Loading...
HomeMy WebLinkAboutSUB202000173 Plan - Revision Road Plan and Comps. 2020-12-07GENERAL NOTES OWNER: STANLEY MARTIN COMPANIES LLC 11710 PLAZA AMERICA DRIVE, SUITE 1100 RESTON, VA 20190 DEVELOPER: STANLEY MARTIN HOMES 404 PEOPLE PLACE, SUITE 303 CHARLOTTESVILLE, VA 22911 ENGINEER: COLLINS ENGINEERING 200 GARRETT ST, SUITE K CHARLOTTESVILLE, VA 22902 (434)293-3719 TAX MAP NO.: 090000-00-00-03100 (DB 5237, PG.405) 1960 AVON STREET EXTENDED CHARLOTTESVILLE, VA 22902 TOTAL AREA: 5.262 ACRES ZONING: PRD PLANNED RESIDENTIAL DEVELOPMENT (ZMA 2012-0004 & ZMA2014-6) A VARIATION IS BEING REQUESTED WITH THIS INITIAL SITE PLAN AND PRELIMINARY SUBDIVISION PLA T PROPOSED USE: RESIDENTIAL DEVELOPMENT - TOTAL 30 RESIDENTIAL LOTS 28 SINGLE FA MIL Y A TTACHED RESIDENTIAL UNI IS (TH UNI IS) 2 EXISTING SINGLE FAMILY DETACHED RESIDENTIAL UNIT DENSITY.• ALLOWABLE DENSITY PER ZMA APPLICATION PLAN: 6 DU/AC TOTAL ALLOWABLE NUMBER OF LOTS: 30 TOTAL LOTS TOTAL NUMBER OF PROPOSED UNITS: 30 RESIDENTIAL LOTS PROPOSED VARIATIONS: A VARIATION TO THE APPROVED APPLICATION PLAN IS BEING SOUGHT WITH A WAIVER REQUEST THAT SHALL ACCOMPANY THE REVIEW AND APPROVAL OF THIS INITIAL SITE PLAN AND PRELIMINARY SUBDIVISION PLAT. THE WAIVER SHALL INCLUDE A MODIFICATION TO THE LAYOUT FROM THE ORIGINAL APPLICATION PLAN, A MODIFICATION TO THE ROADWAY NETWORK (BUT WILL KEEP THE SAME ROADWAY CONNECTIONS), A MODIFICATION TO THE SETBACKS (BASED ON THE ROADWAY CHANGES), AND A MODIFICATION TO THE TIMING OF THE INSTALLA TION OF THE LANDSCAPING BUFFER AREAS AND SCRIM FENCE. OPEN SPACE.• TOTAL OPEN SPACE PROPOSED = 1.328 AC (25.27.) OPEN SPACE A: 6,850 SF OPEN SPACE B: 50,999 SF TOTAL OPEN SPACE REQUIRED (257) = 1.316 ACRES OPEN SPACE TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION. ALL OPEN SPACE SHALL BE RESERVED IN A DEED FOR THE COMMON USE OF LOT OWNERS IN THE SUBDIVISION AND NO OPEN SPACE IS PROPOSED TO BE DEDICATED PUBLIC SPACE. BUILDING HEIGHTS: MAXIMUM BUILDING HEIGHTS SHALL NOT EXCEED 30 FEET RECREATIONAL AMENITIES: PER PROFFER #8, THE OWNER SHALL PROVIDE AND INSTALL A 40'x5O' FENCED DOG PARK WITH (2) SMALL BENCHES AND (2) ADDITIONAL PLAY STRUCTURES FOR OLDER CHILDREN IN THE EXISTING TOT LOT AREA ON TMP090FO-00-00-OOA1, OWNED BY THE AVON PARK COMMUNITY ASSOCIATION. SETBACKS: FRONT 10' MINIMUM 18' MINIMUM FROM R W OR EDGE OF SIDEWALK TO GARAGE SIDE: NONE - MIN. 10' BUILDING SEPARATION REAR: 10' MINIMUM LOTS 1-4 & 13-28 ( ) 5' MINIMUM (LOTS 5-12) SUBDIVISION STREETS: CURB & GUTTER WATERSHED: RIVANNA RIVER DRAINAGE DISTRICT - NOTE: THIS SITE IS NOT LOCATED WITHIN A PUBLIC WATER SUPPLY RESERVOIR WATERSHED. AGRICULTURAL/ FORESTAL DISTRICT.- NONE TOPO & SURVEY: THE BOUNDARY LINE AND PARCEL INFORMATION WAS PROVIDED BY ROUDABUSH, GALE AND ASSOCIATES MAY 2018. THE TOPOGRAPHY INFORMATION IS BASED ON FIELD SURVEY COLLECTED IN MAY 2010. THE PROPERTY IS CURRENTLY BE SURVEYED FOR UPDATED TOPOGRAPHY FOR THE FINAL SITE PLAN. INFORMATION FIELD VERIFIED BY COLLINS ENGINEERING MARCH 2O20. DA TUM: NAD 83 EXISTING VEGETATION: PARTIALLY WOODED WITH (2) RESIDENCES ON THE PROPERTY AND EXISTING GRAVEL DRI VEWA YS. LIGHTING: NO STREET LIGHTING IS PROPOSED WITH THE DEVELOPMENT. PARKING: PARKING REQUIRED: 2 SPACES PER UNIT + (1 SPACE PER 4 SFA UNITS) 28 SFA UNITS + 2 SFD UNITS = 60 OFF-STREET PARKING SPACES 7 ON-STREET/SURFACE PARKING SPACES TOTAL PARKING SPACES REQUIRED: 67 SPACES PARKING SPACES PROVIDED (MINIMUM (1) DRIVEWAY SPACE + (1) GARAGE SPACE): OFF-STREET PARKING SPACES: (2) SPACES PER LOT = 60 SPACES ON-STREET/SURFACE PARKING SPACES PROVIDED FOR GUEST PARKING = 21 SPACES TOTAL PARKING SPACES PROVIDED: 81 TOTAL PARKING SPACES PHASING: THIS PROPERTY SHALL BE DEVELOPED WITHIN 1 PHASE. BUILDING SITES: PARCELS 1-30 EACH CONTAIN A BUILDING SITE THAT COMPLIES WITH THE REQUIREMENTS OF SECTION 4.2.1 OF THE ALBEMARLE COUNTY ZONING ORDINANCE. BURIAL SITES: NO KNOWN CEMETERIES EXISTS ON THE PROPERTY. STREAM BUFFERS: THERE ARE NO WPO 100' STREAM BUFFERS ON THIS PROPERTY. ANY STREAM BUFFER SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY WATER PROTECTION ORDINANCE. WETLANDS/STREAMS.- THERE ARE NO WETLANDS OR STREAMS LOCATED ON THE PROPERTY. FLOODPLAIN: THE PROPERTY LIES IN AN AREA DESIGNATED AS ZONE X AS SHOWN ON THE FLOOD INSURANCE RATE MAP COMMUNITY PANEL NO: 51003C0407D, DATED FEBRUAR Y 4, 2005. CRITICAL SLOPES: THERE ARE PRESERVED SLOPES ON THE PROPERTY. MANAGED SLOPES ARE SHOWN ON THE PROPERTY BASED ON THE ALBEMARLE COUNTY GIs MAPPING FOR THIS PARCEL. THESE MANAGED SLOPES ARE SHOWN ON SHEET 2 AND SHEET 4 AND SHALL BE MANAGED IN ACCORDANCE WITH THE ALBEMARLE COUNTY ZONING REQUIREMENTS. RETAINING WALLS: NO RETAINING WALLS ARE PROPOSED WITH THE DEVELOPMENT. LANDSCAPING: STREET TREES ARE PROPOSED ALONG THE NEIGHBORHOOD STREETS IN ACCORDANCE WITH ALBEMARLE COUNTY LANDSCAPING REQUIREMENTS WITHIN SECTION 32.7.9 OF THE COUNTY CODE. IN ADDITIONAL, LANDSCAPING BUFFERS SHALL BE PROVIDED ALONG THE BOUNDARY OF THE PROPERTY IN ACCORDANCE WITH THE APPROVED APPLICATION PLAN AND PROFFERS. SEE THIS SHEET AND SHEET 3 FOR ADDITIONAL INFORMATION ON THE REQUIRED AND PROPOSED LANDSCAPING BUFFERS. ALL LANDSCAPING BUFFER AREAS SHALL BE INSTALLED PRIOR TO THE FIRST CERTIFICATE OF OCCUPANCY. TRASH: EACH LOT SHALL HAVE AN INDIVIDUAL TRASH CONTAINER TO BE STORED WITHIN THE GARAGE. STORMWA TER MANAGEMENT- ONE UNDERGROUND DETENTION FACILITY AND A DETENTION POND ARE PROPOSED WITH THE DEVELOPMENT TO ACCOMMODATE THE WATER QUANTITY REQUIREMENT FOR THE PROJECT. WATER QUALITY SHALL ACCOMPLISHED WITH THE PURCHASE OF NUTRIENT CREDI IS. AVON PARK II DEVELOPMENT ROAD PLAN SUB2020000173 SCOTTSVILLE DISTRICT - ALBEMARLE COUNTY, VIRGINIA Lj I IVIr yVr —f —4 N/F JENNIFER L GERARDI F-x xxry43�x— X w� wE, \ f TMP \N/F ALBEMARLE COUNTY I a �* SERVICE AUTHORITY X �BB�55c7I-PG w 272x — x E- w �w is I TMP 90E-9 TMP 90F 8 N/F DENNIS OR N/F IGNACI OR LINDA V OCONNOR TARA L D TMP 90E-7 N/F IAN FARIS DB 4163 PG 261 TMP 90E-6 N/F DANEIL SHUMATE DB 4091 PG 534 DB 4184 PG 210 CARDENA DB PG 77 TMP 90E-Al N/F AVON PARK l COMMUNITY 1 ASSOCIATION INC C/0 REAL PROPERTY INC ------ - - - - -- ---------------- DB 3692 PG 319 ------------- - - - - -- I ' i L T I II IF. I p 5 I I I I I I I +: I I I I ...:::::ee:?g:e ';`•f �e?;r"�; if�''ir Asir;i'it?i'efi;•`i;ler`ii �si' r;`=•'•rr: �i ei:f `Fe' i;lf'� r'?;'?';r�' � �f?ei;�Fe?5�?iii'?'� �`erF�rr�f�ic� � �'? -: LOT LOT LOT - LOT LOT :::::::::::.:::::::":::::::::`:::::::::••::: _ LOT LOT LOT LOT f '' I I I — -— - - 4 2 28 24 I I 26 3 5 2 I I _ 27 3 I _ I O EN SPA C T I I I I I I I � � g I I I AREA B �:��?s=';1;;"Ii;•'._���?','i��'���.i?�s I I I _ I I I I I I I I 50 999 ����;������;�i��:r��•'.�s=�';?"i'? I I I I LOT I :t `-. -- I ` • I --- -- ., :: •.:: •... ..... •... •... ..•...•......... ... ... ... ... ... ... :.. ... ... .. .. .. .. ... •... ,:... '. :aiF=i I ......::::::::::::::::.:::.:::•:::•.::=r: :,e3rfe;:'s;:;:~ ;��;e:: •`s:;; =;r;:?;:;a I � I II ........... ......... ........ LOT 8 ........ ..... .... . I ;; y y`y I I I a. I I LOT 29 Y. 40,020 SF I ?, 0.92 ACRES LOT I I I 9 F" i I I '�1 I w I I I ,I I I -I I I I_ _ �, SJ I I I I I' f I •'•�'�a ^I LOT �- --- -- ----, - -- -- - -- - J I 1 LOT I I SJ -- •: I I I 11 - f LOT �r,._,. LOT LOT I LOT LOT I ,LOT LOT I ' � I � LOT LOT — 22 13 14 15 16 I LOT 17 1 g 1 g 20 21 1 ........................... 12L ------ -------- I ----- '--------J I I I ..7 ffilffiftsvibmw I I I I I TMP 90-30 N/F GARY D BROOKS JR DB 4858 PG 406 GRAPHIC SCA 50 0 25 50 200 ( IN FEET ) 1 inch - 50 ft. IMPERVIOUS AREAS: THE TOTAL OVERALL SITE IMPERVIOUS AREA CAN NOT EXCEED 377., PER THE APPROVED ZMA APPLICATION PLAN: ROADS 0.63 AC (PAVED CIRCULATION PARKING AREA = 27,380 SF) SIDEWALKS: 0.11 AC BUILDINGS/DRI VEWA YS 1.12 AC TOTAL: 1.86 AC (35.39' IMPERVIOUS AREA) PROPOSED USES: L 0 TS` 127,162 SF (2.919 AC) ROADS (R/W & PRIVATE ACCESS ESMT): 44,200 SF (1.015 AC) OPEN SPACE: 57,849 SF (1.328 AC) OFFS/ TE EASEMEN T.• ALL PROPOSED GRADING SHALL BE CONSTRUCTED ON SITE OR WITHIN EXISTING RIGHT-OF-WAY. THERE ARE ALSO EXISTING OFFSITE EASEMENTS FOR THE ROADWAY AND UTILITY CONNECTIONS TO THE AVON PARK DEVELOPMENT. NOTES: 1) THIS PROPERTY DOES NOT LIE WITHIN AN AGRICULTURAL AND/OR FOREST DISTRICT. 2) ONLY (1) DWELLING PER LOT SHALL BE PERMITTED. 3) ALL PROPOSED EASEMENTS SHALL BE DEDICATED TO PUBLIC USE. 4) STREET TREES SHALL BE PROVIDED ALONG ALL THE PUBLIC STREETS 40' O.C. IN ACCORDANCE WITH VDOT AND ALBEMARLE COUNTY STANDARDS. 5) THIS PROPERTY IS NOT LOCATED WITHIN A DAM INUNDATION ZONE. LEGEND TMP 90-30A L- N/F GARY D OR MYRTLE T BROOKS DB 1191 PG 396 EDGE OF PAVEMENT CURB PROPOSED ASPHALT PAVEMENT EXISTING VEGETA TI VE/LANDSCAPE BUFFER GREEN WAY BUFFER PROPOSED EASEMENT Q DROP INLET & STRUCTURE NO. DRAINAGE PIPE BENCH MARK VDOT STANDARD STOP SIGN PROPOSED HANDICAP PARKING SPACE « PROPOSED ASPHALT STRIPING EXISTING CONTOUR 200 PROPOSED CONTOUR 1:1 MILL CREEK g VILLAGE HOMES III VON PART( SITE 4. w ��•x y s TMP 90-32A N/F ROBERT SPAULS DB 982 PG 365 P:E TMP 90-30B N/F JOHN A OR RUBY T BROOKS DB 1191 PG 396 506.71 TC 506.21 EP PROPOSED SPOT ELEVATION TBC DENOTES TOP/BACK OF CURB TAB DENOTES TOP OF BOX 506.71 Tw 506.21 ew PROPOSED SPOT ELEVATION TW DENOTES TOP OF WALL BW DENOTES BOTTOM OF WALL PRESERVED STEEP SLOPES MANAGED STEEP SLOPES PEDESTRIAN AND VEHICLE ACCESS PROPOSED CONCRETE PROPOSED & EXISTING GUARDRAIL PROPOSED FENCE O O O OO 100 YR. FLOODPLAIN VICINITY MAP SCALE: 1" = 2000' a 0 LOT 3 0.83 ACRES I Sheet List Table Sheet Number Sheet Title 1 COVER SHEET EXISTING CONDITIONS LAYOUT PLAN 2 3 4 UTILITY PLAN 5 GRADING AND DRAINAGE PLAN 6 NOTES AND DETAILS 6A NOTES AND DETAILS 7 NOTES AND DETAILS 8 ROAD & WATERLINE PROFILES 9 ROAD PROFILES 10 SANITARY SEWER PROFILES 11 STORM SEWER PROFILES 12 STORM SEWER PROFILES 13 DRAINAGE MAP AND CALCULATIONS 14 DRAINAGE CALCULATIONS 15 SIGHT DISTANCE PROFILES 16 LANDSCAPING PLAN 17 TOTAL NUMBER OF SHEETS 4TR1,SCL 1INS7� L> Lic. No. 035791,E �� 12/3/20 w� &.'SIIONAL U) i Z � Z z O J a LU g O U U CO U) f U)E■■1 i w 0 J a ( W z [) Q H I d o ; w W w U) i ' ' 0 0 0 w N � � M M 0 \ � o d� M M N M i w J -j Zw w J� w O 0 O N z O Q w H r, w w a � JOB NO. 112066 SCALE lit =50' SHEET NO. 1 0� I I I I I I IIII 1 I/ I I II � I I I I I I I � v I I I ✓ �\\\� I, l V A V � \ \ \ \ �� �� I III 1� JI SCOTT R. LLINS�Z Lic. No. 035791 "Ll 12/3/20 ��SSIONAL I I I I I I ✓ / I I J III I I \ \ I I / \ \ \ I I I I I V � V A\ \ \ \ V � I I I � \ 1 1 / I I I � / I ,;/ I III I I I I I I I � \ I �V I I I I I I\ � V �� \�\\✓ \ \ � \ \ V I I I \ \ w o uLf) O z o � o u U m� z I I I 1 I I I I 1 / l I / A / / �■■� � u II II \V I �a A A l l I I I I \ 1 I I / / / I / / / / VA J / / / o-j a o \ \ / Lu w I I I I I I \ I I VI 1 \ v ` \ )` / / �■■� o a I I �\� I I I I I / / / / I / _ z o a I I I I I I A I A `� ` \ IV I I I I I\ 1 1 1 I I I l I l l l �\� A / / > 5 Lu U) w I I I I I I I I /*/\< / w W a / _ � � TMPI 90F�6 I I I I I BUILDING ESC IPTI NS / /l l / I l // / ` / / o I I I I I I I \ I I I\ I SANITARY SEWER \ I NSF DAN I I I I I I I I / l l l / // // / / �� / // Lu EASEMENT \ V I I I I AI. 128 X4� 2 IJTOR VINIY I / / / // / // I v / / w \ � 1 c� �7 y zo' GRADING " ,'.. I i � — DB. 3zgi PG. 607 � � � \ � \ �J 11 4JMA E I I I I I I I� C� C� / / I I / EASEMENT I EXISTIN 8' A I v / I BR K IdUJE N B\JEN�ENT I I I \ DB. 3z91 PG. 607 � — \ \ -PB \4 0 P 5 4 / I l X X X- E/P - E/ I I zo' GRADING I I I I I \ / EASEMENT \ \ 1 \ V v / / /l// / I I I 24 X24 /CONCRETE SLAB ' — — 6 I I I EXISTING z' I DB. 3291 PG. 607 \ V I I I / / / I I I x \ \ X 0 92 I \ \ TMP 90E-7 \ \ Cb NIITY I I / / �u IC. 2� 3� COI�CRET� SLAB/ TMP 90-32A I I I I a I I I 1 NSF IAN FARIS \ V I I I ASSOCIATION IA C�OA I / / / / / I I � M I F/C /C I I / X /, \ \ �SCAR� d w v d I I TMP 90E-9 I TMP 90E-8 \ \ xDB 4163 PG 261 \ / I REAL' P 0} ERTY INC 1 I • I 2 O X 2 u '/ S TO Y V N / / F B� Ejti T� SPA L S I I I I I V `, � w " I ¢' CONNOR LIVING NIF IGNAWO 0 \ I I / / I / TAN x w 0 2LLI I I I I I TRUST I RA L DE I I I I DBI 3 921 PG 3;19/ J I / B6L�'N� ON BA� NTH / / / ID-9 98���i 3�25 I °4 I i PB 5116 PG 289 CARDENAS 71M 1910 A / / / 'y I I I I I ( TMP - 2 y� a 9 a I I I DB 4060 PG 77 I I I I µ I �n I I I/� I NIF ALBEMARLE OUNTY \ I I I I I/IF I AV t Rl m I I I I \ V I SERVICE AUTHOTY x I I I / / I J l I M I I I I I n I I I I I I B 3571 PG 272 I I I / / / / / / / / I I �o I I .t / / 1p0 6 V� I I I 1 X \n ---� I OVEN WIRE N /// // I I I M I I / / �6p co° o ° 4� cQ .r w i / / o 0 �� �� �� ro l0 $� 0 / �/ / / I �y I l0 N �D / l0 (Op O / / / LLJ O� N N \ I I m o '6'6 96 8 x �66 66 e62 6p `b �- ao I l �� �� h �� I / / / / M M 1 I I 1 ) I / a �-1 o \ I `96� F I CD I I .0 N / 1 S58°48'09"E 14.92' 1 F' 1 I �D / / I / / o N IACJ48'077 485.�8' I I I I I 31 ° 2 0„W i / / T— x ✓ x i — IF O1 .. F BE 1 _ _ , \ \ P, � � x � X X--- I \ � \ I I I I I I I I I Zoo' \ N29'06'411 � 9.00, � � < �� x - � X \ X —� X �— I I I I I I I I I I I I I I I � I I I I I I ICI I 1 I I I l / o 1\ I \ I I I I TYP V PROPE,RTY 00LMTSEXISTIi NG FENCEI A \ I II ( I 24 CMPWQ�I�FE�CE ' vH TO BE REMOVED � DB.425 PG.462 1 \ I II I I II I I I I I I I DB.423 PG.572 I I I I I �I I\ 1 1 1 \\ V 1\ / ✓ VA I\ I TMP 90-31, 1\ �� I I ✓ DB.\3561 PG.46 X� A )\ I I (y) 5.262 AC \\\ \ \� I I B. �I \ \ I II I I cY) I I I TO, 229,211 SF \ A \\� I 1 ® � A 10�X2 EXISTING KENNEL EXISTING FEN�E �RA NAGE EASEME T (� B.4 PG.462TO BE REMOVE TO BE REMOVE EXISTING WE L V A \ \ \ TO AlV 1 CONCRETE\ o . G.572 BRICK wA L A V\ V A\ �' \� �. a 1 cY) I I Iw o 1 1 \ X v �To BE vacA I \ \ \ \ \ \ \ \ \ \ I I I I I� o A ) I \ I I I I I I I I \KEG NELI I I I �I �v°° /( / I V A V A \V A V A\ \ V�� ` -- \� �� \\ \ \ \ N 6c'�_�o a\ \ V C) A ry \ I I I I I �)x I I lea 'I I // / \ I I 11 V A \ — x �SPWiALT \ V A \ \ I I \l I I I I I I �cI \ oNc�ET \ FAUCE � v 1 Q N 1968 I I v \ v �XIS� ING� HOME TO REq(,lAlf� \ k �oN CR E�TE v ` 1 \ I I J V \I I I \ A \ \\ I I I 1\ I I I I I III I I I XI \ I \ V \ � — — / / / / / I / I I / /II I I I I I � I II � I I I I I II I I I I II I II I II I II I I I III\ / v\/✓ / / I /1/—i /1 I —I fI- Il I— I 1__I� I =I I -��I \ 1 .�? \ I \ \ 1 I I \ .�l�A � 1 — P / o\/ \ I \� 1 1 1 I I I o� �I\ , sLn RAVE �00 A WU)0, O � � � �O ID O `^O �O0±O.) WOVEN � PATER FIF �N MON X F IN �ON o I 0.orLNE WISE F�NCE OV.I TP PROPEFTYI LIN I � tD O I IF J � I \ \ \ \ I I I \\ \ \ V V A I A A I \ I I I \ I I I \ V\ I V OV V A V J I 66�0'990 _ cb I/ N/ 00I t-0 I �I N o 00I w -4 I I Il I I I I oI JI I 'tIIt / N o 00 /l�0 Cd 00 00 l0 t0 l0 �D t.0 Ln M M M N N rl r16po �0 � kO � kD t.0 (D � ko iD (0 -I y /NLD WOVEN WIRE — F€Tom/o-30BTMP 90-30 \N/F GARYD BROOKS JR ±.