BY PERMIT ISSUED BY VIRGINIA DEPARTMENT OF TRANSPORTATION MAY BE LOCATED WITHIN THE STREETS RIGHT OF WAY. GRADING 1. THE LATEST EDITION OF THE ROAD & BRIDGE SPECIFICATIONS, THE ROAD & BRIDGE STANDARDS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS SHALL GOVERN THE MATERIAL AND CONSTRUCTION METHODS OF THIS PROJECT. 2. WHERE UNSUITABLE MATERIAL IS ENCOUNTERED IN THE ROADWAY, IT SHALL BE REMOVED FROM THE ENTIRE ROAD RIGHT OF WAY WIDTH AND REPLACED WHERE NECESSARY WITH SUITABLE MATERIAL TO THE SATISFACTION OF THE ENGINEER. J. ALL GROWTH OF TREES AND VEGETATION SHALL BE CLEARED AND GRUBBED FOR THE ENTIRE EASEMENT. OTHER TREES AND VEGETATION WHICH OBSTRUCT SIGHT DISTANCES AT ROAD INTERSECTIONS SHALL BE REMOVED. 4. ALL VEGETATION AND OVERBURDEN TO BE REMOVED FROM SHOULDER TO SHOULDER PRIOR TO THE CONSTRUCTION OF THE SUBGRADE. DRAINAGE 7. ALL PIPE CULVERTS, EXCEPT PRIVATE ENTRANCES, SHOWN HEREON ARE TO BE RCP WITH A MINIMUM COVER OF ONE (1) FOOT OR AN APPROVED VDOT PIPE MATERIAL. 2. STANDARD UNDERDRAINS (CD-7 OR CD-2 OR UD-4"S) TO BE PROVIDED AS INDICATED ON THE PLANS, OR WHERE FIELD CONDITIONS INDICA TE. J. ALL DRIVEWAY ENTRANCE PIPES SHALL BE A MINIMUM OF TWENTY (20) FEET IN LENGTH AND HAVE A MINIMUM DIAMETER OF FIFTEEN (15) INCHES AND SHALL BE PLACED IN ACCORDANCE WITH THE VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS UNLESS OTHERWISE NOTED ON PLANS. 4. ALL DRAINAGE EASEMENT SHALL BE CLEARED AND GRADED TO THE SATISFACTION OF THE ENGINEER. DRAINAGE EASEMENTS SHALL EXTEND TO A POINT DEEMED AS NATURAL WATER COURSE. ALBEMARLE COUNTY GENERAL CONSTRUCTION NOTES FOR SITE PLANS 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF 7RANSPORTA77ON (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR 774E REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL PAVING, DRAINAGE RELATED MA7ER/ALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIF/CA77ONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. J. EROSION AND SILTAT70N CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED AND MULCHED. THE MAXIMUM ALLOWABLE SLOPE IS 2: 7 (HORIZONTAL: VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3:7 OR BETTER ARE TO BE ACHIEVED. 5. PAVED, RIP -RAP OR STABILIZATION MAT LINED DITCH MAY BE REQUIRED WHEN IN THE OPINION OF THE ALBEMARLE COUNTY DIRECTOR OF ENGINEERING, OR THE DIRECTOR=S DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 6. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 7. UNLESS OTHERWISE NOTED ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE - CLASS Ill. 8. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). NOTE: CONCRETE (VARIABLE WIDTH) SHALL BE 3000 PSI (5' MIN.) AT 28 DAYS OR STRONGER. 