�� 4858 PG 406 PERT HN4�OR RUBY1T BROO WIRE FENCE OVER D# 1191 Pa'396 ���✓ ✓b�\�X�o WZ� I I / / / I I� I I � I I / I � / / I I I/ 6✓ � PROPERTY � iNE TMP 6-30A \ � / �N/F GARY D OR )MYRhE 7 BROOKS I --/� / / / / / DB ICI P)3961 ul W U) W Q o o I I I I v EXISTING MANAGED STEEP LOPES zz GF�APHIC� SCA E \ \ - — — — — ; / / / / / / / / / , /40 / 20 40 8 / 160/ / IN ET //1 inch 740 �t/ z Q I..L v I o z Q O O 0 z 1 0 v � z Q u) X z W O Q w w a � JOB NO. 112066 SCALE ill _40 SHEET NO. 2 LOT AREA TABULATION LOT NUMBER LOTAREA (SF) BUILDABLE AREA (SF) 1 2448 1405 2 1151 911 3 1152 912 4 2169 1427 5 2007 1303 6 1566 1237 7 1568 1237 8 2050 1338 9 1971 1273 10 1541 1211 11 1535 1205 12 1994 1292 13 2509 1713 14 1226 986 15 1226 986 16 2414 1659 17 2301 1567 18 1681 1351 19 1681 1351 20 1222 982 21 1679 1350 22 2297 1560 23 2141 1408 24 1549 1219 25 1130 889 26 1559 1225 27 1559 1229 28 2134 1427 NOTE: 1. ALL WATERLINES, SEWER LINES, AND FIRE LINES FROM THE MAIN TO THE STRUCTURE MUST HAVE A VISUAL INSPECTION PERFORMED BY THE BUILDING DEPARTMENT. 2. WHERE THE FLOOD LEVEL RIIMS OF PLUMBING FIXTURES ARE BELOW THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER, THE FIXTURE SHALL BE PROTECTED BY A BACI<WATER VALVE INSTALLED IN THE BUILDING DRAIN, BRANCH OF THE BUILDING DRAIN, OR HORIZONTAL BRANCH SERVING SUCH FIXTURES. PLUMBING FIXTURES HAVING FLOOD LEVEL RIMS ABOVE THE ELEVATION OF THE MANHOLE COVER OF THE NEXT UPSTREAM MANHOLE IN THE PUBLIC SEWER SHALL NOT DISCHARGE THROUGH A BACI<WATER VALVE. NOTE: ALL LANDSCAPING EASEMENTS, BUFFERS, AND SCR ENING SHALL BE PLANTED IN ACCORDANCE WITH THE APPROV D PROFFERS LANDSCAPING SHALL BE INSTALLED PRIOR TO THE FIRS CE IFICAT OF OCCUPANCY FOR ANY PROPOSED UNITS WIT IN T E DEVELOPMENT AS DETAILED IN PROFFER �. PROPOSED 2o' DRAINAGE AND LANDSCAPING EASEMENT (LANDSCAPED BUFFER AREA) DB.__PG. AREA OF PROPOSED ONSITE LANDSCAPE BUFFER w� CO NOTE. SCRIM FENCING TO BE INSTALLED IMMEDIATELY FOLLOWING GRADING IN THE LOCATION WHERE THE SCRIM FENCE IS TO BE PROPOSED zo' LANDSCAPING EASEMENT- NATURAL LANDSCAPED AREA OR REPLANTING/NEW LOCATED. LANDSCAPED BUFFER FOR ANY DISTURBED AREAS /T = DB. PG. r m :200 j I I zo' GRADING NOTE: IF TREES RE LOCATED WITHIN 5' OR LESS OF THE PROPERTY EASEMENT I EXISTING 8' EASEMENT DB. 3291 PG. 607 E P - E DB. 3z9i PG. 607 LINES ADJACEN TO TI/IPgoF-A2, TIVIPgoF�42, TMPg�=F=43;aR I � /I TMPgoF-F-44, T E DEV)=LOPER SHALL REMOVE THE TREES ON THE XI5TING 32' ADJACENT PRO ERTIES THE REMOVAL OF 5 WILL BE TMP 90E-7 SUBJECT TO TH EXISTING PROPERTY OW ER'S WRI N APPROVAL. `' I F/C - F/C TMP 90E-9 o er � d o TMP 90E-8 N/F IAN FARIS ACSA PROPOSED 1 r� y I o 00 I 0' CONNOR LIVING DB 4163 PG 261 �� o w 00 N NFIGNACIO 0 WATER SCRIM FENCE o ,� ri h N „ I TRUST LANDSCAPING WITHIN i ' r~ n SC G 5 FENCE � o d C �' DB 5116 PG 289 TARA L DE LANDSCAPE BUFFER THAT TANK ry d w �, I u U I CARDENAS ALONG Z ABUTS ACSA WATER TANK TMP F-A2 PROPERTY q �h I DB 4060 PG 77 PROPERTY SHALL HAVE \ H- v1 NIF ALBEMARLE COUNTY LINE 2 o vi I PROPOSED io' PROPOSED SCRIM FENCE SIMILAR LANDSCAPING TO SERVICE AUTHORITY q I LANDSCAPING FENCE ALONG PROPERTY LINE WHAT WAS PLANTED WITH DB 3571 PG 272 a I� I 2 ADJACENT TO TMP of -A zo' GRADING I i CONC ETE D .. MILLING AND OVERLAY FOR IMPROVED — — — ASPHALT DRIVEWAY "PROPOSED 20' S 24" CMP IMPROVED ASPHALT EMERGENCYACCESS \ DRIVEWAY EASEMENT �� ACCESS FOR (2) LOTS DB. PG. CONCRETE LOT 30 d 37,445SF--- o.86 ACRES ASPHALT - O 00 THP 90-30R N11F JOHN A OR RUBY T BROOKS DB 11191 PO 396 0 PLANTED THE LATEST AVON PARK PROPOSED i5' LANDSCAPING - � N rz m 0 I EASEMENT 9 i F-M PG. PROPOSED 5' STORAGE TANK SECURITY EASEMENT (LANDSCAPED PR0POS_E_ j 10, \ I �n I PROPOSED zo' DRAINAGE AND LANDSCAPING COMMUNITY FENCE IMPROVEMENTS PLAN BUFFER AREA) LANDSCAPE I LANDSCAPING EASEMENT EASEMENT ASSOCIATION INC CIO PROPOSI PROPOSED DB. PG. EASEMENT I � (LANDSCAPED BUFFER AREA) DB.--PG. REAL PROPERTY INC I - �1 LANDSC) CG-z CURB S58`4� 09"E 114.92 DB.____PG. °L _ DB. PG. I DB 3692 PG 319 n LANDSCi S58° 8'07' E 485.78 S31 °02'03"W 3.10' -r y DB. F o' FRONT - — S59°2 1'51 "E 370.96' r S ETBA I• 2 O I/Jj/ k 1 O ; �, PR P ED - B PROPOSED O OS CG 2 CUR I I'•1'•l.-' ' OO 200 -- - PARKIN NO G N PARKIN G-6 C RB O G C U •PROPOSED EMERGENCY ACCESS •2 I SIGNTYP. ( ) .1 SIGN TYP. /�` R AD REMOVABLE B LLARD O O 5 AI 5 R EARS ETB C ` I f 00 � ° N — LL �F R o EA ET 5 BA K — — 8 . f. 1 so R AR SET ACK PROPOSED CG — — PR D 9 LOT O I 5 4 I I — 2 DRIVEWAY I ENTRANCE I ROPOSED 20 LANDSCAPING — — - EASEMENT NATURAL LANDSCAPED:':.-:: - P P E P q 0 �w w 0 CO -0 w�co owl o� � O PROPOSED PRIVAT ACCESS EASEMEN DB._—PG. TR - - AVE WAY PARKIN ; ; ;; V G � '••- ��:' AREA OR REPLANTIN EW ::rr::: 1 LOT LOT LOT LOT :.,•;..::..::..::.:::. r — — _ _ LOT 2 LOT LANDSCAPED BUFFER FOR ANY N � 3 -.L T LOT ..... .. •.. •., ... •.. •.. •.. •.. •. .. .. .. .. .. .. .. •.. •.. •.. o LOTI O LOT I .. .. •.. •. .. .. .. .. .. .................. ...... •.. •.. •:•::;.:: - rn 2 2 2 w f 8 4 4 2 . N 2 _ .. •.. •. .. .. .. ., ... •.. •.. •.. •.. •..•• . ..,,....••..••..••..• DISTURBED AREAS — LOTT N 1 \ a I 0 � o N 0 I I v I � - _ h � � _ � ... � -. •• .................- .. ... .. .. .. .....:::� � TMP 90 iz xi8 ASPHALT _ W o •.. -.. .. •.. •..... io FRONT SETBACK \ o : • . :: •:: •:: •: •: f N P o O PARKIN k •• ~ " "• •• ""' DRIVEWAY MIN. OPEN SPACE (MIN.) k I I I o .'2 9.2 11 �I L SIGN TYP.) BPR OSED AREA /•. / W I / 7 r, W _ STOP SIGN TYP. S _ q CG 12 TYP. o h o 1 F o — 5 55 S 1 I / �I 1 I 1 1 1 P 1 1 — — - - 1 1-daEXISTING RAVEL - 1 S GG O O i 3 2 2 `� 0 1 22 0 16 16 3 4 22 - 3 f� I I I s- PROPOSED ED DRIVEWAY T BE N I I CONCRE T L � CG-iz TYP. �IMPROVED T AN ly k I `I ASPHALT DRIVEWAY+8 PR POSED� \ GUARDRAIL I TO SERVE LOTS z9 I — — — — 5' CONRETE W � •••�LOT 30 — — a VD T STD. I v � u O S � 2 AND 3o I ' SIDE SETBACK 1' SIDEWALK DESOTO DRIVE w c� DESOTO DRIVE PROPOSED I "'"'"''' LOT 9 445 I 5 -- (TYP.) °N aTN w N a_ N w CG-6 CURB - GR z I 0 020 SF I 8 49' PRIVATE R W �` �, � 49' PRIVATE R W w � I NOTE: SLOPE OF 4 � I I o.86 ACRES — — I EMERGENCYACCESS 0.92 ACRES I o I 00 + MAILBOX , F 2 0. r .. i ,. 1 y :i : I I ROAD SHALL NOT I I LOT N KIOSK �� I: , s l + I r k .%fj t� + I k r �+ `fifj I I EXCEED 16 /o I I ti 'Z o PR I C� OPOSED I I 1 I � CONCRETE PROPOSED zo' 0 1 0l � 1 '1 1` 1 - -� I CG 2 CURB - ] 32 16 1 2 � p 22 22 i6 ' 22 3'O I I EMERGENCYACCESS PARK 3 12 NO ING A. N r R N I O 5 TBA K zo RON SET ACK I EASEMENT I N — MIN. I / LOT VS IGN TYP. 1 DB._PG._ G. I 1968 a / I I I E V 1 0 Q 1 1 � I I I I— — zo' 18' / / Q / CONC ETE T I ]O STREET SIGN (TYP.) ,- m k PROPOSED sz' TR V LWAY PARKING \ w o \ I ASPHALT EMERGENCY N - - �p �p O _ ACCESS ROAD I LOT w 4 I I _ I n 11 � I� / 1 i 70 o LOT LOTI LOT LOT ran + ': LOT LOT LOT OT REAR SETBACK — 1 14 i5 16 �- LOT :� 20 LOT — — — ----- --- -- — 3 p cn 1] 18 19 21 22 \ --- I O R --_-_ I GRAVEL + PROPOSED 47' PRIVATE N z4 z8' — — J � - gyp — — — — — + ..ACCESS EASEMENT LOT I I I I I _ _--_—_ - TRAVE WAY PARKING I :DB. PG. — — — 12 _ — I + — — — L — — — — — — — — fREAR [ETBAC zo REAR ETBAC— L — ]OI - PROPOSED CG-6 CURB : - — _-- + k —r; NO PARKIN G �r' OPEN SPACE SIGN (TYP.) N59°18'07"W 1,072.99'(T) STREET TREE NO PARKING - _ AREA A: SF SIGN (TYP.) PROPOSED io' LANDSCAPING (TYP.) 7�334 �--------------------------- EASEMENT (LANDSCAPED ------------- ::1 = DB.--PG. --- — TMP 90-30 N/F GARY D BROOKS JR DB 4858 PG 406 PROPOSED io' LANDSCAPING PROPOSED DOUBLE -SIDED EASEMENT (LANDSCAPED VERTICAL FENCING (BOARD BUFFER AREA) ON BOARD) PRIVACY FENCE DB. G. i NOTE: ALL STREETS WITHIN THE DEVELOPMENT SHALL BE MARKED WITH NO PARKING SIGNS ON BOTH SIDES OF THE ROADWAY. PROPOSED 3 BOARD FARM FENCE ALONG PROPERTY LINE NOTE: (*) DENOTES THE LOCATI N OF THE AFFORDABLE UNIT WITHIN THE DEVELOPMENT. PER PROFFER #1, THERE SHALL BE (6) AFFORDABLE HOUSING UNITS WITHIN THE DEVELOPMENT. TMP 90-30A N/F GARY D OR MYRTLE T BROOKS DB 1191 PG 396 30 0 10 GRAPHIC SCALE 30 60 ( IN FEET ) 1 inch - 30 ft. THP 90-30R N11F JOIN'/ A OR RUBY T BROOKS RR 1191 PO 396 120 .In op NIP', SCOTT R. LLINS77' Lic. No. 035791 1�0Als��IOIVAL 12/3/20 ' 1SA � V1 ~ z Zz o Q w � 0 F r 0 1■�1 u w coa � Q J w z o Q � a z Lu LV w Lu 0 0 0 Lu r1`1 I- rn f ) o Vol w W KA J j 0 rn C`7 Cn N C`7 N O Cn N N Q Lu J_ U) Lu O J Q U Lu Lu Lu CO 1 Lu O (N z O Q I— w r u1 w cr_ _ a JOB NO. 112066 SCALE 111 _ 301 SHEET NO. 3 6 z w w z z w z J J 0 U 0 E 0 U c N L V) W Q O a, a O U L O U L O _0 0 U L c O U O 0 c U c L O a M 0 Q L Q T a O 0 E 0 u) a a Q L O 0 a _0 U O L Q 0 a E �o a z w w z z w U) z J J 0 C� 0 Q 0 Q _D U X 0 E 6 U O _0 _o U 0 a u) O U V) C) Q 0 Q) NOTE: INDIVIDUAL PRIVATE DOMESTIC WATER BOOSTER PUMPS SHALL BE PROVIDED IN EACH HOME TO MEET THE MINIMUM WATER PRESSURE REQUIREMENTS. REMOVE EXISTING 12" B.O.V. AND TIE-IN TO EXISTING /.> 12" DI WATERLINE 3 I °0 ' I Lj O I SANITARY SEWER EASEMENT X X x I DB. 329- PG. 607 X x �t - I ACSA -CON CO I I TMP 90E-9 WATER ry w , I O' CONNOR LIVING TMP 90F 8 � o w I N/F IGNACIO 0 TANK TRUST x o I i DB 5116 PG 289 TARA L DE CARDENAS TMP F-A2 r= q rl g I DB 406O PG 77 N/F ALBEMARLE COUNTY SERVICE °j I� PROPOSED 20' SANITARY SEWER - AUTHORITY X - DB 3571 xG 272 d � � � � AVONPK-1-1 3 EASEMENT i � PROPOSED TYPE A r BLOW OFF ASSEMBLY I LOCATION OF SANITARY S58°48'09"E 114A2' TIE-IN CONNECTION S� `aR'n7"E 4R� 7R' 0 o T T C. I I I EVA 24" ;TT r� Epp (#!CR. LLINS� Lic. No. 035791 12/3/20 o�,�ssI�NAL E1SG��� z Zz o Q w � 0 r 0 1■�1 � w m � a Q J w z oLu Q a Ln LV w Lu 0 0 0 Lu r14 [--- rn f ) \ o —4 -1 —1 TMP 90E-7 N/F IAN FARIS DB 4163 PG 261 - H1),0v01a11v1v 11vu u/ v NOTE: ALL TH UNITS SHALL HAVE ROOF REAL PROPERTY INC DB 3692 PG 319 DRAIN SYSTEMS THAT WILL COLLECT THE RUN-OFF AND CHANNEL IT FROM THE ROOFS ROPOSED 8 SANITARY SEWER (TYP.) PF TO THE PROPOSED DRAINAGE SYSTEM. -4 S59°21'51"E 370.96' r ;•.. •.. - PROPOSED 20' I i.. fn PROPOSED 6 DI WATERLINE TYP. ----- WATERLINE I ;;r::•.: ••.:.•.;..,. EASEMENT EASEMENT .:� • v, m m 'I I ■ e e i■■ � o w w E c n■■■■■■■ ■ ■ n■■■ w p, e: ■ 0 fr e L f►! i i w ti F! L i! 7� w w e L f!! i i f 7 G w !1 E i f! w M f f i y w M F•■�� ®��•� PROPOSED�- I SERVICE LATERAL (TYP.) ,I Y I Y. ■ I • __IP.■G O I � u n, • - —. •�o�� ®® .i�1'cu® _L�► —�_.— _mil M o�e ......... . .... / • /� \ :TMP 9 D 31 , Vm 5.262 AC /N \ 229,211 SF I OPEN PA S CE' •r ° CONCRET FLOT - / I. I L :.I. I. sly' I � I.I 1' 'i .I -1 R" -.1 —''r '.� � co I � — w :- PTROPOSED 6"X6" TEE I - l q _ a I ,. LOT 30 AIO - 2 6 G.V.- 0 1 + 0 0 2+00 DSO 0 D IV + 13 315 ;:...: •.. ••.: •.. •. •.: 1 •••- LOT w w w w w w w w 9 o � �'0 Iw1 e I I 37�445 a, _ _ I 4 A I I 40,02o SF o.86 ACRES o 9 RIVATE W � � � I I o. 2 ACRES M 9 � � 1 � 1 w� I I I o - CD I LOT I W q O I, I r� o I 1 z 9 _J d - I I I - - I i CONCRETE o - I o I l I I I f 0 I I I A. FMJCE" o I _ I � I I I I LOT I I O 1 - ' I I I I 1 .I I 968 � I I I .. . 1 0 1 I I r — I . I I I I I I I -I, PROPOSED zo' C O V C E TE TRAFFIC RATED I I I .If go* PROPOSED WATER II I PROPOSED 6 o BEND PROPOSED 8 SA ITARY SEWER (TYP.) I 9, PUBLIC UTILITY / METER BOXES � 1 SERVICE LATERAL (TYP.) I I II �' 1 11 II I EASEMENT LOT I I �» I I - 1 I LL --- I I LJ I I I a 11 I I •.. I I I . _ I I I I 1 i MH 5 LOT LO LOT 11 LOT L LOT 11 LOT jjj I I I - ----- --- ------------ A, ! 1 16 LOT LOT 11 LOT LOT 1 1 I • ...•...; JAI � � _ �-� �O S I 13 15 ---I 1 1 1 1 18 1 2O 21 22 1 I I I I 1:1 00 * 7 1 9II *------ 1 I d L- PROPOSEDTYPEA ::::�---- _— - GRAVEL LOT I - JI I BLOW OFF ASSEMBLY-:.-..':: -- -------- - ----------------� I I I I 1 i 2 I I IN Lm ----I--I- - - - I- -- IF IN MON I L - - O OPEN SPACE PR P ED 12 X •R. PROPOSED TYPE A BLOW OFF ASSEMBLY PROPOSED VARYING WIDTH PUBLIC UTILITY EASEMENT TMP 90-30 N/F GARY D BROOKS JR DB 4858 PG 406 PROPOSED 12" DI J WATERLINE EXTENSION WITHIN THE PUBLIC R/W TO THE PROPERTY LIME -- NOTE: ALL PUBLIC WATER AND SEWER FACILITIES SHALL BE DEDICATED TO THE ALBERMARLE COUNTY SERVICE AUTHORITY G.V. (2) 6" G.V. I PROPOSED TYPE A BLOW OFF ASSEMBLY I @ 0.28' I I •I. I � � -- TF I N59°18'07"W 1,072.99'(T) --------- — ------____-- PROPOSED 25' WATERLINE EASEMENT NOTE: ALL PUBLIC WATERLINE EASEMENTS SHALL BE PLATTED PRIOR TO FINAL SITE PLAN APPROVAL PROPOSED 20' PUBLIC UTILITY EASEMENT TMP 90-30A N/F GARY D OR MYRTLE T BROOKS DB 1191 PG 396 30 0 10 GRAPHIC SCALE 30 60 ( IN FEET ) 1 inch = 30 ft. THP 00-30R N11F JOI11iN A OR RUBY T BROOKS RR 1191 PO 396 120 1W W V I C'7 CIO Cn N t' J i N O Cn N N Q Lu J_ > U) Lu 1 O J Q 2 U Lu U) Lu I..L C0 Lu C:) O (N z Q J J_ F- D I- W r u1 w cr_ _ a � JOB NO. 112066 SCALE 111 _ 30 1 SHEET NO. 4 C� z W W z 0 z W z J J 0 0 0 0 E 0 U c N N N Q N 0 a s= 0 U L (n f- 0 U L 0 a �o 0 U L In S_ 0 U 0 N 0 U L 0 a U) O Q L Q T 0 O In a a Q 0 _N O �o 0 U 0 Q Q O a E _o a z W W z z W U) z J J 0 0 0 Q 0 L Q U x E 6 U 0 _o _a U 0 a In O 0 In C) 0- 0 Q) I �\TIC[ \ I I 1 1 I 'In,, �� \ / / / / / ASCOTT R. LLINsZ' VARIABLE WIDTH / SWIM FACILITY- , / / / \ / Lic. No. 035791 n ACCESS EASEMENT 12�3�20 DB.__PG. / 0 S \ I I I I sIONAL - I 2 ;;;\ \':;:.:" e \ 1 PROPOSED RIPRAP / I v / I I I I I I m \ I I I \ \ I I I I •"•' •••••• �_m _ _ ♦ �OUTFACE INTO I I I / I I I I I I I I I I I \ ..;:- �T"• •••'•..'••..�..•'. •..'••..' _ ROADSIDE DITCH I I I ----- -------- I I II I / � � I III I I I I I I I I I I •; ::,.::::;�: __ y_- I - � - - ` -`` �- �- 24" I I �r - I ��-------� 'MP ,go (YO \� I I I I \ \ \ A 23\ 4 N \;- \ \ � � • rn: � � \ IMPhOVED ASPHALT z 00Lu 'DRIVEWAY ACCESSFOR 2 LOTS 1 0SWM 2 \ \ -0 \\\ \ V) o z o V I I I I ) \ 1 \ Ln w o a� z o 0 LOT 30 u a m U.)z z 1 I I �r,�f5 - A 1■■1 o.86 ACRES ( - /" \ \ \ \ \ o � o X \ \ \ o oc �i vim_ \1 \� V �\ \ \ 0 F o a u')w W w I I I I \ I00 C ime w a I o I I I I \ w l0 I \ 1 \ \ \ \ \ I I o W I a I ao I V A \ \ \ V \ \ \ l I II 1O 00 00 I I \ \ I ( \ \ \ \ I I r \ I \ 00 00 \) I I \ IIII 3 \ I \ \ \ \ I ► L, `^ 1\ LID a)I I I \ I I I 20' GRADING co � j - - 2o' GRADING EASEMENT- V-__--EASEMENT \ I I I X x \ DB. 3291 PG.607 I \ \ I DB. 3291 PG.607 \ \ \ �( \ \ % ) I \ Lu r M M I \ -4 rj x\ X 9z I I \ \ TMP 90E-7 \ c, 6 I I I \ X \ I ( I / �, �I I I TMP 90F9 TMP 90E-8 \ NIF IAN FARIS \ 0. w I O'CONNOR LIVING I 1 N F IGNACIO 0 ,DB 4163 PG 261 �. �� o w I l \ \ o oo I I I I TRUST \ / / °j w `" o I� I I I \ \ � X TARA L DE-- - / I I DB 5116 PG 289 I /l J�cCARDENASAMP F=A2 E,rz ri I DB 4060 PG 77 ERVICE AUTHORITY X o \00 I I PROPOSED 8" HDPE ROOF DRAIN SYSTEM I I NSF ALBEMARLE OUNTY � � -I \ I I I \_?�B 13571 PG 272 .I W/ io PRIVATE DRAINAGE EASEMENT (�x --- -J PROPOSED 8 HDPE ROOF \ DB. PG. i �o I NOTE: ALL TH UNITS SHALL HAVE ROOF \ 6°6 N REA PROPERTY NCCIO DRAIN SYSTEM W/ io'PRIVATE 9 i � / �\ \ `6) �1 ('0 ,6'I° 68 66 / \ j I DRAIN SYSTEMS THAT WILL COLLECT THE \ \ / `O oo �� 1 G DRAINAGE EASEMENT 6 6 6� 6 6 j36\ PG 3119 I 1O ` V / VARIABLE WIDTH I �� h 0 I I \ o G �g , ro �c2 ry oo I I RUN-OFF AND CHANNEL IT FROM THE ROOFS \ \ \ m rn m .9 6 DB. PG. 6 \ to N \ 0 h op,I 68 / 8z / / / I 1° I I I P� TO THE PROPOSED DRAINAGE SYSTEM. �� SWIM FACILITY \ S58°48'09"E 1 4.92' \ 7 �/ �\ I I 1 / \ i C`7 S�8°48'07' E 485.78'I 16 i ACCESS EASEMENT / 5 21 51 E 0.96 • I 62 682 m / 1 N w�r 9 I N 3- 3 6 i- o -J'. 0 00 I 8 B Ir I 3 D•• j rn 4 I 3 A C o - m '� r N I _ 7 w N I 00 a: I • LOT so I •;,.:::•�:..:::.::. Oo ' I ' 1 I I r •.. •.. • . .. •. • . .. •. - 9 5 L-\_ I \\\ �� - - i 8% 687 I ■�■■■ 9 7 I g 1 I I tt ••' " .• \ 1 t: : •'rI i �-- -I LOT 4 I „� „ ... �.................... ,� o i LOT 1 L T 2 I o I - - - � LOT O LOT C� LOT L T s , � � .. .. .. .. .. •. .. ... . , .... .. .. �. .. .. 6, ; , \� 1 I LOT � I I 6. . , ... •. •.. •.. •.. • . .. •. , .. . , .. •. ,. , ... i -- -- ��-y 3 LOT ------ �'c 2 ' I GAR-6 8 to s .. �o } .: •.:; •.:; •.:; ::: _ _ W AR- - - - 7 _ l.. •. .9 - I I G 6 _ I � _ _ � _ GAR 680.00 •. .. • ' .. • o � GAR 684.i7 _ GAR 626.67 ... ••.. � •. •.. m ... .... ... ... . . .. ... . . ... ... .. �-- - L T AR- - { O GAR 6 6.i G 6 _ o •• .•• .••.. •..••. �. ,•..,•..,•. ,•..,• .,•......:...:........ .. I I _ rFFE-6 h _ - 7 _ N 1.. •..`•. ::: 3 _ _ I _ GAR 680.6 ..••. •. •.. .. •. ,....••..••.j •..••..••.. ..•• .••..'•..••. •.. - } GAR 6 i r I 7 FFE 68 .8 I 7 FFE-680.6 _ FFE-6 `; •.. :: - _ 4/o FFE-68 .8 FFE 6 00 1 - / J - FFE-681. �0 1.. •: o C•.: •:: :: ::::. �, FFE-68 33 1 GAR=6 \ N - / - \ N 9• 77�33 �, 1 11 GAR- 8 .83 I 1 11 � s '•k�::�: ::�� TMP 90 31 � 2 A -F I 11 1 I I I 1 1 � � �' s� � - ::�:•• \^..� 7 00; 3 � \ FFE=6 8.00 \� �o / - I FFE=6 0 � I 11 I 7 II I � � � � F. ..•2o'•PUBLIC 5 5 6 i� 6 5.262 AC 6 :': c•': \ I 1 ::.-.. PROPOSED STORM o r •:: •:: '`DRAINAGE ESMT \ \ / / Cn \ oo I I i I �" I � y LOT - - :� 229 211 Si �- o o I / 0 6 U ••fir:••:: DB. P W I I o o 'o OUTFALL PIPE G. I I / / 2 � I SWM z I _ o � 4 L 0 0 o 7 o I AR- 4 i 688. o - \ I - M 0 5 ei- - u� \ M \ � I - 6 -- I 6 4 / 1 II I I I I � I O C _ PENSPACE FE 68 .i O 1 / 9 7 I'j i 5 \ - \ \ 5 \ I I I 5 60 s 4 I O I I \ \ I ao 1 I � 1 i i• CONCRET J w 22 , 1 I• 1 8 I I RI K � LOT W \ °2o PRIVATE I I AR-68.8 i�� :� v .� / o b co • I / I 7 3 0 1 I A - \ 6o6 \ \ 1 I• I - -!1 � FE-688. o \ / I I 1 5 I. DRAINAGE ESMT \ \ \ z. •- I Q q I O _ / I I I I / \ / \ LOT 3 I_ � Ip' I VARIABLE ---- JI \ \ �, �' w \\ �\0 W �, ( \ \ \ LOT 29 / / I \ \ \ \ \ _ to II - I k- IVE a 1 DES DR E I WIDTH SWM co \ 1 / 6o8 \ 3�i+4 U a, Lo ; o - I : - _ _ - _ - - J I I -FACILITY � �o�, \ \ \ I ' 40,020 SF 0.86 ACRES � h- I----------�� 4JR TE� R W 49 PRI�ATE I 1 \ l l 1 �1\ � I I � o � I ACCESS o,.g2 ACRES / I � �� II I R� - I \ I EASEMENT I o LOT \ o _ I q 4 I - - b g t DB. PG. W AR= i o I \ 68 i o v� I � 7 7 z I I 9 / 9 / I 4 a 1 PRIVATE - 1 o' I - I - CONCRETE FE I 688 8 � I 3 6 2 t~ I i � \ . I o o I I \ � � � cY � I I \ DRAINAGE 0 0- 6 7 6 I� \EASEMENT rz ono I I \ 10 �:I 1 6Z \ \ U) LOT �o / A \ \ R=687.i7 0 -I o / \ #1 965 4 � � _ 10 � I � I _ I � _ I - I FE 688.8 - - 1 j 3 I GAR=685 00 AR- IC~ - o CL4 9 J l / 20 I _ _ 6� \ O N C \\TE \ W I G -683 50 W IGAR=6 o.17 I GAR 7 .83 GAR=676 .i / / 6 \ \ \ \ -7 FFE=68 6 W I \ / I- _ 7 - 1O 5 _ q FFE 68 .i 8 I - \" W I PROPOSED 8 I I 12 GAR=6 6 4 7 / 1FFE=68 .83 FFE-6 9 0 FFE=6 6.8 q _ - - - - A 5 I � 5. 7 GAR=68 � I I" 7 3 � \ > HDPE ROOF DRAIN I I 1 I IFFE=6 - 4.33 PAR 68i.5o11 GAR=679.5o 1 GAR 7.50 1 _ - I 61� \ \ \ \ LL LOT -, 33 FFE=685. o / - _ _ _ ( \ I \ L.L \9 FFE 68z.i FFE 6 8.i 00 - I = 7 7 _ � FFE 680.i 1 � _ SYSTEM W/ zo I 11 AR-687.i7 3 /o I I I _I 7 v - - - - - - I I \ FE=688.83 �- - i9 I LOT LOT LOT LOT - _ - - - - N ��' o \ \ \ \ \ Cn 'PRIVATE ---- 11 LOT 1 LOT 1 LOT - i 1 LOT 1Lf 1 16 LOT LOT 20 22 - DRAINAGE 5 1 18 21 h _ _ ---'- --- \ n, _ EASEMENT I \- 3--\I �c * ---��I 1 1 19 1I �c -I I 7 - - - \�o o _ cps �,- - _- - RAVEV O� I \ DB. PG.R=-68.8 II \ --� --- -- - _=I = �-- --�- --- -- -- 1---- - 1 1 I ` 0 0 -50Vo o LOT o W 0IF @ 0.28E688 1 I \ I \ I -J - - --- - - I' 686 - __8 --fizz- -{,g- �.---- --- - - -- - --- --- - - - �- -- ----/--------I--- ---- -- -- TP I I Q O -I 688 fn 9 I PROPOSED 8" �� i � � I oHDPE ROOF DRAIN o � � CNI o /ioo rvo 00 o oLn ry) o �00 .o� o 4o 00 o n, �oo �\ PRIVATE kD O� 10 (o b �oko 20DRAINAGE DRAINAGE O i - -- - � HDPE ROOF DRAIN I I ESMT I � I \ EASEMENT 20' PUBLIC / I I I I SYSTEM W/io' DB. PG. DB. PG. DRAINAGE ESMT / / I I I � TMP 90-30 � DB. PG. / / / PRIVATE �zo' PUBLIC UTILITY I I I I \ I \ \ � / I I \ \N/F GARY D BROOKS JR / DRAINAGE ESMTTMP 90-30B I Ix EASEMENT I I I I I - 11FI TOHN A OR RUBY T BROOKS I I Z\B 4858 PG 406 DB. PG. / DB. PG. I I \ __j / / / / N I � / i I I I I I I I I � � / �� n��� �� ��� I XISTING MANAGED STEEP SLOPES TO REMAIN ) TMP 90 3bA I I I NOTE: ALL PUBLIC WATERLINE \N/F GARY D OR )MYRhE BROOKS I GRAPAIC /SCA�E \ NOTE: ALL PUBLIC WATER AND SEWER / DB 11 1 PG 396� I I I / I I I / EASEMENTS SHALL BE PLATTED PRIOR / /9 � � I I I I � I I I 30 � o / 0 30 / so / 120 FACILITIES SHALL BE DEDICATED TO / / TO FINAL SITE PLAN APPROVAL \ / / / \ I I I I I I I I / I I -THE ALBERMARLE COUNTY SERVICE / / J / I / I I \ AUTHORITY / - IN �1;'1;'T ) � I / I I inch / 30 /ft. I- Lu Lu _ a � JOB NO. 112066 SCALE ill _ 301 SHEET NO. 5 6 z w w z 0 z w z J J 0 O 0 E 0 U c V) Q O a, a 0 L (n O U 0 �o 0 U L cf. c O U O 0 U c L O a U) 0 Q L Q T a 0 u) 0 E C) u) a 0 a L 0 0 �o U 7 0 Q 0 a E �o a CD z w w z z w U) z J J 0 0 yT. Q 0 a U X U U O -o U 0 a U) c 0 V) C) o_ Q) V) GENERAL CONSTRUCTION NOTES FOR STREETS 1. CONSTRUCTION INSPECTION OF ALL PROPOSED ROADS WITHIN THE DEVELOPMENT WILL BE MADE BY THE COUNTY. THE CONTRACTOR MUST NOTIFY THE DEPARTMENT OF COMMUNITY DEVELOPMENT (296-5832) 48 HOURS IN ADVANCE OF THE START OF CONSTRUCTION. 2. UPON COMPLETION OF FINE GRADING AND PREPARATION OF THE ROADBED SUBGRADE, THE CONTRACTOR SHALL HAVE CBR TESTS PERFORMED ON THE SUBGRADE SOIL. THREE (3) COPIES OF THE TEST RESULTS SHALL BE SUBMITTED TO THE COUNTY. IF A SUBGRADE SOIL CBR OF 10 OR GREATER IS NOT OBTAINABLE, A REVISED PAVEMENT DESIGN SHALL BE MADE BY THE DESIGN ENGINEER AND SUBMITTED WITH THE TEST RESULTS FOR APPROVAL. 3. SURFACE DRAINAGE AND PIPE DISCHARGE MUST BE RETAINED WITHIN THE PUBLIC RIGHT-OF-WAY OR WITHIN EASEMENTS PRIOR TO ACCEPTANCE BY THE COUNTY. ALL DRAINAGE OUTFALL EASEMENTS ARE TO BE EXTENDED TO A BOUNDARY LINE OR A NATURAL WATERCOURSE. 4. GUARDRAIL LOCATIONS ARE APPROXIMATE. EXACT LENGTH, LOCATION AND APPROPRIATE END TREATMENTS WILL BE FIELD VERIFIED AT THE TIME OF CONSTRUCTION. ADDITIONAL GUARDRAIL MAY BE REQUIRED AT LOCATIONS NOT SHOWN WHEN, IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY. WHEN GUARDRAIL IS REQUIRED, IT SHALL BE INSTALLED FOUR (4) FEET OFFSET FROM THE EDGE OF PAVEMENT TO THE FACE OF GUARDRAIL, AND ROADWAY SHOULDER WIDTHS SHALL BE INCREASED TO SEVEN (7) FEET. 5. WHERE URBAN CROSS SECTIONS ARE INSTALLED, ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT CG-9(A, B OR C). 6. WHERE RURAL CROSS SECTIONS ARE INSTALLED, ALL RESIDENTIAL DRIVEWAY ENTRANCES SHALL CONFORM TO VDOT STANDARD PE-1. 7. COMPLIANCE WITH THE MINIMUM PA VEMEN T WIDTH, SHOULDER WIDTH AND DITCH SECTIONS, As SHOWN ON THE TYPICAL PA VEMEN T SECTION DETAIL, SHALL BE STRICTLY ADHERED TO. 8. ROAD PLAN APPROVAL FOR SUBDIVISIONS IS SUBJECT TO FINAL SUBDIVISION PLAT VALIDATION. SHOULD THE FINAL PLAT FOR THIS PROJECT EXPIRE PRIOR TO SIGNING AND RECORDATION, THEN APPROVAL OF THESE PLANS SHALL BE NULL AND VOID. 9. ALL SIGNS OR OTHER REGULATORY DEVICES SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES AND THE ALBEMARLE COUNTY ROAD NAMING AND PROPERTY NUMBERING ORDINANCE AND MANUAL. 10. TRAFFIC CONTROL OR OTHER REGULATORY SIGNS OR BARRICADES SHALL BE INSTALLED BY THE DEVELOPER WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, THEY ARE DEEMED NECESSARY IN ORDER TO PROVIDE SAFE AND CONVENIENT ACCESS. 11. THE SPEED LIMITS TO BE POSTED ON SPEED LIMIT SIGNS ARE 5 MPH BELOW THE DESIGN SPEED, OR AS DETERMINED BY VDOT FOR PUBLIC ROADS. 12. VDOT STANDARD CD-1 OR CD-2 CROSS -DRAINS UNDER TO BE INSTALLED UNDER THE SUBBASE MATERIAL AT ALL CUT AND FILL TRANSITIONS AND GRADE SAG POINTS AS SHOWN ON THE ROAD PROFILES. 13. A VIDEO CAMERA INSPECTION IS REQUIRED FOR ALL STORM SEWERS AND CULVERTS THAT ARE DEEMED INACCESSIBLE TO VDOT OR COUNTY INSPECTIONS. THE VIDEO INSPECTION SHALL BE CONDUCTED IN ACCORDANCE WITH VDOT'S VIDEO CAMERA INSPECTION PROCEDURE AND WITH A VDOT OR COUNTY INSPECTOR PRESENT. ROAD NOTES GRADING: 1. THE LATEST EDITION OF THE ROAD & BRIDGE SPECIFICATIONS, THE ROAD & BRIDGE STANDARDS OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS SHALL GOVERN THE MATERIAL AND CONSTRUCTION METHODS OF THIS PROJECT. 2. WHERE UNSUITABLE MATERIAL IS ENCOUNTERED IN THE ROADWAY, IT SHALL BE REMOVED FROM THE ENTIRE ROAD RIGHT OF WAY WIDTH AND REPLACED WHERE NECESSARY WITH SUITABLE MATERIAL TO THE SATISFACTION OF THE ENGINEER. J. ALL GROWTH OF TREES AND VEGETATION SHALL BE CLEARED AND GRUBBED FOR THE ENTIRE EASEMENT. OTHER TREES AND VEGETATION WHICH OBSTRUCT SIGHT DISTANCES AT ROAD INTERSECTIONS SHALL BE REMOVED. 4. ALL VEGETATION AND OVERBURDEN TO BE REMOVED FROM SHOULDER TO SHOULDER PRIOR TO THE CONSTRUCTION OF THE SUBGRADE. DRAINA GE: 1. ALL PIPE CULVERTS, EXCEPT PRIVATE ENTRANCES, SHOWN HEREON ARE TO BE RCP WITH A MINIMUM COVER OF ONE (1) FOOT. 2. STANDARD UNDERDRAINS (CD-1 OR CD-2 OR UD-4'S) TO BE PROVIDED AS INDICATED ON THE PLANS, OR WHERE FIELD CONDITIONS INDICATE. J. ALL DRIVEWAY ENTRANCE PIPES SHALL BE A MINIMUM OF TWENTY (20) FEET IN LENGTH AND HAVE A MINIMUM DIAMETER OF FIFTEEN (15) INCHES AND SHALL BE PLACED IN ACCORDANCE WITH THE VIRGINIA DEPARTMENT OF TRANSPORTAION SPECIFICATIONS UNLESS OTHERWISE NOTED ON PLANS. 4. ALL DRAINAGE EASEMENT SHALL BE CLEARED AND GRADED TO THE SATISFACTION OF THE ENGINEER. DRAINAGE EASEMENTS SHALL EXTEND TO A POINT DEEMED AS NATURAL WATER COURSE. PA VEMEN T.- 1. AN ACTUAL COPY OF THE CBR REPORT /S TO BE SUBMITTED PRIOR TO THE PLACEMENT OF THE A GGREGA TE BASE MA TER/A L. /F THE SSV VALUES ARE LESS THAN 10, THE DEVELOPER WILL BE REQUIRED TO SUBMIT FOR ENGINEERS APPROVAL THE PROPOSED METHOD OF CORRECTION. 2. SUBGRADE MUST BE APPROVED BY THE ENGINEER FOR GRADE, TEMPLATE AND COMPACTION BEFORE BASE IS PLACED. J. TEST REPORTS ON SELECT MATERIALS MUST BE SUBMITTED SHOWING THE MATERIAL MEETS REQUIRED GRADATION FOR TYPE /, //, OR /// PRIOR TO PLACING AGGREGATE BASE. 4. THE REQUIREMENTS TO PUGMILL AGGREGATE BASE WILL BE WAIVED IN THE EVENT THAT THE SURFACE COURSE IS BEGINNING AT THE COMPLETION OF THE INSTALLATION OF THE AGGREGATE BASE. IN THE EVENT THAT THE SURFACE COURSE IS APPLIED PRIOR TO 60 DAYS, THE PUGMILL REQUIREMENT WILL APPL Y. TYPICAL ROAD SECTIONS NTS NOTES: 1. SEE PAVEMENT DESIGN CHART ON THIS SHEET FOR ROADWAY DEPTH REQUIREMENTS. 2. STREET WIDTHS SHALL BE IN ACCORDANCE WITH ALBEMARLE COUNTY AND FIRE AND RESCUE STANDARDS & WILL PROVIDE ADEQUATE WIDTHS. EXISI. EXIST. GRL __ __ EXIST. � GROUND Ad - EXIST GROUND EXIST. GROI -_j EXIST. GROUND i ALBEMARLE COUNTY GENERAL CONSTRUCTION NOTES 1. PRIOR TO ANY CONSTRUCTION WITHIN ANY EXISTING PUBLIC RIGHT-OF-WAY, INCLUDING CONNECTION TO ANY EXISTING ROAD, A PERMIT SHALL BE OBTAINED FROM THE VIRGINIA DEPARTMENT OF TRANSPORTATION (VDOT). THIS PLAN AS DRAWN MAY NOT ACCURATELY REFLECT THE REQUIREMENTS OF THE PERMIT. WHERE ANY DISCREPANCIES OCCUR THE REQUIREMENTS OF THE PERMIT SHALL GOVERN. 2. ALL MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM TO CURRENT SPECIFICATIONS AND STANDARDS OF VDOT UNLESS OTHERWISE NOTED. J. EROSION AND SILTATION CONTROL MEASURES SHALL BE PROVIDED IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN AND SHALL BE INSTALLED PRIOR TO ANY CLEARING, GRADING OR OTHER CONSTRUCTION. 4. ALL SLOPES AND DISTURBED AREAS ARE TO BE FERTILIZED, SEEDED, AND MULCHED. 5. THE MAXIMUM ALLOWABLE SLOPE IS 2. 1 (HORIZONTAL: VERTICAL). WHERE REASONABLY OBTAINABLE, LESSER SLOPES OF 3: 1 OR BETTER ARE TO BE ACHIEVED. 6. PA VED, RIP -RAP OR STAB/L/ZA TION MA T LINED DITCH MA Y BE REQUIRED WHEN IN THE OPINION OF THE COUNTY ENGINEER, OR DESIGNEE, IT IS DEEMED NECESSARY IN ORDER TO STABILIZE A DRAINAGE CHANNEL. 7. ALL TRAFFIC CONTROL SIGNS SHALL CONFORM WITH THE VIRGINIA MANUAL FOR UNIFORM TRAFFIC CONTROL DEVICES. 8. UNLESS OTHERWISE NOTED, ALL CONCRETE PIPE SHALL BE REINFORCED CONCRETE PIPE -CLASS W. 9. ALL EXCAVATION FOR UNDERGROUND PIPE INSTALLATION MUST COMPLY WITH OSHA STANDARDS FOR THE CONSTRUCTION INDUSTRY (29 CFR PART 1926). NOTE: MANDATORY INSPECTIONS AT THE FOLLOWING PHASES ARE REQUIRED FOR ROADS THAT ARE PROPOSED TO BE STATE MAINTAINED: i. INSTALLATION OF ANY ENCLOSED DRAINAGE SYSTEM BEFORE IT IS COVERED. ii. INSTALLATION OF ANY ENCLOSED UTILITY PLACEMENTS WITHIN THE RIGHT-OF-WAY BEFORE BEING COVERED iii. CONSTRUCTION OF THE CUTS AND FILLS, INCLUDING FIELD DENSITY TESTS, BEFORE PLACEMENT OF ROADBED BASE MATERIALS. iv. A FINAL PAVEMENT DESIGN, BASED ON ACTUAL SOIL CHARACTERISTICS AND CERTIFIED TESTS, SHALL BE COMPLETED AND APPROVED BEFORE THE PAVEMENT STRUCTURE IS PLACED. v. PLACEMENT OF BASE MATERIALS, INCLUDING STONE DEPTHS, CONSISTENT WITH THE APPROVED PAVEMENT DESIGN, PRIOR TO PLACEMENT OF THE PAVING COURSE OR COURSES, FOLLOWED BY FIELD DENSITY AND MOISTURE TESTS AND THE PLACEMENT OF A PAVING COURSE AS SOON AS POSSIBLE. vi. CONSTRUCTION OF PAVEMENT, INCLUDING DEPTH AND DENSITY, UPON COMPLETION AS PART OF THE FINAL INSPECTION. vii. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING VDOT A MINIMUM OF ONE WEEK PRIOR TO EACH OF THE ABOVE PHASES OF CONSTRUCTION TO SCHEDULE AN INSPECTION. viii. FAILURE OF THE CONTRACTOR TO SCHEDULE THESE INSPECTIONS WILL REQUIRE ADDITIONAL TESTING OF THE ROADS AT THE DISCRETION OF VDOT OR MAY LEAD TO THE ROADS NOT BEING ELIGIBLE FOR STATE MAINTENANCE. TYPICAL PUBLIC HATHAW.4Y STREET SECTION WITH PARTYING ON ONE SIDE (55.5' WIDTH ROW) 25 MPH IJE',� ICN S PT RD NOT TO SCE11V CC 6 In= -., CURB SIDEWALK 6' PLANTING S7RIP GUTTER TRAVEL WAY - 1.5" SM-9.5 ASPHALT TOPCOAT 7RAVn WAY CC 6 STREET TREE 1 4 " SM-9.5A SURFACE COURSE 3" BM-25 INTERMEDIATE COURSE oo °o �o 6" COMPACTED AGGREGATEooBB°D000g�°Do�°o8�°��°g�°0� BASE COURSE, VDOT #21 A o°o°��O°o°� o0 0 OR #21 B DEPENDING ON r ULTIMATE TRAFFIC LIMITS AND UNDERDRAINS D �� COMPACTED SUBGRADE ASPHALT PAVING - ROADS NO SCALE PROPOSED 1" SM-9.5� OVERLAY EXISTING PAVEMENT EX. STONE SUBBASE COMPACTED ------------ SUBGRADE ASPHALT PAVING - MILL/OVERLAY NO SCALE III�� ■�I�i � lu - ir5.262 AC ■ 1 i _r �.. • ■�■i!I■I� �■�!F■ilF� • h y� 11 oil TRIP GENERATION SCALE: 1" = 200' TRIP GENERATION CALCULATIONS TRIP GENERATION BASED ON ITE TRIP GENERATION MANUAL (8TH EDITION) TOWNHOME UNITS - CODE 230 ANOKO CT & DESOTO DRIVE (WEST): 16 UNITS PROPOSED SECTION OF HATHAWAY ST.: 28 UNITS ADT: 94 VPD (47 ENTER/ 47 EXIT) ADT: 164 VPD (82 ENTER/ 82 EXIT) AM PEAK: 7 VPH (1 ENTER/ 6 EXIT) AM PEAK: 12 VPH (2 ENTER/ 10 EXIT) PM PEAK: 8 VPH (6 ENTER/ 2 EXIT) PM PEAK: 15 VPH (10 ENTER/ 5 EXIT) DESOTO COURT & DESOTO DRIVE (EAST): 12 UNITS ADT: 34 VPD (17 ENTER/ 17 EXIT) AM PEAK: 5 VPH (1 ENTER/ 4 EXIT) PM PEAK: 6 VPH (4 ENTER/ 2 EXIT) Pavement Design RF= 1.0 Location ADT HCV Design ADT CBR SSV Dr Surface h a Base b a Sub -base h a Dp Hathaway Street 164 5 214 4 4 9.39 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21 B 5 0.6 11.75 Desoto Drive, Court & Anoko Court 94 5 144 4 4 8.01 SM-9.5 1.5 2.25 BM-25 2.5 2.15 21 A 5 0.6 11.75 Access Road- Asphalt SM-9.5 0 2.25 BM-25 0 2.15 21 A 8 0.6 4.80 CURB GUTTER 6' PLANTING STRIP SIDEWALK TYPICAL PRIVATE DPSOTO STREET SECTION WITH NO PARTYING (49 ' WIDTH ROW) 25 11PjV DI:5 0W SPZZD NOT TO SC1lLE TYPICAL PRIVATE ANOIfO COURT SECTION WITH PERPENDICULAR PARIfING (55.5' WIDTH ROW) 25 MPH DESIGN SPEED NOT TO SCALE E I T CG-2 C%L ST. GROUND HEADER CURB 1- V-- EXISTGROUND EXIST. GROUND EXIST. GROUND 6' 5' I 10' I 10' 26' 0., 1.5" SM-9.5 ASPHALT TOPCOAT ESMT CG-h CURB 0. 