4" CONC. 4" 21-A STONE BASE CONCRETE SIDEWALK NO SCALE 2" SM-9.5 SURFACE COURSE 3" BM-25 INTERMEDIATE COURSE BASE COURSE COMPACTED SUBGRADE ASPHALT PAVING - TRAVELWAYS NO SCALE 2" SM-9.5 SURFACE COURSE 8' 21-A BASE COURSE COMPACTED SUBGRADE ASPHALT PAVING - PARKING LOT NO SCALE PROPOSED 1" SM-9.5 OVERLAY EXISTING PAVEMENT EX. STONE \ /\, / / SUBBASE \�\\///// COMPACTED SUBGRADE ASPHALT PAVING - MILL/OVERLAY NO SCALE 12" REFLECTIVE ALUMINUM RESERVED LEGEND AND BORDER - GREEN PARKING Itz WHITE SYMBOL ON BLUE BACKGROUND BACKGROUND - ` WHITE M TYPICAL AT ALL HANDICAP SPACES THIS SIGN TYPICAL AT ALL "VAN VAN ACCESSIBLE" PARKING SPACES ACCESSIBLE PENALTY SIGN WITH WORDING AS REQUIRED BY STATE OR LOCAL LAW L z GALVANIZED "U" CHANNEL POST dN �o d LJ O � w d VDOT A3 GENERAL N CONCRETE ow o TOPSOIL AND SEED J D / N 4„ MIN. HANDICAP PARKING SIGN DETAIL NOT TO SCALE ONE AT EACH HANDICAP SPACE. WHERE HANDICAP SPACES FACE EACH OTHER WITHOUT WALKWAY, THERE SHALL BE ONE POST WITH SIGNS MOUNTED BOTH SIDES Concrete Bumper Block I Concrete: 4,000 P. S.1, Vibrated • Reinforcing 2 #4 Rebars, 1.5" from bottom" • 72" long, 5" high, 4" wide top, 7&guot wide bottom • (Not dawn to scale) I-4"I 12" �I 6» I II v IL- 1211 -�UI 314" holes ;I Mtt 12'x25' CONIC. MIN. 12'x20' CONCRETE DUMPSTER PAD LOADING SPACE 7" THICK - 3000 PSI CONCRETE 4 �6" COMPACTED z1B STONE BASE 1'nAl/'OC7_C I /1 A FIIAI/' 01D A /`C nCTA ll NO SCALE HANDICAP SIGN LOCATION (VAN) FLUSH SIDEWALK FACE OVA OF CURB BUMPER BLOCK PAIN PER VDOT PAINTED SPEC. TRIPE YPICAL) ACCESSIBLE SPACE HANDICAP SPACE DETAIL NO SCALE NOTE HC PARKING SPACE & ACCESSIBLE ROUTES SHALL BE COMPLIANT w/ ALL CURRENT ADA STANDARDS & LOCAL/STATE REQUIREMENTS NOTE: ACCESSIBLE PARKING SPACES, ACCESS ISLES, AND ACCESSIBLE ROUTES SHALL BE INSTALLED IN ACCORDANCE WITH ICC ANSI i17.i-09. 13'-0" 4'-0"5"-O" -O 1'-0" (TYP.) STEEL BOLLARD (INTERIOR) (TYP.) (SEE DETAIL THIS SHEET) 6,-O" Ica /R (TYP.) I I 1'-0" (TYP.) $ B PAINTED BRICK ENCLOSURE TO MATCH o A PROPOSED BUILDING (8" WIDTH X N 7'-0" HEIGHT) o A a 4 STEEL BOLLARD (EXTERIOR) N O 5° (TYP.) (SEE DETAIL THIS SHEET) INOODEN�DOCRS DUMPSTER GATE (SEE DETAIL THIS SHEET) 45' CHAMFER 13'-O" F\ ,I DENOTES 8 C.Y. DUMPSTER 1� 1 6 -0 (L) X 5 -6 (W) X 6 -8 (H) LAYOUT (2 PER DUMPSTER PAD) NOTE: BROOM FINISH 67x6" W2.1xW2.1 WELDED WIRE REINFORCEMENT C2») / r 7" CLASS A3 CONIC. t rz, 7" 21A STONE j\�j\\j j\\�j\\j j\\ /\<j -COMPACTED SUBBASE DETAIL - CONCRETE DUMPSTER PAD NOTE : CONTRACTOR TO VERIFY WITH ON -SITE GEOTECHNICAL ENGINEER FOR FINAL CONCRETE DETAILS. Z 0 ti Q C� 1x6x6 TREA7s26 BOARDS �BOLTED TO IRON FRAME STEEL BOLLARD (EXTERIOR) (TYP.) (SE o DETAIL THIS SHEET) N CE :W. 7 a A 2x2x3/16 CANE BOOT ANGLE IRON FRAME DETAIL DUMPSTER GATE DETAIL N DUMPSTER AREA NOT TO SCALE SCOTT/R. C>1LLINS'Z H--R Lic. No. 035791,E A 11/16/204i w AN W �1 LU I, -^I V / J Q J ~� LU I 0 z 66 0 LU X 0 `U z V / 0 U) w F--, H P LU W I w a UU) JOB NO. 202183 SCALE AS SHOWN SHEET NO. 6