5, GUTTER 2' TYPICAL PRIVATE' DESOTO COURT S.F0Tf0jV #VITA PERPEjVDICULAR PARKING - 47' PRIVATE' ROAD (PRIVATE ACCESS PASFffF_1VT) 25 ffPH DESICIV SPEED , 07' TQ SCALE EXIST. GROUND EXIST. GROUND CA 8' VDOT 21A STONE SUBBASE & 2' SM-9.5 ASPHALT TOPCOAT 12' ASPHALT 7RAV£LWAY 20'ACCESS EASEMENT TYPICAL ASPHALT EfSROMWr ACCESS SECTION DRIVEIVAT SHtJZZ HINT' A 27 SUPEREIEVIITION TO THE EAST EV07' 70 .S"CALL' -_/ EXIST. GROUND EXIST. GROUND 4R. �l OSCLLINS ��0 12/3/20 �w� �1S''sI ONA _ L E�G�� H z w 0 U U) 0 � � Z > w Zz o Q � Q O U oC Q z w m Q 0 � J 0 U z O Q � w 1,-oc J o Q " > cwn w LULU wQ ce w a 0 w U) LU 0 0 0 w N N N r Q o 01 ,--I ,--I 0 Z � C'7 M N C` ) N WC:) N N WQ z LU J_ U) . ^ LU ~ 0 z J Q W Y W H Zw w Jw Jry (D C:) 0 C:) N u z J c- 0 Q 0 LL ryo 1 ^Q z 0 J_ LU 0 06 U) w 0 z L W 0 w C� _ d Ln JOB NO. 112066 SCALE AS NOTED SHEET NO. 6 CC-9D A -0, WIDTH OF UNPAVED SPACE :ESS ROUTE UNPAVED SPACE PEDESTRIAN ACCESS ROUTE DETAILS WITH & WITHOUT UPAVED SPACE ADDITIONAL RIGHT-OF-WAY IS REQUIRED IF THE LIMITS 1'-3" OF PEDESTRIAN ACCESS ROUTE ® EXTEND BEYOND EXISTING 15" OR PROPOSED VDOT RIGHT -OF WAY. ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS '�j • e PATHUNOBCONNECTINGALLEACCES AFIRM CCESLIP SIBLE EME TS OFTA FACILITY THAT CAN BE APPROACHED, ENTERED AND 1a. • A, °. USED BY PEDESTRIANS. o • o • o • e • o • o• a o• o• o XE IF PEDESTRIAN ACCESS ROUTES ® ARE BEING PROVIDED, A MINIMUM 4' TRAVERSABLE WIDTH IS REQUIRED WITH A MAX. 2/. CROSS SLOPE. SECTION B-B WHEN USED IN CONJUNCTION WITH STANDARD OR GG THE GURU FAGS ON THIS STANDARD T STANDARD IS TO BE ADJUSTED TO MATCH THE MOUNTABLE CURB CONFIGURATION. NORMAL GUTTER _----------- x ooe. 31F % TO 10% CHANGE ••o� • o . o o� s e o, o4S o4b L6 �a•o I •'�o� o. sQ 000�. • o,;aogoo4od ,a a• SECTION C-C ••Q. 4o•O• 6" AGGREGATE BASE CLASS A3 (H.E.S.) CONC. TYPE ISIZE 21B �. 12'!. MAX. SLOPE POINT OF GRADE CHANGE FOR CURB AND GUTTER ONLY �. a, n• x x 12 X MAXIMUM INCREASE IN SLOPE AT MINIMUM 10' INTERVALS p 4. FOR SIDEWALK CURB AND GUTTER * * x 3 % MAXIMUM DECREASE IN SLOPE FOR FIRST 10' INTERVAL AND BUILT CONCURRENTLY 8 % MAXIMUM DECREASE FOR SUCCEEDING MINIMUM 10' INTERVALS • * 04. o. cam. c: SECTION A -A SECTION D-D XVD❑T STANDARD ENTRANCE GUTTER SPECIFICATION REFERENCE ROAD AND BRIDGE STANDARDS SHEET 1 OF 1 REVISION DATE 502 203.03 07/15 VIRGINIA DEPARTMENT OF TRANSPORTATION GR-2, 2A A HALF PLAN �' UNPAVED.I. SIDEWALK SPACE SPACE * 27Y4" MIN - 204" MAX RAIL HEIGHT 1 1 1 GR-2 (6'-3" POST SPACING) MAX DYNAMIC DEFLECTION - 3' NOTES: GUARDRAIL LOCATIONS SHOWN ON PLANS ARE APPROXIMATE ONLY AND CAN BE ADJUSTED DURING CONSTRUCTION IF AND AS DIRECTED BY THE ENGINEER. FOR DETAILS OF POST AND BLOCKOUTS SEE SHEET N0.501.05 FOR DETAILS OF RAL ELEMENT, RAIL SPLICE JOINT, AND ASSOCIATED HARDWARE SEE SHEET NOS. 501.01 AND 501.02. RAIL ELEMENTS ARE FURNISHED SHOP CURVED FOR RADII BETWEEN 5 FEET AND 150 FEET. ALL GUARDRAIL POSTS SHALL BE SET PLUMB. POST SHALL NOT BE SET WITH A VARIATION OF MORE THAN /g" PER FOOT FROM VERTICAL. W-BEAM, BLOCKOUTS, AND POSTS SHALL BE SET AND ALIGNED WITHOUT ALTERATION OR FORCE, AS PER SECTION 505 OF THE SPECIFICATIONS. ALL GR-2 AND GR-2A RAIL SHALL BE MAINTAINED AT A HEIGHT OF 27-'4" MIN - 28Y4" MAX AS MEASURED PER STANDARD GRAINS. ALL W-BEAM RAILS SHALL BE LAPPED IN THE DIRECTION OF VEHICULAR TRAVEL FOR THE FINISHED ROADWAY. THE OPTIONAL GR-2A METHODS OF NESTING THE RAIL OR USE OF AN ADDITIONAL RAL ON THE BACK OF THE POST FOR STANDARD GR-2A SHALL BE APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. 3'-1V2" 3'-1Vz' 3' 1'/z„ J J J J J GR-2A C3'-1V2" POST SPACING) MAX DYNAMIC DEFLECTION - 2' x OPTIONAL GR-2A METHOD x OPTIONAL GR-2A METHOD USING NESTED RAIL USING ADDITIONAL RAIL ON BACK OF POST x WHEN NESTED RAL OR ADDITIONAL RAL IS PLACED ON BACK OF POST FOR GR-2A THE POST SPACING WILL BE W-3". FLARE RATES DESIGN SPEED INSIDE SHY LINE BEYOND SHY LINE MPH SHY LINE LS FLARE RATE FLARE RATE 70 9' 30=1 15=1 60 8' 26=1 14:1 * 50 6.5' 21=1 11:1 * 40 5' 16:1 8:1 * 30 4' 13=1 7:1 * SUGGESTED MAXIMUM FLARE RATE FOR SEMI -RIGID BARRIER SYSTEMS. XVD❑T A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. SPECIFICATION ROAD AND BRIDGE STANDARDS STANDARD BLOCKED -OUT W-BEAM GUARDRAIL REFERENCE SHEET 1 OF 2 REVISION DATE (STRONG POST SYSTEM) 221 501.04 08/14 VIRGINIA DEPARTMENT OF TRANSPORTATION 505 6" MIN TOP OF - CURB 4'y R 6" i v � STANDARD CG-6 CURB & GU T TER NO SCALE 7" VDOT #57,#68, OR #78 STONE BASE UNDER CURB & CHECKED BY VDOT PRIOR TO PAVING AND/OR BACKFILLING. (VARIABLE WIDTH) 4" CONC.�, 3000 psi MIN CC-12 GENERAL NOTES: 1. THE DETECTABLE WARNING SHALL BE PROVIDED BY TRUNCATED DOMES. 2. DETECTABLE WARNING SHALL BE FROM THE MATERIALS APPROVED LIST FOR DETECTABLE WARNING SUFACES. PRODUCTS NOT LISTED SHALL MEET THE REQUIREMENTS OF THE SPECIAL PROVISION FOR CG-12 DETECTABLE WARNING SURFACE AND SHALL BE SUBMITTED TO THE STANDARDS AND SPECIAL DESIGN SECTION FOR APPROVAL. 3. SLOPING SIDES OF CURB RAMP MAY BE POURED MONOLITHICALLY WITH RAMP FLOOR OR BY USING PERMISSIBLE CONSTRUCTION JOINT WITH REQUIRED BARS. 4. IF RAMP FLOOR IS PRECAST,HOLES MUST BE PROVIDED FOR DOWEL BARS SO THAT ADJOINING FLARED SIDES CAN BE CAST IN PLACE AFTER PLACEMENT OF PRECAST RAMP FLOOR. PRECAST CONCRETE SHALL BE CLASS A-4. 5. REQUIRED BARS ARE TO BE NO.5 X 8" PLACED 1-CENTER TO CENTER ALONG BOTH SIDES OF THE RAMP FLOOR, MID -DEPTH OF RAMP FLOOR. MINIMUM CONCRETE COVER 1V2". 6. CURB / CURB AND GUTTER SLOPE TRANSITIONS ADJACENT TO CURB RAMPS ARE INCLUDED IN PAYMENT FOR CURB / CURB AND GUTTER. 7. CURB RAMPS ARE TO BE LOCATED AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. THEY ARE TO BE PROVIDED AT INTERSECTIONS WHEREVER AN ACCESSIBLE ROUTE WITHIN THE RIGHT OF WAY OF A HIGHWAY FACILITY CROSSES A CURB REGARDLESS OF WHETHER SIDEWALK IS EXISTING, PROPOSED, OR NONEXISTENT. THEY MUST BE LOCATED WITHIN PEDESTRIAN CROSSWALKS AS SHOWN ON PLANS OR AS DIRECTED BY THE ENGINEER, AND SHOULD NOT BE LOCATED BEHIND VEHICLE STOP LINES, EXISTING LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. ACCESSIBLE ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A FACILITY THAT CAN BE APPROACHED, ENTERED AND USED BY PEDESTRIANS. 8. RAMPS MAY BE PLACED ON RADIAL OR TANGENTIAL SECTIONS PROVIDED THAT THE CURB OPENING IS PLACED WITHIN THE LIMITS OF THE CROSSWALK AND THAT THE SLOPE AT THE CONNECTION OF THE CURB OPENING IS PERPENDICULAR TO THE CURB. 9. TYPICAL CONCRETE SIDEWALK 15 4" THICK. WHEN THE ENTRANCE RADII CANNOT ACCOMMODATE THE TURNING REQUIREMENTS OF ANTICIPATED HEAVY TRUCK 5,1 NOTE: COMPONENTS OF CURB RAMPS CONSIST OF THE FOLLOWING: HYDRAULIC CEMENT SIDEWALK (DEPTH IN INCHES, AREA IN SQUARE YARDS) CURB WHEN REQUIRED (CG-2 OR CG-3 IN LINEAR FEET) DETECTABLE WARNING SURFACE (AREA IN SQUARE YARDS) EACH OF THE ABOVE ITEMS IS A SEPARATE PAY ITEM AND SHOULD BE SUMMARIZED FOR EACH CURB CUT RAMP. SIDEWALK RAMP 121 MAX 48.1 MAX 4`� a 10.1 MAX TYPE A PERPENDICULAR 5'MIN wrm 12:1 MAX TYP PARALLEL TRAFFIC, REFER TO STANDARD CG-13, COMMERCIAL ENTRANCE (HEAVY TRUCK TRAFFIC) FOR CONCRETE DEPTH. AT )IC , 2" HIGHER THAN 'fj EDGE OF PAVEMENT 10. WHEN CURB RAMPS ARE USED IN CONJUNCTION WITH A SHARED USE PATH, \ AT XX , SAME AS TOP OF CURB THE MINIMUM WIDTH SHALL BE THE WIDTH OF THE SHARED USE PATH. 11. WHEN ONLY ONE CURB RAMP IS PROVIDED FOR TWO CROSSINGS (DIAGONAL), TYPE C A 4' x 4' LANDING AREA SHALL BE PROVIDED TO MANEUVER A WHEELCHAIR PARALLEL &PERPENDICULAR INTO THE CROSSWALK WITHOUT GOING INTO THE TRAVELWAY. THIS 4' x 4' LANDING AREA MAY INCLUDE THE GUTTER PAN. 12. ALL CASES WHERE CURB RAMPS INTERSECT A RADIAL SECTION OF TRUNCATED DOME 6" 2.4" C-C m CURB AT ENTRANCES OR STREET CONNECTIONS THE DETECTABLE 0 WARNING SURFACE SHALL HAVE A FACTORY RADIUS OR BE FIELD 0 0 0 0 0 0 z -MODIFIED AS RECOMMENDED BY THE MANUFACTURER TO MATCH O O O O O O O O O O O O - THE BACK OF CURB. O O O O O 0 0 0 0 0 0 0 1a LANDING RAMP c� O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O N O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O = 50%-651 OF BASE DIAMETER TOP DIAMETER O O O O O O 0 0 0 0 0 0 0 0 0 DETECTABLE WARNING a AT BACK OF CURB I� _I 0.9" 1.4" I VARIABLE FULL WIDTH OF RAMP FLOOR SEE NOTE 12. r- BASE DIAMETER I- PAY LIMITS DETECTABLE WARNING TRUNCATED DOME INSTALLED ON A RADIUS DETAIL DETECTABLE WARNING DETAIL tvD❑T SPECIFICATION CG-12 DETECTABLE WARNING SURFACE REFERENCE ROAD AND BRIDGE STANDARDS SHEET 1 OF 5 REVISION DATE (GENERAL NOTES) 105 203.05 07/15 VIRGINIA DEPARTMENT OF TRANSPORTATION 502 7 GR-2, 2A 8„ W. WASHER 5/g"x18" BOLT ^} I & NUT = _ - _ - Y4" HOLE y H 74" OLE a 6"x 8"x1'-2" TREATED N1, PINE BLOCK OR 6"x6"x1'-2" �4" HOLE 3 �4„ $ RECYCLED MATERIAL, TREATED PINE BLOCK OR r 3/ RECYCLED 74 GA_V. STEEL 10D o MATERIAL COMMON NAL SEE NOTE 5. N 6„ WIDE BLOCKOUT FOR USE WHEN REPAIRING DAMAGED GUARDRAIL 6"x8"x1'-2" TREATED CONTANING STEEL BLOCKOUTS. PINE BLOCK /sue A BLOCKOUT FOR MAINTENANCE TREATED'1 REPAIR ONLY SOUTHERN PINE 7y4„ LESS THAN 1'-O„ HOLE 6x8 WOOD POST ' 'I�h 4"x 8"0-2" TREATED PINE BLOCK. STRONG POST THESTACRT POSTSTFORYPE USEIIIOWITH O TI ISIHEREHE 4�� WIDE BLOCKOUT 0" POST GUARDRAIL REQUIRED REQUIRED STFFp SPECIFIED BY THE ENGINEER IN THE PLANS. DETAIL A 74" DIA POST MAY BE HOT ROLLED OR WELDED. HOLE 04B" GUARDRAIL INSTALLATION - SITES REQUIRING LONGER - It GUARDRAIL POSTS N4„NOTES: fH'O'LES 6 EATE 2 ..10.. BOLT TREATED PINE wii& NUT 1. ALL BOLTS, NUTS, WASHERS, AND OTHER BLOCK OR 0 STEEL ITEMS ARE TO BE GALVANIZED. I-� -� I I II III11 _ I LI RECYCLED w II MATERIAL 2. ALTERNATE TYPE POSTS AND BLOCKOUT MAY I II it I I- I III � I I T -' N BE INTERCHANGED ON ANY ONE PROJECT WITH II W6x8.5 OR i THE RESTRICTION THAT THE SAME TYPE OF II W5x9 POST AND BLOCKOUT MUST BE USED IN ANY SINGLE RUN OF GUARDRAL. - II 0 OPTIONAL HOLE II TO FACILITATE t° 3. FOR DETAILS OF GUARDRAIL ELEMENT SPLICE JOINT, HARDWARE, ETC. SEE SHEET NOS.501.01 3�/z" DIA HOLES AIr-EtFII I CA VANIZING AND 501.02. 4. DRIVE NAIL BOTH SIDES WITHIN 2" OF THE TOP OR BOTT7T OM OF BLOCKOUT AFTER" x 18 tr BOLT IS INSTALLED. HOLES IN POSTS BRACKETSAND TO A T 0 BEE%4DI. CRT POST STEEL POST SPECIFICATION A COPY OF THE ORIGINAL SEALED AND SIGNED DRAWING IS ON FILE IN THE CENTRAL OFFICE. XVD❑T REFERENCE STANDARD BLOCKED -OUT W -BEAM GUARDRAIL ROAD AND BRIDGE STANDARDS 221 236 (STRONG POST SYSTEM. POST AND BLOCKOUT DETAILS) REVISION DATE SHEET 2 OF 2 505 VIRGINIA DEPARTMENT OF TRANSPORTATION 08/14 501.05 4" 21-A STONE BASE CONCRETE SIDEWALK NO SCALE Tree Planting and Staking Detail Not To Scale DOUBLE STRAND #12 GAUGE WIRE WITH RUBBER HOSE & TURNBUCKLES 2"x2" HARDWOOD STAKE CUT & REMOVE BURLAP FROM TOP 1/3 OF BALL AS SHOWN SCARIFY SUBSOIL TO 4" MIN. DEPTH MULCH SAUCER FINISHED GRADE TREES UP TO 4" CAL. SHALL BE STAKED. TREES 4" CAL. OR LARGER SHALL BE GUYED WITH 3 EQUALLY SPACED TWISTED, #12 GAUGE WIRE WITH HOSE AND TURNBUCKLES. LOOP HOSE AROUND TRUNK ABOVE BRANCHES AS SHOWN, FLAG WIRES WITH COURVEY TAPE. REFER TO SPECS FOR ADDITIONAL INFORMATION. AMENDED SOIL MIX COMPACTED SUBGRADE C� %2 WIDTH OF ENTRANCE EXISTING OR PROPOSED EXPANSION JOINT SIDEWALK OR SIDEWALK SPACE o F 2'- O" A EXPANSION JOINT J w E W JE w w ? CURB INCLUDED IN Lw) U O ENTRANCE CUTTER r as j(n 4 w w r 0 FLOW LINE EXPANSION JOINT ENTRANCE WIDTH DESIRABLE MINIMUM 16' ABSOLUTE MINIMUM 12' EDGE OF PAVEMENT HALF PLAN C WIDTH OF ENTRANCE z_ LIMITS OF PED. LIMITS OF RED. ACCESS ROUTE NJo ACCESS ROUTEEN UNPAVED SPACE NDN TRAVERSABLE -' UNPAVED SPACE FOR WIDTH OF ENTRANCE CIE LIMITS OF PED, o LIMITS OF PED. CCESS ROUTEFA NON -TRAVERSABLE -' ACCESS ROUTE PEDESTRIAN ACCESS ROUTE DETAIL WITH & WITHOUT UNPAVED SPACE ADDITIONAL RIGHT-OF-WAY IS RE IRED IF THE LIMITS 2,-0„ OF PEDESTRIAN ACCESS ROUTE M EXTEND BEYOND EXISTING OR PROPOSED VDOT RIGHT -OF WAY. ® PEDESTRIAN ACCESS ROUTES PROVIDE A CONTINUOUS UNOBSTRUCTED, STABLE, FIRM AND SLIP RESISTANT 4 0 000Q4o PATH CONNECTING ALL ACCESSIBLE ELEMENTS OF A FACILITY THAT CAN BE APPROACHED, ENTERED AND USED BY PEDESTRIANS. IF ACCESS ROUTE IS ADJACENT TO BACK OF CURB, MINIMUM WIDTH SHOULD BE 6'. SECTION F-F IF PEDESTRIAN ACCESS ROUTES ® ARE BEING 21-13" , PROVIDED, A MINIMUM 4' TRAVERSABLE WIDTH IS REQUIRED WITH A MAX. 2/. CROSS SLOPE. WHEN USED IN CONJUNCTION WITH STANDARD PARABOLIC CG-3 OR CG-7, THE CURB FACE ON THIS UNPAVED SIDEWALK CURVE STANDARD IS TO BE ADJUSTED TO MATCH THE MOUNTABLE CURB CONFIGURATION. oho 0 0�0 �• SPACE o. o .o • o• o NORMAL GUTTER---- SECTION E-E e.^ e, e o ° ot! 4.0 0.0 . * WOK TO 10% CHANGE 0 0. 0• a. ovq•RbayoR o�o.b.... V. o4a• CLASS A3 (H.E.S.) CONC. o, oo� , oYcg I 6" AGGR. BASE TYPE I SIZE 210 �• 5' 0" 12% MAX. SLOPE 5'-0" ® POINT OF GRADE CHANGE �. ' ?• p '• FOR CURB AND GUTTER ONLY NIF . ti. • u, G, FOR SIDEWALK CURB AND GUTTER x )K 12 % MAXIMUM INCREASE IN SLOPE AT MINIMUM 10' INTERVALS BUILT CONCURRENTLY Q.oa�o�ip �. o•� o SECTION C-C x x >K 3 % MAXIMUM DECREASE IN SLOPE FOR FIRST 10' INTERVAL AND B % MAXIMUM DECREASE FOR SUCCEEDING MINIMUM 10' INTERVALS SECTION D-D SPECIFICATION NVVD❑T REFERENCE STANDARD ENTRANCE GUTTER ROAD AND BRIDGE STANDARDS 502 REVISION DATE SHEET 1 OF 1 203.02 VIRGINIA DEPARTMENT OF TRANSPORTATION 07/15 1992 3.38 Source: Va. DSWC III - 401 Plate 3.38-2 OLS�� �SCOTT LINS C-) Lie. No. 035791 ~d� 12/3/20 O�,�SSIONAL E1SG��� (n H z LU O U In o 0 Z LU ZO Q z OO Q m ¢ z w Q 0 p Ln J O U z LUw L Q i Lu (/) w LULU wQ w a 0 w w cy- o O CD LU 1-- - M m ,\I N kn= W H Q 2 WLU � mu z ^J 0 (n v ' 0 J LL I- Uj �I u U) I..L pi L` 0 z z 0 Q L w O w CII _ JOB NO. 112066 SCALE AS NOTED SHEET NO. 6A ACSA GENERAL WATER & SEWER CONDITIONS (June 27, 2019) 1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE START OF THE WORK. 2. THE ALBEMARLE COUNTY SERVICE AUTHORITY SHALL HAVE ACCESS TO USE THE AIRSPACE ABOVE THE LOCATIONS OF CONSTRUCTION FOR THE FLIGHT OF UNMANNED AERIAL VEHICLES FOR THE PURPOSE OF IMAGERY COLLECTION. 3. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND STRUCTURES, AS NECESSARY. 4. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION SPECIFICATIONS, AS ADOPTED BY THE ACSA. 5. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY (1-800-552-7001). 7. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE LATERALS AND WATER LINES, ETC. 8. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE OF ROADSIDE DITCHES. 9. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE. i0. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT. ii. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO- LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4, 201-4 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT). 12. THE SEWER LATERAL BEYOND THE CONNECTION AT THE SEWER MAIN SHALL BE PRIVATE. THE SEWER LATERAL STUB -OUT SHALL UNDERGO THE ACSA LOW-PRESSURE AIR TEST TO SATISFY COUNTY TESTING REQUIREMENTS. VISUAL INSPECTION OF THE SEWER LATERAL STUB -OUT SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 1.3. THE SEWER LATERAL BEYOND THE CONNECTION AT A MANHOLE SHALL BE PRIVATE. VISUAL INSPECTION AND PRESSURE TESTING OF THE SEWER LATERAL SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 14. THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE IS PRIVATE. VISUAL INSPECTION AND TESTING OF THE FIRE SPRINKLER MAIN DOWNSTREAM OF THE GATE VALVE SHALL BE WITNESSED BY THE COUNTY BUILDING INSPECTIONS DEPARTMENT. THIS INSPECTION SHALL OCCUR UNDER AN "OTHER PLUMBING" PERMIT WHICH MUST BE OBTAINED BY THE CONTRACTOR. 1-5. ALL FLUSHING OF FIRE SPRINKLER MAINS SHALL NOT OCCUR UNTIL APPROVAL IS GIVEN BY THE ACSA. GOOD FOUNDATION MATERIAL ROCKY FOUNDATION MATERIAL ` .. d ., 624" IN6 INITIAL BACKFILL 6^24 IN 6' X MIN MIN. MIN. MIN..- 6" BEDDING #68 STCNE * STABLE SOIL ROCK * SCRAPE THE BOTTOM OF THE TRENCH. REMOVE ALL STONES TO INSURE THE PIPE DOESN'T REST ON ROCK AND THEN COMPACT THE SOIL OR PROVIDE A 4" BEDDING OF #68 STONE. FOUNDATION IN POOR SOIL UNDER -CUT CONDITION 4'MI INITIAL BACKFILL 4'MI UNSTABLE a" a" ap 8" SOIL MIN. MIN.- _ MIN MIN. 68 STONE = GRANULAR FILL A5 O. APPROVED BY ACSA 5 A8L OlL O ROCK" STABLE SOIL OR ROCK' NOTE 1, NO ROCKS SHALL BE ALLOWED WITHIN 24" OF THE WATER LINES. 2. NO ROCKS LARGER THAN 6" IN ANY DIMENSION SHALL BE ALLOWED ABOVE THE INITIAL BACKFILL. 3.THE INITIAL BACKFILL SHALL BE PLACED AND COMPACTED IN 6" LIFTS. 4. NO ORGANIC OR FROZEN MATERIAL OR DEBRIS SHALL BE ALLOWED IN THE TRENCH. 5. BELL HOLES SHALL BE DUG OUT IN ALL CASES. DUCTILE IRON WATER PIPE INSTALLATION & BEDDING NTS FIG. W-2 TD-2 JUNCTION BOXES, TRANSFORMER PADS, PEDESTALS, ETC. SHALL NOT BE LOCATED WITHIN THE RIGHT OF WAY. VARIES 5' 10' - 5' WATER SEWER 3 � 0 LOCATION OF OTHER UTILITIES (GAS, ELECTRIC, TELEPHONE, CABLE, ETC.) EASEMENT WIDTHS: WATER DR SEWER ONLY - 20' MINIMUM WATER & SEWER 30' MINIMUM SEE PART 3, PARAGRAPH D, SEPARATION OF WATER & SEWER SYSTEMS. UTILITIES CROSSING A WATER OR SEWER EASEMENT SHOULD BE AT 90° TO THE RIGHT OF WAY. UTILITY LOCATIONS & EASEMENT WIDTHS NTS FIG. W-1 TD-1 PLACE 5' GALVANIZED WITNESS POST WITH CAPPED ENDS PAINTED BLUE IN REMOTE AREAS o AS DIRECTED. MARKER LOCATION MAY BE SUBJECT ¢ TO HIGHWAY DEPARTMENT APPROVAL, FINISHED GRADE M.J. GATE VALVE WATER LINE 41 2500 PS.I. CONCRETE a 2'x 2' BEARING AREA THRUST BLOCK 4 q 4 A a NOTE IN REMOTE AREAS, VALVE BOXES SHALL EXTEND SIX (6) INCHES ABOVE GRADE, TYPICAL GATE VALVE NTS FIG- W-5 TD-9 15 1/2" E.J.I.W. 1574 CAST IRON CLEANOUT FRAME AND LID 10 1/4" INSTALLED FLUSH WITH FINISHED SURFACE CONCRETE COLLAR POURED 7 1/2" SEE PAVEMENT AROUND CLEANOUT COVER EXISTING GRADE REPLACEMENT (3500 PSI) REQUIREMENTS PVC FEMALE CLEANOUT ADAPTER WITH INVERTED NUT SCREW CAP OR FLAT SLOTTED SCREW CAP KOR-N-SEAL No. S406-10 AWS* * WITH 10 1/4" BAND PVC PIPE SEE BACKFILL AND BEDDING 45° BEND REQUIREMENTS PVC PIPE SEWER LATERAL FUTURE SANITARY LATERAL VVYE v I 'A BOTTOM OF TRENCH -"*SECTION -A' SEWER CUSTOMER'S PROPERTY EASEMENT OR RIGHT-OF-WAY FUTURE SANITARY LATERAL (WHEN INLINE LAYOUT REQ'D) .i.<` ". ` ,:;;•. CAST IRON CLEANOUT s.t.r. z2+ ter. FRAME AND LID WYE SEWER LATERAL . A CONCRETE 450 BEND " ' COLLAR PLAN VIEW STANDARD SANITARY CLEANOUT IN PAVED AREAS J 45' 2ax 45' 1 45' mox PLUG L 2 FOR ALL BENDS FOR TEE OR WYE FITTINGS WIDEN TRENCH TO ACCOMMODATE ANCHOR IF REQUIRED. rn� AS Mpr BEDDING D REQUIRED , S9 45' MIN I - SECTION 2-2 PIPE DEGREE BEND DIMENSIONS VOL. TEE AND PLUGS VOL. SIZE OF (FEET) CU.YD. (FEET) CU.YD. BEND L H T L H T 90 2.50 2.50 3.C1 0.24 4" & 6^ 45 22 1/2 2,00 1.50 2.25 2.00 2.64 2.52 4,15 0.10 200 2.25 250 0.15 11 1/4 1,50 2.00 2,50 0.10 90 3.66 3.16 3,21 0.48 191' 45 2,65 2,55 2,77 0126 22 1/2 1.66 2.16 2.69 C.13 3A 6 291 2.66 0.32 11 1/4 1,66 2.16 2.67 0.13 90 4,83 3.83 3.42 0.83 10" & 12" 45 3.33 3.58 2,95 OAZ 3.R3 4.00 2.83 0,52 22 1 /2 2,33 2.58 2.86 0,24 11 1/4 1.53 2.33 2.84 0.18 1_ THRUST BLOCKS ARE REQUIRED WHENEVER THE PIPELINE : CHANGES DIRECTIDN, CHANGES SIZE, DEAD ENDS AND AT VALVES. 2. USE 2500 P.S.I. CONCRETE. 3. NO CONCRETE SHALL BE POURED ON ANY PART OF THE JOINT. 4. THE CONSULTING ENGINEER SHALL BE RESPONSIBLE TO THE VERIFY THE TYPE & SIZE OF ALL THRUST BLOCKS. CONCRETE THRUST BLOCKS NTS FIG. W-3 TD-3 1' CCMPRESSICM rc 3/4" MALE PIPE COUPLING CH APPROVED EQUAL ❑ (D I' TYPE "K' SOFT COPPER FOR USE ON ATTAGl1ED SINGLE FAMILY RESIDENTIAL SERVICES OR DUAL RESIDENTIAL AND IRRIGATION SERVICES. I"al"nl" TEE NGTE: NO SWEATED EIr1NG4 2• DUAL SERVICE R 1" COIAPRESSION x 31C HALE PIPE OOUPLING OR APPROVED EQUAL 1' TYPE -K- $OPT COPPER (D FOk USE 0I4 DETACHED SINGLE FAMILY RESIDENTIAL SERVICE YMERE AN IRRIGATION METER 15 NOT PROVIDED, SINGLE SERVICE NOTE_ 1) SADDLES SHALL BE USED ON PVC PIPE, I/e aEND CO nmtssarcT TYPICAL SERVCE LATERAL INSTALLATION (5/8" & 1" METERS) NTS FIG. W-6A TD-10 3000 PSI CONC. BASE BENCH SLOPED TO FLOW Q CHANNEL 1/4" V MIN p ,1 BRANCH 12" W r I l 2„ FLEXIBLE CONNECTION NOTE: WITH STAINLESS STEEL ALL CONNECTIONS TO BAND EXISTING MANHOLES SHALL BE CORED AND A FLEXIBLE W J CONNECTION BOOT " o INSTALLED TYPICAL MANHOLE PLAN SHOWING BRANCH TIE - IN NTS FIG. S-I-B TD-27 NOTE: RESTRAINED JOINT FITTINGS Side View 42" Minimum LEV a' . I I' Certification of 95%11 a compaction required �- _ a a Galvanized Steel Beam, a W12 x 14 (min. size) ) z 3' min. penetration into undisturbed soil , or as approved by the q ACSA. 4' MINIMUM �1UM 45' TYPICAL THRUST BLOCK N FILL AREA NTS FIG, VV-3B TD-5 NOTEI MIN. 60' ➢IAMETER MANHOLE REQUIRED, 0 &H. 7P �P,1 OROP XAN�aLE PVC CROSS 2" USE APPROVED FLEXIBLE RUBBER BOOT. 6" L GTOP, CI➢ III srDP couPLING er J t nrkbP PIPE PIPE STRAPS - 75TAINLE55 STEEL? - 0 SPACED EVER" Z' VERTICALLY RESTRAINED BEND �'_ SEWER _ INFLUENT PIPE p p . a �� I: ' r o- � MAIN " n _ SEWER -0 ¢ r { n PIPE PLAN f+RIOFILE MIN. b' REBBING WITH F.O. FH 1,TO11E 1- HEIGHT OF THE VERTICAL DROP PIPE WILL BE DETEI I NED BY THE ACSA, BUT SHALL N DT RE LESS THAN TW O (2) FEET- 2. VERTICAL DROP PIPE SHALL BE SDR 26 RV-C,SIZED THE SAME ASTHE INCOMING PIPE AND CONNECTEDT0 THE DROP FITTING WITH STAN DA RD GASKET JOINT- 3. VERTICAL DROP PIPE SHALL BE STRAPPEDTOTFiE MANH OLE AT PIPE JOINTS. STRAP5511TALL BE MADE OF STAINLESS STEEL 4. SHAPE INVERTAS NEEDED TO PROVIDESMCX}TH TRANSTFIONFROMDROPCONNECITON DISCHARGiEP01P1F TOSPRING ONE OF MANHOLE INVERT- 5. DROP CDNNECTIDN DISCHARG E FITTING SHALL BE ORIENTED AT 45 DEGREES, INTO THE FLOI 6. VERTICAL DROP PIPE SHALL BE INSTALLED AT 90 DEGREES FROM THE ACCESS STEPS. 7. MINIMUM72" DWMETER MANHOLE REQUIRED FORA SINGLE 10" O11112" DIAMETER DROP CONNECTION, OR TWO8" DIAMETER DROP CONNECTIONS. STANDARD INTERNAL DROP CONNECTION N,T,S, FIG. S-1-C2 TD-30 `v t= N 'IF w= a E �� m tt:n N �E rc¢ a tJ� Oo �u Um 0 Ewe u w 10 0 o! w QE a Z C� eEs a�oEa O N Ez '"� ;n W w O � a F `= O U c nr ' E u �E ,E N� v0m -� O 4 4 a E .� E g E E a E U o E w N N u d 0 TYPICAL MANHOLE FRAME & COVER N.T.S FIG S-1-D TD-31 FINISHED GRADE �ITI�fT�T1T�IT ° TrrT-ITI -�r -rlr-ITI-�rT TRENCH .' REDUCER f b . *--2500 P.S.I. CONCRETE THRUST BLOCK - - - - - - - - - - - - - UNDISTURBED SOIL 8 18" MN. 4-- PROFILE VIEW UNDISTURBED SOIL - EDGE - 24" MIN. OF TRENCH 4 - - - - - - - - - - - - - - _ -4 - - - - - - °d REDUCER g' MN ° a f a� - e 25QQ P_S,I_ CONCRETE THRUST BLOCK aQ. 9" KIN. - - - -- --- -------- UNDISTURBED SOIL - EDGE �- OF TRENCH a ° 24" MN. NOTES: PLAN VIEW NOT TO SCALE • NO CONCRETE SHALL BE POURED ON ANY PART OF THE MECHANICAL JOINT. USE PLASTIC SHEETING AS PROTECTION FOR BOLTS. • 3' MINIMUM HORIZONTAL PENETRATION INTO UNDISTURBED SOIL ON BOTH SIDES OF TRENCH, OR AS APPROVED BY THE ACSA. • 3' MINIMUM VERTICAL PENETRATION INTO UNDISTURBED SOIL, OR AS APPROVED BY THE ACSA. CERTIFICATION OF 95% COMPACTION REQUIRED IN TRENCH. THE CONSULTING ENGINEER SHALL BE RESPONSIBLE TO VERIFY THE TYPE AND SIZE OF ALL THRUST BLOCKS. NTS FIG_ W-3D TD-7 [COVER LIFT NOTCH 14 1/2" 12 3/8" 12 1/2" WATER CAST IRON LID 18" METER BOX 15, ti y �N 18" 6" EXTENSION C. PIPE SLOT {2 PLACES) NOTES; (1) A 1-3/4" DIAMETER HOLE IS REQUIRED IN THE LID FOR TOUCH READ METERS. TYPICAL METER BOXES (5/8" V METERS) NTS FIG, W-7 TD-13 SEWER SERVICE LATERAL CONNECTION NOTES; 1. WHERE A SEWER SERVICE LATERAL CONNECTS TO A MANHOLE AND NO INVERT ELEVATION FOR THE SERVICE LATERAL IS INDICATED , THE TOP (CROWN) ELEVATION OF THE SERVICE LATERAL PIPE SHALL BE AT LEAST 0.2' HIGHER THAN THE TOP (CROWN) ELEVATION OF THE THE LOWEST PIPE CONNECTED TO THE MANHOLE. 2. SEWER LATERALS TAPPED INTO AN EXISTING SEWER MAIN SHALL BE CONNECTED USING A PIPE SADDLE, 3. MINIMUM GRADE FOR SEWER SERVICE CONNECTION SHALL BE 2% (1/4" PER FOOT ) �� 4. ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER 2' MIN DIAMETER OF 4". 5, ALL SEWER LATERALS SHALL HAVE A MINIMUM COVER OF 3 FEET. SALT TREATED FINISHED GROUND 2 x 4 MARKER PLUG END OF MAIN LINE SERVICE LATERAL SECTION 4sa'o" IN LINE WYE-TEE PLAN VARIES SEWER SERVICE LATERAL CONNECTION N. T. S. FIG. S-2 TD-33 NOTE: HYDRANT MUST BE EQUIPPED WITH CHARLOTTES- VILLE THREA05 WHICH 15 THE LOCAL STANDARD. 1 LENGTH OF BRANCH VARIES s' MIN 2' TO 10' (270'} 7 CU. FT. 3'- 22"VALVE BOX #68 STONE 42°MIN 6" CATE %:, VALVE +" TEE 25CO P.S,I. CONCRETE BASE AND THRUSTi' BLOCK AGAINST UNDISTURBED STABLE SOIL. STEEL PILE RESTRAINED JOINT FITTINGS WHEN THE SOIL IS DISTURBED OR WHEN A HYDRANT IS LOCATED IN A FILL, IN ADDITION TO POURING CONCRETE, A STEEL PILE SHALL BE USED AS ADDITIONAL SUPPORT. NOTE 1. SURROVND WEEP HOLES WITH GRAVEL AND KEEP FREE OF CONCRETE. 2. MAINTAIN A 3 1/2' MIN. COVER FROM THE MAIN TO THE FIRE HYDRANT { INCLUDING DITCHES ) 3. FINISHED GRADE SHALL SLOPE AWAY FROM THE FIRE HYDRANT AND VALVE BOX. 4. THE GATE VALVE IS ALLOWED IN SHOULDER OR BEHIND THE DITCH. IT IS NOT ALLOWED IN THE DITCH. 5, FIRE HYDRANTS SHALL BE INSTALLED AT LOCATIONS WHERE WEEP HOLES ARE AHOVE THE PREVAILING GROUNDWATER ELEVATION. IF REQUIRED TO BE IN WET AREAS, THE WEEP HOLES SHALL BE PLUGGED AND THE HYDRANT SHALL BE PUMPED DRY. TYPICAL FIRE HYDRANT ASSEMBLY DETAIL N.T.S. FIG, W-4 TD-8 (SHED GRADE AIR RELEASE VALVE BRONZE GATE BRASS OR BRONZE PIPE VALVE DRAIN TO GRADE li F POSSIBLE III -II. I�III ' I -1I I-1I II BRICK SUPPORTS OR I � III-1II-1I SOLID CEMENT BLOCK$ CRUSHED STONE TYPE "K" SOFT A7CORPORATION COPPER STOP N O TES_ 1) A PRECAST MANHOLE CONE AND COVER WITH WATER CAST ON LID FOR TRAFFIC AREAS, OR A METER BOX ASSEMBLY IN NON -TRAFFIC AREAS, OR APPROVED EQUAL, SHALL BE USED. 2) FOR WATERLINES SMALLER THAN 12" USE A 1" A.R.V. AND FITTINGS. FOR WATER LINES 12" AND LARGER USE 2" A.R,V. AND FITTINGS. 3) IN SITUATIONS WHERE THE A.R.V. ASSEMBLY CANNOT BE OFFSET FROM THE MAIN AN ADEQUATE FOUNDATION SHALL BE INSTALLED SO THE WATER LINE DOES NOT SUPPORT THE MANHOLE CONE. AIR RELEASE VALVE (ARV) NTS FI G. W- 9 ID-20 REMAINING BACKFILL SHALL NOT CONTAIN ROCK MATERIAL 36"MIN LARGER THAN 5" IN ANY DIMENSION 24"MI INTIAL BACKFILL* 8"MIN (6" LIFTS) EMBEDMENT * THOROUGHLY COMPACTED SPRING LINE BY HAND OR APPROVED OF PIPE MECHANICAL TAMPER HAUNCHING NO. 68 STONE BEDDING 6" may 4" min FOUNDATION (SHALL BE REQUIRED WHEN SOIL CONDITIONS ARE UNSTABLE ALL PIPE) NOTE 1. OPEN CUTS IN PAVED AREAS WITHIN EXISTING VDOT RIGHT-OF-WAY SHALL BE HACKFILLED ENTIRELY WITH NO. 21A STONE. 2. FOR DUCTILE IRON PIPE THE BOTTOM OF THE TRENCH SHALL BE SCRAPED AND COMPACTED, AND ALL STONES REMOVED OR A 4" BEDDING OF NO, 68 STONE SHALL BE PROVIDED 3. WHERE ROCK IS ENCOUNTERED PIPE SHALL BE INSTALLED ON A MINIMUM 6" BEDDING OF NO. 68 STONE TYPICAL SEWER PIPE NSTALLATION IN TRENCH NTS FIG. S-3 TD-34 0FT� SCOTR. LLINS C-) Lie. No. 035791,� ~d� 12/3/20 O�,�SSIONAL E1SG��� z W O U O ZZ � > w z Z O Q � Q 0 tI U 0 _ � H z w m U 0 J O U Q w W > I I > Ln W W W > W co J 0I Q 0� Y� W CE 0 LU > W cy- O CD CD LU N N N l� Q ,M-I O \ ,\i N L9 N I 0 N N w Q z > Q L J J 101- \J / 0 W Q co O O �I ® u 06 wI I- LU Q p z 0 W ui Q I..L U) Jw III J V 0 0 N w w w a � JOB NO. 112066 SCALE AS NOTED SHEET NO. 7 HIGH PT STA: 10+01.56 HIGH PT ELEV: 685.85 PVI STA:10+24.06 PVI ELEV:685,50 K: 13.32 LVC: 45.00 cD Ln co 0 Ll� 00 Lc� LO o� `� Co �co +� +(_0 O 0 �w �w U u > U > HIGH PT STA: 11+71.20 m � LLI LOW PT STA: 11 +59.82 PVI STA: 12+11 20 PVI S A: T-r 9.82 INTERSECTION OF PVI ELEV: 681.0 PVI ELEV:679.98 HATHA AY STREET K: 27.86 : 21.67 L C:80.00 (STA 1 +96.75) AN LV :100,00 DESOTO DRIVE (STA 00 685 -1. 2% •01 2.4 675 PROPOSED 6"X6" TEE (2) 6" G.V. 670 cow Q0•0 \ 0� rl� 0 C�'Co +(Q0 o w. \�w U C_D9 > v m-4.90% >-) m 4" = _7 3.5' . PROPOSED FIRE HYDRANT MIN. ASSEMBLYw/6"x6"TEPROPOSED VDOT (2) 6" G STD. CD-2 _3 1 PROPOSED 4" SANITARY SEWER LATERAL (TYP.) Q0 ••I w EXISTING GRADE (TYP.) w 685 680 ROPOSED GRADE (TYP.) PROPOSED VDOT STD. CD-1 675 - p 'FILL TO BE PLACED AT 1 95%COMPACTION (TYP.) PROPOSED 15" STORM o p 1 5 4" DUCTILE IRON SEWER CROSSING SANITARY SEWER LATERALS 670 PROPOSED 45' S VERTICAL BEND 7 2 I - 1. 2' PROPOSED 8" SANITARY SEWER CROSSING PROPOSED 12"x6l' CROSS, PROPOSED 45' 665 t(1)12 G.V. & (2) 6 G.V. VERTICAL BEND 665 PROPOSED 6" CL. 52 DI WATERLINE PROPOSED 15" STORM SEWER CROSSING PROPOSED (1) 6" G.V. TYPE A BLOW -OFF 660 ASSEMBLY 660 M 00 M N ci O^ M 00 a) O 0 L. ul N l0 L!1 00 ' lD 00 lD N 00 N m l0 O 00 00 00 lD Ol p M l0 00 Ln 10 u! 1m 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 DESOTO DRIVE PROFILE 700 700 EXISTING GRADE (TYP.)---,\ LOW PT STA: 10+53.03 LOW PT ELEV: 685.95 PVI S A:10+63.48 695 PVIELEV: 685.36 695 L\ C: 115.00 Q / o c9 PROPOSED GRADE (TYP.) 00 690D 00 w m 685 PROPOSED 8" ROOF DRAT CROSSING 680 3.4° PROPOSED (1) 6" G.V. TYPE A BLOW -OFF +uo 690 w u 'w 53% 3.5' MIN. 685 PROPOSED VDOT STD. CD-2 ASSEMBLY o 0 p o 0 675 PROPOSED 6"x6" TEE, (2) 6" G.V. PROPOSEID 6" CL. 52 DI WATERLINE- 670 9+50 680 1 PROPOSEDGF PROPOSED (1) 6" G.V. & TYPE A BLOW -OFF o ASSEMBLY FIR, 675 (1)1 PROPOSED 4" SANITARY BL SEWER LATERAL (TYP.) AS rn r 0D Ln 00 00 6 O N � N ^ 06 1D00 1D � 10 � � 10+00 10+50 11 +00 11 +50 12+00 ANOKO COURT PROFILE 670 12+50 720 720 715 715 710 710 HIGH PT S A: 12+51.8 HIGH PTELEV: 679.87 PVI ST :12+55.30 PVI ELEV: 680.03 705 K: VC- 12.22 40 00 705 ouo 0­t LOW P7 STA: 11+16.94 ' �D LOW PT ELEV: 680.18 `_' °� `- 06 Fl- PVI TA: 10+66.9 N �o N �_o 700 PVI ELEV: 680.82 w w 700 LVC: 100.00 m w > > j) � � OW PT STA: 11+92. W u 0 LOW PT ELEV: 679.4 695 cc ++ `o w 00 + CO PVI STA: 1 +94.12 695 K: 28.57 un > C) �w > LVC: 75.00 >m m EXISTING GRADE (TYP.) 690 = -J 690 AIDE (TYP.) PROPOSED VDOT =Z STD. CD-2 L > O m z > w 685 \ 0 685 I e 11 )POSED S w 00 G.V. & 0 U) (.6TYPE A ° Ld Ln + DW-OFF z_ iEMBLY 680 680 3.5' ° MIN. PROPOSED 8" PROPOSED VDOT ROOF DRAIN 2' STD. CD 2 TIE-IN TO EXISTIW CROSSING 675 675 4A 1.5' PROPOSED FIRE HYDRANT ASSEMBLY w/ 12"x6" TEE 1 .5' (1)12" G.V. & (1) 6" G.V. PROPOSED 15" STORM 670 670 SEWER CROSSING PROPOSED 12"x6" CROSS, REMOVE EXISTING 12" E (1)12" G.V. & (2) 6" G.V. &TIE -INTO EXISTING 1: WATERLINE PROPOSED 15" STORM PROPOSED 8" SANITARY 665 SEWER CROSSING 665 SEWER CROSSING PROPOSED 12" CL. 52 DI WATERLINE 660 660 N Nraq. n 1. 1^ 00 n NI. 00 M 0 LDLD 0000 �t 'i 1D O 00 lD Ql ^ lD Ql n lD Ql n 10 lD 1D 10 1D lD 1D 9+50 10+00 10+50 11 +00 11 +50 12+00 12+50 HATHAWAY STREET PROFILE VERTICAL GRAPHIC SCALE 5 0 2.5 5 10 ( IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. 20 200 3GRADE S.O.V. DI 13+00 13+50 NOTE: SANITARY LATERALS CROSSING OVER WATERLINE SHALL HAVE ADEQUATE STRUCTURE SUPPORT FOR THE SEWERS TO PREVENT EXCESSIVE DEFLECTION. IN ADDITION, THE LENGTH OF THE WATERLINE SHALL BE CENTERED AT THE POINT OF THE CROSSING SO THAT JOINTS SHALL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE SEWER. THE LENGTH OF THE SEWER PIPE SHALL ALSO BE CENTERED AT THE POINT OF THE CROSSING, SO THAT THE JOINTS SHALL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATERLINE. NOTE: ALL ROADWAY EMBANKMENT MATERIAL SHALL CONSIST OF SOIL AND BE PLACED IN SUCCESSIVE UNIFORM LAYERS NOT MORE THAN 8 INCHES IN THICKNESS BEFORE COMPACTION OVER THE ENTIRE ROADBED AREA IN ACCORDANCE WITH VDOT 2007 ROAD AND BRIDGE SPECIFICATION 303.04 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. NOTES: 1. ALL FILL TO BE PLACED AT 95% COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF 1' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. SC0)TT R. LLINS77' Lic. No. 035791 12/3/20 o��ssI0NAL ' 1SA � Z w c C Z z o _j a p�r0 U m u Q a w J w H z o Q F a u z '-' Q w c `u W > w cn > w a C c u 0 0 0 w N N N < M M o � o z LU w ry J� w AM U) z J Q LL J �O 0 Q W O z � J i ry W oC � � z z < O� Q 0� H- w H r w O w cr_ _ a JOB NO. 112066 SCALE 111 = 501 SHEET NO. 8 d z w w z z W z J J 0 c� 0 0 U W Q x 0 a 0 U 0 U 0 �o 0 U L 0 U 0 N 0 U c 0 a 0 Q Q T a 0 0 u) a Q 0 0 _0 0 U 7 O Q N 0 a E _0 a z W w z z W U) z J J 0 0 0- 0 Q u) U X O E U 0 _0 -a 0 _o U 0 u) O 0 V) a Q 0 V) 0 HIGH PT STA: 10+16.85 HIGH PT ELEV: 670.81 PVI STA:10+34.40 PVI ELEV:670.99 K: 2.45 LVC: 40.00 o 0� 0119 LOW PT STA: 11 +47.01 o 4 F-' LOW PT ELEV: 654.19 + Ln co + CO cfl PVI STA: 11+22.01 0 O PVI ELEV:657,59 W U U K: 29.76 nn,7-- _ i > > i yr . �n nn 670 0 o LOW PT TA: 12+49. 8 670 LOW PT ELEV: 642.2 ° ° + + PVI STA: 12+09.88 o PVI ELEV: 645.63 O K: 15.24 - 665 �s Lv: 80.00 665 00 > > 00 r- 00 LOLLJ Lu 00 O 00 N ° 0) CO Ln 0) ' N + CO + � N 660 Cn m U W 660 u m W FILL TO BE PLACED AT HIGH PT STA: 1 2 59.34 95% COMPACTION (TYP.) HIGH PT ELEV: 41.49 PO STA:12+7 .34 655 PROPOSED VDOT VI ELEV:639.81 655 STD. CD-i ' LVC: 40.00 7 Q0 Ln 0- A 650 650 PROPOSED GRADE (TYP.) N „ N.- LLJ STA: 13+91.96 U U LOW P1 ci> > cis w LOW PT m ELEV: 621.91 > > PVI TA: 13+66.9 m LLJ PVI ELEV:625.79 645 K: 105.87 645 Q00) EXISTING GRADE (TYP.) o_' 1- VC: 50.00 o_' N N + C0 + 640 ° u u 640 PROPOSED VDOT > m> w STD. CD-2 m w 635 635 °o ° 630 FILL TO BE PLACED AT 630 95% COMPACTION (TYP.) 625 625 620 620 LOW P STA: 16+4 .54 \ LOW PT PVI ELEV: 593 TA:15+68.5 24 PVI ELEV: 594.49 K:10.82 HIGH P STA: 17+0 25 VC:150.00 HIGH PT ELEV: 592.29 615 PVI TA:17+17.7 615 Ln K: 6.61 o VC:35.00 + CC + .04 am Qo Ln o-� Ln oo NN N� 610 Cn � o N Ln rl� 0� 610 > --00-) > W F- F- LLJ LLJ U > m> U Um UW 605 m `L 605 600 600 595 PROPOSED VDOT 595 STD. CD-2 1.67� PROPOSED VDOT STD. CD-1 590 590 FILL TO BE PLACED AT 95% COMPACTION (TYP.) 696g ° PROPOSED VDOT 586 STD. CD-i I 5 M L!1 ^ O Ln l0 M Ql 00 ri n rl N ^ N N Ln ri Ln l0 ko l0 O N Ol LD M H 00 l0 It O 00 rn r.. O � ri M Ln N n 00 l0 O O l0 00 O U) l0 l0 O Lf1 L.0 N M Ln L!1 N n -t �t L.0 N M 00 M N O O N N �t O H N LD N O l Ol Ln Ol O Li) Ql �t � 0') r i 00 M Ol N Ol l6 00 00 lD l0 l0 L.0 lO lO LD l0 �t LD L.O ko l0 LD lO LD lO r l0 l0 to Ln Q) L!1Ln 0)Ol Ln Ln Ln u L01 ul 9+50 10+00 10+50 11 +00 11 +50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 17+99.50 PR VATE DRIVE PROFILE 5 50 ••01 ••f 685 HIGH PT STA: 10+ 2.02 685 PVI STA: 10+72. 6 PVI ELEV:674.78 K: 17.30 LVC: 140.00 680 680 0 0 + QD W W U .. U w 675 m ; 675 LLJ FILL TO BE PLACED AT 1.70 670 95% COMPACTION (TYP.) ° 670 PROPOSED GRADE (TYP.) 665 EXISTING GRADE (TYP.) 665 660 660 655 655 650 650 O lD 't 00 N O N M ci ri N lO l0 �p l0 t.p l0 i'p l0 l0 10+00 10+50 11 +00 11 +50 12+00 12+50 DESOTO COURT PROFILE VERTICAL GRAPHIC SCALE 0 2.5 5 10 ( IN FEET ) I inch = 5 ft. HORIZONTAL GRAPHIC SCALE 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. 20 200 NOTE: ALL ROADWAY EMBANKMENT MATERIAL SHALL CONSIST OF SOIL AND BE PLACED IN SUCCESSIVE UNIFORM LAYERS NOT MORE THAN 8 INCHES IN THICKNESS BEFORE COMPACTION OVER THE ENTIRE ROADBED AREA IN ACCORDANCE WITH VDOT 2007 ROAD AND BRIDGE SPECIFICATION 303.04 NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. NOTES: 1. ALL FILL TO BE PLACED AT 95% COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. SC0)TT R. LLINS7' Lic. No. 035791 1�0Als��IOIVAL 12/3/20' 1SA � Z Zz O Q Lu � 0 r 0 1■�1 � w m Q Q 0 -1z w �■■� o Q FLu a o LV w > Lu O O O W N N N M M Q 16 R 11 Z rn C) C`7 N cY) i N m N N Q w J_ w O J 2 U w U) Lu mow/ VJ w Q CD O (N w J ILL O n� I..L C) Q O H- W r, LL O w cr_ _ JOB NO. 112066 SCALE 111 = 50 SHEET NO. 9 6 z w w z z w z J J 0 0 0 U c .3 V) W Q O a 0 L 0 U O a a �o 0 U L O U O N 0 U c O 0 Q Q T a 0 O u) Q 0 0 -0 0 U O Q 0 a E -0 a z w w z z w U) z J J O C� 0 Q O Q u) U 0 E 6 U O -0 (D U 0 u) 0 0 a Q 0 Q) 710 705 700 EXISTING GRADE (TYP.) r7 I 695 I a_ � �o I> _ =Q / N 00 69000 o a- � ^ 1 CO .. ZZ ro 0 :Z � coz0 685 > �� ~ a�z o II >> ;�z � a-> > zz 680 675 670 665 660 8" SDR-26 PVC 122.19 LF 0.50% N 1n � 1 I = = =::E O : O � O 'n C10 't o I� NCO = 00 r0 co co .. Cho 0 \ g00z Z0 a_> �a_»>Vy �Z vn �- Z Zz ROPOSED GRADE (TYP.) PROPOSED 12" WATERLINE CROSSING 26 parPROPOSED DR 0 5°O% 15" STORM SEWER CROSSING PROPOSED 15" STORM SEWER CROSSING 1 26 p� C S" DR 2.34% Ql W ^ Q l0 �O 01 01 ^ N �Ol 01 lD 01 CO O p O .1.0 D O a) l ri 1.000 t a) Z0 M D 00 -0+50 0+00 0+50 1 +00 1 +50 2+00 2+50 3+00 3+50 4+00 MH-4 TO EX MH PROFILE 710 705 700 695 690 685 680 675 670 665 660 710 705 EXISTING GRADE (TYP.) ��I 700 = _� :2 :EO O O~ � rn� Ln roles 695 r r- r� = 00 Z Cfl z z0 F- a_ > 690 PROPOSED GRADE (TYP.) 685 PROPOSED 8" ROOF DRAIN CROSSING 6 8 C' 4' 2.8' PROPOSED 6" 6 p�C WATERLINE CROSSING 8" SDR_6? 2 p1% C2 9774LF 675 1 670 665 660 N ^ . Ol 000 71 705 1 r) = 700 5 O Ln Crl- � 695 Ln00(0 I � LO 00 D coo 0 II ��z 690 -0+50 0+00 0+50 1 +00 675 1 670 1 6651 MH-5 TO MH-3 PROFILE 710 705 700 695 690 685 680 710 705 700 �TH 0�p SCOTT R. LLINS,-7' Lic. No. 035791 12/3/20 o�,�ssI�NAL E1SG��� I I U F 695 Coo Cv C QCfl l C =0 =� EXISTING GRADE (TYP.) z c ~ � Q �� O� Cfl z J g C r- — - = 690 Z - o _ -L I� I�CO CVN � m Q N O Ln CO CO .. Q N� V) D U C F- r w cn Q = ap ZZ , \ I Co .. 00 in-i 0� z z0 a = ,n Q ,_, u o r �_»> z0 o cn�z zz ��>> ��� 685 > > � L �ZZ I (D FL-: Lu OfLu Lu > a = r\ D Qc ` (.O O C ICI > c Cl) I z 680 PROPOSED GRADE (TYP. 675 III 8" SDR-26 PVC 670 62.68 LF @a 0.50% 78:"SDR--.26 PVC 55.65 LF @a 0.50% 665 660 r\ O M ^ O 00 01 O 00 01 l0 00 �D rl l0 �p Cp l0 0+50 0+00 0+50 1 +00 1 +5C MH-6 TO MH-2 PROFILE VERTICAL GRAPHIC SCALE 5 0 2.5 5 10 20 ( IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. 675 670 665 660 NOTES: 1. ALL FILL TO BE PLACED AT 95% COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF 1' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 2113, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. 0 0 0 N N W N < M M O Q \ ---i rn cri N O 1 N Q z > Q � w J w J � J J Fl_ � o o Q w � O � w _ w U � Lr) w Q Q U I U) � z z O Q U, w > w Q C0 Jw J01� 0 0 0 N H- w H w O w a I W JOB NO. 112066 SCALE 1„ = 50, lw L SHEET NO. 10 710 710 710 710 705 700 STR:5 VDOT STD. DI-313 (L=6') TP=675.97 INV IN: 667.57 TO 6 INV OUT: 667.47 TO 5A 695 690 Cn 685 'n=0 0 00-0 N Or_ I- Cn Ln Ln O lli co p N(0 (0 680 Co > 00(o (0 N LO .. Z LO (DZ ZO >> U) z z 705 EXISTING GRADE (TYP.) C° I I PROPOSED GRADE (TYP.) ;' 0 700 STR:8 VDOT STD. DI-3B (L=6') (° TP=681.52 _ p 0 INV IN: 671.18 TO 9 m N INV IN: 674.00 TO C4 C/) 00 INV OUT: 671.08 TO 7 I NO o 00 cfl Q �o O O~ O NCO p 695 II `I o o Sao > �FL: 0007 N 00r_ COD ('00 m �° 0 0 00 °�� °'C P az Co p 0 0� 0)� -� I_m (0z zo 690 o o 0� r-o p ,l, �LO � 00 00 ....D 0) (DE: ZU cn � z zz O� H 0`o `off � � »> o > � Cl) I-Z zz Cn ''°° � z zo 685 ~ °0(D co � II 000(o.. > U) �z zz PROPOSED 4" SANITARY r • D SEWER LATERAL (TYP.) PROPOSED 6" (Dz0 U) �zz / WATERLINE I­__zz PROPOSED 12" CROSSING 680 WATERLINE CROSSING 1 ' -r1 PROPOSED 8" SANITARY 1 SEWER CROSSING 675 4.1' 1° ° 675 0 ° ° 15" RCP 0 FILL (TYv 1.2' 62.29 LF ® 2.47% 15" RCP 6 7 0 75.52 LF 0 1.69% 670 TIE-IN TO 2' 15" RCP SWM FACILITY E)ro% 39.00 LF ® 1.00% INV=665.50 O 44 LF 15" RCP 665 �5" R®P3 00% 63.95 LF 0 1.00% 5� 18 �-F PROPOSED 6" WATERLINE CROSSING 15" RCP 15" RCP 6.59 LF ® 4.00% 27.97 LF ® 4.00% 660 655 665 655 705 STR:10 VDOT STD. DI-3B (L=6') TP=683.78 INV IN: 677.28 TO 11 INV IN: 679.80 TO 12 INV OUT: 677.18 TO 9 695 EXISTING GRADE (TYP.) 690 PROPOSED GRADE (TYP. 685 705 N 700 J U ") O p mo 695 O F­00 (0"? Oz00 O p N 000 > Nco D 690 co zo �>> � Fzz 680'-' 680 4.3' 15" RCP 43.78 LF ® 3.61 % 675 675 PROPOSED 4" SANITARY SEWER LATERAL (TYP.) 670 670 N W rn W 0+50 0+00 0+50 STR-12 TO STR-10 PROFILE 690 690 710 STR:13 VDOT STD. DI-3C (L=10') 700 TP=679.88 INV IN: 671.89 TO 14 INV IN: 676.20 TO A2 INV OUT: 671.79 TO 9 J 695 O 00 o -0 O _ ---- o o L? �� 690 rn 0 or�F-(.0 > -1- co cow . :. . rn (0z zo �> F__z zz 685 EXISTING GRADE (TYP.) PROPOSED G ADE (TYP.) 680 PROPOSED 6" 710 705 700 695 U p O N 690 N O (.0(D > �.. r,D a-> 685 U) I­__Z 680 WATERLINE CROSSING PROPOSED 12" WATERLINE CROSSING 675 675 4.2' 670 L PROPOSED 8" SANITARY SEWER CROSSING 665 0+00 1.5'� 1' 670 15" RCP 36.00 LF ® 0.89% 15" RCP 665 122.46 LF ® 0.50% N O 00 M M a O 0 O m '5' rl 0+50 1+00 1+50 STR-14 TO STR 9 PROFILE 700 700 STR:7 VDOT STD. DI-3B (L=6') TP=678.91 INV IN: 671.54 TO 15 695 INV IN: 670.44 TO 8 INV OUT: 670.34 TO 6 m EXISTING GRADE (TYP.) I� r 0 690 0 690 In CIO O C:)cfl >O. 00 685 Ln �� 685 > Cn �z 680 1 1 680 675 675 PROPOSED GRADE (TYP.) PROPOSED 6" WATERLINE CROSSING 670 Lj 670 15" RCP 28.07 LF ® 1.00% 665 665 rn 00 00 �o 0+00 0+50 STR-15 TO STR-7 PROFILE L!1Ln Ln 01 N O �O M O M r, N ' 00 l0 l0 lD kD L!1 l.0 � Ol rj l�0 � N '4 N 00 l000 l0 � l0 kD 685 685 0+00 0+50 1 +00 1 +50 2+00 2+ 50 .5 1 00 3+50 4+00 � U STR-11 TO SWM 1 PROFILE °0 M Q E wo 680 oo� o 0'30 �� O p N� �O > 00 O o0� p 17 (.0 Q N > O co 675 ��z z� _07 5 >> II>> -VERTICAL GRAPHIC SCALE C/) z zz I�zZ 5 0 2-5 s 10 20 670 670 PROPOSED GRADE (TYP.) 665 665 EXISTING GRADE (TYP.) 15" RCP 64.33 LF CAD 0.99% 660 660 FILL TO BE PLACED AT 95%COMPACTION (TYP.) 655 655 650 1 1 650 rn o � k.0 110 0+00 0+50 STR-16 TO STR-5A PROFILE ( IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE 50 0 25 50 100 200 ( IN FEET ) 1 inch = 50 ft. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 12' OR GREATER SHALL HAVE SAFETY SLABS IN ACCORDANCE WITH STANDARD SL-1 AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTE: HDPE CAN BE USED AS AN ACCEPTABLE SUBSTITUTE FOR RCP FOR THE DRAINAGE PIPES. SEE DETAIL ON SHEET 17 FOR HDPE PIPE BEDDING INFORMATION. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 4' OR GREATER SHALL HAVE STEPS IN ACCORDANCE WITH STANDARD ST-1AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTES: 1. ALL FILL TO BE PLACED AT 95% COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF i' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE zS AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. SCOTT R. LLINS'7 �J Lic. No. 035791 12/3/20 w� IONAL Z z� c - Z z w o Ln m � u w Lu J a wLu z Q u z Q c W Lu Lu ' a u 0Lu 0rlj 0 � rn rn o01 � o Lu rn Zrl- � M 0) N C'7 I C] w 0') N N W Q z w J J W J_ > L.L w Q O O ry z� ' w Q = I~ U � ,w w ^ I `w rQ' 1 Ili O � z � U) O Lr) w > Z w Q Cn Jw J� Q 0 O C) N U W r , ui w a- U) JOB NO. 112066 SCALE 11 1= ^Ol SHEET NO. 11 c� z w w z 0 z W z J J 0 0 E E 0 U N �. .3 co Q) Q X 0 a U) 0 U L 0 0 U 0 0 �o cn cn a� 0 0 0 Cl Cn 0 0 J U CD J a 0 J c2 z w w z z w U) J 0 10 > X N ID 0 U 0 J L J C_ a a •0� 67 67 PROPOSED GRADE (TYP. FILL TO BE PLACED AT 95% COMPACTION (TYP Q 'to O~ � ISO O �O >0) c° 00 � Ln '' r7 (0 —0 zz —0+75 —0+50 0+00 0+50 1 +00 1 +50 2+00 2+50 3+00 3+50 4+00 SWM 1 TO OUTFACE PROFILE N 680 N �o 0 0� 4'4N 675 � 00 010 O-0cp o�co co.. >o D ZZD �—a-»> ~Zzz 670 ,— — 665 SEE VSMP PLAN FOR —SWM 1 DETAILS 660 \_15" RCP 11.84LF@� E.56% 4+50 5+00 5+50 6+00 •i• 675 PROPOSED GRADE(TYP FILL TO BE PLACED AT 95% COMPACTION (TYP.) 670 TIE-IN TO SWM FACILITY INV=665.50 665 XISTING GRADE (TYP. 655 650 —0+50 N 00 N (.0 J N U � � I Cn O Cn O O~ F— �—rn (n O O o �� > �co � r� .. ��z0 �> > z 0+00 0+50 685 685 680 680 675 675 PROPOSED GRADE (TYP.)— FILL TO BE PLACED AT 95% COMPACTION (TYP.) 670 670 TIE-IN TO SWM FACILITY INV=665.50—\ 665 655 650 STR-17 TO SWM-1 PROFIL 665 N O N J — 3' 685 � —o o 0 680 > r__ co O II Cn F-z 675 XISTING GRADE (TYP.)--,/z 665 15" RCP 5.06 LF @ 8.00% 660 66 655 655 650 650 N l0 l0 o 0+50 0+00 STR-18 TO SWM-1 PROFILE VERTICAL GRAPHIC SCALE 5 0 2.5 5 10 ( IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch = 50 ft. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 12' OR GREATER SHALL HAVE SAFETY SLABS IN ACCORDANCE WITH STANDARD SL-1 AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTE: HDPE CAN BE USED AS AN ACCEPTABLE SUBSTITUTE FOR RCP FOR THE DRAINAGE PIPES. SEE DETAIL ON SHEET 17 FOR HDPE PIPE BEDDING INFORMATION. NOTE: ALL DRAINAGE STRUCTURES WITH A DEPTH OF 4' OR GREATER SHALL HAVE STEPS IN ACCORDANCE WITH STANDARD ST-1 AS FOUND IN THE 2oo8 ROAD AND BRIDGE STANDARDS. NOTES: 1. ALL FILL TO BE PLACED AT 95% COMPACTION. 2. MINIMUM 3.5' OF COVER MUST BE MAINTAINED OVER W/L. 3. MINIMUM OF 1' OF VERTICAL SEPARATION FROM STORM SEWER & W/L AND 1.5' OF SEPARATION BETWEEN W/L & SANITARY SEWER MUST BE PROVIDED. NOTE: CLASS I BACKFILL MATERIAL SHALL BE CRUSHER RUN AGGREGATE SIZE NO. 25 OR 26, AGGREGATE BASE MATERIAL SIZE 21A OR 21B, FLOWABLE FILL, OR CRUSHED GLASS CONFORMING TO THE SIZE REQUIREMENTS FOR CRUSHER RUN AGGREGATE SIZE 25 AND 26, PER VDOT ROAD AND BRIDGE SPECIFICATIONS, SECTION 302.03G. 2C kR.LLlNS7' SCOT Lic. No. 035'791 12/3/20 o�,�ssI�NAL E1SG��� Ln z Zz O Q w � O a - O 1■�1 w m a Q in J w z o Q � a Ln Lu W w > Lu 0 0 0 w N N N m < M M Q O � ri ri Vol Zw w �1 H- w H r, w O w a � JOB NO. 112066 SCALE 1„ = 50, SHEET NO. 12 C� z w w z z w z J J 0 c� 0 0 U C .3 co Q O a U) 0 U L W 0 U 0 C a �o 0 co L co C O U O N O C a > U C L > O a U) 0 Q Q T a O 0 0 Q 0 0 �o a U O Q 0 a E _o a c� z w w z z w U) z J J C� 0 L Q O Q V) U X 0 z E 6 U O _o U O a a 0 co E Q Q) Q) -------------------------- STIR. - - -- ---- _--- - 680- - � /68� 684 __--------------__ 11 - - - 686- - -68o N30 Q T42"E 220.1_4 - - _ 10 _ - - z 6866 _ - 9 BS 86\ B6 8 6g°�8x - - - - - - - - - - 8 N O N r N r aor r rnr r I® (092 -- o O O 684 � No 0 o- _ 0 1 �o x / 7 iI x / \ 5 x \ \ II P 0L'P.T x /l 5A oilio N / 8 - rn - (ate 6 �\- nRry_eTE �, �o / / / / / AV A SWM 1 cP � x -k x 12 {, 11 C) / / v A \ SWM 1 I I C2 G. o r--- / A v v A \ 4A i (0c f wo - 00 � i0 --- I SWM 1 _ e I -' I - ry v I 4 �0 ----- � A2 ,�692�- IC ------------ Ego 6g°�688a - - - - - _ _ _ - - - - - - 3A \ -- ---- - �� ! m=686-68 _ _ - _ -�682684 = - - _ - - \ 682�680- - - - - - _ - - - _ 3B - - - - - HATHAWAY STREET \ 3C V A I ® r \ \ \ \ \ \ \ a Ir / DB.3291\PC. 607 UBLIC w 3D � 14 • \ \ \\ \\ D2 D1 8 -- -- - ---- 5 -.S -5 \s -- - -- - _----- 2 Sh, - --------------------� - � E1 l I \ _ -- OUT vv vv \VA\ 684 �D3 �r(O� // �v v - - v- - --- �0 15 - co - _ _ / v 12 \ 10 �9 J� -- 682 - O t ---- "O - � 6 00 (^, r I ~ I �o 10 L�jcb - E2 10 14 0 6 4 O 6� v v vv A I� I li o\i A i 13 v 6` N9 E S - - E3 9 vv vv 74_ DS �6/4 - - ��'� �� _ / �--- ---- 15 v \ `6- \ \ \\ 6170 --674 // __ _/ -- - - - -- - 7 v v v v v I DESOTO COURT- \ - 668 47 At WE ACCESS -EA SWXMT - - // 16 -6660 14 / -- -- - __ - ------ 5A - _-664--- --- 668-67°^- - -- - G] �\ / / / --- \-- - - - -- 17 \ -662 666-66 a`° 4-662 ��`' :;: -Go \\ \\ / // //--- / �/ / / / / --- SWM-1 5 6 c '-� bb2 6S�\� --/ / -----/ \ ---- 54- . 6 _ ---�/ / / / / SWM-1 v roc,° 66° 3 \ 52 ----- v 65 ��`� - - - - 9 - S o - _ ---- ------ / (� \ \\ 25 -- - ----_ (0 6 = - \ - - - - \ 24 -__ -646 652 4644 - \\ J / \ ,---------- 644 \ 650---b42- -642 G- 1648 _ -V1t ,v � � v _ -- _ - = vv -64o � 3A--638- --�` -_- \\ 642 '' 636 v �'-__ --------- 638 41 / �\-640 63$ 634 \� \ -636 T- x &3� C W 30 v 6 v 630- 3 - - 311 34 \� �``�� 662 - \--- - _ 1 1 -- /- 6 _ - _ --_-- -/ -- - - , n 1 62 -63o 3°-- \ \ - -nT....•:::::.;.:.:.:::....:.:..�. o N::.....624- - - --------- :•..: 3C .........:•.... 620 23 -�-o J \ °8 vvv -616 A/�� �o> 3 \ v� /'0-v / v / v - - - T 6, f -_v \ / 610 / 602 60 94 Y -----__ vv - 604- / mn, SWM / / / /`V) \/��1r i s96 �--604-- / / / �o i � v� V -602- 1 592 598-592' S9° \ v 592 - v �96 / / / 588 $10 i I 92 CA IT \ \ 590- 24 P \ --v P 5$6 \y'�--------- / - - \ / \ v --584, �L,00 Ln DRAINAGE DESCRIPTIONS ROOF DRAIN AND YARD INLET DESCRIPTIONS PIPE INFORMATION INLET INFORMATION IIA. in.) LENGTH (ft.) SLOPE (%) INVERT 114VERT IN OUT MATERIAL INLET TYPE: Curb Type SLOT LENGTH RIM ELEVATION Upstream Structur Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope DI-3C CG-6 6' 686.79 15 62.29 C 678.82 77.28 RCP DI-3B CG-6 6' 683.78 15 75.52 C 677.18 075.90 1RCP Al Inlet 12" 686.62 680.00 A2 684.49 677.87 8" 53.20 HDPE 4.00% DI-3A CG-6 4' 681.40 A2 Inlet 12" 68449 677.87 STR-13 679.87 676.20 8" 22.49 HDPE 4.00% 15 39.00 C 671.57 671.18 RCP DI-313 CG-6 6' 681.60 15 63.95 1.00% 671.08 670.44 RCP Upstrea Structur Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope DI-3B CG-6 6' 678.91 15 60.44 2.56% 670.34 668.79 RCP DI-313 CG-6 6' 675.95 131 Cleanout 12" 687 08 685.00 A 7 686.91 684.12 8" 44.00 HDPE 2.00% 15 27.97 4.00% 668.69 67.57 RCP 132 Cleanout 12" 686.91 684.12 A8 686.36 683.54 8" 28.98 HDPE 2.00% DI-313 CG-6 6' 675.97 15 51.78 2.99% 667.47 s5.s2 RCP B3 Cleanout 12" 686 36 682.70 A9 687.36 682.38 8" 52.71 HDPE 0.60% MHA CG-6 - 672.82 134 Cleanout 12" 687.36 682.38 STR-12 685.40 681.96 8" 69.58 HDPE 15 6.59 3.95% 1 665.76 1965.50 1 RCP 15 17.55 115.95% 665.50 62.70 1 RCP M H-1 671.44 15 9.10 15.93% 661.89 660.44 RCP M H-1 670.41 M H-1 670.95 15 11.84 4.56% 659.00 58.46 RCP M H-1 670.41 15 65.65 8.73% 652.46 46.73 RCP M H-1 658.93 15 67.47 8.00% 640.73 35.33 RCP M H-1 644.09 15 61.78 8.00% 629.33 24.39 RCP M H-1 629.13 15 60.87 8.00% 616.43 11.56 RCP MH-1 615.79 15 63.92 7.99% 602.99 597.88 RCP M H-1 602.63 15 87.75 3.35% 592.88 589.94 RCP M H-1 593.69 15 91.28 1 1.5196 587.62 i86.24 RCP M H-1 591.17 15 23.79 1.01 % 586.14 85.90 RCP 15 1 43.78 1 3.61 % 1 681.38 1 679.80 1 RCP 15 36.00 0.89% 672.21 71.89 RCP 15 122.46 0.50% $71.18 RCP 15 1 28.07 1 1.00% 1 671.82 1 $71.54 1 RCP 15 1 64.33 1 0.99% 1 667.14 1 $66.50 1 RCP 15 1 13.42 1 4.40% 1 666.09 1 $65.50 1 RCP 15 1 4.66 1 8.58% 1 665.90 1 $65.50 1 RCP 5 1 53.94 1 2.78% 1 587.00 1 585.50 1 RCP Structure Are a (Acres) Cw tc (M in.) 1 0.00 0.90 5.0 2 0.00 0.90 5.0 SWM 2 0.00 0.90 5.0 3 0.00 0.90 5.0 3A 0.00 0.90 5.0 3B 0.00 0.90 5.0 3C 0.00 0.90 5.0 3D 0.00 0.90 5.0 4 0.00 0.90 5.0 4A 0.00 0.90 5.0 SWM 1 0.00 0.90 5.0 5 0.08 0.83 5.0 5A 0.00 0.90 5.0 6 0.09 0.83 5.0 7 0.08 0.85 5.0 8 0.03 0.70 5.0 9 0.28 0.66 5.0 10 0.08 0.78 5.0 11 0.08 0.79 5.0 12 0.25 0.76 5.0 13 0.25 0.54 5.0 14 0.11 0.68 5.0 15 0.30 0.76 5.0 16 0.16 0.68 5.0 17 0.32 0.71 5.0 18 0.11 0.85 5.0 24 0.00 0.90 5.0 25 0.00 0.90 5.0 OUT 0.00 0.90 5.0 Upstrea Structure Downstream Rim Pipe I Pipe Pipe Pipe Type Rim Elevation Invert Invert Structur Size Structur Elevation Diameter Length Material Slope 135 Inlet 12" 685 683.13 136 686.41 682.87 8" 44 HDPE 0. 60% 136 Inlet 12" 68641 682.87 63 686.36 682.70 8" 28.03 HDPE 0.60% Upstream Structur Type Structure Size Rim Ele ation Invert Downstre Structur C1 Inlet 12" 685.67 683.67 C2 C2 Cleanout 12" 686.00 682.78 C3 C3 Inlet 12" 685.73 682.11 C4 C4 Inlet 12" 685.56 677.34 STR-8 Upstream Structur Type Structure Size Rim Elevation Invert Downstre Structur D1 Inlet 12" 683.37 679.83 D2 D2 Cleanout 12" 684.66 678.45 D3 D3 Inlet 12" 68158 676.50 D4 D4 Inlet 12" 678.43 673.63 D5 D5 Inlet 12" 675.77 671.02 STR-17 SC.In op TTT R. LLINS� Lic. No. 035791 12/3121 SIDNAL Z � Rim Pipe Pipe Pipe Pipe Z w 2 Invert Elevation Diameter Length Material Slope O ' U G z o > j J Q � z v ' Q a � o ; U') is 686.00 682.78 6" 32.25 HDPE 2.75% 685.73 682.11 6" 24.44 HDPE 2.75% 685.56 680.72 6" 50.64 HDPE 2.75% 681.82 674.00 6" 83.4 HDPE 4.00% W w w Rim Pipe Pipe Pipe Pipe Invert Elevation Diameter Length Material Slope F i 684.66 678.45 8" 23.38 HDPE 5.90% 681.58 676.50 8" 33.01 HDPE 5.90% 678.43 673.63 8" 48.61 HDPE 5.90% 675.77 671.02 8" 44.31 HDPE 5.90% 671.64 667.17 8" 65.29 HDPE 5.90% DI-3C CG-6 12' 685.38 Upstream Structur Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope DI-3C CG-6 6' 679.47 Li Inlet 12" 679 80 677.05 E 2 679.51 674.63 8" 44.00 HDPE 5.50% E2 Inlet 12" 679 51 673.88 E3 675.83 671.79 8" 38.02 HDPE 5. 50% DI-3C CG-6 10 679.88 E3 Inlet 12" 1 675.83 1 671.04 STR-16 671.03 668.11 8" 53.32 HDPE 5.50% Upstream Structur Type Structure Size Rim Elevation Invert Downstream Structure Rim Elevation Invert Pipe Diameter Pipe Length Pipe Material Pipe Slope DI-313 CG-6 6' 678.90 19 Inlet 24" 649.50 643.00 20 1 635.5 631.69 8" 122.09 1 HDPE 9.26% DI-3C CG-2 6' 671.03 20 Inlet 24" 635.5 626.34 21 615.5 612.83 8" 112.61 HDPE 12.00% 21 Inlet 24" 61 .5 610.55 22 605.50 602.83 8" 67.01 HDPE 11.52% 22 Inlet 24" 605.50 602.06 23 600.61 597.27 8" 49.71 HDPE 9.64% DI-3C CG-6 6' 671.64 23 I n I et 24" 600 61 595.21 23A 593.43 590.59 8" 91.35 HDPE 5.39% 23A Cleanout 24" 593.43 590.59 SWM-2 590.47 590.47 10" 11.82 HDPE 1.00% DI-3C CG-6 6' 671.77 24" HDPE RISER - - SEE DETAIL DRAINAGE AREA DESCRIPTIONS Drainage Area Area (Acres) Cw Al 0.15 0.54 A2 B1 0.14 0.90 132 B3 134 B5 136 C1 0.12 0.60 C2 C3 C4 D1 0.20 0.60 D2 D3 D4 D5 El 0.17 0.65 E2 E3 19 0.18 0.40 20 0.15 0.50 21 0.08 0.53 22 0.33 0.41 23 0.00 0.00 23A 0.00 0.00 GRAPHIC SCALE 50 0 25 50 100 ( IN FEET ) 1 inch - 50 ft. 400 0 0 0 w N N N f f M M rN N N w Q Zw w _ � O O N I t11 z z o Q J C) D Q J OQ U C) z I -I Q Q Q a- W z � z IC) I- LU LU O w a JOB NO. 112066 SCALE 111 = 501 SHEET NO. 13 d Z I,J w z Z w z J J 0 0 N C 0 U C .3 co 0 a x Q) O a O U D 0 U 0 C U a 0 U L 0 U O 0 U C L O Z 0 0 Q L Q T O 0 0 V) 0 U) Q 0 0 -0 U O L Q 0 E -0 C z w w z z w U) z J J 0 0 0 0 Q 0 a U X 0 0 U O -0 O 0 U 0 0 C O V) E C) 0- Q) Q) Table 7: Grade Inlet Design Table H 0� SCOTT R. LLINS '" Table 6: Sump Inlet Design Tabl Lie. No. 035'791 � 12/3/20 loNaL 0-1 H z w O - for inlets draining to stormwater management facilities, where overland flow to facilities is not available, 100% capture is required at 6.5in/hr i- Table 7: Grade Inlet Design Table z o > LU Zz O Q � Q O a OU IY m Q z w U) Q O p J °C U z O Q W o w J Q > > w LU wQ W W d w (n * gutter longitudinal slope of 0.001 should be used in a sump condition > rate inlets 9 ( DI-7 in o en avement ) p p reas will not have a curbs read but will have inlets read and de th p p p w for inlets draining to stormwater man gement facilities, the 6.5in/hr check storm will suffice for the 10yr conveyance to the facilities NOTE: Inlet size for structures determ ned by overland flow. Pipes have been sized to include overland flow as well as yard inlet and roof drain drainage areas. Design Storm Year = 10 Design Yeara 10 Project: Avon ParkII Job #: 182156 P�epared by: LMW, PEI O CD CD INLET M M STATION � ri ri L9 1 Z� C'� M IIIIIIIIIIIIIIIIIIIIIIIIIIIII� N C'7 W� O N W Q z Q J Zw z J CL O Q w J L9O 0C O V i J Q Q I--i _ � V U W � ''Wrr1� V `w 1 `QQ ' ti z � z in 1 1 1 O o w Z w � (n IIIIIIIIJ w IIIIIIIIIJ rQ V N U LU W a U) JOB NO. 112066 SCALE 11 � _ 0. SHEET NO. 14 INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannings Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet m w N m Q ,C o U - � � v C n O � N �_ U � N p U N C Q O > ?� 07 (A -O O U N i > O w c a� U o o c o o ° 3 o o m a o ° Y O U (0 3 Ol x Q II cn N U f6 C O � � � U w � C i a > J ¢ U U cn H w m (n (n J J W CT CT U 5 3B 6.0 0.08 0.83 0.066 0.27 0.13 0.40 0.0619 0.0200 2.0 0.0830 4.1500 3.36 0.99 3.5120 0.1463 0.1649 6.60 0.91 0.99 0.39 0.01 18 6 3B 6.0 0.09 0.83 0.075 0.30 0.00 0.30 0.0619 0.0200 2.0 0.0830 4.1500 3.01 0.99 3.5120 0.1463 0.1649 5.84 1.03 1.00 0.30 0.00 - 7 3B 6.0 0.08 0.85 0.068 0.27 0.00 0.27 0.0480 0.0200 2.0 0.0830 4.1500 3.05 0.92 3.5120 0.1463 0.1546 5.41 1.11 1.00 0.27 0.00 - 8 36 6.0 0.03 0.70 0.021 0.08 0.00 0.08 0.0380 0.0200 2.0 0.0830 4.1500 2.05 1.00 3.5120 0.1463 0.1663 2.95 2.04 1.00 0.08 0.00 - 10 36 6.0 0.08 0.78 0.062 0.25 0.00 0.25 0.0490 0.0200 2.0 0.0830 4.1500 2.94 0.99 3.5120 0.1463 0.1649 5.05 1.19 1.00 0.25 0.00 - 15 3B 6.0 0.30 0.76 0.228 0.91 0.00 0.91 0.0480 0.0200 2.0 0.0830 4.1500 4.80 0.89 3.5120 0.1463 0.1502 9.15 0.66 0.85 0.78 0.13 5cn INLETS ON GRADE, DESIGN (CURB SPREAD AND INLET CAPTURE) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannings Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet a m w N N Vl N � Q Q � � C O U � � C � w w � C v O � N w � •io CV +, o N �. N a � � � .�• v, L N � U W � O U N C U m 3 _ w c m � o O o 0 3 U � �_ � o o � m � � L � m m � cn +� � � � � m rn cso � m � o � - m � m :? m c `. � x � °� 3 `m o Y O O U c (0 7 � � � Q � N � � U C O � � � to II II J C i Q -Q C1 x 3 3 0 3 a� a > � Q U U CJ Ci cn cn � cn cn H w co in � � J ui C7 C7 U IY 5 3B 6.0 0.08 0.83 0.066 0.43 0.40 0.83 0.0619 0.0200 2.0 0.0830 4.1500 4.42 0.92 3.5120 0.1463 0.1546 9.32 0.64 0.84 0.70 0.13 18 6 3B 6.0 0.09 0.83 0.075 0.49 0.00 0.49 0.0619 0.0200 2.0 0.0830 4.1500 3.62 0.97 3.5120 0.1463 0.1619 7.27 0.83 0.96 0.47 0.02 17 7 3B 6.0 0.08 0.85 0.068 0.44 0.00 0.44 0.0480 0.0200 2.0 0.0830 4.1500 3.66 0.97 3.5120 0.1463 0.1619 6.45 0.93 0.99 0.44 0.00 - 8 3B 6.0 0.03 0.70 0.021 0.14 0.00 0.14 0.0380 0.0200 2.0 0.0830 4.1500 2.46 1.00 3.5120 0.1463 0.1663 3.61 1.66 1.00 0.14 0.00 - 10 3B 6.0 0.08 0.78 0.062 0.41 0.00 0.41 0.0490 0.0200 2.0 0.0830 4.1500 3.53 0.98 3.5120 0.1463 0.1634 6.23 0.96 1.00 0.41 0.00 - 15 3B 6.0 0.30 0.76 0.228 1.48 0.00 1.48 0.0480 0.0200 2.0 0.0830 4.1500 5.76 0.84 3.5120 0.1463 0.1429 11.56 0.52 0.73 1.09 0.40 5 - for inlets draining to stormwater management facilities, where overland flow to facilities is not available, 100% capture is required at 6.5in/hr ®---__1__-_I--- 1 11 •1 10 1 1 1 1• 1 1 1 1 1\ \ • 1 \: `1 • ' • • 11 ® 1 1 1 111' 1 11 ®1 1 1 Table 6: Sump Inlet Design Table INLETS IN SUMP, DESIGN (CURB SPREAD AND INLET SPREAD AND DEPTH) Intensity 4.00 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannings Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet o- N N U (0 N � (0 � C � � w O N a O O N O. O) O > � p O) N Y c � d u o a o U s m � � (0 f0 C C C @ N N (0 N � C N "O .m N V y � Y J F O f0 � 30 V O � `p- O` 30 � O- N � Q y � O) V1 L y E Q all 0.28 0.66 0.185 0.74 0.00 0.74 0.0010 0.0200 2.0 0.0830 4.1500 9.17 0.62 STR 9 DI-3A 4.0 combined flow 0.7 0.19 0.406 9.31 all 0.08 0.79 0.063 0.25 0.00 0.25 0.0010 0.0300 2.0 0.0830 2.7667 4.76 0.84 STR 11 DI-3C 6.0 combined flow 0.3 0.07 0.152 2.32 all 0.25 0.76 0.190 0.76 0.00 0.76 0.0010 0.0100 2.0 0.0830 8.3000 14.29 0.54 STR 12 DF3C 12.0 combined flow 0.8 0.09 0.199 9.12 all 0.25 0.54 0.135 0.54 0.00 0.54 0.0010 0.0100 2.0 0.0830 8.3000 12.57 0.56 STR 13 DF3C 10.0 combined flow 0.5 0.08 0.179 8.20 all 0.11 0.68 0.075 0.30 0.00 0.30 0.0010 0.0100 2.0 0.0830 8.3000 10.07 0.67 STR 14 DF3C 6.0 combined flow 0.3 0.08 0.170 7.78 all 0.16 0.68 0.109 0.44 0.00 0.44 0.0010 0.0190 2.0 0.0830 4.3684 7.76 0.70 STR 16 DF3C 6.0 combined flow 0.4 0.10 0.218 5.25 all 0.32 0.71 0.227 0.91 0.00 0.91 0.0010 0.0500 2.0 0.0830 1.6600 5.59 0.73 STR 17 DI-3C 6.0 combined flow 0.9 0.11 0.236 2.17 all 0.11 0.85 0.094 0.37 0.01 0.38 0.0010 0.0500 2.0 0.0830 1.6600 4.01 0.87 Carryover from STR-5 STR 18 DI-3C 6.0 combined flow, 0.4 0.09 0.199 1.82 "gutter longitudinal slope of 0.001 should be used in a sump condition - rate inlets in open pavement areas will not have a curb spread, but 9 (DI-7) p will have inletspread and depth p - for inlets draining to stormwater management facilities, the 6.5in/hr check storm will suffice for the 10yr conveyance to the facilities NOTE: Inlet size for structures determined by overland flow. Pipes have been sized to include overland flow as well as yard inlet and roof drain drainage areas. INLETS IN SUMP, DESIGN (CURBS READ AND INLET SPREAD AND DEPTH) Intensity 6.50 (Intensity is 4 in/hr for spread, and 6.5 in/hr for capacity and depth) Mannings Coefficient, n is 0.013 Inlet Hydrology Curb and Gutter Inlet a x d in d ° @ w N p- � O C � d d 'm o o ° S a '� m °� � o 0 3 � � o g 3 � @ o � a � @ m O .3 � u �, � @ � � iu � m � a Y � � � v C O �-° s u11, E m a � > � Q U Q U C'1 d C'1 vS . x cn >i 3 � 3 cn r 0 w -o � -o r d � al 0.28 0.66 0.185 1.20 0.00 1.20 0.0010 0.0200 2.0 0.0830 4.1500 11.00 0.52 STR 9 DI-3A 4.0 combined flow 1.2 0.26 0.562 12.87 al 0.08 0.79 0.063 0.41 0.00 0.41 0.0010 0.0300 2.0 0.0830 2.7667 5.71 0.79 STR 11 DI-3C 6.0 combined flow 0.4 0.10 0.210 3.20 al 0.25 0.76 0.190 1.24 0.00 1.24 0.0010 0.0100 2.0 0.0830 8.3000 17.14 0.43 STR 12 DI-3C 12.0 combined flow 1.2 0.13 0.275 12.60 al 0.25 0.54 0.135 0.88 0.00 0.88 0.0010 0.0100 2.0 0.0830 8.3000 15.08 0.44 STR 13 DI-3C 10.0 combined flow 0.9 0.11 0.247 11.33 al 0.11 0.68 0.075 0.49 0.00 0.49 0.0010 0.0100 2.0 0.0830 8.3000 12.09 0.60 STR 14 DF3C 6.0 combined flow 0.5 0.11 0.234 10.75 al 0.16 0.68 0.109 0.71 0.00 0.71 0.0010 0.0190 2.0 0.0830 4.3684 9.31 0.60 STR 16 DF3C 6.0 combined flow 0.7 0.14 0.301 7.26 al 0.32 0.71 0.227 1.48 0.02 1.50 0.0010 0.0500 2.0 0.0830 1.6600 6.70 0.54 Carryover from STR-6 STR 17 DF3C 6.0 combined flow 1.5 0.15 0.327 3.00 al 0.11 0.85 0.094 0.61 0.13 0.74 0.0010 0.0500 2.0 0.0830 1.6600 4.81 0.79 Carryover from STR-5 STR 18 DF3C 6.0 combined flow 0.7 0.14 0.310 2.84 POINT DOWNSTREAM STRUCTURE DRAIN AREA RUNOFF COEFF. CA INLET TIME RAIN FALL RU OFF Q INVERT ELEVATIONS LENGTH SI,OPF, DIA CAPA- CITY VEL FLOW TIME RF.MARK.S INCR AC UM ACRES C MIN MIN C F.S. UPPER I,OWF.R FF,F,T FT./FT. INCHES C.F.S. F.P.S. SEC 11 0.08 0.79 0.06 0 06 5.00 6.67 0.4 10 678.82 677.28 62.29 0.0247 1515.9 10 0.08 0.78 0.06 0 32 5.27 6.58 2.1 9 677.18 675.90 75.52 0.0169 15 8.4 5.6 13.5 9 0.28 0.66 0.18 0 71 5.84 6.40 4.5 8 671.57 671.18 39.00 0.0100 15 6.5 5.7 6.9 8 0.03 0.70 0.02 0 73 5.95 6.36 4.7 7 671.08 670.44 63.95 0.0100 15 6.5 5.7 11.2 7 0.08 0.85 0.07 1.03 6.14 6.31 6.5 6 670.34 668.79 60.44 0.0256 15 10.3 8.9 6.8 6 0.09 0.83 0.07 110 6.25 6.28 6.9 5 668.69 667.57 27.97 0.0400 15 12.9 10.7 2.6 5 0.08 0.83 0.07 117 6.29 6.27 7.3 SA 667.47 665.92 51.78 0.0299 15 11.2 9.7 5.3 SA 0.00 0.90 0.00 128 6.38 6.24 8.0 SWM 1 665.76 665.50 6.59 0.0395 15 12.8 11.0 0.6 SWM 1 0.00 0.90 0.00 0 00 5.00 6.67 .8 SEE SMP FOR SWM I ROUTINGS 4A 665.50 662.70 17.55 0.1595 15 25.8 16.9 1.0 4A 0.00 0.90 0.00 0 00 5.02 6.66 .8 4 661.89 660.44 9.10 0.1593 15 25.8 16.9 0.5 SWM 1 0.00 0.90 0.00 0 00 5.00 6.67 .8 SEE SMP FOR SWM I ROUTINGS 4 665.50 662.70 17.55 0.1595 15 25.8 16.9 1.0 4 0.00 0.90 0.00 0 00 5.02 6.66 5.8 3 652.46 646.73 65.65 0.0873 15 19.1 13.5 4.9 3 0.00 0.90 0.00 0 00 5.10 6.63 5.8 3A 640.73 635.33 67.47 0.0800 15 18.3 13.1 5.2 3A 0.00 0.90 0.00 0.00 5.18 6.61 .8 3B 629.33 624.39 61.78 0.0800 15 18.3 13.1 4.7 3B 0.00 0.90 0.00 0 00 5.26 6.58 .8 3C 616.43 611.56 60.87 0.0800 15 18.3 13.1 4.6 3C 0.00 0.90 0.00 0 00 5.34 6.56 .8 3D 602.99 597.88 63.92 0.0799 15 18.3 13.1 4.9 3D 0.00 0.90 0.00 0 00 5.42 6.53 .8 2 592.88 589.94 87.75 0.0335 15 11.8 9.6 9.2 2 0.00 0.90 0.00 0 00 5.57 6.48 .8 1 587.62 586.24 91.28 0.0151 15 7.9 7.1 12.9 1 0.00 0.90 0.00 0 00 5.79 6.42 5.8 OUT 586.14 585.90 23.79 0.0101 15 6.5 6.0 4.0 12 0.25 0.76 0.19 019 5.00 6.67 1.3 10 681.38 679.80 43.78 0.0361 15 12.3 6.3 6.9 14 0.11 0.68 0.07 0 07 5.00 6.67 0.5 13 672.21 671.89 36.00 0.0089 15 6.1 3.0 12.2 13 0.25 0.54 0.14 0 21 5.20 6.60 1.4 9 671.79 671.18 122.46 0.0050 15 4.6 3.2 38.0 15 0.30 0.76 0.23 0 23 5.00 6.67 1.5 7 671.82 671.54 28.07 0.0100 15 6.5 4.3 6.5 16 0.16 0.68 0.11 O11 5.00 6.67 0.7 SA 667.14 666.50 64.33 0.0099 15 6.4 3.4 18.8 17 0.32 0.71 0.23 0 23 5.00 6.67 1.5 SWM 1 666.09 665.50 13.42 0.0440 15 13.5 7.2 1.9 18 0.11 0.85 0.09 0.09 5.00 6.67 0.6 SWM 1 665.90 665.50 4.66 0.0858 15 18.9 6.9 0.7 25 0.00 0.90 0.00 0.00 5.00 6.67 7.4 SEE SMP FOR SWM 2 ROUTINGS 24 587.00 585.50 53.94 0.0278 15 10.8 9.4 5.7 705 700 695 690 HT. OF OBJ=3.5' 685 680 675 670 665 EXISTING GRADE (TYP.) I� Ol N Lf1 N c-I • 01 00 N 0 a) Ol 00 M Ol ci Ol ci Ol N Ol lD l00 lD 00 kD l00 l0 00 �kD 0+00 0+50 1 +00 1 +50 2+00 705 700 1 695 1 685 SIGHT TANCE=280' HT. OF 680 OBJ=3.5' 675 670 665 Ln ^ l0 00 Ln m 00 lD �p l0 -.0 2+50 3+00 3+50 4+00 DESOTO DRIVE (WEST) 8c HATHAWAY STREET INTERSECTION SIGHT DISTANCE PROFILE PROFILE 700 700 695 695 EXISTING GRADE (TYP.) 690 690 HT. OF �T �ISTq/vG�IT OBJ=3.5' \N� op� 1 00' SIGHT LINE (TYP.) 685 �o .A) 685 � SIGHT — — — — — DISTANCE=280' HT. OF — — — — — 680 YE=3.5' 680 HT. OF OBJ=3.5 PROPOSED GRADE (TYP.) 675 675 670 670 I� 00 0) N M rn O 00 4 coo 't M 0 M 110 6o 000 � 00 rn w O 00 00 N W � LD � I'D � tZ 110 tD � � � W 0+00 0+50 1 +00 1 +50 2+00 2+50 3+00 3+50 4+00 DESOTO DRIVE (EAST) 8c HATHAWAY STREET INTERSECTION SIGHT DISTANCE PROFILE PROFILE An 0 SCOTT R. LLINS 7 �J Lic. No. 035791 12/3/20 w� SIONAL ' 1SA � Z Z � Zzo a LU o i 1■■1 w m a Ln J a W z Q I (n Z LU LULU> > Lr)� LU o O o W N N N r � Q01 I O 01�i N N wCD N N wQ z w J_ in z LLI w jw 0 VERTICAL GRAPHIC SCALE 0 N 5 0 2.5 5 10 20 ( IN FEET ) 1 inch = 5 ft. HORIZONTAL GRAPHIC SCALE 50 0 25 50 100 200 ( IN FEET ) 1 inch = 50 ft. AN Ln LU J_ LL z o Q J 0L w Q V Q z Q O LL I —I LL � Q z p z � O V � LU Q � w z H w W O w a JOB NO. 112066 SCALE ill = 501 SHEET NO. 15 c� z w w z c� z w z J J U 0 0 U C N co Q O a 0 U C O U L O C a cn Z7 a� 0 c� U 0 0 Q J O 0 J Ul J 0 T) 0 LL 0 U z w w z ( z w U) J, O 0 0 CL x 0 U c� cn 0 J L J a� County of Albemarle Conservation Plan Checklist - To be placed on Landscape Plans (Handbook, pp III-284-111-297 for complete specifications) 1. The following items shall be shown on the plan: U Trees to be saved; ® Limits of clearing (outside dripline of trees to be saved); ® Location and type of protective fencing; ® Grade changes requiring tree wells or walls; U Proposed trenching or tunneling beyond the limits of clearing. 2. Markings: LI All trees to be saved shall be marked with print or ribbon at a height clearly visible to equipment operators. U No grading shall begin until the tree marking has been inspected and approved by a County Inspector. 3. Pre -Construction Conference: U Tree preservation and protection measures shall be reviewed with the contractor on site. 4. Equipment Operation and Storage: U Heavy equipment, vehicular traffic and storage of construction materials including soil shall not be permitted within the driplines of trees to be saved. 5. Soil Erosion and Stormwater Detention Devices: U Such devices shall not adversely affect trees to be saved. 6. Fires: U Fires are not permitted within 100 feet of the dripline of trees to be saved. 7. Toxic Materials: U Toxic materials shall not be stored within 100 feet of the dripline of trees to be saved. 8. Protective Fencing: ® Trees to be retained within 40 feet of a proposed building or grading activity shall be protected by fencing. U Fencing shall be in place and shall be inspected and approved by a County Inspector prior to grading or construction. 9. Tree Wells: U When the ground level must be raised within the dripline of a tree to be saved, a tree well shall be provided and a construction detail submitted for approval. 10. Tree Walls: ® When the ground level must be lowered within the dripline a tree to be saved, a tree wall shall be provided; and a construction detail submitted for approval. 11. Trenching and Tunneling: U When trenching is required within the limits of clearing, it shall be done as faraway from the trunks of trees as possible. Tunneling under a large tree shall be considered as an alternative when it is anticipated that necessary trenching will destroy feeder roots. 12. Cleanup: KI Protective fencing shall be the last items removed during the final cleanup. 13. Damaged Trees: W Damaged trees shallI/l//}}��e treated immediately by pmning, fertilization or other methods recommended by a tree specialist. NOTE: IT IS THE DEVOPER'S RESPONSIBILITY TO CONFER WITH THE CONTRACTOR ON TREE CONSERVATION REQUIREMENTS. OWNER SIGNATURE iJi (DATE) CONTRACT PURCHASER SIGNATURE (DATE) 5/1/06 Page 1 of 1 I II I CONSERVATION PLAN NOTES: 1.ALL TREES TO BE PRESERVED AND PROTECTED SHALL BE MARKED WITH PAINT OR RIBBON AT A HEIGHT CLEARLY VISIBLE TO EQUIPMENT OPERATORS. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE TREE MARKING HAS BEEN INSTALLED BY THE CONTRACTOR AND INSPECTED AND APPROVED BY THE COUNTY ENGINEERING DEPARTMENT 2. HEAVY EQUIPMENT, VEHICULAR TRAFFIC, AND THE STORAGE OF CONSTRUCTION MATERIALS AND SOIL SHALL NOT BE PERMITTED WITHIN THE OUTSIDE DRIPLINE OF TREES TO BE PRESERVED AND PROTECTED. 3. TEMPORARY EROSION CONTROL MEASURED AND/OR PERMANENT STORMWATER MANAGEMENT FACILITIES LOCATIONS SHALL BE COORDINATED SUCH THAT THEY SHALL NOT ADVERSELY AFFECT TREES TO BE PRESERVED AND PROTECTED. 4. FIRES SHALL NOT BE PERMITTED WITHIN 100 FEET OF THE OUTSIDE DRIPLINE OF TREES TO BE PRESERVED AND PROTECTED. 5. TOXIC MATERIALS SHALL NOT BE STORED WITHIN 100 FEET OF THE OUTSIDE DRIPLINE OF TREES TO BE PRESERVED AND PROTECTED. 6. NO LAND DISTURBING ACTIVITY SHALL BEGIN UNTIL THE TREE PROTECTIVE FENCING HAS BEEN INSTALLED BY THE CONTRACTOR AND INSPECTED AND APPROVED BY THE COUNTY ENGINEERING DEPARTMENT. 7. WHEN TRENCHING FOR ANY KIND OF UNDERGROUND WATER, SEWER, ELECTRICAL, CABLE, TELEPHONE OR OTHER UTILITY SERVICE IS NECESSARY WITHIN THE LIMITS OF TREE PROTECTION OR BEYOND THE LIMITS OF CLEARING THE SEPARATION FROM THE TRUNKS OF TREES SHALL BE MAXIMIZED TO THE FURTHEST EXTENT POSSIBLE. TUNNELING SHALL BE REQUIRED WHEN DEEMED, BY THE COUNTY ENGINEER, THAT TRENCHING WILL SIGNIFICANTLY DAMAGE FEEDER ROOTS OF TREES TO BE PRESERVED AND PROTECTED. 8. ANY DAMAGE TO THE CROWN, TRUNK, OR ROOT SYSTEM OF ANY TREE TO BE PRESERVED AND PROTECTED SHALL BE REPAIRED IMMEDIATELY, IN ACCORDANCE WITH THE PRACTICES IN THE EROSION AND SEDIMENT CONTROL HANDBOOK. CARE FOR SERIOUS INJURIES SHALL BE PRESCRIBED BY A PROFESSIONAL FORESTER OR TREE SPECIALIST. 9. SOILS WHICH HAVE BEEN COMPACTED, OVER THE ROOT ZONES OF TREES TO BE PRESERVED AND PROTECTED, SHALL BE AERATED BY PUNCHING HOLES WITH AN IRON BAR EVERY 18" OVER THE ROOT ZONE. THE BAR SHALL BE DRIVEN 12" DEEP AND MOVED BACK AND FORTH IN EACH HOLE UNTIL SOIL IS LOOSENED. 10. TREE PROTECTIVE MEASURES SHALL BE THE LAST OF THE TEMPORARY EROSION CONTROL PLAN MEASURES REMOVED DURING THE FINAL CLEAN-UP. PROPOSED 2o' DRAINAGE AND _LANDSCAPING EASEMENT (LANDSCAPED BUFFER AREA) DB. PG. OTE: IF TREES RELOCATED WITHIN 5' OR LESS OF THE PROPERTY INES ADJACEN TO TMP901` A2, TMP9oF--F-42, TMPg-oF=F-43, OR MPgoF-F-44, T E DEVELOPER SHALL REMOVE THE TREES ON THE DJACENT PRO ERTIES. THE REMOVAL OF WILL BE a UBJECT TO TH EXISTING PROPERTY OW EWS WRI N APPROVAL. " ACSA PROPOSED WATER SCRIM FENCE o N LANDSCAPING WITHIN 15' FENCE � LANDSCAPE BUFFER THAT TANK ry "1 ALONG ABUTS ACSA WATER TANK TMP F-A2 PROPERTY q PROPERTY SHALL HAVE NIF ALBEMARLE COUNTY LINE SIMILAR LANDSCAPING TO SERVICE AUTHORITY WHAT WAS PLANTED WITH DB 3571 PG 272 THE LATEST AVON PARK 20' GRADING EASEMENT DB.3291 PG.607 CO -t w II I �I ICID PROPOSED 15 LANDSCAPING - L_�, STORAGE TANK SECURITY EASEMENT (LANDSCAPED PR0POSnE-D 10' FENCE IMPROVEMENTS PLAN BUFFER AREA) PROPOSED LANDSCAPE DB. PG. EASEMENT CG 2 CURB DB.PG. ' S53 4b09 E 114.92 o FRONT x S ETBA 20 PARKIN NO G �� _T_ I SIGN TYP. - R o EA SETBA K A I< EAR SE C :� R 5 I LOT 1 - I I - q 0 � C~ � W lo�� CS Soto CO w�co �o 00 o� r= o PROPOSED PRIVAT ACCESS EASEMEW DB.__PG. 5' REAR SETBACK 13 A4 15 16 I I i NOTE: ALL LANDSCAPING EASEMENTS, BUFFERS, AND SCREENING SHALL BE PLANTED IN ACCORDANCE WITH THE APPROVED PROFFERS. LANDSCAPING SHALL BE INSTALLED PRIOR TO THE FIRST CERTIFICATE OF OCCUPANCY FOR ANY PROPOSED UNITS WITHIN THE DEVELOPMENT AS DETAILED IN PROFFER 3. n PROPOSED 2o' LANDSCAPING EASEMENT - NATURAL LANDSCAPED AREA OR REPLANTING/NEW LANDSCAPED BUFFER FOR ANY DISTURBED AREAS DB. PG. LOCATION OF PROPOSED DETENTIO N BASIN Un � 'PROPOSED 20' S 24" CMP � IMPROVED ASPHALT EMERGENCY ACCESS DRIVEWAY - - EASEMENT ACCESS FOR (2) LOTS DB. PG. CONCRETE \\ ---- LOT 30 d� 37,445SF o.86 ACRES �� ASPHALT , CONC ETE � O I O O PLANTEF' EXISTING 28' I EASEMENT E/P - E/P DB. 32g1 PG. 607 D EXISTING 32' I F/C - F/C : I TMP 90E-7 TMP 90E-9 N/F IAN FARIS X O' CONNOR LIVING TMP 90E-8 DB 4163 PG 261 �O TRUST N/F IGNACIO 0 TARA L DE DB 5116 PG 289 CARDENAS T � � DB 4060 PG 77 THP 00-30R PROPOSE PROPOSED 1o' D SCRIM FENCE �- N11F JOHN A OR RUBY T BROOKS � T LANDSCAPING FENCE ALONG PROPERTY LINE RR 1191 PO 396 9 EASEMENT ADJACENT TO TMP goF-Ai. PROPOSED 5' DB. PG. PROPOSED 20 DRAINAGE AND LANDSCAPING COMMUNITY LANDSCAPING EASEMENT EASEMENT ASSOCIATION INC CIO PROPOSI (LANDSCAPED BUFFER AREA) DB.--PG. REAL PROPERTY INC LANDSCi S58° 8'07"E 4g5 7g DB. PG. DB 3692 PG 319 S31°02'03"W 3.10' - y DB. F S59°2 1'51 "E 370.96' r 1 O 0200 ' •2 0 PROPOSED EMERGENCY ACCESS ROAD REMOVABLE BOLLARDS 10 R AR SET ACK - - :P . ROPOSED 20 LANDSCAPING I I _ I t EASEMENT -NATURAL LANDSCAPED: 6 I ^ V 1 AREA NEW - - - OR REPLANTIN G N LOT I r I I O LOT O L I' OT LAND APED B FFER F R ANY SC U O N LOT LOT O .. ....• ..•..••. ::.::::::::::::::::."..:. •..::..:::::::•'::: 28 26 4 �... •... 2 f :::::ii •.. •.::.. DISTURBED AREAS - ;� 5 I LM IF- PG. B. o I ........................................................ •...... I in 12 x18 ASPHALT : TMP 9 D 31 �� \ 1 ' FR NT E 0 r� o O S TBACK �'•• o� .�•' / h C-, '. � 5.262 AC DRIVEWAY MIN. N OPEN PA \ 1 I I ARE AB o C-)\ - I of 2= 11 i w .T 9.2 I -0 / T - S OP SIGN TYP. S A 0 1 F - 5� 55 S .a 1%s / EXISTING S GGRAVEL s r 1 I 4 DRIVEWAY T BE I �. I O CONCRET . :::::::;::. ®1 I k i i r I SPHOALT DRIVEWAY I W PROPOSED I _ TO SERVE LOTS 29 I I LOT 30 c� W w DESOTO DRIVE ��' GUARDRAIL I �� LOT 29 AND30 I 37,445 II I I NOTE: SLOPE OF 40,020 SF I o.86 ACRES 49 RIVATE RIW I I EMERGENCYACCESS 0.92 ACRES I I 4 1 X ram+ I I ROAD SHALL NOT I I i I I EXCEED 16% I to I CONCRETE PROPOSED 20' I to ii I I EMERGENCYACCESS /7N zo RON SET ACK I A. EA EMENT - I S I - I DB. P Yz I G. nl I - 968 , I v - AR STREET F - 1 QI �4) 1 / CONIC ETE m TREES ALONG \ PROPOSED 12' / w DESOT0 DRIVE 0 \ \ ' ASPHALT EMERGENCY : \ :iii; i ul k _ - - - ACCESS ROAD - LOT LOT LOT LOT 2L T LOT :: • \ \ ---- _ _ _ - - - ��� O :� 0 OCD •.: •.: •. 3.8 19 ••.I••.'••.- ... •• -22 + PROPOSED 47 PRIVATE _ _ , GRAVE L00 :. ACCESS EASEMENT zo REAR PROPOSED CG-6"CURB-.' i NO PARKINGii SIGN (TYP.) (3) AR STREET (2) UA STREET N59°18'07"W 1,072.99'(T) TREES ALONG NO PARKING TREES ALONG TREES ALONG AREA A: 7,334 SF SIGN (TYP.) HATHAWAY DESOTO COURT PROPOSED 1o' LANDSCAPING ANOKO COURT STREET EASEMENT (LANDSCAPED PROPOSED 10' LANDSCAPING (3) AR STREET BUFFER AREA) (4) AR STREET PROPOSED DOUBLE -SIDED EASEMENT (LANDSCAPED (4) UA STREET TREES ALONG ------------------ DB.--PG. NOTE: SCRIM FENCING TO BE INSTALLED IMMEDIATELY FOLLOWING GRADING IN THE LOCATION WHERE THE SCRIM FENCE IS TO BE LOCATED. LANDSCAPING NOTES: 1. STREETTREES PROVIDED So' O.C. AND 5'-io' FROM PROPOSED UTILITIES. 2. ALL SITE PLANTINGS OF TREES AND SHRUBS SHALL BE ALLOWED TO REACH AND BE MAINTAINED AT, MATURE HEIGHT; THE TOPPING OF TREES IS PROHIBITED. SHRUBS AND TREES SHALL BE PRUNED MINIMALLY AND ONLY TO SUPPORT THE OVERALL HEALTH OF THE PLANT. 3. TOTAL STREET FRONTAGE = 964' REQUIRED STREET TREES: 21(1 TREE PER EVERY 56 OF STREET FRONTAGE) PROPOSED STREET TREES: 23 NOTE: 278' OF STREET FRONTAGE ALONG HATHAWAY STREET REQUIRED STREET TREES: 6 PROPOSED STREET TREES: 7 NOTE: 382' OF STREET FRONTAGE ALONG DESOTO DRIVE REQUIRED STREET TREES: 8 PROPOSED STREET TREES: 8 NOTE: 200' OF STREET FRONTAGE ALONG ANOKO COURT REQUIRED STREET TREES: 4 PROPOSED STREET TREES: 4 NOTE: 104' OF STREET FRONTAGE ALONG DESOTO COURT / REQUIRED STREET TREES: 3 PROPOSED STREET TREES: 4 4. PARKING LANDSCAPE REQUIREMENTS REQUIRED PARKING LANDSCAPING = 21 PARKING SPACES @a 1 TREE / 10 SPACES - = 3 TREES REQUIRED TOTAL TRESS PROVIDED ADJACENT TO PARKING SPACES = 3 TREES PROVIDED --5. SEE SHEET 6A FOR TREE PLANTING & STAKING AND TREE FENCING & ARMORING DETAILS. STREET TREES LANDSCAPING PLANT SCHEDULE SYM BOTANICAL COMMON NAME SIZE CANOPY (SF) TOTAL SITE QUANTITY COVERAGE (SF) AR ACER RUBRUM RED MAPLE 13/4" 397 14 5,558 UA ULMUS AMERICANA AMERICAN ELM 13/4" 397 12 4,764 I I 2o' GRADIN TREES ALONG TREES ALONG DESOTO COURT VERTICAL FENCING (BOARD BUFFER AREA) ANOKO COURT TMP 90-30 ON BOARD) PRIVACY FENCE DB. PG. HATHAWAY INCL. PARKING) (INCL. PARKING) N/F GARY D BROOKS JR ! I STREET DB 4858 PG 406 NOTE: ALL STREETS WITHIN THE DEVELOPMENT SHALL BE MARKED WITH NO PARKING SIGNS ON BOTH SIDES OF THE ROADWAY. HATHAWAY STREET SHALL BE MARKED WITH NO PARKING SIGNS ON ONE SIDE OF THE ROADWAY. / `PROPOSED 3 BOARD FARM FENCE ALONG PROPERTY LINE NOTE: (*) DENOTES THE LOCATI N OF THE AFFORDABLE UNIT WITHIN THE DEVELOPMENT. pEb PROFFER #1, THERE SHALL BE (6) AFFORDABLE HOUSING UNITS WITHIN THE DEVELOPMENT. AREA OF PROPOSED ONSITE LANDSCAPE BUFFER TMP 90-30A N/F GARY D OR MYRTLE T BROOKS DB 1191 PG 396 30 0 1o GRAPHIC SCALE 30 60 ( IN FEET ) 1 inch = 30 ft. THP 00-30R N11F JOITiN A OR RUBY T BROOKS RR 1191 PO 396 120 " 0� � SCOTT R. LLINS77' Lic. No. 035791 12/3/20 o��ssI ONAL ' 1SA � z z Zz o Q w � O O 1■�1 w lb � Q Q J w z o Q F LU W w > LU Ce 0 0 0 LU N N N �rn < M M QrN d� C'7 00 N co N O N N Q Zw w CO J� w J I- LU w w a � JOB NO. 112066 SCALE ill _ 30 1 SHEET NO. 3.6 6 z w w z 0 z w z J J O L) 0 C O U C N L Co 0 N Q 0 t a� a 0 U L 0 U 0 C c a 0 U 0 U 0 0 U C L 0 Co Co 0 Co L Q T 0 Co n 0 a U) Q L 0 0 _0 U 0 Q 0 E _0 a z w w z 0 z w <n z J J O O 0 Q 0 Q U X E 6 U 0 _0 -0 0 U 0 U) rn 0 T) 0 U) Q 0 Q) FC